SOLAR 9000 ANESTHESIA INFORMATION MONITOR

K954852 · Marquette Electronics, Inc. · DSI · May 29, 1996 · Cardiovascular

Device Facts

Record IDK954852
Device NameSOLAR 9000 ANESTHESIA INFORMATION MONITOR
ApplicantMarquette Electronics, Inc.
Product CodeDSI · Cardiovascular
Decision DateMay 29, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1025
Device ClassClass 2
AttributesPediatric

Intended Use

Use of the Marquette Solar 9000 Anesthesia Information Monitor is intended for patient populations including: adult, pediatric, and/or neonatal. Use of the Marquette Solar 9000 Anesthesia Information Monitor is not recommended for use in patient's home or residence, during patient transport, or when it has not been ordered by a physician or other qualified personnel. Use of the Marquette Solar 9000 Anesthesia Information Monitor is intended for operating room (OR), post anesthesia recovery, critical care, surgical intensive care, respiratory intensive care, coronary care, medical intensive care, pediatric intensive care, or neonatal intensive care. These departments are typically located in hospitals or may be located in outpatient clinics or free standing surgical centers. It is intended for use by physicians, physician assistants, registered nurses, certified registered nurse anesthetists, or other hospital personnel trained in the use of the equipment.

Device Story

Solar 9000 Anesthesia Information Monitor is a multi-parameter patient monitoring system. Inputs: physiological data from Tram-Net (Unity) network and Tram acquisition modules. Processes: displays ECG, QRS, arrhythmia, heart rate, ST-segment, cardiac output, wedge pressure, blood pressure, respiratory rate, apnea detection, anesthesia/respiratory gases, pulse oximetry, plethysmography, and temperature. Output: real-time waveforms and numerical data on a color display. Used in hospitals (OR, ICU, recovery) by trained clinicians (physicians, nurses, CRNAs). Clinicians interact via display to select waveforms, review trends, and manage alarms. Facilitates clinical decision-making by providing continuous patient status updates.

Clinical Evidence

No clinical data provided. Substantial equivalence is based on technological characteristics and intended use compared to the predicate device.

Technological Characteristics

Modular patient monitoring system; interfaces with Tram-Net network and Tram acquisition modules. Displays ECG, pressure, and respiratory waveforms. Parameters include gas analysis (CO2, O2, N2O, anesthetic agents), cardiac output, temperature, and pulse oximetry. Connectivity via proprietary network. Software-based processing for arrhythmia detection and parameter computation.

Indications for Use

Indicated for adult, pediatric, and neonatal patient populations requiring physiological monitoring in hospital settings, including OR, ICU, and recovery areas. Not for home use or patient transport.

Regulatory Classification

Identification

The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs.

Special Controls

*Classification.* Class II (special controls). The guidance document entitled “Class II Special Controls Guidance Document: Arrhythmia Detector and Alarm” will serve as the special control. See § 870.1 for the availability of this guidance document.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0} K954852 # 510(k) Summary of Safety and Effectiveness 1. **Manufacturer/ Submitter** Marquette Electronics, Inc. 8200 West Tower Avenue Milwaukee, WI 53223 U.S.A. **Establishment Registration Number:** 2124823 **Contact Name/ Telephone Number:** Dianne Schmitz Corporate Regulatory Affairs Marquette Electronics, Inc. **Phone:** (414) 362-3230 **Date:** October 17, 1995 2. **General Device Information** **Common/ Usual Name** This device is commonly known as a patient monitoring system. **Trade/ Proprietary Name** Marquette Electronics, Inc's trade/ proprietary name for this device is the Solar 9000 Anesthesia Information Monitor. **Classification Name(s)** The Marquette Solar 9000 Anesthesia Information Monitor's classification names, classification panels, and regulation citations include: - *21 CFR 868.1400 Analyzer, Gas, Carbon-Dioxide, Gaseous-Phase* 73CCK - *21 CFR 868.1500 Analyzer, Gas, Enflurane, Gaseous-Phase (Anesthetic Conc.)* 73CBQ - *21 CFR 868.1620 Analyzer, Gas, Halothane, Gaseous-Phase,(Anesthetic Conc.)* 73CBS - *21 CFR 868.1690 Analyzer, Gas, Nitrogen Gaseous-Phase* 73CCI - *21 CFR 868.1700 Analyzer, Gas, Nitrous-Oxide, Gaseous-Phase, (Anesthetic Conc.)* 73CBR - *21 CFR 868.1720 Analyzer, Gas, Oxygen, Gaseous-Phase* 73CCL - *21 CFR 868.2375 Monitor, Breathing Frequency* 73BZQ - *21 CFR 870.1025 Detector and Alarm, Arrhythmia* 74DSI - *21 CFR 870.1100 Monitor, Blood Pressure, Indwelling* 74CAA - *21 CFR 870.1130 Monitor, Blood Pressure, Non-Indwelling* 74BXD 602 {1} * 21 CFR 870.1435 Cardiac Output, Thermal (Balloon Type Catheter) 74KFN * 21 CFR 880.2910 Monitor, Temperature (with probe) 80BWX * 21 CFR 870.2300 Monitor, Cardiac (Incl. cardiotachometer & rate alarm) 74DRT * 21 CFR 870.2700 Oximeter, Pulse 74BWS ## Device Classification Devices monitoring similar parameters, except the "Detector and Alarm, Arrhythmia" parameter, have been determined to be Class II devices according to the Anesthesiology and/ or Cardiovascular Device Classification Panels. The "Detector and Alarm, Arrhythmia" parameter is a Class III parameter. Because the Marquette Solar 9000 Anesthesia Information Monitor may acquire and display data from a module that may include this Class III parameter, it is believed that FDA may classify the system as a Class III device. ## Performance Standards Performance standards (Section 514 of the Act) have not yet been established for the device that is the subject of this premarket notification submission. ## 3. Legally Marketed Predicate Device The Marquette Solar 9000 Anesthesia Information Monitor is substantially equivalent, with similar indications for use to the following devices which are currently legally marketed and in commercial distribution: * K900598 Tramscope System ## 4. Device Description The Marquette Solar 9000 Anesthesia Information Monitor is a patient monitoring system that is designed to display patient physiological data that is received from the Marquette Electronic's Tram-Net (Unity) network, Tram individual and multi-parameter data acquisition modules (K900540), and other compatible modules, as referenced within the Premarket Notification Submission. The data and information these modules acquire includes, but is not limited to: Electrocardiography (ECG) information, QRS and arrhythmia detection, heart rate calculation, ST-segment analysis, cardiac output, wedge determination, and systolic, diastolic, and mean pressure measurements. Additional data and information that these modules acquire includes: respiratory rate detection and computation, detection of a no breath (or apneic) period, respiratory and anesthesia gas parameters, ventilation parameters, pulse oximetry values, plethysmograph values, and temperature measurements. The Solar 9000 Anesthesia Information Monitor is designed to display ECG and pressure and respiratory waveforms generated from the network and the various acquisition modules. The operator uses the system to interact with the acquired data via a color display device. This interaction includes: selecting which waveforms or parameters are displayed, display and review of trended data, silencing alarms, adjusting parameter alarm levels, or printing selected data. 1221 603 {2} # 5. Intended Use Use of the Marquette Solar 9000 Anesthesia Information Monitor is intended for patient populations including: adult, pediatric, and/or neonatal. Use of the Marquette Solar 9000 Anesthesia Information Monitor is not recommended for use in patient's home or residence, during patient transport, or when it has not been ordered by a physician or other qualified personnel. Use of the Marquette Solar 9000 Anesthesia Information Monitor is intended for operating room (OR), post anesthesia recovery, critical care, surgical intensive care, respiratory intensive care, coronary care, medical intensive care, pediatric intensive care, or neonatal intensive care. These departments are typically located in hospitals or may be located in outpatient clinics or free standing surgical centers. It is intended for use by physicians, physician assistants, registered nurses, certified registered nurse anesthetists, or other hospital personnel trained in the use of the equipment. 1222 604
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...