Internal Hinged Elbow Fixator

Page Type
Product Code
Definition
The hinged internal fixator is intended to treat joint dislocations, more specifically of the elbow joint. The device is intended to be removed once stability is achieved.
Physical State
The hinged internal fixator consists of titanium and cobalt chromium components
Technical Method
The hinged internal fixator secures the elbow joint by means of a plate and screws on the ulna attached to a pin that is inserted into the humerus.
Target Area
The hinged internal fixator is intended for use in the elbow joint.
Regulation Medical Specialty
Orthopedic
Review Panel
Orthopedic
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
888.3030
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
Yes
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 888.3030 Single/multiple component metallic bone fixation appliances and accessories

§ 888.3030 Single/multiple component metallic bone fixation appliances and accessories.

(a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

(b) Classification. Class II.

Internal Hinged Elbow Fixator

Page Type
Product Code
Definition
The hinged internal fixator is intended to treat joint dislocations, more specifically of the elbow joint. The device is intended to be removed once stability is achieved.
Physical State
The hinged internal fixator consists of titanium and cobalt chromium components
Technical Method
The hinged internal fixator secures the elbow joint by means of a plate and screws on the ulna attached to a pin that is inserted into the humerus.
Target Area
The hinged internal fixator is intended for use in the elbow joint.
Regulation Medical Specialty
Orthopedic
Review Panel
Orthopedic
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
888.3030
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
Yes
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 888.3030 Single/multiple component metallic bone fixation appliances and accessories

§ 888.3030 Single/multiple component metallic bone fixation appliances and accessories.

(a) Identification. Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

(b) Classification. Class II.