STELKAST 32MM MODULAR CERAMIC FEMORAL HEAD

K033944 · Stelkast Company · LZO · Mar 12, 2004 · Orthopedic

Device Facts

Record IDK033944
Device NameSTELKAST 32MM MODULAR CERAMIC FEMORAL HEAD
ApplicantStelkast Company
Product CodeLZO · Orthopedic
Decision DateMar 12, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3353
Device ClassClass 2
AttributesTherapeutic

Intended Use

The 32mm Modular Ceramic Femoral Head is a single use device used for reconstruction of the articulating surface of the femoral head portion of the hip that is severely disabled and/or very painful resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis, avascular necrosis, or fracture of the femoral head.

Device Story

Modular ceramic femoral head component for hip arthroplasty; intended for reconstruction of articulating surface of femoral head. Device replaces damaged femoral head in patients with severe hip pain or disability due to arthritis, necrosis, or fracture. Used by orthopedic surgeons in clinical/surgical settings. Functions as mechanical bearing surface within hip joint prosthesis system. Benefits patient by restoring joint function and reducing pain.

Clinical Evidence

No clinical data provided; substantial equivalence based on technological characteristics and intended use.

Technological Characteristics

Modular ceramic femoral head; 32mm diameter; intended for hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis. Class II device (21 CFR 888.3353).

Indications for Use

Indicated for patients requiring hip reconstruction due to severe disability or pain from osteoarthritis, rheumatoid arthritis, traumatic arthritis, avascular necrosis, or femoral head fracture.

Regulatory Classification

Identification

A hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis is a device intended to be implanted to replace a hip joint. This device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. The two-part femoral component consists of a femoral stem made of alloys to be fixed in the intramedullary canal of the femur by impaction with or without use of bone cement. The proximal end of the femoral stem is tapered with a surface that ensures positive locking with the spherical ceramic (aluminium oxide, A12 03 ) head of the femoral component. The acetabular component is made of ultra-high molecular weight polyethylene or ultra-high molecular weight polyethylene reinforced with nonporous metal alloys, and used with or without bone cement.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the Department of Health & Human Services (HHS) of the United States of America. The logo features a stylized graphic of an eagle or bird-like figure with three curved lines representing its body and wings. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the graphic. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 MAR 1 2 2004 Donald A. Stevens President StelKast Company 200 Hidden Valley Road Mc Murray, Pennsylvania 15317 Re: K033944 Trade/Device Name: StelKast 32mm Modular Ceramic Femoral Head Regulation Number: 21 CFR 888.3353 Regulation Name: Hip joint metal/ceramic/polymer semi-constrained cemented or nonporous uncemented prosthesis Regulatory Class: II Product Code: LZO Dated: December 18, 2003 Received: December 19, 2004 Dear Mr. Stevens: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be adviscd that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {1}------------------------------------------------ Page 2 - Donald A. Stevens This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, L. Merle A. Wilkerson Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ | 510(K) Number (if known): | K033944 | |---------------------------|---------| |---------------------------|---------| StelKast 32mm Modular Ceramic Femoral Head Device Name: ## Indications For Use: The 32mm Modular Ceramic Femoral Head is a single use device used for reconstruction of the articulating surface of the femoral head portion of the hip that is severely disabled and/or very painful resulting from osteoarthritis, rheumatoid arthritis, traumatic arthritis, avascular necrosis, or fracture of the femoral head. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) ![signature](...)Mad A Milkus *for* (Division Sign-Off) Division of General, Restorative, and Neurological Devices | (k) Number | K033944 | |------------|---------| |------------|---------| | Prescription Use<br>(Per 21 CFR 801.109) | <img alt="check" src="..."/> | OR | Over-The-Counter Use | |------------------------------------------|------------------------------|----|----------------------| |------------------------------------------|------------------------------|----|----------------------| (Optional Format 1-2-96)
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...