PROLENE Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh, PROLENE (Polypropylene) Hernia System, Non-absorbable Synthetic Surgical Mesh

K180829 · ETHICON, Inc. · FTL · Jun 28, 2018 · General, Plastic Surgery

Device Facts

Record IDK180829
Device NamePROLENE Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh, PROLENE (Polypropylene) Hernia System, Non-absorbable Synthetic Surgical Mesh
ApplicantETHICON, Inc.
Product CodeFTL · General, Plastic Surgery
Decision DateJun 28, 2018
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.3300
Device ClassClass 2
AttributesTherapeutic

Intended Use

PROLENE™ Mesh is indicated for the repair of abdominal wall hernias and abdominal wall deficiencies that require the addition of a reinforcing material to obtain the desired surgical result. The PROLENE™ Hernia System is indicated for the repair of abdominal wall hernia defects, including inguinal (direct & indirect).

Device Story

PROLENE Mesh and PROLENE Hernia System are sterile, nonabsorbable synthetic surgical meshes; constructed of knitted filaments of extruded polypropylene; designed for reinforcement of abdominal wall hernias and deficiencies. PROLENE Mesh is a flat sheet; PROLENE Hernia System is a pre-shaped 3D device consisting of an onlay patch connected by a mesh cylinder to an underlay patch. Devices are implanted by surgeons during hernia repair procedures. Mesh provides structural reinforcement to abdominal wall tissue; promotes tissue ingrowth; retains strength indefinitely. No changes to manufacturing, materials, or sterilization from predicate devices; submission addresses labeling updates including new contraindications and formatting for clarity.

Clinical Evidence

No clinical data. Substantial equivalence is based on technological characteristics, design, and material composition identical to predicate devices.

Technological Characteristics

Materials: Knitted filaments of extruded polypropylene (identical to PROLENE suture). Design: PROLENE Mesh is a flat, bi-directional elastic sheet; PROLENE Hernia System is a 3D pre-shaped device (onlay/cylinder/underlay). Sterilization: Unchanged from predicate. Connectivity: N/A (implantable).

Indications for Use

Indicated for repair of abdominal wall hernias and deficiencies requiring reinforcing material; PROLENE Hernia System indicated for abdominal wall hernia defects including inguinal (direct & indirect).

Regulatory Classification

Identification

Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue. June 28, 2018 Ethicon, Inc % Ms. Stephanie Saati Senior Regulatory Affairs Program Lead Route 22 West, P.O. Box 151 Somerville, New Jersey 08876 ## Re: K180829 Trade/Device Name: PROLENE™ Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh, PROLENE™ (Polypropylene) Hernia System, Non-absorbable Synthetic Surgical Mesh Regulation Number: 21 CFR 878.3300 Regulation Name: Surgical Mesh Regulatory Class: Class II Product Code: FTL Dated: March 29, 2018 Received: March 30, 2018 Dear Ms. Saati: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); {1}------------------------------------------------ and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely. # David Krause -S for Binita S. Ashar, M.D., M.B.A., F.A.C.S. Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K180829 Device Name PROLENE™ Mesh Polypropylene Non-Absorbable Synthetic Surgical Mesh PROLENE™ (Polypropylene) Hernia System, Nonabsorbable Synthetic Surgical Mesh #### Indications for Use (Describe) PROLENE™ Mesh is indicated for the repair of abdominal wall hernias and abdominal wall deficiencies that require the addition of a reinforcing material to obtain the desired surgical result. The PROLENE™ Hernia System is indicated for the repair of abdominal wall hernia defects, including inguinal (direct & indirect). Type of Use (Select one or both, as applicable): | <div> <span style="font-size: 10pt;"> <span style="font-family: Wingdings;">X</span> </span> Prescription Use (Part 21 CFR 801 Subpart D) </div> | <div> <span style="font-size: 10pt;"> <span style="font-family: Wingdings;">☐</span> </span> Over-The-Counter Use (21 CFR 801 Subpart C) </div> | |---------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| |---------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------| #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the logo for ETHICON, a Johnson & Johnson company. The word "ETHICON" is written in large, red, sans-serif letters. Below the company name, the text "a Johnson & Johnson company" is written in a smaller, cursive font. The logo is simple and clean, with a focus on the company name. # 510(k) Summary | Submitter: | Ethicon, Inc. a Johnson & Johnson company<br>P.O. Box 151<br>Route 22 West<br>Somerville, NJ 08876-0151 | |---------------------|------------------------------------------------------------------------------------------------------------------------------------| | Contact Person: | Stephanie Saati<br>Senior Regulatory Affairs Program Lead<br>Phone: 908-218-3318<br>Fax: 908-218-2595<br>Email: SSaati@its.jnj.com | | Date Prepared: | March 28, 2018 | | Device Trade Name: | PROLENE™ Polypropylene Mesh Non-Absorbable<br>Synthetic Surgical Mesh | | | PROLENE™ (Polypropylene) Hernia System,<br>Nonabsorbable Synthetic Surgical Mesh | | Device Common Name: | PROLENE™ Mesh | | | PROLENE™ Hernia System | | Class: | Class II | | Classification: | 21 CFR 878.3300 – Surgical Mesh | | Product Code: | FTL | {4}------------------------------------------------ # Predicate Devices: # PROLENE™ Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh | Device | Company | Product Code | 510(k) Number | Predicate for | |----------------------------------------------------------------------------------|------------------|--------------|---------------|------------------------------------------------------------------------------------------------------------------------------| | PROLENE™<br>Polypropylene<br>Mesh<br>Nonabsorbable<br>Synthetic<br>Surgical Mesh | Ethicon,<br>Inc. | FTL | K962530 | Fundamental Scientific<br>Technology, Design,<br>Intended Use, Materials,<br>Construction,<br>Performance<br>Characteristics | # PROLENE™ (Polypropylene) Hernia System, Nonabsorbable Synthetic Surgical Mesh | Device | Company | Product Code | 510(k) Number | Predicate for | |------------------------------------------------------------------------------------------------------------------|------------------|--------------|---------------|------------------------------------------------------------------------------------------------------------------------------| | Modification of<br>PROLENETM<br>(Polypropylene)<br>Hernia System,<br>Nonabsorbable<br>Synthetic<br>Surgical Mesh | Ethicon,<br>Inc. | FTL | K984220 | Fundamental Scientific<br>Technology, Design,<br>Intended Use, Materials,<br>Construction,<br>Performance<br>Characteristics | # Device Description: PROLENE™ Mesh is a sterile, nonabsorbable synthetic surgical mesh designed for the repair of abdominal wall hernias and abdominal wall deficiencies. The implant device is constructed of knitted filaments of extruded polypropylene identical in composition to that used in PROLENE™ Polypropylene Suture, nonabsorbable surgical sutures U.S.P. (Ethicon, LLC). This material, when used as a suture, has been reported to be non-reactive and to retain its strength indefinitely in clinical use. PROLENE™ Mesh is knitted by a process which interlinks each fiber junction and which provides for elasticity in both directions. This construction permits the mesh {5}------------------------------------------------ to be cut into any desired shape or size without unraveling. The fiber junctions are not subject to the same work fatigue exhibited by more rigid metallic meshes. This bi-directional, elastic property allows adaptation to various stresses encountered in the body. PROLENE™ Hernia System is a sterile, pre-shaped, three-dimensional device designed for the repair of abdominal wall hernia defects, including inguinal (direct & indirect). It is constructed of an onlay patch connected by a mesh cylinder to a circular or oblong underlay patch. The material is undyed PROLENE™ (Polypropylene) Mesh constructed of knitted nonabsorbable polypropylene filaments. ## Indications for Use: PROLENE™ Mesh is indicated for the repair of abdominal wall hernias and abdominal wall deficiencies that require the addition of a reinforcing material to obtain the desired surgical result. The PROLENE™ Hernia System is indicated for the repair of abdominal wall hernia defects, including inguinal (direct & indirect). ## Summary of Technological Characteristics: PROLENETM Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh is substantially equivalent to the PROLENE™ Polypropylene Mesh Nonabsorbable Synthetic Surgical Mesh (K962530) predicate device with respect to technological characteristics. Both the subject and predicate devices are constructed of knitted filaments of extruded polypropylene. The devices function in the same manner and are designed to provide reinforcement to repair abdominal wall hernias and abdominal wall deficiencies. The subject mesh is manufactured within the existing manufacturing processes for the predicate device. There are no changes to the manufacturing, packaging, sterilization processes, or shelf life of the currently marketed device. PROLENE™ (Polypropylene) Hernia System. Nonabsorbable Synthetic Surgical Mesh is substantially equivalent to the PROLENE™ (Polypropylene) Hernia {6}------------------------------------------------ System, Nonabsorbable Synthetic Surgical Mesh (K984220) predicate device with respect to technological characteristics. Both the subject and predicate devices are sterile, pre-shaped, three-dimensional devices constructed of an onlay patch connected by a mesh cylinder to a circular or oblong underlay patch. The material used in both devices is undyed PROLENE™ (Polypropylene) mesh constructed of knitted nonabsorbable polypropylene filaments. Both the subject and predicate devices function in the same manner and are designed for the repair of abdominal wall hernia defects, including inguinal (direct & indirect). There are no changes to the manufacturing, packaging, and sterilization processes, or shelf life of the currently marketed device. The subject PROLENETM Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh and PROLENE™ (Polypropylene) Hernia System, Nonabsorbable Synthetic Surgical Mesh, for which this 510(k) Premarket Notification- Change being Effected is being submitted, differs from the currently marketed devices, K962530 and K984220, in the labeling (Instructions for Use). The Instructions for Use has been revised to add a new Contraindication. Additionally, several other sections of the Instructions for Use of the subject devices have been reworded/ reformatted for clarity to address evolving regulatory expectations and bring the contents of the Instructions for Use up to date. ## Substantial Equivalence: PROLENE™ Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh is substantially equivalent to the PROLENE™ Polypropylene Mesh Nonabsorbable Synthetic Surgical Mesh (K962530) predicate device. Both the subject and predicate devices are constructed of knitted filaments of extruded polypropylene identical in composition to that used in PROLENE™ Polypropylene Suture, nonabsorbable surgical sutures. The principle of operation of the subject PROLENE™ Mesh, which is to provide reinforcement to repair abdominal wall hernias and abdominal wall deficiencies, is equivalent to that of the predicate device. The subject device is manufactured within the existing manufacturing processes for the predicate device. There are no changes to the packaging, sterilization processes, or shelf life of the currently marketed device. PROLENE™ (Polypropylene) Hernia System, Nonabsorbable Synthetic Surgical Mesh is substantially equivalent to the PROLENE™ (Polypropylene) Hernia {7}------------------------------------------------ System, Nonabsorbable Synthetic Surgical Mesh (K984220) predicate device. Both the subject and predicate devices are sterile, pre-shaped, three-dimensional devices constructed of an onlay patch connected by a mesh cylinder to a circular or oblong underlay patch. The material is undyed PROLENE™ (Polypropylene) mesh constructed of knitted nonabsorbable polypropylene filaments. The principle of operation of the subject PROLENE™ (Polypropylene) Hernia System, which is to provide reinforcement to repair abdominal wall hernia defects, including inguinal (direct & indirect) hernias, is equivalent to that of the predicate device. There are no changes to the manufacturing, packaging, and sterilization processes, or shelf life of the currently marketed device. The subject PROLENE™ Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh and PROLENE™ (Polypropylene) Hernia System, Nonabsorbable Synthetic Surgical Mesh differ from their respective predicate devices, K962530 and K984220, in the labeling (Instructions for Use). The Instructions for Use has been revised to add a new Contraindication. Additionally, several other sections of the Instructions for Use of the subject devices have been reworded/ reformatted for clarity to address evolving regulatory expectations and bring the contents of the Instructions for Use up to date. The Indication statement of the subject devices has been modified to add clarity and does not introduce any new indications or expand patient population of the predicate device. #### Conclusion: Based on the intended use, fundamental scientific technology and, technological characteristics, the subject devices PROLENE™ Polypropylene Mesh Non-Absorbable Synthetic Surgical Mesh and PROLENE™ (Polypropylene) Hernia System, Nonabsorbable Synthetic Surgical Mesh are considered to be substantially equivalent to their predicate devices, K962530 and K984220 respectively.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...