FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
NDH
Nail, Fixation, Bone, Metallic
2
Product Code
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
3
Product Code
HSA
Prosthesis, Knee, Hemi-, Femoral
3
Product Code
HSB
Rod, Fixation, Intramedullary And Accessories
2
Product Code
NDI
Staple, Fixation, Bone, Metallic
2
Product Code
HRS
Plate, Fixation, Bone
2
Product Code
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
2
Product Code
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
2
Product Code
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
2
Product Code
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
2
Product Code
HTN
Washer, Bolt Nut
2
Product Code
HTY
Pin, Fixation, Smooth
2
Product Code
HWC
Screw, Fixation, Bone
2
Product Code
HXA
Prosthesis, Tendon, Passive
2
Product Code
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
2
Product Code
JDC
Prosthesis, Elbow, Constrained, Cemented
2
Product Code
JDD
Prosthesis, Upper Femoral
2
Product Code
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
2
Product Code
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
3
Product Code
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
2
Product Code
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
3
Product Code
JDN
Implant, Fixation Device, Spinal
2
Product Code
JDO
Device, Fixation, Proximal Femoral, Implant
2
Product Code
JDP
Condylar Plate Fixation Implant
2
Product Code
JDQ
Cerclage, Fixation
2
Product Code
JDR
Staple, Fixation, Bone
2
Product Code
JDS
Nail, Fixation, Bone
2
Product Code
JDT
Cap, Bone
1
Product Code
JDW
Pin, Fixation, Threaded
2
Product Code
JEC
Component, Traction, Invasive
2
Product Code
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
2
Product Code
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
2
Product Code
KIG
Prosthesis, Wrist, Constrained, Polymer
2
Product Code
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
2
Product Code
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
2
Product Code
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
3
Product Code
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
2
Product Code
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
3
Product Code
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
3
Product Code
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
2
Product Code
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
2
Product Code
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
2
Product Code
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
3
Product Code
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
3
Product Code
KWD
Prosthesis, Toe, Hemi-, Phalangeal
2
Product Code
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
3
Product Code
KWF
Prosthesis, Finger, Polymer
2
Product Code
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
3
Product Code
KWH
Prosthesis, Toe, Constrained, Polymer
2
Product Code
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
2
Product Code
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
3
Product Code
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
2
Product Code
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
2
Product Code
KWM
Prosthesis, Wrist, Semi-Constrained
2
Product Code
KWN
Prosthesis, Wrist, Carpal Lunate
2
Product Code
KWO
Prosthesis, Wrist, Carpal Scaphoid
2
Product Code
KWP
Appliance, Fixation, Spinal Interlaminal
2
Product Code
KWQ
Appliance, Fixation, Spinal Intervertebral Body
2
Product Code
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
3
Product Code
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
2
Product Code
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
2
Product Code
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
2
Product Code
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
2
Product Code
KXA
Prosthesis, Hip, Femoral, Resurfacing
2
Product Code
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
3
Product Code
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
3
Product Code
KXD
Prosthesis, Hip, Constrained, Metal
3
Product Code
KXE
Prosthesis, Wrist, Hemi-, Ulnar
2
Product Code
KYI
Prosthesis, Wrist, Carpal Trapezium
2
Product Code
KYJ
Prosthesis, Finger, Constrained, Polymer
2
Product Code
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
3
Product Code
KYN
Prosthesis, Wrist, Constrained, Metal
3
Product Code
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
3
Product Code
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
2
Product Code
LOD
Bone Cement
2
Product Code
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
2
Product Code
LRN
Wire, Surgical
2
Product Code
LTO
Spacer, Cement
3
Product Code
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
2
Product Code
LYP
Accessories, Fixation, Spinal Interlaminal
2
Product Code
LYT
Fixation Accessory
2
Product Code
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
2
Product Code
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
2
Product Code
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
2
Product Code
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
2
Product Code
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
2
Product Code
MBB
Bone Cement, Antibiotic
2
Product Code
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
2
Product Code
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
2
Product Code
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
2
Product Code
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
2
Product Code
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
2
Product Code
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
2
Product Code
MJW
Prosthesis, Subtalar, Plug, Polymer
2
Product Code
MNH
Orthosis, Spondylolisthesis Spinal Fixation
2
Product Code
MNI
Orthosis, Spinal Pedicle Fixation
2
Product Code
MNU
Staple, Absorbable
2
Product Code
MQP
Spinal Vertebral Body Replacement Device
2
Product Code
MQV
Filler, Bone Void, Calcium Compound
2
Product Code
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
2
Product Code
NDD
Cerclage, Fixation, Metallic
2
Product Code
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
2
Product Code
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
2
Product Code
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDK
System, External Fixator (With Metallic Invasive Components)
2
Product Code
NDL
Pin, Fixation, Smooth, Metallic
2
Product Code
NDM
Pin, Fixation, Threaded, Metallic
2
Product Code
NDN
Cement, Bone, Vertebroplasty
2
Product Code
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
2
Product Code
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
2
Product Code
NKB
Thoracolumbosacral Pedicle Screw System
2
Product Code
NKG
Posterior Cervical Screw System
2
Product Code
NOV
Anchor, Suture, Bone Fixation, Metallic
2
Product Code
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
NQP
Posterior Metal/Polymer Spinal System, Fusion
2
Product Code
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
2
Product Code
NUD
Vertebroplasty Compound, Calcium Based
2
Product Code
NVC
Bone, Heterograft
3
Product Code
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
2
Product Code
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
2
Product Code
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
2
Product Code
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
2
Product Code
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
3
Product Code
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
2
Product Code
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
2
Product Code
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
2
Product Code
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
2
Product Code
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
2
Product Code
OOG
Knee Arthroplasty Implantation System
2
Product Code
OOL
Electronic Depth Gauge
2
Product Code
OQB
Intervertebral Body Graft Containment Device
2
Product Code
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
2
Product Code
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
2
Product Code
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
2
Product Code
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
2
Product Code
OSN
Software For Diagnosis/Treatment
2
Product Code
OUR
Sacroiliac Joint Fixation
2
Product Code
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
2
Product Code
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
2
Product Code
OVZ
Pin, Fixation, Resorbable, Hard Tissue
2
Product Code
OWI
Bone Fixation Cerclage, Sublaminar
2
Product Code
OYK
Ankle Arthroplasty Implantation System
2
Product Code
OZI
Internal Hinged Elbow Fixator
2
Product Code
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
2
Product Code
PBF
Orthopaedic Surgical Planning And Instrument Guides
2
Product Code
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
2
Product Code
PEK
Spinous Process Plate
2
Product Code
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
2
Product Code
PHQ
Anterior Staple As Supplemental Fixation For Fusion
2
Product Code
PHX
Shoulder Prosthesis, Reverse Configuration
2
Product Code
K
25
2567
AltiVate Reverse® ADLC Glenosphere
2
Cleared 510(K)
K
25
2516
N22 EZ Glenosphere
2
Cleared 510(K)
K
25
4003
JARVIS Metaphyseal Stem
2
Cleared 510(K)
K
25
2788
Tornier Perform™ Reversed Monopost Glenoid (Perform Mono)
2
Cleared 510(K)
K
25
0338
MSS - Humeral reverse liners extension
2
Cleared 510(K)
K
25
3345
JARVIS Diaphyseal Stem Standard
2
Cleared 510(K)
K
25
2411
JARVIS Glenoid Reverse Shoulder Prosthesis
2
Cleared 510(K)
K
25
2141
AltiVate Reverse® Glenoid
2
Cleared 510(K)
K
24
3448
Equinoxe® Shoulder System
2
Cleared 510(K)
K
24
3826
SMR Reverse HP Shoulder System
2
Cleared 510(K)
K
24
3643
restor3d Reverse Total Shoulder Arthroplasty System
2
Cleared 510(K)
K
25
1184
AltiVate Reverse Shoulder System; RSP Shoulder System; SMR Shoulder System; PRIMA Humeral System; PRIMA Glenoid System
2
Cleared 510(K)
K
24
2253
JARVIS Glenoid Reverse Shoulder Prosthesis
2
Cleared 510(K)
K
24
1491
Blueprint Patient-Specific Instrumentation; Shoulder iD Primary Reversed Glenoid
2
Cleared 510(K)
K
23
3482
Equinoxe® Central Screw Baseplate System
2
Cleared 510(K)
K
23
3481
AltiVate Reverse® Glenoid
2
Cleared 510(K)
K
24
1043
Augment Off-Axis Instrument System
2
Cleared 510(K)
K
24
0278
Full Wedge Lateralized and Augmented Baseplates
2
Cleared 510(K)
K
23
4105
Catalyst F1x Shoulder System
2
Cleared 510(K)
K
23
3148
Augment Off-Axis Instrument System
2
Cleared 510(K)
K
23
2265
BLUEPRINT™ Patient Specific Instrumentation
2
Cleared 510(K)
K
23
1445
LINK Embrace Shoulder System - Reverse Configuration
2
Cleared 510(K)
K
23
1911
Glenoid Reconstruction System – Full Wedge Baseplate
2
Cleared 510(K)
K
23
2583
Catalyst R1 Reverse Shoulder System
2
Cleared 510(K)
K
22
3833
Exactech® Equinoxe® Reverse Humeral Liners and Humeral Adapter Trays
2
Cleared 510(K)
K
23
2226
ARROW Off-Centred Humeral Insert
2
Cleared 510(K)
K
22
3801
FX V135(TM) Shoulder Prosthesis
2
Cleared 510(K)
K
22
3655
Catalyst R1 Reverse Shoulder System
2
Cleared 510(K)
K
23
0366
Arthrex Univers Revers Monoblock Stem Size 4/33
2
Cleared 510(K)
K
21
4001
Comprehensive® Shoulder System, Comprehensive® Reverse Shoulder System
2
Cleared 510(K)
K
22
3211
INHANCETM Shoulder System – Humeral Stems and Stemless
2
Cleared 510(K)
K
21
3459
Glenoid Reconstruction System
2
Cleared 510(K)
K
22
2936
Humeris® 135 Shoulder System
2
Cleared 510(K)
K
22
0914
Tornier Perform Humeral System – Fracture
2
Cleared 510(K)
K
22
1467
INHANCETM Reverse Glenoid Peripheral Posts
2
Cleared 510(K)
K
21
3349
Catalyst R1 Reverse Shoulder System
2
Cleared 510(K)
K
21
3117
FX V135 Shoulder Prosthesis
2
Cleared 510(K)
K
21
2737
INHANCE™ Reverse Shoulder System
2
Cleared 510(K)
K
21
2800
PRIMA Humeral System and SMR Glenosphere Ø42
2
Cleared 510(K)
K
20
2024
ARROW Short Stem Humeral System
2
Cleared 510(K)
K
21
2992
LINK® Embrace Shoulder System - Reverse Configuration
2
Cleared 510(K)
K
21
2415
Arthrex Modular Glenoid System-Titanium Glenosphere
2
Cleared 510(K)
K
21
1359
Tornier Perform™ Patient-Matched Primary Reversed Glenoid and BLUEPRINT™ Patient Specific Instrumentation
2
Cleared 510(K)
K
21
1729
Comprehensive® Convertible Glenoid - Vivacit-E Liner
2
Cleared 510(K)
K
21
3124
Tomier Perform™ Reversed Glenoid Cannulated Glenospheres
2
Cleared 510(K)
K
21
2710
GLOBAL UNITE™ Platform Shoulder System
2
Cleared 510(K)
K
21
1074
Univers Revers Modular Glenoid System, Standard Augment Baseplates
2
Cleared 510(K)
K
21
0790
Lateralized and Augmented Baseplates
2
Cleared 510(K)
K
21
0533
Inset Reverse Total Shoulder System
2
Cleared 510(K)
K
21
1553
Tecomet Global Unite Short Stem Instrumentation
2
Cleared 510(K)
K
21
1991
Catalyst R1 Reverse Shoulder System
2
Cleared 510(K)
K
20
3694
DELTA XTEND Reverse Shoulder System
2
Cleared 510(K)
K
21
0717
Bone Screws dia. 5,0 mm
2
Cleared 510(K)
K
20
3375
OVOMotion Reverse Shoulder Arthroplasty System
2
Cleared 510(K)
K
21
0207
Humeral Eccentric Reverse Metaphysis
2
Cleared 510(K)
K
20
3755
Shoulder System - TiNbN Coating
2
Cleared 510(K)
K
21
0167
DELTA XTEND Reverse Shoulder System
2
Cleared 510(K)
K
20
2232
Comprehensive Vault Reconstruction System
2
Cleared 510(K)
K
20
2611
Catalyst OrthoScience R1 Reverse Shoulder System
2
Cleared 510(K)
K
20
0368
LINK Embrace Shoulder System - Reverse Configuration
2
Cleared 510(K)
K
20
2098
GLOBAL UNITE™ Platform Shoulder System
2
Cleared 510(K)
K
20
0171
SMR TT Augmented Glenoid System
2
Cleared 510(K)
K
20
0895
Univers Revers Modular Glenoid System, Half Augment Baseplate
2
Cleared 510(K)
K
19
3175
Lateralized Glenosphere
2
Cleared 510(K)
K
19
1146
Humelock TiN Coated Glenosphere
2
Cleared 510(K)
K
19
3394
Humeral Cup Stability & Humeral Cup 135/145o Stability
2
Cleared 510(K)
K
19
3373
Comprehensive® Reverse Shoulder
2
Cleared 510(K)
K
19
2967
Medacta Shoulder System
2
Cleared 510(K)
K
19
2855
DELTA XTEND(TM) Reverse Shoulder System
2
Cleared 510(K)
K
19
2799
Glenoid Baseplate with Screw
2
Cleared 510(K)
K
19
3098
Exactech® Equinoxe® Reverse Shoulder Glenospheres
2
Cleared 510(K)
K
19
3099
Anatomical Shoulder System
2
Cleared 510(K)
K
19
3372
Univers Revers Modular Glenoid System (Augemented baseplates)
2
Cleared 510(K)
K
19
1960
Arthrex Univers Revers Modular Glenoid System
2
Cleared 510(K)
K
19
0738
MyShoulder Placement Guides
2
Cleared 510(K)
K
19
0588
Integra TITAN Reverse Shoulder System
2
Cleared 510(K)
K
19
1746
SMR TT Augmented Glenoid System
2
Cleared 510(K)
K
19
2206
32mm Glenosphere and Humeral Cup
2
Cleared 510(K)
K
19
2448
Delta Xtend Revers Shoulder System
2
Cleared 510(K)
K
19
1561
Exactech Equinoxe Humeral Augmented Trays
2
Cleared 510(K)
K
18
3077
Delta Xtend Reverse Shoulder System
2
Cleared 510(K)
K
18
3696
Aequalis PerFORM Reversed Glenoid, Aequalis PerFORM + Reversed Glenoid
2
Cleared 510(K)
K
18
1826
Glenoid Polyaxial Non-locking Screws
2
Cleared 510(K)
K
18
2536
Exactech Equinoxe Small Reverse Shoulder Glenospheres , Exactech Equinoxe Reverse Shoulder Humeral Liners , Exactech Equinoxe Small Reverse Shoulder Glenoid Plates , Exactech Equinoxe Reverse Shoulder Locking Cap
2
Cleared 510(K)
K
18
1999
Integra TITAN Reverse Shoulder System
2
Cleared 510(K)
K
18
2039
Arthrex Univers Revers Porous Coated Baseplate and Universal Glenoid Inlay
2
Cleared 510(K)
K
18
1611
Comprehensive Reverse Shoulder System
2
Cleared 510(K)
K
18
0632
Exactech Equinoxe Small Reverse Shoulder System
2
Cleared 510(K)
K
17
3717
Integra TITAN Reverse Shoulder System
2
Cleared 510(K)
K
17
3900
Arthrex Univers Revers Modular Glenoid System
2
Cleared 510(K)
K
18
0089
Medacta Shoulder System Short Humeral Diaphysis
2
Cleared 510(K)
K
17
2371
Arthrex UNIVERS REVERS COATED BASEPLATE
2
Cleared 510(K)
K
17
3411
Comprehensive Segmental Revision System (SRS)
2
Cleared 510(K)
K
17
1789
ARROW Reverse Porous Glenoid
2
Cleared 510(K)
K
17
0748
GLOBAL UNITE Platform Shoulder System
2
Cleared 510(K)
K
17
2502
Comprehensive Augmented Glenoid Components, Comprehensive Standard Baseplate, Comprehensive Mini Baseplate
2
Cleared 510(K)
K
17
3073
AltiVate Anatomic to Reverse Conversion Module
2
Cleared 510(K)
K
17
0414
Arthrex Univers Revers Apex Humeral Stems
2
Cleared 510(K)
K
17
1058
Medacta Shoulder System: Threaded Glenoid Baseplate
2
Cleared 510(K)
K
17
2767
Zimmer Trabecular Metal Reverse Shoulder System, Mini Glenoid
2
Cleared 510(K)
K
17
0452
Medacta Shoulder System
2
Cleared 510(K)
K
17
0711
ASHCOM Shoulder System, Anatomical Shoulder System and Anatomical Shoulder Combined System
2
Cleared 510(K)
K
16
3669
Humeris Shoulder
2
Cleared 510(K)
K
16
2325
Exactech Equinoxe Reverse Shoulder Locking Cap, Exactech Equinoxe Reverse Shoulder Compression Screws, Exactech Equinoxe Reverse Shoulder Glenosphere Locking Screw
2
Cleared 510(K)
K
16
1120
SMR TT Metal Back Glenoid, Bone Graft instruments
2
Cleared 510(K)
K
16
2726
Exactech® Equinoxe® Preserve Stem
2
Cleared 510(K)
K
16
2455
Humelock Reversed Shoulder
2
Cleared 510(K)
K
16
1742
Aequalis PerFORM Reversed, Aequalis PerFORM+ Reversed Glenoid
2
Cleared 510(K)
K
16
1189
Integra TITAN Reverse Shoulder System
2
Cleared 510(K)
K
15
2754
COMPREHENSIVE VAULT RECONSTRUCTION SYSTEM (VRS)
2
Cleared 510(K)
K
15
2966
Aequalis Fx2
2
Cleared 510(K)
K
15
0488
Humelock II Reversible Shoulder System
2
Cleared 510(K)
K
15
0568
ARROW Humeral stems size 6 and 16
2
Cleared 510(K)
K
15
0458
Exactech Equinoxe Reverse Shoulder 46x21mm Glenosphere
2
Cleared 510(K)
K
14
2778
ARROW Reverse Shoulder long keel and short keel glenoid base
2
Cleared 510(K)
K
14
2863
Univers Rivers Shoulder Prosthesis System
2
Cleared 510(K)
K
14
1345
AEQUALIS FX2
2
Cleared 510(K)
K
14
2139
SMR 40MM GLENOSPHERE
2
Cleared 510(K)
K
14
1990
ENCORE HUMERAL SHOULDER STEM
2
Cleared 510(K)
K
14
0478
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
14
0082
AEQUALIS(TM) ASCENT(TM) FLEX SHOULDER SYSTEM
2
Cleared 510(K)
K
14
0652
POROUS COATED COMPREHENSIVE FRACTURE STEMS
2
Cleared 510(K)
K
14
1029
TORNIER AEQUALIS ADJUSTABLE REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
14
1006
RSP HUMERAL SOCKET INSERT
2
Cleared 510(K)
K
13
3378
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
14
0904
RSP MONOBLOCK STEM WITH P2 COATING, SIZE 6
2
Cleared 510(K)
K
13
0550
RSP MODULAR GLENOID BASEPLATE, GLENOID TAPER ADAPTER, RETAINING SCREW
2
Cleared 510(K)
K
13
0895
REUNION RSA SHOULDER SYSTEM
2
Cleared 510(K)
K
13
2285
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
13
1231
AEQUALIS SHOULDER FRACTURE SYSTEM, AEQUALIS REVERSED SHOULDER PROSTHESIS, AEQUALIS REVERSED FRACTURE SHOULDER PROTHESIS
2
Cleared 510(K)
K
13
0390
COMPREHENSIVE CONVERTIBLE GLENOID
2
Cleared 510(K)
K
13
1353
COMPREHENSIVE REVERSE SHOULDER - TITANIUM GLENOSPHERE
2
Cleared 510(K)
K
13
2239
COMPREHENSIVE REVERSE SHOULDER SCREWS
2
Cleared 510(K)
K
13
1575
EXACTECH EQUINOX SUPERIOR/POSTERIOR AUGMENT REVERSE SHOULDER GLENOID BASEPLATE - LEFT & RIGHT
2
Cleared 510(K)
K
13
0661
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
12
1067
EXACTECH EQUINOXE SHOULDER SYSTEM TORQUE DEFINING SCREW AND SHORT REPLICATOR PLATE
2
Cleared 510(K)
K
12
2692
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM, NON-POROUS HUMERAL STEMS
2
Cleared 510(K)
K
12
2442
DEPUY CTA REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
12
1183
COMPREHENSIVE REVERSE SHOULDER - E1 POLYETHYLENE CLAIMS
2
Cleared 510(K)
K
11
2193
ARROW REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
12
0374
SEVIIN REVERSE SHOULDER
2
Cleared 510(K)
K
12
0739
AEQUALIS ADJUSTABLE MODULAR REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
12
0174
DEPUT DELTA XTEND REVERSE SHOULDER
2
Cleared 510(K)
K
11
2144
AEQUALIS SHOULDER FRACTURE SYSTEM, AEQUALIS REVERSED SHOULDER PROSTHESIS, AEQUALIS REVERSED FRACTURE SHOULDER PROSTHESIS
2
Cleared 510(K)
K
11
3254
SMR MODULAR GLENOID-METAL-BACK SMR MODULAR GLENOID-LINER SMR MODULAR GLENOID-BONE SCREWS
2
Cleared 510(K)
K
12
0121
COMPREHENSIVE REVERSE SHOULDER-MINI BASEPLATE
2
Cleared 510(K)
K
11
3069
COMPREHENSIVE REVERSE SHOULDER HUMERAL TRAY
2
Cleared 510(K)
K
11
3523
LIMACORPORATE SMR REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
11
3121
COMPREHENSIVE REVERSE SHOULDER
2
Cleared 510(K)
K
11
2069
RSP GLENOID BASEPLATE POROUS COATED
2
Cleared 510(K)
K
10
3251
DUOCENTRIC REVERSED
2
Cleared 510(K)
K
11
2615
AEQUALIS ASCEND MODULAR REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
11
1735
REVERSE SHOULDER PROSTHESIS MONOBLOCK HEMI ADAPTER
2
Cleared 510(K)
K
11
1629
TURON RSP SOCKET SHELL-NEUTRAL MODEL 508-02-000, TURON RSP SOCKET SHELL-OFFSET MODEL 508-02-001
2
Cleared 510(K)
K
11
0598
SMR REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
11
1061
REVERSE SHOULDER MONOBLOCK PROSTHESIS (RSP)
2
Cleared 510(K)
K
11
0599
AEQUALIS ASCEND MODULAR REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
11
0708
EQUINOXE REVERSE SHOULDER COMPRESSION SCREW / 38MM AND 42MM GLENOSPHERE / SUPERIOR AUGMENT GLENOID PLATE, 10 DEGREES...
2
Cleared 510(K)
K
10
3208
REVERSE SHOULDER PROSTHESIS MONOBLOCK STEM
2
Cleared 510(K)
K
10
1996
DEPUY GLOBAL UNITE SHOULDER SYSTEM
2
Cleared 510(K)
K
10
2951
EXACTECH EQUINOX FIXED ANGLE REPLICATOR PLATE (0MM,1.5MM,4.5MM), HUMERAL HEAD-SHORT (44MM,47MM), GLENOSPHERE (38MM,42MM)
2
Cleared 510(K)
K
09
3803
BIO-MODULAR REVERSE SHOLDER
2
Cleared 510(K)
K
10
1909
EXACTECH EQUINOXE, PLATFORM FRACTURE STEM
2
Cleared 510(K)
K
10
0741
REVERSE SHOULDER PROSTHESIS MONOBLOCK STEM, REVERSE SHOULDER PROSTHESIS HUMERAL INSERTS, MODEL 510-00-006/012
2
Cleared 510(K)
K
09
3275
EXACTECH EQUINOXE REVERSE SHOULDER SYSTEM 36MM GLENOSPHERE AND HUMERAL LINER
2
Cleared 510(K)
K
10
0142
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
09
2900
EXACTECH EQUINOXE PLATFORM FRACTURE STEM AND REVISION PLATFORM FRACTURE STEM
2
Cleared 510(K)
K
09
2873
REVERSE SHOULDER PROSTHESIS
2
Cleared 510(K)
K
08
2702
EXACTECH EQUINOXE REVERSE SHOULDER SYSTEM+15MM HUMERAL ADAPTER TRAY
2
Cleared 510(K)
K
08
1016
SMITH & NEPHEW, INC., PROMOS REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
08
1059
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
08
0642
COMPREHENSIVE REVERSE SHOULDER
2
Cleared 510(K)
K
07
3688
EQUINOXE REVERSE SHOULDER SYSTEM FRACTURE HUMERAL ADAPTER TRAY AND LOCKING SCREW
2
Cleared 510(K)
K
07
3676
DEPUY DELTA XTEND REVERSE SHOULDER HIGH MOBILITY CUP
2
Cleared 510(K)
K
07
2804
COMPREHENSIVE RS SHOULDER SYSTEM
2
Cleared 510(K)
K
07
1948
AEQUALIS REVERSED ADAPTER
2
Cleared 510(K)
K
07
1379
DELTA XTEND REVERSE SHOULDER MODULAR STEM
2
Cleared 510(K)
K
06
3569
EQUINOXE REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
06
2250
DELTA XTEND REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
06
2116
DELTA CTA REVERSE SHOULDER SYSTEM HUMERAL HEADS
2
Cleared 510(K)
K
06
1439
AEQUALIS REVERSED PROSTHESIS
2
Cleared 510(K)
K
06
0704
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM, SIZES 8MM AND 10MM
2
Cleared 510(K)
K
05
3274
ANATOMICAL SHOULDER INVERSE/REVERSE
2
Cleared 510(K)
K
05
2906
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM
2
Cleared 510(K)
K
05
2086
ENCORE REVERSE SHOULDER PROSTHESIS HUMERAL STEM ADAPTER
2
Cleared 510(K)
K
05
1075
ENCORE REVERSE SHOULDER PROSTHESIS
2
Cleared 510(K)
K
05
0315
DELTA HUMERAL CUPS
2
Cleared 510(K)
K
04
1066
ENCORE REVERSE SHOULDER PROSTHESIS
2
Cleared 510(K)
K
05
0316
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
04
1873
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
03
0941
AEQUALIS REVERSED SHOULDER PROSTHESIS
2
Cleared 510(K)
K
02
1478
DELTA SHOULDER
2
Cleared 510(K)
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
2
Product Code
PLF
Bone Wedge
2
Product Code
PLR
Spinal Vertebral Body Replacement Device - Cervical
2
Product Code
PLW
Acetabular Cup Orientation System
2
Product Code
PML
Bone Cement, Posterior Screw Augmentation
2
Product Code
PPQ
Transtibial Anterior Cruciate Ligament Kit
2
Product Code
QHQ
Total Shoulder Arthroplasty System
2
Product Code
PQC
Pedicle Screw Placement Guide
2
Product Code
QAC
Screw Sleeve Bone Fixation Device
2
Product Code
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
2
Product Code
QFP
Intraoperative Orthopedic Strain Sensor
2
Product Code
QHE
Shoulder Arthroplasty Implantation System
2
Product Code
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
2
Product Code
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
2
Product Code
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
2
Product Code
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
2
Product Code
JDK
Prosthesis, Hip, Cement Restrictor
2
Product Code
LZN
Cement Obturator
2
Product Code
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
2
Product Code
QSD
Posterior Cervical Screw Placement Guide
2
Product Code
QSR
Sacroiliac Screw Placement Guide
2
Product Code
QVI
Screw Sleeve Bone Fixation Device, Spine
2
Product Code
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
SAI
Ankle Fusion Cage
2
Product Code
SCY
Sacroiliac Joint Guidewire Placement Device
2
Product Code
Subpart E—Neurological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
OR
/
subpart-d—prosthetic-devices
/
PHX
/
K242253
View Source
JARVIS Glenoid Reverse Shoulder Prosthesis
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K242253
510(k) Type
Traditional
Applicant
FH Industrie
Country
France
FDA Decision
Substantially Equivalent
Decision Date
11/25/2024
Days to Decision
117 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Miscellaneous
Subpart B—Diagnostic Devices
Subpart D—Prosthetic Devices
NDH
Nail, Fixation, Bone, Metallic
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
HSA
Prosthesis, Knee, Hemi-, Femoral
HSB
Rod, Fixation, Intramedullary And Accessories
NDI
Staple, Fixation, Bone, Metallic
HRS
Plate, Fixation, Bone
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
HTN
Washer, Bolt Nut
HTY
Pin, Fixation, Smooth
HWC
Screw, Fixation, Bone
HXA
Prosthesis, Tendon, Passive
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
JDC
Prosthesis, Elbow, Constrained, Cemented
JDD
Prosthesis, Upper Femoral
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
JDN
Implant, Fixation Device, Spinal
JDO
Device, Fixation, Proximal Femoral, Implant
JDP
Condylar Plate Fixation Implant
JDQ
Cerclage, Fixation
JDR
Staple, Fixation, Bone
JDS
Nail, Fixation, Bone
JDT
Cap, Bone
JDW
Pin, Fixation, Threaded
JEC
Component, Traction, Invasive
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
KIG
Prosthesis, Wrist, Constrained, Polymer
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
KWD
Prosthesis, Toe, Hemi-, Phalangeal
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
KWF
Prosthesis, Finger, Polymer
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
KWH
Prosthesis, Toe, Constrained, Polymer
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
KWM
Prosthesis, Wrist, Semi-Constrained
KWN
Prosthesis, Wrist, Carpal Lunate
KWO
Prosthesis, Wrist, Carpal Scaphoid
KWP
Appliance, Fixation, Spinal Interlaminal
KWQ
Appliance, Fixation, Spinal Intervertebral Body
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
KXA
Prosthesis, Hip, Femoral, Resurfacing
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
KXD
Prosthesis, Hip, Constrained, Metal
KXE
Prosthesis, Wrist, Hemi-, Ulnar
KYI
Prosthesis, Wrist, Carpal Trapezium
KYJ
Prosthesis, Finger, Constrained, Polymer
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
KYN
Prosthesis, Wrist, Constrained, Metal
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
LOD
Bone Cement
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
LRN
Wire, Surgical
LTO
Spacer, Cement
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
LYP
Accessories, Fixation, Spinal Interlaminal
LYT
Fixation Accessory
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
MBB
Bone Cement, Antibiotic
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
MJW
Prosthesis, Subtalar, Plug, Polymer
MNH
Orthosis, Spondylolisthesis Spinal Fixation
MNI
Orthosis, Spinal Pedicle Fixation
MNU
Staple, Absorbable
MQP
Spinal Vertebral Body Replacement Device
MQV
Filler, Bone Void, Calcium Compound
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
NDD
Cerclage, Fixation, Metallic
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
NDK
System, External Fixator (With Metallic Invasive Components)
NDL
Pin, Fixation, Smooth, Metallic
NDM
Pin, Fixation, Threaded, Metallic
NDN
Cement, Bone, Vertebroplasty
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
NKB
Thoracolumbosacral Pedicle Screw System
NKG
Posterior Cervical Screw System
NOV
Anchor, Suture, Bone Fixation, Metallic
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
NQP
Posterior Metal/Polymer Spinal System, Fusion
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
NUD
Vertebroplasty Compound, Calcium Based
NVC
Bone, Heterograft
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
OOG
Knee Arthroplasty Implantation System
OOL
Electronic Depth Gauge
OQB
Intervertebral Body Graft Containment Device
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
OSN
Software For Diagnosis/Treatment
OUR
Sacroiliac Joint Fixation
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
OVZ
Pin, Fixation, Resorbable, Hard Tissue
OWI
Bone Fixation Cerclage, Sublaminar
OYK
Ankle Arthroplasty Implantation System
OZI
Internal Hinged Elbow Fixator
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
PBF
Orthopaedic Surgical Planning And Instrument Guides
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
PEK
Spinous Process Plate
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
PHQ
Anterior Staple As Supplemental Fixation For Fusion
PHX
Shoulder Prosthesis, Reverse Configuration
K
25
2567
AltiVate Reverse® ADLC Glenosphere
K
25
2516
N22 EZ Glenosphere
K
25
4003
JARVIS Metaphyseal Stem
K
25
2788
Tornier Perform™ Reversed Monopost Glenoid (Perform Mono)
K
25
0338
MSS - Humeral reverse liners extension
K
25
3345
JARVIS Diaphyseal Stem Standard
K
25
2411
JARVIS Glenoid Reverse Shoulder Prosthesis
K
25
2141
AltiVate Reverse® Glenoid
K
24
3448
Equinoxe® Shoulder System
K
24
3826
SMR Reverse HP Shoulder System
K
24
3643
restor3d Reverse Total Shoulder Arthroplasty System
K
25
1184
AltiVate Reverse Shoulder System; RSP Shoulder System; SMR Shoulder System; PRIMA Humeral System; PRIMA Glenoid System
K
24
2253
JARVIS Glenoid Reverse Shoulder Prosthesis
K
24
1491
Blueprint Patient-Specific Instrumentation; Shoulder iD Primary Reversed Glenoid
K
23
3482
Equinoxe® Central Screw Baseplate System
K
23
3481
AltiVate Reverse® Glenoid
K
24
1043
Augment Off-Axis Instrument System
K
24
0278
Full Wedge Lateralized and Augmented Baseplates
K
23
4105
Catalyst F1x Shoulder System
K
23
3148
Augment Off-Axis Instrument System
K
23
2265
BLUEPRINT™ Patient Specific Instrumentation
K
23
1445
LINK Embrace Shoulder System - Reverse Configuration
K
23
1911
Glenoid Reconstruction System – Full Wedge Baseplate
K
23
2583
Catalyst R1 Reverse Shoulder System
K
22
3833
Exactech® Equinoxe® Reverse Humeral Liners and Humeral Adapter Trays
K
23
2226
ARROW Off-Centred Humeral Insert
K
22
3801
FX V135(TM) Shoulder Prosthesis
K
22
3655
Catalyst R1 Reverse Shoulder System
K
23
0366
Arthrex Univers Revers Monoblock Stem Size 4/33
K
21
4001
Comprehensive® Shoulder System, Comprehensive® Reverse Shoulder System
K
22
3211
INHANCETM Shoulder System – Humeral Stems and Stemless
K
21
3459
Glenoid Reconstruction System
K
22
2936
Humeris® 135 Shoulder System
K
22
0914
Tornier Perform Humeral System – Fracture
K
22
1467
INHANCETM Reverse Glenoid Peripheral Posts
K
21
3349
Catalyst R1 Reverse Shoulder System
K
21
3117
FX V135 Shoulder Prosthesis
K
21
2737
INHANCE™ Reverse Shoulder System
K
21
2800
PRIMA Humeral System and SMR Glenosphere Ø42
K
20
2024
ARROW Short Stem Humeral System
K
21
2992
LINK® Embrace Shoulder System - Reverse Configuration
K
21
2415
Arthrex Modular Glenoid System-Titanium Glenosphere
K
21
1359
Tornier Perform™ Patient-Matched Primary Reversed Glenoid and BLUEPRINT™ Patient Specific Instrumentation
K
21
1729
Comprehensive® Convertible Glenoid - Vivacit-E Liner
K
21
3124
Tomier Perform™ Reversed Glenoid Cannulated Glenospheres
K
21
2710
GLOBAL UNITE™ Platform Shoulder System
K
21
1074
Univers Revers Modular Glenoid System, Standard Augment Baseplates
K
21
0790
Lateralized and Augmented Baseplates
K
21
0533
Inset Reverse Total Shoulder System
K
21
1553
Tecomet Global Unite Short Stem Instrumentation
K
21
1991
Catalyst R1 Reverse Shoulder System
K
20
3694
DELTA XTEND Reverse Shoulder System
K
21
0717
Bone Screws dia. 5,0 mm
K
20
3375
OVOMotion Reverse Shoulder Arthroplasty System
K
21
0207
Humeral Eccentric Reverse Metaphysis
K
20
3755
Shoulder System - TiNbN Coating
K
21
0167
DELTA XTEND Reverse Shoulder System
K
20
2232
Comprehensive Vault Reconstruction System
K
20
2611
Catalyst OrthoScience R1 Reverse Shoulder System
K
20
0368
LINK Embrace Shoulder System - Reverse Configuration
K
20
2098
GLOBAL UNITE™ Platform Shoulder System
K
20
0171
SMR TT Augmented Glenoid System
K
20
0895
Univers Revers Modular Glenoid System, Half Augment Baseplate
K
19
3175
Lateralized Glenosphere
K
19
1146
Humelock TiN Coated Glenosphere
K
19
3394
Humeral Cup Stability & Humeral Cup 135/145o Stability
K
19
3373
Comprehensive® Reverse Shoulder
K
19
2967
Medacta Shoulder System
K
19
2855
DELTA XTEND(TM) Reverse Shoulder System
K
19
2799
Glenoid Baseplate with Screw
K
19
3098
Exactech® Equinoxe® Reverse Shoulder Glenospheres
K
19
3099
Anatomical Shoulder System
K
19
3372
Univers Revers Modular Glenoid System (Augemented baseplates)
K
19
1960
Arthrex Univers Revers Modular Glenoid System
K
19
0738
MyShoulder Placement Guides
K
19
0588
Integra TITAN Reverse Shoulder System
K
19
1746
SMR TT Augmented Glenoid System
K
19
2206
32mm Glenosphere and Humeral Cup
K
19
2448
Delta Xtend Revers Shoulder System
K
19
1561
Exactech Equinoxe Humeral Augmented Trays
K
18
3077
Delta Xtend Reverse Shoulder System
K
18
3696
Aequalis PerFORM Reversed Glenoid, Aequalis PerFORM + Reversed Glenoid
K
18
1826
Glenoid Polyaxial Non-locking Screws
K
18
2536
Exactech Equinoxe Small Reverse Shoulder Glenospheres , Exactech Equinoxe Reverse Shoulder Humeral Liners , Exactech Equinoxe Small Reverse Shoulder Glenoid Plates , Exactech Equinoxe Reverse Shoulder Locking Cap
K
18
1999
Integra TITAN Reverse Shoulder System
K
18
2039
Arthrex Univers Revers Porous Coated Baseplate and Universal Glenoid Inlay
K
18
1611
Comprehensive Reverse Shoulder System
K
18
0632
Exactech Equinoxe Small Reverse Shoulder System
K
17
3717
Integra TITAN Reverse Shoulder System
K
17
3900
Arthrex Univers Revers Modular Glenoid System
K
18
0089
Medacta Shoulder System Short Humeral Diaphysis
K
17
2371
Arthrex UNIVERS REVERS COATED BASEPLATE
K
17
3411
Comprehensive Segmental Revision System (SRS)
K
17
1789
ARROW Reverse Porous Glenoid
K
17
0748
GLOBAL UNITE Platform Shoulder System
K
17
2502
Comprehensive Augmented Glenoid Components, Comprehensive Standard Baseplate, Comprehensive Mini Baseplate
K
17
3073
AltiVate Anatomic to Reverse Conversion Module
K
17
0414
Arthrex Univers Revers Apex Humeral Stems
K
17
1058
Medacta Shoulder System: Threaded Glenoid Baseplate
K
17
2767
Zimmer Trabecular Metal Reverse Shoulder System, Mini Glenoid
K
17
0452
Medacta Shoulder System
K
17
0711
ASHCOM Shoulder System, Anatomical Shoulder System and Anatomical Shoulder Combined System
K
16
3669
Humeris Shoulder
K
16
2325
Exactech Equinoxe Reverse Shoulder Locking Cap, Exactech Equinoxe Reverse Shoulder Compression Screws, Exactech Equinoxe Reverse Shoulder Glenosphere Locking Screw
K
16
1120
SMR TT Metal Back Glenoid, Bone Graft instruments
K
16
2726
Exactech® Equinoxe® Preserve Stem
K
16
2455
Humelock Reversed Shoulder
K
16
1742
Aequalis PerFORM Reversed, Aequalis PerFORM+ Reversed Glenoid
K
16
1189
Integra TITAN Reverse Shoulder System
K
15
2754
COMPREHENSIVE VAULT RECONSTRUCTION SYSTEM (VRS)
K
15
2966
Aequalis Fx2
K
15
0488
Humelock II Reversible Shoulder System
K
15
0568
ARROW Humeral stems size 6 and 16
K
15
0458
Exactech Equinoxe Reverse Shoulder 46x21mm Glenosphere
K
14
2778
ARROW Reverse Shoulder long keel and short keel glenoid base
K
14
2863
Univers Rivers Shoulder Prosthesis System
K
14
1345
AEQUALIS FX2
K
14
2139
SMR 40MM GLENOSPHERE
K
14
1990
ENCORE HUMERAL SHOULDER STEM
K
14
0478
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
14
0082
AEQUALIS(TM) ASCENT(TM) FLEX SHOULDER SYSTEM
K
14
0652
POROUS COATED COMPREHENSIVE FRACTURE STEMS
K
14
1029
TORNIER AEQUALIS ADJUSTABLE REVERSE SHOULDER SYSTEM
K
14
1006
RSP HUMERAL SOCKET INSERT
K
13
3378
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM
K
14
0904
RSP MONOBLOCK STEM WITH P2 COATING, SIZE 6
K
13
0550
RSP MODULAR GLENOID BASEPLATE, GLENOID TAPER ADAPTER, RETAINING SCREW
K
13
0895
REUNION RSA SHOULDER SYSTEM
K
13
2285
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
13
1231
AEQUALIS SHOULDER FRACTURE SYSTEM, AEQUALIS REVERSED SHOULDER PROSTHESIS, AEQUALIS REVERSED FRACTURE SHOULDER PROTHESIS
K
13
0390
COMPREHENSIVE CONVERTIBLE GLENOID
K
13
1353
COMPREHENSIVE REVERSE SHOULDER - TITANIUM GLENOSPHERE
K
13
2239
COMPREHENSIVE REVERSE SHOULDER SCREWS
K
13
1575
EXACTECH EQUINOX SUPERIOR/POSTERIOR AUGMENT REVERSE SHOULDER GLENOID BASEPLATE - LEFT & RIGHT
K
13
0661
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM
K
12
1067
EXACTECH EQUINOXE SHOULDER SYSTEM TORQUE DEFINING SCREW AND SHORT REPLICATOR PLATE
K
12
2692
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM, NON-POROUS HUMERAL STEMS
K
12
2442
DEPUY CTA REVERSE SHOULDER SYSTEM
K
12
1183
COMPREHENSIVE REVERSE SHOULDER - E1 POLYETHYLENE CLAIMS
K
11
2193
ARROW REVERSE SHOULDER SYSTEM
K
12
0374
SEVIIN REVERSE SHOULDER
K
12
0739
AEQUALIS ADJUSTABLE MODULAR REVERSE SHOULDER SYSTEM
K
12
0174
DEPUT DELTA XTEND REVERSE SHOULDER
K
11
2144
AEQUALIS SHOULDER FRACTURE SYSTEM, AEQUALIS REVERSED SHOULDER PROSTHESIS, AEQUALIS REVERSED FRACTURE SHOULDER PROSTHESIS
K
11
3254
SMR MODULAR GLENOID-METAL-BACK SMR MODULAR GLENOID-LINER SMR MODULAR GLENOID-BONE SCREWS
K
12
0121
COMPREHENSIVE REVERSE SHOULDER-MINI BASEPLATE
K
11
3069
COMPREHENSIVE REVERSE SHOULDER HUMERAL TRAY
K
11
3523
LIMACORPORATE SMR REVERSE SHOULDER SYSTEM
K
11
3121
COMPREHENSIVE REVERSE SHOULDER
K
11
2069
RSP GLENOID BASEPLATE POROUS COATED
K
10
3251
DUOCENTRIC REVERSED
K
11
2615
AEQUALIS ASCEND MODULAR REVERSE SHOULDER SYSTEM
K
11
1735
REVERSE SHOULDER PROSTHESIS MONOBLOCK HEMI ADAPTER
K
11
1629
TURON RSP SOCKET SHELL-NEUTRAL MODEL 508-02-000, TURON RSP SOCKET SHELL-OFFSET MODEL 508-02-001
K
11
0598
SMR REVERSE SHOULDER SYSTEM
K
11
1061
REVERSE SHOULDER MONOBLOCK PROSTHESIS (RSP)
K
11
0599
AEQUALIS ASCEND MODULAR REVERSE SHOULDER SYSTEM
K
11
0708
EQUINOXE REVERSE SHOULDER COMPRESSION SCREW / 38MM AND 42MM GLENOSPHERE / SUPERIOR AUGMENT GLENOID PLATE, 10 DEGREES...
K
10
3208
REVERSE SHOULDER PROSTHESIS MONOBLOCK STEM
K
10
1996
DEPUY GLOBAL UNITE SHOULDER SYSTEM
K
10
2951
EXACTECH EQUINOX FIXED ANGLE REPLICATOR PLATE (0MM,1.5MM,4.5MM), HUMERAL HEAD-SHORT (44MM,47MM), GLENOSPHERE (38MM,42MM)
K
09
3803
BIO-MODULAR REVERSE SHOLDER
K
10
1909
EXACTECH EQUINOXE, PLATFORM FRACTURE STEM
K
10
0741
REVERSE SHOULDER PROSTHESIS MONOBLOCK STEM, REVERSE SHOULDER PROSTHESIS HUMERAL INSERTS, MODEL 510-00-006/012
K
09
3275
EXACTECH EQUINOXE REVERSE SHOULDER SYSTEM 36MM GLENOSPHERE AND HUMERAL LINER
K
10
0142
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
09
2900
EXACTECH EQUINOXE PLATFORM FRACTURE STEM AND REVISION PLATFORM FRACTURE STEM
K
09
2873
REVERSE SHOULDER PROSTHESIS
K
08
2702
EXACTECH EQUINOXE REVERSE SHOULDER SYSTEM+15MM HUMERAL ADAPTER TRAY
K
08
1016
SMITH & NEPHEW, INC., PROMOS REVERSE SHOULDER SYSTEM
K
08
1059
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
08
0642
COMPREHENSIVE REVERSE SHOULDER
K
07
3688
EQUINOXE REVERSE SHOULDER SYSTEM FRACTURE HUMERAL ADAPTER TRAY AND LOCKING SCREW
K
07
3676
DEPUY DELTA XTEND REVERSE SHOULDER HIGH MOBILITY CUP
K
07
2804
COMPREHENSIVE RS SHOULDER SYSTEM
K
07
1948
AEQUALIS REVERSED ADAPTER
K
07
1379
DELTA XTEND REVERSE SHOULDER MODULAR STEM
K
06
3569
EQUINOXE REVERSE SHOULDER SYSTEM
K
06
2250
DELTA XTEND REVERSE SHOULDER SYSTEM
K
06
2116
DELTA CTA REVERSE SHOULDER SYSTEM HUMERAL HEADS
K
06
1439
AEQUALIS REVERSED PROSTHESIS
K
06
0704
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM, SIZES 8MM AND 10MM
K
05
3274
ANATOMICAL SHOULDER INVERSE/REVERSE
K
05
2906
ZIMMER TRABECULAR METAL REVERSE SHOULDER SYSTEM
K
05
2086
ENCORE REVERSE SHOULDER PROSTHESIS HUMERAL STEM ADAPTER
K
05
1075
ENCORE REVERSE SHOULDER PROSTHESIS
K
05
0315
DELTA HUMERAL CUPS
K
04
1066
ENCORE REVERSE SHOULDER PROSTHESIS
K
05
0316
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
04
1873
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
03
0941
AEQUALIS REVERSED SHOULDER PROSTHESIS
K
02
1478
DELTA SHOULDER
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
PLF
Bone Wedge
PLR
Spinal Vertebral Body Replacement Device - Cervical
PLW
Acetabular Cup Orientation System
PML
Bone Cement, Posterior Screw Augmentation
PPQ
Transtibial Anterior Cruciate Ligament Kit
QHQ
Total Shoulder Arthroplasty System
PQC
Pedicle Screw Placement Guide
QAC
Screw Sleeve Bone Fixation Device
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
QFP
Intraoperative Orthopedic Strain Sensor
QHE
Shoulder Arthroplasty Implantation System
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
JDK
Prosthesis, Hip, Cement Restrictor
LZN
Cement Obturator
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
QSD
Posterior Cervical Screw Placement Guide
QSR
Sacroiliac Screw Placement Guide
QVI
Screw Sleeve Bone Fixation Device, Spine
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
SAI
Ankle Fusion Cage
SCY
Sacroiliac Joint Guidewire Placement Device
Subpart E—Neurological Surgical Devices
Subpart E—Surgical Devices
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OR
/
subpart-d—prosthetic-devices
/
PHX
/
K242253
View Source
JARVIS Glenoid Reverse Shoulder Prosthesis
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K242253
510(k) Type
Traditional
Applicant
FH Industrie
Country
France
FDA Decision
Substantially Equivalent
Decision Date
11/25/2024
Days to Decision
117 days
Submission Type
Summary