CAK · Microfilter, Blood Transfusion

General Hospital · 21 CFR 880.5440 · Class 2

Overview

Product CodeCAK
Device NameMicrofilter, Blood Transfusion
Regulation21 CFR 880.5440
Device ClassClass 2
Review PanelGeneral Hospital

Identification

An intravascular administration set is a device used to administer fluids from a container to a patient's vascular system through a needle or catheter inserted into a vein. The device may include the needle or catheter, tubing, a flow regulator, a drip chamber, an infusion line filter, an I.V. set stopcock, fluid delivery tubing, connectors between parts of the set, a side tube with a cap to serve as an injection site, and a hollow spike to penetrate and connect the tubing to an I.V. bag or other infusion fluid container.

Classification Rationale

Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

Special Controls

*Classification.* Class II (special controls). The special control for pharmacy compounding systems within this classification is the FDA guidance document entitled “Class II Special Controls Guidance Document: Pharmacy Compounding Systems; Final Guidance for Industry and FDA Reviewers.” Pharmacy compounding systems classified within the intravascular administration set are exempt from the premarket notification procedures in subpart E of this part and subject to the limitations in § 880.9.

Recent Cleared Devices (20 of 36)

Showing 20 most recent of 36 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K061103HAEMONETICS 40U RBC FILTER BAGHaemonetics Corp.May 17, 2006SESE
K022477SUMMIT MEDICAL LTD TRANSFUSION FILTER, MODEL LF400 & SUMMIT MEDICAL LTD TRANSFUSION FILTER WITH ADMINISTRATION SETSummit Medical , Ltd.Oct 25, 2002SESE
K000719NEOCARE 20 MICRON BLOOD FILTERWhatman, Inc.May 30, 2000SESE
K990310CHARTER MEDICAL, LTD MP 450 (40 MICRON FILTER)Charter Medical, Ltd.Aug 30, 1999SESE
K982822FENWAL 20 MICRON PEDIATRIC TRANSFUSION FILTER MODEL 4C7701, FENWAL 20 MICRON PEDIATRIC TRANSFUSION FILTER SET MODEL 4C72Baxter Healthcare CorpSep 30, 1998SESE
K972159FENWAL 40 MICRON TRANSFUSION FILTERBaxter Healthcare CorpJul 23, 1997SESE
K970225ALPHA MICRON 20/40 MICROAGGREGATE FILTERAlpha Therapeutic Corp.Feb 14, 1997SESE
K960993PALL SQ40S BLOOD FILTER (SQ40S/SQ40ST)Pall Biomedical Products Co.Apr 22, 1996SESE
K955515ALPHA MICRON 20 MICROAGGREGATE FILTERAlpha Therapeutic Corp.Feb 12, 1996SESE
K904223SEPACELL(R) R-200/500 LEUKOCYTE REMOVAL RECIP SETSBaxter Healthcare CorpOct 26, 1990SESE
K904221SEPACELL(R) PL-5A/10A LEUKOCYTE REMOVAL FILTERSBaxter Healthcare CorpOct 26, 1990SESE
K901887MODIFIED SEPACELL R-SERIES BLOOD FILTERSAsahi Medical Co., Ltd.Aug 8, 1990SESE
K896203SOLCOSEPT(TM) BLOOD TRANSFUSION FILTERSolco Basle, Inc.Feb 1, 1990SESE
K896976MODIFIED SEPACELL R-500 AND R-500A BLOOD FILTERSAsahi Medical Co., Ltd.Jan 24, 1990SESE
K896664MODIFIED SEPACELL PL-SERIES LEUKOCYTE REMOVAL FILTAsahi Medical Co., Ltd.Jan 24, 1990SESE
K890844MICROSEPT 60/20Arbor Technologies, Inc.Jun 7, 1989SESE
K873792SEPACELL R-500 AND SEPACELL R-500AAdvocacy International, Ltd.Jan 19, 1988SESE
K873667PALL LEUKOCYTE REMOVAL FILTER, PLATELETSPall Biomedical Products Co.Jan 6, 1988SESE
K873666PALL LEUKOCYTE REMOVAL FILTER, BLOODPall Biomedical Products Co.Jan 6, 1988SESE
K873873RESUBMITTED MICRON TRANSFUSION FILTERTravenol Laboratories, S.A.Oct 22, 1987SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...