FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
CFR Sub-Part
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart C—Cardiovascular Monitoring Devices
CFR Sub-Part
Subpart C—General Hospital and Personal Use Monitoring Devices
CFR Sub-Part
Subpart D—Pathology Instrumentation and Accessories
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—General Hospital and Personal Use Therapeutic Devices
CFR Sub-Part
BRZ
Set, Blood Transfusion
2
Product Code
BWJ
Locator, Acupuncture Point
2
Product Code
CAK
Microfilter, Blood Transfusion
2
Product Code
DWL
Stocking, Medical Support (To Prevent Pooling Of Blood In Legs)
2
Product Code
FMF
Syringe, Piston
2
Product Code
FMG
Stopcock, I.V. Set
2
Product Code
FMI
Needle, Hypodermic, Single Lumen
2
Product Code
FMS
Bed, Pediatric Open Hospital
2
Product Code
FMT
Warmer, Infant Radiant
2
Product Code
FMZ
Incubator, Neonatal
2
Product Code
FNG
Lift, Patient, Ac-Powered
2
Product Code
FNJ
Bed, Manual
1
Product Code
FNK
Bed, Hydraulic, Adjustable Hospital
1
Product Code
FNL
Bed, Ac-Powered Adjustable Hospital
2
Product Code
FNM
Mattress, Air Flotation, Alternating Pressure
2
Product Code
FNN
Nipple, Lambs Feeding
1
Product Code
FOD
Device, Occlusion, Umbilical
1
Product Code
FOH
Mattress, Water, Temperature Regulated
1
Product Code
FOK
Pad, Neonatal Eye
1
Product Code
FOS
Catheter, Umbilical Artery
2
Product Code
FOZ
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
2
Product Code
K
25
2398
SURFLO Hybria Closed System Safety IV Catheter
2
Cleared 510(K)
K
25
2677
Polyshield Safety IV Catheters
2
Cleared 510(K)
K
25
1422
BD Saf-T-Intima™ Subcutaneous Catheter System
2
Cleared 510(K)
K
24
3403
BD Nexiva™ Closed IV Catheter System
2
Cleared 510(K)
K
25
1155
BD Cathena™ Safety IV Catheter
2
Cleared 510(K)
K
25
1654
BD Insyte™ Autoguard™ Shielded IV Catheter, BD Insyte™ Autoguard™ BC Shielded IV Catheter and BD Insyte™ Autoguard™ BC Pro Shielded IV Catheter
2
Cleared 510(K)
K
25
0682
BD Nexiva™ Diffusics™ Closed IV Catheter System and BD Nexiva™ Diffusics™ Closed IV Catheter System with BD MaxZero™ Needle-free Connector
2
Cleared 510(K)
K
24
3105
Ruby Intravascular Catheter
2
Cleared 510(K)
K
25
0292
OSPREY Midline Closed IV Catheter System (OspreyEDC-F20)
2
Cleared 510(K)
K
24
4059
HydroMID 5F Dual Lumen Midline Catheter - Basic Kit (70006102); HydroMID 5F Dual Lumen Midline Catheter - Max Barrier Kit (70006104); HydroMID 5F Dual Lumen Midline Catheter - Mobile Max Barrier Kit (90006104)
2
Cleared 510(K)
K
24
3599
Arrow™ Endurance™ Extended Dwell Peripheral Catheter System (EDC-00818)
2
Cleared 510(K)
K
24
2281
Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00620); Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00622); Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00820); Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00822)
2
Cleared 510(K)
K
24
1115
SV Spectrum MRC Central Venous Catheter; SV Spectrum MR Central Venous Catheter; SV Central Venous Catheter
2
Cleared 510(K)
K
24
0359
PowerGlide Pro™ Midline Catheter
2
Cleared 510(K)
K
24
1845
Introcan Safety® 2 IV Catheter
2
Cleared 510(K)
K
23
3106
AccuCath Ace™ Intravascular Catheter
2
Cleared 510(K)
K
23
2234
Nouvo Safety Set
2
Cleared 510(K)
K
23
3529
BD Nexiva™ Diffusics™ Closed IV Catheter System with BD MaxZero™ Needle-free Connector
2
Cleared 510(K)
K
23
1239
Nexiva™ Closed IV Catheter System with NearPort™ IV Access
2
Cleared 510(K)
K
23
1401
Polysafety BC, Polysafety BC Adva, Polywin Safety, Polywin Safety Adva
2
Cleared 510(K)
K
22
3788
The MedSource TrueSafe Blood Control I.V. Safety Catheter, and the MedSource ClearSafe Blood Control I.V. Safety Catheter
2
Cleared 510(K)
K
23
1626
OSPREY Closed IV Catheter System (OspreyV2)
2
Cleared 510(K)
K
22
1827
Mais Central Venous Catheter
2
Cleared 510(K)
K
23
0616
Polyguard and Polyshield Safety IV Catheters
2
Cleared 510(K)
K
22
3018
OSPREY PERIPHERAL IV Catheter System
2
Cleared 510(K)
K
22
3648
Cook® Spectrum® 2 MRC Central Venous Catheter
2
Cleared 510(K)
K
22
0772
HydroMID 4F Single Lumen Midline Catheter
2
Cleared 510(K)
K
21
0929
MagiCath II
2
Cleared 510(K)
K
21
2370
Leaderflex Mini and Leaderflex Nano
2
Cleared 510(K)
K
22
0756
Introcan Safety 2 IV Catheter
2
Cleared 510(K)
K
22
0626
Introcan Safety IV Catheter
2
Cleared 510(K)
K
22
0584
BD Cathena Safety IV Catheter
2
Cleared 510(K)
K
21
0037
Pluski Safe 1 Safety IV Catheter
2
Cleared 510(K)
K
21
3664
B. Braun Introcan Safety 2 IV Catheter
2
Cleared 510(K)
K
21
3085
Introcan Safety 3 Closed IV Catheter
2
Cleared 510(K)
K
20
2060
Disposable IV catheter
2
Cleared 510(K)
K
20
0891
BD Intima II Closed IV Catheter System, BD Intima II PLUS Closed IV Catheter System
2
Cleared 510(K)
K
20
3069
HydroMID
2
Cleared 510(K)
K
20
1075
BD Insyte Autoguard Shielded IV Catheter, BD Insyte Autoguard BC Shielded IV Catheter, BD Insyte Autoguard BC Pro Shielded IV Catheter
2
Cleared 510(K)
K
19
3158
ACENT™ Central Venous Catheter
2
Cleared 510(K)
K
20
1717
BD Cathena Safety IV Catheter
2
Cleared 510(K)
K
20
0373
Deltaven Fast Flash Closed I.V. Catheter Systems
2
Cleared 510(K)
K
19
3278
MedSource CathMED IV Catheter
2
Cleared 510(K)
K
19
2230
MF SAFECATH
2
Cleared 510(K)
K
20
0266
BD Centro Vena Acute Central Line (7 French Dual Lumen)
2
Cleared 510(K)
K
19
2676
Introcan Safety 2 IV Catheter 18-24 gauge
2
Cleared 510(K)
K
20
0263
Health Line CT Midline Catheter
2
Cleared 510(K)
K
19
2493
BD Cathena (TM) Safety IV Catheter
2
Cleared 510(K)
K
19
2533
Health Line CT CVC
2
Cleared 510(K)
K
19
0855
BD Acute Central Line
2
Cleared 510(K)
K
19
0001
Supercath 5
2
Cleared 510(K)
K
19
1232
AccuCath Ace Intravascular Catheter
2
Cleared 510(K)
K
18
2252
Cook Unimpregnated Central Venous Catheter
2
Cleared 510(K)
K
18
3399
BD Nexiva Closed IV Catheter System
2
Cleared 510(K)
K
18
2870
Introcan Safety 3 Closed IV Catheter
2
Cleared 510(K)
K
18
2538
Merit RadialFlo Arterial Catheter
2
Cleared 510(K)
K
17
2496
SUPERCATH 5 (26G)
2
Cleared 510(K)
K
17
1530
Deltaven XiV Max, Deltaven XiV Max FF
2
Cleared 510(K)
K
17
3354
BD Nexiva Diffusics Closed IV Catheter Systems
2
Cleared 510(K)
K
17
2506
BD Cathena Safety IV Catheter
2
Cleared 510(K)
K
17
2204
BD Intima II PLUS Closed IV Catheter System
2
Cleared 510(K)
K
16
3358
Introcan Safety 3 Closed IV Catheter
2
Cleared 510(K)
K
17
0336
BD Nexiva Closed IV Catheter System (Single Port) with MaxZero Needleless Connector
2
Cleared 510(K)
K
16
1681
Nipro SafeTouch IV Catheter
2
Cleared 510(K)
K
17
0283
BD Nexiva Diffusics Closed IV Catheter System
2
Cleared 510(K)
K
16
3513
Arrow Endurance Extended Dwell Peripheral Catheter System
2
Cleared 510(K)
K
16
2894
AccuCath Intravascular Catheter
2
Cleared 510(K)
K
16
1779
MedSource TrueSafe Safety IV Catheter, MedSource TrueSafe Comfort Safety IV Catheter
2
Cleared 510(K)
K
16
2377
PowerGlide Pro Midline Catheter
2
Cleared 510(K)
K
16
1866
BioFlo Midline Catheter
2
Cleared 510(K)
K
16
1777
BD Nexiva and BD Nexiva Diffusics Closed IV Catheter Systems
2
Cleared 510(K)
K
16
0592
SUPERCATH 6
2
Cleared 510(K)
K
16
0235
ViaValve Safety I.V. Catheter
2
Cleared 510(K)
K
15
3280
PowerGlide Pro Midline Catheter
2
Cleared 510(K)
K
16
0374
20G x 1.25 NovaCath Secure IV Catheter System, 24G x 0.56 NovaCath Secure IV Catheter System
2
Cleared 510(K)
K
15
3298
AccuCath Intravascular Catheter
2
Cleared 510(K)
K
15
2272
Arrow Endurance Extended Dwell Peripheral Catheter System
2
Cleared 510(K)
K
15
1698
BD Angiocath IV Catheter, BD Insyte IV Catheter
2
Cleared 510(K)
K
15
0611
MedSource ClearSafe Safety IV Catheter
2
Cleared 510(K)
K
15
1513
Arrow Endurance Extended Dwell Peripheral Catheter System
2
Cleared 510(K)
K
14
2797
I.V. Catheter
2
Cleared 510(K)
K
15
0109
Arrow Pressure Injectable Jugular Axillo-subclavian Central Catheter (JACC) with Sustain Technology
2
Cleared 510(K)
K
15
0407
BioFlo Midline Catheter
2
Cleared 510(K)
K
14
3610
BD INTIMA II CLOSED IV CATHETER
2
Cleared 510(K)
K
14
2136
ACCUCATH MIDLINE CATHETER SYSTEM
2
Cleared 510(K)
K
14
0270
NEXUS MIDLINE CT CATHETER
2
Cleared 510(K)
K
14
1026
LEADERFLEX
2
Cleared 510(K)
K
14
0504
ACCUCATH BC INTRAVASCULAR CATHETER SYSTEM
2
Cleared 510(K)
K
13
3280
TERUMO SURFLO I.V. CATHETER
2
Cleared 510(K)
K
14
1138
SURFLASH SAFETY I.V. CATHETER
2
Cleared 510(K)
K
14
0419
SUPERCATH5
2
Cleared 510(K)
K
14
0136
NIPRO SAFETOUCH PSV SCALP VEIN SET WITH SAFETY DEVICE
2
Cleared 510(K)
K
13
1555
MEDSOURCE IV SAFETY CATHETER
2
Cleared 510(K)
K
13
3856
POWERGLIDE MIDLINE CATHETER
2
Cleared 510(K)
K
13
2153
SAFETOUCH PSV WINGED INFUSION SET WITH/WITHOUT FILTER
2
Cleared 510(K)
K
13
0518
MINI-MIDLINE EXTENDED DWELL SAFETY CATHETER
2
Cleared 510(K)
K
12
1488
JMS SAFE WING CATH (SWC)
2
Cleared 510(K)
K
12
3734
BD NEXIVA DIFFUSICS CLOSED IV CATHETER SYSTEM
2
Cleared 510(K)
K
12
1007
NEO DELTA SELF SAFE T, NEO DELTA SELF SAFE T, NEO DELTA SELF SAFE 1, NEO DELTA SELF SAFE 1
2
Cleared 510(K)
K
12
3267
SURFFLASH(R) PLUS SAFETY I.V. CATHETER
2
Cleared 510(K)
K
12
2544
TERUMO SURFLASH SAFETY I.V. CATHETER
2
Cleared 510(K)
K
12
0839
NOVACATH SECURE IV CATHETER SYSTEM-18G
2
Cleared 510(K)
K
11
1939
M/29TM - PRESSURE INJECTABLE
2
Cleared 510(K)
K
12
1073
POWERGLIDE MIDLINE CATHETER
2
Cleared 510(K)
K
11
3622
ORION II CT CVC
2
Cleared 510(K)
K
11
3565
MULTI-MED CENTRAL VENOUS CATHETERS (CVCS), WITH AND WITHOUT HEPARIN VANTEX CENTRAL VENOUS CATHETERS (CVCS), WITH HEPARIN
2
Cleared 510(K)
K
11
2290
SUPERCATH Z3V
2
Cleared 510(K)
K
11
3700
VIAVALVE SAFETY IV CATHETER
2
Cleared 510(K)
K
11
3429
SAFETOUCH PSV WINGED INFUSION SET, AND SET WITH FILTER
2
Cleared 510(K)
K
12
0337
I-PORT ADVANCE INJECTION PORT
2
Cleared 510(K)
K
11
2542
YOMURA SAFETY I.V. CATHETER
2
Cleared 510(K)
K
11
0794
AMECATH CVC AND AMECATH PRESSURE CVC SHORT TERM SINGLE AND MULTI-LUMEN CATHERIZATION KITS
2
Cleared 510(K)
K
11
1366
BD NEXIVA DIFFUSICS CLOSED IV CATHETER SYSTEM
2
Cleared 510(K)
K
11
2347
RAPID INTRAVASCULAR CATHETER START SYSTEM 22 GAUGE / 20 GAUGE / 18 GAUGE
2
Cleared 510(K)
K
11
1236
INTROCAN SAFETY (R) 3 CLOSED IV CATHETER 18GA X 1-3/4 (45MM) AND 18GA X 1-1/4 (32MM) / 20GA X 1-1/4 (32MM) / 20GA X 1
2
Cleared 510(K)
K
11
0443
BD INSYTE AUTOGUARD BC
2
Cleared 510(K)
K
10
2520
BD NEXIVA CLOSED IV CATHETER SYSTEM
2
Cleared 510(K)
K
10
0775
BD INTIMA II CLOSED IV CATHETER
2
Cleared 510(K)
K
10
0974
SPECTRUM TURBO-JECT PICC SET
2
Cleared 510(K)
K
10
0282
TERUMO SURSHIELD- PUR SAFETY I.V. CATHETER
2
Cleared 510(K)
K
09
3546
SUPERCATH 5 MODEL SP120-XX-XX, SP125-XX-XX
2
Cleared 510(K)
K
09
1709
MULTI-MED CENTRAL VENOUS CATHETERS, MODELS: M3720HKIC, M4820HKIC
2
Cleared 510(K)
K
09
2629
SNM FIRMGRIP
2
Cleared 510(K)
K
08
3429
I.V. CATHETER, MODELS: TYPE I, TYPE Y, TYPE STRAIGHT
2
Cleared 510(K)
K
09
0973
TERUMO SURSHIELD SAFETY I.V. CATHETER (18G X 51MM & 20G X 51MM SIZES)
2
Cleared 510(K)
K
08
2997
TERUMO HYBRIA CLOSED SYSTEM SAFETY I.V. CATHETER
2
Cleared 510(K)
K
08
1953
SUPERCATH 5
2
Cleared 510(K)
K
09
0502
NOVA SAFE SCALP VEIN BLOOD COLLECTION SET
2
Cleared 510(K)
K
09
0122
NUOVOGUARD
2
Cleared 510(K)
K
08
3454
NUOVOCATH
2
Cleared 510(K)
K
08
1420
VANISHPOINT I.V. CATHETER
2
Cleared 510(K)
K
08
0793
FIRMGRIP
2
Cleared 510(K)
K
08
2362
SURSHIELD SAFETY I.V. CATHETER
2
Cleared 510(K)
K
08
1113
COOK AND COOK SPECTRUM CENTRAL VENOUS CATHETERS
2
Cleared 510(K)
K
08
1690
SPECTRUM TURBO-JECT PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
07
3471
VANTAGECATH INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
07
3520
ANGIOTECH CVC
2
Cleared 510(K)
K
07
3241
VASCULAR PATHWAYS RIVS RAPID INTRAVASCULAR CATHETER START SYSTEM
2
Cleared 510(K)
K
07
0705
MODIFICATION TO: LATEX-FREE BIONECTOR, MODEL# 896.019, 896.039
2
Cleared 510(K)
K
07
2419
ADVANTIV SAFETY I.V. CATHETER
2
Cleared 510(K)
K
07
1382
SCM CATH ( SIZES ARE VARYING BETWEEN 16G X 2'' AND 24G X 3/4'' ), MODEL 1.50, 1.77,1.88',2, 1.25, 1.50, 1.77,
2
Cleared 510(K)
K
07
1538
ARROW, ARROWG+ARD AND ARROWG+ARD BLUE PLUS PRESSURE INJECTABLE CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
07
0020
COMCASET-P SAFETY IV CATHETER
2
Cleared 510(K)
K
07
0451
ABLE CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
06
3469
MEDICAN ALPHA
2
Cleared 510(K)
K
06
1250
MULTICATH EXPERT
2
Cleared 510(K)
K
06
2108
COMCASET SAFETY IV CATHETER
2
Cleared 510(K)
K
06
0341
SHERLOCK TIP LOCATION SYSTEM (TLS)
2
Cleared 510(K)
K
05
2564
VYGON LEADER-FLEX
2
Cleared 510(K)
K
05
2881
VYGON LATEX FREE BIONECTOR
2
Cleared 510(K)
K
06
0174
SPECTRUM FIVE LUMEN CENTRAL VENOUS CATHETER SET, MODEL C-UQLM10.0-ABRM
2
Cleared 510(K)
K
04
2504
CATHY STERILE DISPOSABLE I.V. CANNULA WITH CATHETER
2
Cleared 510(K)
K
05
3120
STERILE FIELD SALINE AND HEPARIN LOCK FLUSH SYRINGES
2
Cleared 510(K)
K
05
1355
VANISHPOINT I.V. CATHETER
2
Cleared 510(K)
K
05
2389
I-PORT
2
Cleared 510(K)
K
05
0114
SUPERCATH Z3V
2
Cleared 510(K)
K
04
3446
EMMEBI CENTRAL VENOUS CATHETER KIT WITH LESTEP SAFETY INTRODUCER
2
Cleared 510(K)
K
04
2862
BD ONECATH
2
Cleared 510(K)
K
03
3843
SPECTRUM CENTRAL VENOUS CATHETER WITH OR WITHOUT HYDROPHILIC COATING
2
Cleared 510(K)
K
04
1345
PROTECTIV JELCO SAFETY I.V. CATHETER, MODEL 3600 SERIES
2
Cleared 510(K)
K
04
0427
FIBREX CATHETER PATENCY DEVICE
2
Cleared 510(K)
K
03
2292
BIOTEQUE A.V. FISTULA NEEDLE SET WITH SAFETY FLEX
2
Cleared 510(K)
K
03
2843
NEXIVA CLOSED IV CATHETER SYSTEM
2
Cleared 510(K)
K
03
2274
COOK FIVE LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
03
3500
BD CAREFLOW CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
03
3853
MODIFICATION TO V-CATH POLY PICC
2
Cleared 510(K)
K
03
3250
EDWARDS LIFESCIENCES VANTEX CENTRAL VENOUS CATHETERS WITH THERMISTOR
2
Cleared 510(K)
K
03
2417
HEPARIN LOCK FLUSH SYRINGE
2
Cleared 510(K)
K
03
2777
MODIFICATION TO: NIPRO SAFE TOUCH SAFETY FISTULA NEEDLE
2
Cleared 510(K)
K
03
2962
AC 3 LUMEN CENTRAL VENOUS ACCESS KIT WITH ARROWG+ARD ANTIMICROBIAL SURFACE
2
Cleared 510(K)
K
03
0479
JMS SYSLOC A.V. FISTULA NEEDLE SET, JMS SYSLOC APHERESIS NEEDLE SET
2
Cleared 510(K)
K
02
4007
SUNDER CENTRAL VENOUS CATHETER KIT, MODELS SD-3L55F30J AND SD-3L70F30J
2
Cleared 510(K)
K
02
1557
SPECTRUM SILICONE CATHETER
2
Cleared 510(K)
K
02
3253
PEDIATRIC CENTRAL VENOUS CATHETER KIT
2
Cleared 510(K)
K
03
0571
ACUVANCE PLUS SAFETY IV CATHETER, PROTECTIV PLUS SAFETY IV CATHETER, OPTIVA IV CATHETER
2
Cleared 510(K)
K
02
1130
SPECATH CENTRAL VENOUS CATHETER KITS
2
Cleared 510(K)
K
02
2756
NIPRO BIO-FLEX CATHETER
2
Cleared 510(K)
K
02
2099
SAFE-T-PEEL SAFETY NEEDLE/INTRODUCER, MODELS 350-300 S, 360-300'S,380-300'S,390-300'S
2
Cleared 510(K)
K
02
0785
INTROCAN SAFETY IV CATHETER
2
Cleared 510(K)
K
01
3182
TRIPLE LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
02
1139
TRULINE REINFORCED VALVED INFUSION CATHETER
2
Cleared 510(K)
K
00
2142
SALINE IV FLUSH SYRINGE
2
Cleared 510(K)
K
01
1967
BD PRE-FILLED HEPARIN LOCK FLUSH IN 0.9% SODIUM CHLORIDE INJECTION, USP SYRINGE
2
Cleared 510(K)
K
01
3556
MONOJECT PREFILL HEPARIN LOCK FLUSH SYRINGE
2
Cleared 510(K)
K
01
3800
INSYTE, ANGIOCATH, INSYTE AUTOGUARD, ANGIOCATH AUTOGUARD, AUTOGUARD PRO, INTIMA, AND SAF-T-INTIMA INTRAVASCULAR CATHETE
2
Cleared 510(K)
K
01
3287
NIPRO SAFELET CATH
2
Cleared 510(K)
K
01
3073
INSYTE, ANGIOCATH, INSYTE AUTOGUARD, ANGIOCATH AUTOGUARD, AUTOGUARD PRO, INTIMA AND SAF-T-INTIMA INTRAVASCULAR CATHETERS
2
Cleared 510(K)
K
01
1937
TRULINE INFUSION CATHETERS
2
Cleared 510(K)
K
01
2128
PROTECTIV ACUVANCE IV CATHETER SYSTEM
2
Cleared 510(K)
K
01
1982
0.9% SODIUM CHLORIDE INJECTION, USP BD PRE-FILLED FLUSH SYRINGE
2
Cleared 510(K)
K
01
1860
KEYST0NE MEDICAL PICC CATHETER
2
Cleared 510(K)
K
01
1297
NIPRO SAFETOUCH SCALP VEIN AND BLOOD COLLECTION SET
2
Cleared 510(K)
K
01
0410
JMS APHERESIS NEEDLE WING EATER, MODEL 14G-18G
2
Cleared 510(K)
K
01
0406
JMS A.V. FISTULA NEEDLE SET WING EATER, MODEL 14G-18G
2
Cleared 510(K)
K
00
3187
VACUCATH I.V. CATHETER INTRODUCTER
2
Cleared 510(K)
K
00
3553
0.9% SODIUM CHLORIDE INJECTION, USP BD PRE-FILLED FLUSH SYRINGE
2
Cleared 510(K)
K
01
0021
MEDCOMP QUAD LUMEN, 8.5F X 20CM, MODEL MC4L-8S
2
Cleared 510(K)
K
01
0034
DOUBLE LUMEN URETHANE PICC LINE, MODEL UPICDS-
2
Cleared 510(K)
K
00
3245
HEPARIN LOCK FLUSH SYRING 10 USP UNITS/ML, HEPARIN LOCK FLUSH SYRINGE, 100 USP UNITS/ML
2
Cleared 510(K)
K
00
2786
BIOSENSORS CENTRAL VENOUS CATHETER KITS
2
Cleared 510(K)
K
00
1795
THE AVITRO LLC, 10 AND 100 USO UNITS/ML HEPARIN SODIUM VAFD
2
Cleared 510(K)
K
00
0632
0.9% SODIUM CHLORIDE VASCULAT ACCESS DEVICE
2
Cleared 510(K)
K
00
0997
ZORTRAN DETECTOR
2
Cleared 510(K)
K
00
1616
MODIFICATION TO SYRINGE PREFILLED WITH 0.9% SODIUM CHLORIDE
2
Cleared 510(K)
K
00
2033
BD INSYTE AUTOGUARD -P AND BD INSYTE AUTOGUARD -P WINGED IV CATHETERS
2
Cleared 510(K)
K
99
2532
VANTEX CENTRAL VENOUS CATHETER WITH OLIGON MATERIAL WITH OR WITHOUT AMC THROMBOSHIELD COATING
2
Cleared 510(K)
K
99
3518
MEDEFIL'S HEPARIN I.V. FLUSH SYRINGE, IN VARIOUS FILL SIZES - 1 ML FILL IN 3 ML SYRINGE LL; 1 ML FILL IN 6 ML SYRINGE LL
2
Cleared 510(K)
K
00
0665
TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER
2
Cleared 510(K)
K
99
2732
STERILE WATER & STERILE 0.9% SODIUM CHLORIDE
2
Cleared 510(K)
K
00
0235
INSYTE CATHETER, INSYTE AUTOGUARD CATHETER
2
Cleared 510(K)
K
00
0087
MARHUKAR TRIPLE LUMEN CATHETER, MODEL 12 FR
2
Cleared 510(K)
K
99
3691
ARROWG +ARD BLUE PLUS ANTIMICROBIAL MULTI-LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
98
2558
BD PREEFILE NORMAL SALINE FLUSH SYRINGE FLUSH SYRINGE
2
Cleared 510(K)
K
99
3515
MEDEFIL'S NORMAL SALINE FLUSH SYRINGE, IN VARIOUS FILL SIZES - 1 ML FILL IN 3 ML SYRINGE LL; 1 ML FILL IN 6 ML SYRINGE L
2
Cleared 510(K)
K
99
0390
HEPARIN IV FLUSH SYRINGE, 10 U/ML \
2
Cleared 510(K)
K
99
0308
ROCAP HEPARIN IV FLUSH SYRINGE, 100U/ML
2
Cleared 510(K)
K
98
4590
0.9% SODIUM CHLORIDE FLUSH SYRINGE
2
Cleared 510(K)
K
99
2198
URETHANE PICC LINE MODEL UPICS-
2
Cleared 510(K)
K
99
0236
MODIFICATION OF JELCO*,JELCO*-W AND JELCO* PLUS I.V. CATHETERS, CATHLON* I.V. CATHETERS, OPTIVA* I.V. CATHETERS, PROTECT
2
Cleared 510(K)
K
99
1406
TERUMO SURFLO FLEX I.V. CATHETER AND TERUMO SURFLASH I.V. CATHETER
2
Cleared 510(K)
K
98
4614
NORMAL SALINE FLUSH SYRINGE
2
Cleared 510(K)
K
98
4189
ARGON MULTI-LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
98
4059
ANGIOCATH AUTOGUARD CATHETER, INSYTE AUTOGUARD CATHETER
2
Cleared 510(K)
K
98
4055
CLINICATH POLYFLOW POLYURETHANE PERIPHERALLY INSERTED CATHETERS
2
Cleared 510(K)
K
98
2805
INTROCAN SAFETY IV CATHETER
2
Cleared 510(K)
K
97
0736
BRAUN PREFILLED SYRINGE
2
Cleared 510(K)
K
98
3916
V-CATH PICC (PERIPHERALLY INSERTED CENTRAL CATHETER)
2
Cleared 510(K)
K
98
3409
V-CATH PICC (PERIPHERALLY INSERTED CENTRAL CATHETER) SEE APPENDIX 1
2
Cleared 510(K)
K
98
0566
VAXESS PERIPHERALLY INSERTED CENTRAL CATHETER
2
Cleared 510(K)
K
98
1905
STERILE SALINE SOLUTION 0.9%- CATALOG NO, 10290, STERILE WATER- CATALOG NO. 10291
2
Cleared 510(K)
K
97
4015
ARGYLE QUICK- PICC PERIPHERALLY INSERTED CENTRAL CATHETER- PICC TRAYS, ARGYLE QUICK- PICC PERIPHERALLY INSERTED CENTRAL
2
Cleared 510(K)
K
97
3561
MEDCOMP TRI-FLOW SOFT TIP TRIPLE LUMEN CATHETER 11.5F X 12CM, MEDCOMP TRI-FLOW SOFT TIP TRIPLE LUMEN CATHETER 11.5F X 1M
2
Cleared 510(K)
K
98
1382
PASV DUAL LUMEN PERIPHERALLY INSERTED MIDLINE CATHETER MODEL NUMBER MIDLINE-NUMEROUS
2
Cleared 510(K)
K
98
1368
PASV DUAL LUMEN PERIPHERALLY INSERTED CENTRAL CATHETER (PICC) MODEL NUMBER PIC-NUMEROUS
2
Cleared 510(K)
K
98
0493
I.V. CATHETER SYSTEM
2
Cleared 510(K)
K
97
4764
INTROSYTE CATHETER
2
Cleared 510(K)
K
97
4543
L-CATH MODIFIED SELDINGER TECHNIQUE INSERTION/CATHETER EXCHANGE KIT PE-MST24-24 GA. KIT, L-CATH MODIFIED SELDINGER
2
Cleared 510(K)
K
97
1339
INSYTE, INSYTE-W, INSYTE AUTOGUARD CATHETERS
2
Cleared 510(K)
K
97
1990
GESCO PER-Q-CATH PICC CATHETERS
2
Cleared 510(K)
K
97
1991
GESCO PER-Q-CATH MIDLINE CATHETERS
2
Cleared 510(K)
K
97
0864
ARROW-HOWES LARGE BORE MULTI-LUMEN CENTRAL VENOUS CATHETERS
2
Cleared 510(K)
K
97
2262
FIRST PICC CATHETER
2
Cleared 510(K)
K
97
2264
FIRST MIDCATH CATHETER
2
Cleared 510(K)
K
97
2263
FIRST PICC CATHETER WITH DUAL LUMENS
2
Cleared 510(K)
K
97
2254
FIRST MIDCATH CATHETER
2
Cleared 510(K)
K
96
3196
VYGON UMBILICAL CATHETHER INSERTION TRAY
2
Cleared 510(K)
K
96
2577
ARROWGARD BLUE QUAD-LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
97
0669
AEROQUIP SAFESTART IV CATHETER
2
Cleared 510(K)
K
97
0644
AEROQUIP SAFESTART (TM) IV CATH (TM) SYSTEM
2
Cleared 510(K)
K
96
0764
SAFE-CATH
2
Cleared 510(K)
K
96
4966
V-CATH
2
Cleared 510(K)
K
96
1552
CVP POLYURETHANE CATHETER
2
Cleared 510(K)
K
96
4049
FIRST MIDCATH CATHETER WITH DUAL LUMENS
2
Cleared 510(K)
K
96
4048
FIRST MIDCATH CATHETER KIT
2
Cleared 510(K)
K
96
4050
FIRST MIDCATH CATHETER
2
Cleared 510(K)
K
96
2226
PROTECTIV 2000 I.V. CATHETER SAFETY SYSTEM
2
Cleared 510(K)
K
95
3252
DISPOSABLE SCALP VEIN INFUSION SET
2
Cleared 510(K)
K
96
3867
NEO-CARE CATHETERIZATION TRAY
2
Cleared 510(K)
K
96
2938
EXCELSIOR DISPOSABLE SYRINGE W/NORMAL SALINE (.9% SODIUM CHLORIDE)
2
Cleared 510(K)
K
95
3811
MEDCOMP P-CATH
2
Cleared 510(K)
K
95
3805
0.9% SODIUM CHLORIDE DILUENT IN PLASTIC SYRINGE
2
Cleared 510(K)
K
95
4112
VYGON LIFEVAC MID-LINE TRAY
2
Cleared 510(K)
K
95
1620
MIDMARK MIDLINE CATHETER
2
Cleared 510(K)
K
96
0051
NIPRO SAFELET CATH
2
Cleared 510(K)
K
95
4428
SOLOPICC 24 (60CM) 20GA CATHETER
2
Cleared 510(K)
K
95
5839
MULTI-MED MULTI-LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
96
0013
MDC SAFE STEP SAFETY I.V. CATHETER SYSTEM
2
Cleared 510(K)
K
95
0118
ABRM CATHETER
2
Cleared 510(K)
K
95
4887
STERILE WATER O.9% STERILE SALINE
2
Cleared 510(K)
K
95
3335
MICRO THERAPEUTICS VARIABLE INFUSION LENGTH CATHETER
2
Cleared 510(K)
K
95
5053
NIPRO SCALP VEIN SET (DISPOSABL PSV SET)
2
Cleared 510(K)
K
95
3120
VITAL SIGNS HEPARIN VASCULAR ACCESS FLUSH DEVICE
2
Cleared 510(K)
K
95
2645
VITAL SIGNS SALINE VASCULAR ACCESS FLUSH DEVICE
2
Cleared 510(K)
K
94
6170
COMFORT-Q SUBCUTANEOUS INJECTION SETS
2
Cleared 510(K)
K
95
2058
STERILE V.A.D. (VASCULAR ACCESS DEVICES) ACCESS KIT, DISPOSABLE
2
Cleared 510(K)
K
93
2946
WALLACE IV CANNULA
2
Cleared 510(K)
K
93
2947
WALLACE Y-CAN
2
Cleared 510(K)
K
95
2861
ANGIOCATH & INSYTE AUTOGUARD CATHETERS
2
Cleared 510(K)
K
95
2757
ANGIOCATH, NOVBALON, ANGIO-SET INTRAVASCULAR & ANGIOCATH INTRODUCTION DRAINAGE CATHETER
2
Cleared 510(K)
K
95
2256
PICC LINE KIT
2
Cleared 510(K)
K
94
1678
BIONECTOR
2
Cleared 510(K)
K
95
0284
SIMS DELTEC, INC. CATHETER REPLACEMENT CONNECTOR
2
Cleared 510(K)
K
94
5053
LF CT HIG PRESSURE CATHETERS
2
Cleared 510(K)
K
95
0301
ANGIOCATH(R) NONVALON(R) AND ANGIO-SET(R) IV CATHETERS
2
Cleared 510(K)
K
94
4302
THE FLEX-SET SUBCUTANEOUS INFUSION SET
2
Cleared 510(K)
K
94
5521
CENTERMARK(R) PICC INSERTION TRAY LANDMARK(R) MIDLINE CATHETER PREP TRAY
2
Cleared 510(K)
K
94
4410
CATCO SILICONE DUAL LUMEN UMBILICAL VESSEL CATHETER
2
Cleared 510(K)
K
94
4367
CATCO POLYURETHANE UMBILICAL VESSEL CATHETER
2
Cleared 510(K)
K
94
4368
CATCO SILICONE UMBILICAL VESSEL CATHETER
2
Cleared 510(K)
K
94
4336
CATCO UMBILICAL VESSEL CATHETER
2
Cleared 510(K)
K
94
4504
CATCO FIRST PICC
2
Cleared 510(K)
K
95
0737
LANDMARK MIDLINE CATHETER
2
Cleared 510(K)
K
94
4968
LANDMARK MIDLINE CATHETER
2
Cleared 510(K)
K
94
3349
MAHURKAR DUAL LUMEN CATHETER
2
Cleared 510(K)
K
94
4660
ACUTE CENTRAL VENOUS ACCESS CATHETER TRAY
2
Cleared 510(K)
K
94
4511
ACUTE CENTRAL VENOUS ACCESS CATHETER (ACVAC)
2
Cleared 510(K)
K
94
2045
INSYTE INTRODUCER CATHETER
2
Cleared 510(K)
K
93
3467
PRN ADAPTER
2
Cleared 510(K)
K
94
0634
MICRO THERAPEUTICS INFUSION CATHETER
2
Cleared 510(K)
K
93
5090
CUFF-CATH
2
Cleared 510(K)
K
94
1417
VITAFLON PLUS/VASCULON
2
Cleared 510(K)
K
94
3023
CVD BULLETT PERIPHERAL INFUSION CATHETER
2
Cleared 510(K)
K
93
2789
ONE-SITE IV CONNECTOR
2
Cleared 510(K)
K
94
0775
INJECTION CAP
2
Cleared 510(K)
K
94
0441
DIAL MEDICAL SUPPLY FISTULA NEEDLE SET
2
Cleared 510(K)
K
94
0385
NAVIGATOR-MP CATHETER LOCATION INSTRUMENT
2
Cleared 510(K)
K
93
0048
SAFE-PICC CATHETER
2
Cleared 510(K)
K
93
1073
CATH-FINDER
2
Cleared 510(K)
K
92
6544
PHARMACIA DELTEC PERIPHERALLY INSERTED VENOUS CATH
2
Cleared 510(K)
K
93
1668
PICC INSERTION TRAY
2
Cleared 510(K)
K
93
1729
I.V. START KIT
2
Cleared 510(K)
K
93
2071
I.V. START KIT
2
Cleared 510(K)
K
93
1027
BULLETT PERIPHERAL INFUSION CATHETER
2
Cleared 510(K)
K
92
6405
.9% NORMAL SALINE TUBE/STERILE WATER TUBE
2
Cleared 510(K)
K
93
3050
CHANGES TO PROTECTIV(TM) & JELCO(TM) WINGED CATH
2
Cleared 510(K)
K
92
3702
INTIMA POINT GUARD INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
92
6097
CYBILNATE(R) UMBILICAL CATHETER
2
Cleared 510(K)
K
92
3323
INTERMITTENT INJECTION SITE
2
Cleared 510(K)
K
92
4968
L-CATH PEEL-AWAY CATHETER SYSTEM
2
Cleared 510(K)
K
91
4378
PERIPHERAL INTERVENOUS CATHETER
2
Cleared 510(K)
K
92
0638
BIO-MATE PIC CATHETER
2
Cleared 510(K)
K
92
1955
QUIK FLOW
2
Cleared 510(K)
K
91
5824
HOLE PUNCH
2
Cleared 510(K)
K
91
4528
SAFEDWEL(R) CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
92
1270
SAFE-DWELL PLUS CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
92
0828
SAFE-PICC PERIPHERALLY INSERTED CENTRAL VENOUS CAT
2
Cleared 510(K)
K
91
4180
DESERET(R) FLOW RESTRICTION VALVE
2
Cleared 510(K)
K
92
0635
E-Z SET/MINICATH INFUSION SETS
2
Cleared 510(K)
K
92
0128
VERSACATH MAINLINE CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
92
0133
VERSACATH SELECTALUMEN INNER CATHETER
2
Cleared 510(K)
K
92
0028
LANDMARK MIDLINE CATHETER
2
Cleared 510(K)
K
91
5065
I.V.IRRIGATION POLE
2
Cleared 510(K)
K
91
2358
LANDMARK ADD-A-LUMEN CATHETER KIT
2
Cleared 510(K)
K
91
2165
LANDMARK DUAL-LUMEN MIDLINE CATHETER SYSTEM
2
Cleared 510(K)
K
91
1251
FLEX-IV
2
Cleared 510(K)
K
91
2158
CENTRAL VENOUS CATHETER DRESSING CHANGE TRAY
2
Cleared 510(K)
K
91
2563
ANGEL WING SAFETY BLOOD COLLECTION AND INFUSION SE
2
Cleared 510(K)
K
90
5415
BRAIDED HIGH PRESSURE CATHETER CONNECTOR
2
Cleared 510(K)
K
91
0566
VERSACATH(TM) MULTILUMEN SYSTEM
2
Cleared 510(K)
K
91
0565
VERSACATH(TM) SELECTALUMEN(TM) W/CONVERSION TRAY
2
Cleared 510(K)
K
91
0564
VERSACATH(TM0 MAINLINE(TM) WITH INTRODUCTION TRAY
2
Cleared 510(K)
K
91
0572
INJECTION CAPS
2
Cleared 510(K)
K
91
0799
LANDMARK VENOUS ACCESS DEVICE
2
Cleared 510(K)
K
90
4558
DUAL LUMEN 5 FR PERIP CENT VEN CATH W/GROSHONG VAL
2
Cleared 510(K)
K
90
5463
GENERAL MEDICAL PROCEDURE KIT/SKIN PREPARATION
2
Cleared 510(K)
K
90
5009
DIGITCARE I.V. START KIT
2
Cleared 510(K)
K
90
4648
SAFE SYTE I.V. CATHETER PLACEMENT UNIT
2
Cleared 510(K)
K
90
3347
SODIUM CHLORIDE SOLUTION
2
Cleared 510(K)
K
90
4150
CATH-FINDER(TM) CATHETER TRACKING SYSTEM
2
Cleared 510(K)
K
90
3545
CAREKITS(TM), IV/CATH/CENT LINE DRESS/TPN/CVP KITS
2
Cleared 510(K)
K
90
4121
VIALON OBTURATOR
2
Cleared 510(K)
K
89
6813
MODIFIED INTRAVENOUS CATHETER
2
Cleared 510(K)
K
90
4122
INSYTE-A ARTERIAL CATHETERIZATION UNIT
2
Cleared 510(K)
K
90
3732
KENDALL SAFETRAK(TM) HIGH FLOW CATHETER
2
Cleared 510(K)
K
90
1701
CENTRAL VENOUS ACCESS CATHETER
2
Cleared 510(K)
K
90
2527
SPLIT-SECOND INTRODUCER
2
Cleared 510(K)
K
89
5597
VAS-CATH TRIFUSION TRIPLE LUMEN INFUSION CATHETER
2
Cleared 510(K)
K
89
5812
SHARGHP INTRAVENOUS CATHETER
2
Cleared 510(K)
K
90
1263
NAVION SMART-WIRE(TM) CATHETER LOCATION SYSTEM
2
Cleared 510(K)
K
90
0056
CATHETER WITH GUIDEWIRE ASSEMBLY DEVICE
2
Cleared 510(K)
K
90
1640
MULTICATH PLACEMENT KIT
2
Cleared 510(K)
K
90
2135
PERCUTANEOUS INTRODUCER KIT
2
Cleared 510(K)
K
90
0263
ANTIMICROBIAL MULTI-LUMEN CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
89
5942
GESCO DUAL LUMEN PER-Q-CATH-DL
2
Cleared 510(K)
K
90
0116
DESERET OPTIMA INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
89
5734
DESERET INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
89
5768
EXEL SAFELET CATHETER
2
Cleared 510(K)
K
89
6774
STREAMLINE VASCULAR ACCESS DEVICE
2
Cleared 510(K)
K
89
4611
CATHETER CARE KITS
2
Cleared 510(K)
K
89
5191
ANTI-THROMBOGENIC COATING FOR CATHETERS
2
Cleared 510(K)
K
89
3546
OPTICALLY CLEAR RADIOPAQUE CATHETER
2
Cleared 510(K)
K
89
4371
NIPRO SAFELET CATH
2
Cleared 510(K)
K
89
3965
PROLONG INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
88
4577
PROCEDURE READY TRAYS
2
Cleared 510(K)
K
89
3003
TOCOLYTIC SITE CARE SUP KIT #1001/100A/CARRY CASE
2
Cleared 510(K)
K
89
1087
TERUMO SURFLO(R) I.V. CATHETER
2
Cleared 510(K)
K
88
4325
SUBCLAVIAN HEMODIALYSIS CATH. W/VITACUFF DEVICE
2
Cleared 510(K)
K
89
0751
ACCI-GUARD(TM) I.V. CATHETER PLACEMENT UNIT
2
Cleared 510(K)
K
89
0435
VITAACCESS CATHETER INTRODUCER KIT
2
Cleared 510(K)
K
88
4806
LUMED EXPANDO-CATH, ACTIV
2
Cleared 510(K)
K
88
4701
CATH-FINDER SYSTEM
2
Cleared 510(K)
K
88
3980
LANDMARK VENOUS ACCESS DRIVE (ADDITIONAL SIZES)
2
Cleared 510(K)
K
88
3866
NEOSOFT UMBILICAL VESSEL CATHETER
2
Cleared 510(K)
K
88
4259
MODIFIED LANDMARK VENOUS ACCESS DEVICE
2
Cleared 510(K)
K
88
3415
VASCULON 2 INTRAVENOUS CANNULA
2
Cleared 510(K)
K
88
1767
VIGGO INSUFLON
2
Cleared 510(K)
K
88
1976
CATHETER, INTRAVASCULAR
2
Cleared 510(K)
K
88
2242
LANDMARK(TM) VENOUS ACCESS DEVICE
2
Cleared 510(K)
K
88
1215
CENTRASIL SILICONE ELASTOMER CENTRAL VENOUS CATH
2
Cleared 510(K)
K
88
1236
TORAY ANTHRON P-U CATHETERS
2
Cleared 510(K)
K
88
1666
HR(TM) INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
88
0260
SAFECATH
2
Cleared 510(K)
K
87
2998
VITAACCESS (TM) CATHETER INTRODUCER SYSTEM
2
Cleared 510(K)
K
87
5082
O.P.C. INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
87
5177
J&J SCALP VEIN INFUSION SETS
2
Cleared 510(K)
K
87
4582
DESERET SPLITTABLE CATHETER
2
Cleared 510(K)
K
87
3050
VASCULAR ACCESS CATHETER W/ANTIMICROBIAL CUFF
2
Cleared 510(K)
K
87
2585
CHURCHILL-CATH
2
Cleared 510(K)
K
87
1546
SAFESIDE(TM) LUMED
2
Cleared 510(K)
K
87
0403
CAVAFIX(R) CENTRAL VENOUS CATHETER KIT W/SUTURE
2
Cleared 510(K)
K
86
4949
INSTRUCTION CHANGE FOR RIGHT ATRIAL/RAAF CATHETER
2
Cleared 510(K)
K
86
2153
ARROW 18GA TWO-LUMEN INTRAVENOUS CATH/23GA NEEDLE
2
Cleared 510(K)
K
86
4038
SUPERCATH I.V. CATHETER
2
Cleared 510(K)
K
86
1725
INTRACATH INTRAVENOUS CATHETER PLACEMENT UNIT
2
Cleared 510(K)
K
86
2130
COMFORT-SET* I.V. CATHETER PLACEMENT UNIT.
2
Cleared 510(K)
K
86
2480
BT CATH (INTRAVASCULAR CATHETER)
2
Cleared 510(K)
K
86
1479
CAVAFIX, CENTRAL VENOUS CATHETER KIT
2
Cleared 510(K)
K
86
1117
ANTHRON CATHETERS & SETS
2
Cleared 510(K)
K
86
1510
MULTILUMEN VIAPIC CENTRAL LINE CATHETER
2
Cleared 510(K)
K
86
0474
STREAM LINE* I.V. CATHETER PLACEMENT UNIT
2
Cleared 510(K)
K
85
3988
FORAN CORP-SURESERT INTRAVENOUS CATHETER PLACE UNI
2
Cleared 510(K)
K
86
1015
ONE TIME HYPERAL & CATHETER DRESSING CHANGE TRAYS
2
Cleared 510(K)
K
85
4308
POLYCATH-H CATHETER
2
Cleared 510(K)
K
86
0256
BRAWN AND GROSHONG CATHETERS
2
Cleared 510(K)
K
86
0290
VIAPIC CENTRAL LINE CATHETER
2
Cleared 510(K)
K
85
4566
TERUMO SURFLO ETFE I.V. CATHETER
2
Cleared 510(K)
K
85
3348
L-CATH EXPANDO CATH
2
Cleared 510(K)
K
85
3701
JELCO & CATHLON IV STRIPED IV CATHETERS-RADIOPAGUL
2
Cleared 510(K)
K
85
1142
TELET-LEX MEDICAL IV CATHETER PLACEMENT
2
Cleared 510(K)
K
85
1981
NO. 5300-3 1/2 FRENCH UMBILICAL VESSEL CATH. ETC.
2
Cleared 510(K)
K
85
1327
DESERET ARTERIAL CATHETER
2
Cleared 510(K)
K
85
2078
SPECTRUM(TENTATIVE)
2
Cleared 510(K)
K
84
4193
QUINTON INJECTION SEALING CAP
2
Cleared 510(K)
K
85
0887
DRESSING CHANGE KIT
2
Cleared 510(K)
K
85
1101
BIONOMY'S MULTI-LUMEN CENTRAL VENOUS CATHETER-SET
2
Cleared 510(K)
K
85
0276
VIGGO NEOFLON INFUSION CANNULA
2
Cleared 510(K)
K
85
0460
VIGGO SECALON T CATHETER
2
Cleared 510(K)
K
85
0349
VIGGO ARTERIAL CANNULA
2
Cleared 510(K)
K
85
0278
VASCULON I.V. CANNULAE
2
Cleared 510(K)
K
85
0398
NU-CATH EMERGENCY KIT
2
Cleared 510(K)
K
84
2577
CATH-TECH POLYURETHANE UMBILICAL VESS
2
Cleared 510(K)
K
84
2133
EYRTHROCATH DOUBLE-LUMEN CENTRAL VENOUS
2
Cleared 510(K)
K
85
0369
QUINTON WHITE SEALING CAP
2
Cleared 510(K)
K
84
1880
ERYTHROCATH UMBILICAL CATHETER
2
Cleared 510(K)
K
84
3033
DESERET INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
84
4219
DESERET DENTRAL LINE CATHETER
2
Cleared 510(K)
K
84
4113
DESERET SUBCLAVIAN JUGULAR CATHETER SET
2
Cleared 510(K)
K
84
0815
LUER LOCKING ADAPTER(MATERIAL CHANGE)
2
Cleared 510(K)
K
84
0116
DESERET INFANT CENTRAL VENOUS CATHE-
2
Cleared 510(K)
K
84
0862
DESERET CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
84
0355
DESERET MULTILUMEN SUBCLAVIAN JUGULAR
2
Cleared 510(K)
K
84
0183
DESERET MULTILUMEN SUBCLAVIAN JUGULAR
2
Cleared 510(K)
K
83
4227
DESERET SUBCLAVIAN JUGULAR CATH. SET
2
Cleared 510(K)
K
83
4255
PBC SCALP VEIN SET
2
Cleared 510(K)
K
83
4073
CENTRAL VEIN CATHERIZATION TRAY CC-20
2
Cleared 510(K)
K
83
4393
DESERET NEONATAL CATHETER SET
2
Cleared 510(K)
K
83
4480
INJECTION CAP
2
Cleared 510(K)
K
83
3079
CENTRACATH #130,135 & 137-HEMOCATH #
2
Cleared 510(K)
K
83
3657
ANGIO-SET INTRAVENOUS CATH. SET
2
Cleared 510(K)
K
83
2558
RELEASE OF ETHYLENE OXIDE-STERILIZ. DEV
2
Cleared 510(K)
K
83
3135
INTRACATH INTRAVENOUS CATHETER UNIT
2
Cleared 510(K)
K
83
3091
DESERET SUBCLAVIAN JUGULAR CATH-SET
2
Cleared 510(K)
K
83
3092
DESERET ANGIO-GUIDE LARGE VEIN CATH.
2
Cleared 510(K)
K
83
2624
TOP VENULA I.V. CATHETER SET
2
Cleared 510(K)
K
83
0541
INJECTION SEALING CAP 13791
2
Cleared 510(K)
K
83
0972
I.V. CATHETER PLACEMENT UNIT POLYURETH
2
Cleared 510(K)
K
83
0765
WINGED CATHETER
2
Cleared 510(K)
K
83
0573
PRE VUE
2
Cleared 510(K)
K
83
0539
INTRAVASCULAR CATHETER SET
2
Cleared 510(K)
K
82
3565
MULTI-LUMEN INTRAVENOUS CATHETER
2
Cleared 510(K)
K
82
3351
CENTRAL VENOUS CATHETER
2
Cleared 510(K)
K
82
2776
TEFLON CANNULA
2
Cleared 510(K)
K
82
3017
INTRAVENOUS CATHETER PLACEMENT UNIT &
2
Cleared 510(K)
K
82
2023
DESERET SUBCLAVIAN JUGULAR CATH. SET
2
Cleared 510(K)
K
82
1929
SUBCLAVIAN
2
Cleared 510(K)
K
82
1679
LEONARD/NORTON HYPERALIMENTATION CATHET.
2
Cleared 510(K)
K
82
1699
DESERET SUBCLAVIAN JUGULAR CATHETER SET
2
Cleared 510(K)
K
82
1577
DESERET ANGIO GUIDE
2
Cleared 510(K)
K
82
1371
DESERET SUBCLAVIAN JUGULAR CATHETER SET
2
Cleared 510(K)
K
82
1372
DESERET INTRACATH INTRAVENOUS CATHETER
2
Cleared 510(K)
K
81
3374
NUTRICATH
2
Cleared 510(K)
K
81
3396
VERSCHLUBSTOPFEN COMB-CLOSING STOPPER
2
Cleared 510(K)
K
81
3345
CRITIKON I.V. CATHETER PLACEMENT UNIT
2
Cleared 510(K)
K
81
2137
B-D HEPARINIZED LONGDWEL I.V. CATHETER
2
Cleared 510(K)
K
81
2159
INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
81
1171
VASCULON II I.V. CATHETER
2
Cleared 510(K)
K
80
3238
INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
80
2918
ANTHRON CATHETER SET
2
Cleared 510(K)
K
80
1537
START IT WITH & WITHOUT I.V. CATH. UNIT
2
Cleared 510(K)
K
80
1941
BURRON MICROCATH INTRA. CATH. PLACEMENTT
2
Cleared 510(K)
K
80
1575
L-CATH INTRAVENOUS PLACEMENT UNIT
2
Cleared 510(K)
K
80
1414
ERYTHROCATH INTRAVENOUS CATHETER PLA. U.
2
Cleared 510(K)
K
80
0786
INJECTION SITE, CODE NO. 3100
2
Cleared 510(K)
K
80
0525
MEDICAL COMPONENTS IV CATHETER
2
Cleared 510(K)
K
79
1918
JELCO WINGED INTRAVASCULAR CATHETER
2
Cleared 510(K)
K
79
0914
SILASTIC INTRAVENOUS CATHETER UNIT
2
Cleared 510(K)
K
79
0967
CATHETER METAL HUB/RADIOPAQUE
2
Cleared 510(K)
K
77
2011
WHOLEY OCCLUSION BALLOON CATHETER
2
Cleared 510(K)
K
79
0968
CATHETER METAL HUB/NONRADIOPAQUE
2
Cleared 510(K)
K
78
0350
I.V. START KIT
2
Cleared 510(K)
K
78
0105
NEEDLE CONNECTING SET, BLUNT
2
Cleared 510(K)
K
77
2354
I.V. CATHETER
2
Cleared 510(K)
K
77
1381
IV CATHETER HUB
2
Cleared 510(K)
K
77
1573
DUO-CATH FEMORAL
2
Cleared 510(K)
K
77
0751
CATHETERS, OVER-THE-NEEDLE
2
Cleared 510(K)
K
77
0510
CANNULA, INTRAVENOUS, TEFLON
2
Cleared 510(K)
K
77
0511
CANNULA, INTRAVENOUS, HEPARINIZED
2
Cleared 510(K)
K
77
0181
I.V. CATHETER PLACEMENT UNIT
2
Cleared 510(K)
K
77
0403
CATHETER-THRU-NEEDLE DEVICE
2
Cleared 510(K)
K
76
0319
KIT, CATHETER
2
Cleared 510(K)
K
76
0163
CATHETER, INTRAVASCULAR (MEDICUT T)
2
Cleared 510(K)
FPA
Set, Administration, Intravascular
2
Product Code
FPB
Filter, Infusion Line
2
Product Code
FPK
Tubing, Fluid Delivery
2
Product Code
FPL
Incubator, Neonatal Transport
2
Product Code
FQH
Lavage, Jet
2
Product Code
FQJ
Support, Scrotal, Therapeutic
1
Product Code
FQK
Binder, Perineal
1
Product Code
FQL
Stocking, Medical Support (For General Medical Purposes)
1
Product Code
FQM
Bandage, Elastic
1
Product Code
FRF
Cleaner, Air, Medical Recirculating
2
Product Code
FRL
Fiber, Medical, Absorbent
1
Product Code
FRN
Pump, Infusion
2
Product Code
FRP
Holder, Infant Position
1
Product Code
FRR
Chamber, Reverse Isolation, Patient Care
2
Product Code
FSA
Lift, Patient, Non-Ac-Powered
1
Product Code
FSD
Binder, Abdominal
1
Product Code
HEF
Binder, Breast
1
Product Code
HFS
Shield, Nipple
1
Product Code
IKY
Mattress, Flotation Therapy, Non-Powered
1
Product Code
KMK
Device, Intravascular Catheter Securement
1
Product Code
KMO
Binder, Elastic
1
Product Code
KPE
Container, I.V.
2
Product Code
KYP
Snake Bite Suction Kit
1
Product Code
KYQ
Kit, Chemical Snake-Bite
3
Product Code
KZD
Infusor, Pressure, For I.V. Bags
1
Product Code
KZE
Injector, Fluid, Non-Electrically Powered
2
Product Code
LBI
Unit, Neonatal Phototherapy
2
Product Code
LDR
Controller, Infusion, Intravascular, Electronic
2
Product Code
LGM
Chamber, Patient Isolation
2
Product Code
LGN
Chamber, Patient Transport Isolation
2
Product Code
LGZ
Warmer, Thermal, Infusion Fluid
2
Product Code
LHF
Warmer, Microwave, Infusion Fluid
2
Product Code
LHI
Set, I.V. Fluid Transfer
2
Product Code
LJL
Detectors And Removers, Lice, (Including Combs)
1
Product Code
LJS
Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
2
Product Code
LJT
Port & Catheter, Implanted, Subcutaneous, Intravascular
2
Product Code
LLI
Bed, Therapeutic, Ac-Powered, Adjustable Home-Use
2
Product Code
LLK
Legging, Compression, Non-Inflatable
2
Product Code
LZH
Pump, Infusion, Enteral
2
Product Code
MDR
Binder, Medical, Therapeutic
1
Product Code
MEA
Pump, Infusion, Pca
2
Product Code
MEB
Pump, Infusion, Elastomeric
2
Product Code
MEG
Syringe, Antistick
2
Product Code
MHC
Needle, Interosseous
2
Product Code
MHD
Pump, Infusion, Gallstone Dissolution
2
Product Code
MJF
Check Valve, Retrograde Flow (In-Line)
2
Product Code
MMK
Container, Sharps
2
Product Code
MQX
Needle, Acupuncture, Single Use
2
Product Code
MRZ
Accessories, Pump, Infusion
2
Product Code
MZR
Topical Approximation System
1
Product Code
NEP
System/Device, Pharmacy Compounding
2
Product Code
NGT
Saline, Vascular Access Flush
2
Product Code
NKK
Needle, Hypodermic, Single Lumen, Reprocessed
2
Product Code
NKN
Syringe, Piston, Reprocessed
2
Product Code
NRW
Stimulator, Intramuscular, Automatic
2
Product Code
NSC
Injector, Pen
2
Product Code
NTC
Nursing Pad, Hydrogel
1
Product Code
NTX
Nursing Pad, Polyurethane Pad With Starch Copolymer, Glycerin, And Surfactant (F-68)
1
Product Code
NXH
Nursing Pad, Cohesive Gel
1
Product Code
NZG
Bassinet, Hospital
2
Product Code
NZW
Heparin, Vascular Access Flush
2
Product Code
NZX
Water, Vascular Access Flush
2
Product Code
OBK
Port, Protector/Cushion
2
Product Code
ODI
Administration Set Docking Station
2
Product Code
ODY
Tunneled Catheter Remover
2
Product Code
OJA
Intravenous Extension Tubing Set
2
Product Code
OKC
Implanted Subcutaneous Securement Catheter
2
Product Code
OKE
Port Introducer Kit
2
Product Code
OKL
Intravascular Administration Set, Automated Air Removal System
2
Product Code
OMF
Percutaneous, Implanted, Long-Term Intravascular Catheter Accessory For Catheter Position
2
Product Code
ONB
Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System
2
Product Code
ONM
Radiant Infant Warmer Cabinet
2
Product Code
PUK
Administration Set Securement Device
1
Product Code
OPP
Pump, Infusion, Insulin Bolus
2
Product Code
OSI
Bariatric Bed
2
Product Code
OUW
Infant Positioner, Rx, Use In Highly Monitored Setting
1
Product Code
OWL
Peripheral Catheter Insertion Kit
2
Product Code
PDH
Blanket, Neonatal Phototherapy
2
Product Code
PEF
Heparin Flush In 0.45% Sodium Chloride
2
Product Code
PEZ
Central Venous Catheter Dressing Change Kit
2
Product Code
PHC
Infusion Safety Management Software
2
Product Code
PKP
Immunoglobulin G (Igg) Infusion System
2
Product Code
PMS
Peripheral Intravenous (Piv) Infiltration Monitor
2
Product Code
PND
Midline Catheter
2
Product Code
POQ
Blood Transfusion Kit
2
Product Code
POR
Parenteral Administration Kit
2
Product Code
PQH
Iodinated Contrast Media Transfer Tubing Set
2
Product Code
PQX
Epinephrine Syringe
2
Product Code
PRN
Pediatric Position Holder
1
Product Code
PTD
Subcutaneous Implanted Apheresis Port
2
Product Code
PTI
Non-Coring (Huber) Needle
2
Product Code
PUN
Lice Removal Kit Containing A Solution
1
Product Code
PUR
Vacuum Syringe
2
Product Code
PVZ
Non-Stainless Steel Needle
2
Product Code
PWH
Administrations Sets With Neuraxial Connectors
2
Product Code
PWN
Baby Care Kit
2
Product Code
PWO
Blood Administration Kit
2
Product Code
PWQ
Buret Administration Intravenous Kit
2
Product Code
PWR
Catheter Repair Kit
2
Product Code
PWX
Insect Sting Emergency Kit
1
Product Code
PWY
Lumbar Puncture Tray (Adult & Pediatric)
2
Product Code
PXB
Percutaneous Introducer Kit
2
Product Code
PXI
Thoracentesis Tray
2
Product Code
PXJ
Umbilical Catheter Insertion Tray
2
Product Code
PXK
Vascular Access Port Kit
2
Product Code
PXL
Venipuncture Kit
2
Product Code
PYR
Neuraxial Administration Set - Intrathecal Delivery
2
Product Code
PZW
Catheter Access Cover, Tamper-Resistant
2
Product Code
QBL
Piston Syringe Lever
2
Product Code
QDM
Midazolam Syringe
2
Product Code
QEH
Piston Syringe With Neuraxial Connector – Epidural, Peripheral, And/Or Indirect Cerebral Spinal Fluid Contact
2
Product Code
QJY
Infusion Pump, Drug Specific, Pharmacy-Filled
2
Product Code
QLF
On-Body Injector
2
Product Code
QLY
Ophthalmic Syringe
2
Product Code
QMT
Prep Kit – Vaccine Injection
2
Product Code
QNQ
Low Dead Space Piston Syringe
2
Product Code
QNS
Low Dead Space Needle, Single Lumen, Hypodermic
2
Product Code
QOG
Injection Data Capture Device
2
Product Code
QOI
Intravenous Catheter Force-Activated Separation Device.
2
Product Code
QTI
Saline Vascular Access Flush With Integrated Alcohol Disinfectant Device
2
Product Code
QYM
Ophthalmic Needle
2
Product Code
SCL
Allergen And Vaccine Delivery Needles
2
Product Code
SEF
Central Venous Catheter With Manual Insertion System
2
Product Code
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Subpart G—General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
Subpart G—Miscellaneous Devices
CFR Sub-Part
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
HO
/
subpart-f—general-hospital-and-personal-use-therapeutic-devices
/
FOZ
/
K944367
View Source
CATCO POLYURETHANE UMBILICAL VESSEL CATHETER
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K944367
510(k) Type
Traditional
Applicant
CATCO MEDICAL, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
4/5/1995
Days to Decision
210 days
Submission Type
Statement
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
Subpart B—Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart C—General Hospital and Personal Use Monitoring Devices
Subpart D—Pathology Instrumentation and Accessories
Subpart D—Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—General Hospital and Personal Use Therapeutic Devices
BRZ
Set, Blood Transfusion
BWJ
Locator, Acupuncture Point
CAK
Microfilter, Blood Transfusion
DWL
Stocking, Medical Support (To Prevent Pooling Of Blood In Legs)
FMF
Syringe, Piston
FMG
Stopcock, I.V. Set
FMI
Needle, Hypodermic, Single Lumen
FMS
Bed, Pediatric Open Hospital
FMT
Warmer, Infant Radiant
FMZ
Incubator, Neonatal
FNG
Lift, Patient, Ac-Powered
FNJ
Bed, Manual
FNK
Bed, Hydraulic, Adjustable Hospital
FNL
Bed, Ac-Powered Adjustable Hospital
FNM
Mattress, Air Flotation, Alternating Pressure
FNN
Nipple, Lambs Feeding
FOD
Device, Occlusion, Umbilical
FOH
Mattress, Water, Temperature Regulated
FOK
Pad, Neonatal Eye
FOS
Catheter, Umbilical Artery
FOZ
Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
K
25
2398
SURFLO Hybria Closed System Safety IV Catheter
K
25
2677
Polyshield Safety IV Catheters
K
25
1422
BD Saf-T-Intima™ Subcutaneous Catheter System
K
24
3403
BD Nexiva™ Closed IV Catheter System
K
25
1155
BD Cathena™ Safety IV Catheter
K
25
1654
BD Insyte™ Autoguard™ Shielded IV Catheter, BD Insyte™ Autoguard™ BC Shielded IV Catheter and BD Insyte™ Autoguard™ BC Pro Shielded IV Catheter
K
25
0682
BD Nexiva™ Diffusics™ Closed IV Catheter System and BD Nexiva™ Diffusics™ Closed IV Catheter System with BD MaxZero™ Needle-free Connector
K
24
3105
Ruby Intravascular Catheter
K
25
0292
OSPREY Midline Closed IV Catheter System (OspreyEDC-F20)
K
24
4059
HydroMID 5F Dual Lumen Midline Catheter - Basic Kit (70006102); HydroMID 5F Dual Lumen Midline Catheter - Max Barrier Kit (70006104); HydroMID 5F Dual Lumen Midline Catheter - Mobile Max Barrier Kit (90006104)
K
24
3599
Arrow™ Endurance™ Extended Dwell Peripheral Catheter System (EDC-00818)
K
24
2281
Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00620); Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00622); Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00820); Arrow Endurance Extended Dwell Peripheral Catheter System (EDC-00822)
K
24
1115
SV Spectrum MRC Central Venous Catheter; SV Spectrum MR Central Venous Catheter; SV Central Venous Catheter
K
24
0359
PowerGlide Pro™ Midline Catheter
K
24
1845
Introcan Safety® 2 IV Catheter
K
23
3106
AccuCath Ace™ Intravascular Catheter
K
23
2234
Nouvo Safety Set
K
23
3529
BD Nexiva™ Diffusics™ Closed IV Catheter System with BD MaxZero™ Needle-free Connector
K
23
1239
Nexiva™ Closed IV Catheter System with NearPort™ IV Access
K
23
1401
Polysafety BC, Polysafety BC Adva, Polywin Safety, Polywin Safety Adva
K
22
3788
The MedSource TrueSafe Blood Control I.V. Safety Catheter, and the MedSource ClearSafe Blood Control I.V. Safety Catheter
K
23
1626
OSPREY Closed IV Catheter System (OspreyV2)
K
22
1827
Mais Central Venous Catheter
K
23
0616
Polyguard and Polyshield Safety IV Catheters
K
22
3018
OSPREY PERIPHERAL IV Catheter System
K
22
3648
Cook® Spectrum® 2 MRC Central Venous Catheter
K
22
0772
HydroMID 4F Single Lumen Midline Catheter
K
21
0929
MagiCath II
K
21
2370
Leaderflex Mini and Leaderflex Nano
K
22
0756
Introcan Safety 2 IV Catheter
K
22
0626
Introcan Safety IV Catheter
K
22
0584
BD Cathena Safety IV Catheter
K
21
0037
Pluski Safe 1 Safety IV Catheter
K
21
3664
B. Braun Introcan Safety 2 IV Catheter
K
21
3085
Introcan Safety 3 Closed IV Catheter
K
20
2060
Disposable IV catheter
K
20
0891
BD Intima II Closed IV Catheter System, BD Intima II PLUS Closed IV Catheter System
K
20
3069
HydroMID
K
20
1075
BD Insyte Autoguard Shielded IV Catheter, BD Insyte Autoguard BC Shielded IV Catheter, BD Insyte Autoguard BC Pro Shielded IV Catheter
K
19
3158
ACENT™ Central Venous Catheter
K
20
1717
BD Cathena Safety IV Catheter
K
20
0373
Deltaven Fast Flash Closed I.V. Catheter Systems
K
19
3278
MedSource CathMED IV Catheter
K
19
2230
MF SAFECATH
K
20
0266
BD Centro Vena Acute Central Line (7 French Dual Lumen)
K
19
2676
Introcan Safety 2 IV Catheter 18-24 gauge
K
20
0263
Health Line CT Midline Catheter
K
19
2493
BD Cathena (TM) Safety IV Catheter
K
19
2533
Health Line CT CVC
K
19
0855
BD Acute Central Line
K
19
0001
Supercath 5
K
19
1232
AccuCath Ace Intravascular Catheter
K
18
2252
Cook Unimpregnated Central Venous Catheter
K
18
3399
BD Nexiva Closed IV Catheter System
K
18
2870
Introcan Safety 3 Closed IV Catheter
K
18
2538
Merit RadialFlo Arterial Catheter
K
17
2496
SUPERCATH 5 (26G)
K
17
1530
Deltaven XiV Max, Deltaven XiV Max FF
K
17
3354
BD Nexiva Diffusics Closed IV Catheter Systems
K
17
2506
BD Cathena Safety IV Catheter
K
17
2204
BD Intima II PLUS Closed IV Catheter System
K
16
3358
Introcan Safety 3 Closed IV Catheter
K
17
0336
BD Nexiva Closed IV Catheter System (Single Port) with MaxZero Needleless Connector
K
16
1681
Nipro SafeTouch IV Catheter
K
17
0283
BD Nexiva Diffusics Closed IV Catheter System
K
16
3513
Arrow Endurance Extended Dwell Peripheral Catheter System
K
16
2894
AccuCath Intravascular Catheter
K
16
1779
MedSource TrueSafe Safety IV Catheter, MedSource TrueSafe Comfort Safety IV Catheter
K
16
2377
PowerGlide Pro Midline Catheter
K
16
1866
BioFlo Midline Catheter
K
16
1777
BD Nexiva and BD Nexiva Diffusics Closed IV Catheter Systems
K
16
0592
SUPERCATH 6
K
16
0235
ViaValve Safety I.V. Catheter
K
15
3280
PowerGlide Pro Midline Catheter
K
16
0374
20G x 1.25 NovaCath Secure IV Catheter System, 24G x 0.56 NovaCath Secure IV Catheter System
K
15
3298
AccuCath Intravascular Catheter
K
15
2272
Arrow Endurance Extended Dwell Peripheral Catheter System
K
15
1698
BD Angiocath IV Catheter, BD Insyte IV Catheter
K
15
0611
MedSource ClearSafe Safety IV Catheter
K
15
1513
Arrow Endurance Extended Dwell Peripheral Catheter System
K
14
2797
I.V. Catheter
K
15
0109
Arrow Pressure Injectable Jugular Axillo-subclavian Central Catheter (JACC) with Sustain Technology
K
15
0407
BioFlo Midline Catheter
K
14
3610
BD INTIMA II CLOSED IV CATHETER
K
14
2136
ACCUCATH MIDLINE CATHETER SYSTEM
K
14
0270
NEXUS MIDLINE CT CATHETER
K
14
1026
LEADERFLEX
K
14
0504
ACCUCATH BC INTRAVASCULAR CATHETER SYSTEM
K
13
3280
TERUMO SURFLO I.V. CATHETER
K
14
1138
SURFLASH SAFETY I.V. CATHETER
K
14
0419
SUPERCATH5
K
14
0136
NIPRO SAFETOUCH PSV SCALP VEIN SET WITH SAFETY DEVICE
K
13
1555
MEDSOURCE IV SAFETY CATHETER
K
13
3856
POWERGLIDE MIDLINE CATHETER
K
13
2153
SAFETOUCH PSV WINGED INFUSION SET WITH/WITHOUT FILTER
K
13
0518
MINI-MIDLINE EXTENDED DWELL SAFETY CATHETER
K
12
1488
JMS SAFE WING CATH (SWC)
K
12
3734
BD NEXIVA DIFFUSICS CLOSED IV CATHETER SYSTEM
K
12
1007
NEO DELTA SELF SAFE T, NEO DELTA SELF SAFE T, NEO DELTA SELF SAFE 1, NEO DELTA SELF SAFE 1
K
12
3267
SURFFLASH(R) PLUS SAFETY I.V. CATHETER
K
12
2544
TERUMO SURFLASH SAFETY I.V. CATHETER
K
12
0839
NOVACATH SECURE IV CATHETER SYSTEM-18G
K
11
1939
M/29TM - PRESSURE INJECTABLE
K
12
1073
POWERGLIDE MIDLINE CATHETER
K
11
3622
ORION II CT CVC
K
11
3565
MULTI-MED CENTRAL VENOUS CATHETERS (CVCS), WITH AND WITHOUT HEPARIN VANTEX CENTRAL VENOUS CATHETERS (CVCS), WITH HEPARIN
K
11
2290
SUPERCATH Z3V
K
11
3700
VIAVALVE SAFETY IV CATHETER
K
11
3429
SAFETOUCH PSV WINGED INFUSION SET, AND SET WITH FILTER
K
12
0337
I-PORT ADVANCE INJECTION PORT
K
11
2542
YOMURA SAFETY I.V. CATHETER
K
11
0794
AMECATH CVC AND AMECATH PRESSURE CVC SHORT TERM SINGLE AND MULTI-LUMEN CATHERIZATION KITS
K
11
1366
BD NEXIVA DIFFUSICS CLOSED IV CATHETER SYSTEM
K
11
2347
RAPID INTRAVASCULAR CATHETER START SYSTEM 22 GAUGE / 20 GAUGE / 18 GAUGE
K
11
1236
INTROCAN SAFETY (R) 3 CLOSED IV CATHETER 18GA X 1-3/4 (45MM) AND 18GA X 1-1/4 (32MM) / 20GA X 1-1/4 (32MM) / 20GA X 1
K
11
0443
BD INSYTE AUTOGUARD BC
K
10
2520
BD NEXIVA CLOSED IV CATHETER SYSTEM
K
10
0775
BD INTIMA II CLOSED IV CATHETER
K
10
0974
SPECTRUM TURBO-JECT PICC SET
K
10
0282
TERUMO SURSHIELD- PUR SAFETY I.V. CATHETER
K
09
3546
SUPERCATH 5 MODEL SP120-XX-XX, SP125-XX-XX
K
09
1709
MULTI-MED CENTRAL VENOUS CATHETERS, MODELS: M3720HKIC, M4820HKIC
K
09
2629
SNM FIRMGRIP
K
08
3429
I.V. CATHETER, MODELS: TYPE I, TYPE Y, TYPE STRAIGHT
K
09
0973
TERUMO SURSHIELD SAFETY I.V. CATHETER (18G X 51MM & 20G X 51MM SIZES)
K
08
2997
TERUMO HYBRIA CLOSED SYSTEM SAFETY I.V. CATHETER
K
08
1953
SUPERCATH 5
K
09
0502
NOVA SAFE SCALP VEIN BLOOD COLLECTION SET
K
09
0122
NUOVOGUARD
K
08
3454
NUOVOCATH
K
08
1420
VANISHPOINT I.V. CATHETER
K
08
0793
FIRMGRIP
K
08
2362
SURSHIELD SAFETY I.V. CATHETER
K
08
1113
COOK AND COOK SPECTRUM CENTRAL VENOUS CATHETERS
K
08
1690
SPECTRUM TURBO-JECT PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER
K
07
3471
VANTAGECATH INTRAVASCULAR CATHETER
K
07
3520
ANGIOTECH CVC
K
07
3241
VASCULAR PATHWAYS RIVS RAPID INTRAVASCULAR CATHETER START SYSTEM
K
07
0705
MODIFICATION TO: LATEX-FREE BIONECTOR, MODEL# 896.019, 896.039
K
07
2419
ADVANTIV SAFETY I.V. CATHETER
K
07
1382
SCM CATH ( SIZES ARE VARYING BETWEEN 16G X 2'' AND 24G X 3/4'' ), MODEL 1.50, 1.77,1.88',2, 1.25, 1.50, 1.77,
K
07
1538
ARROW, ARROWG+ARD AND ARROWG+ARD BLUE PLUS PRESSURE INJECTABLE CENTRAL VENOUS CATHETER
K
07
0020
COMCASET-P SAFETY IV CATHETER
K
07
0451
ABLE CENTRAL VENOUS CATHETER
K
06
3469
MEDICAN ALPHA
K
06
1250
MULTICATH EXPERT
K
06
2108
COMCASET SAFETY IV CATHETER
K
06
0341
SHERLOCK TIP LOCATION SYSTEM (TLS)
K
05
2564
VYGON LEADER-FLEX
K
05
2881
VYGON LATEX FREE BIONECTOR
K
06
0174
SPECTRUM FIVE LUMEN CENTRAL VENOUS CATHETER SET, MODEL C-UQLM10.0-ABRM
K
04
2504
CATHY STERILE DISPOSABLE I.V. CANNULA WITH CATHETER
K
05
3120
STERILE FIELD SALINE AND HEPARIN LOCK FLUSH SYRINGES
K
05
1355
VANISHPOINT I.V. CATHETER
K
05
2389
I-PORT
K
05
0114
SUPERCATH Z3V
K
04
3446
EMMEBI CENTRAL VENOUS CATHETER KIT WITH LESTEP SAFETY INTRODUCER
K
04
2862
BD ONECATH
K
03
3843
SPECTRUM CENTRAL VENOUS CATHETER WITH OR WITHOUT HYDROPHILIC COATING
K
04
1345
PROTECTIV JELCO SAFETY I.V. CATHETER, MODEL 3600 SERIES
K
04
0427
FIBREX CATHETER PATENCY DEVICE
K
03
2292
BIOTEQUE A.V. FISTULA NEEDLE SET WITH SAFETY FLEX
K
03
2843
NEXIVA CLOSED IV CATHETER SYSTEM
K
03
2274
COOK FIVE LUMEN CENTRAL VENOUS CATHETER
K
03
3500
BD CAREFLOW CENTRAL VENOUS CATHETER
K
03
3853
MODIFICATION TO V-CATH POLY PICC
K
03
3250
EDWARDS LIFESCIENCES VANTEX CENTRAL VENOUS CATHETERS WITH THERMISTOR
K
03
2417
HEPARIN LOCK FLUSH SYRINGE
K
03
2777
MODIFICATION TO: NIPRO SAFE TOUCH SAFETY FISTULA NEEDLE
K
03
2962
AC 3 LUMEN CENTRAL VENOUS ACCESS KIT WITH ARROWG+ARD ANTIMICROBIAL SURFACE
K
03
0479
JMS SYSLOC A.V. FISTULA NEEDLE SET, JMS SYSLOC APHERESIS NEEDLE SET
K
02
4007
SUNDER CENTRAL VENOUS CATHETER KIT, MODELS SD-3L55F30J AND SD-3L70F30J
K
02
1557
SPECTRUM SILICONE CATHETER
K
02
3253
PEDIATRIC CENTRAL VENOUS CATHETER KIT
K
03
0571
ACUVANCE PLUS SAFETY IV CATHETER, PROTECTIV PLUS SAFETY IV CATHETER, OPTIVA IV CATHETER
K
02
1130
SPECATH CENTRAL VENOUS CATHETER KITS
K
02
2756
NIPRO BIO-FLEX CATHETER
K
02
2099
SAFE-T-PEEL SAFETY NEEDLE/INTRODUCER, MODELS 350-300 S, 360-300'S,380-300'S,390-300'S
K
02
0785
INTROCAN SAFETY IV CATHETER
K
01
3182
TRIPLE LUMEN CENTRAL VENOUS CATHETER
K
02
1139
TRULINE REINFORCED VALVED INFUSION CATHETER
K
00
2142
SALINE IV FLUSH SYRINGE
K
01
1967
BD PRE-FILLED HEPARIN LOCK FLUSH IN 0.9% SODIUM CHLORIDE INJECTION, USP SYRINGE
K
01
3556
MONOJECT PREFILL HEPARIN LOCK FLUSH SYRINGE
K
01
3800
INSYTE, ANGIOCATH, INSYTE AUTOGUARD, ANGIOCATH AUTOGUARD, AUTOGUARD PRO, INTIMA, AND SAF-T-INTIMA INTRAVASCULAR CATHETE
K
01
3287
NIPRO SAFELET CATH
K
01
3073
INSYTE, ANGIOCATH, INSYTE AUTOGUARD, ANGIOCATH AUTOGUARD, AUTOGUARD PRO, INTIMA AND SAF-T-INTIMA INTRAVASCULAR CATHETERS
K
01
1937
TRULINE INFUSION CATHETERS
K
01
2128
PROTECTIV ACUVANCE IV CATHETER SYSTEM
K
01
1982
0.9% SODIUM CHLORIDE INJECTION, USP BD PRE-FILLED FLUSH SYRINGE
K
01
1860
KEYST0NE MEDICAL PICC CATHETER
K
01
1297
NIPRO SAFETOUCH SCALP VEIN AND BLOOD COLLECTION SET
K
01
0410
JMS APHERESIS NEEDLE WING EATER, MODEL 14G-18G
K
01
0406
JMS A.V. FISTULA NEEDLE SET WING EATER, MODEL 14G-18G
K
00
3187
VACUCATH I.V. CATHETER INTRODUCTER
K
00
3553
0.9% SODIUM CHLORIDE INJECTION, USP BD PRE-FILLED FLUSH SYRINGE
K
01
0021
MEDCOMP QUAD LUMEN, 8.5F X 20CM, MODEL MC4L-8S
K
01
0034
DOUBLE LUMEN URETHANE PICC LINE, MODEL UPICDS-
K
00
3245
HEPARIN LOCK FLUSH SYRING 10 USP UNITS/ML, HEPARIN LOCK FLUSH SYRINGE, 100 USP UNITS/ML
K
00
2786
BIOSENSORS CENTRAL VENOUS CATHETER KITS
K
00
1795
THE AVITRO LLC, 10 AND 100 USO UNITS/ML HEPARIN SODIUM VAFD
K
00
0632
0.9% SODIUM CHLORIDE VASCULAT ACCESS DEVICE
K
00
0997
ZORTRAN DETECTOR
K
00
1616
MODIFICATION TO SYRINGE PREFILLED WITH 0.9% SODIUM CHLORIDE
K
00
2033
BD INSYTE AUTOGUARD -P AND BD INSYTE AUTOGUARD -P WINGED IV CATHETERS
K
99
2532
VANTEX CENTRAL VENOUS CATHETER WITH OLIGON MATERIAL WITH OR WITHOUT AMC THROMBOSHIELD COATING
K
99
3518
MEDEFIL'S HEPARIN I.V. FLUSH SYRINGE, IN VARIOUS FILL SIZES - 1 ML FILL IN 3 ML SYRINGE LL; 1 ML FILL IN 6 ML SYRINGE LL
K
00
0665
TFX MEDICAL SAFETY NEEDLE WITH INTRODUCER
K
99
2732
STERILE WATER & STERILE 0.9% SODIUM CHLORIDE
K
00
0235
INSYTE CATHETER, INSYTE AUTOGUARD CATHETER
K
00
0087
MARHUKAR TRIPLE LUMEN CATHETER, MODEL 12 FR
K
99
3691
ARROWG +ARD BLUE PLUS ANTIMICROBIAL MULTI-LUMEN CENTRAL VENOUS CATHETER
K
98
2558
BD PREEFILE NORMAL SALINE FLUSH SYRINGE FLUSH SYRINGE
K
99
3515
MEDEFIL'S NORMAL SALINE FLUSH SYRINGE, IN VARIOUS FILL SIZES - 1 ML FILL IN 3 ML SYRINGE LL; 1 ML FILL IN 6 ML SYRINGE L
K
99
0390
HEPARIN IV FLUSH SYRINGE, 10 U/ML \
K
99
0308
ROCAP HEPARIN IV FLUSH SYRINGE, 100U/ML
K
98
4590
0.9% SODIUM CHLORIDE FLUSH SYRINGE
K
99
2198
URETHANE PICC LINE MODEL UPICS-
K
99
0236
MODIFICATION OF JELCO*,JELCO*-W AND JELCO* PLUS I.V. CATHETERS, CATHLON* I.V. CATHETERS, OPTIVA* I.V. CATHETERS, PROTECT
K
99
1406
TERUMO SURFLO FLEX I.V. CATHETER AND TERUMO SURFLASH I.V. CATHETER
K
98
4614
NORMAL SALINE FLUSH SYRINGE
K
98
4189
ARGON MULTI-LUMEN CENTRAL VENOUS CATHETER
K
98
4059
ANGIOCATH AUTOGUARD CATHETER, INSYTE AUTOGUARD CATHETER
K
98
4055
CLINICATH POLYFLOW POLYURETHANE PERIPHERALLY INSERTED CATHETERS
K
98
2805
INTROCAN SAFETY IV CATHETER
K
97
0736
BRAUN PREFILLED SYRINGE
K
98
3916
V-CATH PICC (PERIPHERALLY INSERTED CENTRAL CATHETER)
K
98
3409
V-CATH PICC (PERIPHERALLY INSERTED CENTRAL CATHETER) SEE APPENDIX 1
K
98
0566
VAXESS PERIPHERALLY INSERTED CENTRAL CATHETER
K
98
1905
STERILE SALINE SOLUTION 0.9%- CATALOG NO, 10290, STERILE WATER- CATALOG NO. 10291
K
97
4015
ARGYLE QUICK- PICC PERIPHERALLY INSERTED CENTRAL CATHETER- PICC TRAYS, ARGYLE QUICK- PICC PERIPHERALLY INSERTED CENTRAL
K
97
3561
MEDCOMP TRI-FLOW SOFT TIP TRIPLE LUMEN CATHETER 11.5F X 12CM, MEDCOMP TRI-FLOW SOFT TIP TRIPLE LUMEN CATHETER 11.5F X 1M
K
98
1382
PASV DUAL LUMEN PERIPHERALLY INSERTED MIDLINE CATHETER MODEL NUMBER MIDLINE-NUMEROUS
K
98
1368
PASV DUAL LUMEN PERIPHERALLY INSERTED CENTRAL CATHETER (PICC) MODEL NUMBER PIC-NUMEROUS
K
98
0493
I.V. CATHETER SYSTEM
K
97
4764
INTROSYTE CATHETER
K
97
4543
L-CATH MODIFIED SELDINGER TECHNIQUE INSERTION/CATHETER EXCHANGE KIT PE-MST24-24 GA. KIT, L-CATH MODIFIED SELDINGER
K
97
1339
INSYTE, INSYTE-W, INSYTE AUTOGUARD CATHETERS
K
97
1990
GESCO PER-Q-CATH PICC CATHETERS
K
97
1991
GESCO PER-Q-CATH MIDLINE CATHETERS
K
97
0864
ARROW-HOWES LARGE BORE MULTI-LUMEN CENTRAL VENOUS CATHETERS
K
97
2262
FIRST PICC CATHETER
K
97
2264
FIRST MIDCATH CATHETER
K
97
2263
FIRST PICC CATHETER WITH DUAL LUMENS
K
97
2254
FIRST MIDCATH CATHETER
K
96
3196
VYGON UMBILICAL CATHETHER INSERTION TRAY
K
96
2577
ARROWGARD BLUE QUAD-LUMEN CENTRAL VENOUS CATHETER
K
97
0669
AEROQUIP SAFESTART IV CATHETER
K
97
0644
AEROQUIP SAFESTART (TM) IV CATH (TM) SYSTEM
K
96
0764
SAFE-CATH
K
96
4966
V-CATH
K
96
1552
CVP POLYURETHANE CATHETER
K
96
4049
FIRST MIDCATH CATHETER WITH DUAL LUMENS
K
96
4048
FIRST MIDCATH CATHETER KIT
K
96
4050
FIRST MIDCATH CATHETER
K
96
2226
PROTECTIV 2000 I.V. CATHETER SAFETY SYSTEM
K
95
3252
DISPOSABLE SCALP VEIN INFUSION SET
K
96
3867
NEO-CARE CATHETERIZATION TRAY
K
96
2938
EXCELSIOR DISPOSABLE SYRINGE W/NORMAL SALINE (.9% SODIUM CHLORIDE)
K
95
3811
MEDCOMP P-CATH
K
95
3805
0.9% SODIUM CHLORIDE DILUENT IN PLASTIC SYRINGE
K
95
4112
VYGON LIFEVAC MID-LINE TRAY
K
95
1620
MIDMARK MIDLINE CATHETER
K
96
0051
NIPRO SAFELET CATH
K
95
4428
SOLOPICC 24 (60CM) 20GA CATHETER
K
95
5839
MULTI-MED MULTI-LUMEN CENTRAL VENOUS CATHETER
K
96
0013
MDC SAFE STEP SAFETY I.V. CATHETER SYSTEM
K
95
0118
ABRM CATHETER
K
95
4887
STERILE WATER O.9% STERILE SALINE
K
95
3335
MICRO THERAPEUTICS VARIABLE INFUSION LENGTH CATHETER
K
95
5053
NIPRO SCALP VEIN SET (DISPOSABL PSV SET)
K
95
3120
VITAL SIGNS HEPARIN VASCULAR ACCESS FLUSH DEVICE
K
95
2645
VITAL SIGNS SALINE VASCULAR ACCESS FLUSH DEVICE
K
94
6170
COMFORT-Q SUBCUTANEOUS INJECTION SETS
K
95
2058
STERILE V.A.D. (VASCULAR ACCESS DEVICES) ACCESS KIT, DISPOSABLE
K
93
2946
WALLACE IV CANNULA
K
93
2947
WALLACE Y-CAN
K
95
2861
ANGIOCATH & INSYTE AUTOGUARD CATHETERS
K
95
2757
ANGIOCATH, NOVBALON, ANGIO-SET INTRAVASCULAR & ANGIOCATH INTRODUCTION DRAINAGE CATHETER
K
95
2256
PICC LINE KIT
K
94
1678
BIONECTOR
K
95
0284
SIMS DELTEC, INC. CATHETER REPLACEMENT CONNECTOR
K
94
5053
LF CT HIG PRESSURE CATHETERS
K
95
0301
ANGIOCATH(R) NONVALON(R) AND ANGIO-SET(R) IV CATHETERS
K
94
4302
THE FLEX-SET SUBCUTANEOUS INFUSION SET
K
94
5521
CENTERMARK(R) PICC INSERTION TRAY LANDMARK(R) MIDLINE CATHETER PREP TRAY
K
94
4410
CATCO SILICONE DUAL LUMEN UMBILICAL VESSEL CATHETER
K
94
4367
CATCO POLYURETHANE UMBILICAL VESSEL CATHETER
K
94
4368
CATCO SILICONE UMBILICAL VESSEL CATHETER
K
94
4336
CATCO UMBILICAL VESSEL CATHETER
K
94
4504
CATCO FIRST PICC
K
95
0737
LANDMARK MIDLINE CATHETER
K
94
4968
LANDMARK MIDLINE CATHETER
K
94
3349
MAHURKAR DUAL LUMEN CATHETER
K
94
4660
ACUTE CENTRAL VENOUS ACCESS CATHETER TRAY
K
94
4511
ACUTE CENTRAL VENOUS ACCESS CATHETER (ACVAC)
K
94
2045
INSYTE INTRODUCER CATHETER
K
93
3467
PRN ADAPTER
K
94
0634
MICRO THERAPEUTICS INFUSION CATHETER
K
93
5090
CUFF-CATH
K
94
1417
VITAFLON PLUS/VASCULON
K
94
3023
CVD BULLETT PERIPHERAL INFUSION CATHETER
K
93
2789
ONE-SITE IV CONNECTOR
K
94
0775
INJECTION CAP
K
94
0441
DIAL MEDICAL SUPPLY FISTULA NEEDLE SET
K
94
0385
NAVIGATOR-MP CATHETER LOCATION INSTRUMENT
K
93
0048
SAFE-PICC CATHETER
K
93
1073
CATH-FINDER
K
92
6544
PHARMACIA DELTEC PERIPHERALLY INSERTED VENOUS CATH
K
93
1668
PICC INSERTION TRAY
K
93
1729
I.V. START KIT
K
93
2071
I.V. START KIT
K
93
1027
BULLETT PERIPHERAL INFUSION CATHETER
K
92
6405
.9% NORMAL SALINE TUBE/STERILE WATER TUBE
K
93
3050
CHANGES TO PROTECTIV(TM) & JELCO(TM) WINGED CATH
K
92
3702
INTIMA POINT GUARD INTRAVASCULAR CATHETER
K
92
6097
CYBILNATE(R) UMBILICAL CATHETER
K
92
3323
INTERMITTENT INJECTION SITE
K
92
4968
L-CATH PEEL-AWAY CATHETER SYSTEM
K
91
4378
PERIPHERAL INTERVENOUS CATHETER
K
92
0638
BIO-MATE PIC CATHETER
K
92
1955
QUIK FLOW
K
91
5824
HOLE PUNCH
K
91
4528
SAFEDWEL(R) CENTRAL VENOUS CATHETER
K
92
1270
SAFE-DWELL PLUS CENTRAL VENOUS CATHETER
K
92
0828
SAFE-PICC PERIPHERALLY INSERTED CENTRAL VENOUS CAT
K
91
4180
DESERET(R) FLOW RESTRICTION VALVE
K
92
0635
E-Z SET/MINICATH INFUSION SETS
K
92
0128
VERSACATH MAINLINE CENTRAL VENOUS CATHETER
K
92
0133
VERSACATH SELECTALUMEN INNER CATHETER
K
92
0028
LANDMARK MIDLINE CATHETER
K
91
5065
I.V.IRRIGATION POLE
K
91
2358
LANDMARK ADD-A-LUMEN CATHETER KIT
K
91
2165
LANDMARK DUAL-LUMEN MIDLINE CATHETER SYSTEM
K
91
1251
FLEX-IV
K
91
2158
CENTRAL VENOUS CATHETER DRESSING CHANGE TRAY
K
91
2563
ANGEL WING SAFETY BLOOD COLLECTION AND INFUSION SE
K
90
5415
BRAIDED HIGH PRESSURE CATHETER CONNECTOR
K
91
0566
VERSACATH(TM) MULTILUMEN SYSTEM
K
91
0565
VERSACATH(TM) SELECTALUMEN(TM) W/CONVERSION TRAY
K
91
0564
VERSACATH(TM0 MAINLINE(TM) WITH INTRODUCTION TRAY
K
91
0572
INJECTION CAPS
K
91
0799
LANDMARK VENOUS ACCESS DEVICE
K
90
4558
DUAL LUMEN 5 FR PERIP CENT VEN CATH W/GROSHONG VAL
K
90
5463
GENERAL MEDICAL PROCEDURE KIT/SKIN PREPARATION
K
90
5009
DIGITCARE I.V. START KIT
K
90
4648
SAFE SYTE I.V. CATHETER PLACEMENT UNIT
K
90
3347
SODIUM CHLORIDE SOLUTION
K
90
4150
CATH-FINDER(TM) CATHETER TRACKING SYSTEM
K
90
3545
CAREKITS(TM), IV/CATH/CENT LINE DRESS/TPN/CVP KITS
K
90
4121
VIALON OBTURATOR
K
89
6813
MODIFIED INTRAVENOUS CATHETER
K
90
4122
INSYTE-A ARTERIAL CATHETERIZATION UNIT
K
90
3732
KENDALL SAFETRAK(TM) HIGH FLOW CATHETER
K
90
1701
CENTRAL VENOUS ACCESS CATHETER
K
90
2527
SPLIT-SECOND INTRODUCER
K
89
5597
VAS-CATH TRIFUSION TRIPLE LUMEN INFUSION CATHETER
K
89
5812
SHARGHP INTRAVENOUS CATHETER
K
90
1263
NAVION SMART-WIRE(TM) CATHETER LOCATION SYSTEM
K
90
0056
CATHETER WITH GUIDEWIRE ASSEMBLY DEVICE
K
90
1640
MULTICATH PLACEMENT KIT
K
90
2135
PERCUTANEOUS INTRODUCER KIT
K
90
0263
ANTIMICROBIAL MULTI-LUMEN CENTRAL VENOUS CATHETER
K
89
5942
GESCO DUAL LUMEN PER-Q-CATH-DL
K
90
0116
DESERET OPTIMA INTRAVASCULAR CATHETER
K
89
5734
DESERET INTRAVASCULAR CATHETER
K
89
5768
EXEL SAFELET CATHETER
K
89
6774
STREAMLINE VASCULAR ACCESS DEVICE
K
89
4611
CATHETER CARE KITS
K
89
5191
ANTI-THROMBOGENIC COATING FOR CATHETERS
K
89
3546
OPTICALLY CLEAR RADIOPAQUE CATHETER
K
89
4371
NIPRO SAFELET CATH
K
89
3965
PROLONG INTRAVASCULAR CATHETER
K
88
4577
PROCEDURE READY TRAYS
K
89
3003
TOCOLYTIC SITE CARE SUP KIT #1001/100A/CARRY CASE
K
89
1087
TERUMO SURFLO(R) I.V. CATHETER
K
88
4325
SUBCLAVIAN HEMODIALYSIS CATH. W/VITACUFF DEVICE
K
89
0751
ACCI-GUARD(TM) I.V. CATHETER PLACEMENT UNIT
K
89
0435
VITAACCESS CATHETER INTRODUCER KIT
K
88
4806
LUMED EXPANDO-CATH, ACTIV
K
88
4701
CATH-FINDER SYSTEM
K
88
3980
LANDMARK VENOUS ACCESS DRIVE (ADDITIONAL SIZES)
K
88
3866
NEOSOFT UMBILICAL VESSEL CATHETER
K
88
4259
MODIFIED LANDMARK VENOUS ACCESS DEVICE
K
88
3415
VASCULON 2 INTRAVENOUS CANNULA
K
88
1767
VIGGO INSUFLON
K
88
1976
CATHETER, INTRAVASCULAR
K
88
2242
LANDMARK(TM) VENOUS ACCESS DEVICE
K
88
1215
CENTRASIL SILICONE ELASTOMER CENTRAL VENOUS CATH
K
88
1236
TORAY ANTHRON P-U CATHETERS
K
88
1666
HR(TM) INTRAVASCULAR CATHETER
K
88
0260
SAFECATH
K
87
2998
VITAACCESS (TM) CATHETER INTRODUCER SYSTEM
K
87
5082
O.P.C. INTRAVASCULAR CATHETER
K
87
5177
J&J SCALP VEIN INFUSION SETS
K
87
4582
DESERET SPLITTABLE CATHETER
K
87
3050
VASCULAR ACCESS CATHETER W/ANTIMICROBIAL CUFF
K
87
2585
CHURCHILL-CATH
K
87
1546
SAFESIDE(TM) LUMED
K
87
0403
CAVAFIX(R) CENTRAL VENOUS CATHETER KIT W/SUTURE
K
86
4949
INSTRUCTION CHANGE FOR RIGHT ATRIAL/RAAF CATHETER
K
86
2153
ARROW 18GA TWO-LUMEN INTRAVENOUS CATH/23GA NEEDLE
K
86
4038
SUPERCATH I.V. CATHETER
K
86
1725
INTRACATH INTRAVENOUS CATHETER PLACEMENT UNIT
K
86
2130
COMFORT-SET* I.V. CATHETER PLACEMENT UNIT.
K
86
2480
BT CATH (INTRAVASCULAR CATHETER)
K
86
1479
CAVAFIX, CENTRAL VENOUS CATHETER KIT
K
86
1117
ANTHRON CATHETERS & SETS
K
86
1510
MULTILUMEN VIAPIC CENTRAL LINE CATHETER
K
86
0474
STREAM LINE* I.V. CATHETER PLACEMENT UNIT
K
85
3988
FORAN CORP-SURESERT INTRAVENOUS CATHETER PLACE UNI
K
86
1015
ONE TIME HYPERAL & CATHETER DRESSING CHANGE TRAYS
K
85
4308
POLYCATH-H CATHETER
K
86
0256
BRAWN AND GROSHONG CATHETERS
K
86
0290
VIAPIC CENTRAL LINE CATHETER
K
85
4566
TERUMO SURFLO ETFE I.V. CATHETER
K
85
3348
L-CATH EXPANDO CATH
K
85
3701
JELCO & CATHLON IV STRIPED IV CATHETERS-RADIOPAGUL
K
85
1142
TELET-LEX MEDICAL IV CATHETER PLACEMENT
K
85
1981
NO. 5300-3 1/2 FRENCH UMBILICAL VESSEL CATH. ETC.
K
85
1327
DESERET ARTERIAL CATHETER
K
85
2078
SPECTRUM(TENTATIVE)
K
84
4193
QUINTON INJECTION SEALING CAP
K
85
0887
DRESSING CHANGE KIT
K
85
1101
BIONOMY'S MULTI-LUMEN CENTRAL VENOUS CATHETER-SET
K
85
0276
VIGGO NEOFLON INFUSION CANNULA
K
85
0460
VIGGO SECALON T CATHETER
K
85
0349
VIGGO ARTERIAL CANNULA
K
85
0278
VASCULON I.V. CANNULAE
K
85
0398
NU-CATH EMERGENCY KIT
K
84
2577
CATH-TECH POLYURETHANE UMBILICAL VESS
K
84
2133
EYRTHROCATH DOUBLE-LUMEN CENTRAL VENOUS
K
85
0369
QUINTON WHITE SEALING CAP
K
84
1880
ERYTHROCATH UMBILICAL CATHETER
K
84
3033
DESERET INTRAVASCULAR CATHETER
K
84
4219
DESERET DENTRAL LINE CATHETER
K
84
4113
DESERET SUBCLAVIAN JUGULAR CATHETER SET
K
84
0815
LUER LOCKING ADAPTER(MATERIAL CHANGE)
K
84
0116
DESERET INFANT CENTRAL VENOUS CATHE-
K
84
0862
DESERET CENTRAL VENOUS CATHETER
K
84
0355
DESERET MULTILUMEN SUBCLAVIAN JUGULAR
K
84
0183
DESERET MULTILUMEN SUBCLAVIAN JUGULAR
K
83
4227
DESERET SUBCLAVIAN JUGULAR CATH. SET
K
83
4255
PBC SCALP VEIN SET
K
83
4073
CENTRAL VEIN CATHERIZATION TRAY CC-20
K
83
4393
DESERET NEONATAL CATHETER SET
K
83
4480
INJECTION CAP
K
83
3079
CENTRACATH #130,135 & 137-HEMOCATH #
K
83
3657
ANGIO-SET INTRAVENOUS CATH. SET
K
83
2558
RELEASE OF ETHYLENE OXIDE-STERILIZ. DEV
K
83
3135
INTRACATH INTRAVENOUS CATHETER UNIT
K
83
3091
DESERET SUBCLAVIAN JUGULAR CATH-SET
K
83
3092
DESERET ANGIO-GUIDE LARGE VEIN CATH.
K
83
2624
TOP VENULA I.V. CATHETER SET
K
83
0541
INJECTION SEALING CAP 13791
K
83
0972
I.V. CATHETER PLACEMENT UNIT POLYURETH
K
83
0765
WINGED CATHETER
K
83
0573
PRE VUE
K
83
0539
INTRAVASCULAR CATHETER SET
K
82
3565
MULTI-LUMEN INTRAVENOUS CATHETER
K
82
3351
CENTRAL VENOUS CATHETER
K
82
2776
TEFLON CANNULA
K
82
3017
INTRAVENOUS CATHETER PLACEMENT UNIT &
K
82
2023
DESERET SUBCLAVIAN JUGULAR CATH. SET
K
82
1929
SUBCLAVIAN
K
82
1679
LEONARD/NORTON HYPERALIMENTATION CATHET.
K
82
1699
DESERET SUBCLAVIAN JUGULAR CATHETER SET
K
82
1577
DESERET ANGIO GUIDE
K
82
1371
DESERET SUBCLAVIAN JUGULAR CATHETER SET
K
82
1372
DESERET INTRACATH INTRAVENOUS CATHETER
K
81
3374
NUTRICATH
K
81
3396
VERSCHLUBSTOPFEN COMB-CLOSING STOPPER
K
81
3345
CRITIKON I.V. CATHETER PLACEMENT UNIT
K
81
2137
B-D HEPARINIZED LONGDWEL I.V. CATHETER
K
81
2159
INTRAVASCULAR CATHETER
K
81
1171
VASCULON II I.V. CATHETER
K
80
3238
INTRAVASCULAR CATHETER
K
80
2918
ANTHRON CATHETER SET
K
80
1537
START IT WITH & WITHOUT I.V. CATH. UNIT
K
80
1941
BURRON MICROCATH INTRA. CATH. PLACEMENTT
K
80
1575
L-CATH INTRAVENOUS PLACEMENT UNIT
K
80
1414
ERYTHROCATH INTRAVENOUS CATHETER PLA. U.
K
80
0786
INJECTION SITE, CODE NO. 3100
K
80
0525
MEDICAL COMPONENTS IV CATHETER
K
79
1918
JELCO WINGED INTRAVASCULAR CATHETER
K
79
0914
SILASTIC INTRAVENOUS CATHETER UNIT
K
79
0967
CATHETER METAL HUB/RADIOPAQUE
K
77
2011
WHOLEY OCCLUSION BALLOON CATHETER
K
79
0968
CATHETER METAL HUB/NONRADIOPAQUE
K
78
0350
I.V. START KIT
K
78
0105
NEEDLE CONNECTING SET, BLUNT
K
77
2354
I.V. CATHETER
K
77
1381
IV CATHETER HUB
K
77
1573
DUO-CATH FEMORAL
K
77
0751
CATHETERS, OVER-THE-NEEDLE
K
77
0510
CANNULA, INTRAVENOUS, TEFLON
K
77
0511
CANNULA, INTRAVENOUS, HEPARINIZED
K
77
0181
I.V. CATHETER PLACEMENT UNIT
K
77
0403
CATHETER-THRU-NEEDLE DEVICE
K
76
0319
KIT, CATHETER
K
76
0163
CATHETER, INTRAVASCULAR (MEDICUT T)
FPA
Set, Administration, Intravascular
FPB
Filter, Infusion Line
FPK
Tubing, Fluid Delivery
FPL
Incubator, Neonatal Transport
FQH
Lavage, Jet
FQJ
Support, Scrotal, Therapeutic
FQK
Binder, Perineal
FQL
Stocking, Medical Support (For General Medical Purposes)
FQM
Bandage, Elastic
FRF
Cleaner, Air, Medical Recirculating
FRL
Fiber, Medical, Absorbent
FRN
Pump, Infusion
FRP
Holder, Infant Position
FRR
Chamber, Reverse Isolation, Patient Care
FSA
Lift, Patient, Non-Ac-Powered
FSD
Binder, Abdominal
HEF
Binder, Breast
HFS
Shield, Nipple
IKY
Mattress, Flotation Therapy, Non-Powered
KMK
Device, Intravascular Catheter Securement
KMO
Binder, Elastic
KPE
Container, I.V.
KYP
Snake Bite Suction Kit
KYQ
Kit, Chemical Snake-Bite
KZD
Infusor, Pressure, For I.V. Bags
KZE
Injector, Fluid, Non-Electrically Powered
LBI
Unit, Neonatal Phototherapy
LDR
Controller, Infusion, Intravascular, Electronic
LGM
Chamber, Patient Isolation
LGN
Chamber, Patient Transport Isolation
LGZ
Warmer, Thermal, Infusion Fluid
LHF
Warmer, Microwave, Infusion Fluid
LHI
Set, I.V. Fluid Transfer
LJL
Detectors And Removers, Lice, (Including Combs)
LJS
Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days
LJT
Port & Catheter, Implanted, Subcutaneous, Intravascular
LLI
Bed, Therapeutic, Ac-Powered, Adjustable Home-Use
LLK
Legging, Compression, Non-Inflatable
LZH
Pump, Infusion, Enteral
MDR
Binder, Medical, Therapeutic
MEA
Pump, Infusion, Pca
MEB
Pump, Infusion, Elastomeric
MEG
Syringe, Antistick
MHC
Needle, Interosseous
MHD
Pump, Infusion, Gallstone Dissolution
MJF
Check Valve, Retrograde Flow (In-Line)
MMK
Container, Sharps
MQX
Needle, Acupuncture, Single Use
MRZ
Accessories, Pump, Infusion
MZR
Topical Approximation System
NEP
System/Device, Pharmacy Compounding
NGT
Saline, Vascular Access Flush
NKK
Needle, Hypodermic, Single Lumen, Reprocessed
NKN
Syringe, Piston, Reprocessed
NRW
Stimulator, Intramuscular, Automatic
NSC
Injector, Pen
NTC
Nursing Pad, Hydrogel
NTX
Nursing Pad, Polyurethane Pad With Starch Copolymer, Glycerin, And Surfactant (F-68)
NXH
Nursing Pad, Cohesive Gel
NZG
Bassinet, Hospital
NZW
Heparin, Vascular Access Flush
NZX
Water, Vascular Access Flush
OBK
Port, Protector/Cushion
ODI
Administration Set Docking Station
ODY
Tunneled Catheter Remover
OJA
Intravenous Extension Tubing Set
OKC
Implanted Subcutaneous Securement Catheter
OKE
Port Introducer Kit
OKL
Intravascular Administration Set, Automated Air Removal System
OMF
Percutaneous, Implanted, Long-Term Intravascular Catheter Accessory For Catheter Position
ONB
Closed Antineoplastic And Hazardous Drug Reconstitution And Transfer System
ONM
Radiant Infant Warmer Cabinet
PUK
Administration Set Securement Device
OPP
Pump, Infusion, Insulin Bolus
OSI
Bariatric Bed
OUW
Infant Positioner, Rx, Use In Highly Monitored Setting
OWL
Peripheral Catheter Insertion Kit
PDH
Blanket, Neonatal Phototherapy
PEF
Heparin Flush In 0.45% Sodium Chloride
PEZ
Central Venous Catheter Dressing Change Kit
PHC
Infusion Safety Management Software
PKP
Immunoglobulin G (Igg) Infusion System
PMS
Peripheral Intravenous (Piv) Infiltration Monitor
PND
Midline Catheter
POQ
Blood Transfusion Kit
POR
Parenteral Administration Kit
PQH
Iodinated Contrast Media Transfer Tubing Set
PQX
Epinephrine Syringe
PRN
Pediatric Position Holder
PTD
Subcutaneous Implanted Apheresis Port
PTI
Non-Coring (Huber) Needle
PUN
Lice Removal Kit Containing A Solution
PUR
Vacuum Syringe
PVZ
Non-Stainless Steel Needle
PWH
Administrations Sets With Neuraxial Connectors
PWN
Baby Care Kit
PWO
Blood Administration Kit
PWQ
Buret Administration Intravenous Kit
PWR
Catheter Repair Kit
PWX
Insect Sting Emergency Kit
PWY
Lumbar Puncture Tray (Adult & Pediatric)
PXB
Percutaneous Introducer Kit
PXI
Thoracentesis Tray
PXJ
Umbilical Catheter Insertion Tray
PXK
Vascular Access Port Kit
PXL
Venipuncture Kit
PYR
Neuraxial Administration Set - Intrathecal Delivery
PZW
Catheter Access Cover, Tamper-Resistant
QBL
Piston Syringe Lever
QDM
Midazolam Syringe
QEH
Piston Syringe With Neuraxial Connector – Epidural, Peripheral, And/Or Indirect Cerebral Spinal Fluid Contact
QJY
Infusion Pump, Drug Specific, Pharmacy-Filled
QLF
On-Body Injector
QLY
Ophthalmic Syringe
QMT
Prep Kit – Vaccine Injection
QNQ
Low Dead Space Piston Syringe
QNS
Low Dead Space Needle, Single Lumen, Hypodermic
QOG
Injection Data Capture Device
QOI
Intravenous Catheter Force-Activated Separation Device.
QTI
Saline Vascular Access Flush With Integrated Alcohol Disinfectant Device
QYM
Ophthalmic Needle
SCL
Allergen And Vaccine Delivery Needles
SEF
Central Venous Catheter With Manual Insertion System
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
Subpart F—Therapeutic Devices
Subpart G—General Hospital and Personal Use Miscellaneous Devices
Subpart G—Miscellaneous Devices
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
HO
/
subpart-f—general-hospital-and-personal-use-therapeutic-devices
/
FOZ
/
K944367
View Source
CATCO POLYURETHANE UMBILICAL VESSEL CATHETER
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K944367
510(k) Type
Traditional
Applicant
CATCO MEDICAL, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
4/5/1995
Days to Decision
210 days
Submission Type
Statement