NKG · Posterior Cervical Screw System

Orthopedic · 21 CFR 888.3075 · Class 2

Overview

Product CodeNKG
Device NamePosterior Cervical Screw System
Regulation21 CFR 888.3075
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

Posterior cervical screw systems are comprised of multiple, interconnecting components, made from a variety of materials that allow an implant system to be built from the occiput to the upper thoracic spine to fit the patient's anatomical and physiological requirements, as determined by preoperative cross-sectional imaging. Such a spinal assembly consists of a combination of bone anchors via screws (i.e., occipital screws, cervical lateral mass screws, cervical pedicle screws, C2 pars screws, C2 translaminar screws, C2 transarticular screws), longitudinal members (e.g., plates, rods, including dual diameter rods, plate/rod combinations), transverse or cross connectors, interconnection mechanisms (e.g., rod-to-rod connectors, offset connectors), and closure mechanisms (e.g., set screws, nuts). Posterior cervical screw systems are rigidly fixed devices that do not contain dynamic features, including but not limited to: non-uniform longitudinal elements or features that allow more motion or flexibility compared to rigid systems.Posterior cervical screw systems are intended to provide immobilization and stabilization of spinal segments in patients as an adjunct to fusion for acute and chronic instabilities of the cervical spine and/or craniocervical junction and/or cervicothoracic junction such as: (1) Traumatic spinal fractures and/or traumatic dislocations; (2) deformities; (3) instabilities; (4) failed previous fusions (e.g., pseudarthrosis); (5) tumors; (6) inflammatory disorders; (7) spinal degeneration, including neck and/or arm pain of discogenic origin as confirmed by imaging studies (radiographs, CT, MRI); (8) degeneration of the facets with instability; and (9) reconstruction following decompression to treat radiculopathy and/or myelopathy. These systems are also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion.

Classification Rationale

Class II (special controls). The special controls for posterior cervical screw systems are:

Special Controls

*Classification.* Class II (special controls). The special controls for posterior cervical screw systems are:(1) The design characteristics of the device, including engineering schematics, must ensure that the geometry and material composition are consistent with the intended use. (2) Nonclinical performance testing must demonstrate the mechanical function and durability of the implant. (3) Device components must be demonstrated to be biocompatible. (4) Validation testing must demonstrate the cleanliness and sterility of, or the ability to clean and sterilize, the device components and device-specific instruments. (5) Labeling must include the following: (i) A clear description of the technological features of the device including identification of device materials and the principles of device operation; (ii) Intended use and indications for use including levels of fixation; (iii) Device specific warnings, precautions, and contraindications that include the following statements: (A) “Precaution: Preoperative planning prior to implantation of posterior cervical screw systems should include review of cross-sectional imaging studies ( *e.g.,* CT and/or MRI) to evaluate the patient's cervical anatomy including the transverse foramen, neurologic structures, and the course of the vertebral arteries. If any findings would compromise the placement of these screws, other surgical methods should be considered. In addition, use of intraoperative imaging should be considered to guide and/or verify device placement, as necessary.”(B) “Precaution: Use of posterior cervical pedicle screw fixation at the C3 through C6 spinal levels requires careful consideration and planning beyond that required for lateral mass screws placed at these spinal levels, given the proximity of the vertebral arteries and neurologic structures in relation to the cervical pedicles at these levels.” (iv) Identification of magnetic resonance (MR) compatibility status; (v) Cleaning and sterilization instructions for devices and instruments that are provided non-sterile to the end user, and; (vi) Detailed instructions of each surgical step, including device removal.

Recent Cleared Devices (20 of 117)

Showing 20 most recent of 117 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K254045CarboClear® Posterior Cervical Screw System; CarboClear® Hybrid Posterior Cervical Screw SystemCarboFix Orthopedics , Ltd.Mar 16, 2026SESE
K254165Infinity™ OCT SystemMedtronic Sofamor Danek USA, Inc.Jan 21, 2026SESE
K252327CMORE® CT System; CMORE® CT System Navigated InstrumentsIcotec AGNov 12, 2025SESE
K253129Infinity™ OCT SystemMedtronic Sofamor Danek USA, Inc.Oct 24, 2025SESE
K251725ANAX™ OCT Spinal SystemCg Medtech Co., Ltd.Jun 25, 2025SESE
K250866Sovereign Posterior Cervical SystemMet One Technologies, LLCMay 20, 2025SESE
K242674Freedom Posterior Cervical ScrewsSignature Orthopaedics Pty, Ltd.May 13, 2025SESE
K250332Virage® OCT Spinal Fixation SystemHighridge Medical, LLCApr 4, 2025SESE
K242516EUROPA™ Posterior Cervical Fusion SystemMiRus, LLCNov 19, 2024SESE
K233989CarboClear® Posterior Cervical Screw SystemCarboFix Orthopedics , Ltd.Mar 27, 2024SESE
K231850QUARTEX® Occipito-Cervico-Thoracic Spinal System ExcelsiusGPS® InstrumentsGlobus Medical, Inc.Mar 14, 2024SESE
K233332Statera-C™ Spinal SystemK&J Consulting Corp.Nov 27, 2023SESE
K233078Posterior Cervical Spine SystemDouble Medical Technology, Inc.Nov 22, 2023SESE
K233366SYMPHONY OCT SystemMedos International SARLNov 9, 2023SESE
K232167VySpan™ PCT SystemVy Spine, LLCSep 27, 2023SESE
K231654NorthStar OCT SystemSeaspine, Inc.Aug 3, 2023SESE
K231840CastleLoc-S Posterior Cervical Fixation SystemL&K BIOMED Co., Ltd.Jul 20, 2023SESE
K221307Edge Upper Cervical SystemSpinal Simplicity, LLCJul 10, 2023SESE
K230614Cortium™Ulrich Medical USAMay 2, 2023SESE
K223852VySpan™ PCT SystemVy Spine, LLCFeb 24, 2023SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...