K960250 · Becton Dickinson Vacutainer Systems · JKA · Mar 29, 1996 · Clinical Chemistry
Device Facts
Record ID
K960250
Device Name
VACUTAINER BRAND PLUS SERUM & SST TUBES
Applicant
Becton Dickinson Vacutainer Systems
Product Code
JKA · Clinical Chemistry
Decision Date
Mar 29, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 862.1675
Device Class
Class 2
Intended Use
An evacuated tube which provides a means of collecting, transporting, separating and processing venous blood in a closed system. Blood collected in these tubes is primarily used for clinical laboratory chemistry assays using patient serum but may be used for other serum specimens as determined by the laboratory.
Device Story
Evacuated plastic tubes (Serum and SST Serum Separator) used for venous blood collection; transport; separation; processing. Modification involves reduced silicone surfactant coating in 'full draw' tubes. Used in clinical laboratory settings by phlebotomists or laboratory personnel. Tubes facilitate serum separation via gel barrier; samples processed for chemistry assays (e.g., glucose, cholesterol, electrolytes). Output is serum specimen for diagnostic testing. Benefits include reduced breakage; improved waste disposal; reduced blood exposure via HEMOGARD closure; minimized interference for specific analytes (Vitamin B12, folate) on CIBA Corning ACS:180 Analyzer.
Clinical Evidence
Bench testing and clinical performance studies conducted. Analyte comparison (albumin, ALT, AST, bilirubin, BUN, calcium, chloride, cholesterol, creatinine, glucose, GGT, iron, phosphorus, potassium, sodium, protein, triglycerides, uric acid) showed equivalent performance to current tubes. Interference study demonstrated minimized B12/folate interference on CIBA Corning ACS:180. Visual assessment of gel barrier and hemolysis performed. Partial draw tubes excluded from modification due to observed red blood cell film.
Technological Characteristics
Evacuated plastic tubes with silicone surfactant coating and gel barrier. Includes HEMOGARD closure. Designed for venous blood collection and serum separation.
Indications for Use
Indicated for the collection, transport, separation, and processing of venous blood for clinical laboratory chemistry assays in patients requiring serum analysis.
Regulatory Classification
Identification
A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate serum from nonserum (cellular) components prior to further testing. This generic type device may include blood collection tubes, vials, systems, serum separators, blood collection trays, or vacuum sample tubes.
Predicate Devices
VACUTAINER Brand PLUS Serum and SST Serum Separator Tubes (All Tube Volumes)
K023331 — BD VACUTAINER SST II PLUS TUBES · Becton, Dickinson & CO · Nov 25, 2002
K093910 — IMPROVACUTER GEL & CLOT ACTIVATOR TUBE · Guangzhou Improve Medical Instruments Co., Ltd. · Jul 12, 2010
Submission Summary (Full Text)
{0}
Becton Dickinson VACUTAINER Systems
1 Becton Drive
Franklin Lakes, New Jersey 07417-1885
(201) 847-4500
# BECTON DICKINSON
K90020
## 510(k) SUMMARY
MAR 29 1996
**Submitter:** Denise Duchene
Becton Dickinson VACUTAINER Systems
1 Becton Drive
Franklin Lakes, New Jersey 07417-1885
201-847-6280
**Date:** January 9, 1996
**Device:** VACUTAINER® Brand PLUS (plastic) Serum and SST® Serum Separator Tubes ("Full Draw" Tubes Only)
**Classification:** 75JKA - Tubes, Vials, Systems, Serum Separators, Blood Collection
**Predicate Device:** VACUTAINER® Brand PLUS Serum and SST® Serum Separator Tubes (All Tube Volumes)
**Intended Use:** An evacuated tube which provides a means of collecting, transporting, separating and processing venous blood in a closed system. Blood collected in these tubes is primarily used for clinical laboratory chemistry assays using patient serum but may be used for other serum specimens as determined by the laboratory.
**Proposed Modification:** Reduction in the amount of the silicone tube coating.
Becton Dickinson VACUTAINER Systems has determined that the reduction in the amount of silicone surfactant in the "full draw" tubes will not impact the safety or effectiveness of the product for its intended use. Testing has shown that the clinical performance of the proposed tubes is equivalent to the current plastic tubes.
No new claims will be made for either the VACUTAINER® Brand PLUS Serum or PLUS SST® Serum Separator Tubes.
## Synopsis of Test Methods and Results
- Breakage reduction is demonstrated in a study consisting of drop testing and centrifugation testing.
{1}
- Waste disposal improvement is demonstrated in a study of the by products of incineration for the components separately and the product as a whole.
- Reduced blood exposure is demonstrated in a study comparing VACUTAINER® Brand Tubes with the HEMOGARD™ closure to both VACUTAINER® Brand Tubes with the conventional rubber stopper and competitive tubes.
- Equivalent clinical performance to the current VACUTAINER® Brand Tubes was demonstrated in a study which compared the current VACUTAINER® Brand PLUS SST® Serum Separator Tube to the proposed VACUTAINER® Brand PLUS SST® Serum Separator Tube for the following analytes: albumin, alkaline phosphatase, alanine aminotransferase (ALT), aspartate aminotransferase (AST), bilirubin (initial time only), blood urea nitrogen (BUN), calcium, chloride, cholesterol, creatinine, glucose, gamma-glutamyl transferase (GGT), iron, phosphorus, potassium, sodium, protein, triglycerides, and uric acid. A difference in lactate dehydrogenase (LD) levels was noted. The performance characteristics of the gel barrier and the presence of fibrin, red cells and hemolysis were assessed visually. The partial draw evaluation tubes exhibited a film of red blood cells on the tube wall above the barrier; therefore, these tubes will not be modified. Note: All 13 X 100 size tubes used in clinical studies were partial draw tubes.
The results demonstrated equivalent functional performance.
- Minimization of the possibility of obtaining elevated levels of vitamin B₁₂ and folate obtained when these Tubes are used to collect samples to be tested on the CIBA Corning ACS:180® Analyzer was demonstrated in a study comparing the current glass VACUTAINER® Brand Serum Tube without silicone to the proposed VACUTAINER® Brand SST® Serum Separator Tube. The glass VACUTAINER® Brand Serum Tube was chosen as the control because this tube has no coatings. The study was performed in collaboration with CIBA Corning Diagnostics. NOTE: This report is proprietary and confidential and is the property of CIBA Corning Diagnostics and Becton Dickinson VACUTAINER Systems.
The results demonstrated a minimization of the interference.
47
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.