BD MICROTAINER MAP MICROTUBE FOR AUTOMATED PROCESS, MODEL 363706

K093972 · Becton, Dickinson & CO · JKA · Jan 21, 2010 · Clinical Chemistry

Device Facts

Record IDK093972
Device NameBD MICROTAINER MAP MICROTUBE FOR AUTOMATED PROCESS, MODEL 363706
ApplicantBecton, Dickinson & CO
Product CodeJKA · Clinical Chemistry
Decision DateJan 21, 2010
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 862.1675
Device ClassClass 2

Intended Use

The BD Microtainer® K₂EDTA tube with Microgard Closure and Extender is intended for the collection, transport, and processing of capillary blood specimens.

Device Story

BD Microtainer® MAP Microtube is a blood collection device for skin puncture specimens. It features a one-piece plastic reservoir and integrated extender, providing external dimensions of a standard 13x75mm tube for compatibility with high-throughput hematology instrument racks. The interior is spray-coated with K2EDTA. The lavender cap includes a penetrable septum, allowing automated instruments to sample blood directly without removing the cap or transferring the specimen. Used in clinical settings by healthcare professionals; the device streamlines workflow by eliminating manual sample transfer steps. Benefits include reduced risk of sample exposure and improved compatibility with automated laboratory processing.

Clinical Evidence

Mechanical, simulated use, and clinical testing were performed to demonstrate safety and effectiveness. No specific clinical trial metrics (e.g., sensitivity, specificity) were provided in the summary document.

Technological Characteristics

Plastic reservoir with integrated extender (13x75mm dimensions); K2EDTA additive; penetrable septum cap. Compatible with high-throughput hematology instruments. Manual and automated processing modes.

Indications for Use

Indicated for collection, transport, and processing of capillary blood specimens in patients requiring blood analysis.

Regulatory Classification

Identification

A blood specimen collection device is a device intended for medical purposes to collect and to handle blood specimens and to separate serum from nonserum (cellular) components prior to further testing. This generic type device may include blood collection tubes, vials, systems, serum separators, blood collection trays, or vacuum sample tubes.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K093972 ## 510(k) Summary Of Safety and Effectiveness JAN 2 1 2010 - l. General Information This Summary of Safety and Effectiveness information is being submitted in accordance with the requirements of the SMDA of 1990 and 21 § 807.92. ## Establishment: r P | • | Address: | Becton, Dickinson and Company<br>BD Diagnostics, Preanalytical Systems<br>1 Becton Drive<br>Franklin Lakes, NJ 07417-1885 | |--------|------------------------|---------------------------------------------------------------------------------------------------------------------------| | • | Registration Number: | 2243072 | | • | Contact Person: | Julie Tom Wing<br>Regulatory Affairs Specialist<br>Telephone no.: 201-847-4260<br>Fax No. 201-847-4858 | | • | Date of Summary: | December 23, 2009 | | Device | | | | • | Trade Name: | BD Microtainer® MAP Microtube for Automated<br>Process | | • | Classification Name: | Tubes, Vials, Systems, Serum Separators,<br>Blood Collection | | • | Classification: | Class II | | • | Performance Standards: | None Established under 514 of the Food, Drug<br>and Cosmetic Act | Special 510 (k): Premarket Notification BD Microtainer® MAP Microtube for Automated Process {1}------------------------------------------------ II. Safety and Effectiveness Information Supporting Substantial Equivalence - · Device Description ੇ BD Microtainer® MAP Microtube for Automated Process consists of a plastic reservoir and a lavender cap indicating the presence of K2EDTA. The interior surface of the reservoir is spray-coated with K-EDTA solution, which is then dried. The upper edge of the reservoir serves as a collector for blood specimen. The plastic reservoir is a one piece design - reservoir and extender, which were previously two separate components in the predicate device (K940905). The integrated extender gives the tube an external dimension of a standard tube (13x75mm), while maintaining the same internal characteristics for low specimen volume range and K2EDTA blood to additive ratio as the predicate. The lavender cap features a penetrable septum. These integrated features; one piece reservoir/extender and penetrable cap adapts the tube for compatibility with high throughput hematology instruments. Once the blood specimen is collected and mixed adequately, there is no longer a need to remove the cap, transfer the sample to a suitable container or add an additional component to fit tube racks. BD MAP can be directly processed on high throughput hematology instruments. Markings on the reservoir indicate a blood specimen fill range of 250uL. There is also a tube marking for specimen fill (375uL) when the tube is processed in automated mode. While BD MAP is adaptable to automated processing: the tube remains compatible with automated instruments when processed in the manual mode. - · Intended Use BD Microtainer® MAP Microtube for Automated Process with K2 EDTA is used to collect, anticoagulate, transport and store skin puncture blood specimens for measurement of the following hematology parameters: White Blood Cells (WBC), Red Blood Cells (RBC), Hemoglobin (HgB), Hematocrit (HCT), Mean corpuscular volume (MCV), Mean corpuscular hemoglobin (MCH), Mean corpuscular hemoglobin concentration (MCHC), Platelets, 5-part White Blood Cell (WBC) differentials (Neutrophils, Lymphocytes, Monocytes, Eosinophils, Basophils), Reticulocytes and Whole Blood Lead testing. {2}------------------------------------------------ - · Synopsis of Performance Study Results Mechanical, simulated use and clinical testing were performed to demonstrate the device's safety and effectiveness. III. Predicate Device Summary Table - · Substantial Equivalence . . " Based on comparison of the device features, materials, intended use and performance, BD Microtainer® MAP Microtube for Automated Process with K2EDTA is shown to be substantially equivalent to the commercially available predicate device indicated in the table below. The predicate device, K number, and clearance date are also identified in the table below. | Manufacturer | Predicate Device | K-Number | Clearance Date | |-------------------------------------|--------------------------------------------------------------------------------|----------|-----------------| | Becton,<br>Dickinson and<br>Company | BD Microtainer®<br>K2EDTA tube with<br>Microgard TM<br>Closure and<br>Extender | K940905 | August 02, 1994 | Julie Tom Wing 12/23/2009 **Date** Julie Pom Wing Regulatory Affairs Specialist Becton, Dickinson and Company BD Diagnostics, Preanalytical Systems {3}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" arranged around the perimeter. Inside the circle is an abstract symbol that resembles a stylized caduceus or a representation of human figures. ## DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Mail Center-WO66-G609 Silver Spring, MD 20993-0002 JAN 2 1 2010 Becton, Dickinson & Co. BD Diagnostics, Preanalytical c/o Ms. Julie T. Wing Regulatory Affairs Specialist 1 Becton Drive, MC 300 Franklin Lakes, NJ 07417-1880 Re: k093972 Trade/Device Name: BD Microtainer® MAP Microtube for Automated Process Regulation Number: 21 CFR 862.1675 Regulation Name: Blood specimen collection device Regulatory Class: Class II Product Code: JKA Dated: January 15, 2010 Received: January 19, 2010 Dear Ms. Wing: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the iddinous for use stated in the enclosure) to legally marketed predicate devices marketed in internate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Or to and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, isting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into class II (Special Controls), it may be subject to such. additional controls. Existing major regulations affecting your device can be found in Title 2 to Code of Federal Regulations (CFR), Parts 800 to 895. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 {4}------------------------------------------------ Page 2 - Ms. Julie T. Wing CFR Part 807): labeling (21 CFR Parts 801 and 809); medical device reporting of medical device-related adverse events) (21 CFR 803); and good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820). This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Office of In Vitro Diagnostic Device Evaluation and Safety at (301) 796-5450. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours. m chan Maria M. Chan, Ph.D. Director Division of Immunology and Hematology Devices Office of In Vitro Diagnostic Device Evaluation and Safety Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ## Indications for Use 510(k) Number (if known): K093972 Device Name: BD Microtainer® MAP Microtube for Automated Process Indications For Use: BD Microtainer® MAP Microtube for Automated Process with K2EDTA is used to collect, anticoagulate, transport and store skin puncture blood specimens for measurement of the following hematological parameters: White Blood Cells (WBC), Red Blood Cells (RBC), Hernoglobin (HgB), Hematocrit (HCT), Mean corpuscular volume (MCV), Mean corpuscular hemoglobin (MCH), Mean corpuscular hemoglobin concentration (MCHC), White Blood Cell (WBC) differentials (Neutrophils, Platelets, 5-part Lymphocytes, Monocytes, Eosinophils, Basophils), Reticulocytes and Whole Blood Lead testing. Prescription Use × (Part 21 CFR 801 Subpart.D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of In Vitro Diagnostic Devices (OIVD) **Division Sign-Off** Office of in Vitro Diagnostic Device Evaluation and Safety. 510(k) K093972
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...