PML · Bone Cement, Posterior Screw Augmentation

Orthopedic · 21 CFR 888.3027 · Class 2

Overview

Product CodePML
Device NameBone Cement, Posterior Screw Augmentation
Regulation21 CFR 888.3027
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

Polymethylmethacrylate (PMMA) bone cement is a device intended to be implanted that is made from methylmethacrylate, polymethylmethacrylate, esters of methacrylic acid, or copolymers containing polymethylmethacrylate and polystyrene. The device is intended for use in arthroplastic procedures of the hip, knee, and other joints for the fixation of polymer or metallic prosthetic implants to living bone.

Classification Rationale

Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Polymethylmethacrylate (PMMA) Bone Cement.”

Special Controls

*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Polymethylmethacrylate (PMMA) Bone Cement.”

Recent Cleared Devices (19 of 19)

RecordDevice NameApplicantDecision DateDecision
K260286Dynamo™ Spinal Cement; Salvo® Spine SystemSpine Wave, Inc.Jun 15, 2026SESE
K252885OLYMPIC Posterior Spinal Fixation System; MASADA Modular Spinal Fixation SystemAstura MedicalJan 22, 2026SESE
K241034Meta+ Bone Cement & M.U.S.T. Fenestrated Pedicle Screw SystemMedacta International S.A.Jun 12, 2024SESE
K231809Momentum® Posterior Spinal Fixation System with G21 V-STEADY Bone Cement; Momentum® MIS Posterior Spinal Fixation System with G21 V-STEADY Bone CementUlrich Medical USAOct 20, 2023SESE
K230774PERLA® TL System; TEKTONA® HV US Bone CementSpineartJun 23, 2023SESE
K222789VADER® Pedicle System, G21 CementIcotec AGJan 9, 2023SESE
K221926Invictus® Bone Cement, Invictus Spinal Fixation SystemAlphatec Spine, Inc.Dec 20, 2022SESE
K222256BonOs® Inject Bone Cement; NEO Pedicle Screw System™Neo Medical SAAug 26, 2022SESE
K212489BonOs Inject Bone Cement; NEO Pedicle Screw SystemNeo Medical SAOct 28, 2021SESE
K200596G21 Cement, VADER® Pedicle SystemIcotec AGOct 13, 2020SESE
K201362CD Horizon™ Fenestrated Screw Set, CD Horizon™ Spinal System, Kyphon™ HV-R™ Bone CementMedtronicAug 19, 2020SESE
K192818Vertaplex HV High Viscosity Radiopaque Bone Cement; ES2 Augmentable Spinal SystemStryker CorporationMar 31, 2020SESE
K190526High V+ Bone Cement, CarboClear® Fenestrated Pedicle ScrewsCarboFix Orthopedics , Ltd.Sep 19, 2019SESE
K191148Medtronic HV-R™ Bone Cement, Kyphon™ Xpede™ Bone Cement, CD Horizon™ Fenestrated Screw SetMedtronic Sofamor Danek USA, Inc.Sep 12, 2019SESE
K180498NuVasive Reline Fenestrated Screws, High V+ Bone CementNu Vasive, IncorporatedNov 28, 2018SESE
K172269FORTRESS™ Radiopaque Bone Cement (FORTRESS™ and FORTRESS-Plus™), CREO® Fenestrated Screw System, REVLOK® Fenestrated Screw SystemGlobus Medical, Inc.Mar 27, 2018SESE
K171938KYPHON Xpede Bone Cement, CD HORIZON Fenestrated Screw SetMedtronicOct 23, 2017SESE
K160879CONFIDENCE™ High Viscosity Spinal Cement, VIPER® and EXPEDIUM® Fenestrated Screw SystemsMedos International SàrlDec 20, 2016SESE
K152604KYPHON HV-R Fenestrated Screw Cement, CD HORIZON Fenestrated Screw SetMedtronic Sofamor Danek USA, IncorporatedJan 6, 2016SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...