LKF · Cannula, Manipulator/Injector, Uterine

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 2

Overview

Product CodeLKF
Device NameCannula, Manipulator/Injector, Uterine
Regulation21 CFR 884.4530
Device ClassClass 2
Review PanelObstetrics/Gynecology
3rd-Party ReviewableYes

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 87)

Showing 20 most recent of 87 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253403FemVue® Controlled Saline-Air Device (FSA-300)Femasys, Inc.Dec 15, 2025SESE
K252260RELIEEV HSG Catheter (HSG7FA1)Li Medical Corporation , Ltd.Nov 26, 2025SESE
K242002FemVue MINI Saline-Air DeviceFemasys, Inc.Nov 22, 2024SESE
K240364RELIEEV Uterine Manipulator Injector (CUMI 5.0)Li Medical Corporation , Ltd.Oct 16, 2024SESE
K241693FemChec Controlled Saline-Air Device (FCD-250)Femasys, Inc.Sep 6, 2024SESE
K222798Rejoni Intrauterine CatheterRejoni, Inc.Dec 16, 2022SESE
K223064ALLY II Uterine Positioning System™ (UPS)CooperSurgical, Inc.Oct 28, 2022SESE
K220202Uterine ElevatOR PRO with OccludOR BalloonThe O R Company Pty, Ltd.Mar 31, 2022SESE
K212505DUMI ManipulatORThe O R Company Pty, Ltd.Jan 10, 2022SESE
K181770Intrauterine Access Balloon Catheter, Selective Salpingography CatheterCook IncorporatedMar 29, 2019SESE
K180300Margolin HSG Cannula, Goldstein Sonohysterography CatheterCook IncorporatedOct 26, 2018SESE
K180291Cook Silicone Balloon HSG CatheterCook IncorporatedOct 26, 2018SESE
K172846Uterine ManipulatorBeijing Hangtian Kadi Technology R&D InstituteJun 26, 2018SESE
K171604Rösch Thurmond Fallopian Tube Catheterization Set, Fallopian Tube Catheterization Set, and Fallopian Tube Catheterization Wire Guide with Platinum TipCook IncorporatedFeb 15, 2018SESE
K163214Unicare System, Unicare ManipulatorClearpath Surgical, Inc.Feb 7, 2017SESE
K160217uVue HSG/SHG CatheterCook IncorporatedOct 6, 2016SESE
K153092Ally Uterine Positioning SystemCooperSurgical, Inc.Dec 21, 2015SESE
K150519ManipulatOR PRO, ManipulatORGynetech Pty. , Ltd.Aug 19, 2015SESE
K142545SonoFlow Sonohysterography and Sonohysterosalpingography DeviceCrossbay Medical, Inc.Mar 20, 2015SESE
K143415Air Bubble Based Infuser (ABBI)CooperSurgical, Inc.Feb 26, 2015SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...