FIB · Protector, Transducer, Dialysis

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeFIB
Device NameProtector, Transducer, Dialysis
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology
Life-SustainingYes

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 35)

Showing 20 most recent of 35 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K240164NovaLine SP-C35 Transducer Protector (956007)Bain Medical Equipment (Guangzhou) Co., Ltd.Jun 28, 2024SESE
K072988NIPRO TRANSDUCER PROTECTOR TP-SURE, MODEL TPSURE+1Nipro Medical CorporationFeb 21, 2008SESE
K001971HEMODIALYSIS TUBING SETSOfi Biomedica S.P.A.May 24, 2001SESE
K010264NIPRO BLOOD TUBING SET FOR HEMODIALYSIS WITH TRANSDUCER PROTECTORS AND PRIMING SETNipro Medical Corp.Apr 27, 2001SESE
K001465NIPRO BLOOD TUBING SET FOR HEMODIALYSIS WITH TRANSDUCER PROTECTORS AND PRIMING SETNipro Medical Corp.Dec 5, 2000SESE
K003445FRESENIUS VIRAL BLOCKING TRANSDUCER PROTECTOR FOR HEMODIALYSIS, MODEL 04-9500-2Fresenius Medical Care North AmericaDec 1, 2000SESE
K000702BORLA TRANSDUCER PROTECTOR & HAEMOTRONIC TRANSDUCER PROTECTORFresenius Medical Care North AmericaJun 7, 2000SESE
K983076MEDISYSTEMS TRANSDUCER PROTECTORMedisystems Corp.Nov 25, 1998SESE
K964337BETTER-BLADDER (BB)Circulatory Technology, Inc.May 23, 1997SESE
K970536MEDISYSTEMS TRANDUCER PROTECTORMedisystems Corp.May 12, 1997SESE
K934069MILLEX, DUALEX (PLUS, ULTRA)Millipore Corp.Apr 21, 1994SESE
K925978MPC-80 TRANSDUCERMolded Products, Inc.Jan 14, 1994SESE
K915593TRANSDUCER PROTECTORUnited Pharmaceutical and Medical Supply Co.Jul 1, 1992SESE
K912394TRANSDUCER PROTECTORFiltertek, Inc.Aug 30, 1991SESE
K911658DIALYSIS TRANDSDUCER PROTECTORTico Medical Instruments, Inc.Aug 12, 1991SESE
K910821TRANSDUCER PROTECTORGelman Sciences, Inc.Aug 12, 1991SESE
K904912TRANSDUCER PROTECTORFiltertek, Inc.Jan 4, 1991SESE
K902788CLEM TMArbo Medical, Inc.Sep 12, 1990SESE
K901409TRANSDUCER PROTECTORFiltertek, Inc.Jul 27, 1990SESE
K901996FILTERTEK PN 60650 DIALYSIS TRANSDUCER PROTECTORFiltertek, Inc.Jun 1, 1990SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...