LIF · Dialyzer Reprocessing System

Gastroenterology, Urology · 21 CFR 876.5820 · Class 2

Overview

Product CodeLIF
Device NameDialyzer Reprocessing System
Regulation21 CFR 876.5820
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

A hemodialysis system and accessories is a device that is used as an artificial kidney system for the treatment of patients with renal failure or toxemic conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system and accessories to the blood compartment of the dialyzer, then returns through further tubing of the extracorporeal blood system to the patient. The dialyzer has two compartments that are separated by a semipermeable membrane. While the blood is in the blood compartment, undesirable substances in the blood pass through the semipermeable membrane into the dialysate in the dialysate compartment. The dialysate delivery system controls and monitors the dialysate circulating through the dialysate compartment of the dialyzer.(1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air foam or bubble detectors, and alarms to keep blood moving safely from the blood access device and accessories for hemodialysis (§ 876.5540) to the blood compartment of the dialyzer and back to the patient. (2) The conventional dialyzer allows a transfer of water and solutes between the blood and the dialysate through the semipermeable membrane. The semipermeable membrane of the conventional dialyzer has a sufficiently low permeability to water that an ultrafiltration controller is not required to prevent excessive loss of water from the patient's blood. This conventional dialyzer does not include hemodialyzers with the disposable inserts (Kiil type) (§ 876.5830) or dialyzers of high permeability (§ 876.5860). (3) The dialysate delivery system consists of mechanisms that monitor and control the temperature, conductivity, flow rate, and pressure of the dialysate and circulates dialysate through the dialysate compartment of the dialyzer. The dialysate delivery system includes the dialysate concentrate for hemodialysis (liquid or powder) and alarms to indicate abnormal dialysate conditions. This dialysate delivery system does not include the sorbent regenerated dialysate delivery system for hemodialysis (§ 876.5600), the dialysate delivery system of the peritoneal dialysis system and accessories (§ 876.5630), or the controlled dialysate delivery system of the high permeability hemodialysis system § 876.5860). (4) Remote accessories to the hemodialysis system include the unpowered dialysis chair without a scale, the powered dialysis chair without a scale, the dialyzer holder set, dialysis tie gun and ties, and hemodialysis start/stop tray.

Classification Rationale

(1) Class II (performance standards) for hemodialysis systems and all accessories directly associated with the extracorporeal blood system and the dialysate delivery system.(2) Class I for other accessories of the hemodialysis system remote from the extracorporeal blood system and the dialysate delivery system, such as the unpowered dialysis chair, hemodialysis start/stop tray, dialyzer holder set, and dialysis tie gun and ties. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 57)

Showing 20 most recent of 57 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K091360CLEARFLUX DIALYZER REPROCESSING SYSTEMNovaflux TechnologiesNov 3, 2010SESE
K043126ASSIST HEADER CLEANERAlcavis International, Inc.Feb 3, 2005SESE
K040660STERICHEK GLUTARALDEHYDE REAGENT STRIPSHach CompanyNov 15, 2004SESE
K033505RENACLEAN SH DIALYZER CLEANING SYSTEMMinntech Corp.Apr 27, 2004SESE
K024076MAKY 21.1 DIALYZER REPROCESSING SYSTEMHdc Maquinolas, LLCSep 26, 2003SESE
K013713ARM AUTOMATIC REPROCESSING MACHINEAlcavis International IncorporatedJul 15, 2002SESE
K992016AMUKIN DAmuchina Intl., Inc.Jan 10, 2000SESE
K991851RENACLEAR DIALYZER CLEANING SYSTEMMinntech Corp.Aug 30, 1999SESE
K974426POTENCY TEST STRIPS, INDICATOR TEST STRIPSReprocessing Products CorpFeb 10, 1999SESE
K974798STERICHEK(TM) RESIDUAL PEROXIDE REAGENT STRPSEnvironmental Test Systems, Inc.Mar 20, 1998SESE
K970799ALEXANDER MANUFACTURING RECHARGEABLE BATTERY (M1/T)Alexander Mfg. Co.May 14, 1997SESE
K955299DPS 4 DIALYZER PREPARATION SYSTEMSeratronics, Inc.Oct 21, 1996SESE
K931336DRS 4 DIALYZER REPROCESSING SYSTEMSeratronics, Inc.Apr 18, 1996SESE
K941867RENALIN REUSE CARTRenal Scientific Service, Inc.Jan 22, 1996SESE
K941757FORMALIN REUSE CARTNational Medical Care, Medical Products Div., Inc.Jan 22, 1996SESE
K944539DRS 4 ND DIALYZER REPROCESSING SYSTEMSeratronics, Inc.Nov 29, 1995SESE
K944492DIALYZER REPROCESSING SYSTEMG.E.M. Water SystemsAug 28, 1995SESE
K923529DMS DATA MANAGEMENT SYSTEM/DRS-4 DIALYZER REPROCESSeratronics, Inc.Aug 29, 1994SESE
K914123SERIM RESIDUAL FORMALDEHYDE REAGENT STRIPSSerim Research Corp.Apr 9, 1992SESE
K914580DRS-4 DIALYZER REPROCESSING SYSTEMSeratronics, Inc.Feb 24, 1992SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...