SYMCARE DIABETES MANAGEMENT PROGRAM

K083263 · Symcare Personalized Health Solutions, Inc. · NBW · Mar 13, 2009 · Clinical Chemistry

Device Facts

Record IDK083263
Device NameSYMCARE DIABETES MANAGEMENT PROGRAM
ApplicantSymcare Personalized Health Solutions, Inc.
Product CodeNBW · Clinical Chemistry
Decision DateMar 13, 2009
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1345
Device ClassClass 2
AttributesSoftware as a Medical Device

Intended Use

The SymCare Diabetes Management Program is intended for use in home settings to aid people with diabetes and healthcare professionals in the review, analysis and evaluation of historical blood glucose test results to support effective diabetes management. It is intended for use as an accessory to blood glucose meters with data management capabilities. This system is intended for use by people 18 years of age and older. The SymCare Diabetes Management Program is not intended to provide treatment decisions or to be used as a substitute for professional healthcare judgment. All patient medical diagnoses and treatment are to be performed under the supervision and oversight of an appropriate healthcare professional.

Device Story

System acts as online tool for diabetes management; facilitates communication between patients and healthcare professionals. Inputs: blood glucose readings from validated meters (e.g., LifeScan OneTouch Ultra/Ultra II) via Bluetooth-enabled Polymap Wireless Polytel GMA accessory to cellular phone. Data transmitted from phone to SymCare online database. Outputs: logbooks, line charts, bar charts, pie charts, and time-of-day analysis accessible via web browser. Used in home settings by patients and in clinical settings by healthcare providers. Assists in review/evaluation of historical glucose data to support management; does not provide treatment decisions.

Clinical Evidence

No clinical efficacy data provided. A usability study was conducted to evaluate human factors, comprehension of the system by doctors and patients, and ease of use. Results demonstrated appropriate human factors and system usability.

Technological Characteristics

Web-based software platform; connectivity via Bluetooth (Polymap Wireless Polytel GMA accessory) and cellular phone. Compatible with Windows, Mac, and Linux operating systems; supports Firefox, IE, Safari browsers. Data transmission validated for glucose readings, comments, time, and date. No specific hardware materials or sterilization required as it is a software/data management accessory.

Indications for Use

Indicated for people with diabetes aged 18 and older in home settings to assist patients and healthcare professionals in reviewing and evaluating historical blood glucose data for diabetes management.

Regulatory Classification

Identification

A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

Special Controls

*Classification.* Class II (special controls). The device, when it is solely intended for use as a drink to test glucose tolerance, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## 510(k) Summary | Date | March 9, 2008 | |--------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Contact | Rae Ann DeLay<br>Director, Quality, Regulatory and Health Care Compliance<br>SymCare Personalized Health Solutions, Inc.<br>200 Lawrence Drive<br>West Chester, PA 19380<br>Phone: (484) 686-4650<br>Email: rdelay@its.jnj.com. | | Device Name | SymCare Diabetes Management Program | | Common Name | Accessory to glucose test system | | Classification | 862.1345 - Glucose Test System - Class II<br>862.2100 - Calculator/Data Processing Module for Clinical Use – Class I | | Predicate Devices | <ul><li>MCT-Diabetes™ by MyCare Team Inc. cleared most recently via 510(k) K073699</li><li>Think Positive (t+) Diabetes Management System by e-San Limited cleared most recently via 510(k) K061328</li></ul> | | Device Description | The SymCare Diabetes Management Program (DMP) is an online tool that helps patients to manage their diabetes and communicate their blood glucose readings to their healthcare providers, healthcare providers manage their diabetes patient population, and insurance companies manage their diabetes patient and health care provider populations. The DMP enables a blood glucose meter to connect via a Bluetooth accessory, the Polymap Wireless | Polytel® GMA Glucose Meter Accessory (GMA), to a cellular phone. Once the mobile phone has gathered the data from the meter, it transmits the data to a centralized repository database. The data is analyzed to recognize health patterns, show trends, and offer personalized health information. Continued on next page Kor 3263 {1}------------------------------------------------ # 510(k) Summary, Continued | Indications | The SymCare Diabetes Management Program is intended for use in home<br>settings to aid people with diabetes and healthcare professionals in the review-<br>analysis and evaluation of historical blood glucose test results to support<br>effective diabetes management. It is intended for use as an accessory to blood<br>glucose meters with data management capabilities. This system is intended<br>for use by people 18 years of age and older. The SymCare Diabetes<br>Management Program is not intended to provide treatment decisions or to be<br>used as a substitute for professional healthcare judgment. All patient medical<br>diagnoses and treatment are to be performed under the supervision and<br>oversight of an appropriate healthcare professional. | |----------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Technological<br>Characteristics | The SymCare Diabetes Management Program, like the predicate devices, is<br>an internet-based software device. | | Nonclinical<br>Tests | Extensive software verification and validation testing was conducted and<br>demonstrated compliance to requirements and design specifications. | | Clinical Tests | A study to measure the usability of the SymCare DMP was conducted. The<br>study demonstrated:<br>• comprehension of the study doctors, medical team members, and<br>participants with the DMP,<br>• appropriate human factors related to the DMP, and<br>• ease of use of the DMP. | | Conclusions | In accordance with the Federal Food, Drug and Cosmetic Act and 21 CFR<br>Part 807, and based on the information provided in this premarket<br>notification, SymCare Personalized Health Solutions, Inc., concludes that the<br>new device, the SymCare Diabetes Management Program, is safe, effective<br>and substantially equivalent to the predicate devices as described herein. | . · : ・ {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a stylized eagle with three stripes forming its wing and tail feathers. The eagle is encircled by the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" in a circular arrangement. Food and Drug Administration 2098 Gaither Road Rockville MD 20850 MAR 1 3 2009 Symcare Personalized Health Solutions, Inc . c/o Rae Ann DeLay Director, Quality, Regulatory & Health Care Compliance 200 Lawrence Drive West Chester, PA 19380 Re: k083263 > Trade/Device Name: Symcare Diabetes Management Program Regulation Number: 21CFR 862.1345 Regulation Name: Glucose Test System Regulatory Class: Class II Product Code: NBW, JOP Dated: February 27, 2009 Received: March 2, 2009 Dear Ms. DeLay: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in Title 21, Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); and good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820). {3}------------------------------------------------ Page - 2 This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific information about the application of labeling requirements to your device, or questions on the promotion and advertising of your device, please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 594-3084. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part.1807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll the (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, Corg C. He Courtney C. Harper, Ph.D. Acting Director Division of Chemistry and Toxicology Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health 产品的技术的 {4}------------------------------------------------ ### Indication for Use #### 510(k) Number (if known): k083263 Device Name: SymCare Diabetes Management Program Indication For Use: The SymCare Diabetes Management Program is intended for use in home settings to aid people with diabetes and healthcare professionals in the review, analysis and evaluation of historical blood glucose test results to support effective diabetes management. It is intended for use as an accessory to blood glucose meters with data management capabilities. This system is intended for use by people 18 years of age and older. The SymCare Diabetes Management Program is not intended to provide treatment decisions or to be used as a substitute for professional healthcare judgment. All patient medical diagnoses and treatment are to be performed under the supervision and oversight of an appropriate healthcare professional. Prescription Use X (21 CFR Part 801 Subpart D) And/Or Over the Counter Use _ (21 CFR Part 801 Subpart C) ### (PLEASE DO NOT WRITE BELOW THIS LINE; CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Device Evaluation and Safety (OIVD) Ruth Chosler Division Sign-Off Office of In Vitro Diagnostic Device Evaluation and Safety 510(k) k 0 83263
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...