JDO · Device, Fixation, Proximal Femoral, Implant

Orthopedic · 21 CFR 888.3030 · Class 2

Overview

Product CodeJDO
Device NameDevice, Fixation, Proximal Femoral, Implant
Regulation21 CFR 888.3030
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Classification Rationale

Class II.

Recent Cleared Devices (20 of 23)

Showing 20 most recent of 23 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K230764OsteoCentric Integrated Hip Fastener SystemOsteoCentric TechnologiesApr 18, 2023SESE
K213126Smith & Nephew, Inc. Plates and Screws Systems: EVOS, Peri-Loc, D-Rad, TC-100, VLP Mini-Mod, Compression Hip Screw (CHS), CONQUEST FN, and cannulated screwsSmith & Nephew, Inc.Sep 29, 2022SESE
K210247OsteoCentric Integrated Hip Fastener SystemOsteocentric Technologies D.B.A. Osteocentric TraumaApr 30, 2021SESE
K193029CONQUEST FNSmith & Nephew, Inc.Feb 28, 2020SESE
K173826THP Hip Fracture Plating SystemBiomet, Inc.Feb 7, 2018SESE
K172785CONQUEST FNSmith & NephewDec 22, 2017SESE
K152686CONQUEST FNSmith & NephewMar 17, 2016SESE
K140018TSP HIP FRACTURE PLATING SYSTEMBiomet, Inc.Apr 4, 2014SESE
K080685HIPLOC COMPRESSION HIP SCREWBiomet Manufacturing, Inc.Aug 15, 2008SESE
K080434INTERTAN CHS LOCKING PLATE SYSTEM PROX FEM PLATES/SCREWSmith & Nephew, Inc.Apr 10, 2008SESE
K983814GOTFRIED PERCUTANEOUS COMPRESSION PLATING SYSTEMEfratgo, Ltd. HI Tech Bio-SurgicalJan 14, 1999SESE
K981757SYNTHES (USA) DHS HELIX SYSTEMSynthes (Usa)Jul 17, 1998SESE
K964259SYNTHES (USA) DDHS/DCS SYSTEM MODIFICATIONSynthes (Usa)Jan 9, 1997SESE
K962644VIGOR COMPRESSION HIP SCREW SYSTEMDeutschland Surgical, Inc.Sep 6, 1996SESE
K953607TITANIUM LIMITED CONTACT DYNAMIC HIP SCREW PLATE (TILC-DHS)Synthes (Usa)Mar 8, 1996SESE
K951904SYNTHES (USA) [SYNTHES] POINT CONTACT FIXATOR PLATE [PC-FIX]Synthes (Usa)Jul 17, 1995SESE
K934161PROFORM HIP SYSTEMStelkast CompanyMar 10, 1994SESE
K934162PROFORM HA HIP SYSTEMStelkast CompanyMar 9, 1994SN
K923613SYNTHES LIMITED CONTACT-DYNAMIC HIP SCREW IMPLANTSynthes (Usa)Jun 22, 1993SESE
K831076COMPRESSION SYSTEMKirschner Medical Corp.Apr 28, 1983SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...