FORTIFIER DIGITAL WRIST BLOOD PRESSURE MONITOR, MODEL LF-01

K041400 · Fortifier International Co., Ltd. · DXN · Aug 24, 2004 · Cardiovascular

Device Facts

Record IDK041400
Device NameFORTIFIER DIGITAL WRIST BLOOD PRESSURE MONITOR, MODEL LF-01
ApplicantFortifier International Co., Ltd.
Product CodeDXN · Cardiovascular
Decision DateAug 24, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1130
Device ClassClass 2

Intended Use

The device is a noninvasive blood pressure measurement system intended to measure the systolic and diastolic blood pressures and pulse rate of an adult individual, over age 18, at home by using a non-invasive technique in which an inflatable cuff is wrapped around the wrist. The cuff circumference is limited to be 5.25" – 7.75".

Device Story

Digital wrist blood pressure monitor; uses oscillometric method to measure systolic/diastolic blood pressure and pulse rate. Input: pressure oscillations sensed via closed air pipe system during cuff inflation/deflation. Processing: microcomputer automatically senses pulse signal characteristics; calculates blood pressure based on cuff pressure oscillating amplitude changes. Output: digital display of blood pressure and pulse rate. Used at home by adult patients. Healthcare providers use output to monitor patient blood pressure status. Benefits: provides convenient, non-invasive, self-administered blood pressure monitoring without need for stethoscope or manual Korotkov sound detection.

Clinical Evidence

Bench testing only. Compliance with EN 60601-1:1990 (electric safety), EN 1060-1/EN 1060-3 (non-invasive sphygmomanometers), EN 60601-1-2 (EMC), and ANSI/AAMI SP10-1992 (electronic/automated sphygmomanometers).

Technological Characteristics

Oscillometric measurement principle; microcomputer-based processing. Wrist cuff (5.25"–7.75"). Powered by internal battery. Complies with EN 60601-1, EN 1060-1/3, and ANSI/AAMI SP10-1992 standards.

Indications for Use

Indicated for adults over age 18 for noninvasive measurement of systolic/diastolic blood pressure and pulse rate at home via wrist cuff (5.25"–7.75" circumference).

Regulatory Classification

Identification

A noninvasive blood pressure measurement system is a device that provides a signal from which systolic, diastolic, mean, or any combination of the three pressures can be derived through the use of tranducers placed on the surface of the body.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ### KO41400 FORTIFIER INTERNATIONAL CO., LTD. No. 45, Jung Shan 1st Road, Jung Shan Chiu, 203, Keelung, Taiwan, ROC Tel: 886-2-24231179 Fax: 886-2-24269170 E-mail: ficl(@ms8.hinet.net દ્ધ 510(k) SUMMARY " FORTIFIER International Co., Ltd. Submitter's Name: No. 45, Jung Shan 1st Road, Jung Shan Chiu, 203, Keelung, Taiwan, ROC Tel: 886-2-24231179 Fax: 886-2-24269170 E-mail: ficl(@ms8.hinet.net Date summary prepared: Device Name: AUG 2 4 2004 FORTIFIER Digital Wrist Blood Pressure Monitor, LF-01 Proprietary Name: Common or Usual Name: NONINVASIVE BLOOD PRESSURE MEASUREMENT SYSTEM Classification Name: Blood Pressure Monitor, Class II, 21 CFR 870.1130 May 15, 2004 Indications for Use: The device is a noninvasive blood pressure measurement system intended to measure the systolic and diastolic blood pressures and pulse rate of an adult individual, over age 18, at home by using a non-invasive technique in which an inflatable cuff is wrapped around the wrist. The cuff circumference is limited to be 5.25" – 7.75". Description of the device: FORTIFIER Digital Wrist Blood Pressure Monitor, LF-01 uses the Oscillometric method to measure the blood pressure. The Oscillometric method is adopted clinically to measure the blood pressure recently. It is not needed to use the stethoscope, as in the traditional measuring method, to monitor the Korotkov sound when deciding the systolic or diastolic pressure. The Oscillometric method senses the vibrating signal via the closed air pipe system and utilizes the microcor.puter to automatically sense the characteristics of the pulse signal. Through simple calculation, clinically proven, the reading can reflect the accurate real blood pressure, and the systolic pressure is defined as the pressure when the cuff pressure oscillating amplitude begins to increase and the diastolic pressure as the pressure when the cuff pressure oscillating amplitude stops decreasing. {1}------------------------------------------------ Kovács ## FORTIFIER INTERNATIONAL CO., LTD. No. 45, Jung Shan 156 Road, Jung Shan Chiu, 203, Keelung, Taiwan, ROC Tel: 886-2-24231179 Fax: 886-2-24269170 E-mail: ficl(@ms8.hinet.net Performance Testing: Electric Safety Requirement Test Report of EN 60601-1:1990 & EN 1060-1/ EN1060-3, and EMC test report of EN 60601-1-2 ( EN 55011:1991 and EN 61000-4-2:1995) ANSI/AAMI SP10-1992 Electronic or Automated Sphygmomanometers Legally marketed device for substantial equivalence comparison: Eikon Automatic Digital Blood Pressure Monitor, HD-400M (K021239) Summary for substantial equivalence comparison: Same characteristics: intended use, technological characteristics, power supply, display, measuring range, accuracy, operating and storage environments. Different characteristics: memory, dimensions, and weight. As we can understand, the memory feature is to memorize the measurement data 1. taken previously and is related to the usage convenience, not to raise any safety or effectiveness hazard. - 2. The differences between dimensions and weight are related to the designing aspects. These differences are not to raise any safety or effectiveness aspect. They are decided to be substantially equivalent. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three bars extending from its wing, enclosed within a circle. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged around the upper portion of the circle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 AUG 2 4 2004 Dr. Jen Ke-Min. Fortifier International, Co., Ltd. c/o ROC Chinese-European Industrial No. 58, Fu-Chiun St. Hsin-Chu City CHINA (Taiwan) 300 ### Re: K041400 Trade Name: FORTIFIER Digital Wrist Blood Pressure Monitor, LF-01 Regulation Number: 21 CFR 870.1130 Regulation Name: Non-Invasive Blood Pressure Measurement System Regulatory Class: Class II (two) Product Code: DXN Dated: May 15, 2004 Received: May 26, 2004 Dear Dr. Ke-Min: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 - Dr. Jen Ke-Min Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4646. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Neil KP S Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # FORTIFIER INTERNATIONAL CO., LTD. No. 45, Jung Shan 1st Road, Jung Shan Chiu, 203, Keelung, Taiwan, ROC Fax: 886-2-24269170 Tel: 886-2-24231179 E-mail: ficl@ms8.hinet.net Applicant: _ FORTIFIER International Co., Ltd.. 510(k) Number ( if known): Device Name: Digital Wrist Blood Pressure Monitor, LF-01 #### ● Indications for use: The device is a noninvasive blood pressure measurement system intended to measure the systolic and diastolic blood pressures and pulse rate of an adult individual, over age 18, at home by using a non-invasive technique in which an inflatable cuff is wrapped around the wrist. The cuff circumference is limited to be 5.25" – 7.75". Prescription Use AND/OR Over-The-Counter Use (Part 21 CFR 801 Subpart D) (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Neil HP Style Fir BD2 (Division Sign-Off) Division of Cardiovascular Device 510(k) Number
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...