da Vinci SP Surgical System, EndoWrist SP Instruments, and Accessories
K173906 · Intuitive Surgical, Inc. · NAY · May 31, 2018 · Gastroenterology, Urology
Device Facts
Record ID
K173906
Device Name
da Vinci SP Surgical System, EndoWrist SP Instruments, and Accessories
Applicant
Intuitive Surgical, Inc.
Product Code
NAY · Gastroenterology, Urology
Decision Date
May 31, 2018
Decision
SESU
Submission Type
Traditional
Regulation
21 CFR 876.1500
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
To assist in the accurate control of endoscopic instruments in minimally invasive surgery.
Device Story
The da Vinci SP Surgical System (Model SP1098) is a software-controlled, electromechanical system for single-port minimally invasive urologic surgery. It comprises a Surgeon Console, Patient Cart, and Vision Cart. The surgeon operates from the console using master controls and foot pedals, viewing a 3D endoscopic image. The Patient Cart, positioned over the patient, features a single arm with four instrument drives; it holds a camera and up to three EndoWrist SP instruments. These instruments feature articulating distal tips mimicking human wrist/elbow/shoulder movement to enable triangulation through a single incision. The system uses a master/slave servomechanism for instrument control. The Vision Cart includes an integrated EnergyShield monitor for monopolar energy monitoring. The device is used in hospital operating rooms by trained physicians to perform tasks like suturing, dissection, and electrocautery, potentially improving surgical precision and access in confined spaces compared to traditional methods.
Clinical Evidence
No clinical testing provided. Evidence consists of bench performance testing (mechanical/electrical verification), cadaver studies (n=6), and porcine models (n=3) to validate anatomical access, reach, and surgical task performance (e.g., pyeloplasty, nephrectomy, prostatectomy). Human factors validation study conducted with 15 surgical teams and 15 prep teams in a simulated OR environment to assess safety, usability, and risk mitigation.
Technological Characteristics
Electromechanical, software-controlled master/slave servomechanism. Components: Surgeon Console, Patient Cart, Vision Cart with EnergyShield monitor. Instruments: Reusable, articulating EndoWrist SP (graspers, scissors, needle drivers). Connectivity: Networked system components. Sterilization: Validated for reusable instruments. Materials: Various medical-grade materials per ISO 10993-1. Standards: AAMI/ANSI ES60601-1, IEC 60601-2-2, IEC 60601-2-18, IEC 62304.
Indications for Use
Indicated for adult use by trained physicians in an operating room environment for urologic surgical procedures appropriate for a single port approach. Includes use of flexible endoscopes, dissectors, scissors, forceps, needle holders, retractors, and electrocautery for tissue manipulation, grasping, cutting, dissection, approximation, ligation, and suturing.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
In combination with the general controls of the FD&C Act, the integrated operating table-electromechanical surgical system is subject to the following special controls:
1. (1) Premarket clinical performance testing, or a combination of premarket clinical performance testing and postmarket surveillance (in accordance with special control (2)), must include the following:
1. (i) Objective performance measures (e.g., rate and number of conversions to other surgical modalities, rate of device related adverse events (including tissue injury, hematoma, and increased blood loss), and their severity, cause, and outcomes) must be reported with relevant descriptive comparator performance measures.
2. (ii) The data must demonstrate the performance of the device for providing accurate and precise control of attached surgical instruments in range of clinical conditions relevant to the device's intended use.
3. (iii) The test dataset must include data collected from a patient population representative of the intended patient population under anticipated conditions of use.
2. (2) Data obtained from postmarket surveillance must demonstrate, in consideration of the premarket data obtained in accordance with special control (1), that the device performs in accordance with special control (1), unless FDA determines, based on the totality of the premarket data, that data from postmarket surveillance is not required to demonstrate that the device performs as intended. Such postmarket surveillance must be conducted per a protocol determined appropriate by FDA to demonstrate that the device performs as intended (in consideration of the premarket data obtained in accordance with special control (1)), and must include initiation, enrollment, and reporting requirements to ensure timely periodic updates to FDA on post-market surveillance progress and outcomes.
3. (3) Animal performance testing must evaluate the extent of port site trauma due to repositioning of table during surgical procedures when utilizing robotic minimally invasive and laparoscopic approaches
4. (4) The device manufacturer must develop, and update as necessary, a device-specific use training program that ensures proper device setup/use/shutdown, accurate control of instruments to perform the intended surgical procedures, troubleshooting and handling during unexpected events or emergencies, and safe practices to mitigate use error.
5. (5) The device manufacturer may only distribute the device to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program.
(6) Human factors assessment must demonstrate that the user can correctly use the device system across all intended use environments with the provided instructions and training materials, including patient access during normal operating conditions and emergency situations, and effects arising from the integrated nature of the operating table and robotic surgical arms.
(7) Labeling must include:
(i) A detailed summary of clinical performance testing conducted with the device, including study population, results, adverse events, and comparisons to any comparator groups identified;
(ii) A statement in the labeling that the safety and effectiveness for the representative specific procedures was based on evaluation of the device as a surgical tool and did not include evaluation of outcomes related to the treatment of the patient's underlying disease or condition, unless FDA determines that it can be removed or modified based on clinical performance data submitted to FDA;
(iii) Identification of compatible devices;
(iv) The list of surgical procedures for which the device has been determined to be safe with clinical justification;
(v) Reprocessing instructions for reusable components;
(vi) A shelf life for any sterile components;
(vii) A description of the device-specific use training program;
(viii) A statement that the device is only for distribution to facilities that implement and maintain the device-specific use training program and ensure that users of the device have completed the device-specific use training program; and
(ix) A summary of any completed postmarket surveillance data collected as required by special control (2), including updated labeling to accurately reflect outcomes observed in postmarket surveillance.
(8) Non-clinical performance testing must demonstrate that the device performs as intended under anticipated conditions of use and must include:
(i) Device motion accuracy and repeatability;
(ii) System testing;
(iii) Instrument reliability;
(iv) Crosstalk;
(v) Table motion control;
(vi) Thermal effects on tissue;
(vii) User-device interface performance;
(viii) Workspace access testing; and
(ix) Performance testing with compatible devices.
(9) Software verification, validation, and hazard analysis must be performed.
(10) Electromagnetic compatibility and electrical, thermal, and mechanical safety testing must be performed.
(11) Performance data must demonstrate the sterility of all patient-contacting device components.
(12) Performance data must support the shelf life of the device components provided sterile by demonstrating continued sterility and package integrity over the labeled shelf life.
(13) Performance data must validate the reprocessing instructions for the reusable components of the device.
(14) Performance data must demonstrate that all patient-contacting components of the device are biocompatible.
(15) Performance data must demonstrate that all patient-contacting components of the device are non-pyrogenic.
(16) The device manufacturer must submit a report to the FDA annually on the anniversary of initial marketing authorization for the device, until such time as FDA may terminate such reporting, which comprises the following information:
(i) Cumulative summary, by year, of complaints and adverse events since date of initial marketing authorization; and
(ii) Identification and rationale for changes made to the device, labeling, or device specific use training program, which did not require submission of a premarket notification during the reporting period.
Predicate Devices
da Vinci SP Surgical System, Model SP999, EndoWrist SP Instruments, and Accessories (K131962)
Reference Devices
Intuitive Surgical da Vinci Xi Surgical System, Model IS4000 (K131861, K152892, K161271)
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo features the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text.
May 31, 2018
Intuitive Surgical, Inc. Elaine Lee Senior Regulatory Engineer 1266 Kifer Road Sunnyvale, California 94086
Re: K173906
Trade/Device Name: da Vinci SP Surgical System, EndoWrist SP Instruments, and Accessories Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope and Accessories Regulatory Class: Class II Product Code: NAY Dated: April 26, 2018 Received: April 27, 2018
Dear Elaine Lee:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976. the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act and the limitations described below. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
The Office of Device Evaluation has determined that there is a reasonable likelihood that this device will be used for an intended use not identified in the proposed labeling and that such use could cause harm. Therefore, in accordance with Section 513(i)(1)(E) of the Act, the following limitation must appear in the Precautions/Warnings/Contraindications section of the device's labeling:
The safety and effectiveness of this device for use in the performance of general laparoscopic surgery procedures have not been established. This device is only intended to be used for single port urological procedures with the da Vinci EndoWrist SP Instruments and the da Vinci SP Surgical System (SP1098).
Please note that the above labeling limitations are required by Section 513(i)(1)(E) of the Act. Therefore, a new 510(k) is required before these limitations are modified in any way or removed from the device's labeling.
{1}------------------------------------------------
The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and permits your device to the market. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification if the limitation statement described above is added to your labeling.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.html for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely.
William H. Maisel -S
William H. Maisel. MD. MPH Director Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
#### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
Indications for Use
Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2020 See PRA Statement below.
### 510(k) Number (if known) K173906
Device Name
da Vinci SP® Surgical System, Model SP1098, EndoWrist SP™ Instruments, and Accessories
#### Indications for Use (Describe)
da Vinci SP® Surgical System, Model SP1098:
The Intuitive Surgical® Endoscopic Instrument Control System (da Vinci SP® Surgical System, Model SP1098) is intended to assist in the accurate control of Intuitive Surgical EndoWrist SP™ Instruments during urologic surgical procedures that are appropriate for a single port approach. The system is indicated for use by trained physicians in an operating room environment in accordance with the representative, specific procedures set forth in the Professional Instructions for Use.
### EndoWrist SPTM Instruments:
Intuitive Surgical® EndoWrist SP™ Instruments are controlled by the da Vinci SP® Surgical System, Model SP1098, and include flexible endoscopes, blunt and sharp endoscopic dissectors, scissors, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, and suturing through a single incision laparoach. The system is indicated for urologic surgical procedures that are appropriate for a single port approach. The system is indicated for adult use. It is intended for use by trained physicians in an operating room environment in accordance with the representative, specific procedures set forth in the Professional Instructions for Use.
Type of Use (Select one or both, as applicable)
> Prescription Use (Part 21 CFR 801 Subpart D)
] Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
FORM FDA 3881 (7/17)
{3}------------------------------------------------
# 510(k) Summary
| 510(k) Owner: | Intuitive Surgical, Inc.<br>1266 Kifer Road<br>Sunnyvale, CA 94086 |
|---------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------|
| Contact: | Elaine Lee<br>Senior Regulatory Engineer<br>Phone Number: 408-523-8887<br>Fax Number: 408-523-8907<br>Email: Elaine.Lee@intusurg.com |
| Date Summary Prepared: | May 29, 2018 |
| Trade Name: | da Vinci SP® Surgical System, Model SP1098,<br>EndoWrist SPTM Instruments, and Accessories |
| Common Name: | Endoscopic instrument control system, endoscopic<br>instruments and accessories |
| Classification: | Class II<br>21 CFR 876.1500, Endoscope and Accessories |
| Product Codes: | NAY (System, Surgical, Computer Controlled Instrument) |
| Classification Advisory<br>Committee: | General and Plastic Surgery |
| Predicate Device: | da Vinci SP Surgical System, Model SP999, EndoWrist SP<br>Instruments, and Accessories (K131962) |
| Reference Device: | Intuitive Surgical da Vinci Xi Surgical System, Model<br>IS4000 (K131861, K152892, K161271) |
# Device Description
The da Vinci SP Surgical System, Model SP1098 is a software-controlled, electromechanical system designed for surgeons to perform single port minimally invasive surgery. The Model SP1098 Surgical System consists of a Surgeon Console, a Patient Cart, and a Vision Cart, and is used with a Camera Instrument, EndoWrist SP Instruments, and Accessories.
{4}------------------------------------------------
Image /page/4/Picture/2 description: The image shows three pieces of medical equipment against a white background. The first piece of equipment is a surgical console with a large, gray viewing hood and robotic arm controls. The second piece of equipment is a robotic surgical arm with multiple joints and a base. The third piece of equipment is a medical cart with a monitor, shelves, and drawers.
Surgeon Console, Model SS1098
Patient Cart, Model PS1098
Vision Cart, Model VS1098
The surgeon seated at the Surgeon Console controls all movement of the EndoWrist SP Instruments and Camera Instrument by using two Master Controls and a set of foot pedals. The surgeon views the three-dimensional endoscopic image on a High Resolution Stereo Viewer (3D Viewer), which provides him/her a view of patient anatomy and instrumentation, along with icons and other user interface features.
The Vision Cart includes the supporting electronic and video processing equipment for the system.
The Patient Cart is positioned at the operating room table and has four instrument drives on a single arm that is positioned over the target patient anatomy. A Camera Instrument attaches onto one instrument drive and provides the surgeon a high resolution, threedimensional view of the patient anatomy. A suite of EndoWrist SP Instruments can be attached to and detached from the other three instrument drives, enabling the surgeon to perform various surgical tasks. The Camera Instrument and up to three surgical instruments can be used simultaneously, entering the patient through a single port. Accessories including a cannula, an obturator, a seal, an entry guide, disposable tips for selected instruments, instrument sheaths, and a drape are needed to perform procedures with the system.
The EndoWrist SP Instruments come in various configurations such as graspers, scissors, and needle drivers. The EndoWrist SP instruments have a unique articulating design at the distal tip that mimics the human wrist, shoulder, and elbow to enable triangulation and X-Y-Z movement of the instrument in the body. Each instrument is used to perform specific surgical tasks such as grasping, suturing, tissue manipulation, and electrocautery. The EndoWrist SP Instruments can be used only with the SP1098 Surgical System. The instruments are reusable. They are programmed with a maximum number of surgical procedures based upon life testing.
{5}------------------------------------------------
The EndoWrist SP Camera Instrument is a reusable endoscope that provides a stereo image of the surgical site. Like the instruments, the distal end includes multiple joints that provide the flexibility needed for use with a single-port system.
The following EndoWrist SP Instruments and accessories are listed for use with the da Vinci SP Surgical System, Model SP1098:
EndoWrist SP Instruments:
- Fenestrated Bipolar Forceps .
- . Maryland Bipolar Forceps
- . Medium-Large Clip Applier (a.k.a. ML Clip Applier)
- Monopolar Cautery Instrument .
- Monopolar Curved Scissors (a.k.a. MCS) ●
- Needle Driver ●
- . Round Tooth Retractor
- Cadiere Forceps ●
- EndoWrist SP Camera, 0° (a.k.a. Camera Instrument) ●
Accessories for the SP1098 da Vinci SP Surgical System:
- SP Cannula, Circular, 25 x 100 mm (a.k.a. Cannula) .
- . SP Obturator, Circular, 25 x 100 mm (a.k.a. Obturator)
- EntryGuide Kit C.6.6.6, 25 x 100 mm (a.k.a. Entry Guide and Cannula . Seal)
- Instrument Sheath .
- Camera Sheath
- MCS Tip ●
- Cautery Hook Tip ●
- Cautery Spatula Tip .
- Bipolar Cautery Cord .
- EnergyShield Monopolar Cautery Cord
- Instrument Arm Drape (a.k.a. Drape) ●
# Intended Use:
To assist in the accurate control of endoscopic instruments in minimally invasive surgery.
{6}------------------------------------------------
# Indications for Use:
# da Vinci SP® Surgical System, Model SP1098
The Intuitive Surgical® Endoscopic Instrument Control System (da Vinci SP® Surgical System, Model SP1098) is intended to assist in the accurate control of Intuitive Surgical EndoWrist SP™ Instruments during urologic surgical procedures that are appropriate for a single port approach. The system is indicated for adult use. It is intended for use by trained physicians in an operating room environment in accordance with the representative, specific procedures set forth in the Professional Instructions for Use.
# EndoWrist SP™ Instruments
Intuitive Surgical® EndoWrist SP™ Instruments are controlled by the da Vinci SP® Surgical System, Model SP1098, and include flexible endoscopes, blunt and sharp endoscopic dissectors, scissors, forceps/pick-ups, needle holders, endoscopic retractors, electrocautery and accessories for endoscopic manipulation of tissue, including grasping, cutting, blunt and sharp dissection, approximation, ligation, electrocautery, and suturing through a single incision laparoscopic approach. The system is indicated for urologic surgical procedures that are appropriate for a single port approach. The system is indicated for adult use. It is intended for use by trained physicians in an operating room environment in accordance with the representative, specific procedures set forth in the Professional Instructions for Use.
# Comparison of Technological Characteristics with the Predicate Device:
The da Vinci SP Surgical System, Model SP1098 is equivalent to the predicate device, Model SP999 (K131962), in terms of technological characteristics, and has identical indications for use. Like the Model SP999, the Model SP1098 is designed for use in single incision laparoscopic procedures.
The Model SP1098 is a modification of the Model SP999 (K131962). The Vision Cart, Surgeon Console, and Patient Cart were modified to incorporate the latest mechanical, electrical, and user interface technology of the cleared multi-port da Vinci Xi Surgical System, Model IS4000 (K131861, as modified by K152892 and K161271). An integrated monopolar energy monitor was also added to the Vision Cart. Modifications were also made to the EndoWrist SP Instruments and Accessories to improve manufacturability, robustness/reliability, cleaning ability, and ease of use while enhancing safety and maintaining the same ability to perform surgical tasks. In order to accommodate the modified instruments and to improve ease of use, the Instrument Arm and Instrument Drives were updated as well.
{7}------------------------------------------------
| Attribute | Subject Device<br>SP1098 da Vinci SP Surgical System,<br>Instruments, and Accessories | Predicate Device<br>SP999 da Vinci SP Surgical System,<br>Instruments, and Accessories (K131962) |
|-----------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device types | System Carts:<br>• Surgeon Console<br>• Vision Cart, including the<br><i>EnergyShield</i> Monitor<br>• Patient Cart<br>Instruments:<br>• Fenestrated Bipolar Forceps<br>• Maryland Bipolar Forceps<br>• Medium-Large Clip Applier<br>• Monopolar Cautery Instrument<br>• Monopolar Curved Scissors<br>• Needle Driver<br>• Round Tooth Retractor<br>• Cadiere Forceps<br>Endoscope:<br>• Camera Instrument<br>Accessories:<br>• Cannula<br>• Entry Guide<br>• Cannula Seal<br>• Obturator<br>• Instrument Sheath<br>• Camera Sheath<br>• <i>Energy Shield</i> Monopolar Cautery<br>Cord<br>• Drape<br>• MCS Tip | SAME types of system carts as subject<br>device.<br>SAME types of available instruments<br>and endoscope as subject device.<br>Note: The SP999 instruments did not<br>include a Round Tooth Retractor or<br>Cadiere Forceps; however, the SP999<br>Fenestrated Bipolar Forceps is the<br>predicate device for these new<br>instruments.<br>SAME types of accessories as subject<br>device, plus the AEM (Active Electrode<br>Monitor).<br>Note: The Active Electrode Monitor and<br>Monopolar Cautery Cord used with the<br>SP999 system were third-party devices. |
| Common Name | Endoscopic instrument control system,<br>endoscopic instruments and accessories | SAME as subject device |
| Attribute | Subject Device<br>SP1098 da Vinci SP Surgical System,<br>Instruments, and Accessories | Predicate Device<br>SP999 da Vinci SP Surgical System,<br>Instruments, and Accessories (K131962) |
| Regulation<br>Number & Name | 21 CFR 876.1500<br>Endoscope and Accessories | SAME as subject device |
| Classification<br>Advisory<br>Committee | General and Plastic Surgery | SAME as subject device |
| Product Code(s) | NAY (System, Surgical, Computer<br>Controlled Instrument) | SAME as subject device |
| Classification | Class II | SAME as subject device |
| Intended Use | To assist in the accurate control of<br>endoscopic instruments in minimally<br>invasive surgery. | SAME as subject device |
| Principles of<br>Operation | Facilitates accurate movement of surgical<br>instruments and an endoscope through a<br>single surgical port by using a<br>master/slave servomechanism that<br>incorporates servo drive and system-level<br>motor control. | SAME as subject device |
| Prescription Use | Physician use only | SAME as subject device |
| Where Used | Hospital | SAME as subject device |
{8}------------------------------------------------
{9}------------------------------------------------
# Performance Data:
Performance test data (bench, animal, and cadaver tests) demonstrate that the subject device is substantially equivalent to the predicate device and that the design output meets the design input requirements. The testing included dimensional measurements, mechanical and functional verification, electrical safety, and simulated use in animal and cadaver models as follows. For some components or subassemblies that are identical to those in the Model SP999 or the Model IS4000. design verification relied on previous testing.
## Bench Performance Testing
The SP1098 (da Vinci SP) Patient Cart and subassemblies were subjected to full design verification to mechanical and electrical specifications. A summary of the design verification testing for the Patient Cart, the Instrument Arm, and the Instrument Drives is described below:
| Item | Testing |
|------------------|------------------------------------|
| Patient Cart | Brake forces |
| | Safety |
| | Lower-risk mechanical requirements |
| | Miscellaneous design features |
| | External testing |
| Instrument Arm | Applied loads |
| | Interfaces |
| | Mechanical design |
| | Electrical requirements |
| | Safety |
| Instrument Drive | Mechanical |
| | Chassis ground |
| | Reliability |
The SP1098 Surgeon Console is identical to the IS4000 (da Vinci Xi) Surgeon Console except for modifications to the foot pedals. Verification testing was performed to confirm that the modifications meet electrical and mechanical specifications, as summarized below:
| Item | Testing |
|-----------------|------------------------------------------|
| Surgeon Console | Mechanical stability |
| | Cosmetic and labeling requirements |
| Foot Pedals | Pedal labels and layout |
| | Pedal reliability |
| | Mechanical and electrical specifications |
| | Sensors |
{10}------------------------------------------------
The SP1098 Vision Cart is identical to the IS4000 Vision Cart except for the addition of the EnergyShield Monitor. Verification testing was performed to confirm that this modification meets electrical and mechanical specifications, and design verification testing was performed for the EnergyShield Monitor, as summarized below:
| Item | Testing |
|-----------------------|---------------------------------------------------------|
| Vision Cart | Mechanical and electrical requirements |
| | Safety |
| EnergyShield® Monitor | Physical specifications (physical features, layout) |
| | Equipment interfaces (mechanical, electrical, cleaning) |
| | Electrical requirements |
| | Electrical safety |
| | Environmental requirements |
| | Labeling |
Testing was performed on each instrument type to verify that the design meets physical, mechanical, user interface, and equipment interface requirements. A summary of the design verification testing for the SP1098 surgical instruments and camera is described below:
| Item | Testing |
|----------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Camera | Physical specifications (size, weight, materials)<br>Mechanical requirements (force, range of motion,<br>accuracy)<br>Equipment interfaces (mechanical, electrical, cleaning,<br>software)<br>Electrical and patient safety<br>Image quality<br>Labeling |
| Surgical Instruments | Physical specifications (dimensions, weight, materials)<br>Mechanical requirements (force, range of motion,<br>accuracy)<br>Equipment interfaces (mechanical, electrical, cleaning,<br>software)<br>User interface and patient safety<br>Re-use and reliability<br>Environmental requirements<br>Shipping and storage<br>Package and labeling |
A summary of the design verification testing for the SP1098 accessories is described below:
{11}------------------------------------------------
| Item | Testing |
|-------------------------|---------------------------------------------------|
| Cannula, Obturator, | Physical specifications (size, weight, materials) |
| EntryGuide™ Kit, | Mechanical and electrical requirements |
| Instrument Sheath, | Equipment interfaces |
| Camera Sheath, MCS | Re-use and reliability |
| Tip, EnergyShield® | Package and labeling |
| Monopolar Cautery Cord, | |
| Instrument Arm Drape | |
# Cadaver and Animal Performance Testing -
Cadaver models were used to demonstrate device performance for anatomical access and reach. Live animal models were used to assess safety and performance in cases where a live tissue model was appropriate. These models replicate factors experienced during use, including working with perfused organs, bleeding, normal tissue handling, and ensuring that appropriate hemostasis is achieved and maintained. Nine procedures were performed (6 cadaver, 3 porcine) to evaluate and validate the performance of the overall SP1098 system. Procedures were chosen on the basis of the types of surgical tasks that are performed, and which EndoWrist SP instruments are needed for the tasks.
| Procedure | Subject | Performance Evaluated in Procedure |
|------------------------------------------------------------------------------------------------------------|---------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Pelvic lymphadenectomy | Cadaver | Enables evaluation of pelvic access and ability to precisely<br>dissect around vessels. |
| Colectomy (Right and Left) | Cadaver | Requires access to multiple quadrants of the body, allowing<br>evaluation of the system's range of motion and ability to work<br>in a large work volume. Instrument and grip strength during<br>retraction can also be assessed. |
| Radical Prostatectomy | Cadaver | Allows assessment of the ability to access the deep pelvis in a<br>male model and suture in a confined space. |
| Pyeloplasty | Cadaver | Enables assessment of renal access and the ability to precisely<br>suture small/thin tissues. |
| Total Nephrectomy | Cadaver | Enables evaluation of renal access, fine dissection ability<br>during renal hilum dissection, and instrument strength and<br>range of motion during mobilization of the kidney. |
| Partial Nephrectomy | Cadaver | Enables evaluation of fine dissection ability around vascular<br>structures, suturing of delicate tissue, and evaluation of needle<br>handling in a variety of orientations. |
| Partial nephrectomy (renal<br>hilum dissection and<br>clamping, specimen<br>resection, and defect closure) | Porcine | Enables evaluation of fine dissection in live tissue and<br>suturing of delicate tissue. Additionally, allows evaluation of<br>needle handling in a variety of orientations. |
| Renal artery ligation,<br>transection, and anastomosis | Porcine | Enables evaluation of the ability to effectively ligate blood<br>vessels and to transect thin tissue, as well as precisely suture<br>and manipulate small anatomy. |
| Bladder neck dissection,<br>transection, and<br>urethrovesical anastomosis | Porcine | Allows assessment of the ability to dissect deep in the pelvis<br>as well as to transect, manipulate, and suture thick tissue.<br>Additionally, enables evaluation of needle handling in a<br>variety of orientations. |
{12}------------------------------------------------
Three (3) independent practicing surgeons participated in a study using the SP1098 system to perform a set of urologic procedures. Each surgeon performed seven urologic procedures in a cadaver model and five representative and simulated procedures in a porcine model, for a total of 36 surgical procedures performed. The order that the procedures were performed was randomized. Success criteria for each procedure are listed below. In addition, surgeons completed questionnaires that evaluated their ability to perform surgical tasks with the SP1098 system.
| Procedure | Subject | Success Criteria |
|------------------------------------------------------|---------|------------------------------------------------------------------------------------------------------------------------------------------------|
| Left pyeloplasty | Cadaver | Anastomosis complete and deemed acceptable upon visual inspection. |
| Right pyeloplasty | Cadaver | Critical anatomy identified. |
| Left total nephrectomy | Cadaver | Kidney completely freed from all surrounding tissues. Critical anatomy identified. |
| Right total nephrectomy | Cadaver | Kidney completely freed from all surrounding tissues. Critical anatomy identified. |
| Prostatectomy | Cadaver | Prostate is removed. Urethrovesical anastomosis is complete and deemed acceptable upon visual inspection. Critical anatomy identified. |
| Left pelvic lymphadenectomy | Cadaver | Lymph nodes freed from vessels. Critical anatomy identified and dissection borders achieved. |
| Right pelvic lymphadenectomy | Cadaver | Lymph nodes freed from vessels. Critical anatomy identified and dissection borders achieved. |
| Pyeloplasty | Porcine | Ureter anastomosis is complete and deemed acceptable upon visual inspection. Hemostasis is maintained. |
| Partial nephrectomy | Porcine | 2 cm diameter defect is removed. Defect is closed such that hemostasis is maintained. |
| Total nephrectomy | Porcine | Renal vein and artery successfully ligated. Entire kidney freed from all attachments. Hemostasis is maintained. |
| Bladder neck mobilization, division, and anastomosis | Porcine | 3 cm length of bladder neck/urethra mobilized. Anastomosis is complete and deemed acceptable upon visual inspection. Hemostasis is maintained. |
| Pelvic lymphadenectomy | Porcine | Lymph node freed from surrounding tissue. Hemostasis is maintained. |
# Clinical Studies -
No clinical testing was provided with this submission using the subject device to support substantial equivalence.
# Human Factors Performance Testing -
A human factors (HF) engineering process was followed in accordance with the following:
- . ANSI/AAMI/IEC 62366-1:2015, Medical devices - Application of usability engineering to medical devices
- FDA, 2016, Applying Human Factors and Usability Engineering to Medical . Devices - Guidance for Industry and Food and Drug Administration Staff
{13}------------------------------------------------
The SP1098 usability risk analysis was developed with feedback from internal functional group experts, using cognitive walk-through, experience from prior products, and internal testing to identify use-related risks. This usability risk analysis was updated throughout the design process as formative testing was conducted, system design was iterated, new use errors were identified, and new mitigations were implemented. Formative testing was conducted both on complete system prototypes and on individual features of the user interface design. Those tests, along with information about the use of the da Vinci Xi Surgical System (Model IS4000), with which the SP1098 shares some design features, helped identify use-related risks for the SP1098 system.
A summative validation study was conducted to evaluate high-risk use scenarios and essential tasks that were not assessed in previous usability validations. This study was conducted in a simulated operating room and involved preoperative preparation and simulated surgical procedures, as well as emergency procedures that involved safetycritical tasks. Training materials and user manuals were developed in concert with the product hardware and software, and were assessed in the validation study. The goals of human factors validation testing were to:
- . Validate risk mitigations to ensure use-safety and effectiveness of the system
- Assess any previously unknown use-related hazards, or identify and assess any . hazards resulting from implemented mitigations
- Evaluate ease of use .
- Assess effectiveness of user documentation .
- Assess effectiveness of training material .
A total of 15 surgical teams (surgeon and patient-side assistant) and 15 prep teams (scrub tech and circulating nurse) participated in the study. Participants underwent the training a user would be provided for the SP1098 system on the first day. The testing sessions were conducted in a simulated operating room environment. Participants were asked to use sterile technique within the surgical field. In addition to the normal use situation of performing the necessary surgical tasks to complete the procedures, imposed scenarios were interiected to test use scenarios that may not occur during normal operation of the system, such as responding to an EnergyShield Monitor fault. Data collected included both objective performance data and subjective feedback from participants. Objective performance data included observations of users' ability to complete tasks, use errors, close calls, and any difficulties encountered. Subjective feedback included open-ended questions about risks and safety, multiple choice ratings, and follow-up interviews.
The human factors engineering process, culminating in a summative usability validation study, was used to identify and assess the use-related risks associated with the SP1098
{14}------------------------------------------------
system. The safety and usability of the SP1098 were assessed to ensure that residual risk is at an acceptable level, and new hazardous use scenarios identified during testing were assessed according to an accepted risk management process and updated in the usability risk analysis for the SP1098 system.
# Consensus Standards and FDA Guidance Documents Used in Performance Testing:
- . AAMI/ANSI ES60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012 and A2:2010/(R)2012, Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance
- AAMI/ANSI/IEC 60601-2-2:2009, Medical Electrical Equipment Part 2-2: . Particular Requirements for the Basic Safety and Essential Performance of High Frequency Surgery Equipment and High Frequency Surgical Accessories
- . IEC 60601-2-18:2009, Medical Electrical Equipment - Part 2-18: Particular Requirements for the Basic Safety and Essential Performance of Endoscopic Equipment
- . IEC 60601-1-2 Edition 3:2007-03, Medical Electrical Equipment - Part 1-2: General Requirements for Basic Safety and Essential Performance
- . IEC 60825-1:2007, Safety of Laser Products - Part 1: Equipment Classification and Requirements
- . ANSI/AAMI/IEC 62366-1:2015, Medical devices - Application of Usability Engineering to Medical Devices
- IEC 62304:2015, Medical Device Software Software Life Cycle Processes ●
- AAMI/ANSI/ISO 10993-1:2009/(R)2013, Biological Evaluation of Medical . Devices - Part 1: Evaluation and Testing within a Risk Management Process
- . ISO 10993-7:2008. Biological Evaluation of Medical Devices - Part 7: Ethylene Oxide Sterilization Residuals
- . ISO 17665-1:2006, Sterilization Of Health Care Products - Moist Heat - Part 1: Requirements for the Development, Validation and Routine Control of a Sterilization Process for Medical Devices
- AAMI/ANSI/ISO 11137-1:2006/(R)2010, Sterilization of Health Care Products -. Radiation - Part 1
- ASTM D4169-16, Standard Practice for Performance Testing of Shipping . Containers and Systems
- . Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling. Guidance for Industry and Food and Drug Administration Staff, issued March 17, 2015.
- Premarket Notification (510(k)) Submissions for Electrosurgical Devices for . General Surgery. Guidance for Industry and Food and Drug Administration Staff, issued August 15, 2016.
{15}------------------------------------------------
- Applying Human Factors and Usability Engineering to Medical Devices. . Guidance for Industry and Food and Drug Administration Staff, issued February 3, 2016.
# Conclusion:
Based on the intended use, indications for use, technological characteristics and performance data, the Intuitive Surgical da Vinci SP Surgical System, Model SP1098, EndoWrist SP Instruments, and Accessories, is substantially equivalent (SE) to the predicate device. This SE determination is based on performance testing that included: bench, cadaver, and animal testing with simulated and representative urological procedures. The bench performance testing verified that the design requirements and specifications for the new and/or changed components of the system are met. The cadaver performance testing validated the users' ability to use the system to accurately control the endoscopic instruments, to reach the necessary target anatomy, and to perform surgical tasks. The simulated and representative urological procedures in live animals provided validation that the system can safely and effectively complete representative urologic procedures encompassed by the indications for use statement. Finally, the human factors assessment provided further assurance that risks due to user errors are identified and mitigated.
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only software-only devices, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (software-only devices), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.