Last synced on 10 May 2024 at 11:05 pm

Bone Grafting Material, Human Source

Page Type
Product Code
Definition
INTENDED TO BE PACKED INTO BONY VOIDS OR GAPS TO FILL AND/OR AUGMENT DENTAL INTRAOSSEOUS, ORAL AND CRANIO-/MAXILLOFACIAL DEFECTS. THESE DEFECTS MAY BE SURGICALLY CREATD OSSEOUS DEFECTS OR OSSEOUS DEFECTS CREATED FROM TRAUMATIC INJRY TO THE BONE, INLCUDING PERIODENTA/INFRABONY DEFECTS; ALVEOLAR RIDGE AUGMENTATION (SINUSOTOMY, OSTEOTOMY, CYSTECTOMY); DENTAL EXTRACTION SITES (RIDGE MAINTENANCE, IMPLANT PREPARATION/PLACEMENT); SINUS LIFTS; CYSTIC DEFECTS; CRANIOFACIAL AUGMENTATION.
Regulation Medical Specialty
Dental
Review Panel
Dental
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
872.3930
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
Yes
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 872.3930 Bone grafting material

§ 872.3930 Bone grafting material.

(a) Identification. Bone grafting material is a material such as hydroxyapatite, tricalcium phosphate, polylactic and polyglycolic acids, or collagen, that is intended to fill, augment, or reconstruct periodontal or bony defects of the oral and maxillofacial region.

(b) Classification. (1) Class II (special controls) for bone grafting materials that do not contain a drug that is a therapeutic biologic. The special control is FDA's “Class II Special Controls Guidance Document: Dental Bone Grafting Material Devices.” (See § 872.1(e) for the availability of this guidance document.)

(2) Class III (premarket approval) for bone grafting materials that contain a drug that is a therapeutic biologic. Bone grafting materials that contain a drug that is a therapeutic biologic, such as biological response modifiers, require premarket approval.

(c) Date premarket approval application (PMA) or notice of product development protocol (PDP) is required. Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.

[70 FR 21949, Apr. 28, 2005]

Bone Grafting Material, Human Source

Page Type
Product Code
Definition
INTENDED TO BE PACKED INTO BONY VOIDS OR GAPS TO FILL AND/OR AUGMENT DENTAL INTRAOSSEOUS, ORAL AND CRANIO-/MAXILLOFACIAL DEFECTS. THESE DEFECTS MAY BE SURGICALLY CREATD OSSEOUS DEFECTS OR OSSEOUS DEFECTS CREATED FROM TRAUMATIC INJRY TO THE BONE, INLCUDING PERIODENTA/INFRABONY DEFECTS; ALVEOLAR RIDGE AUGMENTATION (SINUSOTOMY, OSTEOTOMY, CYSTECTOMY); DENTAL EXTRACTION SITES (RIDGE MAINTENANCE, IMPLANT PREPARATION/PLACEMENT); SINUS LIFTS; CYSTIC DEFECTS; CRANIOFACIAL AUGMENTATION.
Regulation Medical Specialty
Dental
Review Panel
Dental
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
872.3930
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
Yes
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 872.3930 Bone grafting material

§ 872.3930 Bone grafting material.

(a) Identification. Bone grafting material is a material such as hydroxyapatite, tricalcium phosphate, polylactic and polyglycolic acids, or collagen, that is intended to fill, augment, or reconstruct periodontal or bony defects of the oral and maxillofacial region.

(b) Classification. (1) Class II (special controls) for bone grafting materials that do not contain a drug that is a therapeutic biologic. The special control is FDA's “Class II Special Controls Guidance Document: Dental Bone Grafting Material Devices.” (See § 872.1(e) for the availability of this guidance document.)

(2) Class III (premarket approval) for bone grafting materials that contain a drug that is a therapeutic biologic. Bone grafting materials that contain a drug that is a therapeutic biologic, such as biological response modifiers, require premarket approval.

(c) Date premarket approval application (PMA) or notice of product development protocol (PDP) is required. Devices described in paragraph (b)(2) of this section shall have an approved PMA or a declared completed PDP in effect before being placed in commercial distribution.

[70 FR 21949, Apr. 28, 2005]