K991038 · Britt Corp., Inc. · JOW · Jun 22, 2000 · Cardiovascular
Device Facts
Record ID
K991038
Device Name
VASO PRESS DVT SYSTEM, MODELS VP500, VP501
Applicant
Britt Corp., Inc.
Product Code
JOW · Cardiovascular
Decision Date
Jun 22, 2000
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.5800
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Vaso Press system is an external pneumatic compression system intended to lower the risk of deep vein thrombosis (DVT) in patients whom may be at risk
Device Story
Vaso Press DVT System (Models VP500 pump, VP501 sleeve) is an external pneumatic compression device. System applies intermittent pneumatic pressure to patient limbs to promote venous blood flow and reduce DVT risk. Used in clinical settings; operated by healthcare professionals. Device consists of a pump unit connected to a compression sleeve. Output is mechanical compression of the limb. Benefits include prophylaxis against DVT in at-risk patients.
Clinical Evidence
No clinical data provided; substantial equivalence determination based on regulatory review.
Technological Characteristics
External pneumatic compression system consisting of a pump (VP500) and sleeve (VP501). Operates via pneumatic pressure. Class II device.
Indications for Use
Indicated for patients at risk of deep vein thrombosis (DVT).
Regulatory Classification
Identification
A compressible limb sleeve is a device that is used to prevent pooling of blood in a limb by inflating periodically a sleeve around the limb.
Related Devices
K061814 — VASOPRESS DVT SYSTEM, MODEL VP500D · Compression Therapy Concepts, Inc. · Nov 30, 2006
K101915 — VASOPRESS SUPREME MINI MODEL VP500DM · Compression Therapy Concepts, Inc. · Aug 6, 2010
K142772 — Phlebo Press DVT 603 · Mego Afek AC , Ltd. · Dec 16, 2014
Submission Summary (Full Text)
{0}------------------------------------------------
### 510(k) Summary of Safety and Effectiveness
### The following section is included as required by the Safe Medical Device Act (SMDA) of 1990.
Name: Britt Corp. Address: 16 Crest Drive, colts Neck, NJ 07722 PO Box 547, Freehold, NJ 07728 Contact Person: J. James Britton Phone Number: (732) 817-1122 Fax Number: (732) 817-1123
## 510(k) Statement of Safety and Effectiveness
This statement regarding 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.93.
I certify that in my capacity as President of Britt Corp., I will make available all information included in this premarket notification on safety and effectiveness within 30 days of request by any person if the device described in the premarket notification is determined to be substantially equivalent. The information I agree to make available will be a duplicate of the premarket notification submission. including any adverse safety and effectiveness information, but excluding all patient identifiers, and trade secret and confidential commercial information, as defined in 21 CFR 20.61.
Signed:
Name:
Name: V. James Britton Position: President Date: March 9, 1999
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a black and white seal for the Department of Health & Human Services - USA. The seal is circular with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. In the center of the seal is an abstract image of an eagle.
# JUN 2 2 2008
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
Mr. J. James Britton President Britt Corp PO Box 547 Freehold, NJ 07728
Re: K991038 Vaso Press DVT System, Models VP500, VP501 Requlatory Class: II (two) Product Code: JOW Dated: March 22, 2000 March 27, 2000 Received:
Dear Mr. Britton:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls The general controls provisions of the Act provisions of the Act. include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such Existing major regulations affecting your device additional controls. can be found in the Code of Federal Regulations, Title 21, Parts 800 to A substantially equivalent determination assumes compliance with 895. the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP requlation may result in requlatory action. In addition, FDA may publish further announcements concerning your device in the Please note: this response to your premarket Federal Register. notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws on requlations.
{2}------------------------------------------------
Page 2 - Mr. J. James Britton
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4648. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".
Sincerely yours,
Brim E. Haimer
James E. Dillard III Director Division of Cardiovascular and Respiratory Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Page 1 of 1
510(k) Number (if known): K991038
Vaso Press DVT System, Pump Model VP 500 and Sleeve Model VP 501 Device Name:
Indications For Use:
The Vaso Press system is an external pneumatic compression system intended to lower the risk of deep vein thrombosis (DVT) in patients whom may be at risk
## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Y Bere A. Kemper le
**(Division Sign-Off)**
(Division Sign-Off) Division of Cardiovascular, Respiratory, and Neurological Devices
**510(k) Number** K991039
(Optional Format 3-10-98)
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.