FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
NDH
Nail, Fixation, Bone, Metallic
2
Product Code
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
3
Product Code
HSA
Prosthesis, Knee, Hemi-, Femoral
3
Product Code
HSB
Rod, Fixation, Intramedullary And Accessories
2
Product Code
NDI
Staple, Fixation, Bone, Metallic
2
Product Code
HRS
Plate, Fixation, Bone
2
Product Code
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
2
Product Code
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
2
Product Code
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
2
Product Code
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
2
Product Code
HTN
Washer, Bolt Nut
2
Product Code
HTY
Pin, Fixation, Smooth
2
Product Code
HWC
Screw, Fixation, Bone
2
Product Code
HXA
Prosthesis, Tendon, Passive
2
Product Code
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
2
Product Code
JDC
Prosthesis, Elbow, Constrained, Cemented
2
Product Code
JDD
Prosthesis, Upper Femoral
2
Product Code
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
2
Product Code
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
3
Product Code
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
2
Product Code
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
3
Product Code
JDN
Implant, Fixation Device, Spinal
2
Product Code
JDO
Device, Fixation, Proximal Femoral, Implant
2
Product Code
JDP
Condylar Plate Fixation Implant
2
Product Code
JDQ
Cerclage, Fixation
2
Product Code
JDR
Staple, Fixation, Bone
2
Product Code
JDS
Nail, Fixation, Bone
2
Product Code
JDT
Cap, Bone
1
Product Code
JDW
Pin, Fixation, Threaded
2
Product Code
JEC
Component, Traction, Invasive
2
Product Code
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
2
Product Code
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
2
Product Code
KIG
Prosthesis, Wrist, Constrained, Polymer
2
Product Code
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
2
Product Code
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
2
Product Code
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
3
Product Code
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
2
Product Code
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
3
Product Code
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
3
Product Code
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
2
Product Code
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
2
Product Code
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
2
Product Code
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
3
Product Code
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
3
Product Code
KWD
Prosthesis, Toe, Hemi-, Phalangeal
2
Product Code
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
3
Product Code
KWF
Prosthesis, Finger, Polymer
2
Product Code
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
3
Product Code
KWH
Prosthesis, Toe, Constrained, Polymer
2
Product Code
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
2
Product Code
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
3
Product Code
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
2
Product Code
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
2
Product Code
KWM
Prosthesis, Wrist, Semi-Constrained
2
Product Code
KWN
Prosthesis, Wrist, Carpal Lunate
2
Product Code
KWO
Prosthesis, Wrist, Carpal Scaphoid
2
Product Code
KWP
Appliance, Fixation, Spinal Interlaminal
2
Product Code
K
14
3278
LnK Posterior Cervical Fixation System
2
Cleared 510(K)
K
15
0753
OASYS System
2
Cleared 510(K)
K
15
0851
Sure Lok Mini Posterior Cervical/Upper Thoracic System
2
Cleared 510(K)
K
14
2867
Reliance Posterior Cervical-Thoracic System
2
Cleared 510(K)
K
15
0254
Streamline OCT Occipito-Cervico-Thoracic System
2
Cleared 510(K)
K
14
2253
SOLSTICE OCT System
2
Cleared 510(K)
K
15
0229
SOLSTICE OCT System
2
Cleared 510(K)
K
14
3249
SOLSTICE OCT System
2
Cleared 510(K)
K
14
2741
OASYS System
2
Cleared 510(K)
K
14
2558
Caspian OCT/MESA Mini/DENALI Mini Spinal System
2
Cleared 510(K)
K
14
0734
NEXTGEN ALTIUS OCT SYSTEM
2
Cleared 510(K)
K
14
2460
EXPEDIUM Spine System/Synapse System
2
Cleared 510(K)
K
14
1897
SYNAPSE SYSTEM, SYNTHES OC FUSION SYSTEM
2
Cleared 510(K)
K
14
1284
CASPIAN SPINAL SYSTEM
2
Cleared 510(K)
K
13
3288
CASPIAN OCT SPINAL SYSTEM
2
Cleared 510(K)
K
13
3556
VIRAGE OCT SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
14
0645
GIBRALT ROD-TO-ROD CROSS CONNECTORS
2
Cleared 510(K)
K
13
3374
STREAMLINE OCT OCCIPITO-CERVICO-THORACIC SYSTEM
2
Cleared 510(K)
K
13
3214
BLACKBIRD SPINAL SYSTEM
2
Cleared 510(K)
K
13
1833
CENTURION POCT SYSTEM
2
Cleared 510(K)
K
13
2122
KESTREL POSTERIOR CERVICAL SPINE SYSTEM
2
Cleared 510(K)
K
13
3698
SYNAPSE SYSTEM
2
Cleared 510(K)
K
13
3094
CERTEX OCT SPINAL IMPLANT SYSTEM
2
Cleared 510(K)
K
13
2504
TIGER OCCIPITAL-CERVICAL-THORACIC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
13
2900
MARAUDER CERVICAL-THORACIC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
13
1427
LOTUS
2
Cleared 510(K)
K
13
2332
MOUNTAINEER OCT SPINAL SYSTEM
2
Cleared 510(K)
K
13
1156
LANX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
12
3906
VERTEX RECONSTRUCTION SYSTEM, VERTEXT SELECT RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
12
1979
PASS OCT SPINAL SYSTEM
2
Cleared 510(K)
K
12
3783
ELLIPSE OCCIPITO-CERICO-THORACIC SPINAL SYSTEM AND CAPITOL IMPLANTS
2
Cleared 510(K)
K
12
3656
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
12
1877
GIBRALT OCCIPITAL PLATE SCREWS, SET SCREW, GIBRALT OCCIPITAL SYSTEM ARTICULATING ROD, GIBRALT OCCIPITAL PLATES
2
Cleared 510(K)
K
12
3232
SPINEOLOGY SPINOUS PROCESS PLATE
2
Cleared 510(K)
K
12
3093
STABILINK MIS SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
12
3568
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
12
2509
VERTIFLEX SPINOUS PROCESS FIXATION PLATE
2
Cleared 510(K)
K
12
1725
PIONEER POSTERIOR OCCIPITO-CERVICO-THORACIC (OCT) SYSTEM
2
Cleared 510(K)
K
12
2292
RELIANCE POSTERIOR CERVICAL- THORACIC SYSTEM
2
Cleared 510(K)
K
12
0998
SOLSTICE CROSS CONNECTOR
2
Cleared 510(K)
K
12
2378
NEXTGEN ALTIUS OCT SYSTEM
2
Cleared 510(K)
K
12
1136
RENOIR POSTERIOR CERVIAL FIXATION SYSTEM
2
Cleared 510(K)
K
12
1808
CASIAN, 3.5/4.5 CONNECTORS
2
Cleared 510(K)
K
12
1115
M.U.S.T PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
12
1191
VERTEX RCCONSTRUCTION SYSTEM
2
Cleared 510(K)
K
11
3593
NEXTGEN ALTIUS OCT SYSTEM
2
Cleared 510(K)
K
11
3324
REXIOUS HOOK FIXATION SYSTEMS
2
Cleared 510(K)
K
11
2757
PIONEER POSTERIOR CERVICO THORACIC SYSTEM
2
Cleared 510(K)
K
11
3346
NEON SYSTEM
2
Cleared 510(K)
K
11
2595
COFLEX-F
2
Cleared 510(K)
K
11
1719
OASYS SPINAL SYSTEM
2
Cleared 510(K)
K
11
3654
CASPIAN
2
Cleared 510(K)
K
11
2592
AXLE PEEK INTERSPINOUS FUSION SYSTEM
2
Cleared 510(K)
K
11
2025
SURE LOK MINI POSTERIOR CERVICAL/UPPER THORACIC SYSTEM
2
Cleared 510(K)
K
10
3205
BRIDGEPOINT SPINOUS PROCESS CAMP- POSTERIOR FIXATION SYSTEM
2
Cleared 510(K)
K
11
1183
ASCENT POSTERIOR OCCIPITAL THORACIC (POCT) SYSTEM (TITANIUM & COBALT CHROME RODS)
2
Cleared 510(K)
K
11
0963
ELLIPSE OCCIPITO-CERVICO-THORACIC SPINAL SYSTEM
2
Cleared 510(K)
K
10
3091
LANX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
11
0353
MOUNTAINEER OCT SPINAL SYSTEM
2
Cleared 510(K)
K
11
0522
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
11
0367
PIONEER SPINAL PROCESS FUSION PLATE
2
Cleared 510(K)
K
10
2886
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
10
2195
SP-FIX SPINOUS PROCESS FIXATION PLATE
2
Cleared 510(K)
K
10
3232
CASPIAN SPINAL SYSTEM
2
Cleared 510(K)
K
10
1471
AXLE INTERSPINOUS FUSION SYSTEM
2
Cleared 510(K)
K
10
0888
MODIFICATION TO LANX POSTERIOR CERVICOTHORACIC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
1183
MODIFICATION TO: OASYS SYSTEM
2
Cleared 510(K)
K
10
1112
RELIANCE SPINAL SCREW SYSTEM
2
Cleared 510(K)
K
10
1525
PIONEER SPINOUS PROCESS FUSION PLATE
2
Cleared 510(K)
K
09
3438
PARADIGM INTERSPINOUS FUSION PLATE
2
Cleared 510(K)
K
10
1084
CASPIAN SPINAL SYSTEM
2
Cleared 510(K)
K
10
2020
VEGA SPAN SPINOUS PROCESS PLATE SYSTEM
2
Cleared 510(K)
K
10
0354
PRIMAL OK INTERSPINOUS FUSION SYSTEM
2
Cleared 510(K)
K
09
3319
NUVASIVE VUEPOINT OCT SYSTEM
2
Cleared 510(K)
K
10
0685
ZODIAC POLYAXIAL SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
0191
LANX POSTERIOR CERVICOTHORACIC SPINAL FIXATION SYSTEM (PCFS)
2
Cleared 510(K)
K
09
2825
APEX SPINE SYSTEM 5.50 MM TITANIUM ROD & POLYAXIAL SCREW WASHER
2
Cleared 510(K)
K
09
2295
PIONEER POSTERIOR CERVICO-THORACIC SYSTEM
2
Cleared 510(K)
K
09
3534
MODIFICATION TO CASPIAN SPINAL SYSTEM
2
Cleared 510(K)
K
09
2656
LANX POSTERIOR CERVICOTHORACIC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
09
1359
GSO PCT SPINAL SYSTEM
2
Cleared 510(K)
K
09
0343
SENTINEL SPINAL SYSTEM
2
Cleared 510(K)
K
09
1365
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
09
1689
SYNAPSE SYSTEM 4.0MM, OC FUSION SYSTEM 4.0MM
2
Cleared 510(K)
K
09
0565
ELLIPSE OCCIPITO-CERICO-THORACIC SPINAL SYSTEM
2
Cleared 510(K)
K
09
0060
NEXLINK OCT SYSTEM, MODEL 7000 SERIES
2
Cleared 510(K)
K
09
0549
SYNTHES SYNAPSE TRANSCONNECTOR
2
Cleared 510(K)
K
09
0714
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
09
0252
MODIFICATION TO: LANX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
08
2728
VERTEX RECONTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
08
2769
MESA AND RANGE SPINAL SYSTEMS
2
Cleared 510(K)
K
08
3071
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
08
1906
PROTEX CT CERVICOTHORACIC SPINAL SYSTEM
2
Cleared 510(K)
K
08
1107
CASPIAN SPINAL SYSTEM, SCREWS, RODS, HOOKS, ROD CONNECTORS
2
Cleared 510(K)
K
08
1297
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
08
0790
MODIFICATION TO THEKEN ATOLL CERVICO-THORACIC SYSTEM
2
Cleared 510(K)
K
08
0805
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
07
2729
SIERRA
2
Cleared 510(K)
K
08
0526
SIERRA SYSTEM
2
Cleared 510(K)
K
07
3278
SPINOUS PROCESS PLATE SYSTEM
2
Cleared 510(K)
K
08
0394
BLACKSTONE ASCENT POSTERIOR OCCIPITAL CERVICO-THORACIC (POCT) SYSTEM
2
Cleared 510(K)
K
07
3420
BLACKSTONE ASCENT MULTIAXIAL SCREWS
2
Cleared 510(K)
K
07
3654
BLACKSTONE ASCENT POCT SYSTEM PARALLEL ROD CONNECTOR
2
Cleared 510(K)
K
07
2866
ISSYS LP SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
07
1942
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
07
2081
ZODIAC DYNAMO SEMI-RIGID SPINAL SYSTEM
2
Cleared 510(K)
K
06
2447
TRAVERSE OCT SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
07
2568
MODIFICATION TO OASYS SYSTEM
2
Cleared 510(K)
K
07
0742
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
07
1633
LANX DEFORMITY SYSTEM
2
Cleared 510(K)
K
07
0341
LDR SPINE EASYSPINE POSTERIOR OSTEOSYNTHESIS SYSTEM
2
Cleared 510(K)
K
07
1377
POLARIS BE RODS
2
Cleared 510(K)
K
07
0966
GSO GS1 SPINAL SYSTEM
2
Cleared 510(K)
K
07
0638
THEKEN ATOLL CERVICO-THORACIC SYSTEM
2
Cleared 510(K)
K
06
1943
ANATOMICA POSTERIOR CERVICAL FIXATION SYSTEM
2
Cleared 510(K)
K
07
0300
EXPEDIUM SFX CROSS CONNECTOR SYSTEM
2
Cleared 510(K)
K
06
2181
C-JAWS CERVICAL COMPRESSIVE MINI FRAME
2
Cleared 510(K)
K
06
2785
LTD POLYAXIAL FIXATION SYSTEM
2
Cleared 510(K)
K
06
2513
APEX SPINE SYSTEM
2
Cleared 510(K)
K
06
1591
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
05
3418
SYNTHES OC FUSION SYSTEM
2
Cleared 510(K)
K
06
1579
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
05
2404
DENALI DEFORMITY SYSTEM
2
Cleared 510(K)
K
06
0683
ENDIUS MINIT POSTERIOR CERVICAL AND UPPER THORACIC FIXATION SYSTEM
2
Cleared 510(K)
K
06
0513
SINTEA BIOTECH PLS MULTI-AXIAL SCREWS, MODEL PLS.XX.T5.X
2
Cleared 510(K)
K
06
0081
BASIS SPINAL SYSTEM
2
Cleared 510(K)
K
05
2201
SOLANAS POSTERIOR STABILIZATION SYSTEM
2
Cleared 510(K)
K
05
2734
MODIFICATION TO: VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
05
2131
EXPEDIUM SPINE SYSTEM 5.5MM COMMERICALLY PURE TITANIUM SPINAL RODS
2
Cleared 510(K)
K
05
2402
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
05
2376
MODIFICATION TO: VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
05
2123
SYNTHES PANGEA SYSTEM
2
Cleared 510(K)
K
05
2247
NEX-LINK SPINAL FIXATION SYSTEM VARIABLE CROSSLINK, MODEL 721-XX
2
Cleared 510(K)
K
05
2181
MODIFICATION TO XIA SPINAL SYSTEM
2
Cleared 510(K)
K
05
1716
VERTEBRON PSS PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
05
2180
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
05
1973
MODIFICATION TO: XIA STAINLESS STEEL SYSTEM
2
Cleared 510(K)
K
05
2069
PROTEX STABILIZATION SYSTEM WITH ADDITIONAL COMPONENTES
2
Cleared 510(K)
K
05
1942
MALIBU SPINAL SYSTEM
2
Cleared 510(K)
K
05
0391
PROTEX CT CERVICOTHORACIC SPINAL SYSTEM
2
Cleared 510(K)
K
05
0830
ZODIAC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
05
0809
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
05
0484
BASIS SPINAL SYSTEM
2
Cleared 510(K)
K
04
3053
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
05
0189
TECHTONIX SYSTEM
2
Cleared 510(K)
K
05
0079
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
04
3522
ISSYS PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
04
3473
MODIFICATION TO XIA SPINAL SYSTEM
2
Cleared 510(K)
K
04
2635
DENALI SPINE SYSTEM
2
Cleared 510(K)
K
04
3020
GLAXY 3.2 SPINAL SYSTEM
2
Cleared 510(K)
K
04
3229
MODIFICATION TO ALTIUS OCT SYSTEM
2
Cleared 510(K)
K
04
2789
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
04
3355
SINTEA BIOTECH POSTERIOR LUMBAR SYSTEM WITH POLYAXIAL AND RECOVERY SCREWS, MODEL PLS.01.T5.X
2
Cleared 510(K)
K
04
2673
ZODIAC POLYAXIAL SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
04
2524
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
04
2508
SUMIT OCT SPINAL SYSTEM AND MOUNTAINEER OCT SPINAL SYSTEM
2
Cleared 510(K)
K
04
2498
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
04
2143
EXCELLA-M SPINAL SYSTEM
2
Cleared 510(K)
K
04
2402
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
04
1808
ENDIUS TITLE 2 POLYAXIAL SPINAL SYSTEM
2
Cleared 510(K)
K
04
1925
ST360 SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
04
1592
CORAL SPINAL SYSTEM
2
Cleared 510(K)
K
04
1862
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
04
1119
EXPEDIUM SPINE SYSTEM
2
Cleared 510(K)
K
04
1449
SYNERGY HELICAL FLANGE PLUG, HELICAL FLANGE SEAT AND HELICAL FLANGE REDUCTION SEAT
2
Cleared 510(K)
K
04
0096
SPINAL CONCEPTS, INC. TANDEM SPINOUS PROCESS PLATE SYSTEM
2
Cleared 510(K)
K
04
1282
MODIFICATION TO TSRH SPINAL SYSTEM
2
Cleared 510(K)
K
03
3961
ALTIUS OCT SYSTEM
2
Cleared 510(K)
K
03
3090
ICON POLYAXIAL PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
03
3980
BLACKSTONE ASCENT POCT SYSTEM HOOKS (SYSTEM MODIFICATION)
2
Cleared 510(K)
K
03
2094
PASSMED SPINAL SYSTEM
2
Cleared 510(K)
K
03
1175
CLICK'X MONOAXIAL SCREWS AND HOOKS
2
Cleared 510(K)
K
03
1471
ORIA SPINAL CLIP SYSTEM, LATERAL INTERMEDIATE CONNECTOR, MODEL AL01
2
Cleared 510(K)
K
03
1772
TI FENESTRATED PLATE
2
Cleared 510(K)
K
02
3884
MODIFICATION ORIA SPINAL SYSTEM
2
Cleared 510(K)
K
03
1893
XIA SPINAL SYSTEM AND XIA STAINLESS STEEL SYSTEM
2
Cleared 510(K)
K
03
1595
U & I AMERICA SPINAL HOOK SYSTEM
2
Cleared 510(K)
K
03
0875
MODIFICATION TO COLORADO 2 SPINAL SYSTEM
2
Cleared 510(K)
K
03
1452
ORIA SPINAL CLIP SYSTEM, SACRAL CONNECTOR, MODELS CA03 AND AO03
2
Cleared 510(K)
K
03
1533
VANTAGE ANTERIOR FIXATION SYSTEM
2
Cleared 510(K)
K
03
0197
BLACKSTONE POSTERIOR CERVICAL SYSTEM
2
Cleared 510(K)
K
03
0816
MSD CABLE REDUCTION SYSTEM
2
Cleared 510(K)
K
03
1090
MODIFICATION TO XIA STAINLESS STEEL SYSTEM
2
Cleared 510(K)
K
03
0252
ORIA SPINAL CLIP SYSTEM EXTENDED OMNIAXIAL CONNECTORS (CO05 & CO07)
2
Cleared 510(K)
K
03
0253
ORIA SPINAL CLIP SYSTEM, LENGTHENED LATERAL CONNECTOR, MODEL AL06
2
Cleared 510(K)
K
03
0241
MODIFICATION TO BLACKSTONE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
3804
MOSS MIAMI SPINAL SYSTEM PIN NUT
2
Cleared 510(K)
K
02
3797
LAURAIN DEWALD ANTERIOR FIXATION SYSTEM
2
Cleared 510(K)
K
02
3415
MODIFICATION TO DYNALOK CLASSIC SPINAL SYSTEM
2
Cleared 510(K)
K
01
4296
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
02
2048
INTERPORE CROSS INTERNATIONAL (ICI) OCCIPITO-CERVICO-THORACIC (OCT) ROD AND PLATE SYSTEM
2
Cleared 510(K)
K
02
3675
SYNTHES CERVIFIX/ AXON
2
Cleared 510(K)
K
02
3555
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
02
1679
ORIA SPINAL CLIP SYSTEM
2
Cleared 510(K)
K
02
3498
MODIFICATION TO BLACKSTONE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
2374
CADENCE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
2191
MODIFICATION TO TENOR SPINAL SYSTEM
2
Cleared 510(K)
K
02
2623
5.0 MM DIAMETER POLYAXIAL SCREWS (MOSS MIAMI 6.35MM SYSTEM)
2
Cleared 510(K)
K
02
1507
PLUS PIVOT LINK UNIVERSAL SYSTEM
2
Cleared 510(K)
K
02
1061
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
02
2070
XANTUS ANTERIOR LATERAL SUPPLEMENTAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
2015
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
02
1170
TSRH SPINAL SYSTEM
2
Cleared 510(K)
K
02
1919
SCS CLARIS SPINAL SYSTEM,REXTENDED OMNIAXIAL CONNECTOR-,MEDIUM, MODEL CO05, SCS CLARIS SPINAL SYSTEM,EXTENDED OMNIAXIALO
2
Cleared 510(K)
K
02
1825
MODIFICATION TO SPIRAL RADIUS 90-D SST SYSTEM
2
Cleared 510(K)
K
02
1009
OCTAFIX OCCIPITAL CERVICAL PLATING SYSTEM
2
Cleared 510(K)
K
02
0709
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
02
0134
SPIRAL RADIUS 90-D RODDING SYSTEM
2
Cleared 510(K)
K
01
4090
ENDIUS SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
0426
MSD WIRE SYSTEM
2
Cleared 510(K)
K
02
0236
MODIFICATION TO PASS SPINAL SYSTEM
2
Cleared 510(K)
K
01
3312
P.L.U.S. SYSTEM (PIVOT LINK UNIVERSAL SYSTEM)
2
Cleared 510(K)
K
02
0155
DYNA-LOK CLASSIC SPINAL SYSTEM
2
Cleared 510(K)
K
01
3196
ASCEND SPINAL FIXATION SYSTEM WITH THE SHADOW SPINAL SYSTEM
2
Cleared 510(K)
K
01
4267
BUTTERFLY PLATE FIXATION SYSTEM
2
Cleared 510(K)
K
01
3447
ISOBAR SPINAL SYSTEM
2
Cleared 510(K)
K
01
3442
PASS SPINAL SYSTEM
2
Cleared 510(K)
K
01
3823
XIA SPINAL SYSTEM
2
Cleared 510(K)
K
01
2516
EBI SPINELINK - II SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
01
3441
ISOLA POLYAXIAL WASHER
2
Cleared 510(K)
K
01
2173
DEVICE MODIFICATION OF SILHOUETTE SPINDAL FIXATION SYSTEM
2
Cleared 510(K)
K
00
3780
VERTEX RECONSTRUCTION SYSTEM
2
Cleared 510(K)
K
01
2870
XIA STAINLESS STEEL SYSTEM
2
Cleared 510(K)
K
01
2871
SYNERGY TI INTEGRAL OPEN SCREWS MODELS # 6193, 6194, 6195,6196, 6173, 6174, 6175, 6176, 6177
2
Cleared 510(K)
K
01
1830
TRI-FIX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
01
1969
SYNTHES CERVIFIX SYSTEM
2
Cleared 510(K)
K
01
0681
SUMMIT OCCIPITO-CERVICO-THORACIC (OCT) SPINAL SYSTEM
2
Cleared 510(K)
K
00
3823
SCS DT-02 TRANSVERSE CONNECTOR
2
Cleared 510(K)
K
01
1508
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
01
0181
CD HORIZON SPINAL SYSTEM, 4.5 ROD FOR POSTERIOR APPLICATION
2
Cleared 510(K)
K
01
0632
BUTTERFLY PLATE FUNCTION SYSTEM
2
Cleared 510(K)
K
01
0515
MODIFICATION TO SYNERGY SPINAL SYSTEM
2
Cleared 510(K)
K
00
1535
ZENITH PLATE SYSTEM, ANTERIOR SPINAL INSTRUMENTATION
2
Cleared 510(K)
K
00
3911
TERRAY STAINLESS STEEL ROD (STRAIGHT, L, RECTANGLE)
2
Cleared 510(K)
K
00
3351
PARSFIX CABLE-SCREW SYSTEM
2
Cleared 510(K)
K
00
3822
ISOLA CLOSED DUAL ROD CONNECTOR
2
Cleared 510(K)
K
00
2733
SUMMIT OCCIPITO-CERVICO-THORACIC (OCT) SPINAL SYSTEM
2
Cleared 510(K)
K
00
2059
AMT SPINAL SYSTEM
2
Cleared 510(K)
K
00
2103
SIMPLICITY SPINAL SYSTEM
2
Cleared 510(K)
K
00
2959
MODIFICATION TO ISOBAR SPINAL SYSTEM
2
Cleared 510(K)
K
00
2082
SPEEDLINK TRANSVERSE CONNECTOR
2
Cleared 510(K)
K
00
2505
XIA SPINE SYSTEM
2
Cleared 510(K)
K
00
2069
ASCEND SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
00
2607
MOSS MIAMI 6.35MM ROD SYSTEM MONOAXIAL SCREWS, POLYAXIAL REDUCTION SCREWS AND SACRAL EXTENDERS
2
Cleared 510(K)
K
00
2517
USS VAS
2
Cleared 510(K)
K
00
1653
XIA SPINE SYSTEM SACRAL BLOCK ASSEMBLY
2
Cleared 510(K)
K
00
1470
E-Z LINK CROSS CONNECTOR
2
Cleared 510(K)
K
00
1372
E-Z LINK CROSS CONNECTOR
2
Cleared 510(K)
K
00
1080
SPINE SYSTEM EVOLUTION
2
Cleared 510(K)
K
00
1532
DYNA-LOK CLASSIC SPINAL SYSTEM
2
Cleared 510(K)
K
00
1105
MOSS MIAMI 6.35MM ROD SYSTEM PEDICLE AND LAMINAR HOOKS
2
Cleared 510(K)
K
99
4187
SYNTHES CERVIFIX SYSTEM
2
Cleared 510(K)
K
99
2885
VERSALOK LOW BACK FIXATION SYSTEM
2
Cleared 510(K)
K
99
3067
SILHOUETTE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
99
1662
TITANIUM HARTSHILL SYSTEM
2
Cleared 510(K)
K
99
0986
CONTOUR SPINAL SYSTEM
2
Cleared 510(K)
K
99
1198
DYNA-LOK PLUS SPINAL SYSTEM
2
Cleared 510(K)
K
99
1089
SYNTHES CERVIFIX SYSTEM
2
Cleared 510(K)
K
99
1586
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
2
Cleared 510(K)
K
99
0965
SYNTHES CERVIFIX SYSTEM
2
Cleared 510(K)
K
99
0922
OSTEONICS SPINAL SYSTEM VERSATILE CROSS CONNECTOR
2
Cleared 510(K)
K
98
4375
OSTEONICS SPINAL SYSTEM - SACRAL OFFSET CONNECTOR ASSEMBLY
2
Cleared 510(K)
K
99
0303
EBI OMEGA 21 SYSTEM
2
Cleared 510(K)
K
99
0845
MODIFICATION TO PARTS NUMBERED CGT-SL AND CGT-SL-15
2
Cleared 510(K)
K
99
0708
TITANIUM VERSALOK
2
Cleared 510(K)
K
98
1676
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
98
4377
SYNTHES SPINE CERVIFIX SYSTEM
2
Cleared 510(K)
K
98
3904
ROGOZINSKI SPINAL ROD SYSTEM
2
Cleared 510(K)
K
98
3353
SCS SPINAL SYSTEM
2
Cleared 510(K)
K
98
3530
SYNTHES POSTERIOR UNIVERSAL SPINAL SYSTEM
2
Cleared 510(K)
K
98
3583
DEPUY ACROMED MOSS AND MOSS MIAMI SPINAL SYSTEMS
2
Cleared 510(K)
K
98
2322
SYNTHES SPINE OCCIPITAL-CERVICAL PLATE/ROD AND HOOK SYSTEM
2
Cleared 510(K)
K
98
3282
OMI OCCIPITAL CERVICAL LOOP, MODEL A1089
2
Cleared 510(K)
K
98
3706
MODIFICATION OF TOWNLEY PEDICLE SCREW PLATING SYSTEM
2
Cleared 510(K)
K
98
3197
SURGICAL DYNAMICS RODDING SYSTEM (PREVIOUSLY KNOWN AS THE AURORA TITANIUM SPINAL ROD SYSTEM)
2
Cleared 510(K)
K
98
2490
TENOR SPINAL SYSTEM
2
Cleared 510(K)
K
98
2511
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEMS
2
Cleared 510(K)
K
98
2320
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
98
2494
BWM SPINE SYSTEM
2
Cleared 510(K)
K
98
2908
MODIFICATION TO EBI SPINELINK SYSTEM
2
Cleared 510(K)
K
98
2011
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
98
0288
SPINE-TECH SILHOUETTE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
98
0121
AESCULAP SPINE SYSTEM ADDITIONAL COMPONENTS
2
Cleared 510(K)
K
98
1452
OSTEONICS LONG ARM CONTAINMENT RING
2
Cleared 510(K)
K
98
0928
SYNTHES SPINE UNIVERSAL SPINAL HOOK, ROD, PEDICLE/SACRAL SCREW FIXATION SYSTEM
2
Cleared 510(K)
K
98
0358
SYNTHES SPINE POSTERIOR CERVICAL/THORACIC HOOK/ROD SYSTEM
2
Cleared 510(K)
K
97
4573
DEPUY MOTECH MOSS-MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
97
3868
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
2
Cleared 510(K)
K
96
4159
CD SPINAL SYSTEM
2
Cleared 510(K)
K
96
5221
RANSFORD CERVICAL FIXATION SYSTEM
2
Cleared 510(K)
K
97
1457
BRYAN POSTERIOR SPINAL FIXATOR (BPSF), MODIFIED
2
Cleared 510(K)
K
97
1289
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
2
Cleared 510(K)
K
96
5224
EMPOWER ANTERIOR DIRECT SCREWS
2
Cleared 510(K)
K
96
4254
TITANIUM LIBERTY POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
96
4404
BACFIX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
96
4024
DEPUY MOTECH TITANIUM MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
96
2628
MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
96
5145
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
96
2708
TITANIUM CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
96
0444
FINN ROD TO ROD CONNECTOR
2
Cleared 510(K)
K
96
4275
ALPHA POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
96
2314
HALIFAX PLUS INTERLAMINAR CLAMP SYSTEM
2
Cleared 510(K)
K
96
1633
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
96
2984
ISOLA PEDIATRIC COMPONENTS
2
Cleared 510(K)
K
96
3639
ACROMED PEDICLE SCREW
2
Cleared 510(K)
K
95
5807
COTREL-DUBOUSSET (CD) SPINAL
2
Cleared 510(K)
K
95
5365
COMPACT COTREL-DUBOUSSET (CCD) SPINAL SYSTEM
2
Cleared 510(K)
K
95
5864
J.B. S. C1-C2 CLAMP
2
Cleared 510(K)
K
95
5927
BRYAN POSTERIOR SPINAL FIXATOR (MODIFICATION)
2
Cleared 510(K)
K
95
4696
ROGOZINSKI THORACOLUMBAR SPINAL ROD
2
Cleared 510(K)
K
95
5348
TITANIUM MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
95
1846
MIRAGE SPINAL SYSTEM FOR SEVERE SPONDYLOLISTHESIS
2
Cleared 510(K)
K
95
5173
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
2
Cleared 510(K)
K
95
1164
CD LIBERTY POSTERIOR SPINCAL SYSTEM
2
Cleared 510(K)
K
95
4770
CENTRA-LINE GRAPPLE, VARIFIX SYSTEM
2
Cleared 510(K)
K
95
4645
TITANIUM GDLH POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
95
3599
CLAMP ASSEMBLY
2
Cleared 510(K)
K
93
6294
SENTRY(TM) ANTERIOR/POSTERIOR SPINAL SYSTEMS
2
Cleared 510(K)
K
94
2432
J.B.S. CERVICAL SPINE SYSTEM
2
Cleared 510(K)
K
94
5781
WEBB-MORLEY SPINE SYSTEM
2
Cleared 510(K)
K
94
5435
BRYAN POSTERIOR SPINAL FIXATOR (BPSF)
2
Cleared 510(K)
K
94
5022
APOFIX CERVICAL SPINE FIXATION
2
Cleared 510(K)
K
93
1381
AME UNIVERSAL FIXATION SYSTEM
2
Cleared 510(K)
K
93
5113
J.B.S. IMPLANTABLE SPINAL FIXATION DEVICE
2
Cleared 510(K)
K
93
0009
STRYKER 2S SPINAL SYSTEM
2
Cleared 510(K)
K
93
3881
DEPUY MOTECH MOSS-MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
93
0657
D-C-S SYSTEM
2
Cleared 510(K)
K
93
0515
ALPHA SPINAL SYSTEM
2
Cleared 510(K)
K
93
4582
GDLH VARIABLE ANGLE CONNECTOR
2
Cleared 510(K)
K
93
4860
TI-FRAME
2
Cleared 510(K)
K
93
4007
SOFAMOR ORFIL SPINE FIXATION SYSTEM
2
Cleared 510(K)
K
93
3205
TSRH(R) TOP TIGHT T-BOLT-VARI ANGLE/SCREW/PARAGON
2
Cleared 510(K)
K
93
1225
LOW PROFILE MID CROSS BRACING
2
Cleared 510(K)
K
93
0891
SYNTHES (USA) UNIV SPINE ROD/SACRAL SCREW FIX SYST
2
Cleared 510(K)
K
93
1208
LOW PROFILE SLEAVE NUT ASSEMBLY
2
Cleared 510(K)
K
91
4548
BRYAN SPINAL FIXATER (BSF)
2
Cleared 510(K)
K
93
0531
AME(R) RIGID FIXATION SYSTEM
2
Cleared 510(K)
K
93
0710
SENTRY POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
92
4474
SELBY INSTRUMENTATION
2
Cleared 510(K)
K
92
1056
COTREL - DUBOUSSET SPINE IMPLANTS
2
Cleared 510(K)
K
92
1948
SYNTHES UNIVERSAL SPINE HOOK AND ROD FIXATION SYST
2
Cleared 510(K)
K
92
1767
COMPACT COTREL -- DUBOUSSET SPINE SYSTEM
2
Cleared 510(K)
K
92
4142
CODMAN(TM) TITANIUM INTERLAMINAR CLAMP KIT
2
Cleared 510(K)
K
91
5672
EDWARDS ADJUSTABLE CONNECTORS
2
Cleared 510(K)
K
92
4381
PWB LUMBAR LAMINAR HOOKS WITH SET SCREWS
2
Cleared 510(K)
K
92
5811
TSRH CENTRAL POST HOOKS
2
Cleared 510(K)
K
92
2672
AUGMENT POSTERIOR SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
92
2504
ISOLA(R) TANDEM CONNECTOR
2
Cleared 510(K)
K
92
1256
LUQUE V SPINAL SYSTEM
2
Cleared 510(K)
K
92
0546
PARAGON POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
92
1090
ISOLA(R) TRANSVERSE ROD DUAL CONNECTOR
2
Cleared 510(K)
K
92
0392
ISOLA SPINE SYSTEM: PLATE-ROD COMBINATION
2
Cleared 510(K)
K
92
2238
LEAPLAZA FRAME
2
Cleared 510(K)
K
92
2520
MODIFIED TSRH CENTRAL POST HOOKS
2
Cleared 510(K)
K
92
3339
TSRH L CONNECTOR -- MODIFICATION
2
Cleared 510(K)
K
91
2837
MCAFEE SPINAL SYSTEM FOR POSTERIOR APPLICATIONS
2
Cleared 510(K)
K
91
4306
TSRH(TM) LATERAL OFFSET PLATE
2
Cleared 510(K)
K
91
4966
TSRH CENTRAL POST HOOKS
2
Cleared 510(K)
K
92
0102
THE SELBY SYSTEM
2
Cleared 510(K)
K
92
0116
PWB LUMBOSACRAL SPINE SYSTEM
2
Cleared 510(K)
K
91
1663
CROSSLINK SYSTEM
2
Cleared 510(K)
K
90
4243
TSRH VARIABLE ANGLE SACRAL SCREW
2
Cleared 510(K)
K
91
3561
LUQUE SEGMENTAL SPINAL INSTRUMENTATION
2
Cleared 510(K)
K
91
4269
EDWARDS ANATO HOOK/UNIV ROD/WASH/SACR SCREW/ADJ CO
2
Cleared 510(K)
K
90
4520
RAY SACRAL FIXATION SYSTEM
2
Cleared 510(K)
K
91
1307
CROSSLINK PLATE
2
Cleared 510(K)
K
91
1379
DANEK SACRAL HOOK, MODIFICATION
2
Cleared 510(K)
K
91
1319
TSRH OPEN HEAD BONE SCREW
2
Cleared 510(K)
K
91
1528
ISOLA(TM) SPINE SYSTEM - ILIAC SCREW
2
Cleared 510(K)
K
91
1394
ISOLA(TM) SPINE SYSTEM--EYE ROD
2
Cleared 510(K)
K
90
5826
ISOLA SLOTTED CONNECT/ANGLED SLOTTED CONNECTOR
2
Cleared 510(K)
K
90
5184
ISOLA(TM) SPINE SYSTEM TOP ENTRY HOOK
2
Cleared 510(K)
K
90
3376
ACROMED SACRAL SCREW
2
Cleared 510(K)
K
90
2775
KNIGHT SACRAL SCREW
2
Cleared 510(K)
K
90
1005
TSRH SPINAL SYSTEM (ADD'L SIZES OF HOOKS)
2
Cleared 510(K)
K
90
3461
TSRH OFFSET AND SIDE-LOADING HOOKS
2
Cleared 510(K)
K
90
2397
MODULOCK POSTERIOR SPINAL FIXATION
2
Cleared 510(K)
K
90
1587
TSRH SACRAL L-CONNECTOR
2
Cleared 510(K)
K
90
1590
DANEK SACRAL HOOK
2
Cleared 510(K)
K
89
5978
CHIBA SPINAL SYSTEM
2
Cleared 510(K)
K
89
6106
ROGOZINSKI SPINAL SYSTEM, ADD'L COMPONENTS
2
Cleared 510(K)
K
89
6254
DANEK PRECISION ROD SET
2
Cleared 510(K)
K
89
5296
SELBY II INSTRUMENTATION
2
Cleared 510(K)
K
89
6740
AXIAL AND OFFSET CROSSLINK PLATES
2
Cleared 510(K)
K
89
6603
HSC UNIT ROD
2
Cleared 510(K)
K
89
0192
LUQUE III SPINAL SYSTEM AND LUQUE MINI-SET
2
Cleared 510(K)
K
89
5441
ACROMED BUTTON SPINAL WIRE
2
Cleared 510(K)
K
89
5413
ACROMED DOUBLE SUBLAMINAR WIRE
2
Cleared 510(K)
K
89
5439
ACROMED BEADED SUBLAMINAR WIRE
2
Cleared 510(K)
K
89
4702
STUART CD UNIVERSAL ROD CONNECTOR CLAMPS
2
Cleared 510(K)
K
89
4472
CROSS ROUND & SQUARE SPINAL RODS & DIST. SPINAL
2
Cleared 510(K)
K
88
4998
SELBY INSTRUMENTATION
2
Cleared 510(K)
K
88
4690
KIRSCHNER SPINAL FIXATOR KMS-1
2
Cleared 510(K)
K
88
4161
ACROMED ILIAC SCREW
2
Cleared 510(K)
K
88
4163
ACROMED SPINAL ROD AND SPINAL HOOKS
2
Cleared 510(K)
K
89
0187
THE C-S DISTRACTION ROD ASSEMBLY
2
Cleared 510(K)
K
88
3783
TSRH SACRAL SPINAL SCREW
2
Cleared 510(K)
K
88
4688
MODULAR SPINAL FIXATION & LOCKING HOOK SPINAL ROD
2
Cleared 510(K)
K
88
4585
LEA PLAZA SPINAL FRAME SYSTEM
2
Cleared 510(K)
K
88
4263
ROGOZINSKI SPINAL SYSTEM
2
Cleared 510(K)
K
88
2070
LUMBAR IMPACTION SET AND BONE GRAFT IMPACTORS
2
Cleared 510(K)
K
88
2068
COBB SPINAL ELEVATORS
2
Cleared 510(K)
K
88
0212
TSRH H/M HOOK HOLDER W/ROD MOVER
2
Cleared 510(K)
K
88
0211
TSRH H/M HOOK HOLDER
2
Cleared 510(K)
K
87
5290
LUMBAR IMPACTION SET
2
Cleared 510(K)
K
88
0215
TSRH H/M HOOK, EYEBOLT/LOCK NUT ASSEM., SPINAL ROD
2
Cleared 510(K)
K
88
0214
TSRH H/M TORQUE LIMITING WRENCH
2
Cleared 510(K)
K
87
4882
ACROMED CROSS ROD CONNECTOR
2
Cleared 510(K)
K
87
1870
HSC UNIT ROD
2
Cleared 510(K)
K
87
0085
ANTERIOR SPINAL FIXATION PLATE
2
Cleared 510(K)
K
87
0830
WARSAW ORTHOPEDIC TSR CROSS LINK SYSTEM
2
Cleared 510(K)
K
85
4770
MARTIN LAMINAR OSTEOSYNTHESIS SYSTEM
2
Cleared 510(K)
K
85
4524
KIRSCHNER SPINAL PRODUCT SYSTEM
2
Cleared 510(K)
K
85
4313
SONGER TITANIUM SPINE-L-ROD
2
Cleared 510(K)
K
85
1935
EDWARDS SACRAL SCREW
2
Cleared 510(K)
K
85
0039
HALIFAX SPINAL CLAMP
2
Cleared 510(K)
K
84
3445
SACRAL BAR
2
Cleared 510(K)
K
84
3687
ROD FOR RACHIS SURGERY
2
Cleared 510(K)
K
84
0423
HARRINGTON-TYPE INSTRU-SCOLIOSIS
2
Cleared 510(K)
K
82
0660
A HOOK DRIVER
2
Cleared 510(K)
K
81
0329
DEPUY SEGMENTALSPINAL SYSTEM
2
Cleared 510(K)
K
81
0224
ARMSTRONG SPINAL APPLIANCE
2
Cleared 510(K)
K
80
2462
SYNTHES SPINAL IMPLANT SYSTEM
2
Cleared 510(K)
K
80
1120
DUNN ANTERIOR DISTRACTION SYSTEM
2
Cleared 510(K)
K
80
1080
EDWARDS ROD SLEEVES
2
Cleared 510(K)
K
79
1009
SANTA CASA DISTRACTOR
2
Cleared 510(K)
K
79
0465
KNEE COMPRESSION HOOK SYSTEM
2
Cleared 510(K)
K
79
0238
TRANSVERSE TRACTION ASSEMBLY
2
Cleared 510(K)
K
78
1444
OUTRIGGER DISTRACTION UNIT
2
Cleared 510(K)
K
78
1443
HARRINGTON SPINE INSTRUMENTATION
2
Cleared 510(K)
KWQ
Appliance, Fixation, Spinal Intervertebral Body
2
Product Code
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
3
Product Code
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
2
Product Code
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
2
Product Code
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
2
Product Code
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
2
Product Code
KXA
Prosthesis, Hip, Femoral, Resurfacing
2
Product Code
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
3
Product Code
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
3
Product Code
KXD
Prosthesis, Hip, Constrained, Metal
3
Product Code
KXE
Prosthesis, Wrist, Hemi-, Ulnar
2
Product Code
KYI
Prosthesis, Wrist, Carpal Trapezium
2
Product Code
KYJ
Prosthesis, Finger, Constrained, Polymer
2
Product Code
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
3
Product Code
KYN
Prosthesis, Wrist, Constrained, Metal
3
Product Code
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
3
Product Code
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
2
Product Code
LOD
Bone Cement
2
Product Code
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
2
Product Code
LRN
Wire, Surgical
2
Product Code
LTO
Spacer, Cement
3
Product Code
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
2
Product Code
LYP
Accessories, Fixation, Spinal Interlaminal
2
Product Code
LYT
Fixation Accessory
2
Product Code
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
2
Product Code
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
2
Product Code
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
2
Product Code
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
2
Product Code
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
2
Product Code
MBB
Bone Cement, Antibiotic
2
Product Code
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
2
Product Code
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
2
Product Code
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
2
Product Code
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
2
Product Code
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
2
Product Code
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
2
Product Code
MJW
Prosthesis, Subtalar, Plug, Polymer
2
Product Code
MNH
Orthosis, Spondylolisthesis Spinal Fixation
2
Product Code
MNI
Orthosis, Spinal Pedicle Fixation
2
Product Code
MNU
Staple, Absorbable
2
Product Code
MQP
Spinal Vertebral Body Replacement Device
2
Product Code
MQV
Filler, Bone Void, Calcium Compound
2
Product Code
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
2
Product Code
NDD
Cerclage, Fixation, Metallic
2
Product Code
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
2
Product Code
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
2
Product Code
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDK
System, External Fixator (With Metallic Invasive Components)
2
Product Code
NDL
Pin, Fixation, Smooth, Metallic
2
Product Code
NDM
Pin, Fixation, Threaded, Metallic
2
Product Code
NDN
Cement, Bone, Vertebroplasty
2
Product Code
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
2
Product Code
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
2
Product Code
NKB
Thoracolumbosacral Pedicle Screw System
2
Product Code
NKG
Posterior Cervical Screw System
2
Product Code
NOV
Anchor, Suture, Bone Fixation, Metallic
2
Product Code
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
NQP
Posterior Metal/Polymer Spinal System, Fusion
2
Product Code
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
2
Product Code
NUD
Vertebroplasty Compound, Calcium Based
2
Product Code
NVC
Bone, Heterograft
3
Product Code
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
2
Product Code
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
2
Product Code
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
2
Product Code
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
2
Product Code
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
3
Product Code
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
2
Product Code
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
2
Product Code
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
2
Product Code
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
2
Product Code
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
2
Product Code
OOG
Knee Arthroplasty Implantation System
2
Product Code
OOL
Electronic Depth Gauge
2
Product Code
OQB
Intervertebral Body Graft Containment Device
2
Product Code
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
2
Product Code
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
2
Product Code
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
2
Product Code
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
2
Product Code
OSN
Software For Diagnosis/Treatment
2
Product Code
OUR
Sacroiliac Joint Fixation
2
Product Code
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
2
Product Code
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
2
Product Code
OVZ
Pin, Fixation, Resorbable, Hard Tissue
2
Product Code
OWI
Bone Fixation Cerclage, Sublaminar
2
Product Code
OYK
Ankle Arthroplasty Implantation System
2
Product Code
OZI
Internal Hinged Elbow Fixator
2
Product Code
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
2
Product Code
PBF
Orthopaedic Surgical Planning And Instrument Guides
2
Product Code
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
2
Product Code
PEK
Spinous Process Plate
2
Product Code
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
2
Product Code
PHQ
Anterior Staple As Supplemental Fixation For Fusion
2
Product Code
PHX
Shoulder Prosthesis, Reverse Configuration
2
Product Code
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
2
Product Code
PLF
Bone Wedge
2
Product Code
PLR
Spinal Vertebral Body Replacement Device - Cervical
2
Product Code
PLW
Acetabular Cup Orientation System
2
Product Code
PML
Bone Cement, Posterior Screw Augmentation
2
Product Code
PPQ
Transtibial Anterior Cruciate Ligament Kit
2
Product Code
QHQ
Total Shoulder Arthroplasty System
2
Product Code
PQC
Pedicle Screw Placement Guide
2
Product Code
QAC
Screw Sleeve Bone Fixation Device
2
Product Code
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
2
Product Code
QFP
Intraoperative Orthopedic Strain Sensor
2
Product Code
QHE
Shoulder Arthroplasty Implantation System
2
Product Code
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
2
Product Code
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
2
Product Code
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
2
Product Code
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
2
Product Code
JDK
Prosthesis, Hip, Cement Restrictor
2
Product Code
LZN
Cement Obturator
2
Product Code
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
2
Product Code
QSD
Posterior Cervical Screw Placement Guide
2
Product Code
QSR
Sacroiliac Screw Placement Guide
2
Product Code
QVI
Screw Sleeve Bone Fixation Device, Spine
2
Product Code
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
SAI
Ankle Fusion Cage
2
Product Code
SCY
Sacroiliac Joint Guidewire Placement Device
2
Product Code
Subpart E—Neurological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 3 April 2026 at 11:13 pm
OR
/
subpart-d—prosthetic-devices
/
KWP
/
K031893
View Source
XIA SPINAL SYSTEM AND XIA STAINLESS STEEL SYSTEM
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K031893
510(k) Type
Special
Applicant
Howmedica Osteonics Corp.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
7/17/2003
Days to Decision
28 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Miscellaneous
Subpart B—Diagnostic Devices
Subpart D—Prosthetic Devices
NDH
Nail, Fixation, Bone, Metallic
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
HSA
Prosthesis, Knee, Hemi-, Femoral
HSB
Rod, Fixation, Intramedullary And Accessories
NDI
Staple, Fixation, Bone, Metallic
HRS
Plate, Fixation, Bone
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
HTN
Washer, Bolt Nut
HTY
Pin, Fixation, Smooth
HWC
Screw, Fixation, Bone
HXA
Prosthesis, Tendon, Passive
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
JDC
Prosthesis, Elbow, Constrained, Cemented
JDD
Prosthesis, Upper Femoral
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
JDN
Implant, Fixation Device, Spinal
JDO
Device, Fixation, Proximal Femoral, Implant
JDP
Condylar Plate Fixation Implant
JDQ
Cerclage, Fixation
JDR
Staple, Fixation, Bone
JDS
Nail, Fixation, Bone
JDT
Cap, Bone
JDW
Pin, Fixation, Threaded
JEC
Component, Traction, Invasive
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
KIG
Prosthesis, Wrist, Constrained, Polymer
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
KWD
Prosthesis, Toe, Hemi-, Phalangeal
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
KWF
Prosthesis, Finger, Polymer
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
KWH
Prosthesis, Toe, Constrained, Polymer
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
KWM
Prosthesis, Wrist, Semi-Constrained
KWN
Prosthesis, Wrist, Carpal Lunate
KWO
Prosthesis, Wrist, Carpal Scaphoid
KWP
Appliance, Fixation, Spinal Interlaminal
K
14
3278
LnK Posterior Cervical Fixation System
K
15
0753
OASYS System
K
15
0851
Sure Lok Mini Posterior Cervical/Upper Thoracic System
K
14
2867
Reliance Posterior Cervical-Thoracic System
K
15
0254
Streamline OCT Occipito-Cervico-Thoracic System
K
14
2253
SOLSTICE OCT System
K
15
0229
SOLSTICE OCT System
K
14
3249
SOLSTICE OCT System
K
14
2741
OASYS System
K
14
2558
Caspian OCT/MESA Mini/DENALI Mini Spinal System
K
14
0734
NEXTGEN ALTIUS OCT SYSTEM
K
14
2460
EXPEDIUM Spine System/Synapse System
K
14
1897
SYNAPSE SYSTEM, SYNTHES OC FUSION SYSTEM
K
14
1284
CASPIAN SPINAL SYSTEM
K
13
3288
CASPIAN OCT SPINAL SYSTEM
K
13
3556
VIRAGE OCT SPINAL FIXATION SYSTEM
K
14
0645
GIBRALT ROD-TO-ROD CROSS CONNECTORS
K
13
3374
STREAMLINE OCT OCCIPITO-CERVICO-THORACIC SYSTEM
K
13
3214
BLACKBIRD SPINAL SYSTEM
K
13
1833
CENTURION POCT SYSTEM
K
13
2122
KESTREL POSTERIOR CERVICAL SPINE SYSTEM
K
13
3698
SYNAPSE SYSTEM
K
13
3094
CERTEX OCT SPINAL IMPLANT SYSTEM
K
13
2504
TIGER OCCIPITAL-CERVICAL-THORACIC SPINAL FIXATION SYSTEM
K
13
2900
MARAUDER CERVICAL-THORACIC SPINAL FIXATION SYSTEM
K
13
1427
LOTUS
K
13
2332
MOUNTAINEER OCT SPINAL SYSTEM
K
13
1156
LANX SPINAL FIXATION SYSTEM
K
12
3906
VERTEX RECONSTRUCTION SYSTEM, VERTEXT SELECT RECONSTRUCTION SYSTEM
K
12
1979
PASS OCT SPINAL SYSTEM
K
12
3783
ELLIPSE OCCIPITO-CERICO-THORACIC SPINAL SYSTEM AND CAPITOL IMPLANTS
K
12
3656
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
K
12
1877
GIBRALT OCCIPITAL PLATE SCREWS, SET SCREW, GIBRALT OCCIPITAL SYSTEM ARTICULATING ROD, GIBRALT OCCIPITAL PLATES
K
12
3232
SPINEOLOGY SPINOUS PROCESS PLATE
K
12
3093
STABILINK MIS SPINAL FIXATION SYSTEM
K
12
3568
VERTEX RECONSTRUCTION SYSTEM
K
12
2509
VERTIFLEX SPINOUS PROCESS FIXATION PLATE
K
12
1725
PIONEER POSTERIOR OCCIPITO-CERVICO-THORACIC (OCT) SYSTEM
K
12
2292
RELIANCE POSTERIOR CERVICAL- THORACIC SYSTEM
K
12
0998
SOLSTICE CROSS CONNECTOR
K
12
2378
NEXTGEN ALTIUS OCT SYSTEM
K
12
1136
RENOIR POSTERIOR CERVIAL FIXATION SYSTEM
K
12
1808
CASIAN, 3.5/4.5 CONNECTORS
K
12
1115
M.U.S.T PEDICLE SCREW SYSTEM
K
12
1191
VERTEX RCCONSTRUCTION SYSTEM
K
11
3593
NEXTGEN ALTIUS OCT SYSTEM
K
11
3324
REXIOUS HOOK FIXATION SYSTEMS
K
11
2757
PIONEER POSTERIOR CERVICO THORACIC SYSTEM
K
11
3346
NEON SYSTEM
K
11
2595
COFLEX-F
K
11
1719
OASYS SPINAL SYSTEM
K
11
3654
CASPIAN
K
11
2592
AXLE PEEK INTERSPINOUS FUSION SYSTEM
K
11
2025
SURE LOK MINI POSTERIOR CERVICAL/UPPER THORACIC SYSTEM
K
10
3205
BRIDGEPOINT SPINOUS PROCESS CAMP- POSTERIOR FIXATION SYSTEM
K
11
1183
ASCENT POSTERIOR OCCIPITAL THORACIC (POCT) SYSTEM (TITANIUM & COBALT CHROME RODS)
K
11
0963
ELLIPSE OCCIPITO-CERVICO-THORACIC SPINAL SYSTEM
K
10
3091
LANX SPINAL FIXATION SYSTEM
K
11
0353
MOUNTAINEER OCT SPINAL SYSTEM
K
11
0522
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
K
11
0367
PIONEER SPINAL PROCESS FUSION PLATE
K
10
2886
CD HORIZON SPINAL SYSTEM
K
10
2195
SP-FIX SPINOUS PROCESS FIXATION PLATE
K
10
3232
CASPIAN SPINAL SYSTEM
K
10
1471
AXLE INTERSPINOUS FUSION SYSTEM
K
10
0888
MODIFICATION TO LANX POSTERIOR CERVICOTHORACIC SPINAL FIXATION SYSTEM
K
10
1183
MODIFICATION TO: OASYS SYSTEM
K
10
1112
RELIANCE SPINAL SCREW SYSTEM
K
10
1525
PIONEER SPINOUS PROCESS FUSION PLATE
K
09
3438
PARADIGM INTERSPINOUS FUSION PLATE
K
10
1084
CASPIAN SPINAL SYSTEM
K
10
2020
VEGA SPAN SPINOUS PROCESS PLATE SYSTEM
K
10
0354
PRIMAL OK INTERSPINOUS FUSION SYSTEM
K
09
3319
NUVASIVE VUEPOINT OCT SYSTEM
K
10
0685
ZODIAC POLYAXIAL SPINAL FIXATION SYSTEM
K
10
0191
LANX POSTERIOR CERVICOTHORACIC SPINAL FIXATION SYSTEM (PCFS)
K
09
2825
APEX SPINE SYSTEM 5.50 MM TITANIUM ROD & POLYAXIAL SCREW WASHER
K
09
2295
PIONEER POSTERIOR CERVICO-THORACIC SYSTEM
K
09
3534
MODIFICATION TO CASPIAN SPINAL SYSTEM
K
09
2656
LANX POSTERIOR CERVICOTHORACIC SPINAL FIXATION SYSTEM
K
09
1359
GSO PCT SPINAL SYSTEM
K
09
0343
SENTINEL SPINAL SYSTEM
K
09
1365
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
K
09
1689
SYNAPSE SYSTEM 4.0MM, OC FUSION SYSTEM 4.0MM
K
09
0565
ELLIPSE OCCIPITO-CERICO-THORACIC SPINAL SYSTEM
K
09
0060
NEXLINK OCT SYSTEM, MODEL 7000 SERIES
K
09
0549
SYNTHES SYNAPSE TRANSCONNECTOR
K
09
0714
VERTEX RECONSTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
K
09
0252
MODIFICATION TO: LANX SPINAL FIXATION SYSTEM
K
08
2728
VERTEX RECONTRUCTION SYSTEM, VERTEX SELECT RECONSTRUCTION SYSTEM
K
08
2769
MESA AND RANGE SPINAL SYSTEMS
K
08
3071
VERTEX RECONSTRUCTION SYSTEM
K
08
1906
PROTEX CT CERVICOTHORACIC SPINAL SYSTEM
K
08
1107
CASPIAN SPINAL SYSTEM, SCREWS, RODS, HOOKS, ROD CONNECTORS
K
08
1297
VERTEX RECONSTRUCTION SYSTEM
K
08
0790
MODIFICATION TO THEKEN ATOLL CERVICO-THORACIC SYSTEM
K
08
0805
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
07
2729
SIERRA
K
08
0526
SIERRA SYSTEM
K
07
3278
SPINOUS PROCESS PLATE SYSTEM
K
08
0394
BLACKSTONE ASCENT POSTERIOR OCCIPITAL CERVICO-THORACIC (POCT) SYSTEM
K
07
3420
BLACKSTONE ASCENT MULTIAXIAL SCREWS
K
07
3654
BLACKSTONE ASCENT POCT SYSTEM PARALLEL ROD CONNECTOR
K
07
2866
ISSYS LP SPINAL FIXATION SYSTEM
K
07
1942
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
07
2081
ZODIAC DYNAMO SEMI-RIGID SPINAL SYSTEM
K
06
2447
TRAVERSE OCT SPINAL FIXATION SYSTEM
K
07
2568
MODIFICATION TO OASYS SYSTEM
K
07
0742
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
07
1633
LANX DEFORMITY SYSTEM
K
07
0341
LDR SPINE EASYSPINE POSTERIOR OSTEOSYNTHESIS SYSTEM
K
07
1377
POLARIS BE RODS
K
07
0966
GSO GS1 SPINAL SYSTEM
K
07
0638
THEKEN ATOLL CERVICO-THORACIC SYSTEM
K
06
1943
ANATOMICA POSTERIOR CERVICAL FIXATION SYSTEM
K
07
0300
EXPEDIUM SFX CROSS CONNECTOR SYSTEM
K
06
2181
C-JAWS CERVICAL COMPRESSIVE MINI FRAME
K
06
2785
LTD POLYAXIAL FIXATION SYSTEM
K
06
2513
APEX SPINE SYSTEM
K
06
1591
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
05
3418
SYNTHES OC FUSION SYSTEM
K
06
1579
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
05
2404
DENALI DEFORMITY SYSTEM
K
06
0683
ENDIUS MINIT POSTERIOR CERVICAL AND UPPER THORACIC FIXATION SYSTEM
K
06
0513
SINTEA BIOTECH PLS MULTI-AXIAL SCREWS, MODEL PLS.XX.T5.X
K
06
0081
BASIS SPINAL SYSTEM
K
05
2201
SOLANAS POSTERIOR STABILIZATION SYSTEM
K
05
2734
MODIFICATION TO: VERTEX RECONSTRUCTION SYSTEM
K
05
2131
EXPEDIUM SPINE SYSTEM 5.5MM COMMERICALLY PURE TITANIUM SPINAL RODS
K
05
2402
VERTEX RECONSTRUCTION SYSTEM
K
05
2376
MODIFICATION TO: VERTEX RECONSTRUCTION SYSTEM
K
05
2123
SYNTHES PANGEA SYSTEM
K
05
2247
NEX-LINK SPINAL FIXATION SYSTEM VARIABLE CROSSLINK, MODEL 721-XX
K
05
2181
MODIFICATION TO XIA SPINAL SYSTEM
K
05
1716
VERTEBRON PSS PEDICLE SCREW SYSTEM
K
05
2180
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
05
1973
MODIFICATION TO: XIA STAINLESS STEEL SYSTEM
K
05
2069
PROTEX STABILIZATION SYSTEM WITH ADDITIONAL COMPONENTES
K
05
1942
MALIBU SPINAL SYSTEM
K
05
0391
PROTEX CT CERVICOTHORACIC SPINAL SYSTEM
K
05
0830
ZODIAC SPINAL FIXATION SYSTEM
K
05
0809
CD HORIZON SPINAL SYSTEM
K
05
0484
BASIS SPINAL SYSTEM
K
04
3053
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
05
0189
TECHTONIX SYSTEM
K
05
0079
CD HORIZON SPINAL SYSTEM
K
04
3522
ISSYS PEDICLE SCREW SYSTEM
K
04
3473
MODIFICATION TO XIA SPINAL SYSTEM
K
04
2635
DENALI SPINE SYSTEM
K
04
3020
GLAXY 3.2 SPINAL SYSTEM
K
04
3229
MODIFICATION TO ALTIUS OCT SYSTEM
K
04
2789
VERTEX RECONSTRUCTION SYSTEM
K
04
3355
SINTEA BIOTECH POSTERIOR LUMBAR SYSTEM WITH POLYAXIAL AND RECOVERY SCREWS, MODEL PLS.01.T5.X
K
04
2673
ZODIAC POLYAXIAL SPINAL FIXATION SYSTEM
K
04
2524
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
04
2508
SUMIT OCT SPINAL SYSTEM AND MOUNTAINEER OCT SPINAL SYSTEM
K
04
2498
VERTEX RECONSTRUCTION SYSTEM
K
04
2143
EXCELLA-M SPINAL SYSTEM
K
04
2402
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
04
1808
ENDIUS TITLE 2 POLYAXIAL SPINAL SYSTEM
K
04
1925
ST360 SPINAL FIXATION SYSTEM
K
04
1592
CORAL SPINAL SYSTEM
K
04
1862
CD HORIZON SPINAL SYSTEM
K
04
1119
EXPEDIUM SPINE SYSTEM
K
04
1449
SYNERGY HELICAL FLANGE PLUG, HELICAL FLANGE SEAT AND HELICAL FLANGE REDUCTION SEAT
K
04
0096
SPINAL CONCEPTS, INC. TANDEM SPINOUS PROCESS PLATE SYSTEM
K
04
1282
MODIFICATION TO TSRH SPINAL SYSTEM
K
03
3961
ALTIUS OCT SYSTEM
K
03
3090
ICON POLYAXIAL PEDICLE SCREW SYSTEM
K
03
3980
BLACKSTONE ASCENT POCT SYSTEM HOOKS (SYSTEM MODIFICATION)
K
03
2094
PASSMED SPINAL SYSTEM
K
03
1175
CLICK'X MONOAXIAL SCREWS AND HOOKS
K
03
1471
ORIA SPINAL CLIP SYSTEM, LATERAL INTERMEDIATE CONNECTOR, MODEL AL01
K
03
1772
TI FENESTRATED PLATE
K
02
3884
MODIFICATION ORIA SPINAL SYSTEM
K
03
1893
XIA SPINAL SYSTEM AND XIA STAINLESS STEEL SYSTEM
K
03
1595
U & I AMERICA SPINAL HOOK SYSTEM
K
03
0875
MODIFICATION TO COLORADO 2 SPINAL SYSTEM
K
03
1452
ORIA SPINAL CLIP SYSTEM, SACRAL CONNECTOR, MODELS CA03 AND AO03
K
03
1533
VANTAGE ANTERIOR FIXATION SYSTEM
K
03
0197
BLACKSTONE POSTERIOR CERVICAL SYSTEM
K
03
0816
MSD CABLE REDUCTION SYSTEM
K
03
1090
MODIFICATION TO XIA STAINLESS STEEL SYSTEM
K
03
0252
ORIA SPINAL CLIP SYSTEM EXTENDED OMNIAXIAL CONNECTORS (CO05 & CO07)
K
03
0253
ORIA SPINAL CLIP SYSTEM, LENGTHENED LATERAL CONNECTOR, MODEL AL06
K
03
0241
MODIFICATION TO BLACKSTONE SPINAL FIXATION SYSTEM
K
02
3804
MOSS MIAMI SPINAL SYSTEM PIN NUT
K
02
3797
LAURAIN DEWALD ANTERIOR FIXATION SYSTEM
K
02
3415
MODIFICATION TO DYNALOK CLASSIC SPINAL SYSTEM
K
01
4296
CD HORIZON SPINAL SYSTEM
K
02
2048
INTERPORE CROSS INTERNATIONAL (ICI) OCCIPITO-CERVICO-THORACIC (OCT) ROD AND PLATE SYSTEM
K
02
3675
SYNTHES CERVIFIX/ AXON
K
02
3555
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
02
1679
ORIA SPINAL CLIP SYSTEM
K
02
3498
MODIFICATION TO BLACKSTONE SPINAL FIXATION SYSTEM
K
02
2374
CADENCE SPINAL FIXATION SYSTEM
K
02
2191
MODIFICATION TO TENOR SPINAL SYSTEM
K
02
2623
5.0 MM DIAMETER POLYAXIAL SCREWS (MOSS MIAMI 6.35MM SYSTEM)
K
02
1507
PLUS PIVOT LINK UNIVERSAL SYSTEM
K
02
1061
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
02
2070
XANTUS ANTERIOR LATERAL SUPPLEMENTAL FIXATION SYSTEM
K
02
2015
MODIFICATION TO VERTEX RECONSTRUCTION SYSTEM
K
02
1170
TSRH SPINAL SYSTEM
K
02
1919
SCS CLARIS SPINAL SYSTEM,REXTENDED OMNIAXIAL CONNECTOR-,MEDIUM, MODEL CO05, SCS CLARIS SPINAL SYSTEM,EXTENDED OMNIAXIALO
K
02
1825
MODIFICATION TO SPIRAL RADIUS 90-D SST SYSTEM
K
02
1009
OCTAFIX OCCIPITAL CERVICAL PLATING SYSTEM
K
02
0709
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
02
0134
SPIRAL RADIUS 90-D RODDING SYSTEM
K
01
4090
ENDIUS SPINAL FIXATION SYSTEM
K
02
0426
MSD WIRE SYSTEM
K
02
0236
MODIFICATION TO PASS SPINAL SYSTEM
K
01
3312
P.L.U.S. SYSTEM (PIVOT LINK UNIVERSAL SYSTEM)
K
02
0155
DYNA-LOK CLASSIC SPINAL SYSTEM
K
01
3196
ASCEND SPINAL FIXATION SYSTEM WITH THE SHADOW SPINAL SYSTEM
K
01
4267
BUTTERFLY PLATE FIXATION SYSTEM
K
01
3447
ISOBAR SPINAL SYSTEM
K
01
3442
PASS SPINAL SYSTEM
K
01
3823
XIA SPINAL SYSTEM
K
01
2516
EBI SPINELINK - II SPINAL FIXATION SYSTEM
K
01
3441
ISOLA POLYAXIAL WASHER
K
01
2173
DEVICE MODIFICATION OF SILHOUETTE SPINDAL FIXATION SYSTEM
K
00
3780
VERTEX RECONSTRUCTION SYSTEM
K
01
2870
XIA STAINLESS STEEL SYSTEM
K
01
2871
SYNERGY TI INTEGRAL OPEN SCREWS MODELS # 6193, 6194, 6195,6196, 6173, 6174, 6175, 6176, 6177
K
01
1830
TRI-FIX SPINAL FIXATION SYSTEM
K
01
1969
SYNTHES CERVIFIX SYSTEM
K
01
0681
SUMMIT OCCIPITO-CERVICO-THORACIC (OCT) SPINAL SYSTEM
K
00
3823
SCS DT-02 TRANSVERSE CONNECTOR
K
01
1508
CD HORIZON SPINAL SYSTEM
K
01
0181
CD HORIZON SPINAL SYSTEM, 4.5 ROD FOR POSTERIOR APPLICATION
K
01
0632
BUTTERFLY PLATE FUNCTION SYSTEM
K
01
0515
MODIFICATION TO SYNERGY SPINAL SYSTEM
K
00
1535
ZENITH PLATE SYSTEM, ANTERIOR SPINAL INSTRUMENTATION
K
00
3911
TERRAY STAINLESS STEEL ROD (STRAIGHT, L, RECTANGLE)
K
00
3351
PARSFIX CABLE-SCREW SYSTEM
K
00
3822
ISOLA CLOSED DUAL ROD CONNECTOR
K
00
2733
SUMMIT OCCIPITO-CERVICO-THORACIC (OCT) SPINAL SYSTEM
K
00
2059
AMT SPINAL SYSTEM
K
00
2103
SIMPLICITY SPINAL SYSTEM
K
00
2959
MODIFICATION TO ISOBAR SPINAL SYSTEM
K
00
2082
SPEEDLINK TRANSVERSE CONNECTOR
K
00
2505
XIA SPINE SYSTEM
K
00
2069
ASCEND SPINAL FIXATION SYSTEM
K
00
2607
MOSS MIAMI 6.35MM ROD SYSTEM MONOAXIAL SCREWS, POLYAXIAL REDUCTION SCREWS AND SACRAL EXTENDERS
K
00
2517
USS VAS
K
00
1653
XIA SPINE SYSTEM SACRAL BLOCK ASSEMBLY
K
00
1470
E-Z LINK CROSS CONNECTOR
K
00
1372
E-Z LINK CROSS CONNECTOR
K
00
1080
SPINE SYSTEM EVOLUTION
K
00
1532
DYNA-LOK CLASSIC SPINAL SYSTEM
K
00
1105
MOSS MIAMI 6.35MM ROD SYSTEM PEDICLE AND LAMINAR HOOKS
K
99
4187
SYNTHES CERVIFIX SYSTEM
K
99
2885
VERSALOK LOW BACK FIXATION SYSTEM
K
99
3067
SILHOUETTE SPINAL FIXATION SYSTEM
K
99
1662
TITANIUM HARTSHILL SYSTEM
K
99
0986
CONTOUR SPINAL SYSTEM
K
99
1198
DYNA-LOK PLUS SPINAL SYSTEM
K
99
1089
SYNTHES CERVIFIX SYSTEM
K
99
1586
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
K
99
0965
SYNTHES CERVIFIX SYSTEM
K
99
0922
OSTEONICS SPINAL SYSTEM VERSATILE CROSS CONNECTOR
K
98
4375
OSTEONICS SPINAL SYSTEM - SACRAL OFFSET CONNECTOR ASSEMBLY
K
99
0303
EBI OMEGA 21 SYSTEM
K
99
0845
MODIFICATION TO PARTS NUMBERED CGT-SL AND CGT-SL-15
K
99
0708
TITANIUM VERSALOK
K
98
1676
CD HORIZON SPINAL SYSTEM
K
98
4377
SYNTHES SPINE CERVIFIX SYSTEM
K
98
3904
ROGOZINSKI SPINAL ROD SYSTEM
K
98
3353
SCS SPINAL SYSTEM
K
98
3530
SYNTHES POSTERIOR UNIVERSAL SPINAL SYSTEM
K
98
3583
DEPUY ACROMED MOSS AND MOSS MIAMI SPINAL SYSTEMS
K
98
2322
SYNTHES SPINE OCCIPITAL-CERVICAL PLATE/ROD AND HOOK SYSTEM
K
98
3282
OMI OCCIPITAL CERVICAL LOOP, MODEL A1089
K
98
3706
MODIFICATION OF TOWNLEY PEDICLE SCREW PLATING SYSTEM
K
98
3197
SURGICAL DYNAMICS RODDING SYSTEM (PREVIOUSLY KNOWN AS THE AURORA TITANIUM SPINAL ROD SYSTEM)
K
98
2490
TENOR SPINAL SYSTEM
K
98
2511
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEMS
K
98
2320
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
K
98
2494
BWM SPINE SYSTEM
K
98
2908
MODIFICATION TO EBI SPINELINK SYSTEM
K
98
2011
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
K
98
0288
SPINE-TECH SILHOUETTE SPINAL FIXATION SYSTEM
K
98
0121
AESCULAP SPINE SYSTEM ADDITIONAL COMPONENTS
K
98
1452
OSTEONICS LONG ARM CONTAINMENT RING
K
98
0928
SYNTHES SPINE UNIVERSAL SPINAL HOOK, ROD, PEDICLE/SACRAL SCREW FIXATION SYSTEM
K
98
0358
SYNTHES SPINE POSTERIOR CERVICAL/THORACIC HOOK/ROD SYSTEM
K
97
4573
DEPUY MOTECH MOSS-MIAMI SPINAL SYSTEM
K
97
3868
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
K
96
4159
CD SPINAL SYSTEM
K
96
5221
RANSFORD CERVICAL FIXATION SYSTEM
K
97
1457
BRYAN POSTERIOR SPINAL FIXATOR (BPSF), MODIFIED
K
97
1289
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
K
96
5224
EMPOWER ANTERIOR DIRECT SCREWS
K
96
4254
TITANIUM LIBERTY POSTERIOR SPINAL SYSTEM
K
96
4404
BACFIX SPINAL FIXATION SYSTEM
K
96
4024
DEPUY MOTECH TITANIUM MOSS MIAMI SPINAL SYSTEM
K
96
2628
MOSS MIAMI SPINAL SYSTEM
K
96
5145
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
K
96
2708
TITANIUM CD HORIZON SPINAL SYSTEM
K
96
0444
FINN ROD TO ROD CONNECTOR
K
96
4275
ALPHA POSTERIOR SPINAL SYSTEM
K
96
2314
HALIFAX PLUS INTERLAMINAR CLAMP SYSTEM
K
96
1633
CD HORIZON SPINAL SYSTEM
K
96
2984
ISOLA PEDIATRIC COMPONENTS
K
96
3639
ACROMED PEDICLE SCREW
K
95
5807
COTREL-DUBOUSSET (CD) SPINAL
K
95
5365
COMPACT COTREL-DUBOUSSET (CCD) SPINAL SYSTEM
K
95
5864
J.B. S. C1-C2 CLAMP
K
95
5927
BRYAN POSTERIOR SPINAL FIXATOR (MODIFICATION)
K
95
4696
ROGOZINSKI THORACOLUMBAR SPINAL ROD
K
95
5348
TITANIUM MOSS MIAMI SPINAL SYSTEM
K
95
1846
MIRAGE SPINAL SYSTEM FOR SEVERE SPONDYLOLISTHESIS
K
95
5173
SSCS (SEGMENTAL SPINAL CORRECTION SYSTEM)
K
95
1164
CD LIBERTY POSTERIOR SPINCAL SYSTEM
K
95
4770
CENTRA-LINE GRAPPLE, VARIFIX SYSTEM
K
95
4645
TITANIUM GDLH POSTERIOR SPINAL SYSTEM
K
95
3599
CLAMP ASSEMBLY
K
93
6294
SENTRY(TM) ANTERIOR/POSTERIOR SPINAL SYSTEMS
K
94
2432
J.B.S. CERVICAL SPINE SYSTEM
K
94
5781
WEBB-MORLEY SPINE SYSTEM
K
94
5435
BRYAN POSTERIOR SPINAL FIXATOR (BPSF)
K
94
5022
APOFIX CERVICAL SPINE FIXATION
K
93
1381
AME UNIVERSAL FIXATION SYSTEM
K
93
5113
J.B.S. IMPLANTABLE SPINAL FIXATION DEVICE
K
93
0009
STRYKER 2S SPINAL SYSTEM
K
93
3881
DEPUY MOTECH MOSS-MIAMI SPINAL SYSTEM
K
93
0657
D-C-S SYSTEM
K
93
0515
ALPHA SPINAL SYSTEM
K
93
4582
GDLH VARIABLE ANGLE CONNECTOR
K
93
4860
TI-FRAME
K
93
4007
SOFAMOR ORFIL SPINE FIXATION SYSTEM
K
93
3205
TSRH(R) TOP TIGHT T-BOLT-VARI ANGLE/SCREW/PARAGON
K
93
1225
LOW PROFILE MID CROSS BRACING
K
93
0891
SYNTHES (USA) UNIV SPINE ROD/SACRAL SCREW FIX SYST
K
93
1208
LOW PROFILE SLEAVE NUT ASSEMBLY
K
91
4548
BRYAN SPINAL FIXATER (BSF)
K
93
0531
AME(R) RIGID FIXATION SYSTEM
K
93
0710
SENTRY POSTERIOR SPINAL SYSTEM
K
92
4474
SELBY INSTRUMENTATION
K
92
1056
COTREL - DUBOUSSET SPINE IMPLANTS
K
92
1948
SYNTHES UNIVERSAL SPINE HOOK AND ROD FIXATION SYST
K
92
1767
COMPACT COTREL -- DUBOUSSET SPINE SYSTEM
K
92
4142
CODMAN(TM) TITANIUM INTERLAMINAR CLAMP KIT
K
91
5672
EDWARDS ADJUSTABLE CONNECTORS
K
92
4381
PWB LUMBAR LAMINAR HOOKS WITH SET SCREWS
K
92
5811
TSRH CENTRAL POST HOOKS
K
92
2672
AUGMENT POSTERIOR SPINAL FIXATION SYSTEM
K
92
2504
ISOLA(R) TANDEM CONNECTOR
K
92
1256
LUQUE V SPINAL SYSTEM
K
92
0546
PARAGON POSTERIOR SPINAL SYSTEM
K
92
1090
ISOLA(R) TRANSVERSE ROD DUAL CONNECTOR
K
92
0392
ISOLA SPINE SYSTEM: PLATE-ROD COMBINATION
K
92
2238
LEAPLAZA FRAME
K
92
2520
MODIFIED TSRH CENTRAL POST HOOKS
K
92
3339
TSRH L CONNECTOR -- MODIFICATION
K
91
2837
MCAFEE SPINAL SYSTEM FOR POSTERIOR APPLICATIONS
K
91
4306
TSRH(TM) LATERAL OFFSET PLATE
K
91
4966
TSRH CENTRAL POST HOOKS
K
92
0102
THE SELBY SYSTEM
K
92
0116
PWB LUMBOSACRAL SPINE SYSTEM
K
91
1663
CROSSLINK SYSTEM
K
90
4243
TSRH VARIABLE ANGLE SACRAL SCREW
K
91
3561
LUQUE SEGMENTAL SPINAL INSTRUMENTATION
K
91
4269
EDWARDS ANATO HOOK/UNIV ROD/WASH/SACR SCREW/ADJ CO
K
90
4520
RAY SACRAL FIXATION SYSTEM
K
91
1307
CROSSLINK PLATE
K
91
1379
DANEK SACRAL HOOK, MODIFICATION
K
91
1319
TSRH OPEN HEAD BONE SCREW
K
91
1528
ISOLA(TM) SPINE SYSTEM - ILIAC SCREW
K
91
1394
ISOLA(TM) SPINE SYSTEM--EYE ROD
K
90
5826
ISOLA SLOTTED CONNECT/ANGLED SLOTTED CONNECTOR
K
90
5184
ISOLA(TM) SPINE SYSTEM TOP ENTRY HOOK
K
90
3376
ACROMED SACRAL SCREW
K
90
2775
KNIGHT SACRAL SCREW
K
90
1005
TSRH SPINAL SYSTEM (ADD'L SIZES OF HOOKS)
K
90
3461
TSRH OFFSET AND SIDE-LOADING HOOKS
K
90
2397
MODULOCK POSTERIOR SPINAL FIXATION
K
90
1587
TSRH SACRAL L-CONNECTOR
K
90
1590
DANEK SACRAL HOOK
K
89
5978
CHIBA SPINAL SYSTEM
K
89
6106
ROGOZINSKI SPINAL SYSTEM, ADD'L COMPONENTS
K
89
6254
DANEK PRECISION ROD SET
K
89
5296
SELBY II INSTRUMENTATION
K
89
6740
AXIAL AND OFFSET CROSSLINK PLATES
K
89
6603
HSC UNIT ROD
K
89
0192
LUQUE III SPINAL SYSTEM AND LUQUE MINI-SET
K
89
5441
ACROMED BUTTON SPINAL WIRE
K
89
5413
ACROMED DOUBLE SUBLAMINAR WIRE
K
89
5439
ACROMED BEADED SUBLAMINAR WIRE
K
89
4702
STUART CD UNIVERSAL ROD CONNECTOR CLAMPS
K
89
4472
CROSS ROUND & SQUARE SPINAL RODS & DIST. SPINAL
K
88
4998
SELBY INSTRUMENTATION
K
88
4690
KIRSCHNER SPINAL FIXATOR KMS-1
K
88
4161
ACROMED ILIAC SCREW
K
88
4163
ACROMED SPINAL ROD AND SPINAL HOOKS
K
89
0187
THE C-S DISTRACTION ROD ASSEMBLY
K
88
3783
TSRH SACRAL SPINAL SCREW
K
88
4688
MODULAR SPINAL FIXATION & LOCKING HOOK SPINAL ROD
K
88
4585
LEA PLAZA SPINAL FRAME SYSTEM
K
88
4263
ROGOZINSKI SPINAL SYSTEM
K
88
2070
LUMBAR IMPACTION SET AND BONE GRAFT IMPACTORS
K
88
2068
COBB SPINAL ELEVATORS
K
88
0212
TSRH H/M HOOK HOLDER W/ROD MOVER
K
88
0211
TSRH H/M HOOK HOLDER
K
87
5290
LUMBAR IMPACTION SET
K
88
0215
TSRH H/M HOOK, EYEBOLT/LOCK NUT ASSEM., SPINAL ROD
K
88
0214
TSRH H/M TORQUE LIMITING WRENCH
K
87
4882
ACROMED CROSS ROD CONNECTOR
K
87
1870
HSC UNIT ROD
K
87
0085
ANTERIOR SPINAL FIXATION PLATE
K
87
0830
WARSAW ORTHOPEDIC TSR CROSS LINK SYSTEM
K
85
4770
MARTIN LAMINAR OSTEOSYNTHESIS SYSTEM
K
85
4524
KIRSCHNER SPINAL PRODUCT SYSTEM
K
85
4313
SONGER TITANIUM SPINE-L-ROD
K
85
1935
EDWARDS SACRAL SCREW
K
85
0039
HALIFAX SPINAL CLAMP
K
84
3445
SACRAL BAR
K
84
3687
ROD FOR RACHIS SURGERY
K
84
0423
HARRINGTON-TYPE INSTRU-SCOLIOSIS
K
82
0660
A HOOK DRIVER
K
81
0329
DEPUY SEGMENTALSPINAL SYSTEM
K
81
0224
ARMSTRONG SPINAL APPLIANCE
K
80
2462
SYNTHES SPINAL IMPLANT SYSTEM
K
80
1120
DUNN ANTERIOR DISTRACTION SYSTEM
K
80
1080
EDWARDS ROD SLEEVES
K
79
1009
SANTA CASA DISTRACTOR
K
79
0465
KNEE COMPRESSION HOOK SYSTEM
K
79
0238
TRANSVERSE TRACTION ASSEMBLY
K
78
1444
OUTRIGGER DISTRACTION UNIT
K
78
1443
HARRINGTON SPINE INSTRUMENTATION
KWQ
Appliance, Fixation, Spinal Intervertebral Body
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
KXA
Prosthesis, Hip, Femoral, Resurfacing
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
KXD
Prosthesis, Hip, Constrained, Metal
KXE
Prosthesis, Wrist, Hemi-, Ulnar
KYI
Prosthesis, Wrist, Carpal Trapezium
KYJ
Prosthesis, Finger, Constrained, Polymer
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
KYN
Prosthesis, Wrist, Constrained, Metal
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
LOD
Bone Cement
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
LRN
Wire, Surgical
LTO
Spacer, Cement
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
LYP
Accessories, Fixation, Spinal Interlaminal
LYT
Fixation Accessory
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
MBB
Bone Cement, Antibiotic
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
MJW
Prosthesis, Subtalar, Plug, Polymer
MNH
Orthosis, Spondylolisthesis Spinal Fixation
MNI
Orthosis, Spinal Pedicle Fixation
MNU
Staple, Absorbable
MQP
Spinal Vertebral Body Replacement Device
MQV
Filler, Bone Void, Calcium Compound
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
NDD
Cerclage, Fixation, Metallic
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
NDK
System, External Fixator (With Metallic Invasive Components)
NDL
Pin, Fixation, Smooth, Metallic
NDM
Pin, Fixation, Threaded, Metallic
NDN
Cement, Bone, Vertebroplasty
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
NKB
Thoracolumbosacral Pedicle Screw System
NKG
Posterior Cervical Screw System
NOV
Anchor, Suture, Bone Fixation, Metallic
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
NQP
Posterior Metal/Polymer Spinal System, Fusion
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
NUD
Vertebroplasty Compound, Calcium Based
NVC
Bone, Heterograft
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
OOG
Knee Arthroplasty Implantation System
OOL
Electronic Depth Gauge
OQB
Intervertebral Body Graft Containment Device
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
OSN
Software For Diagnosis/Treatment
OUR
Sacroiliac Joint Fixation
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
OVZ
Pin, Fixation, Resorbable, Hard Tissue
OWI
Bone Fixation Cerclage, Sublaminar
OYK
Ankle Arthroplasty Implantation System
OZI
Internal Hinged Elbow Fixator
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
PBF
Orthopaedic Surgical Planning And Instrument Guides
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
PEK
Spinous Process Plate
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
PHQ
Anterior Staple As Supplemental Fixation For Fusion
PHX
Shoulder Prosthesis, Reverse Configuration
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
PLF
Bone Wedge
PLR
Spinal Vertebral Body Replacement Device - Cervical
PLW
Acetabular Cup Orientation System
PML
Bone Cement, Posterior Screw Augmentation
PPQ
Transtibial Anterior Cruciate Ligament Kit
QHQ
Total Shoulder Arthroplasty System
PQC
Pedicle Screw Placement Guide
QAC
Screw Sleeve Bone Fixation Device
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
QFP
Intraoperative Orthopedic Strain Sensor
QHE
Shoulder Arthroplasty Implantation System
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
JDK
Prosthesis, Hip, Cement Restrictor
LZN
Cement Obturator
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
QSD
Posterior Cervical Screw Placement Guide
QSR
Sacroiliac Screw Placement Guide
QVI
Screw Sleeve Bone Fixation Device, Spine
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
SAI
Ankle Fusion Cage
SCY
Sacroiliac Joint Guidewire Placement Device
Subpart E—Neurological Surgical Devices
Subpart E—Surgical Devices
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OR
/
subpart-d—prosthetic-devices
/
KWP
/
K031893
View Source
XIA SPINAL SYSTEM AND XIA STAINLESS STEEL SYSTEM
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K031893
510(k) Type
Special
Applicant
Howmedica Osteonics Corp.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
7/17/2003
Days to Decision
28 days
Submission Type