K130428 · Biomup S.A. · FTL · Oct 25, 2013 · General, Plastic Surgery
Device Facts
Record ID
K130428
Device Name
COVAMESH
Applicant
Biomup S.A.
Product Code
FTL · General, Plastic Surgery
Decision Date
Oct 25, 2013
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.3300
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
COVAMESH™ is intended for the reinforcement of tissues during surgical repair. It is indicated for the treatment of incisional hernias, abdominal wall repair, and parietal (i.e. pertaining to the walls) reinforcement of tissues. The non-resorbable three dimensional polyester mesh provides long-term reinforcement of soft tissues.
Device Story
COVAMESH™ is a surgical mesh for open (laparotomy) or laparoscopic soft tissue reinforcement. Device consists of 3D polyethylene terephthalate (polyester) mesh coated with a cross-linked, resorbable porcine-derived collagen film. Collagen film acts as a hydrophilic barrier to separate mesh from viscera/organs. Device is rollable for trocar introduction, suturable, and features non-resorbable ink markings for positioning. Used by surgeons in clinical settings. Provides long-term soft tissue reinforcement via the polyester component while minimizing tissue attachment via the collagen barrier. Sterilized via gamma-irradiation.
Clinical Evidence
No human clinical data. Evidence consists of bench testing (thickness, pore size, density, tensile strength, suture pullout, tear resistance) and in vivo animal model performance testing comparing tissue response and integration against PARIETEX® COMPOSITE Mesh. Biocompatibility testing performed per ISO 10993-1 and FDA G95-1.
Technological Characteristics
Materials: Polyethylene terephthalate (polyester) and porcine-derived Type I collagen. Structure: 3D knitted mesh with hydrophilic film. Form factor: Round (12-16 cm) or rectangular (up to 36x30 cm) sheets. Sterilization: Gamma-irradiation. Single-use. Non-pyrogenic.
Indications for Use
Indicated for patients requiring surgical repair of incisional hernias, abdominal wall repair, and parietal tissue reinforcement. No specific age or gender contraindications provided.
Regulatory Classification
Identification
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.
{1}------------------------------------------------
K130428 Page 1/4
Image /page/0/Picture/1 description: The image shows the logo for Biom'up Advanced Biomaterials. The logo features the company name in a stylized font, with the "m" and "u" connected. Above the name is a graphic of a series of dots that form a wave-like pattern. Below the name, the words "ADVANCED BIOMATERIALS" are written in a smaller, sans-serif font.
### 510(k) Summary, COVAMESHTM
Submitter's name and address:
Biom'Up S.A. 8, Allee Irene Joliot-Curie 69800. Saint-Priest, France
Contact person:
Valerie Centis, R&D Project Manager and Regulatory Affairs
Biom`Up S.A.S 8, Allee Irene Joliot Curie 69800, Saint-Priest, France Phone: +33 (0)4 86 57 36 10 Fax: +33 (0)4 37 69 00 84 Email: regulatoryaffairs@biomup.com
Date Summary was prepared:
Trade/Proprietary Name: Common/Usual Name: Classification : Product Code: Regulation Number: Device Classification:
Predicate Devices
Mesh, Surgical FTL
21 CFR 878.3300 Class II
October 24, 2013
COVAMESH™
Surgical Mesh
PARIETEX® COMPOSITE Mesh (K040998) Cova™ORTHO NERVE (K103081)
..............................................................................................................................................................................
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
- - -
#### Device Description
- - - - - - -
COVAMESH™ is a surgical mesh used during open procedures (laparotomy) or during laparoscopic procedures. COVAMESHIM is made from polyethylene terephtalate (polyester) and a cross-linked resorbable collagen film of porcine origin. The hydrophilic collagen film physically separates the coated side of the mesh from adjacent tissue, viscera, and organs. A marking with a non-resorbable ink is at the centre of the mesh to help positioning the device. The surgical mesh is obtained by standardized, controlled manufacturing processes. COVAMESHI™ is further sterilized in double-blisters by gamma-imadiation.
. ········
..
COVAMESH™ is designed to be non inflammatory and biocompatible to allow reinforcement of soft tissues. When wetted, the surgical mesh is rollable to be easily introduced in a trocar. COVAMESH™ is suturable in place. It is provided in round sheets of 12 cm diameter and 16cm diameter and in rectangular sheets of 15x10 cm, 20x15 cm, 25x20 cm, 30x20 cm, 36x30 cm.
- Page 1 / 4
・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・
OCT 2 5 2013
{2}------------------------------------------------
Image /page/1/Picture/1 description: The image shows the logo for Biom'up Advanced Biomaterials. The logo features the company name "biom'up" in a bold, sans-serif font, with the "up" portion slightly elevated. Above the name is a graphic of several horizontal lines that curve upwards, resembling a wave or airflow. Below the name, in smaller letters, is the text "ADVANCED BIOMATERIALS".
#### Intended Use
COVAMESH™ is intended for the reinforcement of tissues during surgical repair. It is indicated for the treatment of incisional hernias, abdominal wall repair, and parietal (i.e. pertaining to the walls) reinforcement of tissues. The non-resorbable three dimensional polyester mesh provides long-term reinforcement of soft tissues.
#### Technological Characteristics and Substantial Equivalence
The intended use, product design, physical structure and target population of COVAMESH™ is substantially equivalent to the FDA cleared and legally marketed predicate device PARIETEX® COMPOSITE Mesh (K040998). COVAMESH™ is constructed of a three-dimensional polyester mesh, knitted into a structure similar to PARIETEX® COMPOSITE Mesh (K040998). The collagen component is derived from a porcine source already cleared by FDA for predicate Cova™ORTHO-NERVE (K103081). In addition, COVAMESH™ and predicate devices are available in various sizes and shapes to accommodate different surgical procedures and/or surgeon's choice. Similarities are presented in the following Table.
Any differences in technological characteristics between the COVAMESH™ and the predicate devices do not raise any new issues of safety or efficacy. The performance and safety of the material used was evaluated. The collective results have demonstrated that the COVAMESH™ is substantially equivalent to the respective predicate devices with regard to safety and efficacy.
{3}------------------------------------------------
Image /page/2/Picture/1 description: The image shows the logo for "biom'up ADVANCED BIOMATERIALS". The word "biom'up" is in bold, black font, with the "up" portion slightly elevated. Above the word "biom'up" is a series of short, vertical lines that form a wave-like shape. Below the word "biom'up" is the phrase "ADVANCED BIOMATERIALS" in a smaller, sans-serif font.
| Name | COVAMESH™ | PARIETEX® COMPOSITE Mesh<br>(K040998) | Cova™ ORTHO-NERVE<br>(K103081) |
|-----------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Composition<br>Origin | Type I collagen, polyester<br>Porcine collagen | Type I collagen, polyester<br>Porcine collagen | Type I collagen<br>Porcine collagen |
| Intended use | Indicated for the reinforcement of tissues during surgical repair. It is indicated for the treatment of incisional hernias, abdominal wall repair, and parietal (i.e. pertaining to the walls) reinforcement of tissues. The non-resorbable three dimensional polyester mesh provides long-term reinforcement of soft tissues. | Indicated for the reinforcement of tissues during surgical repair. It is indicated for the treatment of incisional hernias, abdominal wall repair, and parietal (i.e. pertaining to the walls) reinforcement of tissues. The non-resorbable three dimensional polyester mesh provides long-term reinforcement of soft tissues. On the opposite side, the resorbable hydrophilic film minimizes tissue attachment to the mesh in case of direct contact with the viscera. | Indicated for the management of peripheral nerve injuries in which there has been no substantial loss of nerve tissue and where gap closure can be achieved by flexion of the extremity. |
| Characteristics | Hydrophilic film on a 3D polyester mesh<br>Easy to manipulate<br>Smooth (hydrophilic film)<br>Flexible<br>Wettable<br>Rollable | Hydrophilic film on a 3D polyester mesh<br>Easy to manipulate<br>Smooth (hydrophilic film)<br>Flexible<br>Wettable<br>Rollable | Hydrophilic film<br>Easy to manipulate<br>Smooth (hydrophilic film)<br>Flexible<br>Wettable<br>Rollable |
| Biocompatibility | Established | Established | Established |
| Non-pyrogenic | Yes | Yes | Yes |
| Resorbable | Yes (collagen film) | Yes (collagen film) | Yes (collagen film) |
| Suturable | Yes | Yes | Yes |
| Reusable | Single use | Single use | Single use |
| Shelf-life | 6 months | 36 months | 24 months |
| Packaging | Double-peel packages | Double-peel packages | Double-peel packages |
## Table I - COVAMESH™ and its predicates summarized comparison chart.
### Safety Evaluation
Biocompatibility testing was performed according to the FDA Blue Book Memorandum G95-1 and ISO 10993-1. COVAMESHTM passed all of the following tests:
- Cytotoxicity, ・
- . Sensitization,
- -Irritation,
- -Systemic Toxicity (Acute),
- -Genotoxicity- Ames Mutagenesis,
- Genotoxicity Bone Marrow Micronucleus, -
- -Genotoxicity - Mouse Lymphoma Mutagenesis,
- Implantation, •
- Pyrogenicity, t
- Sub-Chronic/Chronic Toxicity. -
{4}------------------------------------------------
Image /page/3/Picture/1 description: The image shows the logo for "biom'up ADVANCED BIOMATERIALS". The word "biom'up" is in bold, black font, with the apostrophe in "biom'up" being red. Above the word "biom'up" is a black, dotted line that is curved. Below the word "biom'up" is the phrase "ADVANCED BIOMATERIALS" in a smaller, black font.
The COVAMESH™ manufacturing process complies with the United States Food and Drug Administration and European Standards for animal tissue sourcing and viral inactivation.
#### Summary of Effectiveness Data
#### Bench testing
Bench testing was conducted in accordance with FDA guidance - Preparation of a Premarket Notification Application Surgical Mesh to evaluate the performance characteristics of COVAMESH™. The thickness, pore size, density, tensile strength, suture pullout strength and tear resistance were all evaluated. The test results showed that COVAMESH™ has similar performance characteristics as previously cleared surgical mesh. Any differences in technological characteristics between the COVAMESH™ and the predicate devices do not raise any new issues of safety or efficacy.
#### Animal Data
In vivo performances testing on two representative animal models were conducted in comparison with the predicate PARIETEX® COMPOSITE Mesh (K040998). The results demonstrate that COVAMESH™ elicits a similar tissue response and has similar tissue integration as compared to the PARIETEX® COMPOSITE Mesh predicate device.
#### Conclusion
COVAMESH™ is substantially equivalent to its predicate devices: PARIETEX® COMPOSITE Mesh (K040998) and Cova™ ORTHO-NERVE (K103081).
{5}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with its wings spread, and three horizontal lines below the eagle. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle.
# DEPARTMENT OF HEALTH & HUMAN SERVICES
Public Realth Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
October 25, 2013
Biom'Up S.A. Ms. Valeria Centis R&D Project Manager and Regulatory Affairs 8, Allee Joliot-Curie 69800 Saint Priest FRANCE
Re: K130428
Trade/Device Name: COVAMESHTM Regulation Number: 21 CFR 878.3300 Regulation Name: Surgical mesh Regulatory Class: Class II Product Code: FTL Dated: September 18, 2013 Received: September 23, 2013
Dear Ms. Centis:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28. 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Ilsting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRFI does not evaluate information related to contract liability warranties. We remind you: however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into cither class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements. including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); medical device reporting (reporting of medical
{6}------------------------------------------------
Page 2 - Ms. Valeria Centis
device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820): and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803). please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biomctrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours,
# Mark N. Melkerson -S
Mark N. Melkerson Acting Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{7}------------------------------------------------
DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
# Indications for Use
Form Approved: OMB No. 0910-0120 Expiration Date: December 31, 2013 See PRA Statement on last page.
510(k) Number (if known) K130428
Device Name COVAMESH™
Indications for Use (Describe)
Intended for the reinforcement of tissues during surgical repair. It is indicated for the treatment of incisional hemias, abdominal wall repair, and parietal (i.e. pertaining to the walls) reinforcement of tissues. The non-resorbable three dimensional polyester mesh provides long-term reinforcement of soft tissues.
Type of Use (Select one or both, as applicable)
> Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
Please do not write below this line - continue on a separate page if needed.
#### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
FORM FDA 3881 (9/13)
PSC Publishing Scrivities (301) 443-4740 EL
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.