FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
NDH
Nail, Fixation, Bone, Metallic
2
Product Code
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
3
Product Code
HSA
Prosthesis, Knee, Hemi-, Femoral
3
Product Code
HSB
Rod, Fixation, Intramedullary And Accessories
2
Product Code
NDI
Staple, Fixation, Bone, Metallic
2
Product Code
HRS
Plate, Fixation, Bone
2
Product Code
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
2
Product Code
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
2
Product Code
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
2
Product Code
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
2
Product Code
HTN
Washer, Bolt Nut
2
Product Code
HTY
Pin, Fixation, Smooth
2
Product Code
HWC
Screw, Fixation, Bone
2
Product Code
HXA
Prosthesis, Tendon, Passive
2
Product Code
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
2
Product Code
JDC
Prosthesis, Elbow, Constrained, Cemented
2
Product Code
JDD
Prosthesis, Upper Femoral
2
Product Code
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
2
Product Code
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
3
Product Code
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
2
Product Code
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
3
Product Code
JDN
Implant, Fixation Device, Spinal
2
Product Code
JDO
Device, Fixation, Proximal Femoral, Implant
2
Product Code
JDP
Condylar Plate Fixation Implant
2
Product Code
JDQ
Cerclage, Fixation
2
Product Code
JDR
Staple, Fixation, Bone
2
Product Code
JDS
Nail, Fixation, Bone
2
Product Code
JDT
Cap, Bone
1
Product Code
JDW
Pin, Fixation, Threaded
2
Product Code
JEC
Component, Traction, Invasive
2
Product Code
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
2
Product Code
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
2
Product Code
KIG
Prosthesis, Wrist, Constrained, Polymer
2
Product Code
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
2
Product Code
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
2
Product Code
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
3
Product Code
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
2
Product Code
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
3
Product Code
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
3
Product Code
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
2
Product Code
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
2
Product Code
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
2
Product Code
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
3
Product Code
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
3
Product Code
KWD
Prosthesis, Toe, Hemi-, Phalangeal
2
Product Code
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
3
Product Code
KWF
Prosthesis, Finger, Polymer
2
Product Code
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
3
Product Code
KWH
Prosthesis, Toe, Constrained, Polymer
2
Product Code
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
2
Product Code
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
3
Product Code
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
2
Product Code
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
2
Product Code
KWM
Prosthesis, Wrist, Semi-Constrained
2
Product Code
KWN
Prosthesis, Wrist, Carpal Lunate
2
Product Code
KWO
Prosthesis, Wrist, Carpal Scaphoid
2
Product Code
KWP
Appliance, Fixation, Spinal Interlaminal
2
Product Code
KWQ
Appliance, Fixation, Spinal Intervertebral Body
2
Product Code
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
3
Product Code
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
2
Product Code
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
2
Product Code
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
2
Product Code
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
2
Product Code
KXA
Prosthesis, Hip, Femoral, Resurfacing
2
Product Code
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
3
Product Code
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
3
Product Code
KXD
Prosthesis, Hip, Constrained, Metal
3
Product Code
KXE
Prosthesis, Wrist, Hemi-, Ulnar
2
Product Code
KYI
Prosthesis, Wrist, Carpal Trapezium
2
Product Code
KYJ
Prosthesis, Finger, Constrained, Polymer
2
Product Code
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
3
Product Code
KYN
Prosthesis, Wrist, Constrained, Metal
3
Product Code
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
3
Product Code
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
2
Product Code
LOD
Bone Cement
2
Product Code
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
2
Product Code
K
25
2067
Velora Acetabular System
2
Cleared 510(K)
K
25
1833
EMPOWR Acetabular® Liner Extension
2
Cleared 510(K)
K
25
1718
ArTT Augments and Buttresses and Bone Screws
2
Cleared 510(K)
K
25
0989
Stryker and Serf hip devices
2
Cleared 510(K)
K
24
3456
ONVOY™ Acetabular System
2
Cleared 510(K)
K
24
2744
Trinity EVO Acetabular Shell
2
Cleared 510(K)
K
24
2232
Mpact 3D Metal Augments II
2
Cleared 510(K)
K
24
2045
Initia T3 Acetabular Hemispherical Shell System
2
Cleared 510(K)
K
24
3784
Stryker Orthopaedics Hip Devices Labeling Update
2
Cleared 510(K)
K
24
3977
EMPHASYS Acetabular System
2
Cleared 510(K)
K
24
1059
Pantheon Proximal Femur Reconstruction (PFR) System
2
Cleared 510(K)
K
24
1636
MobileLink Acetabular Cup System - Line Extension (Multiple)
2
Cleared 510(K)
K
24
2833
Legend® Acetabular Shell
2
Cleared 510(K)
K
24
2375
OR3O Dual Mobility System
2
Cleared 510(K)
K
24
2084
EMPHASYS Acetabular Shell with RapiTite HA
2
Cleared 510(K)
K
24
0046
Ethylene Oxide Sterilization Supplier Change for MPO Hips
2
Cleared 510(K)
K
23
1522
EMPHASYS™ Dual Mobility System
2
Cleared 510(K)
K
23
3498
Stryker Orthopaedics Hip Systems Labeling Update
2
Cleared 510(K)
K
23
2667
OR3O Dual Mobility Liners
2
Cleared 510(K)
K
23
2556
DePuy 3D Additive TriFlange Acetabular Cup and DePuy TriFlange II Acetabular Cup System
2
Cleared 510(K)
K
23
0011
Mpact Extension
2
Cleared 510(K)
K
22
2436
Latitud™ Hip Replacement System
2
Cleared 510(K)
K
22
2066
LINK MobileLink Acetabular Cup System
2
Cleared 510(K)
K
22
3223
BENCOX Mirabo Z Cup Cortinium
2
Cleared 510(K)
K
22
3779
EMPOWR™ blade stem
2
Cleared 510(K)
K
22
3348
My3D® Personalized Pelvic Reconstruction
2
Cleared 510(K)
K
21
1047
CoCr Head
2
Cleared 510(K)
K
22
1675
United U2 femoral head, 22mm delta ceramic head
2
Cleared 510(K)
K
21
3842
ONVOY Acetabular System
2
Cleared 510(K)
K
22
0336
Mg-PSZ Ceramic Femoral Head
2
Cleared 510(K)
K
22
1636
EMPHASYS Acetabular System
2
Cleared 510(K)
K
22
0959
OR3O Dual Mobility System
2
Cleared 510(K)
K
21
2815
My3D® Personalized Pelvic Reconstruction
2
Cleared 510(K)
K
21
1176
Smith & Nephew Hip Systems
2
Cleared 510(K)
K
20
1348
DePuy 3D Additive TriFlange Acetabular Cup
2
Cleared 510(K)
K
21
0614
BENCOX Mirabo Z Cup Cortinium
2
Cleared 510(K)
K
22
0468
BENCOX Mirabo Cup System
2
Cleared 510(K)
K
21
2761
Biocore9 Acetabular Cup System
2
Cleared 510(K)
K
22
0376
Acetabular Dome Hole Plug
2
Cleared 510(K)
K
21
2187
Restoration® Modular Hip System
2
Cleared 510(K)
K
21
1330
R3 Large Head Liners
2
Cleared 510(K)
K
20
2568
Mpact® 3D Metal Implants - DMLS Technology
2
Cleared 510(K)
K
20
0011
E-CLASS® DUAL MOBILITY INSERTS and DYNASTY® DUAL MOBILITY LINERS
2
Cleared 510(K)
K
21
1866
Bencox THR System
2
Cleared 510(K)
K
20
1733
Provident II Hip Stems
2
Cleared 510(K)
K
20
0607
LINK MobileLink® Acetabular Cup System - Dual Mobility Liners, and Shell/Insert Adapters
2
Cleared 510(K)
K
20
0391
MPACT Extension
2
Cleared 510(K)
K
21
0893
Restoration Anatomic Shell
2
Cleared 510(K)
K
20
3557
EMPOWR Dual Mobility Metal Liner, EMPOWR Dual Mobility Poly Bearing
2
Cleared 510(K)
K
20
2472
ACTIS Duofix Hip Prosthesis
2
Cleared 510(K)
K
20
2484
Cordera Hip System
2
Cleared 510(K)
K
20
0854
DePuy PINNACLE Dual Mobility Liner
2
Cleared 510(K)
K
19
1708
Origin Stem, Evolve Stem, Aria Hip Stem, Remedy Stem, CoCr Femoral Head
2
Cleared 510(K)
K
20
0656
Delta Multihole TT Pro Acetabular System
2
Cleared 510(K)
K
19
3233
Restoration® Modular Hip System
2
Cleared 510(K)
K
19
1826
KeYi Total Hip System
2
Cleared 510(K)
K
19
2450
Precision Casting Solutions Total Hip System
2
Cleared 510(K)
K
19
0656
Dual Mobility - Longevity and Vivacit-E Polyethylene Hip Bearings
2
Cleared 510(K)
K
19
0660
G7 Acetabular System Longevity Highly Crosslinked Polyethylene, G7 Acetabular System Vivacit-E Vitamin E Highly Crosslinked Polyethylene
2
Cleared 510(K)
K
19
2919
Pinnacle Duofix HA Acetabular Cup Prosthesis
2
Cleared 510(K)
K
19
2198
Conformis Hip System
2
Cleared 510(K)
K
18
3457
Zimmer Biomet 12/14 CoCr Femoral Head and Freedom Head
2
Cleared 510(K)
K
19
1622
Delta Multihole TT Pro Acetabular System
2
Cleared 510(K)
K
19
1002
OR3O Dual Mobility System
2
Cleared 510(K)
K
19
0847
REDAPT Blade Augments
2
Cleared 510(K)
K
19
1358
Trident II Acetabular System
2
Cleared 510(K)
K
19
2071
iNSitu Total Hip System
2
Cleared 510(K)
K
19
0904
Conformis BeneFIT Hip System
2
Cleared 510(K)
K
19
1936
iNSitu Total Hip System
2
Cleared 510(K)
K
18
3129
Medtronic Total Hip Arthroplasty System
2
Cleared 510(K)
K
19
0123
MicroPort CoCr Femoral Heads
2
Cleared 510(K)
K
19
0057
DJO Acetabular System
2
Cleared 510(K)
K
18
2678
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology MR Labeling
2
Cleared 510(K)
K
18
2221
Bencox Mirabo Cup Multi Hole
2
Cleared 510(K)
K
18
3582
MPACT Extension
2
Cleared 510(K)
K
18
2468
Trident X3 Acetabular Inserts, ADM and MDM X3 Acetabular Inserts, Accolade II Hip System
2
Cleared 510(K)
K
18
2502
Alteon Acetabular Cup System
2
Cleared 510(K)
K
19
0276
Provident II Hip Stem
2
Cleared 510(K)
K
18
2099
Delta TT Pro
2
Cleared 510(K)
K
18
2109
REDAPT Modular Acetabular Shell
2
Cleared 510(K)
K
18
1366
REDAPT Porous Acetabular Shell
2
Cleared 510(K)
K
17
2857
Latitud Hip Replacement System
2
Cleared 510(K)
K
18
0798
Prime Acetabular Cup System
2
Cleared 510(K)
K
17
2551
Trinity PLUS Acetabular Shell
2
Cleared 510(K)
K
17
3951
Legend Acetabular Liners
2
Cleared 510(K)
K
17
1966
Mpact® 3D Metal™ Implants and Augments 3D Metal™
2
Cleared 510(K)
K
17
2456
Bone Screws 6.5mm
2
Cleared 510(K)
K
17
1934
Birmingham Hip (BH) Dual Mobility Insert
2
Cleared 510(K)
K
17
1073
Smith & Nephew, Inc. REDAPT Augments
2
Cleared 510(K)
K
17
2251
UTS Stem
2
Cleared 510(K)
K
17
2806
Bencox Mirabo Cup System
2
Cleared 510(K)
K
17
2684
Smith & Nephew, Inc. ANTHOLOGY™ AFIT Hip Stem
2
Cleared 510(K)
K
17
1768
Trident® II Acetabular System
2
Cleared 510(K)
K
17
2501
iNSitu Total Hip System
2
Cleared 510(K)
K
17
1962
Klassic HD® Hip System
2
Cleared 510(K)
K
16
2957
U2 Femoral Head
2
Cleared 510(K)
K
17
0444
PROCOTYL® PRIME Acetabular Cup System
2
Cleared 510(K)
K
16
2719
iTotal® Hip Replacement System
2
Cleared 510(K)
K
16
3193
UTF Stem, reduced, #0, #00
2
Cleared 510(K)
K
16
2127
Bencox M Stem Lateralized & Bencox Mirabo Cup System
2
Cleared 510(K)
K
16
1073
Klassic HD Hip System
2
Cleared 510(K)
K
16
1569
Trident® II Tritanium® Acetabular Shells and 6.5 mm Low Profile Hex Screws
2
Cleared 510(K)
K
16
1184
iNSitu Total Hip System
2
Cleared 510(K)
K
15
1424
The Progressive Orthopaedic Total Hip System
2
Cleared 510(K)
K
16
1190
G7 Dual Mobility System, Active Articulation System
2
Cleared 510(K)
K
15
3345
Stryker Orthopaedics Hip Systems Labeling Update
2
Cleared 510(K)
K
16
1080
Escalade Legend Acetabular Shell
2
Cleared 510(K)
K
15
2084
Bencox M Stem (Bencox Hip System) and Bencox ID Cemented Stem (with Centralizer) & Bencox Bone Plug
2
Cleared 510(K)
K
16
0266
ICONACY(TM) I-Hip(TM)
2
Cleared 510(K)
K
15
0790
REDAPT Porous Acetabular Shell and Cemented Liner
2
Cleared 510(K)
K
15
1603
Arcos One-piece Femoral Revision System
2
Cleared 510(K)
K
15
1440
Klassic HD Hip System
2
Cleared 510(K)
K
14
1960
Exactech® Novation® Crown Cup®
2
Cleared 510(K)
K
15
1448
Continuum and Trilogy Integrated Taper (IT) Acetabular Systems
2
Cleared 510(K)
K
15
1316
U2 Hip Stem, Ti Porous Coated, Matrix
2
Cleared 510(K)
K
15
1264
Restoration Anatomic Shell
2
Cleared 510(K)
K
15
0007
Modified Bencox Hip System
2
Cleared 510(K)
K
15
0522
G7 Dual Mobility System
2
Cleared 510(K)
K
15
0503
Echo Bi-Metric Microplasty Line Extension
2
Cleared 510(K)
K
14
3453
Mpact Double Mobility System
2
Cleared 510(K)
K
14
3314
Progressive Orthopaedic Total Hip System
2
Cleared 510(K)
K
14
2119
PROCOTYL L-O ACETABULAR SYSTEM
2
Cleared 510(K)
K
14
2882
G7 Freedom and Offset Liners, Freedom Head, Size 32
2
Cleared 510(K)
K
14
3085
Stryker Orthopaedics Acetabular Shells, Femoral Stems and Total Hip Instruments for use with the Direct Superior Approach
2
Cleared 510(K)
K
14
2606
Trident® Tritanium® PST® Acetabular Shells
2
Cleared 510(K)
K
14
2201
OMNI Interface Acetabular System
2
Cleared 510(K)
K
14
0547
EXCERA FITRITE TOTAL HIP ARTHROPLASTY SYSTEM
2
Cleared 510(K)
K
14
2746
G7 Finned Acetabular Shell
2
Cleared 510(K)
K
14
3009
Echo Bi-Metric Microplasty Hip System
2
Cleared 510(K)
K
14
0669
G7 OSSEOTI ACETUBLAR SHELLS
2
Cleared 510(K)
K
14
2462
Restoration Anatomic Shell
2
Cleared 510(K)
K
14
1676
RENOVIS SURGICAL POROUS ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
14
1001
ALPINE HIP STEM; ALPINE HA HIP STEM
2
Cleared 510(K)
K
14
1797
ALTEON 6.5MM BONE SCREWS
2
Cleared 510(K)
K
13
3370
REMEDY HIP STEM, PEGASUS HIP STEM, EVOLVE HELIOS HIP STEM, EVOLVE MASTERS HIP STEM, EVOLVE DISTAL CENTRALIZER, EVOLVE CE
2
Cleared 510(K)
K
14
1395
DELTA TT ACETABULAR SYSTEM
2
Cleared 510(K)
K
13
2697
ENCOMPASS 10/12 HIP STEM
2
Cleared 510(K)
K
14
1043
CS2 MULTI-HOLE ACETABULAR SHELL
2
Cleared 510(K)
K
13
2312
RENOVIS TESERA TRABECULAR TECHNOLOGY (T3) ACETABULAR SHELL SYSTEM
2
Cleared 510(K)
K
13
2572
I-HIP TOTAL HIP SYSTEM
2
Cleared 510(K)
K
13
3832
KLASSIC HD HIP SYSTEM, OFFSET FEMORAL STEM, NON-POROUS / POROUS
2
Cleared 510(K)
K
13
3386
OVATION TRIBUTE HIP STEM; OVATION NARROW HIP STEM
2
Cleared 510(K)
K
13
2959
DEPUY PINNACLE ALTRX ACETABULAR LINERS
2
Cleared 510(K)
K
13
2158
NOVOHIP TOTAL HIP SYSTEM
2
Cleared 510(K)
K
13
1454
KLASSIC HD(TM) EXTENDED OFFSET FEMORAL HEAD
2
Cleared 510(K)
K
13
2879
MPACT EXTENSION
2
Cleared 510(K)
K
13
3228
ICONACY I-HIP SYSTEM, GRADUAL TRANSITIONING (GT) FEMORAL SYSTEM
2
Cleared 510(K)
K
13
1022
OVATION 10/12 HIP STEM
2
Cleared 510(K)
K
13
2626
PIPELINE TOTAL HIP SYSTEM (LINE EXTENSION)
2
Cleared 510(K)
K
13
2207
UTF STEM-REDUCED, ADDITIONAL SIZES
2
Cleared 510(K)
K
13
1279
ICONACY I-HIP SYSTEM
2
Cleared 510(K)
K
13
0353
PIPELINE TOTAL HIP SYSTEM (LINE EXTENSION)
2
Cleared 510(K)
K
13
0099
TAPERFILL FEMORAL HIP STEM 425-31-005_017 425-41-005_019
2
Cleared 510(K)
K
13
1237
PIPELINE TOTAL HIP SYSTEM
2
Cleared 510(K)
K
13
0149
U2 HIP SYSTEM, EXPANDED INDICATIONS FOR USE
2
Cleared 510(K)
K
12
3550
UTF STEM, REDUCED
2
Cleared 510(K)
K
12
0599
DEPUY M-SPEC 36MM FEMORAL HEADS
2
Cleared 510(K)
K
13
0063
ARCOS TROCHANTER BUTTON
2
Cleared 510(K)
K
12
1297
ORIGIN HIP STEM, FEMORAL HEAD, LOGICAL PX-SERIES ACETABULAR SHELL, LOCIGAL G-SERIES ACETABULAR SHELL, LOGICAL ACETABULAR
2
Cleared 510(K)
K
11
2898
DELTA TT CUPS, DELTA TT LINERS, BONE SCREWS
2
Cleared 510(K)
K
12
2512
CS2 HIP SYSTEM
2
Cleared 510(K)
K
12
2636
REVELATION POROUS COATED HIP STEM, SIZE 8
2
Cleared 510(K)
K
12
3012
SMITH & NEPHEW SMF HIP STEM
2
Cleared 510(K)
K
12
1636
ZENITH, FEMORAL STEM ZENITH, DISTAL CENTRALIZER FOMORAL HEAD ACETABULAR INSERT
2
Cleared 510(K)
K
12
3019
LONGEVITY IT HIGHLY CROSSLINKED POLYETHYENE LINERS
2
Cleared 510(K)
K
12
2798
INTEGRIP ACETABULAR SHELL, INTEGRIP REVISION ACETABULAR SHELL
2
Cleared 510(K)
K
12
2504
FEMORAL HEADS, 2.5 AND 7.5 MM NECK LENGTH
2
Cleared 510(K)
K
12
2099
BENCOX II STEM, BENCOX METAL HEAD
2
Cleared 510(K)
K
12
1684
NOVATION LPI PRIME FEMORAL STEM
2
Cleared 510(K)
K
11
3296
ZMR HIP SYSTEM KWZ-PROSTHESIS, HIP, CONSTRAINED, CEMENTED OR UNCEMENTED, METAL/POLYMER
2
Cleared 510(K)
K
12
1935
TAPERSET HIP SMALL STEMS
2
Cleared 510(K)
K
12
0924
BENCOX MIRABO CUP BENCOX MIRABO INSERT (STANDARD& ELEVATED TYES) BENCOX MIRABO CUP SCREW HOLE PLUG
2
Cleared 510(K)
K
12
1034
IOI TOTAL HIP
2
Cleared 510(K)
K
12
2244
POLARCUP DUAL MOBILITY SYSTEM
2
Cleared 510(K)
K
12
0030
TAPERLOC COMPLETE SIZE 4MM AND XR 123
2
Cleared 510(K)
K
12
1308
HIP SYSTEMS
2
Cleared 510(K)
K
12
1777
U2 ACETABULAR CUP, PLASMA SPRAY
2
Cleared 510(K)
K
12
1024
LINEAR POROUS COATED HIP STEM, SIZE 5; REVELATION HIP STEM, SIZE 8; FOUNDATION POROUS PRESS FIT STEM, SIZE 8;
2
Cleared 510(K)
K
12
1263
TAPER SET HIP SYSTEM RDP STEM
2
Cleared 510(K)
K
11
2158
MODULUS STEMS, MODULUS NECKS, MODULAR FEMORAL HEADS, CEMENTED CUPS, LOCK BIPOLAR HEADS
2
Cleared 510(K)
K
12
0241
LINEAR HIP STEM, SIZE 5
2
Cleared 510(K)
K
11
3242
APEX ARC HIP STEM
2
Cleared 510(K)
K
11
3609
NOVATION INTEGRIP ACETABULAR AUGMENTS, GROUPS 4 AND 5
2
Cleared 510(K)
K
11
2779
APEX MODULAR ACCTABULAR CUP (NOW NAMED APEX INTERFACE ACETABULAR SYSTEM)
2
Cleared 510(K)
K
11
0135
POLARCUP DUAL MOBILITY SYSTEM
2
Cleared 510(K)
K
11
1472
HELICON HIP SYSTEM, FEMORAL STEM, HELICON HIP SYSTEM, FEMORAL HEAD, COCR, HELICON HIP SYSTEM, ACETABULAR SHELL, HELICON
2
Cleared 510(K)
K
11
0245
UNITED UTF STEM
2
Cleared 510(K)
K
10
3431
COREN TOTAL HIP SYSTEM
2
Cleared 510(K)
K
11
1546
U2 HIP SYSTEM
2
Cleared 510(K)
K
11
0947
APEX K1 HIP STEM
2
Cleared 510(K)
K
10
3662
CONTINUUM AND TRILOGY INTEGRATED TAPER (IT) ACETABULAR SYSTEMS; LONGEVITY IT HIGHLY CROSSLINKED POLYETHYLENE ELEVATED LI
2
Cleared 510(K)
K
10
1072
TRITANIUM PERI-APATITIE ACETABULAR SOLID-BACKED SHELL, TRITANIUM PERI-APATITE
2
Cleared 510(K)
K
11
0542
CONSENSUS BIOLOX DELTA CERAMIC FEMORAL HEAD
2
Cleared 510(K)
K
11
0555
ARCOMXL ACTIVE ARTICULATION
2
Cleared 510(K)
K
10
3721
MPACT ACETABULAR SYSTEM
2
Cleared 510(K)
K
10
3384
ESCALADE ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
10
2019
RESTORATION ACETABULAR WEDGE AUGMENTS
2
Cleared 510(K)
K
10
3256
SMITH & NEPHEW SMF HIP STEM
2
Cleared 510(K)
K
10
1336
E1 AVANTAGE HEAD
2
Cleared 510(K)
K
10
1229
LONGEVITY IT HIGHLY CROSSLINKED POLYETHYLENE ELEVATED LINERS, CONTINUUM ACETABULAR SYSTEM AND TRILOGY INTEGRATED TAPER
2
Cleared 510(K)
K
10
0445
KLASSIC HD HIP SYSTEM
2
Cleared 510(K)
K
10
2399
CONSENSUS TAPERSET HIP SYSTEM
2
Cleared 510(K)
K
10
3124
SERIES II X3 LARGE DIAMETER ACCETABULAR INSERTS
2
Cleared 510(K)
K
10
2975
NOVATION CROWN CUP WITH INTEGRIP ACETABULAR SHELL, CLUSTER-HOLE
2
Cleared 510(K)
K
10
2423
DEPUY PINNACLE ALTRX ACETABULAR LINERS
2
Cleared 510(K)
K
10
0933
CONSENSUS CS2 PLUS ACETABULAR INSERT
2
Cleared 510(K)
K
10
1761
EXACTECH NOVATION EMPIRE ACETABULAR AUGMENT WITH INTEGRIP MODEL 186-01-08/11/13, 186-02-08/11/13, 186-03-08/11/13
2
Cleared 510(K)
K
10
1976
INTERFACE ACETABULAR SYSTEM, ACETABULAR INSERT +4 OFFSET
2
Cleared 510(K)
K
10
1575
APEX MODULAR HEAD, SIZE 28 ,32, 26 AND 40 MM+10.5 OFFSET, MODELS 302810, 303210,303610,304010
2
Cleared 510(K)
K
10
0269
NOVATION CROWN CUP GXL LINERS
2
Cleared 510(K)
K
09
3561
ZIMMER TRABECULAR METAL MODULAR ACETABULAR SYSTEM
2
Cleared 510(K)
K
09
4045
MODIFICAITON TO: CARDO MEDICAL HIP SYSTEM
2
Cleared 510(K)
K
10
0555
APEX-LNK ACETABULAR INSERT, E, APEX-LNK ACETABULAR INSERT, F, APEX-LNK
2
Cleared 510(K)
K
09
2098
PATIENT SPECIFIC ACETABULAR RECONSTRUCTION PROSTHESIS
2
Cleared 510(K)
K
09
2443
INTERFACE ACETABULAR CUP LINERS
2
Cleared 510(K)
K
09
0897
TRITANIUM NON-MODULAR SHELL & X3 ALL-POLY INSERT
2
Cleared 510(K)
K
09
1508
ZIMMER CONTINUUM ACETABULAR SYSTEM, ZIMMER TRILOGY IT ACETABULAR SYSTEM
2
Cleared 510(K)
K
08
1566
SMITH & NEPHEW OXINIUM DH FEMORAL HEADS
2
Cleared 510(K)
K
08
1679
REVELATION HIP STEM, MODELS, 427-01, 427-02; LINEAR HIP STEM, MODELS 425-00, 425-05
2
Cleared 510(K)
K
08
1171
TRITANIUM ACETABULAR SHELL SYSTEM
2
Cleared 510(K)
K
07
2817
ECHELON TITANIUM HIP SYSTEM
2
Cleared 510(K)
K
08
0625
SMITH & NEPHEW MIS HIP STEM WITH STIKTITE
2
Cleared 510(K)
K
07
3150
APEX-LNK POLY ACETABULAR CUP LINERS
2
Cleared 510(K)
K
07
3068
ACCIN HIP SYSTEM
2
Cleared 510(K)
K
07
2888
REVELATION AND LINEAR HIP STEMS AND FMP ACETABULAR SHELLS (SPIKED, HEMISPHERICAL AND FLARED)
2
Cleared 510(K)
K
07
2417
SMITH & NEPHEW MIS HIP STEM
2
Cleared 510(K)
K
07
2963
DEPUY PINNACLE ALTRX ACETABULAR LINERS
2
Cleared 510(K)
K
07
2154
FOUNDATION (FMP) POROUS COATED SPIKED ACETABULAR SYSTEM
2
Cleared 510(K)
K
07
2101
RIGI-FIX HIP STEM SYSTEM
2
Cleared 510(K)
K
07
1160
REFLECTION, TANDEM UNIPOLAR
2
Cleared 510(K)
K
06
2489
APEX HCLA ACETABULAR CUP LINERS
2
Cleared 510(K)
K
07
1784
DEPUY PINNACLE WITH GRIPTON ACETABULAR CUPS
2
Cleared 510(K)
K
07
0050
VITALITY HIP SYSTEM MODEL#420
2
Cleared 510(K)
K
07
0278
POLARCUP DUAL MOBILITY SYSTEM
2
Cleared 510(K)
K
07
0369
REGENERX RINGLOC + MODULAR ACETABULAR SHELLS
2
Cleared 510(K)
K
06
3822
MODIFICATION TO HIPSTAR FEMORAL STEM
2
Cleared 510(K)
K
06
2775
EUROPEAN STYLE TAPER,PRESS-FIT HIP STEM
2
Cleared 510(K)
K
06
1461
MAYO CONSERVATIVE HIP PROSTHESIS, MODEL 00.65-8026-010-05
2
Cleared 510(K)
K
06
3257
FMP COATED SPIKED ACETABULAR CUP; HEMISPHERICAL ACETABULAR CUP; FLARED RIM ACETABULAR CUP; METAL/METAL ACETABULAR INSERT
2
Cleared 510(K)
K
06
2419
TRIDENT LARGE DIAMETER ACETABULAR INSERTS
2
Cleared 510(K)
K
06
2148
DEPUY PINNACLE ALTRX ACETABULAR CUP LINER
2
Cleared 510(K)
K
06
0072
MONOBLOCK PRESS-FIT HIP STEM
2
Cleared 510(K)
K
06
1434
TRIDENT LARGE DIAMETER HIP SYSTEM
2
Cleared 510(K)
K
06
1226
TRABECULAR METAL ACETABULAR REVISION SYSTEM CAGE
2
Cleared 510(K)
K
06
1786
VERSYS FIBER METAL MIDCOAT LOW HEAD CENTER HIP PROSTHESIS
2
Cleared 510(K)
K
05
3417
M-COR HIP REPLACEMENT SYSTEM
2
Cleared 510(K)
K
06
1168
PCA 36MM FEMORAL HEADS
2
Cleared 510(K)
K
06
1124
ORTHOPEDIC SOURCE PRESS-FIT HIP
2
Cleared 510(K)
K
06
1833
DEPUY AML HIP PROSTHESIS
2
Cleared 510(K)
K
06
1547
DYNASTY ACETABULAR SHELL; DYNASTY A-CLASS POLY ACETABULAR LINER
2
Cleared 510(K)
K
06
0630
REFLECTION 3-HOLE SHELL WITH ASYMMETRIC POROUS COATING
2
Cleared 510(K)
K
06
1067
TRABECULAR METAL ACETABULAR AUGMENTS
2
Cleared 510(K)
K
06
0581
DEPUY SOLUTION SYSTEM HIP PROSTHESIS
2
Cleared 510(K)
K
06
0040
ZIMMER M/L TAPER HIP PROSTHESIS
2
Cleared 510(K)
K
06
0635
CONSENSUS ACETABULAR SHELL SYSTEM
2
Cleared 510(K)
K
05
2996
POROUS TITANIUM ACETABULAR SHELLS
2
Cleared 510(K)
K
05
2089
XR-SERIES BI-METRIC FEMORAL COMPONENTS
2
Cleared 510(K)
K
05
3293
ENCOMPASS 10*17 AND 12*17 EXTENDED PRESS-FIT HIP STEMS
2
Cleared 510(K)
K
05
2321
VERSYS EPOCH FULLCOAT HIP PROSTHESIS
2
Cleared 510(K)
K
06
0031
DEPUY MODULAR M HEADS
2
Cleared 510(K)
K
05
3557
ESKA-LIBUR HIP STEM
2
Cleared 510(K)
K
05
2026
LINEAGE A-CLASS POLY LINER
2
Cleared 510(K)
K
05
2255
ARCOMXL POLYETHYLENE RX90 ACETABULAR LINERS
2
Cleared 510(K)
K
05
0327
E-POLY (VITAMIN E) ACETABULAR LINERS
2
Cleared 510(K)
K
05
1556
ACUMATCH A-SERIES CONNEXION GXL ENHANCED CROSSLINKED POLYTHYLENE
2
Cleared 510(K)
K
05
1491
TRABECULAR METAL PRIMARY HIP PROSTHESIS
2
Cleared 510(K)
K
05
0937
TRABECULAR METAL ACETABULAR REVISION SHELLS
2
Cleared 510(K)
K
04
2989
RX90 LOW PROFILE ACETABULAR SYSTEM
2
Cleared 510(K)
K
04
2565
ENCOMPASS HIP STEM, TRI-PLUS ACETABULAR SHELL, TRI-PLUS DCM LINER
2
Cleared 510(K)
K
04
2051
ARCOMXL POLYETHYLENE LINERS
2
Cleared 510(K)
K
04
3123
APEX MODULAR HA HIP STEM
2
Cleared 510(K)
K
03
3716
TRIDENT ACETABULAR SYSTEM
2
Cleared 510(K)
K
04
2774
MALLORY-HEAD MODULAR CALCAR STEMS WITH INTERLOCKING SLOTS
2
Cleared 510(K)
K
04
3537
TAPERLOC 12/14 TAPER FEMORAL COMPONENTS
2
Cleared 510(K)
K
04
2871
TRABECULAR METAL ACETABULAR AUGMENTS, MODELS 4894-XXX-YY, 02-212-105XX3, 02-212-205XX3, 02-212-305XX3
2
Cleared 510(K)
K
04
1950
APEX K2 HIP SYSTEM
2
Cleared 510(K)
K
04
1850
MEDALLION MODULAR HIP SYSTEM
2
Cleared 510(K)
K
04
2252
NEXFLEX TOTAL HIP SYSTEM
2
Cleared 510(K)
K
03
1402
PERFECTA FEMORAL STEM
2
Cleared 510(K)
K
04
2029
X-SERIES INTEGRAL RPP FEMORAL COMPONENTS
2
Cleared 510(K)
K
04
2776
VERSYS HIP SYSTEM BEADED MIDCOAT LOW HEAD CENTER HIP PROSTHESIS, MODEL 00-7840-XXX-XX
2
Cleared 510(K)
K
04
2337
ZIMMER M/L TAPER HIP PROSTHESIS WITH CALCICOAT CERAMIC COATING
2
Cleared 510(K)
K
04
1906
EXACTECH 12/14 TOTAL HIP SYSTEM
2
Cleared 510(K)
K
04
0191
BICONTACT HIP STEM AND FEMORAL HEAD
2
Cleared 510(K)
K
03
3580
NEXFLEX TOTAL HIP SYSTEM
2
Cleared 510(K)
K
04
1109
ZIMMER ANATOMIC II HIP PROSTHESIS
2
Cleared 510(K)
K
04
0544
DURALOC OPTION ACETABULAR CUP SYSTEM, MODELS 1599-01-044 TO -066, 1599-11-044 TO -062 AND 1599-21-044 TO -062
2
Cleared 510(K)
K
04
0412
TRIDENT T ACETABULAR SHELLS
2
Cleared 510(K)
K
04
0383
TRIFLANGE II ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
03
3273
DEPUY PINNACLE ACETABULAR CUP SYSTEM, ESL MARATHON POLYETHYLENE LINERS, AND DEPUY ULTIMA UNIPOLAR FEMORAL HEADS
2
Cleared 510(K)
K
03
3893
SPECTRUM MODULAR SYSTEM
2
Cleared 510(K)
K
03
3338
PINNACLE REVISION SYSTEM
2
Cleared 510(K)
K
03
2729
Z-SERIES MODULAR TOTAL HIP SYSTEM
2
Cleared 510(K)
K
03
2964
EXACTECH 12/14 ALUMINA FEMORAL HEAD; EXACTECH ACUMATCH M-SERIES 12/14 NECK SEGMENTS
2
Cleared 510(K)
K
03
3034
VERSYS BEADED FULLCOAT CALCAR HIP PROSTHESIS
2
Cleared 510(K)
K
03
2385
GLOBAL PRESS-FIT STEM
2
Cleared 510(K)
K
03
2726
ZIMMER M/L TAPER HIP PROSTHESIS, 7711 SERIES
2
Cleared 510(K)
K
03
2581
GLOBAL MODULAR REPLACEMENT SYSTEM ANTEVERTED PROMIMAL FEMORAL COMPONENT
2
Cleared 510(K)
K
03
0055
MALLORY/HEAD TOTAL HIP SYSTEM; HA MALLORY/HEAD TOTAL HIP SYSTEM; BI-METRIC FEMORAL COMPONENTS
2
Cleared 510(K)
K
03
1693
MALLORY/HEAD MODULAR CALCAR WITH AND WITHOUT HA
2
Cleared 510(K)
K
03
1572
ZMR HIP SYSTEM-XL, MODELS 9921, 9922 AND 9923
2
Cleared 510(K)
K
03
0861
HA PMI FLANGED ACETABULAR COMPONENT
2
Cleared 510(K)
K
03
1495
PINNACLE DUOFIX HA ACETABULAR CUP PROSTHESIS
2
Cleared 510(K)
K
03
1110
APEX MODULAR ACETABULAR CUP
2
Cleared 510(K)
K
03
0733
MAYO CONSERVATIVE HIP PROSTHESIS, MODEL 8026 SERIES
2
Cleared 510(K)
K
03
0979
MODIFICATION TO DEPUY SOLUTION SYSTEM HIP PROSTHESIS
2
Cleared 510(K)
K
03
0501
X-SERIES INTEGRAL LATERALIZED HIP COMPONENTS
2
Cleared 510(K)
K
02
1878
ESKA MODULAR HIP SYSTEM ACETABULAR COMPONENTS
2
Cleared 510(K)
K
02
2520
U2 ACETABULAR CUP
2
Cleared 510(K)
K
03
0236
ACUMATCH P-SERIES POROUS PRESS-FIT FEMORAL COMPONENT
2
Cleared 510(K)
K
03
0079
VERSYS BEADED FULLCOAT BOWED REVISION HIP PROSTHESIS
2
Cleared 510(K)
K
03
0048
HA PMI FEMORAL HIP STEM
2
Cleared 510(K)
K
02
3409
HA X-SERIES BI-METRIC HIP FEMORAL COMPONENTS
2
Cleared 510(K)
K
02
3357
ARCPM 1050 RESIN-HIPS
2
Cleared 510(K)
K
02
3375
MODIFICATION TO ESOP CO-CR FEMORAL HEADS
2
Cleared 510(K)
K
02
2382
RHS ACETABULAR COMPONENT
2
Cleared 510(K)
K
02
2902
SMITH & NEPHEW HIP SYSTEM
2
Cleared 510(K)
K
02
1891
ZIMMER TRABECULAR METAL MODULAR ACETABULAR SYSTEM
2
Cleared 510(K)
K
02
2556
REFLECTION MODIFIED ACETABULAR SHELLS
2
Cleared 510(K)
K
02
2711
MODIFICATION TO AVALON CUP SYSTEM
2
Cleared 510(K)
K
02
2463
HA MODULAR REACH PROXIMAL POROUS AND HA MODULAR REACH COLLARED PROXIMAL POROUS FEMORAL STEMS
2
Cleared 510(K)
K
01
4070
EPOCH HIP PROSTHESIS, MODEL 4075 SERIES
2
Cleared 510(K)
K
02
1466
CONSENSUS ACETABULAR INSERT, CROSS-LINKED POLYETHYLENE
2
Cleared 510(K)
K
02
1970
THE TRABECULAR METAL MONOBLOCK CUP, MODELS 00-7259-0XX-28 (ZIMMER CAT. #) AND 02-293-28XX1 (IMPLEX PART #)
2
Cleared 510(K)
K
02
1911
TRIDENT CROSSFIRE POLYUETHYLENE LINERS
2
Cleared 510(K)
K
02
1346
STEM HIP REPLACEMENT SYSTEM, MODEL PHA002XX
2
Cleared 510(K)
K
02
1109
ESOP CO-CR FEMORAL HEADS
2
Cleared 510(K)
K
02
0145
ORTHOPAEDIC INNOVATIONS RENEWAL ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
02
0153
CONSENSUS ACETABLAR SHELL, TI COATED
2
Cleared 510(K)
K
02
0580
X-SERIES BI-METRIC HIP FEMORAL COMPONENTS
2
Cleared 510(K)
K
01
2787
VAPORIZED HYDROGEN PEROXIDE (VHP) STERILIZATION OF UHMWPE COMPONENTS IN THE REFLECTION ACTABULAR SYSTEM (ACETABULAR LINE
2
Cleared 510(K)
K
02
0497
TRIDENT ELEVATED RIM LINER
2
Cleared 510(K)
K
02
0170
KEYSTONE HIP SYSTEM CALCAR REPLACEMENT BODY AND BUILD UP
2
Cleared 510(K)
K
01
3490
CEMENTED CALCAR HIP SYSTEM
2
Cleared 510(K)
K
01
3475
TRIDENT POROUS TITANIUM ACETABULAR COMPONENT WITH PERI-APATITE COATING
2
Cleared 510(K)
K
01
3658
MODIFICATION TO REFLECTION CROSS-LINKED UHMWPE ACETABULAR COMPONENTS
2
Cleared 510(K)
K
01
2739
CONVERGE ACETABULAR SYSTEM
2
Cleared 510(K)
K
01
2364
AML HIP PROSTHESIS
2
Cleared 510(K)
K
01
2507
THE TRABECULAR METAL TECHNOLOGY ACETABULAR AUGMENT SYSTEM, MODELS 4893-XX-YY (ZIMMER), 02-212-05XX1 ( IMPLEX)
2
Cleared 510(K)
K
01
1489
SUMMIT DUOFIX HIP PROSTHESIS
2
Cleared 510(K)
K
01
1081
ACUMATCH M-SERIES EXTRA-SMALL METAPHYSEAL SEGMENTS
2
Cleared 510(K)
K
01
0170
TRIDENT POROUS TITANIUM ACETABULAR COMPONENT
2
Cleared 510(K)
K
01
0171
DURALOC ACETABULAR CUP SYSTEM, 36MM MARATHON +4 POLYETHYLENE LINER
2
Cleared 510(K)
K
01
0367
MODIFICATION TO TITANIUM TRI-LOCK HIPS STEM
2
Cleared 510(K)
K
00
3875
TI-REPLICA HIP STEM
2
Cleared 510(K)
K
00
4032
PERFECTA AND EXTEND
2
Cleared 510(K)
K
01
0282
LATERAL OFFSET PROTRACT PRESS FIT HIP STEM
2
Cleared 510(K)
K
01
0120
MODIFICATION TO EXACTECH ACUMATCH INTEGRATED HIP SYSTEM, M-SERIES HIGH OFF-SET NECK SEGMENT, M-SERIES LOW OFF-SET NECK S
2
Cleared 510(K)
K
00
3800
AML HIP PROSTHESIS
2
Cleared 510(K)
K
01
0241
PROTRACT PRESS FIT HIP STEM-HA COATED
2
Cleared 510(K)
K
00
3478
TRIOLOGY ACETABULAR SYSTEM 46MM LARGE HEAD LINERS, MODEL 6310
2
Cleared 510(K)
K
00
3237
U2 HIP STEM, TI POROUS COATED
2
Cleared 510(K)
K
00
3199
TRIAD II MODULAR TOTAL HIP SYSTEM
2
Cleared 510(K)
K
00
3447
PROTRACT PRESS FIT HIP STEM
2
Cleared 510(K)
K
00
2747
REFLECTION CROSS-LINKED UHMWPE ACETABULAR COMPONENTS
2
Cleared 510(K)
K
00
2960
TRILOGY ACETABULAR SYSTEM LARGE HEAD LINER, MODEL 6353
2
Cleared 510(K)
K
99
4078
U1 HIP SYSTEM
2
Cleared 510(K)
K
00
3429
MALLOY/HEAD LATERALIZED PRESS-FIT FEMORAL
2
Cleared 510(K)
K
00
3181
IMPLEX CONTINUUM HIP SYSTEM ACETABULAR COMPONENTS - MODEL XX-YYY-ZZZZ
2
Cleared 510(K)
K
00
2149
LINEAGE ACETABULAR SYSTEM
2
Cleared 510(K)
K
00
1991
TITAN POROCOAT HIP PROSTHESIS
2
Cleared 510(K)
K
00
0788
APEX MODULAR HIP STEM
2
Cleared 510(K)
K
00
1982
TRI-LOCK HIP STEM
2
Cleared 510(K)
K
00
1778
POROCOAT PRODIGY HIP PROSTHESIS
2
Cleared 510(K)
K
00
1320
SULZER ORTHOPEDICS INC. NATURAL-HIP SYSTEM LD STEM
2
Cleared 510(K)
K
00
1277
TRIFLANGE ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
00
1039
THE IMPLEX HEDROCEL MODULAR ELLIPTICAL ACETABULAR CUP
2
Cleared 510(K)
K
00
1660
MALLORY HEAD MODULAR CALCAR
2
Cleared 510(K)
K
00
1534
PINNACLE ACETABULAR SYSTEM
2
Cleared 510(K)
K
00
0760
REACH FEMORAL COMPONENT
2
Cleared 510(K)
K
00
0521
KEYSTONE HIP
2
Cleared 510(K)
K
99
0830
MALLORY/HEAD CALCAR REPLACEMENT WITH INTERLOCKING SLOTS BI-METRIC POROUS COLLARED STEM WITH INTERLOCKING SLOTS
2
Cleared 510(K)
K
00
0321
HEMISPHERE MODULAR CUP SYSTEM
2
Cleared 510(K)
K
99
3027
ESKA MODULAR HIP SYSTEM
2
Cleared 510(K)
K
99
2154
BICON-PLUS ACETABULAR COMPONENTS
2
Cleared 510(K)
K
00
0306
PINNACLE ACETABULAR SYSTEM
2
Cleared 510(K)
K
00
0538
MALLORY/HEAD LATERALIZED PRESS-FIT FEMORAL
2
Cleared 510(K)
K
99
4286
ZMR HIP SYSTEM-POROUS REVISION
2
Cleared 510(K)
K
99
3259
INTER-OP DURASUL ACETABULAR INSERTS/COCR FEMORAL HEADS
2
Cleared 510(K)
K
00
0335
MALLORY-HEAD MODULAR CALCAR TOTAL HIP SYSTEM
2
Cleared 510(K)
K
00
0334
IMPACT MODULAR TOTAL HIP SYSTEM
2
Cleared 510(K)
K
00
0207
POROCOAT PRODIGY HIP PROSTHESIS
2
Cleared 510(K)
K
99
4415
MARATHON CROSS-LINKED POLYETHYLENE ACETABULAR CUP LINERS
2
Cleared 510(K)
K
99
4070
REVELATION POROUS HIP STEM
2
Cleared 510(K)
K
99
3736
EXACTECH ACUMATCH INTEGRATED HIP SYSTEM M-SERIES FEMORAL STEM COMPONENT
2
Cleared 510(K)
K
99
4038
MODULAR REACH HIP
2
Cleared 510(K)
K
99
0849
DURATION IV STERILIZATION PROCESS (ACETABULAR INSERTS)
2
Cleared 510(K)
K
99
3352
CROSSFIRE SYSTEM 12 ACETABULAR INSERTS
2
Cleared 510(K)
K
99
3082
EXACTECH ACUMATCH INTEGRATED HIP SYSTEM A-SERIES POROUS COATED ACETABULAR COMPONENT
2
Cleared 510(K)
K
99
2667
ZMR HIP SYSTEM-REVISION TAPER
2
Cleared 510(K)
K
99
1026
REFLECTION CROSSLINKED UHMWPE ACETABULAR COMPONENTS
2
Cleared 510(K)
K
99
2109
ENCORE FULLY COATED HIP
2
Cleared 510(K)
K
99
1485
SYNERGY POROUS SIZE 8 HIP STEM
2
Cleared 510(K)
K
99
0135
TRILOGY ACETABULAR SYSTEM LONGEVITY CROSSLINKED POLYETHYLENE
2
Cleared 510(K)
K
99
1807
TITANIUM LOW PROFILE SCREWS
2
Cleared 510(K)
K
98
3837
HEDROCEL ACETABULAR CAGE SYSTEM
2
Cleared 510(K)
K
99
1325
MODIFICATION OF ENCORE LINEAR POROUS COATED HIP
2
Cleared 510(K)
K
99
1123
PERFECTA RS LATERALIZED HIP STEM, BRIDGE HIP SYSTEM
2
Cleared 510(K)
K
99
0523
B2C, ESPACE REVISION CUP SYSTEM
2
Cleared 510(K)
K
98
4492
TIGRAN HIP PROSTHESIS
2
Cleared 510(K)
K
99
0003
J-SERIES OMEGA TOTAL HIP SYSTEM
2
Cleared 510(K)
K
98
3834
ECHELON HIP STEM
2
Cleared 510(K)
K
98
4296
LATERALIZED INTERGRAL POROUS PRIMARY FEMORAL COMPONENT
2
Cleared 510(K)
K
98
4408
130 MODIFIED INTEGRAL FEMORAL COMPONENT
2
Cleared 510(K)
K
98
3509
INTER-OP ACETABULAR SYSTEM - DURASUL ACETABULAR INSERT
2
Cleared 510(K)
K
98
4459
DEPUY PROFILE FEMORAL HIP WITH POROCOAT
2
Cleared 510(K)
K
98
3502
OSTEONICS SECUR-FIT AD GENERATION II ACETABULAR COMPONENT SYSTEM
2
Cleared 510(K)
K
98
3491
DEPUY DURALOC ACETABULAR CUP SYSTEM-ENDURON LINER
2
Cleared 510(K)
K
98
3035
CUSTOM FLANGED ACETABULAR COMPONENT
2
Cleared 510(K)
K
98
0711
HARRIS/GALANTE POROUS (HGP) HIP PROSTHESIS WITH CALCICOAT CERAMIC COATING
2
Cleared 510(K)
K
98
3014
SUMMIT ACETABULAR SYSTEM
2
Cleared 510(K)
K
98
2248
HOWMEDICA ASYMMETRIC STEM VITALOCK CLUSTER & SPIKED SHELLS, AND ACETABULAR SHELLS WITH MESH INGROWTH SURFACE WITH PERI-A
2
Cleared 510(K)
K
98
2367
REACH HIP COMPONENT
2
Cleared 510(K)
K
98
1211
APR -T REVISION HIP STEM
2
Cleared 510(K)
K
98
0981
OMEGA HA COATED TOTAL HIP SYSTEM
2
Cleared 510(K)
K
98
0020
ACTIVELOCK MODULAR FEMORAL HIP SYSTEM
2
Cleared 510(K)
K
97
4740
DEPUY TRI-LOCK HIP STEM
2
Cleared 510(K)
K
97
4506
LSF HA COATED TRIAD TOTAL HIP SYSTEM
2
Cleared 510(K)
K
97
1206
MERIDIAN ST FEMORAL STEM AND VITALOCK SOLID BACK SHELL W/ PERI-APATITE COATING
2
Cleared 510(K)
K
97
4331
UNI-ROM TOTAL HIP SYSTEM FEMORAL STEM
2
Cleared 510(K)
K
97
4093
FOUNDATION POROUS COATED HEMISPHERICAL SHELL
2
Cleared 510(K)
K
97
4095
FOUNDATION POROUS COATED FLARED RIM SHELL
2
Cleared 510(K)
K
97
3119
FOUNDATION POROUS ACETABULAR SYSTEM
2
Cleared 510(K)
K
97
4294
ENCORE LINEAR POROUS COATED HIP
2
Cleared 510(K)
K
97
3714
VERSYS HIP SYSTEM BEADED HIP PROSTHESIS
2
Cleared 510(K)
K
97
3685
REVELATION POROUS HIP STEM
2
Cleared 510(K)
K
97
3675
NATURAL-HIP POROUS STEM WITH OFFSET
2
Cleared 510(K)
K
97
1824
REACH FEMORAL HIP COMPONENT
2
Cleared 510(K)
K
97
3302
FOUNDATION POROUS HIP STEM
2
Cleared 510(K)
K
97
3163
ACETABULAR SHELLS WITH MESH INGROWTH SURFACE
2
Cleared 510(K)
K
97
2596
DEPUY DURALOC ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
97
3124
APR POROUS HA HIP SYSTEM
2
Cleared 510(K)
K
97
1018
SMC ACETABULAR COMPONENT
2
Cleared 510(K)
K
97
3530
INFINTY DISTAL FEMORAL COMPONENT
2
Cleared 510(K)
K
97
2393
INTER-OP HA POROUS ACETABULAR SYSTEM (HA/CSTI)
2
Cleared 510(K)
K
97
0241
DEPUY PROXIMAL FEMORAL REPLACEMENT PROSTHESIS
2
Cleared 510(K)
K
96
4616
QUATROLOC PLASMA SPRAYED FEMORAL COMPONENT
2
Cleared 510(K)
K
97
1854
OSTEOLOCK ACETABULAR SHELL SYSTEM
2
Cleared 510(K)
K
97
1718
MICRO-SEAL ACETABULAR SYSTEM
2
Cleared 510(K)
K
97
1429
INTERSEAL ACETABULAR SCREW HOLE PLUG
2
Cleared 510(K)
K
97
0300
NATURAL-HIP SYSTEM POROUS STEM WITH HA/CSTI
2
Cleared 510(K)
K
96
4650
TCP-COATED POROCOAT AML FEMORAL HIP PROSTHESIS
2
Cleared 510(K)
K
96
4509
IMPLEX A-240 HEP ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
97
1020
LSF TRIAD TOTAL HIP SYSTEM
2
Cleared 510(K)
K
97
0705
INTER-OP POROUS REVISION SHELL WITH SEALABLE SCREWHOLES
2
Cleared 510(K)
K
97
0706
INTER-OP POROUS PROTRUSIO SHELL WITH SEALABLE SCREWHOLES
2
Cleared 510(K)
K
97
0501
PEGGED ACETABULAR COMPONENT
2
Cleared 510(K)
K
96
5164
HOWMEDICA MODULAR REPLACEMENT SYSTEM-PROXIMAL FEMUR
2
Cleared 510(K)
K
96
4882
IMPLEX REPLACEMENT ACETABULAR CUP INSERT
2
Cleared 510(K)
K
96
4924
OMEGA TOTAL HIP SYSTEM FOR USE WITHOUT BONE CEMENT (LINE EXTENSION)
2
Cleared 510(K)
K
96
4769
VERSYS HIP SYSTEM--FIBER METAL TAPER HIP PROSTHESIS
2
Cleared 510(K)
K
96
3100
TRONZO ACETABULAR FIXATION COMPONENT (1 99-02-00XX (ACE. FIXATION CUP) XX=OD OF ACE. CUP
2
Cleared 510(K)
K
96
3101
B-P HEMISPHERICAL ACETABULAR COMPONENT
2
Cleared 510(K)
K
96
3998
METAL BACKED ACETABULAR COMPONENT
2
Cleared 510(K)
K
96
3946
OSTEONICS MODULAR ACETABULAR CUP (MICROSTRUCTURED VERSION)
2
Cleared 510(K)
K
96
3509
GLOBAL TAPER TAPERED HIP SYSTEM, GT SPECTRON
2
Cleared 510(K)
K
96
4227
METAL ACETABULAR COMPONENT
2
Cleared 510(K)
K
94
3230
MAYO HIP PROSTHESIS
2
Cleared 510(K)
K
96
3309
APEX HOLE ELIMINATOR PS
2
Cleared 510(K)
K
96
3266
NATURAL HIP SYSTEM POROUS STEM - COLLARLESS, COLLARED
2
Cleared 510(K)
K
96
2769
HORIZON HIP SYSTEM
2
Cleared 510(K)
K
96
2923
DEPUY GRADED POROSITY AML HIP (1371-03/06-500/1371-43/46-500)
2
Cleared 510(K)
K
96
1526
PRESS-FIT POROUS SHELL
2
Cleared 510(K)
K
96
1186
DEPUY DURALOC CEMENTLESS ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
96
1625
QUATROLOC FEMORAL COMPONENT & HEAD
2
Cleared 510(K)
K
96
1939
S-ROM FEMORAL HIP STEM(SIZES 12 X 06 X 115 AND 12 X 07 X 115)
2
Cleared 510(K)
K
95
5563
FOUNDATION FORGED, TEXTURED & POROUS STEMS W/BIOLOX CERAMIC HEADS
2
Cleared 510(K)
K
96
0303
FENNING FEMORAL COMPONENT
2
Cleared 510(K)
K
96
0660
HEMISPHERE ACETABULAR CUP
2
Cleared 510(K)
K
96
0180
22 MM COCR HEAD & POLYETHLENE LINER
2
Cleared 510(K)
K
96
0172
DEPUY POROCOAT HPS II HIP PROSTHESIS W/ARTICUL-EZE TAPER
2
Cleared 510(K)
K
95
5739
MODULAR ACETABULAR SHELL II
2
Cleared 510(K)
K
95
5871
HOWMEDICA ASYMMETRIC STEM FEMORAL COMPONENT
2
Cleared 510(K)
K
95
5511
ARTHOPOR I & II ACETABULAR CUP/ARTHOPOR II OBLONG ACETABULAR CUP
2
Cleared 510(K)
K
95
5170
NEXFLEX FEMORAL STEM, STANDARD DESIGN
2
Cleared 510(K)
K
95
3703
DEPUY VISION SOLUTION HIP PROSTHESIS
2
Cleared 510(K)
K
95
3694
DEPUY VISION AML HIP PROTHESIS
2
Cleared 510(K)
K
95
5033
RIM FLARE ACETABULAR COMPONENT
2
Cleared 510(K)
K
95
5271
MICRO-SEAL ACETABULAR SYSTEM
2
Cleared 510(K)
K
95
4935
S-ROM FEMORAL HIP STEM - SIZE 14 X 8
2
Cleared 510(K)
K
95
3337
BETA HIP PROSTHESIS
2
Cleared 510(K)
K
95
4811
DEPUY ADVANTAGE HIP FEMORAL PROSTHESIS WITH POROCOAT
2
Cleared 510(K)
K
95
4698
TRILOGY ACETABULAR COMPONENT 7MM OFFSET
2
Cleared 510(K)
K
95
4417
A-B ACETABULAR COMPONENT
2
Cleared 510(K)
K
95
4466
PROFORM POROUS BEADED FEMORAL STEM
2
Cleared 510(K)
K
95
4288
EXTEND HIP SYSTEM
2
Cleared 510(K)
K
95
4213
ATH FULL PROFILE ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
95
3664
VITALOCK SPIKED ACETABULAR SHELL
2
Cleared 510(K)
K
95
3490
TRILOGY ACETABULAR SHELL & LINERS 36MM
2
Cleared 510(K)
K
95
2740
DEPUY DURALOC 400 ACETABULAR CUP
2
Cleared 510(K)
K
93
6292
PACKAGING AND MANUFACTURING METHODS CHANGE/KNEE COMPONENTS
2
Cleared 510(K)
K
93
4060
HOWMEDICA(R) ACETABULAR COMP PACK/MANUF METH CHANGE
2
Cleared 510(K)
K
93
3882
OSTEONICS PS HEMI-HIP STEM SERIES
2
Cleared 510(K)
K
95
1741
REPLICA TOTAL HIP SYSTEM
2
Cleared 510(K)
K
95
2397
VITALOCK SOLID BACKED ACETABULAR SHELL
2
Cleared 510(K)
K
94
1612
F-230 POROUS FEMORAL HIP STEM (CEMENTLESS)
2
Cleared 510(K)
K
95
1356
VARIOUS UHMWP HIP & KNEE JOINT PROSTHESIS MODIFIED
2
Cleared 510(K)
K
95
1115
HOWMEDICA VITALOCK 22MM ACERTABULAR SHELL AND SYSTEM 12 INSERTS
2
Cleared 510(K)
K
95
1114
SYSTEM 12 P1 26MM ACETABULAR INSERT
2
Cleared 510(K)
K
93
6310
ORTHOMET HMC FEMORAL STEM COMPONENT
2
Cleared 510(K)
K
94
0715
OSTEONICS OMNIFIT AD HIP STEM SERIES
2
Cleared 510(K)
K
94
4592
PRECISION OSTEOLOCK FEMORAL COMPONENT
2
Cleared 510(K)
K
95
1674
DEPUY DURALOC 100C ACETABULAR CUP
2
Cleared 510(K)
K
95
1095
10.5MM REPLICA HIP STEM
2
Cleared 510(K)
K
95
1301
DEPUY DURALOC CEMENTLESS ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
95
0827
PROFORM POROUS ACETABULAR ASSEMBLY
2
Cleared 510(K)
K
95
1000
ZTT I AND II ACETABULAR CUP OF THE S-ROM TOTAL HIP SYSTEM
2
Cleared 510(K)
K
93
4515
BIAS(TM) FIBER METAL TOTAL HIP STEM (TFB)
2
Cleared 510(K)
K
92
1525
HIP JOINT METAL/POLYMER SEMI-CONSTRAINED PROTHESIS
2
Cleared 510(K)
K
93
4334
APOGEE HIP STEM WITH POROCOAT
2
Cleared 510(K)
K
93
1333
ORTHOMET ACETABULAR CUP SYSTEM
2
Cleared 510(K)
K
94
3054
OSTEONICS SECURE-FIT AD ACETABULAR COMPONENT SYSTEM
2
Cleared 510(K)
K
94
2115
INFINITY REVISION HIP STEM
2
Cleared 510(K)
K
94
1141
PRECISION OSTELOCK SP FEMORAL COMPONENT
2
Cleared 510(K)
K
93
5875
OSTEONICS SCREWLESS ACETABULAR COMPONENTS
2
Cleared 510(K)
K
93
5484
PROVIDENT HIP SYSTEM
2
Cleared 510(K)
K
93
4412
COATED ZT PROXIMAL SLEEVE
2
Cleared 510(K)
K
93
3102
HOWMEDICA ACETABULAR SHELL W/SCREW HOLES
2
Cleared 510(K)
K
93
2924
IMPLEX A-230 POROUS ACETABULAR CUP SYST. CEMENTED
2
Cleared 510(K)
K
93
2755
REFLECTION ACETABULAR COMPONENT
2
Cleared 510(K)
K
93
2923
IMPLEX A-230 POROUS ACETABULAR CUP SYST.CEMENTLESS
2
Cleared 510(K)
K
93
4765
TRILOGY ACETABULAR SYSTEM
2
Cleared 510(K)
K
93
1642
RMHS MONOLITHIC FEMORAL COMPONENT
2
Cleared 510(K)
K
93
3787
POROCOAT POROUS COATING/AML PROXIMALLY-COATED STEM
2
Cleared 510(K)
K
93
1641
POROCOAT POROUS COATING
2
Cleared 510(K)
K
92
6156
REPLICA(TM) TOTAL HIP SYSTEM
2
Cleared 510(K)
K
93
5731
ACETABULAR SHELL
2
Cleared 510(K)
K
92
5172
PCA(R) E SERIES HIP SYSTEM (CEMENTLESS USE)
2
Cleared 510(K)
K
92
2071
ZIMMER ANATOMIC HIP SYSTEM
2
Cleared 510(K)
K
92
1557
BIAS TOTAL HIP SYSTEM ACETABULAR COMPONENT
2
Cleared 510(K)
K
92
1308
HG MULTILOCK HIP PROSTHESIS W/ TI-NIDIUM
2
Cleared 510(K)
K
92
3452
PMI HIP FEMORAL
2
Cleared 510(K)
K
92
1301
TAPERLOC FEMORAL STEM AND UNIVERSAL ACETABULAR COM
2
Cleared 510(K)
K
92
1277
RANAWAT/BURSTEIN TOTAL HIP SYSTEM
2
Cleared 510(K)
K
92
1274
METALLIC TOATAL HIP SYSTEM
2
Cleared 510(K)
K
92
0955
APR(R) HIP SYST & NATURAL-HIP(R) FOR UNCEMENT USE
2
Cleared 510(K)
K
92
2500
PSL TOTAL HIP REPLACEMENT SYSTEM
2
Cleared 510(K)
K
92
1114
EXACTECH MCS POROUS COATED TOTAL HIP ACETABULAR
2
Cleared 510(K)
K
92
1113
EXATECH MCS POROUS COATED TOTAL HIP FEMORAL STEM
2
Cleared 510(K)
K
92
2159
INFINITY POROUS-COATED TROCHANTERIC MODULE
2
Cleared 510(K)
K
92
6107
ARCOM POLYETHYLENE ACETABULAR LINERS & COMPONENTS
2
Cleared 510(K)
K
92
1400
HIP JOINT PROTHESIS
2
Cleared 510(K)
K
92
4492
POLY-DIAL INSERTS
2
Cleared 510(K)
K
92
1639
BIAS TOTAL HIP SYSTEM 300-MM FEMORAL STEM
2
Cleared 510(K)
K
92
0831
PCA TOTAL HIP SYSTEM (CEMENTLESS USE)
2
Cleared 510(K)
P
88
0025
AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS
2
PMA Approval
P
88
0076
WHITESIDE EPS(TM) FEMORAL HIP PROSTHESIS
2
PMA Approval
P
85
0061
BIAS(R) FIBER METAL TOTAL HIP SYSTEM
2
PMA Approval
P
88
0025
DURALOC(TM) 300S ACETABULAR CUP WITH POROCOAT(TM)
2
PMA Approval
P
88
0025
AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS
2
PMA Approval
K
89
6637
ACCESS(TM), SOFTWARE RELEASE 4.11P
2
Cleared 510(K)
P
85
0061
BIAS(R) FIBER METAL TOTAL HIP SYSTEM
2
PMA Approval
K
86
2702
TRI-LOCK II TITANIUM ACETABULUM PROSTHESIS
2
Cleared 510(K)
K
86
2326
POROUS COATED HIP FEMORAL PROSTHESIS
2
Cleared 510(K)
K
86
0442
PRECISION HIP SYSTEM PROXIMAL FEMORAL SPACER #6259
2
Cleared 510(K)
K
86
0635
OPTI-FIX TOTAL HIP SYSTEM
2
Cleared 510(K)
K
85
2198
AML PROXIMAL POROCOAT FEMORAL HIP
2
Cleared 510(K)
K
85
1421
S-ROM ACETABULAR CUP(PART OF S-ROM 135TM TOTAL HIP
2
Cleared 510(K)
K
83
3681
POROCOAT HPS II HIP PROSTHESIS
2
Cleared 510(K)
K
83
3439
POROCOAT NEB TOTAL HIP SYSTEM
2
Cleared 510(K)
K
83
3464
POROCOAT SCHATZKER ACETABULUM
2
Cleared 510(K)
LRN
Wire, Surgical
2
Product Code
LTO
Spacer, Cement
3
Product Code
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
2
Product Code
LYP
Accessories, Fixation, Spinal Interlaminal
2
Product Code
LYT
Fixation Accessory
2
Product Code
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
2
Product Code
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
2
Product Code
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
2
Product Code
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
2
Product Code
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
2
Product Code
MBB
Bone Cement, Antibiotic
2
Product Code
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
2
Product Code
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
2
Product Code
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
2
Product Code
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
2
Product Code
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
2
Product Code
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
2
Product Code
MJW
Prosthesis, Subtalar, Plug, Polymer
2
Product Code
MNH
Orthosis, Spondylolisthesis Spinal Fixation
2
Product Code
MNI
Orthosis, Spinal Pedicle Fixation
2
Product Code
MNU
Staple, Absorbable
2
Product Code
MQP
Spinal Vertebral Body Replacement Device
2
Product Code
MQV
Filler, Bone Void, Calcium Compound
2
Product Code
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
2
Product Code
NDD
Cerclage, Fixation, Metallic
2
Product Code
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
2
Product Code
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
2
Product Code
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDK
System, External Fixator (With Metallic Invasive Components)
2
Product Code
NDL
Pin, Fixation, Smooth, Metallic
2
Product Code
NDM
Pin, Fixation, Threaded, Metallic
2
Product Code
NDN
Cement, Bone, Vertebroplasty
2
Product Code
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
2
Product Code
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
2
Product Code
NKB
Thoracolumbosacral Pedicle Screw System
2
Product Code
NKG
Posterior Cervical Screw System
2
Product Code
NOV
Anchor, Suture, Bone Fixation, Metallic
2
Product Code
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
NQP
Posterior Metal/Polymer Spinal System, Fusion
2
Product Code
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
2
Product Code
NUD
Vertebroplasty Compound, Calcium Based
2
Product Code
NVC
Bone, Heterograft
3
Product Code
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
2
Product Code
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
2
Product Code
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
2
Product Code
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
2
Product Code
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
3
Product Code
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
2
Product Code
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
2
Product Code
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
2
Product Code
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
2
Product Code
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
2
Product Code
OOG
Knee Arthroplasty Implantation System
2
Product Code
OOL
Electronic Depth Gauge
2
Product Code
OQB
Intervertebral Body Graft Containment Device
2
Product Code
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
2
Product Code
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
2
Product Code
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
2
Product Code
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
2
Product Code
OSN
Software For Diagnosis/Treatment
2
Product Code
OUR
Sacroiliac Joint Fixation
2
Product Code
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
2
Product Code
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
2
Product Code
OVZ
Pin, Fixation, Resorbable, Hard Tissue
2
Product Code
OWI
Bone Fixation Cerclage, Sublaminar
2
Product Code
OYK
Ankle Arthroplasty Implantation System
2
Product Code
OZI
Internal Hinged Elbow Fixator
2
Product Code
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
2
Product Code
PBF
Orthopaedic Surgical Planning And Instrument Guides
2
Product Code
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
2
Product Code
PEK
Spinous Process Plate
2
Product Code
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
2
Product Code
PHQ
Anterior Staple As Supplemental Fixation For Fusion
2
Product Code
PHX
Shoulder Prosthesis, Reverse Configuration
2
Product Code
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
2
Product Code
PLF
Bone Wedge
2
Product Code
PLR
Spinal Vertebral Body Replacement Device - Cervical
2
Product Code
PLW
Acetabular Cup Orientation System
2
Product Code
PML
Bone Cement, Posterior Screw Augmentation
2
Product Code
PPQ
Transtibial Anterior Cruciate Ligament Kit
2
Product Code
QHQ
Total Shoulder Arthroplasty System
2
Product Code
PQC
Pedicle Screw Placement Guide
2
Product Code
QAC
Screw Sleeve Bone Fixation Device
2
Product Code
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
2
Product Code
QFP
Intraoperative Orthopedic Strain Sensor
2
Product Code
QHE
Shoulder Arthroplasty Implantation System
2
Product Code
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
2
Product Code
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
2
Product Code
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
2
Product Code
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
2
Product Code
JDK
Prosthesis, Hip, Cement Restrictor
2
Product Code
LZN
Cement Obturator
2
Product Code
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
2
Product Code
QSD
Posterior Cervical Screw Placement Guide
2
Product Code
QSR
Sacroiliac Screw Placement Guide
2
Product Code
QVI
Screw Sleeve Bone Fixation Device, Spine
2
Product Code
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
SAI
Ankle Fusion Cage
2
Product Code
SCY
Sacroiliac Joint Guidewire Placement Device
2
Product Code
Subpart E—Neurological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
OR
/
subpart-d—prosthetic-devices
/
LPH
/
K061226
View Source
TRABECULAR METAL ACETABULAR REVISION SYSTEM CAGE
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K061226
510(k) Type
Traditional
Applicant
Zimmer, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
8/2/2006
Days to Decision
92 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Miscellaneous
Subpart B—Diagnostic Devices
Subpart D—Prosthetic Devices
NDH
Nail, Fixation, Bone, Metallic
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
HSA
Prosthesis, Knee, Hemi-, Femoral
HSB
Rod, Fixation, Intramedullary And Accessories
NDI
Staple, Fixation, Bone, Metallic
HRS
Plate, Fixation, Bone
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
HTN
Washer, Bolt Nut
HTY
Pin, Fixation, Smooth
HWC
Screw, Fixation, Bone
HXA
Prosthesis, Tendon, Passive
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
JDC
Prosthesis, Elbow, Constrained, Cemented
JDD
Prosthesis, Upper Femoral
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
JDN
Implant, Fixation Device, Spinal
JDO
Device, Fixation, Proximal Femoral, Implant
JDP
Condylar Plate Fixation Implant
JDQ
Cerclage, Fixation
JDR
Staple, Fixation, Bone
JDS
Nail, Fixation, Bone
JDT
Cap, Bone
JDW
Pin, Fixation, Threaded
JEC
Component, Traction, Invasive
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
KIG
Prosthesis, Wrist, Constrained, Polymer
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
KWD
Prosthesis, Toe, Hemi-, Phalangeal
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
KWF
Prosthesis, Finger, Polymer
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
KWH
Prosthesis, Toe, Constrained, Polymer
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
KWM
Prosthesis, Wrist, Semi-Constrained
KWN
Prosthesis, Wrist, Carpal Lunate
KWO
Prosthesis, Wrist, Carpal Scaphoid
KWP
Appliance, Fixation, Spinal Interlaminal
KWQ
Appliance, Fixation, Spinal Intervertebral Body
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
KXA
Prosthesis, Hip, Femoral, Resurfacing
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
KXD
Prosthesis, Hip, Constrained, Metal
KXE
Prosthesis, Wrist, Hemi-, Ulnar
KYI
Prosthesis, Wrist, Carpal Trapezium
KYJ
Prosthesis, Finger, Constrained, Polymer
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
KYN
Prosthesis, Wrist, Constrained, Metal
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
LOD
Bone Cement
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
K
25
2067
Velora Acetabular System
K
25
1833
EMPOWR Acetabular® Liner Extension
K
25
1718
ArTT Augments and Buttresses and Bone Screws
K
25
0989
Stryker and Serf hip devices
K
24
3456
ONVOY™ Acetabular System
K
24
2744
Trinity EVO Acetabular Shell
K
24
2232
Mpact 3D Metal Augments II
K
24
2045
Initia T3 Acetabular Hemispherical Shell System
K
24
3784
Stryker Orthopaedics Hip Devices Labeling Update
K
24
3977
EMPHASYS Acetabular System
K
24
1059
Pantheon Proximal Femur Reconstruction (PFR) System
K
24
1636
MobileLink Acetabular Cup System - Line Extension (Multiple)
K
24
2833
Legend® Acetabular Shell
K
24
2375
OR3O Dual Mobility System
K
24
2084
EMPHASYS Acetabular Shell with RapiTite HA
K
24
0046
Ethylene Oxide Sterilization Supplier Change for MPO Hips
K
23
1522
EMPHASYS™ Dual Mobility System
K
23
3498
Stryker Orthopaedics Hip Systems Labeling Update
K
23
2667
OR3O Dual Mobility Liners
K
23
2556
DePuy 3D Additive TriFlange Acetabular Cup and DePuy TriFlange II Acetabular Cup System
K
23
0011
Mpact Extension
K
22
2436
Latitud™ Hip Replacement System
K
22
2066
LINK MobileLink Acetabular Cup System
K
22
3223
BENCOX Mirabo Z Cup Cortinium
K
22
3779
EMPOWR™ blade stem
K
22
3348
My3D® Personalized Pelvic Reconstruction
K
21
1047
CoCr Head
K
22
1675
United U2 femoral head, 22mm delta ceramic head
K
21
3842
ONVOY Acetabular System
K
22
0336
Mg-PSZ Ceramic Femoral Head
K
22
1636
EMPHASYS Acetabular System
K
22
0959
OR3O Dual Mobility System
K
21
2815
My3D® Personalized Pelvic Reconstruction
K
21
1176
Smith & Nephew Hip Systems
K
20
1348
DePuy 3D Additive TriFlange Acetabular Cup
K
21
0614
BENCOX Mirabo Z Cup Cortinium
K
22
0468
BENCOX Mirabo Cup System
K
21
2761
Biocore9 Acetabular Cup System
K
22
0376
Acetabular Dome Hole Plug
K
21
2187
Restoration® Modular Hip System
K
21
1330
R3 Large Head Liners
K
20
2568
Mpact® 3D Metal Implants - DMLS Technology
K
20
0011
E-CLASS® DUAL MOBILITY INSERTS and DYNASTY® DUAL MOBILITY LINERS
K
21
1866
Bencox THR System
K
20
1733
Provident II Hip Stems
K
20
0607
LINK MobileLink® Acetabular Cup System - Dual Mobility Liners, and Shell/Insert Adapters
K
20
0391
MPACT Extension
K
21
0893
Restoration Anatomic Shell
K
20
3557
EMPOWR Dual Mobility Metal Liner, EMPOWR Dual Mobility Poly Bearing
K
20
2472
ACTIS Duofix Hip Prosthesis
K
20
2484
Cordera Hip System
K
20
0854
DePuy PINNACLE Dual Mobility Liner
K
19
1708
Origin Stem, Evolve Stem, Aria Hip Stem, Remedy Stem, CoCr Femoral Head
K
20
0656
Delta Multihole TT Pro Acetabular System
K
19
3233
Restoration® Modular Hip System
K
19
1826
KeYi Total Hip System
K
19
2450
Precision Casting Solutions Total Hip System
K
19
0656
Dual Mobility - Longevity and Vivacit-E Polyethylene Hip Bearings
K
19
0660
G7 Acetabular System Longevity Highly Crosslinked Polyethylene, G7 Acetabular System Vivacit-E Vitamin E Highly Crosslinked Polyethylene
K
19
2919
Pinnacle Duofix HA Acetabular Cup Prosthesis
K
19
2198
Conformis Hip System
K
18
3457
Zimmer Biomet 12/14 CoCr Femoral Head and Freedom Head
K
19
1622
Delta Multihole TT Pro Acetabular System
K
19
1002
OR3O Dual Mobility System
K
19
0847
REDAPT Blade Augments
K
19
1358
Trident II Acetabular System
K
19
2071
iNSitu Total Hip System
K
19
0904
Conformis BeneFIT Hip System
K
19
1936
iNSitu Total Hip System
K
18
3129
Medtronic Total Hip Arthroplasty System
K
19
0123
MicroPort CoCr Femoral Heads
K
19
0057
DJO Acetabular System
K
18
2678
Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology MR Labeling
K
18
2221
Bencox Mirabo Cup Multi Hole
K
18
3582
MPACT Extension
K
18
2468
Trident X3 Acetabular Inserts, ADM and MDM X3 Acetabular Inserts, Accolade II Hip System
K
18
2502
Alteon Acetabular Cup System
K
19
0276
Provident II Hip Stem
K
18
2099
Delta TT Pro
K
18
2109
REDAPT Modular Acetabular Shell
K
18
1366
REDAPT Porous Acetabular Shell
K
17
2857
Latitud Hip Replacement System
K
18
0798
Prime Acetabular Cup System
K
17
2551
Trinity PLUS Acetabular Shell
K
17
3951
Legend Acetabular Liners
K
17
1966
Mpact® 3D Metal™ Implants and Augments 3D Metal™
K
17
2456
Bone Screws 6.5mm
K
17
1934
Birmingham Hip (BH) Dual Mobility Insert
K
17
1073
Smith & Nephew, Inc. REDAPT Augments
K
17
2251
UTS Stem
K
17
2806
Bencox Mirabo Cup System
K
17
2684
Smith & Nephew, Inc. ANTHOLOGY™ AFIT Hip Stem
K
17
1768
Trident® II Acetabular System
K
17
2501
iNSitu Total Hip System
K
17
1962
Klassic HD® Hip System
K
16
2957
U2 Femoral Head
K
17
0444
PROCOTYL® PRIME Acetabular Cup System
K
16
2719
iTotal® Hip Replacement System
K
16
3193
UTF Stem, reduced, #0, #00
K
16
2127
Bencox M Stem Lateralized & Bencox Mirabo Cup System
K
16
1073
Klassic HD Hip System
K
16
1569
Trident® II Tritanium® Acetabular Shells and 6.5 mm Low Profile Hex Screws
K
16
1184
iNSitu Total Hip System
K
15
1424
The Progressive Orthopaedic Total Hip System
K
16
1190
G7 Dual Mobility System, Active Articulation System
K
15
3345
Stryker Orthopaedics Hip Systems Labeling Update
K
16
1080
Escalade Legend Acetabular Shell
K
15
2084
Bencox M Stem (Bencox Hip System) and Bencox ID Cemented Stem (with Centralizer) & Bencox Bone Plug
K
16
0266
ICONACY(TM) I-Hip(TM)
K
15
0790
REDAPT Porous Acetabular Shell and Cemented Liner
K
15
1603
Arcos One-piece Femoral Revision System
K
15
1440
Klassic HD Hip System
K
14
1960
Exactech® Novation® Crown Cup®
K
15
1448
Continuum and Trilogy Integrated Taper (IT) Acetabular Systems
K
15
1316
U2 Hip Stem, Ti Porous Coated, Matrix
K
15
1264
Restoration Anatomic Shell
K
15
0007
Modified Bencox Hip System
K
15
0522
G7 Dual Mobility System
K
15
0503
Echo Bi-Metric Microplasty Line Extension
K
14
3453
Mpact Double Mobility System
K
14
3314
Progressive Orthopaedic Total Hip System
K
14
2119
PROCOTYL L-O ACETABULAR SYSTEM
K
14
2882
G7 Freedom and Offset Liners, Freedom Head, Size 32
K
14
3085
Stryker Orthopaedics Acetabular Shells, Femoral Stems and Total Hip Instruments for use with the Direct Superior Approach
K
14
2606
Trident® Tritanium® PST® Acetabular Shells
K
14
2201
OMNI Interface Acetabular System
K
14
0547
EXCERA FITRITE TOTAL HIP ARTHROPLASTY SYSTEM
K
14
2746
G7 Finned Acetabular Shell
K
14
3009
Echo Bi-Metric Microplasty Hip System
K
14
0669
G7 OSSEOTI ACETUBLAR SHELLS
K
14
2462
Restoration Anatomic Shell
K
14
1676
RENOVIS SURGICAL POROUS ACETABULAR CUP SYSTEM
K
14
1001
ALPINE HIP STEM; ALPINE HA HIP STEM
K
14
1797
ALTEON 6.5MM BONE SCREWS
K
13
3370
REMEDY HIP STEM, PEGASUS HIP STEM, EVOLVE HELIOS HIP STEM, EVOLVE MASTERS HIP STEM, EVOLVE DISTAL CENTRALIZER, EVOLVE CE
K
14
1395
DELTA TT ACETABULAR SYSTEM
K
13
2697
ENCOMPASS 10/12 HIP STEM
K
14
1043
CS2 MULTI-HOLE ACETABULAR SHELL
K
13
2312
RENOVIS TESERA TRABECULAR TECHNOLOGY (T3) ACETABULAR SHELL SYSTEM
K
13
2572
I-HIP TOTAL HIP SYSTEM
K
13
3832
KLASSIC HD HIP SYSTEM, OFFSET FEMORAL STEM, NON-POROUS / POROUS
K
13
3386
OVATION TRIBUTE HIP STEM; OVATION NARROW HIP STEM
K
13
2959
DEPUY PINNACLE ALTRX ACETABULAR LINERS
K
13
2158
NOVOHIP TOTAL HIP SYSTEM
K
13
1454
KLASSIC HD(TM) EXTENDED OFFSET FEMORAL HEAD
K
13
2879
MPACT EXTENSION
K
13
3228
ICONACY I-HIP SYSTEM, GRADUAL TRANSITIONING (GT) FEMORAL SYSTEM
K
13
1022
OVATION 10/12 HIP STEM
K
13
2626
PIPELINE TOTAL HIP SYSTEM (LINE EXTENSION)
K
13
2207
UTF STEM-REDUCED, ADDITIONAL SIZES
K
13
1279
ICONACY I-HIP SYSTEM
K
13
0353
PIPELINE TOTAL HIP SYSTEM (LINE EXTENSION)
K
13
0099
TAPERFILL FEMORAL HIP STEM 425-31-005_017 425-41-005_019
K
13
1237
PIPELINE TOTAL HIP SYSTEM
K
13
0149
U2 HIP SYSTEM, EXPANDED INDICATIONS FOR USE
K
12
3550
UTF STEM, REDUCED
K
12
0599
DEPUY M-SPEC 36MM FEMORAL HEADS
K
13
0063
ARCOS TROCHANTER BUTTON
K
12
1297
ORIGIN HIP STEM, FEMORAL HEAD, LOGICAL PX-SERIES ACETABULAR SHELL, LOCIGAL G-SERIES ACETABULAR SHELL, LOGICAL ACETABULAR
K
11
2898
DELTA TT CUPS, DELTA TT LINERS, BONE SCREWS
K
12
2512
CS2 HIP SYSTEM
K
12
2636
REVELATION POROUS COATED HIP STEM, SIZE 8
K
12
3012
SMITH & NEPHEW SMF HIP STEM
K
12
1636
ZENITH, FEMORAL STEM ZENITH, DISTAL CENTRALIZER FOMORAL HEAD ACETABULAR INSERT
K
12
3019
LONGEVITY IT HIGHLY CROSSLINKED POLYETHYENE LINERS
K
12
2798
INTEGRIP ACETABULAR SHELL, INTEGRIP REVISION ACETABULAR SHELL
K
12
2504
FEMORAL HEADS, 2.5 AND 7.5 MM NECK LENGTH
K
12
2099
BENCOX II STEM, BENCOX METAL HEAD
K
12
1684
NOVATION LPI PRIME FEMORAL STEM
K
11
3296
ZMR HIP SYSTEM KWZ-PROSTHESIS, HIP, CONSTRAINED, CEMENTED OR UNCEMENTED, METAL/POLYMER
K
12
1935
TAPERSET HIP SMALL STEMS
K
12
0924
BENCOX MIRABO CUP BENCOX MIRABO INSERT (STANDARD& ELEVATED TYES) BENCOX MIRABO CUP SCREW HOLE PLUG
K
12
1034
IOI TOTAL HIP
K
12
2244
POLARCUP DUAL MOBILITY SYSTEM
K
12
0030
TAPERLOC COMPLETE SIZE 4MM AND XR 123
K
12
1308
HIP SYSTEMS
K
12
1777
U2 ACETABULAR CUP, PLASMA SPRAY
K
12
1024
LINEAR POROUS COATED HIP STEM, SIZE 5; REVELATION HIP STEM, SIZE 8; FOUNDATION POROUS PRESS FIT STEM, SIZE 8;
K
12
1263
TAPER SET HIP SYSTEM RDP STEM
K
11
2158
MODULUS STEMS, MODULUS NECKS, MODULAR FEMORAL HEADS, CEMENTED CUPS, LOCK BIPOLAR HEADS
K
12
0241
LINEAR HIP STEM, SIZE 5
K
11
3242
APEX ARC HIP STEM
K
11
3609
NOVATION INTEGRIP ACETABULAR AUGMENTS, GROUPS 4 AND 5
K
11
2779
APEX MODULAR ACCTABULAR CUP (NOW NAMED APEX INTERFACE ACETABULAR SYSTEM)
K
11
0135
POLARCUP DUAL MOBILITY SYSTEM
K
11
1472
HELICON HIP SYSTEM, FEMORAL STEM, HELICON HIP SYSTEM, FEMORAL HEAD, COCR, HELICON HIP SYSTEM, ACETABULAR SHELL, HELICON
K
11
0245
UNITED UTF STEM
K
10
3431
COREN TOTAL HIP SYSTEM
K
11
1546
U2 HIP SYSTEM
K
11
0947
APEX K1 HIP STEM
K
10
3662
CONTINUUM AND TRILOGY INTEGRATED TAPER (IT) ACETABULAR SYSTEMS; LONGEVITY IT HIGHLY CROSSLINKED POLYETHYLENE ELEVATED LI
K
10
1072
TRITANIUM PERI-APATITIE ACETABULAR SOLID-BACKED SHELL, TRITANIUM PERI-APATITE
K
11
0542
CONSENSUS BIOLOX DELTA CERAMIC FEMORAL HEAD
K
11
0555
ARCOMXL ACTIVE ARTICULATION
K
10
3721
MPACT ACETABULAR SYSTEM
K
10
3384
ESCALADE ACETABULAR CUP SYSTEM
K
10
2019
RESTORATION ACETABULAR WEDGE AUGMENTS
K
10
3256
SMITH & NEPHEW SMF HIP STEM
K
10
1336
E1 AVANTAGE HEAD
K
10
1229
LONGEVITY IT HIGHLY CROSSLINKED POLYETHYLENE ELEVATED LINERS, CONTINUUM ACETABULAR SYSTEM AND TRILOGY INTEGRATED TAPER
K
10
0445
KLASSIC HD HIP SYSTEM
K
10
2399
CONSENSUS TAPERSET HIP SYSTEM
K
10
3124
SERIES II X3 LARGE DIAMETER ACCETABULAR INSERTS
K
10
2975
NOVATION CROWN CUP WITH INTEGRIP ACETABULAR SHELL, CLUSTER-HOLE
K
10
2423
DEPUY PINNACLE ALTRX ACETABULAR LINERS
K
10
0933
CONSENSUS CS2 PLUS ACETABULAR INSERT
K
10
1761
EXACTECH NOVATION EMPIRE ACETABULAR AUGMENT WITH INTEGRIP MODEL 186-01-08/11/13, 186-02-08/11/13, 186-03-08/11/13
K
10
1976
INTERFACE ACETABULAR SYSTEM, ACETABULAR INSERT +4 OFFSET
K
10
1575
APEX MODULAR HEAD, SIZE 28 ,32, 26 AND 40 MM+10.5 OFFSET, MODELS 302810, 303210,303610,304010
K
10
0269
NOVATION CROWN CUP GXL LINERS
K
09
3561
ZIMMER TRABECULAR METAL MODULAR ACETABULAR SYSTEM
K
09
4045
MODIFICAITON TO: CARDO MEDICAL HIP SYSTEM
K
10
0555
APEX-LNK ACETABULAR INSERT, E, APEX-LNK ACETABULAR INSERT, F, APEX-LNK
K
09
2098
PATIENT SPECIFIC ACETABULAR RECONSTRUCTION PROSTHESIS
K
09
2443
INTERFACE ACETABULAR CUP LINERS
K
09
0897
TRITANIUM NON-MODULAR SHELL & X3 ALL-POLY INSERT
K
09
1508
ZIMMER CONTINUUM ACETABULAR SYSTEM, ZIMMER TRILOGY IT ACETABULAR SYSTEM
K
08
1566
SMITH & NEPHEW OXINIUM DH FEMORAL HEADS
K
08
1679
REVELATION HIP STEM, MODELS, 427-01, 427-02; LINEAR HIP STEM, MODELS 425-00, 425-05
K
08
1171
TRITANIUM ACETABULAR SHELL SYSTEM
K
07
2817
ECHELON TITANIUM HIP SYSTEM
K
08
0625
SMITH & NEPHEW MIS HIP STEM WITH STIKTITE
K
07
3150
APEX-LNK POLY ACETABULAR CUP LINERS
K
07
3068
ACCIN HIP SYSTEM
K
07
2888
REVELATION AND LINEAR HIP STEMS AND FMP ACETABULAR SHELLS (SPIKED, HEMISPHERICAL AND FLARED)
K
07
2417
SMITH & NEPHEW MIS HIP STEM
K
07
2963
DEPUY PINNACLE ALTRX ACETABULAR LINERS
K
07
2154
FOUNDATION (FMP) POROUS COATED SPIKED ACETABULAR SYSTEM
K
07
2101
RIGI-FIX HIP STEM SYSTEM
K
07
1160
REFLECTION, TANDEM UNIPOLAR
K
06
2489
APEX HCLA ACETABULAR CUP LINERS
K
07
1784
DEPUY PINNACLE WITH GRIPTON ACETABULAR CUPS
K
07
0050
VITALITY HIP SYSTEM MODEL#420
K
07
0278
POLARCUP DUAL MOBILITY SYSTEM
K
07
0369
REGENERX RINGLOC + MODULAR ACETABULAR SHELLS
K
06
3822
MODIFICATION TO HIPSTAR FEMORAL STEM
K
06
2775
EUROPEAN STYLE TAPER,PRESS-FIT HIP STEM
K
06
1461
MAYO CONSERVATIVE HIP PROSTHESIS, MODEL 00.65-8026-010-05
K
06
3257
FMP COATED SPIKED ACETABULAR CUP; HEMISPHERICAL ACETABULAR CUP; FLARED RIM ACETABULAR CUP; METAL/METAL ACETABULAR INSERT
K
06
2419
TRIDENT LARGE DIAMETER ACETABULAR INSERTS
K
06
2148
DEPUY PINNACLE ALTRX ACETABULAR CUP LINER
K
06
0072
MONOBLOCK PRESS-FIT HIP STEM
K
06
1434
TRIDENT LARGE DIAMETER HIP SYSTEM
K
06
1226
TRABECULAR METAL ACETABULAR REVISION SYSTEM CAGE
K
06
1786
VERSYS FIBER METAL MIDCOAT LOW HEAD CENTER HIP PROSTHESIS
K
05
3417
M-COR HIP REPLACEMENT SYSTEM
K
06
1168
PCA 36MM FEMORAL HEADS
K
06
1124
ORTHOPEDIC SOURCE PRESS-FIT HIP
K
06
1833
DEPUY AML HIP PROSTHESIS
K
06
1547
DYNASTY ACETABULAR SHELL; DYNASTY A-CLASS POLY ACETABULAR LINER
K
06
0630
REFLECTION 3-HOLE SHELL WITH ASYMMETRIC POROUS COATING
K
06
1067
TRABECULAR METAL ACETABULAR AUGMENTS
K
06
0581
DEPUY SOLUTION SYSTEM HIP PROSTHESIS
K
06
0040
ZIMMER M/L TAPER HIP PROSTHESIS
K
06
0635
CONSENSUS ACETABULAR SHELL SYSTEM
K
05
2996
POROUS TITANIUM ACETABULAR SHELLS
K
05
2089
XR-SERIES BI-METRIC FEMORAL COMPONENTS
K
05
3293
ENCOMPASS 10*17 AND 12*17 EXTENDED PRESS-FIT HIP STEMS
K
05
2321
VERSYS EPOCH FULLCOAT HIP PROSTHESIS
K
06
0031
DEPUY MODULAR M HEADS
K
05
3557
ESKA-LIBUR HIP STEM
K
05
2026
LINEAGE A-CLASS POLY LINER
K
05
2255
ARCOMXL POLYETHYLENE RX90 ACETABULAR LINERS
K
05
0327
E-POLY (VITAMIN E) ACETABULAR LINERS
K
05
1556
ACUMATCH A-SERIES CONNEXION GXL ENHANCED CROSSLINKED POLYTHYLENE
K
05
1491
TRABECULAR METAL PRIMARY HIP PROSTHESIS
K
05
0937
TRABECULAR METAL ACETABULAR REVISION SHELLS
K
04
2989
RX90 LOW PROFILE ACETABULAR SYSTEM
K
04
2565
ENCOMPASS HIP STEM, TRI-PLUS ACETABULAR SHELL, TRI-PLUS DCM LINER
K
04
2051
ARCOMXL POLYETHYLENE LINERS
K
04
3123
APEX MODULAR HA HIP STEM
K
03
3716
TRIDENT ACETABULAR SYSTEM
K
04
2774
MALLORY-HEAD MODULAR CALCAR STEMS WITH INTERLOCKING SLOTS
K
04
3537
TAPERLOC 12/14 TAPER FEMORAL COMPONENTS
K
04
2871
TRABECULAR METAL ACETABULAR AUGMENTS, MODELS 4894-XXX-YY, 02-212-105XX3, 02-212-205XX3, 02-212-305XX3
K
04
1950
APEX K2 HIP SYSTEM
K
04
1850
MEDALLION MODULAR HIP SYSTEM
K
04
2252
NEXFLEX TOTAL HIP SYSTEM
K
03
1402
PERFECTA FEMORAL STEM
K
04
2029
X-SERIES INTEGRAL RPP FEMORAL COMPONENTS
K
04
2776
VERSYS HIP SYSTEM BEADED MIDCOAT LOW HEAD CENTER HIP PROSTHESIS, MODEL 00-7840-XXX-XX
K
04
2337
ZIMMER M/L TAPER HIP PROSTHESIS WITH CALCICOAT CERAMIC COATING
K
04
1906
EXACTECH 12/14 TOTAL HIP SYSTEM
K
04
0191
BICONTACT HIP STEM AND FEMORAL HEAD
K
03
3580
NEXFLEX TOTAL HIP SYSTEM
K
04
1109
ZIMMER ANATOMIC II HIP PROSTHESIS
K
04
0544
DURALOC OPTION ACETABULAR CUP SYSTEM, MODELS 1599-01-044 TO -066, 1599-11-044 TO -062 AND 1599-21-044 TO -062
K
04
0412
TRIDENT T ACETABULAR SHELLS
K
04
0383
TRIFLANGE II ACETABULAR CUP SYSTEM
K
03
3273
DEPUY PINNACLE ACETABULAR CUP SYSTEM, ESL MARATHON POLYETHYLENE LINERS, AND DEPUY ULTIMA UNIPOLAR FEMORAL HEADS
K
03
3893
SPECTRUM MODULAR SYSTEM
K
03
3338
PINNACLE REVISION SYSTEM
K
03
2729
Z-SERIES MODULAR TOTAL HIP SYSTEM
K
03
2964
EXACTECH 12/14 ALUMINA FEMORAL HEAD; EXACTECH ACUMATCH M-SERIES 12/14 NECK SEGMENTS
K
03
3034
VERSYS BEADED FULLCOAT CALCAR HIP PROSTHESIS
K
03
2385
GLOBAL PRESS-FIT STEM
K
03
2726
ZIMMER M/L TAPER HIP PROSTHESIS, 7711 SERIES
K
03
2581
GLOBAL MODULAR REPLACEMENT SYSTEM ANTEVERTED PROMIMAL FEMORAL COMPONENT
K
03
0055
MALLORY/HEAD TOTAL HIP SYSTEM; HA MALLORY/HEAD TOTAL HIP SYSTEM; BI-METRIC FEMORAL COMPONENTS
K
03
1693
MALLORY/HEAD MODULAR CALCAR WITH AND WITHOUT HA
K
03
1572
ZMR HIP SYSTEM-XL, MODELS 9921, 9922 AND 9923
K
03
0861
HA PMI FLANGED ACETABULAR COMPONENT
K
03
1495
PINNACLE DUOFIX HA ACETABULAR CUP PROSTHESIS
K
03
1110
APEX MODULAR ACETABULAR CUP
K
03
0733
MAYO CONSERVATIVE HIP PROSTHESIS, MODEL 8026 SERIES
K
03
0979
MODIFICATION TO DEPUY SOLUTION SYSTEM HIP PROSTHESIS
K
03
0501
X-SERIES INTEGRAL LATERALIZED HIP COMPONENTS
K
02
1878
ESKA MODULAR HIP SYSTEM ACETABULAR COMPONENTS
K
02
2520
U2 ACETABULAR CUP
K
03
0236
ACUMATCH P-SERIES POROUS PRESS-FIT FEMORAL COMPONENT
K
03
0079
VERSYS BEADED FULLCOAT BOWED REVISION HIP PROSTHESIS
K
03
0048
HA PMI FEMORAL HIP STEM
K
02
3409
HA X-SERIES BI-METRIC HIP FEMORAL COMPONENTS
K
02
3357
ARCPM 1050 RESIN-HIPS
K
02
3375
MODIFICATION TO ESOP CO-CR FEMORAL HEADS
K
02
2382
RHS ACETABULAR COMPONENT
K
02
2902
SMITH & NEPHEW HIP SYSTEM
K
02
1891
ZIMMER TRABECULAR METAL MODULAR ACETABULAR SYSTEM
K
02
2556
REFLECTION MODIFIED ACETABULAR SHELLS
K
02
2711
MODIFICATION TO AVALON CUP SYSTEM
K
02
2463
HA MODULAR REACH PROXIMAL POROUS AND HA MODULAR REACH COLLARED PROXIMAL POROUS FEMORAL STEMS
K
01
4070
EPOCH HIP PROSTHESIS, MODEL 4075 SERIES
K
02
1466
CONSENSUS ACETABULAR INSERT, CROSS-LINKED POLYETHYLENE
K
02
1970
THE TRABECULAR METAL MONOBLOCK CUP, MODELS 00-7259-0XX-28 (ZIMMER CAT. #) AND 02-293-28XX1 (IMPLEX PART #)
K
02
1911
TRIDENT CROSSFIRE POLYUETHYLENE LINERS
K
02
1346
STEM HIP REPLACEMENT SYSTEM, MODEL PHA002XX
K
02
1109
ESOP CO-CR FEMORAL HEADS
K
02
0145
ORTHOPAEDIC INNOVATIONS RENEWAL ACETABULAR CUP SYSTEM
K
02
0153
CONSENSUS ACETABLAR SHELL, TI COATED
K
02
0580
X-SERIES BI-METRIC HIP FEMORAL COMPONENTS
K
01
2787
VAPORIZED HYDROGEN PEROXIDE (VHP) STERILIZATION OF UHMWPE COMPONENTS IN THE REFLECTION ACTABULAR SYSTEM (ACETABULAR LINE
K
02
0497
TRIDENT ELEVATED RIM LINER
K
02
0170
KEYSTONE HIP SYSTEM CALCAR REPLACEMENT BODY AND BUILD UP
K
01
3490
CEMENTED CALCAR HIP SYSTEM
K
01
3475
TRIDENT POROUS TITANIUM ACETABULAR COMPONENT WITH PERI-APATITE COATING
K
01
3658
MODIFICATION TO REFLECTION CROSS-LINKED UHMWPE ACETABULAR COMPONENTS
K
01
2739
CONVERGE ACETABULAR SYSTEM
K
01
2364
AML HIP PROSTHESIS
K
01
2507
THE TRABECULAR METAL TECHNOLOGY ACETABULAR AUGMENT SYSTEM, MODELS 4893-XX-YY (ZIMMER), 02-212-05XX1 ( IMPLEX)
K
01
1489
SUMMIT DUOFIX HIP PROSTHESIS
K
01
1081
ACUMATCH M-SERIES EXTRA-SMALL METAPHYSEAL SEGMENTS
K
01
0170
TRIDENT POROUS TITANIUM ACETABULAR COMPONENT
K
01
0171
DURALOC ACETABULAR CUP SYSTEM, 36MM MARATHON +4 POLYETHYLENE LINER
K
01
0367
MODIFICATION TO TITANIUM TRI-LOCK HIPS STEM
K
00
3875
TI-REPLICA HIP STEM
K
00
4032
PERFECTA AND EXTEND
K
01
0282
LATERAL OFFSET PROTRACT PRESS FIT HIP STEM
K
01
0120
MODIFICATION TO EXACTECH ACUMATCH INTEGRATED HIP SYSTEM, M-SERIES HIGH OFF-SET NECK SEGMENT, M-SERIES LOW OFF-SET NECK S
K
00
3800
AML HIP PROSTHESIS
K
01
0241
PROTRACT PRESS FIT HIP STEM-HA COATED
K
00
3478
TRIOLOGY ACETABULAR SYSTEM 46MM LARGE HEAD LINERS, MODEL 6310
K
00
3237
U2 HIP STEM, TI POROUS COATED
K
00
3199
TRIAD II MODULAR TOTAL HIP SYSTEM
K
00
3447
PROTRACT PRESS FIT HIP STEM
K
00
2747
REFLECTION CROSS-LINKED UHMWPE ACETABULAR COMPONENTS
K
00
2960
TRILOGY ACETABULAR SYSTEM LARGE HEAD LINER, MODEL 6353
K
99
4078
U1 HIP SYSTEM
K
00
3429
MALLOY/HEAD LATERALIZED PRESS-FIT FEMORAL
K
00
3181
IMPLEX CONTINUUM HIP SYSTEM ACETABULAR COMPONENTS - MODEL XX-YYY-ZZZZ
K
00
2149
LINEAGE ACETABULAR SYSTEM
K
00
1991
TITAN POROCOAT HIP PROSTHESIS
K
00
0788
APEX MODULAR HIP STEM
K
00
1982
TRI-LOCK HIP STEM
K
00
1778
POROCOAT PRODIGY HIP PROSTHESIS
K
00
1320
SULZER ORTHOPEDICS INC. NATURAL-HIP SYSTEM LD STEM
K
00
1277
TRIFLANGE ACETABULAR CUP SYSTEM
K
00
1039
THE IMPLEX HEDROCEL MODULAR ELLIPTICAL ACETABULAR CUP
K
00
1660
MALLORY HEAD MODULAR CALCAR
K
00
1534
PINNACLE ACETABULAR SYSTEM
K
00
0760
REACH FEMORAL COMPONENT
K
00
0521
KEYSTONE HIP
K
99
0830
MALLORY/HEAD CALCAR REPLACEMENT WITH INTERLOCKING SLOTS BI-METRIC POROUS COLLARED STEM WITH INTERLOCKING SLOTS
K
00
0321
HEMISPHERE MODULAR CUP SYSTEM
K
99
3027
ESKA MODULAR HIP SYSTEM
K
99
2154
BICON-PLUS ACETABULAR COMPONENTS
K
00
0306
PINNACLE ACETABULAR SYSTEM
K
00
0538
MALLORY/HEAD LATERALIZED PRESS-FIT FEMORAL
K
99
4286
ZMR HIP SYSTEM-POROUS REVISION
K
99
3259
INTER-OP DURASUL ACETABULAR INSERTS/COCR FEMORAL HEADS
K
00
0335
MALLORY-HEAD MODULAR CALCAR TOTAL HIP SYSTEM
K
00
0334
IMPACT MODULAR TOTAL HIP SYSTEM
K
00
0207
POROCOAT PRODIGY HIP PROSTHESIS
K
99
4415
MARATHON CROSS-LINKED POLYETHYLENE ACETABULAR CUP LINERS
K
99
4070
REVELATION POROUS HIP STEM
K
99
3736
EXACTECH ACUMATCH INTEGRATED HIP SYSTEM M-SERIES FEMORAL STEM COMPONENT
K
99
4038
MODULAR REACH HIP
K
99
0849
DURATION IV STERILIZATION PROCESS (ACETABULAR INSERTS)
K
99
3352
CROSSFIRE SYSTEM 12 ACETABULAR INSERTS
K
99
3082
EXACTECH ACUMATCH INTEGRATED HIP SYSTEM A-SERIES POROUS COATED ACETABULAR COMPONENT
K
99
2667
ZMR HIP SYSTEM-REVISION TAPER
K
99
1026
REFLECTION CROSSLINKED UHMWPE ACETABULAR COMPONENTS
K
99
2109
ENCORE FULLY COATED HIP
K
99
1485
SYNERGY POROUS SIZE 8 HIP STEM
K
99
0135
TRILOGY ACETABULAR SYSTEM LONGEVITY CROSSLINKED POLYETHYLENE
K
99
1807
TITANIUM LOW PROFILE SCREWS
K
98
3837
HEDROCEL ACETABULAR CAGE SYSTEM
K
99
1325
MODIFICATION OF ENCORE LINEAR POROUS COATED HIP
K
99
1123
PERFECTA RS LATERALIZED HIP STEM, BRIDGE HIP SYSTEM
K
99
0523
B2C, ESPACE REVISION CUP SYSTEM
K
98
4492
TIGRAN HIP PROSTHESIS
K
99
0003
J-SERIES OMEGA TOTAL HIP SYSTEM
K
98
3834
ECHELON HIP STEM
K
98
4296
LATERALIZED INTERGRAL POROUS PRIMARY FEMORAL COMPONENT
K
98
4408
130 MODIFIED INTEGRAL FEMORAL COMPONENT
K
98
3509
INTER-OP ACETABULAR SYSTEM - DURASUL ACETABULAR INSERT
K
98
4459
DEPUY PROFILE FEMORAL HIP WITH POROCOAT
K
98
3502
OSTEONICS SECUR-FIT AD GENERATION II ACETABULAR COMPONENT SYSTEM
K
98
3491
DEPUY DURALOC ACETABULAR CUP SYSTEM-ENDURON LINER
K
98
3035
CUSTOM FLANGED ACETABULAR COMPONENT
K
98
0711
HARRIS/GALANTE POROUS (HGP) HIP PROSTHESIS WITH CALCICOAT CERAMIC COATING
K
98
3014
SUMMIT ACETABULAR SYSTEM
K
98
2248
HOWMEDICA ASYMMETRIC STEM VITALOCK CLUSTER & SPIKED SHELLS, AND ACETABULAR SHELLS WITH MESH INGROWTH SURFACE WITH PERI-A
K
98
2367
REACH HIP COMPONENT
K
98
1211
APR -T REVISION HIP STEM
K
98
0981
OMEGA HA COATED TOTAL HIP SYSTEM
K
98
0020
ACTIVELOCK MODULAR FEMORAL HIP SYSTEM
K
97
4740
DEPUY TRI-LOCK HIP STEM
K
97
4506
LSF HA COATED TRIAD TOTAL HIP SYSTEM
K
97
1206
MERIDIAN ST FEMORAL STEM AND VITALOCK SOLID BACK SHELL W/ PERI-APATITE COATING
K
97
4331
UNI-ROM TOTAL HIP SYSTEM FEMORAL STEM
K
97
4093
FOUNDATION POROUS COATED HEMISPHERICAL SHELL
K
97
4095
FOUNDATION POROUS COATED FLARED RIM SHELL
K
97
3119
FOUNDATION POROUS ACETABULAR SYSTEM
K
97
4294
ENCORE LINEAR POROUS COATED HIP
K
97
3714
VERSYS HIP SYSTEM BEADED HIP PROSTHESIS
K
97
3685
REVELATION POROUS HIP STEM
K
97
3675
NATURAL-HIP POROUS STEM WITH OFFSET
K
97
1824
REACH FEMORAL HIP COMPONENT
K
97
3302
FOUNDATION POROUS HIP STEM
K
97
3163
ACETABULAR SHELLS WITH MESH INGROWTH SURFACE
K
97
2596
DEPUY DURALOC ACETABULAR CUP SYSTEM
K
97
3124
APR POROUS HA HIP SYSTEM
K
97
1018
SMC ACETABULAR COMPONENT
K
97
3530
INFINTY DISTAL FEMORAL COMPONENT
K
97
2393
INTER-OP HA POROUS ACETABULAR SYSTEM (HA/CSTI)
K
97
0241
DEPUY PROXIMAL FEMORAL REPLACEMENT PROSTHESIS
K
96
4616
QUATROLOC PLASMA SPRAYED FEMORAL COMPONENT
K
97
1854
OSTEOLOCK ACETABULAR SHELL SYSTEM
K
97
1718
MICRO-SEAL ACETABULAR SYSTEM
K
97
1429
INTERSEAL ACETABULAR SCREW HOLE PLUG
K
97
0300
NATURAL-HIP SYSTEM POROUS STEM WITH HA/CSTI
K
96
4650
TCP-COATED POROCOAT AML FEMORAL HIP PROSTHESIS
K
96
4509
IMPLEX A-240 HEP ACETABULAR CUP SYSTEM
K
97
1020
LSF TRIAD TOTAL HIP SYSTEM
K
97
0705
INTER-OP POROUS REVISION SHELL WITH SEALABLE SCREWHOLES
K
97
0706
INTER-OP POROUS PROTRUSIO SHELL WITH SEALABLE SCREWHOLES
K
97
0501
PEGGED ACETABULAR COMPONENT
K
96
5164
HOWMEDICA MODULAR REPLACEMENT SYSTEM-PROXIMAL FEMUR
K
96
4882
IMPLEX REPLACEMENT ACETABULAR CUP INSERT
K
96
4924
OMEGA TOTAL HIP SYSTEM FOR USE WITHOUT BONE CEMENT (LINE EXTENSION)
K
96
4769
VERSYS HIP SYSTEM--FIBER METAL TAPER HIP PROSTHESIS
K
96
3100
TRONZO ACETABULAR FIXATION COMPONENT (1 99-02-00XX (ACE. FIXATION CUP) XX=OD OF ACE. CUP
K
96
3101
B-P HEMISPHERICAL ACETABULAR COMPONENT
K
96
3998
METAL BACKED ACETABULAR COMPONENT
K
96
3946
OSTEONICS MODULAR ACETABULAR CUP (MICROSTRUCTURED VERSION)
K
96
3509
GLOBAL TAPER TAPERED HIP SYSTEM, GT SPECTRON
K
96
4227
METAL ACETABULAR COMPONENT
K
94
3230
MAYO HIP PROSTHESIS
K
96
3309
APEX HOLE ELIMINATOR PS
K
96
3266
NATURAL HIP SYSTEM POROUS STEM - COLLARLESS, COLLARED
K
96
2769
HORIZON HIP SYSTEM
K
96
2923
DEPUY GRADED POROSITY AML HIP (1371-03/06-500/1371-43/46-500)
K
96
1526
PRESS-FIT POROUS SHELL
K
96
1186
DEPUY DURALOC CEMENTLESS ACETABULAR CUP SYSTEM
K
96
1625
QUATROLOC FEMORAL COMPONENT & HEAD
K
96
1939
S-ROM FEMORAL HIP STEM(SIZES 12 X 06 X 115 AND 12 X 07 X 115)
K
95
5563
FOUNDATION FORGED, TEXTURED & POROUS STEMS W/BIOLOX CERAMIC HEADS
K
96
0303
FENNING FEMORAL COMPONENT
K
96
0660
HEMISPHERE ACETABULAR CUP
K
96
0180
22 MM COCR HEAD & POLYETHLENE LINER
K
96
0172
DEPUY POROCOAT HPS II HIP PROSTHESIS W/ARTICUL-EZE TAPER
K
95
5739
MODULAR ACETABULAR SHELL II
K
95
5871
HOWMEDICA ASYMMETRIC STEM FEMORAL COMPONENT
K
95
5511
ARTHOPOR I & II ACETABULAR CUP/ARTHOPOR II OBLONG ACETABULAR CUP
K
95
5170
NEXFLEX FEMORAL STEM, STANDARD DESIGN
K
95
3703
DEPUY VISION SOLUTION HIP PROSTHESIS
K
95
3694
DEPUY VISION AML HIP PROTHESIS
K
95
5033
RIM FLARE ACETABULAR COMPONENT
K
95
5271
MICRO-SEAL ACETABULAR SYSTEM
K
95
4935
S-ROM FEMORAL HIP STEM - SIZE 14 X 8
K
95
3337
BETA HIP PROSTHESIS
K
95
4811
DEPUY ADVANTAGE HIP FEMORAL PROSTHESIS WITH POROCOAT
K
95
4698
TRILOGY ACETABULAR COMPONENT 7MM OFFSET
K
95
4417
A-B ACETABULAR COMPONENT
K
95
4466
PROFORM POROUS BEADED FEMORAL STEM
K
95
4288
EXTEND HIP SYSTEM
K
95
4213
ATH FULL PROFILE ACETABULAR CUP SYSTEM
K
95
3664
VITALOCK SPIKED ACETABULAR SHELL
K
95
3490
TRILOGY ACETABULAR SHELL & LINERS 36MM
K
95
2740
DEPUY DURALOC 400 ACETABULAR CUP
K
93
6292
PACKAGING AND MANUFACTURING METHODS CHANGE/KNEE COMPONENTS
K
93
4060
HOWMEDICA(R) ACETABULAR COMP PACK/MANUF METH CHANGE
K
93
3882
OSTEONICS PS HEMI-HIP STEM SERIES
K
95
1741
REPLICA TOTAL HIP SYSTEM
K
95
2397
VITALOCK SOLID BACKED ACETABULAR SHELL
K
94
1612
F-230 POROUS FEMORAL HIP STEM (CEMENTLESS)
K
95
1356
VARIOUS UHMWP HIP & KNEE JOINT PROSTHESIS MODIFIED
K
95
1115
HOWMEDICA VITALOCK 22MM ACERTABULAR SHELL AND SYSTEM 12 INSERTS
K
95
1114
SYSTEM 12 P1 26MM ACETABULAR INSERT
K
93
6310
ORTHOMET HMC FEMORAL STEM COMPONENT
K
94
0715
OSTEONICS OMNIFIT AD HIP STEM SERIES
K
94
4592
PRECISION OSTEOLOCK FEMORAL COMPONENT
K
95
1674
DEPUY DURALOC 100C ACETABULAR CUP
K
95
1095
10.5MM REPLICA HIP STEM
K
95
1301
DEPUY DURALOC CEMENTLESS ACETABULAR CUP SYSTEM
K
95
0827
PROFORM POROUS ACETABULAR ASSEMBLY
K
95
1000
ZTT I AND II ACETABULAR CUP OF THE S-ROM TOTAL HIP SYSTEM
K
93
4515
BIAS(TM) FIBER METAL TOTAL HIP STEM (TFB)
K
92
1525
HIP JOINT METAL/POLYMER SEMI-CONSTRAINED PROTHESIS
K
93
4334
APOGEE HIP STEM WITH POROCOAT
K
93
1333
ORTHOMET ACETABULAR CUP SYSTEM
K
94
3054
OSTEONICS SECURE-FIT AD ACETABULAR COMPONENT SYSTEM
K
94
2115
INFINITY REVISION HIP STEM
K
94
1141
PRECISION OSTELOCK SP FEMORAL COMPONENT
K
93
5875
OSTEONICS SCREWLESS ACETABULAR COMPONENTS
K
93
5484
PROVIDENT HIP SYSTEM
K
93
4412
COATED ZT PROXIMAL SLEEVE
K
93
3102
HOWMEDICA ACETABULAR SHELL W/SCREW HOLES
K
93
2924
IMPLEX A-230 POROUS ACETABULAR CUP SYST. CEMENTED
K
93
2755
REFLECTION ACETABULAR COMPONENT
K
93
2923
IMPLEX A-230 POROUS ACETABULAR CUP SYST.CEMENTLESS
K
93
4765
TRILOGY ACETABULAR SYSTEM
K
93
1642
RMHS MONOLITHIC FEMORAL COMPONENT
K
93
3787
POROCOAT POROUS COATING/AML PROXIMALLY-COATED STEM
K
93
1641
POROCOAT POROUS COATING
K
92
6156
REPLICA(TM) TOTAL HIP SYSTEM
K
93
5731
ACETABULAR SHELL
K
92
5172
PCA(R) E SERIES HIP SYSTEM (CEMENTLESS USE)
K
92
2071
ZIMMER ANATOMIC HIP SYSTEM
K
92
1557
BIAS TOTAL HIP SYSTEM ACETABULAR COMPONENT
K
92
1308
HG MULTILOCK HIP PROSTHESIS W/ TI-NIDIUM
K
92
3452
PMI HIP FEMORAL
K
92
1301
TAPERLOC FEMORAL STEM AND UNIVERSAL ACETABULAR COM
K
92
1277
RANAWAT/BURSTEIN TOTAL HIP SYSTEM
K
92
1274
METALLIC TOATAL HIP SYSTEM
K
92
0955
APR(R) HIP SYST & NATURAL-HIP(R) FOR UNCEMENT USE
K
92
2500
PSL TOTAL HIP REPLACEMENT SYSTEM
K
92
1114
EXACTECH MCS POROUS COATED TOTAL HIP ACETABULAR
K
92
1113
EXATECH MCS POROUS COATED TOTAL HIP FEMORAL STEM
K
92
2159
INFINITY POROUS-COATED TROCHANTERIC MODULE
K
92
6107
ARCOM POLYETHYLENE ACETABULAR LINERS & COMPONENTS
K
92
1400
HIP JOINT PROTHESIS
K
92
4492
POLY-DIAL INSERTS
K
92
1639
BIAS TOTAL HIP SYSTEM 300-MM FEMORAL STEM
K
92
0831
PCA TOTAL HIP SYSTEM (CEMENTLESS USE)
P
88
0025
AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS
P
88
0076
WHITESIDE EPS(TM) FEMORAL HIP PROSTHESIS
P
85
0061
BIAS(R) FIBER METAL TOTAL HIP SYSTEM
P
88
0025
DURALOC(TM) 300S ACETABULAR CUP WITH POROCOAT(TM)
P
88
0025
AML(R) POROCOAT(R) ACETABULAR CUP PROSTHESIS
K
89
6637
ACCESS(TM), SOFTWARE RELEASE 4.11P
P
85
0061
BIAS(R) FIBER METAL TOTAL HIP SYSTEM
K
86
2702
TRI-LOCK II TITANIUM ACETABULUM PROSTHESIS
K
86
2326
POROUS COATED HIP FEMORAL PROSTHESIS
K
86
0442
PRECISION HIP SYSTEM PROXIMAL FEMORAL SPACER #6259
K
86
0635
OPTI-FIX TOTAL HIP SYSTEM
K
85
2198
AML PROXIMAL POROCOAT FEMORAL HIP
K
85
1421
S-ROM ACETABULAR CUP(PART OF S-ROM 135TM TOTAL HIP
K
83
3681
POROCOAT HPS II HIP PROSTHESIS
K
83
3439
POROCOAT NEB TOTAL HIP SYSTEM
K
83
3464
POROCOAT SCHATZKER ACETABULUM
LRN
Wire, Surgical
LTO
Spacer, Cement
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
LYP
Accessories, Fixation, Spinal Interlaminal
LYT
Fixation Accessory
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
MBB
Bone Cement, Antibiotic
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
MJW
Prosthesis, Subtalar, Plug, Polymer
MNH
Orthosis, Spondylolisthesis Spinal Fixation
MNI
Orthosis, Spinal Pedicle Fixation
MNU
Staple, Absorbable
MQP
Spinal Vertebral Body Replacement Device
MQV
Filler, Bone Void, Calcium Compound
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
NDD
Cerclage, Fixation, Metallic
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
NDK
System, External Fixator (With Metallic Invasive Components)
NDL
Pin, Fixation, Smooth, Metallic
NDM
Pin, Fixation, Threaded, Metallic
NDN
Cement, Bone, Vertebroplasty
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
NKB
Thoracolumbosacral Pedicle Screw System
NKG
Posterior Cervical Screw System
NOV
Anchor, Suture, Bone Fixation, Metallic
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
NQP
Posterior Metal/Polymer Spinal System, Fusion
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
NUD
Vertebroplasty Compound, Calcium Based
NVC
Bone, Heterograft
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
OOG
Knee Arthroplasty Implantation System
OOL
Electronic Depth Gauge
OQB
Intervertebral Body Graft Containment Device
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
OSN
Software For Diagnosis/Treatment
OUR
Sacroiliac Joint Fixation
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
OVZ
Pin, Fixation, Resorbable, Hard Tissue
OWI
Bone Fixation Cerclage, Sublaminar
OYK
Ankle Arthroplasty Implantation System
OZI
Internal Hinged Elbow Fixator
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
PBF
Orthopaedic Surgical Planning And Instrument Guides
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
PEK
Spinous Process Plate
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
PHQ
Anterior Staple As Supplemental Fixation For Fusion
PHX
Shoulder Prosthesis, Reverse Configuration
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
PLF
Bone Wedge
PLR
Spinal Vertebral Body Replacement Device - Cervical
PLW
Acetabular Cup Orientation System
PML
Bone Cement, Posterior Screw Augmentation
PPQ
Transtibial Anterior Cruciate Ligament Kit
QHQ
Total Shoulder Arthroplasty System
PQC
Pedicle Screw Placement Guide
QAC
Screw Sleeve Bone Fixation Device
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
QFP
Intraoperative Orthopedic Strain Sensor
QHE
Shoulder Arthroplasty Implantation System
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
JDK
Prosthesis, Hip, Cement Restrictor
LZN
Cement Obturator
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
QSD
Posterior Cervical Screw Placement Guide
QSR
Sacroiliac Screw Placement Guide
QVI
Screw Sleeve Bone Fixation Device, Spine
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
SAI
Ankle Fusion Cage
SCY
Sacroiliac Joint Guidewire Placement Device
Subpart E—Neurological Surgical Devices
Subpart E—Surgical Devices
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OR
/
subpart-d—prosthetic-devices
/
LPH
/
K061226
View Source
TRABECULAR METAL ACETABULAR REVISION SYSTEM CAGE
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K061226
510(k) Type
Traditional
Applicant
Zimmer, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
8/2/2006
Days to Decision
92 days
Submission Type
Summary