SPI EASY DENTAL IMPLANT ABUTMENT

K023645 · Thommen Medical AG · NHA · Nov 13, 2002 · Dental

Device Facts

Record IDK023645
Device NameSPI EASY DENTAL IMPLANT ABUTMENT
ApplicantThommen Medical AG
Product CodeNHA · Dental
Decision DateNov 13, 2002
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 872.3630
Device ClassClass 2
AttributesTherapeutic

Intended Use

Thommen SPI® EASY Dental Implant Abutments are intended to be used in conjunction with SP1® System dental implants in the maxillary and/or mandibular arch to provide support for crowns, bridges or overdentures.

Device Story

SPI® EASY Dental Implant Abutments are endosseous components used in dental restorative procedures. Fabricated from commercially pure grade titanium, these abutments connect to SP1® System dental implants to support crowns, bridges, or overdentures. The device is intended for cemented restorations. The modification introduces additional lengths (4.3 mm and 7.0 mm) of straight abutments to existing diameters to reduce the need for clinical preparation. Used by dental clinicians in a clinical setting, the abutments provide a stable interface for prosthetic restorations, potentially improving patient oral function and aesthetics.

Clinical Evidence

bench testing only

Technological Characteristics

Material: Commercially pure grade 4 titanium (ASTM F67, ISO 5832-2). Form factor: Endosseous dental implant abutments, straight and 20° angulated, various diameters and lengths (4.3 mm to 9.0 mm). Connectivity: Mechanical interface with SPI® System and SPI® ONETIME implants. Sterilization: Non-sterile (sold as such).

Indications for Use

Indicated for patients requiring dental restoration in the maxillary or mandibular arch, specifically to provide support for crowns, bridges, or overdentures via connection to SP1® System dental implants.

Regulatory Classification

Identification

An endosseous dental implant abutment is a premanufactured prosthetic component directly connected to the endosseous dental implant and is intended for use as an aid in prosthetic rehabilitation.

Special Controls

*Classification.* Class II (special controls). The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Page 1 of 2 KO23645 ## ADMINISTRATIVE INFORMATION . | Manufacturer Name: | Thommen Medical AG<br>Hauptstrasse 87<br>CH-4437 Waldenburg<br>Switzerland<br>Telephone +41 61 965 90 20<br>FAX +41 61 965 90 21 | NOV 1 3 2002 | |----------------------------|----------------------------------------------------------------------------------------------------------------------------------|--------------| | Official Contact: | Orlando Antunes | | | Representative/Consultant: | Floyd G. Larson<br>PaxMed International<br>4329 Graydon Road | | San Diego, CA 92130 Telephone (858) 792-1235 FAX (858) 792-1236 #### DEVICE NAME | Classification Name: | Abutment, Implant, Dental, Endosseous (NHA) | |-------------------------|---------------------------------------------| | Trade/Proprietary Name: | SPI® EASY Dental Implant Abutment | | Common Name: | Endosseous Dental Implant Abutment | ESTABLISHMENT REGISTRATION NUMBER Thommen Medical AG has submitted an Establishment Registration to FDA. The Establishment Registration number has not yet been assigned. The Owner/Operator number is 9051144. #### DEVICE CLASSIFICATION FDA has classified endosseous dental implants as a Class III device (21 CFR 872.3640). The product code for "Abutment, Implant, Dental, Endosseous" is NHA. #### CONFORMANCE WITH PERFORMANCE STANDARDS No performance standards applicable to endosseous dental implant abutments have been established by FDA. However, the CP titanium Grade 4 used to manufacture Thommen dental implant abutments meets the chemical and mechanical requirements of ASTM F67 and ISO 5832-2. #### PREDICATE DEVICE INFORMATION The predicate device for this modification is the HA-Ti Dental Implant System, cleared by FDA on January 4, 1991 under K901927 and July 12, 2001 under K003045. Thommen Medical AG has acquired the rights to the HA-Ti Dental Implant System from HATI Dental AG and has renamed it the SP18 Dental Implant System. {1}------------------------------------------------ ### PACKAGING/LABELING/PRODUCT INFORMATION Thommen SPI® EASY Dental Implant Abutments will be packaged and sold non-sterile. The device is not represented to be "pyrogen free." Samples of product labels are shown in Exhibit II, with copies of the prosthetic procedure manual with the instructions for use. All catalogues will be amended to include the modified devices, consistent with the information shown for existing devices. ## INTENDED USE Thommen SPI® EASY Dental Implant Abutments are intended to be used in conjunction with SP10 System dental implants in the maxillary and/or mandibular arch to provide support for crowns, bridges or overdentures. ### DEVICE DESCRIPTION Thommen SPI® EASY Dental Implant Abutments are endosseous dental implant abutments made of commercially pure grade titanium and intended for cemented restorations. They may be used for cemented single crowns or bridges. The existing abutments are offered in four diameterswith lengths from 6.0 mm to 9.0 mm. Straight abutments and abutments with angulation correction of 20° are available. The preangled abutments are also available in the four diameters, with lengths from 6.5 mm to 9.0 mm The SPI® EASY abutments added by means of this Special 510(k) all are straight abutments and include lengths of 4.3 mm and 7.0 mm in each of the existing diameters. The shorter abutments are intended to reduce or eliminate the need for the clinician to prepare the abutment for restoration. All SPI® EASY abutments may be used with allSPI® ELEMENT implants (those covered in the HA-Ti predicate device submissions referred to above), as well as withSPI® ONETIME implants, covered by Thommen Medical AG Special 510(k) K022038. ## EQUIVALENCE TO MARKETED PRODUCT The modified SP10 EASY Dental Implant Abutment has the following similarities to the predicate SP1® System and HA-Ti Dental Implant Abutments: - has the same intended use, - uses the same operating principle, 트 - I incorporates the same basic design, - . incorporates the same materials, and - . is packaged and sterilized using the same materials and processes. In summary, the modified Thommen SPI® EASY Dental Implant Abutment described in this submission is, in our opinion, substantially equivalent to the predicate devices. {2}------------------------------------------------ ### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is circular, with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the top half of the circle. Inside the circle is a stylized image of a human figure, with three overlapping profiles facing to the right. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 NOV 1 3 2002 Thommen Medical AG C/O Mr. Floyd G. Larson PaxMed International 4329 Graydon Road San Diego, California 92130 Re: K023645 Trade/Device Name: SPI® EASY Dental Implant Abutment Regulation Number: 21 CFR 872.3640 Regulation Name: Endosseous Implant Regulatory Class: III Product Code: DZE and NHA Dated: October 28, 2002 Received: October 30, 2002 Dear Mr. Larson: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA). it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ #### Page 2 - Mr. Larson Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Patacia Ciccutti for Timothy A. Ulatowski Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health {4}------------------------------------------------ # Special 510(k): Device Modification ## SPI® EASY Dental Implant Abutments Applicant: Thommen Medical AG 510(k) Number: K023645 Device Name: SPI® EASY Dental Implant Abutment Indications for Use: Thommen SPI® EASY Dental Implant Abutments are intended to be used in conjunction with SP1® System dental implants in the maxillary and/or mandibular arch to provide support for crowns, bridges or overdentures. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NECESSARY ) ============================================================================================================================================================================== Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use OR Over-The-Counter Use Susan Purpura (Division Sign-Off) Division of Anesthesiology, General Hospital, Infection Control, Dental Devices 510(k) Number: .
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...