← Product Code [EBI](/submissions/DE/subpart-d%E2%80%94prosthetic-devices/EBI) · K964040 # TRUBYTE SOFT RELINE SYSTEM (K964040) _Dentsply Intl. · EBI · Dec 6, 1996 · Dental · SESE_ **Canonical URL:** https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/EBI/K964040 ## Device Facts - **Applicant:** Dentsply Intl. - **Product Code:** [EBI](/submissions/DE/subpart-d%E2%80%94prosthetic-devices/EBI.md) - **Decision Date:** Dec 6, 1996 - **Decision:** SESE - **Submission Type:** Traditional - **Regulation:** 21 CFR 872.3760 - **Device Class:** Class 2 - **Review Panel:** Dental - **Attributes:** Therapeutic ## Intended Use The TRUBYTE® SOFT RELINE SYSTEM is for use as a long-term resilient lining material for removable dentures. ## Device Story System comprises silicone putty (Soft Refine Material), methacrylate-based liquid (Soft Refine Bonder), and D-Limonene solvent (Adhesive Remover). Used by dental professionals to reline removable dentures. Process: clean denture with Adhesive Remover; apply Bonder; pack and compress silicone putty; heat cure. Provides resilient lining to improve denture fit and patient comfort. Components utilize established dental materials; safety validated via biocompatibility testing. ## Clinical Evidence Bench testing only. Biocompatibility testing performed: Cytotoxicity Elution Test, Primary Skin Irritation Study, Salmonella Mutagenicity Test, FHSA Regulation Acute Mucosal, and Kligman Maximization Study. Results confirmed material is non-cytotoxic, non-irritant, non-mutagenic, and non-sensitizer. ## Technological Characteristics Silicone elastomer putty (heat polymerizable); methacrylate monomer/polymer blend bonder; D-Limonene solvent. Heat-cured system. Materials previously used in predicate dental devices. ## Regulatory Identification A denture relining, repairing, or rebasing resin is a device composed of materials such as methylmethacrylate, intended to reline a denture surface that contacts tissue, to repair a fractured denture, or to form a new denture base. This device is not available for over-the-counter (OTC) use. ## Predicate Devices - New Per-Fit Improved ([K901621](/device/K901621.md)) - Molloplast B (Unknown) - PermaSoft ([K933468](/device/K933468.md)) ## Reference Devices - Triad® DuaLine™ Material ([K926406](/device/K926406.md)) - Lucitone® 199 Denture Base (Pre-1976) - Precise™ Denture Base ([K952351](/device/K952351.md)) - Kadon (Pre-1976) ## Related Devices - [K112445](/device/K112445.md) — SOFRELINER TOUGH S · Tokuyama Dental Corporation · Oct 28, 2011 - [K111178](/device/K111178.md) — JUELL SOFT CURE · Juell Dental · Sep 12, 2011 - [K981691](/device/K981691.md) — SILICONE SOFT RELINE · Harry J. Bosworth Co. · Nov 3, 1998 - [K060844](/device/K060844.md) — SILKLINE SOFT RELINING KIT, MODEL 28-100100 · J. Morita USA, Inc. · Jun 6, 2006 - [K153253](/device/K153253.md) — GC Reline II · GC America, Inc. · Mar 3, 2016 ## Submission Summary (Full Text) {0} K964040 DEC -6 1996 510(k) SUMMARY DENTSPLY NAME & ADDRESS: DENTSPLY International 570 West College Avenue P.O. Box 872 York, PA 17405-0872 [717] 845-7511 Fax [717] 854-2343 P. J. Lehn Telefax (717) 849-4343 CONTACT: P. Jeffery Lehn DATE PREPARED: September 26, 1996 TRADE NAME: TRUBYTE® SOFT RELINE SYSTEM CLASSIFICATION NAME: Relining, repairing or rebasing denture base resin PREDICATE DEVICES: New Per-Fit Improved K901621 Molloplast B Unknown PermaSoft K933468 DEVICE DESCRIPTION: The TRUBYTE® SOFT RELINE SYSTEM consists of three components: TRUBYTE® Soft Refine Material, TRUBYTE® Soft Refine Bonder, and TRUBYTE® Adhesive Remover. TRUBYTE® Soft Refine Material is a silicone putty that is heat polymerizable. It is a one-component material based on an elastomer and benzoyl peroxide. TRUBYTE® Soft Refine Bonder is a heat polymerizable methacrylate monomer and methacrylate polymer blend liquid. TRUBYTE® Adhesive Remover is D-Limonene, a liquid food-grade solvent, intended for use in removing impression material tray adhesives. TRUBYTE® Soft Refine Material is bonded to the denture with the TRUBYTE® Soft Refine Bonder, packed and compressed, and then heat cured. TRUBYTE® Adhesive Remover is used to clean an existing denture prior to refining. The Adhesive is completely eliminated prior to using Soft Refine Material and Bonder. INTENDED USE: The TRUBYTE® SOFT RELINE SYSTEM is for use as a long-term resilient lining material for removable dentures. TECHNOLOGICAL CHARACTERISTICS: All of the components of the TRUBYTE® SOFT RELINE SYSTEM have been used in DENTSPLY predicate devices: Triad® DuaLine™ Material (K926406), Lucitone® 199 Denture Base (Pre-1976 Device), Precise™ Denture Base (K952351), and Kadon (Pre-1976 Device). 000013 {1} 510(k) SUMMARY (cont'd.) Page 2 of 2 # TRADE NAME: TRUBYTE® SOFT RELINE SYSTEM TRUBYTE® SOFT RELINE MATERIAL was evaluated and found to be non-cytotoxic, a non-irritant, non-mutagenic and a non-sensitizer. The following tests were performed on the MATERIAL: Cytotoxicity Elution Test, Primary Skin Irritation Study, Salmonella Mutagenicity Test, FHSA Regulation Acute Mucosal, and Kligman Maximization Study. The BONDER, used with the cured MATERIAL and Lucitone® 199 Denture Base, was tested by the Cytotoxicity Elution Test and found to be non-cytotoxic. We believe that the prior use of the TRUBYTE® SOFT RELINE SYSTEM's components in predicate devices, the performance data presented, and the results of toxicity and sensitization testing support the safety and effectiveness of TRUBYTE® SOFT RELINE SYSTEM for the intended use. 000014 --- **Source:** [https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/EBI/K964040](https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/EBI/K964040) **Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact). **Cite as:** FDA Device Explorer (Innolitics), https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/EBI/K964040
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...