ACTITORIC (OCUFILCON A) SOFT (HYDROPHILIC) TORIC CONTACT LENS FOR DAILY WEAR
Applicant
Hydron , Ltd.
Product Code
LPL · Ophthalmic
Decision Date
Feb 18, 1999
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 886.5925
Device Class
Class 2
Intended Use
The Hydron ActiToric(ocufilcon A) Soft (Hydrophilic) Toric Contact Lors is indicated for daily wear for the correction of reactive ametmpia (myopia, hyperopia and astigmatism) In aphakic and non-aphakicpersons with non-diseased eyes that may exhibit refractive and/or comeal astigmatism up to 2.50 diopters. Eyecare practitioners may prescribe the lens for planned frequent replacement wear, with cleaning, disinfection and replacement. The lens may be disinfected using either a heat, chemical or hydrogen peroxide disinfortion system.
Device Story
ActiToric is a soft, hydrophilic toric contact lens; hemispherical shell design; manufactured via spin-casting using ocufilcon A (HEMA, MA, EGDMA). Prism-ballasted, non-truncated design with inferior slab-off; orientation marks molded into front surface. Axis stabilization achieved via eyelid interaction with differential thickness profile. Prescribed by eyecare practitioners for daily wear; patient performs cleaning, disinfection, and replacement. Corrects myopia, hyperopia, and astigmatism by conforming to corneal surface and providing refractive power. Benefits include improved visual acuity for patients with astigmatism.
Clinical Evidence
No clinical data. Substantial equivalence is based on identical material (ocufilcon A), manufacturing process, and physical/mechanical properties to the predicate device.
Technological Characteristics
Material: ocufilcon A (Group 3 ionic polymer); Monomers: 2-HEMA, MA, EGDMA. Manufacturing: Spin-cast. Dimensions: 14.5mm diameter, 0.15mm center thickness. Properties: 45% water content, 1.43 refractive index. Design: Prism-ballasted, non-truncated toric lens with inferior slab-off. Sterilization: Not specified (standard manufacturing process).
Indications for Use
Indicated for daily wear correction of refractive ametropia (myopia, hyperopia, astigmatism) in aphakic and non-aphakic persons with non-diseased eyes exhibiting refractive/corneal astigmatism up to 2.50 diopters.
Regulatory Classification
Identification
A soft (hydrophilic) contact lens is a device intended to be worn directly against the cornea and adjacent limbal and scleral areas of the eye to correct vision conditions or act as a therapeutic bandage. The device is made of various polymer materials the main polymer molecules of which absorb or attract a certain volume (percentage) of water.
Predicate Devices
Specialty UltraVision Specialty T (ocufilcon A) Toric Soft (Hydrophilic) Contact Lens (K963764)
Related Devices
K963764 — SPECIALTY T TORIC (OCUFILCON A) CONTACT LENS FOR DAILY WEAR · Specialty Ultravision, Inc. · Jan 30, 1997
K041608 — C-VUE 55 TORIC (METHAFILCON A) MULTIFOCAL CONTACT LENS · Unilens Corp., USA · Jul 7, 2004
K080755 — SOFLENS DAILY DISPOSABLE TORIC (HILAFILCON B) VISIBILITY TINTED CONTACT LENS · Bausch & Lomb, Inc. · Jun 10, 2008
K971049 — FREQUENCY 38 (POLYMACON) HYDROPHILIC CONTACT LENS FOR DAILY WEAR (CLEAR AND TINTED) · Aspect Vision Care, Ltd. · May 21, 1997
K052290 — AQUASOFT ALL-DAY & ALL-DAY T (HIOXIFILCON A) DAILY WEAR CONTACT LENS · Clearlab Pte , Ltd. · May 15, 2006
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows a black and white logo for the U.S. Department of Health & Human Services. The logo features a stylized eagle with three stripes extending from its head. The words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" are arranged in a circular pattern around the eagle.
Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
AUG 2 5 2005
Hydron Limited c/o Mr. J.B. Holloway Head of Quality and Regulatory Affairs Hawley Lane Farnborough Hampshire GU14 8EQ United Kingdom
Re: K983160
Trade/Device Name: ActiToric (ocufilcon A) Hydrophilic Toric Contact Lens for Daily Wear Regulation Number: 886.5925 Regulation Name: Lenses, Soft Contact, Daily Wear Regulatory Class: II Product Code: LPL Dated: January 8, 1999 Received: January 11, 1999
Dear Mr. Holloway:
This letter corrects the product code in our substantially equivalent letter of February 18. 1999.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In
{1}------------------------------------------------
Page 2 - Mr. J.B. Holloway
addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to continue marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
David M. Whipple
David M. Whipple Acting Director Division of Ophthalmic, and Ear, Nose and Throat Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
510(k) Number (if known): K 983160
Device Name: Hydron ActiToric(ocufflicon A) Soft (Hydrophlic) Tonc Contact Lens for Daily Wear .
Indications For Use:
The Hydron ActiToric(ocufilcon A) Soft (Hydrophilic) Toric Contact Lors is indicated for daily wear for the correction of reactive ametmpia (myopia, hyperopia and astigmatism) In aphakic and non-aphakicpersons with non-diseased eyes that may exhibit refractive and/or comeal astigmatism up to 2.50 diopters.
Eyecare practitioners may prescribe the lens for planned frequent replacement wear, with cleaning, disinfection and replacement. The lens may be disinfected using either a heat, chemical or hydrogen peroxide disinfortion system.
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED
Concurrence of CDRH, Office of Device Evaluation (ODE)
Kaisa Ulaishr
(Division Sign-Off)
Division of Ophthalmic Devices
510(k) Number K983160
(Optional Format 3-10-98)
Prescription Use-(Per 21 CFR 801.109)
OR
Over-The-Counter Use
(Optional Format 1-2-96)
{3}------------------------------------------------
2/18/99
# 510(k) SUMMARY FOR ACTITORIC SOFT (HYDROPHILIC) TORIC CONTACT LENS
#### K NUMBER: 983160
#### APPLICANT INFORMATION:
| Date Prepared: | January 1999 |
|----------------------|---------------------------------------------------------------------|
| Company Name: | Hydron Limited |
| Company Address: | Hawley Lane<br>Farnborough<br>Hants<br>GU14 8EQ<br>United Kingdom |
| Contact Person: | Julian Holloway<br>Head of Quality Assurance and Regulatory Affairs |
| Phone No:<br>Fax No: | 011 44 1252 554500<br>011 44 1252 544040 |
## DEVICE INFORMATION:
| Regulatory Classification: | Class II – Ophthalmic devices |
|----------------------------|------------------------------------------------------|
| Trade Name: | ActiToric (ocufilcon A) |
| Classification Name: | Soft (Hydrophilic) Toric Contact Lens for Daily Wear |
#### EQUIVALENT DEVICE:
Hydron ActiToric (ocufilcon A) Soft (Hydrophilic) Toric Contact Lens for Daily Wear is equivalent to Specialty UltraVision Specialty T (ocufficon A) Toric Soft (Hydrophilic) Contact Lens for Daily Wear approved by the FDA under 510(k) application K963764, Jan. 1997.
ActiToric (ocufilcon A) Soft (Hydrophilic) Toric Contact Lens for Daily Wear is substantially equivalent to the indication for use of the Specialty T (ocufilcon A) Soft (Hydrophilic) Toric Contact Lens for Daily Wear marketed for use in the US. This lens is in Group 3 ionic, low water content polymers as established by the FDA and located in the Guidance Document for Daily Wear Contact Lenses, Revised Edition May 1994. The physical, and chemical properties of the ActiToric (ocufilcon A) Soft (Hydrophilic) Toric contact Lens for Daily Wear are equivalent to those of the Specialty T (ocufilcon A) Toric Soft (Hydrophilic) Contact Lens for Daily Wear. The subject device utilises the same formulation, manufacturing and sterilisation processes, packaging, Quality Control/Quality Assurance Procedures and established shelf life as the predicate device, the Specialty UltraVision Specialty T (ocufilcon A) Toric Soft (Hydrophilic) Contact Lens for Daily Wear.
A side by side comparison of the physical, optical and mechanical properties establishes the equivalency of these two contact lens products (see Table 2.1).
{4}------------------------------------------------
| Property | ActiToric | Specialty T |
|--------------------------|---------------------------------|---------------------------------|
| Material: | | |
| USAN | ocufilcon A | ocufilcon A |
| Group | 3 (ionic) | 3 (ionic) |
| Monomers | 2-HEMA, MA, EGDMA | 2-HEMA, MA, EGDMA |
| Manufacturing; | | |
| Process | Spun-cast | Spun-cast |
| Diameter (mm) | 14.5 | 14.5 |
| Center Thickness (mm) | 0.15 | 0.15 |
| Base curve (mm) | 8.95 | 8.90 |
| | (equivalent) | (equivalent) |
| Physical Properties: | | |
| Refractive Index | 1.43 ± 0.001 | 1.43 ± 0.001 |
| Water content % | 45 ± 0.00 | 45 ± 0.00 |
| Oxygen Permeability* | $11.9 \pm 1.85 \times 10^{-11}$ | $12.2 \pm 1.41 \times 10^{-11}$ |
| Light Transmittance % | 98 ± 0.4 | 99 ± 0.4 |
| Mechanical Properties: | | |
| Modulus (N/mm²) | 0.32 ± 0.045 | 0.33 ± 0.056 |
| Tensile strength (N/mm²) | 0.32 ± 0.116 | 0.30 ±0.010 |
| Elongation at break (%) | 208 ± 94 | 186 ± 89 |
Table 2.1. Summary of Properties of ActiToric and the Predicate Device, Specialty T.
* measured on single lenses Units: (cm² x ml O₂)/(sec x ml x mmHg)
a production of the contribution of the comments of the comments of the comments of the comments of
the state of the state of the states
{5}------------------------------------------------
### DESCRIPTION OF THE DEVICE:
The ActiToric soft contact lens is a hemispherical shell manufactured of polymerised material of HEMA and other monomeric incredients crosslinked with EGDMA and other components which yield the appearance of a lens which is designed to fit over the corneal surface of the eve. This lens is designed with varying base curves which conform to the shape of the radius of the cornea and centre over the apex of the cornea to provide corrective refraction for functional conditions of the eye including myopia (near-sightedness), hyperopia (farsightedness) and astigmatism (multiple foci). The lens provides corrective power which is to correspond to the refractive power of the eve to which it is being treated. The lens has an aspheric base curve that is formed in the free surface during the spinning process. Secondary and tertiary curves as well as bevelled edge configurations are built into the lens for the purpose of aiding in lens centration and comfort. The lens is manufactured by spin casting and has a front toric surface which is determined by the shape of the mould to provide consistent optics. Onentation marks are moulded into the front surface as part of the spin casting process. The lens is a prism ballasted, non-truncated toric, with an inferior slab off to help maintain patient comfort. Axis stabilisation is action of the action of the lids on the differential thickness profile (prism) of the lens squeezing the thicker portion of the lens to the bottom.
### INDICATIONS FOR USE:
Device Name: Hydron ActiToric (ocufilcon A) Soft (Hydrophilic) Toric Contact Lens for Daily Wear.
The Hydron ActiToric (ocufilcon A) Soft (Hydrophilic) Toric Contact Lens is indicated for daily wear for the correction of refractive ametropia (myopia, hyperopia and astigmatism) in aphakic and not-aphakic persons with non-diseased eyes that may exhibit refractive and/or corneal astigmatism up to 2.50 diopters.
Eyecare practitioners may prescribe the lens for frequent/planned replacement wear, with cleaning, disinfection and replacement. The lens may be disinfected using either a heat, chemical or hydrogen peroxide disinfection system.
### TECHNICAL SUMMARY:
- 1. Toxicology
All necessary toxicology studies were undertaken and results were within normal limits.
- 2. Microbiology
Relevant test procedures have been undertaken and are included with this 510(k) notification.
- 3. Compatibility
Compatibility testing is not required as recommended lens care products have been approved for the same lens material (ocufilcon A).
{6}------------------------------------------------
#### Lens Stability 4.
Lens stability testing indicates that the ActiToric lenses can be stored for a time period of up to 8 years with no adverse effect on the lenses.
#### 5. Clinical
Clinical safety data is not required as the device has the same USAN and method of manufacture as the predicate device.
の 2007年 10月 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 10時 1
.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.