21 CFR 876.5820 — Dialyzer, Single Coil
Gastroenterology, Urology (GU) · Subpart F—Therapeutic Devices · § 876.5820
Identification
A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.
Classification Rationale
(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.
Product Codes
| Product Code | Device Name | Class | Devices | Attributes |
|---|---|---|---|---|
| FHS | Dialyzer, Single Coil | 2 | 12 | Life-Sustaining |
| FIA | Chair, Dialysis, Unpowered, Without Scales | 1 | 0 | |
| FIB | Protector, Transducer, Dialysis | 2 | 35 | Life-Sustaining |
| FID | Tubing, Dialysate | 2 | 3 | Life-Sustaining |
| FIF | Set, Dialysis, Single Needle With Uni-Directional Pump | 2 | 6 | Life-Sustaining |
| FIG | Clamp, Tubing, Blood, Automatic | 2 | 4 | Life-Sustaining |
| FIH | Pump, Infusion Or Syringe, Extra-Luminal | 2 | 5 | Life-Sustaining |
| FIJ | System, Dialysate Delivery, Recirculating, Single Pass | 2 | 1 | Life-Sustaining |
| FIK | System, Dialysate Delivery, Recirculating | 2 | 0 | Life-Sustaining |
| FIL | System, Dialysate Delivery, Single Pass | 2 | 8 | Life-Sustaining |
| FIN | Tank, Holding, Dialysis | 2 | 18 | 3rd Party |
| FIR | Pump, Blood, Extra-Luminal | 2 | 7 | Life-Sustaining |
| FIS | Flowmeter, Dialysate | 2 | 0 | Life-Sustaining |
| FIW | Alarm, Pillow Pressure | 2 | 1 | Life-Sustaining |
| FIZ | Meter, Conductivity, Non-Remote | 2 | 13 | Life-Sustaining |
| FJA | Manometer, Water | 2 | 0 | 3rd Party |
| FJB | Detector, Dialysate Level | 2 | 3 | Life-Sustaining |
| FJC | Detector, Blood Level | 2 | 1 | Life-Sustaining |
| FJD | Detector, Leak, Blood | 2 | 4 | Life-Sustaining |
| FJF | Detector, Air Bubble | 2 | 5 | Life-Sustaining |
| FJG | Dialyzer, Parallel Flow | 2 | 36 | Life-Sustaining |
| FJI | Dialyzer, Capillary, Hollow Fiber | 2 | 131 | Life-Sustaining |
| FJJ | Dialyzer, Twin Coil | 2 | 0 | Life-Sustaining |
| FJK | Set, Tubing, Blood, With And Without Anti-Regurgitation Valve | 2 | 77 | Life-Sustaining |
| FJP | Adaptor, Y | 2 | 0 | 3rd Party |
| FJT | Intracatheter, Dialysis | 2 | 5 | Life-Sustaining |
| FJZ | Declotting Tray, Kit (Including Contents) | 2 | 3 | 3rd Party |
| FKB | Connector, Blood Tubing, Infusion T | 2 | 2 | Life-Sustaining |
| FKD | Canister, Coil | 2 | 1 | Life-Sustaining |
| FKE | Tie, Dialysis | 1 | 0 | |
| FKF | Gun, Tie, Dialysis | 1 | 0 | |
| FKG | Tray, Start/Stop (Including Contents), Dialysis | 1 | 6 | |
| FKH | Solution-Test Standard-Conductivity, Dialysis | 2 | 8 | 3rd Party |
| FKI | Set, Dialyzer Holder | 2 | 3 | |
| FKJ | Filter, Blood, Dialysis | 2 | 5 | Life-Sustaining |
| FKL | Insert, Pump, Blood | 2 | 1 | Life-Sustaining |
| FKM | Adaptor, Fistula | 2 | 0 | 3rd Party |
| FKP | System, Dialysate Delivery, Single Patient | 2 | 50 | Life-Sustaining |
| FKQ | System, Dialysate Delivery, Central Multiple Patient | 2 | 61 | Life-Sustaining |
| FKR | Subsystem, Proportioning | 2 | 12 | Life-Sustaining |
| FKY | Connector, Tubing, Dialysate | 2 | 4 | Life-Sustaining |
| FLA | Monitor, Temperature, Dialysis | 2 | 3 | Life-Sustaining |
| FLB | Meter, Conductivity, Induction, Remote Type | 2 | 6 | 3rd Party |
| FLC | Station, Dialysis Control, Negative Pressure Type | 2 | 4 | Life-Sustaining |
| KOC | Accessories, Blood Circuit, Hemodialysis | 2 | 182 | Life-Sustaining |
| KPO | Dialysate Concentrate For Hemodialysis (Liquid Or Powder) | 2 | 123 | Life-Sustaining |
| KQQ | Tubing, Dialysate (And Connector) | 2 | 1 | Life-Sustaining |
| KQR | Detector, Air Or Foam | 2 | 0 | Life-Sustaining |
| KXM | System Accessories, Extracorporeal | 2 | 4 | Life-Sustaining |
| LIF | Dialyzer Reprocessing System | 2 | 57 | |
| LLB | System, Blood, Extracorporeal And Accessories | 2 | 2 | Life-Sustaining |
| LRI | Ph Meter For Dialysis Hydrogen Ion Concentration | 2 | 1 | Life-Sustaining |
| MNV | Strip, Dialysate Ph Indicator | 2 | 6 | 3rd Party |
| MON | System, Hemodialysis, Remote Accessories | 1 | 0 | |
| MQS | System, Hemodialysis, Access Recirculation Monitoring | 2 | 18 | Life-Sustaining |
| MSE | Hemodialyzer, Re-Use, Low Flux | 2 | 7 | Life-Sustaining |
| NNG | Set, Dialysis, Single Needle With Uni-Directional Pump, Reprocessed | 2 | 0 | |
| NTZ | Strip, Dialysate, Ph, Bicarbonate, Glucose, Acid, Indicator | 2 | 1 | |
| ODX | Autonomous Extracorporeal Blood Leak Detector/Alarm | 2 | 4 | |
| PEV | Dialysis Administration Kit | 2 | 0 | |
| PPH | Single Needle With Uni-Directional Pump Kit | 2 | 0 | |
| PPI | Hemodialysis Tray (Not A Start/Stop Kit) | 2 | 0 | |
| PPL | Single Needle (Co-Axial Flow) Dialysis Kit | 2 | 0 | |
| PRO | Anti-Regurgitation Blood Tubing Kit | 2 | 0 |