TECHTONIX SYSTEM

K050189 · Stryker Spine · KWP · Feb 16, 2005 · Orthopedic

Device Facts

Record IDK050189
Device NameTECHTONIX SYSTEM
ApplicantStryker Spine
Product CodeKWP · Orthopedic
Decision DateFeb 16, 2005
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 888.3050
Device ClassClass 2
AttributesTherapeutic

Intended Use

As a posterior, non-pedicle screw system of the T4-S2 spine, the Osteonics® Spinal System Rod/Plate System and Techtonix™ System are indicated for: Long and short curve scoliosis Vertebral fracture or dislocation Spondylolisthesis Begenerative disc disease (defined as back pain of discogneic origin with degeneration of the disc confirmed by history and radiographic studies) Previously failed fusion Spinal tumor Pedicular Use: When used as a pedicle screw fixation system of the non-cervical posterior spine in skeletally mature patients, the Osteonics Spinal System Rod/Plate System and Techtonix "M System are indicated for one or more of the following: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudoarthrosis). In addition, the Osteonics® Spinal System Rod/Plate System and Techtonix™ System are indicated for pedicle screw fixation in skeletally mature patients with severe spondylolisthesis (Grades 3 and 4) at the L5-S1 joint, having fusions with autogenous bone graft, having the device fixed or attached to the lumbar and sacral spine (with pedicle placement at L3 and below) with removal of the implants after the development of a solid fusion mass.

Device Story

Techtonix™ System is a low-profile posterior plate system; line extension to Osteonics® Spinal System Rod/Plate System. Comprised of anatomically shaped titanium alloy plates, bone screws, and blockers. Used by surgeons in clinical settings for spinal fixation. Components provide structural support to stabilize spine during fusion procedures. Mechanical properties verified via bench testing to ensure equivalence to predicate. Non-sterile delivery.

Clinical Evidence

Bench testing only. No clinical data presented.

Technological Characteristics

Titanium alloy (ASTM F-136, ISO 5832-3). Low-profile posterior plate system. Components include anatomical plates, bone screws, and blockers. Non-sterile.

Indications for Use

Indicated for T4-S2 posterior non-pedicle fixation or non-cervical pedicle screw fixation in skeletally mature patients. Conditions include scoliosis, vertebral fracture/dislocation, spondylolisthesis, degenerative disc disease, failed fusion, kyphosis, and spinal tumor. Specific indication for severe spondylolisthesis (Grades 3-4) at L5-S1 with autogenous bone graft.

Regulatory Classification

Identification

A spinal interlaminal fixation orthosis is a device intended to be implanted made of an alloy, such as stainless steel, that consists of various hooks and a posteriorly placed compression or distraction rod. The device is implanted, usually across three adjacent vertebrae, to straighten and immobilize the spine to allow bone grafts to unite and fuse the vertebrae together. The device is used primarily in the treatment of scoliosis (a lateral curvature of the spine), but it also may be used in the treatment of fracture or dislocation of the spine, grades 3 and 4 of spondylolisthesis (a dislocation of the spinal column), and lower back syndrome.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ 5050189 Line Extension to the Osteonics® Spinal System RPS ## FEB 1 6 2005 Special 510(k) Premarket Notification # Special 510(k) Summary of Safety and Effectiveness: Line Extension to the Osteonics® Spinal System Rod/Plate System (RPS) | Proprietary Name: | Techtonix™ System | |----------------------------|--------------------------------------------------------| | Common Name: | Spinal Fixation Appliances | | Proposed Regulatory Class: | Class II | | | Spinal Interlaminal Fixation Orthosis, 21 CFR 888.3050 | | | Pedicle Screw Spinal System, 21 CFR 888.3070 | | Device Product Code: | 87 MNH: Spondylolisthesis Spinal Fixation System | | | 87 KWP: Appliance, Fixation, Spinal Interlaminal | | For Information contact: | Simona Voic | | | Regulatory Affairs Project Manager | | | 2 Pearl Court | | | Allendale, NJ 07401 | | | Telephone: (201) 760-8145 | | | Fax: (201) 760-8345 | | | Email: Simona.Voic@stryker.com | Date Summary Prepared: January 26, 2005 ### Predicate Device Identification The features of the Techtonix " System are substantially equivalent to the features of the Osteonics Spinal System Rod/ Plate System (RPS) which was determined substantially equivalent via 510(k) K991055. ### Description of Device Modification This submission is intended to expand the Osteonics® Spinal System Rod/ Plate System product line by adding the Techtonix™ System, a low profile posterior plate system. Similar to its predicate device, the Techtonix™ System is comprised of anatomical shaped plates and bone screws available in a variety of lengths, and blockers (which tighten the bone screws to the plates). The components of the subject device are fabricated from Titanium alloy as described in ASTM F-136 and ISO 5832-3. The Techtonix™ System will be provided non-sterile. Page 1 of 2 2 {1}------------------------------------------------ #### Intended Use: As a posterior, non-pedicle screw system of the T4-S2 spine, the Osteonics® Spinal System Rod/Plate System and Techtonix™ System are indicated for: - Long and short curve scoliosis ● - Vertebral fracture or dislocation . - Spondylolisthesis � - Begenerative disc disease (defined as back pain of discogneic origin with degeneration of . the disc confirmed by history and radiographic studies) - Previously failed fusion . - Spinal tumor ● ### Pedicular Use: - When used as a pedicle screw fixation system of the non-cervical posterior spine in . skeletally mature patients, the Osteonics Spinal System Rod/Plate System and Techtonix "M System are indicated for one or more of the following: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudoarthrosis). - In addition, the Osteonics® Spinal System Rod/Plate System and Techtonix™ System are . indicated for pedicle screw fixation in skeletally mature patients with severe spondylolisthesis (Grades 3 and 4) at the L5-S1 joint, having fusions with autogenous bone graft, having the device fixed or attached to the lumbar and sacral spine (with pedicle placement at L3 and below) with removal of the implants after the development of a solid fusion mass. #### Statement of Technological Comparison: Statement of I cennonents share intended use and basic design concepts as that of the I ne sacreed von. Mechanical testing demonstrated comparable mechanical properties to the predicate devices. ge 2 of 2 {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the Department of Health & Human Services (HHS). The logo consists of a circle with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 FEB 1 6 2005 Ms. Simona Voic Regulatory Affairs Project Manager Stryker Spine 2 Pearl Court Allendale, New Jersey 07401 Re: K050189 Trade/Device Name: Osteonics® Spinal System Rod/Plate System and Techtonix™ System Regulation Number: 21 CFR 888.3050, 888.3070 Regulation Name: Spinal interlaminal fixation orthosis, Pedicle screw spinal system Regulatory Class: II Product Code: MNH, KWP Dated: January 26, 2005 Received: January 27, 2005 Dear Ms. Voic: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ Page 2 - Ms. Simona Voic This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Mark A. Millburn Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Indications for Use 510(k) Number (if known): K Device Name: Osteonics® Spinal System Rod/Plate System and Techtonix™ System Indications For Use: As a posterior, non-pedicle screw system of the T4-S2 spine, the Osteonics Spinal As a posterior, non-podiolo corrent and Techtonix™ System are indicated for: - Long and short curve scoliosis . - Vertebral fracture or dislocation . - Spondylolisthesis . - Degenerative disc disease (defined as back pain of discogneic origin with . Degeneration of the disc confirmed by history and radiographic studies) - Previously failed fusion . - . Spinal tumor #### Pedicular Use: - When used as a pedicle screw fixation system of the non-cervical posterior spine . in skeletally mature patients, the Osteonics® Spinal System Rod/Plate System and Techtonix™ System are indicated for one or more of the following: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudoarthrosis). - previous fusion (postubantikes). In addition, the Osteonics® Spinal System Rod/Plate System and Techtonix™ . in duallen, indicated for pedicle screw fixation in skeletally mature patients with System and manaked is (Grades 3 and 4) at the L5-S1 joint, having fusions with autogenous bone graft, having the device fixed or attached to the lumbar and sacral spine (with pedicle placement at L3 and below) with removal of the implants after the development of a solid fusion mass. AND/OR x Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRED office of Device Evaluation (ODE) *M* (Division Sign-Off) Division of General, Restorative, and Neurological Devices Page 1 of *1* K050189 510(k) Number Page 1 of
Innolitics
510(k) Summary
Decision Summary
Classification Order
Enter a record ID and click Load to view the document.
100%