STRAUMANN CARES SCREW-RETAINED BRIDGE TITANIUM, STRAUMANN CARES DOLDER BAR TITANIUM
K112280 · Straumann USA · NHA · Nov 16, 2011 · Dental
Device Facts
Record ID
K112280
Device Name
STRAUMANN CARES SCREW-RETAINED BRIDGE TITANIUM, STRAUMANN CARES DOLDER BAR TITANIUM
Applicant
Straumann USA
Product Code
NHA · Dental
Decision Date
Nov 16, 2011
Decision
SESE
Submission Type
Special
Regulation
21 CFR 872.3630
Device Class
Class 2
Attributes
Therapeutic
Intended Use
Straumann® CARES® Screw-retained Bridge Titanium and Straumann® CARES® Dolder® Bar Titanium are indicated for use as bars and bridges that attach to dental implants (Straumann Regular Neck (RN) Ø4.8mm and Wide Neck (WN) Ø6.5mm) in the treatment of partially or totally edentulous jaws for the purpose of restoring chewing function. The Straumann® CARES® Screw-retained Bridge Titanium is available in different sizes and spans and can be fitted on 2 to 16 implants. The Straumann® CARES® Dolder® Bar Titanium is available in different sizes and spans and can be fitted on 2 to 16 implants.
Device Story
Dental restorative devices (screw-retained bridges and Dolder bars) fabricated from Titanium grade 4. Input: scan data from dental master model with implant analogs/scanbodies. Process: dental technician designs bar/bridge using Straumann CARES Visual CAD software; digital dataset transmitted via internet to central milling facility for CAM production. Output: custom-milled titanium bridge or bar. Used in dental laboratories/clinics; operated by dental technicians and dentists. Final restoration finished using standard laboratory techniques. Provides patient-specific implant-supported prosthetic foundation to restore chewing function.
Clinical Evidence
Bench testing only. Fatigue testing performed per ISO 14801:2007 and FDA guidance for endosseous dental implant abutments. Metal-ceramic bond testing performed per ISO 9693. All tests met or exceeded predicate device performance criteria.
Technological Characteristics
Material: Titanium, grade 4. Design: CAD/CAM (Straumann CARES Visual software). Manufacturing: Centralized milling. Connectivity: Internet-based data transfer for CAM production. Implant interface: Straumann RN Ø4.8mm and WN Ø6.5mm. Sterilization: Not specified (standard dental laboratory processing).
Indications for Use
Indicated for partially or totally edentulous patients requiring restoration of chewing function via dental implant-supported bars or bridges. Compatible with Straumann Regular Neck (RN) Ø4.8mm and Wide Neck (WN) Ø6.5mm implants. Bridge supports 2-16 implants; Dolder Bar supports 2-10 implants.
Regulatory Classification
Identification
An endosseous dental implant abutment is a premanufactured prosthetic component directly connected to the endosseous dental implant and is intended for use as an aid in prosthetic rehabilitation.
Special Controls
*Classification.* Class II (special controls). The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)
Predicate Devices
Straumann® CARES® Screw-retained Bridge and Straumann® CARES® Dolder® Bar (K101465)
Related Devices
K101465 — STRAUMANN CARES BRIDGE; STRAUMANN CARES DOLDER BAR · Institut Straumann AG · Dec 13, 2010
K201711 — CARES Screw - Retained Bars and Bridges (SRBB) · Medentika GmbH · Dec 8, 2020
Submission Summary (Full Text)
{0}------------------------------------------------
K//2280
NOV 16 2011
Image /page/0/Picture/1 description: The image shows the Straumann logo. The logo consists of a stylized graphic to the left of the word "straumann" in bold, sans-serif font. The graphic appears to be two parallel lines, each with three small squares within them.
## 510(k) Summary
#### 1. Applicant's Name and Address
Straumann US (on behalf of Institut Straumann AG) 60 Minuteman Rd. Andover, MA 01810 800-448-8168, ext 2513 Telephone Number: Fax Number: 978-747-0023 Contact Person: Elaine Alan Senior Regulatory Affairs Specialist
- 2. Date of Submission: August 8, 2011
### 3. Name of the Device
Straumann® CARES® Screw-retained Bridge Ti Trade Name: Straumann® CARES® Dolder® Bar Ti Common Name: Implant Bridge Classification Name: Endosseous Dental Implant Abutment Regulation Number: \$872.3630
- 4. Legally Marketed Device to which Equivalence is Claimed (Predicate Device)
- K101465, Straumann® CARES® Screw-retained Bridge and . Straumann® CARES® Dolder® Bar
#### 5. Description of the Device
Straumann CARES Screw-retained Bridge, Titanium (Ti) and Straumann CARES Dolder Bar Titanium (Ti) are dental restorative devices intended to be attached directly to dental implants by basal screws. Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti are designed with implant interfaces comparable to a single tooth abutment which are attached to a Straumann implant with prosthetic platforms Regular Neck (RN) Ø4.8mm and Wide Neck (WN) Ø6.5mm.
{1}------------------------------------------------
The implant positions and oral situation are recognized by a scan of a dental master model with implant analogs and scanbodies. Based on the scan data, the dental technician selects the proper implant interfaces and designs the bar or bridge according to a dentist's prescription. Once the Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti is designed the digital dataset is sent to Straumann CADCAM by internet connection where the bridge or bar is milled from a Titanium-based blank.
Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti allow for individual customization regarding function and esthetics. They attach directly to Straumann dental implants. The device is intended to be finished into a bridge or overdenture using standard dental laboratory techniques and materials. The devices are CADderived, CAM-produced and have a scanner as its data source.
The milling blanks used for the manufacture of Straumann CARES Screwretained Bridge Ti and Straumann CARES Dolder Bar Ti are manufactured from Titanium, grade 4, which is biocompatible for its intended use.
#### 6. Intended Use
Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti are indicated for use as bars and bridges that attach to dental implants (Straumann implant Regular Neck (RN) Ø4.8mm and Wide Neck (WN) Ø6.5mm) in the treatment of partially or totally edentulous jaws for the purpose of restoring chewing function.
The Straumann CARES Screw-retained Bridge Ti can be designed for specific patient sizes and spans that are attached to 2 to16 implants.
{2}------------------------------------------------
The Straumann CARES Dolder Bar Ti can be designed for specific patient sizes and spans that are attached to 2 to 10 implants.
### 7. Technological Characteristics
The Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti are equivalent to the predicate device in design, fundamental operating principles, and intended use. Table 1 compares the Straumann CARES Screw-retained Bridge and Straumann CARES Dolder Bar to the predicate device. The proposed devices are milled from blank discs of Titanium, grade 4, which is widely used in the medical industry and is well known to be biocompatible. The Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti are designed using Straumann's CAD designing software, Straumann CARES® Visual®, and CAM milled at Straumann's central milling centers. This is the identical CADCAM designing and milling process as the predicate device.
## Table 1: Comparison Matrix
| Feature | Proposed Device<br>Straumann CARES Screw-retained<br>Bridge Ti and<br>Straumann CARES Dolder Bar Ti | Predicate Device<br>Straumann CARES Screw-retained<br>Bridge and<br>Straumann CARES Dolder Bar |
|---------------|-----------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| 510(k) Number | Subject Submission | K101465 |
| Intended Use | Same | The Straumann® CARES® Screw-<br>retained Bridge and Straumann®<br>CARES® Dolder® Bar are indicated<br>for use as bars and bridges that<br>attach to dental implants (Straumann<br>Regular Neck (RN) Ø4.8mm and<br>Wide Neck (WN) Ø6.5mm) in the<br>treatment of partially or totally<br>edentulous jaws for the purpose of<br>restoring chewing function.<br><br>The Straumann CARES® Screw-<br>retained Bridge is available in<br>different sizes and spans and can be<br>fitted on 2 to 16 implants.<br><br>The Straumann CARES Dolder Bar |
{3}------------------------------------------------
| Feature | Proposed Device | Predicate Device |
|--------------------------|----------------------------------------------------------------------------------|----------------------------------------------------------------------------|
| | Straumann CARES Screw-retained<br>Bridge Ti and<br>Straumann CARES Dolder Bar Ti | Straumann CARES Screw-retained<br>Bridge and<br>Straumann CARES Dolder Bar |
| Material | Titanium, grade 4 | Coron, Cobalt-Chromium alloy |
| Implant<br>Compatibility | same | Straumann Regular Neck (RN)<br>Ø4.8mm and Wide Neck (WN)<br>Ø6.5mm |
| Design<br>Software | Same | Straumann CARES Visual |
| Basal Screw | Same | Titanium Alloy, Ti6Al7Nb |
The proposed devices are substantially equivalent to the currently marketed predicate devices.
### 8. Performance Testing
Verification and validation testing were performed to ensure that the devices subject to this 510(k) Premarket Notification function as intended and that design input matches design output. Testing included:
- 1. Performance Testing
- i. Fatigue Testing was performed utilizing pertinent testing procedures defined in the FDA guidance document "Class II Special Controls Guidance Document: Root-form Endosseous Dental Implants and Endosseous Dental Implant Abutments," and ISO 14801:2007, "Dentistry-Implants-Dynamic fatigue test for endosseous dental implants." Table 2 lists tests performed and results.
| Test Performed | Acceptance Criteria | Result |
|------------------------|------------------------------------|--------|
| Minimal body testing | Meet or Exceed<br>Predicate Device | Passed |
| Free hanging bridge | Meet or Exceed<br>Predicate Device | Passed |
| Free end pontic bridge | Meet or Exceed<br>Predicate Device | Passed |
## Table 2
{4}------------------------------------------------
- ii. Metal-Ceramic bond testing in accordance with ISO 9693: Metal-ceramic dental restorative systems: requirements satisfied.
### Conclusion 9.
The results from the testing conducted demonstrated that the Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti functions as intended and met the pre-determined acceptance criteria.
The Straumann CARES Screw-retained Bridge Ti and Straumann CARES Dolder Bar Ti is a validated device. The results of the performance bench testing and risk analysis indicate that the Straumann CARES Screwretained Bridge Ti and Straumann CARES Dolder Bar Ti is substantially equivalent to the identified predicate device and is safe and effective for its intended use.
{5}------------------------------------------------
Image /page/5/Picture/0 description: The image shows the text "DEPARTMENT OF HEALTH & HUMAN SERVICES". The text is in all caps and is black. The text is likely part of a document or presentation.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
NOV 1 6 2011
Ms.Elaine Alan Senior Regulatory Affairs Specialist Straumann USA 60 Minuteman Road Andover, Massachusetts 01810 `
Re: K112280
Trade/Device Name: Straumann® CARES® Screw-retained Bridge Titanium Straumann® CARES® Dolder® Bar Titanium Regulation Number: 21 CFR 872.3630 Regulation Name: Endosseous Dental Implant Abutment Regulatory Class: II Product Code: NHA Dated: October 14, 2011 Received: October 17, 2011
Dear Ms. Alan:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{6}------------------------------------------------
## Page 2 – Ms. Alan
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
for
Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
### Enclosure
{7}------------------------------------------------
K/12280
# Indications for Use
510(k) Number (if known):
Device Name: Straumann® CARES® Screw-retained Bridge Titanium Straumann® CARES® Dolder® Bar Titanium
Indications for Use:
The Straumann® CARES® Screw-retained Bridge Titanium and Straumann® CARES® Dolder® Bar Titanium are indicated for use as bars and bridges that attach to dental implants (Straumann Regular Neck (RN) Ø4.8mm and Wide Neck (WN) Ø6.5mm) in the treatment of partially or totally edentulous jaws for the purpose of restoring chewing function.
The Straumann® CARES® Screw-retained Bridge Titanium is available in different sizes and spans and can be fitted on 2 to 16 implants.
The Straumann® CARES® Dolder® Bar Titanium is available in different sizes and spans and can be fitted on 2 to 10 implants.
X Prescription Use (Part 21 CFR 801 Subpart D) AND/OR
Over-the-Counter Use (21 CFR 801 Subpart C)
## PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED
Concurrence of DCRH, Office of Device Evaluation (ODE)
Susan Turner
Page 1 of 1
(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices
510(k) Number: K112081
510(k): Straumann SRBB Titanium
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.