GALLINI BYCUT NEEDLE

K990716 · Gallini U.S., LLC · KNW · May 17, 1999 · Gastroenterology, Urology

Device Facts

Record IDK990716
Device NameGALLINI BYCUT NEEDLE
ApplicantGallini U.S., LLC
Product CodeKNW · Gastroenterology, Urology
Decision DateMay 17, 1999
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.1075
Device ClassClass 2

Intended Use

The Gallini Bycut Needle is used for bone biopsy.

Device Story

The Gallini Bycut® Bone Biopsy Needle is a manual surgical instrument used by clinicians to obtain bone tissue samples. The device functions as a biopsy needle, designed to penetrate bone tissue to extract a core sample for diagnostic purposes. It is intended for use in a clinical or hospital setting by qualified medical professionals. The output is a physical bone tissue specimen, which the physician uses to perform histological or pathological analysis to aid in the diagnosis of bone-related conditions. The device provides a minimally invasive method for tissue acquisition, facilitating clinical decision-making regarding patient treatment plans.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Manual bone biopsy needle. Device is a mechanical surgical instrument. No electronic components, software, or energy sources. Sterilization method not specified.

Indications for Use

Indicated for patients requiring bone biopsy procedures.

Regulatory Classification

Identification

A gastroenterology-urology biopsy instrument is a device used to remove, by cutting or aspiration, a specimen of tissue for microscopic examination. This generic type of device includes the biopsy punch, gastrointestinal mechanical biopsy instrument, suction biopsy instrument, gastro-urology biopsy needle and needle set, and nonelectric biopsy forceps. This section does not apply to biopsy instruments that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features a stylized eagle with three stripes extending from its head, symbolizing health, services, and people. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 MAY 17 1999 Mr. Paul L. Hawthorne U.S. Representative Galini U.S. , LLC 3991 Glenside Drive, Suite F Richmond, Virginia 23229 Re: K990716 Trade Name: Gallini Bycut® Bone Biopsy Needle Regulatory Class: II Product Code: KNW Dated: March 4, 1999 Received: March 4, 1999 Dear Mr. Hawthorne: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (OS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (OS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {1}------------------------------------------------ ## Page 2 – Mr. Paul L. Hawthorne This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4595. Additionally, for questions on the promotion and advertising of vour device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely yours, Sincerely yours, Celia M. Witten, Ph.D., M.D. Director Division of General and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ Page _1 of _1 | 510(k) Number (if known) | K990216 | |--------------------------|---------------| | Device Name: | Bycut® Needle | Indications for Use: (Per 21 CFR 801.109) The Gallini Bycut Needle is used for bone biopsy. (Please DO NOT WRITE BELOW THIS LINE—CONTINUE ON ANOTHER PAGE IF NEEDED.) Concurrence of CDRH, Office of Device Evaluation (ODE) | (Division Sign-Off) | | |-----------------------------------------|---------| | Division of General Restorative Devices | | | 510(k) Number | K990716 | | Prescription Use | <div style="text-align:center;">OR</div> | Over-the-Counter Use | |------------------|------------------------------------------|----------------------| |------------------|------------------------------------------|----------------------| (Optional Format 1-2-96)
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...