VivaChek™ Fad Blood Glucose Monitoring System, VivaChek™ Fad Smart Blood Glucose Monitoring System, VivaChek™ Fad Sync Blood Glucose Monitoring System

K222126 · Vivachek Biotech (Hangzhou) Co., Ltd. · NBW · Aug 16, 2024 · Clinical Chemistry

Device Facts

Record IDK222126
Device NameVivaChek™ Fad Blood Glucose Monitoring System, VivaChek™ Fad Smart Blood Glucose Monitoring System, VivaChek™ Fad Sync Blood Glucose Monitoring System
ApplicantVivachek Biotech (Hangzhou) Co., Ltd.
Product CodeNBW · Clinical Chemistry
Decision DateAug 16, 2024
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1345
Device ClassClass 2
AttributesPediatric

Indications for Use

VivaChek™ Fad Blood Glucose Monitoring System is comprised of the VivaChek™ Fad Blood Glucose Meter and the VivaChek™ Fad Blood Glucose Test Strips. VivaChek™ Fad Blood Glucose Monitoring System is intended to quantitatively measure the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared. VivaChek™ Fad Smart Blood Glucose Monitoring System is comprised of the VivaChek™ Fad Smart Blood Glucose Meter and the VivaChek™ Fad Blood Glucose Test Strips. VivaChek™ Fad Smart Blood Glucose Monitoring System is intended to quantitatively measure the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared. VivaChek™ Fad Sync Blood Glucose Monitoring System is comprised of the VivaChek™ Fad Sync Blood Glucose Meter and the VivaChek™ Fad Blood Glucose Test Strips. VivaChek™ Fad Sync Blood Glucose Monitoring System is intended to quantitatively measure the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared.

Device Story

System measures glucose in capillary whole blood via amperometric assay using glucose dehydrogenase (FAD-GDH). Blood sample drawn into test strip via capillary action; reaction produces electrical current proportional to glucose concentration. Meter displays plasma-equivalent results. Intended for home self-testing by patients with diabetes; single-patient use only. Includes meter and test strips; Smart/Sync models feature rechargeable lithium-ion batteries and USB ports, while base model uses CR2032 coin battery. Provides quantitative glucose readings to assist patients in monitoring diabetes control. Not for clinical or assisted-use settings.

Clinical Evidence

Lay user performance studies (n=567 for Fad; n=353 for Fad Smart) compared user-obtained results against YSI 2300 laboratory method. Accuracy: 100% of results within ±20% of reference. Extreme glucose study (n=105) confirmed performance at low/high ranges. Bench testing included precision, linearity (20-600 mg/dL), interference, hematocrit (20-70%), altitude (up to 10,413 ft), and environmental robustness.

Technological Characteristics

Electrochemical biosensor; amperometric detection; FAD-glucose dehydrogenase chemistry. Power: AAA battery (Fad), CR2032 coin cell (Smart), or rechargeable 3.7V 250mAh Li-polymer battery (Sync). Measurement range: 20-600 mg/dL. Hematocrit range: 20-70%. Connectivity: varies by model (Smart/Sync variants).

Indications for Use

Indicated for quantitative measurement of glucose in fresh capillary whole blood from fingertips; for home use by persons with diabetes to monitor glycemic control. Not for neonatal use, diagnosis, or screening. For single-patient, in vitro diagnostic use.

Regulatory Classification

Identification

A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

Special Controls

*Classification.* Class II (special controls). The device, when it is solely intended for use as a drink to test glucose tolerance, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD &amp; DRUG ADMINISTRATION # 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT ## I Background Information: A 510(k) Number K222126 B Applicant Vivachek Biotech (Hangzhou) Co., Ltd C Proprietary and Established Names VivaChek™ Fad Blood Glucose Monitoring System, VivaChek™ Fad Smart Blood Glucose Monitoring System, VivaChek™ Fad Sync Blood Glucose Monitoring System D Regulatory Information | Product Code(s) | Classification | Regulation Section | Panel | | --- | --- | --- | --- | | NBW | Class II | 21 CFR 862.1345 - Glucose Test System | CH - Clinical Chemistry | ## II Submission/Device Overview: A Purpose for Submission: New devices B Measurand: Glucose in capillary whole blood from fingertip C Type of Test: Quantitative amperometric assay, glucose dehydrogenase (FAD-GDH) Food and Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993-0002 www.fda.gov {1} K222126 - Page 2 of 14 ## III Intended Use/Indications for Use: ### A Intended Use(s): See Indication(s) for Use below. ### B Indication(s) for Use: **VivaChek™ Fad Blood Glucose Monitoring System** is comprised of the VivaChek™ Fad Blood Glucose Meter and the VivaChek™ Fad Blood Glucose Test Strips. VivaChek™ Fad Blood Glucose Monitoring System is intended to quantitatively measure the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared. **VivaChek™ Fad Smart Blood Glucose Monitoring System** is comprised of the VivaChek™ Fad Smart Blood Glucose Meter and the VivaChek™ Fad Blood Glucose Test Strips. VivaChek™ Fad Smart Blood Glucose Monitoring System is intended to quantitatively measure the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared. **VivaChek™ Fad Sync Blood Glucose Monitoring System** is comprised of the VivaChek™ Fad Sync Blood Glucose Meter and the VivaChek™ Fad Blood Glucose Test Strips. VivaChek™ Fad Sync Blood Glucose Monitoring System is intended to quantitatively measure the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. It is not intended for neonatal use or for the diagnosis of or screening for diabetes. This system is intended for self-testing outside the body (in vitro diagnostic use), and should only be used by a single person and should not be shared. ### C Special Conditions for Use Statement(s): OTC - Over The Counter - The meter and lancing device are for single patient use. Do not share them with anyone including other family members! Do not use on multiple patients. - Not for use on critically ill patients, patients in shock or in a hyperglycemic-hyperosmolar state with or without ketosis. - Not for use on patients with severe dehydration. - Not for use on patients that are severely hypotensive. - Not for neonatal use. - Not for Alternative Site Testing (AST). - Not for screening or diagnosis of diabetes mellitus. {2} - Do not use at altitudes above 10413ft (3174 meters) above sea level. - This meter is not intended for use in healthcare or assisted-use settings such as hospitals, physician offices, or long-term care facilities because it has not been cleared by FDA for use in these settings, including for routine assisted testing or as part of glycemic control procedures. Use of this meter on multiple patients may lead to transmission of Human Immunodeficiency Virus (HIV), Hepatitis C Virus (HCV), Hepatitis B Virus (HBV), or other bloodborne pathogens. ## D Special Instrument Requirements: VivaChek™ Fad Blood Glucose Meter VivaChek™ Fad Smart Blood Glucose Meter VivaChek™ Fad Sync Blood Glucose Meter ## IV Device/System Characteristics: ### A Device Description: The VivaChek™ Fad Blood Glucose Monitoring System, the VivaChek™ Fad Smart Blood Glucose Monitoring System, and the VivaChek™ Fad Sync Blood Glucose Monitoring System share the same device technology and the same intended use. Each of the device systems is comprised of a VivaChek™ Fad Blood Glucose Meter (Fad, Fad Smart, or Fad Sync, respectively) and VivaChek™ Fad Blood Glucose Test Strips (sold separately). The device systems differ in minor design features and certain user functions. The VivaChek™ Fad Blood Glucose Monitoring System contains a user-replaceable single 3.0V CR 2032 coin battery and a strip ejector button. The VivaChek™ Fad Smart and VivaChek™ Fad Sync Blood Glucose Monitoring Systems contain a non-serviceable rechargeable 3.7 Volt lithium ion battery, a micro USB port for recharging, and have minor differences in exterior meter materials and color. The following items are compatible with the device systems but are not included with the purchase of the meter and are available for purchase separately: - VivaChek™ Fad Control Solutions (Level 1, Level 2, and Level 3) - VivaChek™ Lancing Device and VivaChek™ Lancets (k220475). ### B Principle of Operation: The VivaChek™ Fad, VivaChek™ Fad Smart and VivaChek™ Fad Sync Blood Glucose Monitoring Systems are designed to quantitatively measure the glucose concentration in fresh capillary whole blood. The blood sample is pulled into the tip of the test strip through capillary action. The glucose measurement is based amperometry achieved through the electrical current caused by the reaction of the glucose with glucose dehydrogenase and a mediator of the test strip, producing a current that positively correlates to the glucose concentration in the blood sample. The system is calibrated to display plasma equivalent results. After the reaction time, the glucose concentration in the sample is displayed on the meter. K222126 - Page 3 of 14 {3} K222126 - Page 4 of 14 ## C Instrument Description Information 1. **Instrument Name:** VivaChek™ Fad Blood Glucose Meter VivaChek™ Fad Smart Blood Glucose Meter VivaChek™ Fad Sync Blood Glucose Meter 2. **Specimen Identification:** There is no sample identification function with this device. Samples are applied directly to the test strip as they are collected. 3. **Specimen Sampling and Handling:** Samples are to be tested immediately upon collection. 4. **Calibration:** The meters do not require calibration or coding by the user. The meters are automatically coded. 5. **Quality Control:** VivaChek™ Fad Control Solutions (Level 1, Level 2, and Level 3) are available for use with the system. Each test strip vial is printed with a control solution range, and the user is instructed to compare the control results with the expected control ranges printed on the strip vial. Users are given instructions on when to conduct control solution testing and to call customer service if repeat testing with control material is out of range. The control solutions are automatically recognized by the meter and the results marked as control results and are not included in the patient result averages. ## V Substantial Equivalence Information: A **Predicate Device Name(s):** TD-4183 Blood Glucose Monitoring System B **Predicate 510(k) Number(s):** K190579 {4} K222126 - Page 5 of 14 C Comparison with Predicate(s): | Device & Predicate Device(s): | K222126 | K222126 | K222126 | K190579 | | --- | --- | --- | --- | --- | | Device Trade Name | VivaChek™ Fad Blood Glucose Monitoring System | VivaChek™ Fad Smart Blood Glucose Monitoring System | VivaChek™ Fad Sync Blood Glucose Monitoring System | TD-4183 Blood Glucose Monitoring System | | General Device Characteristic Similarities | | | | | | Intended Use/Indications For Use | For the quantitative measurement of the glucose concentration in fresh capillary whole blood samples drawn from the fingertips. It is intended for use by persons with diabetes at home as an aid to monitor the effectiveness of diabetes control. | Same | Same | Same | | General Device Characteristic Differences | | | | | | Battery | CR 2032 3.0 V | Rechargeable 3.7 V lithium ion | Rechargeable 3.7 V lithium ion | 1.5V AAA | VI Standards/Guidance Documents Referenced: FDA Guidance document “Self-Monitoring Blood Glucose Test Systems for Over-the-Counter Use - Guidance for Industry and Food and Drug Administration Staff” (September 29, 2020) VII Performance Characteristics (if/when applicable): A Analytical Performance: Unless otherwise noted, the studies detailed below were performed with the VivaChek™ Fad Blood Glucose Monitoring System. The differences between the three meters in this submission {5} (VivaChek™ Fad, VivaChek™ Fad Smart and VivaChek™ Fad Sync) are minor design features, as described above in section IV. Therefore, the studies for the VivaChek™ Fad meter are representative of the performance of all device systems in this 510(k) submission. # 1. Precision/Reproducibility: # Repeatability precision (within-run precision): Within-run precision studies were performed using venous whole blood samples adjusted to 5 glucose concentration levels (i.e., Level 1: 30 to $50\mathrm{mg / dL}$ , Level 2: 51 to $110\mathrm{mg / dL}$ , Level 3: 111 to $150\mathrm{mg / dL}$ , Level 4: 151 to $250\mathrm{mg / dL}$ , and Level 5: 251 to $400\mathrm{mg / dL}$ ). Each sample was tested 10 times on each of 10 VivaChek™ Fad meters using 3 lots of VivaChek™ Fad Blood Glucose Test Strips for a total of 300 tests per glucose concentration. Results are summarized below: | Glucose Level (mg/dL) | Strip Lot | n | Mean (mg/dL) | SD (mg/dL) | %CV | | --- | --- | --- | --- | --- | --- | | Level 1 (30 to 50) | 1 | 100 | 38.9 | 1.6 | 4.0% | | | 2 | 100 | 39.3 | 1.5 | 3.9% | | | 3 | 100 | 38.7 | 1.7 | 4.5% | | | Pooled | 300 | 39.0 | 1.6 | 4.2% | | Level 2 (51 to 110) | 1 | 100 | 67.1 | 2.5 | 3.7% | | | 2 | 100 | 70.4 | 2.2 | 3.1% | | | 3 | 100 | 68.5 | 2.2 | 3.3% | | | Pooled | 300 | 68.7 | 2.7 | 3.9% | | Level 3 (111 to 150) | 1 | 100 | 127.0 | 3.3 | 2.6% | | | 2 | 100 | 124.6 | 3.1 | 2.5% | | | 3 | 100 | 127.1 | 3.5 | 2.8% | | | Pooled | 300 | 126.2 | 3.5 | 2.8% | | Level 4 (151 to 250) | 1 | 100 | 198.0 | 4.5 | 2.2% | | | 2 | 100 | 198.5 | 4.6 | 2.3% | | | 3 | 100 | 197.5 | 4.6 | 2.3% | | | Pooled | 300 | 198.0 | 4.6 | 2.3% | | Level 5 (251 to 400) | 1 | 100 | 321.3 | 8.8 | 2.7% | | | 2 | 100 | 319.1 | 8.6 | 2.7% | | | 3 | 100 | 326.0 | 9.9 | 3.0% | | | Pooled | 300 | 323.0 | 8.1 | 2.5% | # Intermediate Precision: Intermediate precision of the glucose measurement was evaluated using 3 lots of VivaChek™ Fad Blood Glucose Test Strips, 10 VivaChek™ Fad meters and 5 levels of glucose control solutions (i.e., Level 1: 30 to $50\mathrm{mg / dL}$ , Level 2: 51 to $110\mathrm{mg / dL}$ , Level 3: 111 to $150\mathrm{mg / dL}$ , Level 4: 151 to $250\mathrm{mg / dL}$ , and Level 5: 251 to $400\mathrm{mg / dL}$ ). Each sample level was measured once a day with each meter and each test strip lot for 10 days, for a total of 300 replicates per level. Results are summarized below: K222126 - Page 6 of 14 {6} | Glucose Level (mg/dL) | Strip Lot | n | Mean (mg/dL) | SD (mg/dL) | %CV | | --- | --- | --- | --- | --- | --- | | Level 1 (30 to 50) | 1 | 100 | 40.7 | 1.2 | 2.8% | | | 2 | 100 | 40.7 | 1.2 | 2.9% | | | 3 | 100 | 40.8 | 1.2 | 3.0% | | | Pooled | 300 | 40.7 | 1.2 | 2.9% | | Level 2 (51 to 110) | 1 | 100 | 70.0 | 2.1 | 3.0% | | | 2 | 100 | 70.3 | 1.9 | 2.7% | | | 3 | 100 | 70.0 | 2.1 | 3.0% | | | Pooled | 300 | 70.1 | 2.0 | 2.9% | | Level 3 (111 to 150) | 1 | 100 | 129.4 | 2.7 | 2.1% | | | 2 | 100 | 130.3 | 2.7 | 2.0% | | | 3 | 100 | 130.0 | 2.6 | 2.0% | | | Pooled | 300 | 129.8 | 2.7 | 2.1% | | Level 4 (151 to 250) | 1 | 100 | 199.1 | 4.0 | 2.0% | | | 2 | 100 | 199.3 | 4.1 | 2.1% | | | 3 | 100 | 199.0 | 3.9 | 2.0% | | | Pooled | 300 | 199.2 | 4.0 | 2.0% | | Level 5 (251 to 400) | 1 | 100 | 349.9 | 7.5 | 2.2% | | | 2 | 100 | 350.1 | 7.0 | 2.0% | | | 3 | 100 | 350.4 | 7.5 | 2.1% | | | Pooled | 300 | 349.9 | 7.3 | 2.1% | # 2. Linearity: A linearity study was conducted with 11 venous whole blood glucose concentration levels (20, 78, 136, 194, 252, 310, 368, 426, 484, 542, and $600\mathrm{mg / dL}$ ) as determined by the comparative method (YSI 2300 STAT PLUS Glucose and L-Lactate Analyzer). The results from the VivaChek™ Fad meter were compared with the values obtained from the comparator method. The results from the regression analysis are summarized below: | Test Strip Lot # | Slope | y-intercept | R2-value | | --- | --- | --- | --- | | Lot 1 | 0.9902 | 0.9574 | 0.9985 | | Lot 2 | 0.9954 | 0.4356 | 0.9989 | | Lot 3 | 0.9986 | 0.2892 | 0.9988 | | Combined | 0.9947 | 0.5607 | 0.9987 | The results of the study support the sponsor's claimed glucose measurement range of 20 to $600\mathrm{mg / dL}$ . If a sample is less than $20\mathrm{mg / dL}$ , the result is flagged by the meter as "LO". If a sample result is more than $600\mathrm{mg / dL}$ , the result is flagged by the meter as "HI". The low and high functions were validated and demonstrated to function as intended. K222126 - Page 7 of 14 {7} # 3. Analytical Specificity/Interference: Interference studies were performed to evaluate the effect of endogenous substances and common exogenous substances expected in the intended use population. The study was conducted using venous whole blood samples adjusted to 3 glucose levels (60, 120, and 250 mg/dL) as measured by the comparative method (YSI 2300 STAT PLUS Glucose and L-Lactate Analyzer). The adjusted blood glucose concentrations were separated into a control sample with no interferent added and a test sample containing one of 32 potentially interfering substances. The VivaChek™ Fad meter measurements were averaged and the bias between the test samples and the control samples was calculated. The highest concentrations at which no significant interference (defined by the sponsor as bias vs. control being greater than ± 4.8 mg/dL at &lt; 75 mg/dL and ± 8% at &gt; 75 mg/dL) effect was observed are presented in the table below: | Substance | Highest Concentration with No Significant Interference | | --- | --- | | Acetaminophen | 20 mg/dL | | Ascorbic acid | 6 mg/dL | | Conjugated Bilirubin | 50 mg/dL | | Unconjugated Bilirubin | 40 mg/dL | | Cholesterol | 500 mg/dL | | Creatinine | 15 mg/dL | | Dopamine | 20 mg/dL | | EDTA | 200 mg/dL | | Galactose | 60 mg/dL | | Gentisic acid | 27.8 mg/dL | | Reduced Glutathione | 92.9 mg/dL | | Hemoglobin | 20 g/dL | | Heparin | 8000 IU/L | | Ibuprofen | 50 mg/dL | | L-Dopa (Levo-Dopa) | 3 mg/dL | | Maltose | 480 mg/dL | | Mannitol | 1800 mg/dL | | Methyldopa | 10.5 mg/dL | | Salicylic acid | 60 mg/dL | | Sodium | 180 mmol/L | | Tolbutamide | 100 mg/dL | | Tolazamide | 40 mg/dL | | Triglycerides | 1500 mg/dL | | Uric Acid | 24 mg/dL | | Xylose | 6.25 mg/dL | | Sorbitol | 0.09mg/dL | | Lactose | 25 mg/dL | K222126 - Page 8 of 14 {8} | Substance | Highest Concentration with No Significant Interference | | --- | --- | | Tetracycline | 1.5 mg/dL | | Xylitol | 0.09 mg/dL | | Lactitol | 0.09 mg/dL | | Isomalt | 0.09 mg/dL | | Maltitol | 0.09 mg/dL | The sponsor included the following statements in the labeling: - Do not test your blood glucose during or soon after a xylose absorption test. Xylose in the blood can give inaccurate results with this meter. 4. **Assay Reportable Range:** 20 to 600 mg/dL glucose 5. **Traceability, Stability, Expected Values (Controls, Calibrators, or Methods):** **Traceability** The system is traceable to NIST SRM 917c glucose reference material. A method comparison study was performed using the candidate devices and YSI 2300 STAT PLUS Glucose and L-Lactate Analyzer as the comparative method (see section VII.C.3). **Test Strip Stability Testing** Open-vial and closed-vial test strip stability was assessed with accelerated and real-time studies. Protocols and acceptance criteria were reviewed and found acceptable. The labeling includes claims that the test strips are stable for 6 months after opening and 24 months unopened when stored between of 36 to 86°F (2 to 30°C) and 10 to 90% relative humidity. 6. **Detection Limit:** The reportable range for the device systems is 20 to 600 mg/dL. 7. **Assay Cut-Off:** Not applicable. 8. **Accuracy (Instrument):** Not applicable. 9. **Carry-Over:** Not applicable. K222126 - Page 9 of 14 {9} K222126 - Page 10 of 14 # B Comparison Studies: 1. Method Comparison with Predicate Device: Please refer to lay user performance study below in section VII.C3. 2. Matrix Comparison: Not applicable. # C Clinical Studies: 1. Clinical Sensitivity: Not applicable. 2. Clinical Specificity: Not applicable. 3. Other Clinical Supportive Data (When 1. and 2. Are Not Applicable): Method Comparison/Lay User Performance Study To assess the performance in the hands of the intended users, the sponsor performed two independent lay user performance studies with either the VivaChek™ Fad Blood Glucose Monitoring System or the VivaChek™ Fad Smart Blood Glucose Monitoring System. The VivaChek™ Fad Sync Blood Glucose Meter is similar in form and function to the VivaChek™ Fad Smart Blood Glucose Meter (as described above in section IV). Therefore, the lay user performance study for the VivaChek™ Fad Smart meter is applicable to the VivaChek™ Fad Sync meter. The performance of the VivaChek™ Fad Blood Glucose Monitoring System was evaluated in the hands of 567 intended users at 3 study sites. The performance of the VivaChek™ Fad Smart Blood Glucose Monitoring System was evaluated in the hands of 353 intended users at 3 study sites. The participants in both studies were provided with the device labeling in English, collected their own fingertip capillary sample, and performed a blood glucose measurement without additional training. The blood glucose results obtained by lay users were compared against the results obtained with a laboratory-based comparative method (YSI 2300 STAT PLUS Glucose and L-Lactate Analyzer). Results for the VivaChek™ Fad Blood Glucose Monitoring System are summarized below: | System Accuracy Results for Glucose Range | | | | | --- | --- | --- | --- | | Within ± 5% | Within ± 10% | Within ± 15% | Within ± 20% | | 317/567 | 490/567 | 558/567 | 567/567 | | (55.9 %) | (86.4 %) | (98.4 %) | (100 %) | {10} K222126 - Page 11 of 14 | Regression Analysis | | | | --- | --- | --- | | Slope | y-intercept | R²-value | | 0.9838 | 1.4030 | 0.9837 | Results for the VivaChek™ Fad Smart Blood Glucose Monitoring System are summarized below: | System Accuracy Results for Glucose Range | | | | | --- | --- | --- | --- | | Within ± 5% | Within ± 10% | Within ± 15% | Within ± 20% | | 197/353 (55.8 %) | 304/353 (86.1 %) | 348/353 (98.6 %) | 353/353 (100 %) | | Regression Analysis | | | | --- | --- | --- | | Slope | y-intercept | R²-value | | 0.9966 | -0.3409 | 0.9808 | ## Usability At the end of the lay-user studies, each participant was asked to complete a usability questionnaire regarding ease of understanding of information in the user manual and the ease of use when performing a blood glucose test. From the sponsor's analysis of the questionnaire responses, the participants were satisfied with the ease of operation following the instructions for use in the labeling and with their overall ability to conduct testing with the candidate device. ## Readability The results Flesch-Kincaid readability assessment demonstrated that the User Manual and the test strip package insert were written at an 8th grade level or less. ## Accuracy at Extreme Glucose Study An accuracy study was performed to evaluate the performance of the VivaChek™ Fad and Fad Smart Blood Glucose Monitoring Systems with 105 fingertip blood samples containing extreme glucose concentrations at the extreme lower and upper ends of the claimed glucose measuring range. Of the 105 blood samples, 29 samples were altered with glycolysis to obtain glucose concentrations $\leq 80\mathrm{mg/dL}$ and 18 samples were supplemented with additional glucose to obtain glucose concentrations $\geq 250\mathrm{mg/dL}$. Results on the candidate devices using 3 test strip lots were compared to the results obtained using the comparative method (YSI 2300 STAT PLUS Glucose and L-Lactate Analyzer) and are summarized below: {11} Results for the VivaChek™ Fad Blood Glucose Monitoring System are summarized below: | Glucose Levels | Accuracy Results for Extreme Glucose Study | | | | | --- | --- | --- | --- | --- | | | Within ± 5% | Within ± 10% | Within ± 15% | Within ± 20% | | Extreme Low (<80mg/dL) | 39/53 (73.6 %) | 51/53 (96.2 %) | 53/53 (100 %) | 53/53 (100 %) | | Extreme High (>250mg/dL) | 31/52 (59.6 %) | 44/52 (84.6 %) | 52/52 (100 %) | 52/52 (100 %) | Results for the VivaChek™ Fad Smart Blood Glucose Monitoring System are summarized below: | Glucose Levels | Accuracy Results for Extreme Glucose Study | | | | | --- | --- | --- | --- | --- | | | Within ± 5% | Within ± 10% | Within ± 15% | Within ± 20% | | Extreme Low (<80mg/dL) | 40/53 (75.5 %) | 52/53 (98.1 %) | 53/53 (100 %) | 53/53 (100 %) | | Extreme High (>250mg/dL) | 32/52 (61.5 %) | 43/52 (82.7 %) | 52/52 (100 %) | 52/52 (100 %) | D Clinical Cut-Off: Not applicable. E Expected Values/Reference Range: The sponsor includes the following in their labeling: Expected blood glucose values for people without diabetes: | Time | Normal plasma glucose range for adults without diabetes, mg/dL | | --- | --- | | Before breakfast (fasting) | < 100 | | 2 hours after a meal | <140 | Reference: American Diabetes Association; Standards of Medical Care in Diabetes—2023 Abridged for Primary Care Providers. Clin Diabetes 2 January 2023; 41 (1): 4–31. F Other Supportive Instrument Performance Characteristics Data: 1. Hematocrit Study The effect of hematocrit was evaluated with venous blood samples adjusted to hematocrit levels of 20 to 70 % (20, 25, 30, 35, 42, 50, 55, 60, 65, and 70 %) at five glucose levels (30 to K222126 - Page 12 of 14 {12} 50, 51 to 110, 111 to 150, 151 to 250, and 251 to 400 mg/dL). The results obtained with the device system were compared to those obtained with the comparator method (YSI 2300 analyzer). The results demonstrated acceptable performance of the candidate blood glucose monitoring systems across the claimed hematocrit range of 20 to 70%. ## 2. Altitude Study To evaluate the effects of altitude, a study was conducted using whole blood samples altered to achieve 15 glucose concentrations ranging from 50.2 to 540.5 mg/dL. Testing was conducted at 10,413 feet. The results of obtained with the device system were compared to those obtained with the comparator method (YSI 2300 analyzer). The results support the claims that the device systems function as intended at altitudes up to the claimed altitude of 10,413 feet. ## 3. System Operating Conditions Study To evaluate device performance over varying operating temperature and humidity conditions, venous whole blood samples were adjusted to 3 glucose levels (60 to 70, 100 to 200, and 300 to 400 mg/dL). Testing was conducted under 4 combinations of temperature and relative humidity (RH) including 113°F (45°C) and 41°F (5°C) each at 10% and 90% RH, and under the nominal condition of 73°F (23°C) at 40% RH. The results obtained with the candidate systems were compared to those obtained with the comparator method (YSI 2300 analyzer). The results support the claims in the labeling that the device systems can be used in conditions of 41 to 113°F (5 to 45°C) with relative humidity of 10 to 90%. ## 4. Sample Volume Study Venous blood samples were prepared at 3 glucose range intervals (50 to 65, 100 to 120, and 200 to 250 mg/dL) and were tested at different sample volumes (0.6, 0.7, and 0.8 µL). The results obtained with the device systems were compared to those obtained with the comparator method (YSI 2300 analyzer). The results support the claimed minimum sample volume of 0.8 µL for the device systems. The sponsor provided validation studies demonstrating that with blood volumes below 0.8 µL, the insufficient sample volume error message functioned as intended. ## 5. Flex Studies The following additional flex studies were performed with the device system: drop/shock, early test strip removal, intermittent sampling, sample outside measuring range, sample perturbation, shipping, used test strips and vibration testing. The results demonstrated that the performance of the device systems is robust under these conditions. ## 6. Infection Control Studies The device systems are intended for single-patient use only. Disinfection efficacy studies were performed on the external meter materials by an outside commercial laboratory to demonstrate complete inactivation of hepatitis B virus (HBV) with the chosen disinfectant Clorox Healthcare Bleach Germicidal Wipes (EPA Registration No. 67619-12). Robustness studies performed by the sponsor using each of the three device systems demonstrated that there was no change in the performance of the systems or in the external materials of the meters after 608 cycles of cleaning and disinfection using Clorox Healthcare Bleach Germicidal Wipes. The robustness studies were designed to simulate 5 years of K222126 - Page 13 of 14 {13} single-patient use. Labeling was reviewed for adequate instructions for the validated cleaning and disinfection procedures. 7. Electrical Safety and EMC Studies The sponsor provided documentation certifying that acceptable electrical safety and electromagnetic compatibility (EMC) testing had been performed and the device systems were found to be compliant. 8. Test Strip Lot Release Protocol The test strip lot release protocol and acceptance criteria were reviewed and found to be acceptable. VIII Proposed Labeling: The labeling supports the finding of substantial equivalence for this device. IX Conclusion: The submitted information in this premarket notification is complete and supports a substantial equivalence decision. K222126 - Page 14 of 14
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...