21 CFR 888.3030 — Plate, Fixation, Bone
Orthopedic (OR) · Part 888 Subpart D—Prosthetic Devices · § 888.3030
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.
Classification Rationale
Class II.
Product Codes
| Product Code | Device Name | Class | Devices | Attributes |
|---|---|---|---|---|
| HRS | Plate, Fixation, Bone | 2 | 1311 | Implant |
| HTN | Washer, Bolt Nut | 2 | 92 | Implant |
| JDO | Device, Fixation, Proximal Femoral, Implant | 2 | 23 | Implant |
| JDP | Condylar Plate Fixation Implant | 2 | 2 | Implant |
| JDR | Staple, Fixation, Bone | 2 | 231 | Implant |
| JDS | Nail, Fixation, Bone | 2 | 53 | Implant |
| KTT | Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component | 2 | 403 | Implant |
| KTW | Appliance, Fixation, Nail/Blade/Plate Combination, Single Component | 2 | 38 | Implant |
| KWK | Appliance, Nail/Blade/Plate Combination, Single Component | 2 | 1 | Implant |
| LRN | Wire, Surgical | 2 | 8 | Implant |
| LXT | Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite | 2 | 57 | Implant |
| LYT | Fixation Accessory | 2 | 9 | Implant |
| MAI | Fastener, Fixation, Biodegradable, Soft Tissue | 2 | 220 | Implant |
| MNU | Staple, Absorbable | 2 | 4 | Implant |
| NDF | Plate, Fixation, Bone, Non-Spinal, Metallic | 2 | 3 | Implant |
| NDG | Washer, Bolt, Nut, Non-Spinal, Metallic | 2 | 1 | Implant |
| NDH | Nail, Fixation, Bone, Metallic | 2 | 0 | Implant |
| NDI | Staple, Fixation, Bone, Metallic | 2 | 0 | Implant |
| NOV | Anchor, Suture, Bone Fixation, Metallic | 2 | 1 | Implant |
| OBT | Plate, Bone, Growth Control, Pediatric, Epiphysiodesis | 2 | 6 | Implant, Life-Sustaining |
| OOL | Electronic Depth Gauge | 2 | 1 | SaMD |
| OSN | Software For Diagnosis/Treatment | 2 | 4 | SaMD, Implant |
| OZI | Internal Hinged Elbow Fixator | 2 | 3 | Implant |
| PBF | Orthopaedic Surgical Planning And Instrument Guides | 2 | 27 | SaMD |
| PLF | Bone Wedge | 2 | 18 | Implant |