FJI · Dialyzer, Capillary, Hollow Fiber

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeFJI
Device NameDialyzer, Capillary, Hollow Fiber
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 131)

Showing 20 most recent of 131 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K190459Hemoflow F3 and F4 DialyzersFresenius Medical Care Renal Therapies Group, LLCAug 23, 2019SESE
K122952NIPRO PUREFLUX-L HEMODIALYZERNipro Medical CorporationDec 4, 2013SESE
K043342POLYFLUX FAMILY HEMODIALYZER/FILTER LABELED FOR SINGLE AND MULTIPLE USE, MODELS 14L, 17L, 21L, 140H, 170H, 210H,6LR, 8LRGambro Renal ProductsMay 27, 2005SESE
K010366DISPOSABLE STORAGE CAPMolded Products, Inc.Nov 28, 2001SESE
K011148ULTRACONCENTRATOR SYSTEMInterpore Cross Intl.Jun 13, 2001SESE
K002761FRESNIUS HEMOFLOW F7NR, F50NR, F70NR HEMODIALYZERSFresenius Medical Care North AmericaDec 4, 2000SESE
K991908IDEMSA HEMOPHAN HOLLOW FIBER DIALYZERSIdemsaApr 17, 2000SESE
K992594A-15 HEMODIALYZERAlthin Medical ABSep 24, 1999SESE
K992565A-18 HEMODIALYZERAlthin Medical ABSep 23, 1999SESE
K991512ASAHI AM-R-SERIES DIALYZERS (MODIFIED), MODEL AM-NR-XAsahi Medical Co., Ltd.Jul 29, 1999SESE
K990159DYNAMIC HOLLOW FIBER DIALYZER DH-SERIES, MODEL AH 90111Dynamic Technology Corp.Apr 19, 1999SESE
K982337CUPROPHAN AND HEMOPHAN HOLLOW FIBER DIALYZERHaidylena Medical EgyptDec 29, 1998SESE
K981253ULTRACON ULTRAFILTRATORInterpore Intl.Dec 11, 1998SESE
K980658PSN DIALYZER, MODEL PSN 130/R5M4233, MODEL PSN-150/R5M4234Baxter Healthcare CorpMay 19, 1998SESE
K971710ULTRACON ULTRAFILTRATORQuantic Biomedical, Inc.Feb 27, 1998SESE
K973291DYNAMIC HOLLOW FIBER DIALYZER DC-SERIESDynamic Technology Corp.Dec 19, 1997SESE
K970708CLIRANS T-SERIES HOLLOW FIBER DIALYZERSTerumo Medical Corp.Dec 19, 1997SESE
K963933PSN-120 HOLLOW FIBER DIALYZER AND PSN-140 HOLLOW FIBER DIALYZERBaxter Healthcare CorpNov 24, 1997SESE
K962309ALTERNATE ENCAPSULATING RESIN SYSTEM FOR MCA HEMODIALYZERSAlthin Medical AB an Affiliate of Baxter IntlDec 27, 1996SESE
K961039BLLOD PORT CAP, DIALYSATE PORT CAP, VENTED DIALYSATE PORT CAP WITH RED PLIABLE VINYLDayspring Medical, Inc.Sep 12, 1996SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...