GLOVE, PATIENT EXAMINATION, VINYL (POWDERED)

K964321 · Shijiazhuang Hongray Plastic Products Co., Ltd. · LYZ · Jan 9, 1997 · General Hospital

Device Facts

Record IDK964321
Device NameGLOVE, PATIENT EXAMINATION, VINYL (POWDERED)
ApplicantShijiazhuang Hongray Plastic Products Co., Ltd.
Product CodeLYZ · General Hospital
Decision DateJan 9, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.6250
Device ClassClass 1

Indications for Use

A glove is worn on the hand of healthcare and similar personnel to prevent contamination between healthcare personnel and the patient's body, fluids, waste or environment.

Device Story

Vinyl patient examination glove; ambidextrous; prepowdered. Worn by healthcare personnel to provide a protective barrier against contamination. Device acts as a physical barrier between the wearer and patient fluids/waste. No electronic, software, or algorithmic components.

Clinical Evidence

No clinical data. Biocompatibility testing performed including primary dermal irritation in rabbits and Guinea Pig sensitization (Buehler). Bench testing conducted per ASTM D5250 and FDA water leak test (pinhole rate <4%).

Technological Characteristics

Vinyl material; prepowdered; ambidextrous; 10-inch length. Thickness: 0.08mm (finger), 0.09mm (cuff), 0.15mm (palm). Tensile strength min 10.0 MPa; elongation min 350%. Meets ASTM D5250 and JIS-S-2045 standards.

Indications for Use

Indicated for use by healthcare and similar personnel as a protective barrier to prevent cross-contamination between the wearer and the patient's body, fluids, waste, or environment.

Regulatory Classification

Identification

A non-powdered patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. A non-powdered patient examination glove does not incorporate powder for purposes other than manufacturing. The final finished glove includes only residual powder from manufacturing.

Related Devices

Submission Summary (Full Text)

{0} K964321 H-RAY JAN - 9 1997 # ShiJiaZhuang HongRay Plastic Products Co., Ltd. HEAD OFFICE NO. 135 XIN HUA WEST ROAD, SHIJIAZHUANG CITY, &amp; FACTORY HEBEI PROVINCE, CHINA P.O. BOX, 050081 TEL. 86 311-334449 334221 BRANCH OFFICE, RM3, 5TH FL., NO. 76 FUSHING SOUTH ROAD, SECTION I, TAIPEI, TAIWAN P.O. BOX, 53-186, TAIPEI TEL. 886-2-7720306-7 7110338 7217339 FAX. 886-2-7712601 TELEX. 22602 KENAN OUR REF. 510(K) SUMMARY - K964321 1.0 APPLICANT: MR. LIN CHIN YU SHIJIAZHUANG HONGRAY PLASTIC PRODUCTS CO., LTD. NO. 135 XIN-HUA WEST RD. SHIJIAZHUANG, CHINA TEL. 886 2 772-0306-7 FAX. 886 2 771-2601 2.0 CONTACT PERSON MR. LIN CHIN YU SHIJIAZHUANG HONGRAY PLASTIC PRODUCTS NO. 135 XIN-HUA WEST RD. SHIJIAZHUANG, CHINA TEL. 886 2 772-0306-7 FAX. 886 2 771-2601 AGENT: MR. DON MORRIS 14 LEEWARD ISLAND CLEARWATER, FL. 34630 USA TEL. 800-366-9545 FAX. 813-443-3482 3.0 Device Class: 1 Product Code: 80LYZ 4.0 Specification: Glove, Patient Examination, Vinyl (Powdered) meets all of the requirements of ASTM Standard D5250 5.0 Device Description: Glove, Patient Examination, Vinyl (Powdered) 6.0 Intended Use: A glove is worn on the hand of healthcare and similar personnel to prevent contamination between healthcare personnel and the patient's body, fluids, waste or environment. 7.0 Inner Surface: Prepowdered 8.0 Biocompatibility Testing: Primary Dermal Irritation in Rabbits and Guinea Pig Sensitization (Buehler) by Consumer Products Testing Co., USA. {1} H-RAY Shijiazhuang HongRay Plastic Products Co., Ltd. HEAD OFFICE NO. 135 XIN HUA WEST ROAD, SHIJIAZHUANG CITY, K. FACTORY ' HEBEI PROVINCE, CHINA P.O. BOX, 050081 TEL. 86 311-334449 334221 BRANCH OFFICE, RM3, 5TH FL., NO. 76 FUSHING SOUTH ROAD, SECTION I, TAIPEI, TAIWAN P.O. BOX, 53-186, TAIPEI TEL. 886-2-7720306-7 7110338 7217339 FAX. 886-2-7712601 TEL.EX, 22602 KENAN YOUR REF. 510(K) SUMMARY Page 2 of 2 ## 9.0 Quality Characteristics SPECIFICATION OF VINYL GLOVES (ANBIDEXTROUS) POWDER 10" | SIZE SPEC | SMALL | MEDIUM | LARGE | X-LARGE | TEST CODE | | --- | --- | --- | --- | --- | --- | | CIRCUMFERENCE OF PALM (M/M) (INCH) | 178 6-3/4 | 210 7-3/4 | 218 8-1/2 | 230 9 | JIS-S-2045.5.9 | | TOTAL LENGTH (±5M/M) | 240 | 245 | 245 | 245 | JIS-S-2045.5.9 | | LNGTH OF FINGERS (M/M) THUMBS | 55 | 57 | 61 | 63 | JIS-2045.5.9 | | INDEX FINGER | 66 | 70 | 75 | 78 | | | MIDDLE FINGER | 74 | 81 | 88 | 92 | | | RING FINGER | 69 | 74 | 79 | 82 | | | LITTLE FINGER | 54 | 55 | 60 | 62 | | | CIRCUMFERENCE FINGERS THUMB | 63 | 71 | 78 | 83 | JIS-S-2045.5.9 | | INDEX FINGER | 56 | 64 | 70 | 74 | | | MIDDLE FINGER | 59 | 66 | 72 | 76 | | | RING FINGER | 56 | 63 | 69 | 73 | | | LITTLE FINGER | 50 | 57 | 62 | 66 | | | TENSILE STRENGTH (Mpa) | Min. 10.0 | Min. 10.00 | Min. 10.00 | Min. 10.00 | JIS-2045.5.2 | | ELONGATION (Min.) | 350% | 350% | 350% | 350% | JIS-2045.5.2 | | WEIGHT (g/pc) | 7.0 | 8.0 | 9.0 | 9.5 | ±0.2g | | THICKNESS | Finger Tip 0.08mm ± 0.02mm Cuff 0.09mm ± 0.02mm Palm 0.15mm ± 0.02mm | | | | | | QUALITY ASSURANCE | UNDER 4% PINHOLE RATE | | | | FDA GLOVE 1000 ML WATER LEAK TEST | 10.0 Conclusion: Shinjiazhuang Hongray Plastic Products Co., Ltd. Vinyl Patient Examination Gloves meet ASTM Standards - meets pinhole requirements and labeling claims.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...