FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
NDH
Nail, Fixation, Bone, Metallic
2
Product Code
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
3
Product Code
HSA
Prosthesis, Knee, Hemi-, Femoral
3
Product Code
HSB
Rod, Fixation, Intramedullary And Accessories
2
Product Code
NDI
Staple, Fixation, Bone, Metallic
2
Product Code
HRS
Plate, Fixation, Bone
2
Product Code
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
2
Product Code
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
2
Product Code
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
2
Product Code
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
2
Product Code
HTN
Washer, Bolt Nut
2
Product Code
HTY
Pin, Fixation, Smooth
2
Product Code
HWC
Screw, Fixation, Bone
2
Product Code
HXA
Prosthesis, Tendon, Passive
2
Product Code
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
2
Product Code
JDC
Prosthesis, Elbow, Constrained, Cemented
2
Product Code
JDD
Prosthesis, Upper Femoral
2
Product Code
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
2
Product Code
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
3
Product Code
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
2
Product Code
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
3
Product Code
JDN
Implant, Fixation Device, Spinal
2
Product Code
JDO
Device, Fixation, Proximal Femoral, Implant
2
Product Code
JDP
Condylar Plate Fixation Implant
2
Product Code
JDQ
Cerclage, Fixation
2
Product Code
JDR
Staple, Fixation, Bone
2
Product Code
JDS
Nail, Fixation, Bone
2
Product Code
JDT
Cap, Bone
1
Product Code
JDW
Pin, Fixation, Threaded
2
Product Code
JEC
Component, Traction, Invasive
2
Product Code
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
2
Product Code
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
2
Product Code
KIG
Prosthesis, Wrist, Constrained, Polymer
2
Product Code
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
2
Product Code
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
2
Product Code
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
3
Product Code
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
2
Product Code
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
3
Product Code
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
2
Product Code
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
3
Product Code
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
2
Product Code
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
2
Product Code
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
2
Product Code
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
3
Product Code
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
3
Product Code
KWD
Prosthesis, Toe, Hemi-, Phalangeal
2
Product Code
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
3
Product Code
KWF
Prosthesis, Finger, Polymer
2
Product Code
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
3
Product Code
KWH
Prosthesis, Toe, Constrained, Polymer
2
Product Code
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
2
Product Code
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
3
Product Code
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
2
Product Code
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
2
Product Code
KWM
Prosthesis, Wrist, Semi-Constrained
2
Product Code
KWN
Prosthesis, Wrist, Carpal Lunate
2
Product Code
KWO
Prosthesis, Wrist, Carpal Scaphoid
2
Product Code
KWP
Appliance, Fixation, Spinal Interlaminal
2
Product Code
KWQ
Appliance, Fixation, Spinal Intervertebral Body
2
Product Code
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
3
Product Code
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
2
Product Code
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
2
Product Code
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
2
Product Code
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
2
Product Code
KXA
Prosthesis, Hip, Femoral, Resurfacing
2
Product Code
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
3
Product Code
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
3
Product Code
KXD
Prosthesis, Hip, Constrained, Metal
3
Product Code
KXE
Prosthesis, Wrist, Hemi-, Ulnar
2
Product Code
KYI
Prosthesis, Wrist, Carpal Trapezium
2
Product Code
KYJ
Prosthesis, Finger, Constrained, Polymer
2
Product Code
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
2
Product Code
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
3
Product Code
KYN
Prosthesis, Wrist, Constrained, Metal
3
Product Code
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
3
Product Code
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
2
Product Code
LOD
Bone Cement
2
Product Code
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
2
Product Code
LRN
Wire, Surgical
2
Product Code
LTO
Spacer, Cement
3
Product Code
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
2
Product Code
LYP
Accessories, Fixation, Spinal Interlaminal
2
Product Code
LYT
Fixation Accessory
2
Product Code
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
2
Product Code
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
2
Product Code
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
2
Product Code
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
2
Product Code
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
2
Product Code
MBB
Bone Cement, Antibiotic
2
Product Code
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
2
Product Code
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
2
Product Code
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
2
Product Code
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
2
Product Code
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
2
Product Code
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
2
Product Code
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
2
Product Code
MJW
Prosthesis, Subtalar, Plug, Polymer
2
Product Code
MNH
Orthosis, Spondylolisthesis Spinal Fixation
2
Product Code
K
16
2066
Reliance Spinal Screw System
2
Cleared 510(K)
K
16
2801
CastleLoc Spinal Fixation System
2
Cleared 510(K)
K
16
2143
FixxSure® X-Link
2
Cleared 510(K)
K
16
1151
Spinal fixation system
2
Cleared 510(K)
K
16
2189
ANAX™ 5.5 Spinal System
2
Cleared 510(K)
K
15
1362
HC Spinal System
2
Cleared 510(K)
K
15
3404
Zavation Spinal System
2
Cleared 510(K)
K
16
0020
Captiva Spine and CapLOX II/TowerLOX Pedicle Screw System
2
Cleared 510(K)
K
14
3013
Spinal Inner Fixation System
2
Cleared 510(K)
K
15
1695
Romeo posterior osteosynthesis system
2
Cleared 510(K)
K
15
1116
CapLOX II/TowerLOX Pedicle Screw System
2
Cleared 510(K)
K
15
0283
Republic Spine Dark Star Spinal System
2
Cleared 510(K)
K
14
2798
PASS LP Spinal System
2
Cleared 510(K)
K
14
3417
ANAX 5.5 Spinal System
2
Cleared 510(K)
K
14
3377
PedFuse Pedicle Screw System
2
Cleared 510(K)
K
14
2957
Ideal pedicle screw spinal system
2
Cleared 510(K)
K
14
2655
CB PROT II Posterior Spinal System
2
Cleared 510(K)
K
14
0359
MAXIMIS SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
14
2290
KangLi pedical screw spinal system
2
Cleared 510(K)
K
13
4011
GENERAL SPINAL SYSTEM
2
Cleared 510(K)
K
13
3575
SPINEVISION LUMIS CANNULATED PEDICLE SCREW FIXATION SYSTEM, SPINEVISION U.L.I.S. PEDICLE SCREW FIXATION SYSTEM
2
Cleared 510(K)
K
14
1376
INERTIA PEDICLE SCREW SYSTEM, HONOUR SPACER SYSTEM, FACET FIXX, STRUXXURE ANTERIOR CERVICAL PLATE AND SCREWS
2
Cleared 510(K)
K
14
0053
KANGLI PEDICLE SCREW SPINAL SYSTEM
2
Cleared 510(K)
K
14
0678
COSMOLOCK PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
14
0787
PLS (POSTERIOR LUMBAR SYSTEM)
2
Cleared 510(K)
K
14
0948
ROMEO POSTERIOR OSTEOSYNTHESIS SYSTEM
2
Cleared 510(K)
K
13
3153
SPINEFRONTIER PEDFUSE PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
13
3690
TRUE SPINAL FUSSION SYSTEM
2
Cleared 510(K)
K
13
3287
PRESSON SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
13
2403
ANNEXTM ADJACENT LEVEL SYSTEM
2
Cleared 510(K)
K
13
2218
PERFIX ILIAC SCREW SYSTEM
2
Cleared 510(K)
K
13
2101
ANAX 5.5 SPINAL SYSTEM
2
Cleared 510(K)
K
13
1810
OSSEUS BLACK DIAMOND PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
13
1538
CAPLOX II PEDICLE SCREW SYSTEM/TOWERLOX PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
13
0267
ROMEO POSTERIOR OSTEOSYNTHESIS SYSTEM
2
Cleared 510(K)
K
12
2994
INTRAMEDULLARY NAIL SYSTEM
2
Cleared 510(K)
K
12
3487
GSO GS1 CANNULATED SCREW SYSTEM
2
Cleared 510(K)
K
12
3164
SPINEFRONTIER PEDFUSE PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
12
3476
MEGA 5.5 SPINE SYSTEM
2
Cleared 510(K)
K
12
2592
INSTINCT JAVA SYSTEM
2
Cleared 510(K)
K
12
2814
GALLEON PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
12
0832
FORTEX PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
12
1016
RANGE SPINAL SYSTEM (MESA AND DENALI)
2
Cleared 510(K)
K
12
0760
LDR SPINE SPINETUNE TL SPINAL SYSTEM
2
Cleared 510(K)
K
11
1940
S 100 PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
12
0491
DSS STABILIZATION SYSTEM-RIGID
2
Cleared 510(K)
K
12
0353
SYNSTER PEDICLE SCREW SYSTEM SYNSTER PLUS PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
10
3573
ARTS2 SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
11
0633
LANCER PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
11
1995
XINGTM SPINE SYSTEM
2
Cleared 510(K)
K
11
1690
DEVINE SPINAL SYSTEM
2
Cleared 510(K)
K
11
0497
PASS LP SPINAL SYSTEM
2
Cleared 510(K)
K
11
1370
ODALYS PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
11
1362
REXIOUS SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
2458
4CIS SOLAR SPINE SYSTEM AND 4CIS APOLLON SPINE SYSTEM
2
Cleared 510(K)
K
11
0321
TIGER SPINE SYSTEM
2
Cleared 510(K)
K
10
1374
AAXTER A3 POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
10
2574
PALLA M SPINAL SYSTEM
2
Cleared 510(K)
K
10
2636
ZENITH PEDICLE SYSTEM
2
Cleared 510(K)
K
10
1818
4CIS VANE SPINE SYSTEM
2
Cleared 510(K)
K
10
3085
VENUS BASIC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
2853
FLAMENCO SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
2870
EXACTECH PROLIANT POLYAXIAL PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
10
1446
EMERALD SPINAL SYSTEM
2
Cleared 510(K)
K
10
1278
INERTIA PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
10
2488
APEX SPINE SYSTEM W/ COCR RODS
2
Cleared 510(K)
K
09
3771
QUANTUM/STREAMLINE TL MIS SPINAL SYSTEM
2
Cleared 510(K)
K
10
1678
ROMEO POSTERIOR OSTEOSYNTHESIS SYSTEM
2
Cleared 510(K)
K
10
0706
VENUS BASIC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
0956
SPONDY SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
10
0373
TYCHE PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
10
0605
MIS SYSTEM
2
Cleared 510(K)
K
09
3670
MODIFICATION TO: OASYS SYSTEM
2
Cleared 510(K)
K
10
0122
MODIFICATION TO CAPSURE PS SYSTEM
2
Cleared 510(K)
K
09
1725
PERFIX SPINAL SYSTEM, MODEL SNA4530-9610, SNM4530-9610, SN3020 (TOTAL: 549)
2
Cleared 510(K)
K
09
2011
NORM SPINAL SYSTEM
2
Cleared 510(K)
K
08
3077
ULC SPINAL PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
08
3567
GII SPINAL FIXATION SYSTEM, GII-TI-POLY AXIAL SCREW
2
Cleared 510(K)
K
09
0224
FORTEX PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
09
0477
ALPINE PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
09
1110
SPINAL EDGE TITAN PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
09
0424
DVX SPINE SYSTEM
2
Cleared 510(K)
K
09
0228
ROC LUMBAR PLATING SYSTEM
2
Cleared 510(K)
K
08
3581
LANX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
08
0611
MESA SPINAL SYSTEM
2
Cleared 510(K)
K
08
1153
NOVEL SPINAL SYSTEM
2
Cleared 510(K)
K
08
3826
LAGUNA POLYAXIAL PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
08
1165
ELLIPSE LUMBAR POSTERIOR OSTEOSYNTHESIS SYSTEM
2
Cleared 510(K)
K
08
2509
EOS SPINAL SYSTEM
2
Cleared 510(K)
K
08
2577
PASS LP SPINAL SYSTEM
2
Cleared 510(K)
K
08
1883
MODIFICATION TO PREFERENCE PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
08
2453
4CIS SOLAR AND APOLLON SPINE SYSTEMS
2
Cleared 510(K)
K
08
1331
FIXXSURE CROSS LINK
2
Cleared 510(K)
K
08
1631
SINTEA BIOTECH PLS MULTI-AXIAL SCREWS
2
Cleared 510(K)
K
08
1041
GPS, G SURGICAL PEDICLE SYSTEM
2
Cleared 510(K)
K
08
0828
MOUNTAINEER OCT SPINAL SYSTEM
2
Cleared 510(K)
K
08
1381
RANGE SPINAL SYSTEM, LARGE DENALI SCREWS
2
Cleared 510(K)
K
08
1296
PREFERENCE PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
08
0876
DVX SPINE SYSTEM
2
Cleared 510(K)
K
07
3531
ACCIN PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
07
1890
ZODIAC 4.0 POLYAXIAL SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
07
0530
MODIFICATION TO PASSMED SPINAL SYSTEM
2
Cleared 510(K)
K
07
2282
CAPLESS LI PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
07
0933
LOWTOP PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
06
2670
VERTIFLEX SPINAL SCREW SYSTEM
2
Cleared 510(K)
K
06
2174
MODIFICATION TO EXPEDIUM SPINE SYSTEM
2
Cleared 510(K)
K
06
1524
ISS INTEGRATED SPINE SYSTEM
2
Cleared 510(K)
K
06
1813
MANTIS SPINAL SYSTEM
2
Cleared 510(K)
K
06
1577
OVALTWIST PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
06
2196
SFX SNAP-FIT CROSS CONNECTOR
2
Cleared 510(K)
K
06
1364
PILOT POSTERIOR LUMBAR PLATING SYSTEM
2
Cleared 510(K)
K
06
2317
MODIFICATION TO NUVASIVE SPHERX II SYSTEM
2
Cleared 510(K)
K
06
1162
BAR PEDICLE SCREW SPINAL FIXATION SYSTEM, MODEL 2020
2
Cleared 510(K)
K
06
1915
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
06
1441
EBI 5.5 HELICAL FLANGE SPINAL SYSTEM
2
Cleared 510(K)
K
06
1778
NUVASIVE SPHERX II SYSTEM
2
Cleared 510(K)
K
05
3623
NFIX FUSION SYSTEM
2
Cleared 510(K)
K
06
1321
ZODIAC ADJUSTABLE BRIDGES, MODELS 11-20XX,11-25XX,11-30XX,11-35XX
2
Cleared 510(K)
K
06
0702
4CIS VANE SPINE SYSTEM
2
Cleared 510(K)
K
06
0118
SSP PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
06
0225
NUVASIVE SPHERX SYSTEM
2
Cleared 510(K)
K
05
3573
GSS PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
05
3070
CONTOUR II SPINAL SYSTEM
2
Cleared 510(K)
K
05
1089
GII SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
05
1959
NV CORMED SOLAS SPINAL SYSTEM
2
Cleared 510(K)
K
05
1044
ARCTEC SEMIRIGID PLATING SYSTEM
2
Cleared 510(K)
K
05
1697
SELECTIVE-AXIS POSTERIOR NONCERVICAL PLATING SYSTEM
2
Cleared 510(K)
K
05
0461
XIA 4.5 SPINAL SYSTEM
2
Cleared 510(K)
K
05
1216
HYDRALOK SYSTEM
2
Cleared 510(K)
K
05
1286
ZODIAC SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
05
0471
4CIS SOLAR SPINE SYSTEM AND 4CIS APOLLON SPINE SYSTEM
2
Cleared 510(K)
K
04
3578
THE 4CIS SPINAL SYSTEM AND 4CIS LOW BACK SYSTEM
2
Cleared 510(K)
K
04
3180
STRYKER SPINE TRIO PS
2
Cleared 510(K)
K
05
0078
ROC LUMBAR PLATING SYSTEM
2
Cleared 510(K)
K
04
2928
MODIFICATION TO GLOBAL SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
04
3152
VERTEBRON PSS PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
04
3343
MODIFICATION TO: CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
04
3001
MX POLYAXIAL PEDICLE SCREW
2
Cleared 510(K)
K
04
2640
UNI-THREAD SPINAL SYSTEM
2
Cleared 510(K)
K
04
2964
MX MONOAXIAL PEDICLE SCREW
2
Cleared 510(K)
K
04
0747
ALADYN RIGID SPINE PLATE
2
Cleared 510(K)
K
03
3512
PROCYON SPINAL SYSTEM
2
Cleared 510(K)
K
04
0442
PROTEX STABILIZATION SYSTEM
2
Cleared 510(K)
K
03
4056
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
03
3546
NUVASIVE SPINAL SYSTEM
2
Cleared 510(K)
K
04
0072
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
03
2604
GII SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
03
3322
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
03
2855
STRYKER SPINE MAPS SYSTEM
2
Cleared 510(K)
K
03
1265
SHIRAZ-JAVA SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
03
1585
U&I, OPTIMA, SPINAL SYSTEM
2
Cleared 510(K)
K
03
1423
EBI P148 SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
3378
ORIA CLARIS
2
Cleared 510(K)
K
03
0581
BLACKSTONE SPINAL FIXATION SYSTEM LATERAL OFFSET (SYSTEM MODIFICATION)
2
Cleared 510(K)
K
03
1290
MODIFICATION TO EASYS TRANSVERSE CONNECTION
2
Cleared 510(K)
K
03
0383
MODIFICATION TO MOSS MIAMI SPINAL SYSTEM POLYAXIAL SCREWS
2
Cleared 510(K)
K
02
3994
ORIA SPINAL CLIP SYSTEM, TYPES BD AND BJ
2
Cleared 510(K)
K
02
4348
MONARCH SPINE SYSTEM
2
Cleared 510(K)
K
02
0085
SINTEA BIOTECH POSTERIOR LUMBAR SYSTEM, MODEL PLS 00.T5.X
2
Cleared 510(K)
K
02
3438
MODIFICATION TO MONARCH SPINE SYSTEM
2
Cleared 510(K)
K
02
3204
MODIFICATION TO EBI OMEGA21 SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
1623
UCR SPINAL SYSTEM, 5.5MM, 8.0MM SCREWS & INSTRUMENTS
2
Cleared 510(K)
K
02
1881
ENDIUS TITLE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
0356
ALPHA MIRAGE TOP TIGHTENING SPINAL SYSTEM
2
Cleared 510(K)
K
02
0247
COLORADO 2 SPINAL SYSTEM
2
Cleared 510(K)
K
02
1335
MONARCH SPINE SYSTEM
2
Cleared 510(K)
K
02
1880
CROSSOVER CROSS CONNECTOR (MOSS MIAMI SPINE SYSTEM)
2
Cleared 510(K)
K
02
1879
CROSSOVER CROSS CONNECTOR (ISOLA SPINAL SYSTEM)
2
Cleared 510(K)
K
01
3962
EQUATION FIXATION SYSTEM
2
Cleared 510(K)
K
02
0699
TSRH SPINAL SYSTEM
2
Cleared 510(K)
K
02
1148
MONARCH SPINE SYSTEM COMMERCIALLY PURE TITANIUM SPINAL ROD
2
Cleared 510(K)
K
02
0681
EBI OMEGA21 SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
0674
BLACKSTONE SPINAL FIXATION SYSTEM 4.5MM MULTI-AXIAL SCREW
2
Cleared 510(K)
K
01
4302
UNIVERSAL MULTIAXIS (UNIMAX) PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
02
0196
MODIFICATION TO SILHOUETTE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
0293
OSTEONICS SPINAL SYSTEM
2
Cleared 510(K)
K
01
3887
BACFIX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
02
0245
MODIFICATION TO ISOBAR SPINAL SYSTEM
2
Cleared 510(K)
K
01
4229
MODIFICATION TO OPUS SPINAL SYSTEM
2
Cleared 510(K)
K
01
4137
MODIFICATION TO EBI OMEGA 21 SYSTEM
2
Cleared 510(K)
K
01
4076
MODIFICATION TO TSRH SPINAL SYSTEM
2
Cleared 510(K)
K
01
3688
MODIFICATION TO XIA SPINAL SYSTEM
2
Cleared 510(K)
K
01
3444
ISOBAR SPINAL SYSTEM
2
Cleared 510(K)
K
01
3295
TIMX SPINAL SYSTEMS
2
Cleared 510(K)
K
01
3294
MONARCH SPINAL SYSTEMS
2
Cleared 510(K)
K
01
3296
MOSS MIAMI SPINAL SYSTEMS
2
Cleared 510(K)
K
01
2971
ISOLA SPINAL SYSTEMS
2
Cleared 510(K)
K
01
2273
SPIRAL RADIUS 90-D SST SYSTEM
2
Cleared 510(K)
K
01
2027
MODIFICATION TO XIA SPINE SYSTEM
2
Cleared 510(K)
K
00
3733
SCS CLOSED SCREW
2
Cleared 510(K)
K
01
1182
MODIFIED MOSS MIAMI 4.35MM DIAMETER POLYAXIAL SCREWS
2
Cleared 510(K)
K
01
0369
CLARIS PLATE SYSTEM
2
Cleared 510(K)
K
01
0845
MODIFICATION TO OSTEONICS SPINAL SYSTEM
2
Cleared 510(K)
K
01
0742
MOSS MIAMI 5.5MM TITANIUM PIN NUT
2
Cleared 510(K)
K
01
0720
TSRH SPINAL SYSTEM
2
Cleared 510(K)
K
00
3463
SOCON SPINAL SYSTEM
2
Cleared 510(K)
K
01
0776
TRINITY POLYAXIAL SCREW, MEHDIAN SPINAL ROD (6MM), MODEL 159.XXX SERIES CATALOGUE NUMBERS
2
Cleared 510(K)
K
01
0535
TRIFIX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
01
0249
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
00
3764
MODIFICATION TO EBI SPINELINK SYSTEM
2
Cleared 510(K)
K
00
0641
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
00
3490
OPUS ROD FIXATION SYSTEM
2
Cleared 510(K)
K
00
3384
VERSALINK TITANIUM ROD-TO-ROD COUPLERS
2
Cleared 510(K)
K
00
1044
ACME SPINE SYSTEM - SERIES 6000, 7000, MONOAXIAL AND POLYAXIAL SCREW SYSTEM
2
Cleared 510(K)
K
00
1668
GLOBAL SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
00
2399
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
00
1255
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
00
1066
CD HORIZON ECLIPSE
2
Cleared 510(K)
K
00
1627
TRIFIX SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
00
1319
XIA SPINE SYSTEM HOOKS
2
Cleared 510(K)
K
00
1024
PASS SPINAL SYSTEM
2
Cleared 510(K)
K
99
1031
COLORADO II SPINAL SYSTEM
2
Cleared 510(K)
K
99
3503
HAIDER-UCR SPINAL SYSTEM
2
Cleared 510(K)
K
99
4288
5.0MM SPINAL SCREWS
2
Cleared 510(K)
K
98
4360
COLORADO II SPINAL SYSTEM
2
Cleared 510(K)
K
00
0476
MODIFICATION TO CD SPINAL SYSTEM
2
Cleared 510(K)
K
00
0453
MODIFICATION TO CD SPINAL SYSTEM
2
Cleared 510(K)
K
99
4217
BLACKSTONE SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
00
0094
MODIFICATION TO CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
99
2739
CLICK'X
2
Cleared 510(K)
K
00
0020
MODIFICATION TO ISOBAR SPINAL SYSTEM
2
Cleared 510(K)
K
99
3810
CD HORIZON SPINAL SYSTEM
2
Cleared 510(K)
K
99
3551
SOCON SPINAL SYSTEM
2
Cleared 510(K)
K
99
3926
OMNIAXIAL CONNECTOR
2
Cleared 510(K)
K
99
3808
SYNERGY INTEGRAL SCREWS, MODEL NUMBERS 2161,2162,2163,2164,2165,2166,2167,2168,2169,2210,2211,2212,2215,2216,2217,2220
2
Cleared 510(K)
K
99
1036
DANEK PLATE AND SCREW SYSTEM
2
Cleared 510(K)
K
99
1055
OSTEONICS SPINAL SYSTEM- ROD/ PLATE SYSTEM
2
Cleared 510(K)
K
99
1552
SYNTHES PEDIATRIC ROD SYSTEM
2
Cleared 510(K)
K
99
1528
MODIFICATION TO TENOR SPINAL SYSTEM-ROD/BOLT CONNECTOR
2
Cleared 510(K)
K
99
0721
ISOLOCK SPINAL SYSTEM
2
Cleared 510(K)
K
99
1460
MODIFICATION TO ZPLATE-ATL ANTERIOR FIXATION SYSTEM
2
Cleared 510(K)
K
99
1364
MODIFICATION TO TENOR SPINAL SYSTEM-PLATES
2
Cleared 510(K)
K
99
0657
TRIFIX PEDICLE SPINAL SCREW ASSEMBLY
2
Cleared 510(K)
K
99
0118
ISOBAR SPINAL SYSTEM
2
Cleared 510(K)
K
98
4302
OSTEONICS SPINAL SYSTEM CYLINDRICAL BONE SCREWS
2
Cleared 510(K)
K
98
3152
OSTEONICS SPINAL SYSTEM 5.5MM & 10.0MM BONE SCREWS
2
Cleared 510(K)
K
98
0761
SYNTHES SPINE PEDIATRIC ROD SYSTEM
2
Cleared 510(K)
K
98
1714
TIMX LOW BACK SYSTEM TITANIUM MX ROD BASED LOW BACK SYSTEM
2
Cleared 510(K)
K
98
1113
PEDIATRIC PRC
2
Cleared 510(K)
K
98
0862
TITANIUM SPINAL ROD SYSTEM
2
Cleared 510(K)
K
98
0852
GII SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
98
1274
ACROMED TIMX PLATE BASED LOW BACK SYSTEM
2
Cleared 510(K)
K
98
0496
WRIGHT MEDICAL TECHNOLOGY ROD-TO-ROD COUPLER
2
Cleared 510(K)
K
98
0447
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
97
3687
SPINAL CONCEPTS, INC., BACFIX TI SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
97
4749
SYNERGY CLOSED VARIABLE LOCKING SCREW (VLS), PART OF THE CROSS MEDICAL-SYNERGY ANTERIOR AND POSTERIOR SPINAL SYSTEMS
2
Cleared 510(K)
K
97
4734
AURORA TITANIUM SPINAL ROD SYSTEM
2
Cleared 510(K)
K
97
3836
SYNERGY 6.35MM SS ROD WITH SCREWS FOR ANTERIOR USE, PART OF THE CROSS MEDICAL-SYNERGY ANTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
97
3425
THE MEHDIAN LUMBO-SACRAL PEDICLE SCREW SYSTEM
2
Cleared 510(K)
K
97
4213
AURORA TITANIUM SPINAL ROD SYSTEM
2
Cleared 510(K)
K
97
3683
OMEGA 21 SYSTEM
2
Cleared 510(K)
K
97
2568
DEPUY MOTECH MOSS-MIAMI SPINAL SYSTEM
2
Cleared 510(K)
K
97
1970
EBI SPINELINK SYSTEM
2
Cleared 510(K)
K
97
0285
AESUCLAP SOCON SPINAL SYSTEM
2
Cleared 510(K)
K
97
0950
EASY ROD
2
Cleared 510(K)
K
96
5102
ACROMED PEDICLE SCREW
2
Cleared 510(K)
K
96
4533
EBI SPINELINK SYSTEM
2
Cleared 510(K)
K
96
5046
ISOLA TWISTER CONNECTOR
2
Cleared 510(K)
K
96
3045
SYNTHES (U.S.A.) UNIVERSAL SACRAL SYSTEM
2
Cleared 510(K)
K
96
4544
OSTEONICS SPINAL SYSTEM - VARIABLE OFFSET CONNECTOR ASSEMBLY
2
Cleared 510(K)
K
96
4304
OSTEONICS SPINAL SYSTEM-TOPLOADING TRANSVERSE CONNECTOR ASSEMBLY
2
Cleared 510(K)
K
95
0099
SYNERGY(TM) TI POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
96
3357
MODIFICATION TO THE SYNTHES (USA) UNIVERSAL SPINAL HOOK, ROD, AND AND SACRAL SCREW FIXATION SYSTEM IN 316L STAINLESS STE
2
Cleared 510(K)
K
96
4007
ACROMED CABLE/WIRE PEDICLE SCREW
2
Cleared 510(K)
K
96
2608
SYNTHES (U.S.A.) UNIVERSAL SPINAL PARALLEL CONNECTOR
2
Cleared 510(K)
K
96
2645
ISOLA TWISTER CONNECTOR
2
Cleared 510(K)
K
96
2784
ULTIUM SPINAL PLATING SYSTEM
2
Cleared 510(K)
K
96
2757
J.B.S. SPINE SYSTEM WITH PEDICLE SCREWS - ADDITIONAL COMPONENTS - SCREWS, LINKING PLATES, HOOKS AND ROD CLAMP
2
Cleared 510(K)
K
96
1572
VERSALOK SCREW ASSEMBLY (PROPOSED NAME)
2
Cleared 510(K)
K
96
0107
DDS SPINAL SYSTEM
2
Cleared 510(K)
K
96
0451
WEBB-MORLEY SPINE SYSTEM
2
Cleared 510(K)
K
95
3881
SPINE SYSTEM SACRAL PLATE
2
Cleared 510(K)
K
95
3915
MOSS MIAMI SPINAL SYSTEM (ANTERIOR USE)
2
Cleared 510(K)
K
95
0717
AUGMENT-T POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
94
3827
SPINE FIXATION
2
Cleared 510(K)
K
95
0999
KSF POSTERIOR SPINGAL FIXATOR FOR SEVERE SPONDYLOLISTHESIS
2
Cleared 510(K)
K
95
2236
ISOLA SYSTEM
2
Cleared 510(K)
K
95
2298
SPINAL PEDICLE SCREW, FIXATION, APPLIANCE
2
Cleared 510(K)
K
95
1266
AMSET R-F SYSTEM
2
Cleared 510(K)
K
95
3779
SADDLE WITH ANCHOR, STAINLESS STEEL VARIFIX SYSTEM
2
Cleared 510(K)
K
95
3778
SADDLE WITH ANCHOR, TITANIUM VARIFIX SYSTEM
2
Cleared 510(K)
K
95
3635
TITANIUM DYNA-LOK SPINAL SYSTEM
2
Cleared 510(K)
K
95
3416
BRYAN POSTERIOR SPINAL FIXATOR (BPSF)
2
Cleared 510(K)
K
95
3369
STAINLESS STEEL VARIFIX SYSTEM 5.0MM DIAMETER ANCHOR SCREW
2
Cleared 510(K)
K
95
1725
OSTEONICS SPINAL SYSTEM
2
Cleared 510(K)
K
95
0865
ROGOZINSKI SPINAL ROD SYSTEM ROD-TO-BOLT (UNIVERSAL) CONNECTOR FOR USE WITH THE SIMMONS PLATING SYSTEM BOLT
2
Cleared 510(K)
K
95
0596
GDLH POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
95
0955
PARAGON POSTERIOR SPINAL SYSTEM
2
Cleared 510(K)
K
95
1657
VSP (VARIABLE SCREW PLACEMENT) SPINAL FIXATION SYSTEM, PEDICLE SCREW(S), SPINE PLATE(S), WASHER(S) & NUT(S)
2
Cleared 510(K)
K
95
1626
SYNTHES (U.S.A.) UNIVERSAL SPINAL HOOK, ROD AND PEDICLE/SACRAL SCREW FIXATION SYSTEM
2
Cleared 510(K)
K
95
1794
SYNTHES (USA) UNIV. SCREW FIXATION SYSTEM (TITANIUM)
2
Cleared 510(K)
K
93
6307
DYNA-LOK ANTERIOR PLATING SYSTEM
2
Cleared 510(K)
K
95
1116
ACROMED PEDICLE SCREW
2
Cleared 510(K)
K
95
0074
WRIGHT-LOC(TM) SPINAL FIXATION SYSTEM
2
Cleared 510(K)
K
94
6348
TITANIUM TSRH(R) SPINAL SYSTEM (SCREWS)
2
Cleared 510(K)
K
95
1308
5.8MM DIAMETER ANCHOR SCREW
2
Cleared 510(K)
K
95
1172
TITANIUM LOW PROFILE CROSS BAR
2
Cleared 510(K)
K
95
0695
DEPUY MOTECH MOSS SPINAL SYSTEM - PEDICLE FIXATION
2
Cleared 510(K)
K
94
0631
CROSS MEDICAL - SYNERGY(TM) SPINE SYSTEM
2
Cleared 510(K)
K
95
0697
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM - PEDICLE FIXATION
2
Cleared 510(K)
K
94
4737
ISOLA SPINE SYSTEM
2
Cleared 510(K)
K
93
0353
SIMMONS PLATING SYSTEM BOLT AND SCREW
2
Cleared 510(K)
K
93
0298
ROGOZINSKI SPINAL ROD SYSTEM SCREW
2
Cleared 510(K)
K
94
4756
ISOLA OPEN AND CLOSED SCREWS
2
Cleared 510(K)
K
94
4736
VSP (VARIABLE SCREW PLACEMENT)
2
Cleared 510(K)
K
94
5064
SELBY INSTRUMENTATION
2
Cleared 510(K)
K
94
3775
SELBY INSTRUMENTATION
2
Cleared 510(K)
K
94
2387
SELBY INSTRUMENTATION
2
Cleared 510(K)
K
93
2029
TSRH SPINAL SCREWS
2
Cleared 510(K)
MNI
Orthosis, Spinal Pedicle Fixation
2
Product Code
MNU
Staple, Absorbable
2
Product Code
MQP
Spinal Vertebral Body Replacement Device
2
Product Code
MQV
Filler, Bone Void, Calcium Compound
2
Product Code
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
2
Product Code
NDD
Cerclage, Fixation, Metallic
2
Product Code
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
2
Product Code
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
2
Product Code
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
2
Product Code
NDK
System, External Fixator (With Metallic Invasive Components)
2
Product Code
NDL
Pin, Fixation, Smooth, Metallic
2
Product Code
NDM
Pin, Fixation, Threaded, Metallic
2
Product Code
NDN
Cement, Bone, Vertebroplasty
2
Product Code
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
2
Product Code
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
2
Product Code
NKB
Thoracolumbosacral Pedicle Screw System
2
Product Code
NKG
Posterior Cervical Screw System
2
Product Code
NOV
Anchor, Suture, Bone Fixation, Metallic
2
Product Code
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
2
Product Code
NQP
Posterior Metal/Polymer Spinal System, Fusion
2
Product Code
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
2
Product Code
NUD
Vertebroplasty Compound, Calcium Based
2
Product Code
NVC
Bone, Heterograft
3
Product Code
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
2
Product Code
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
2
Product Code
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
2
Product Code
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
2
Product Code
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
3
Product Code
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
2
Product Code
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
2
Product Code
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
2
Product Code
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
2
Product Code
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
2
Product Code
OOG
Knee Arthroplasty Implantation System
2
Product Code
OOL
Electronic Depth Gauge
2
Product Code
OQB
Intervertebral Body Graft Containment Device
2
Product Code
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
2
Product Code
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
2
Product Code
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
2
Product Code
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
2
Product Code
OSN
Software For Diagnosis/Treatment
2
Product Code
OUR
Sacroiliac Joint Fixation
2
Product Code
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
2
Product Code
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
2
Product Code
OVZ
Pin, Fixation, Resorbable, Hard Tissue
2
Product Code
OWI
Bone Fixation Cerclage, Sublaminar
2
Product Code
OYK
Ankle Arthroplasty Implantation System
2
Product Code
OZI
Internal Hinged Elbow Fixator
2
Product Code
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
2
Product Code
PBF
Orthopaedic Surgical Planning And Instrument Guides
2
Product Code
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
2
Product Code
PEK
Spinous Process Plate
2
Product Code
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
2
Product Code
PHQ
Anterior Staple As Supplemental Fixation For Fusion
2
Product Code
PHX
Shoulder Prosthesis, Reverse Configuration
2
Product Code
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
2
Product Code
PLF
Bone Wedge
2
Product Code
PLR
Spinal Vertebral Body Replacement Device - Cervical
2
Product Code
PLW
Acetabular Cup Orientation System
2
Product Code
PML
Bone Cement, Posterior Screw Augmentation
2
Product Code
PPQ
Transtibial Anterior Cruciate Ligament Kit
2
Product Code
QHQ
Total Shoulder Arthroplasty System
2
Product Code
PQC
Pedicle Screw Placement Guide
2
Product Code
QAC
Screw Sleeve Bone Fixation Device
2
Product Code
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
2
Product Code
QFP
Intraoperative Orthopedic Strain Sensor
2
Product Code
QHE
Shoulder Arthroplasty Implantation System
2
Product Code
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
2
Product Code
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
2
Product Code
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
2
Product Code
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
2
Product Code
JDK
Prosthesis, Hip, Cement Restrictor
2
Product Code
LZN
Cement Obturator
2
Product Code
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
2
Product Code
QSD
Posterior Cervical Screw Placement Guide
2
Product Code
QSR
Sacroiliac Screw Placement Guide
2
Product Code
QVI
Screw Sleeve Bone Fixation Device, Spine
2
Product Code
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
2
Product Code
SAI
Ankle Fusion Cage
2
Product Code
SCY
Sacroiliac Joint Guidewire Placement Device
2
Product Code
Subpart E—Neurological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
OR
/
subpart-d—prosthetic-devices
/
MNH
/
K061813
View Source
MANTIS SPINAL SYSTEM
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K061813
510(k) Type
Traditional
Applicant
Stryker Spine
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
9/19/2006
Days to Decision
84 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Miscellaneous
Subpart B—Diagnostic Devices
Subpart D—Prosthetic Devices
NDH
Nail, Fixation, Bone, Metallic
HRY
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
HRZ
Prosthesis, Knee, Hinged (Metal-Metal)
HSA
Prosthesis, Knee, Hemi-, Femoral
HSB
Rod, Fixation, Intramedullary And Accessories
NDI
Staple, Fixation, Bone, Metallic
HRS
Plate, Fixation, Bone
HSD
Prosthesis, Shoulder, Hemi-, Humeral, Metallic Uncemented
HSH
Prosthesis, Knee, Hemi-, Tibial, Resurfacing (Uncemented)
HSN
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
HSX
Prosthesis, Knee, Femorotibial, Non-Constrained, Cemented, Metal/Polymer
HTG
Prosthesis, Knee, Hemi-, Patellar Resurfacing, Uncemented
HTN
Washer, Bolt Nut
HTY
Pin, Fixation, Smooth
HWC
Screw, Fixation, Bone
HXA
Prosthesis, Tendon, Passive
JDB
Prosthesis, Elbow, Semi-Constrained, Cemented
JDC
Prosthesis, Elbow, Constrained, Cemented
JDD
Prosthesis, Upper Femoral
JDG
Prosthesis, Hip, Femoral Component, Cemented, Metal
JDH
Prosthesis, Hip, Hemi-, Trunnion-Bearing, Femoral, Metal/Polyacetal
JDI
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented
JDL
Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component)
JDN
Implant, Fixation Device, Spinal
JDO
Device, Fixation, Proximal Femoral, Implant
JDP
Condylar Plate Fixation Implant
JDQ
Cerclage, Fixation
JDR
Staple, Fixation, Bone
JDS
Nail, Fixation, Bone
JDT
Cap, Bone
JDW
Pin, Fixation, Threaded
JEC
Component, Traction, Invasive
JWH
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
JWI
Prosthesis, Wrist, 2 Part Metal-Plastic Articulation, Semi-Constrained
JWJ
Prosthesis, Wrist, 3 Part Metal-Plastic-Metal Articulation, Semi-Constrained
KIG
Prosthesis, Wrist, Constrained, Polymer
KMB
Prosthesis, Knee, Non-Constrained (Metal-Carbon Reinforced Polyethylene) Cemented
KMC
Prosthesis, Hip, Semi-Constrained, Composite/Metal
KMD
Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Composite
KRN
Metal Cemented Constrained Femorotibial Knee Prosthesis
KRO
Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer
KRP
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Metal
KRQ
Prosthesis, Knee, Patello/Femorotibial, Constrained, Cemented, Polymer/Metal/Polymer
KRR
Prosthesis, Knee, Patello/Femoral, Semi-Constrained, Cemented, Metal/Polymer
KRS
Prosthesis, Knee, Hemi-, Femoral (Uncemented)
KTT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component
KTW
Appliance, Fixation, Nail/Blade/Plate Combination, Single Component
KTX
Prosthesis, Knee, Femorotibial, Non-Constrained, Metal/Composite Cemented
KWA
Prosthesis, Hip, Semi-Constrained (Metal Uncemented Acetabular Component)
KWB
Prosthesis, Hip, Hemi-, Acetabular, Cemented, Metal
KWD
Prosthesis, Toe, Hemi-, Phalangeal
KWE
Prosthesis, Finger, Constrained, Metal, Uncemented
KWF
Prosthesis, Finger, Polymer
KWG
Prosthesis, Finger, Constrained, Metal/Polymer
KWH
Prosthesis, Toe, Constrained, Polymer
KWI
Prosthesis, Elbow, Hemi-, Radial, Polymer
KWJ
Prosthesis, Elbow, Hemi-, Humeral, Metal
KWK
Appliance, Nail/Blade/Plate Combination, Single Component
KWL
Prosthesis, Hip, Hemi-, Femoral, Metal
KWM
Prosthesis, Wrist, Semi-Constrained
KWN
Prosthesis, Wrist, Carpal Lunate
KWO
Prosthesis, Wrist, Carpal Scaphoid
KWP
Appliance, Fixation, Spinal Interlaminal
KWQ
Appliance, Fixation, Spinal Intervertebral Body
KWR
Prosthesis, Shoulder, Constrained, Metal/Metal Or Metal/Polymer Cemented
KWS
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer Cemented
KWT
Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented
KWY
Prosthesis, Hip, Hemi-, Femoral, Metal/Polymer, Cemented Or Uncemented
KWZ
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer
KXA
Prosthesis, Hip, Femoral, Resurfacing
KXB
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer
KXC
Prosthesis, Ankle, Cemented, Non-Constrained
KXD
Prosthesis, Hip, Constrained, Metal
KXE
Prosthesis, Wrist, Hemi-, Ulnar
KYI
Prosthesis, Wrist, Carpal Trapezium
KYJ
Prosthesis, Finger, Constrained, Polymer
KYK
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Composite
KYM
Metallic Cemented Glenoid Hemi-Shoulder Prosthesis
KYN
Prosthesis, Wrist, Constrained, Metal
LBC
Prosthesis, Finger, Constrained, Metal, Cemented
LGE
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Trunnion-Bearing
LOD
Bone Cement
LPH
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
LRN
Wire, Surgical
LTO
Spacer, Cement
LWJ
Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented
LXT
Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component, Metal Composite
LYP
Accessories, Fixation, Spinal Interlaminal
LYT
Fixation Accessory
LZO
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented
LZY
Prosthesis, Hip, Hemi-, Femoral, Metal Ball
MAI
Fastener, Fixation, Biodegradable, Soft Tissue
MAX
Intervertebral Fusion Device With Bone Graft, Lumbar
MAY
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous Cemented, Osteophilic Finish
MBB
Bone Cement, Antibiotic
MBF
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer, Uncemented
MBH
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
MBI
Fastener, Fixation, Nondegradable, Soft Tissue
MBL
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Porous
MBP
Filler, Bone Void, Osteoinduction (W/O Human Growth Factor)
MBV
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uhmwpe, Pegged, Cemented, Polymer/Metal/Polymer
MEH
Prosthesis, Hip, Semi-Constrained, Uncemented, Metal / Polymer, Non-Porous, Calcium Phosphate
MJW
Prosthesis, Subtalar, Plug, Polymer
MNH
Orthosis, Spondylolisthesis Spinal Fixation
K
16
2066
Reliance Spinal Screw System
K
16
2801
CastleLoc Spinal Fixation System
K
16
2143
FixxSure® X-Link
K
16
1151
Spinal fixation system
K
16
2189
ANAX™ 5.5 Spinal System
K
15
1362
HC Spinal System
K
15
3404
Zavation Spinal System
K
16
0020
Captiva Spine and CapLOX II/TowerLOX Pedicle Screw System
K
14
3013
Spinal Inner Fixation System
K
15
1695
Romeo posterior osteosynthesis system
K
15
1116
CapLOX II/TowerLOX Pedicle Screw System
K
15
0283
Republic Spine Dark Star Spinal System
K
14
2798
PASS LP Spinal System
K
14
3417
ANAX 5.5 Spinal System
K
14
3377
PedFuse Pedicle Screw System
K
14
2957
Ideal pedicle screw spinal system
K
14
2655
CB PROT II Posterior Spinal System
K
14
0359
MAXIMIS SPINAL FIXATION SYSTEM
K
14
2290
KangLi pedical screw spinal system
K
13
4011
GENERAL SPINAL SYSTEM
K
13
3575
SPINEVISION LUMIS CANNULATED PEDICLE SCREW FIXATION SYSTEM, SPINEVISION U.L.I.S. PEDICLE SCREW FIXATION SYSTEM
K
14
1376
INERTIA PEDICLE SCREW SYSTEM, HONOUR SPACER SYSTEM, FACET FIXX, STRUXXURE ANTERIOR CERVICAL PLATE AND SCREWS
K
14
0053
KANGLI PEDICLE SCREW SPINAL SYSTEM
K
14
0678
COSMOLOCK PEDICLE SCREW SYSTEM
K
14
0787
PLS (POSTERIOR LUMBAR SYSTEM)
K
14
0948
ROMEO POSTERIOR OSTEOSYNTHESIS SYSTEM
K
13
3153
SPINEFRONTIER PEDFUSE PEDICLE SCREW SYSTEM
K
13
3690
TRUE SPINAL FUSSION SYSTEM
K
13
3287
PRESSON SPINAL FIXATION SYSTEM
K
13
2403
ANNEXTM ADJACENT LEVEL SYSTEM
K
13
2218
PERFIX ILIAC SCREW SYSTEM
K
13
2101
ANAX 5.5 SPINAL SYSTEM
K
13
1810
OSSEUS BLACK DIAMOND PEDICLE SCREW SYSTEM
K
13
1538
CAPLOX II PEDICLE SCREW SYSTEM/TOWERLOX PEDICLE SCREW SYSTEM
K
13
0267
ROMEO POSTERIOR OSTEOSYNTHESIS SYSTEM
K
12
2994
INTRAMEDULLARY NAIL SYSTEM
K
12
3487
GSO GS1 CANNULATED SCREW SYSTEM
K
12
3164
SPINEFRONTIER PEDFUSE PEDICLE SCREW SYSTEM
K
12
3476
MEGA 5.5 SPINE SYSTEM
K
12
2592
INSTINCT JAVA SYSTEM
K
12
2814
GALLEON PEDICLE SCREW SYSTEM
K
12
0832
FORTEX PEDICLE SCREW SYSTEM
K
12
1016
RANGE SPINAL SYSTEM (MESA AND DENALI)
K
12
0760
LDR SPINE SPINETUNE TL SPINAL SYSTEM
K
11
1940
S 100 PEDICLE SCREW SYSTEM
K
12
0491
DSS STABILIZATION SYSTEM-RIGID
K
12
0353
SYNSTER PEDICLE SCREW SYSTEM SYNSTER PLUS PEDICLE SCREW SYSTEM
K
10
3573
ARTS2 SPINAL FIXATION SYSTEM
K
11
0633
LANCER PEDICLE SCREW SYSTEM
K
11
1995
XINGTM SPINE SYSTEM
K
11
1690
DEVINE SPINAL SYSTEM
K
11
0497
PASS LP SPINAL SYSTEM
K
11
1370
ODALYS PEDICLE SCREW SYSTEM
K
11
1362
REXIOUS SPINAL FIXATION SYSTEM
K
10
2458
4CIS SOLAR SPINE SYSTEM AND 4CIS APOLLON SPINE SYSTEM
K
11
0321
TIGER SPINE SYSTEM
K
10
1374
AAXTER A3 POSTERIOR SPINAL SYSTEM
K
10
2574
PALLA M SPINAL SYSTEM
K
10
2636
ZENITH PEDICLE SYSTEM
K
10
1818
4CIS VANE SPINE SYSTEM
K
10
3085
VENUS BASIC SPINAL FIXATION SYSTEM
K
10
2853
FLAMENCO SPINAL FIXATION SYSTEM
K
10
2870
EXACTECH PROLIANT POLYAXIAL PEDICLE SCREW SYSTEM
K
10
1446
EMERALD SPINAL SYSTEM
K
10
1278
INERTIA PEDICLE SCREW SYSTEM
K
10
2488
APEX SPINE SYSTEM W/ COCR RODS
K
09
3771
QUANTUM/STREAMLINE TL MIS SPINAL SYSTEM
K
10
1678
ROMEO POSTERIOR OSTEOSYNTHESIS SYSTEM
K
10
0706
VENUS BASIC SPINAL FIXATION SYSTEM
K
10
0956
SPONDY SPINAL FIXATION SYSTEM
K
10
0373
TYCHE PEDICLE SCREW SYSTEM
K
10
0605
MIS SYSTEM
K
09
3670
MODIFICATION TO: OASYS SYSTEM
K
10
0122
MODIFICATION TO CAPSURE PS SYSTEM
K
09
1725
PERFIX SPINAL SYSTEM, MODEL SNA4530-9610, SNM4530-9610, SN3020 (TOTAL: 549)
K
09
2011
NORM SPINAL SYSTEM
K
08
3077
ULC SPINAL PEDICLE SCREW SYSTEM
K
08
3567
GII SPINAL FIXATION SYSTEM, GII-TI-POLY AXIAL SCREW
K
09
0224
FORTEX PEDICLE SCREW SYSTEM
K
09
0477
ALPINE PEDICLE SCREW SYSTEM
K
09
1110
SPINAL EDGE TITAN PEDICLE SCREW SYSTEM
K
09
0424
DVX SPINE SYSTEM
K
09
0228
ROC LUMBAR PLATING SYSTEM
K
08
3581
LANX SPINAL FIXATION SYSTEM
K
08
0611
MESA SPINAL SYSTEM
K
08
1153
NOVEL SPINAL SYSTEM
K
08
3826
LAGUNA POLYAXIAL PEDICLE SCREW SYSTEM
K
08
1165
ELLIPSE LUMBAR POSTERIOR OSTEOSYNTHESIS SYSTEM
K
08
2509
EOS SPINAL SYSTEM
K
08
2577
PASS LP SPINAL SYSTEM
K
08
1883
MODIFICATION TO PREFERENCE PEDICLE SCREW SYSTEM
K
08
2453
4CIS SOLAR AND APOLLON SPINE SYSTEMS
K
08
1331
FIXXSURE CROSS LINK
K
08
1631
SINTEA BIOTECH PLS MULTI-AXIAL SCREWS
K
08
1041
GPS, G SURGICAL PEDICLE SYSTEM
K
08
0828
MOUNTAINEER OCT SPINAL SYSTEM
K
08
1381
RANGE SPINAL SYSTEM, LARGE DENALI SCREWS
K
08
1296
PREFERENCE PEDICLE SCREW SYSTEM
K
08
0876
DVX SPINE SYSTEM
K
07
3531
ACCIN PEDICLE SCREW SYSTEM
K
07
1890
ZODIAC 4.0 POLYAXIAL SPINAL FIXATION SYSTEM
K
07
0530
MODIFICATION TO PASSMED SPINAL SYSTEM
K
07
2282
CAPLESS LI PEDICLE SCREW SYSTEM
K
07
0933
LOWTOP PEDICLE SCREW SYSTEM
K
06
2670
VERTIFLEX SPINAL SCREW SYSTEM
K
06
2174
MODIFICATION TO EXPEDIUM SPINE SYSTEM
K
06
1524
ISS INTEGRATED SPINE SYSTEM
K
06
1813
MANTIS SPINAL SYSTEM
K
06
1577
OVALTWIST PEDICLE SCREW SYSTEM
K
06
2196
SFX SNAP-FIT CROSS CONNECTOR
K
06
1364
PILOT POSTERIOR LUMBAR PLATING SYSTEM
K
06
2317
MODIFICATION TO NUVASIVE SPHERX II SYSTEM
K
06
1162
BAR PEDICLE SCREW SPINAL FIXATION SYSTEM, MODEL 2020
K
06
1915
CD HORIZON SPINAL SYSTEM
K
06
1441
EBI 5.5 HELICAL FLANGE SPINAL SYSTEM
K
06
1778
NUVASIVE SPHERX II SYSTEM
K
05
3623
NFIX FUSION SYSTEM
K
06
1321
ZODIAC ADJUSTABLE BRIDGES, MODELS 11-20XX,11-25XX,11-30XX,11-35XX
K
06
0702
4CIS VANE SPINE SYSTEM
K
06
0118
SSP PEDICLE SCREW SYSTEM
K
06
0225
NUVASIVE SPHERX SYSTEM
K
05
3573
GSS PEDICLE SCREW SYSTEM
K
05
3070
CONTOUR II SPINAL SYSTEM
K
05
1089
GII SPINAL FIXATION SYSTEM
K
05
1959
NV CORMED SOLAS SPINAL SYSTEM
K
05
1044
ARCTEC SEMIRIGID PLATING SYSTEM
K
05
1697
SELECTIVE-AXIS POSTERIOR NONCERVICAL PLATING SYSTEM
K
05
0461
XIA 4.5 SPINAL SYSTEM
K
05
1216
HYDRALOK SYSTEM
K
05
1286
ZODIAC SPINAL FIXATION SYSTEM
K
05
0471
4CIS SOLAR SPINE SYSTEM AND 4CIS APOLLON SPINE SYSTEM
K
04
3578
THE 4CIS SPINAL SYSTEM AND 4CIS LOW BACK SYSTEM
K
04
3180
STRYKER SPINE TRIO PS
K
05
0078
ROC LUMBAR PLATING SYSTEM
K
04
2928
MODIFICATION TO GLOBAL SPINAL FIXATION SYSTEM
K
04
3152
VERTEBRON PSS PEDICLE SCREW SYSTEM
K
04
3343
MODIFICATION TO: CD HORIZON SPINAL SYSTEM
K
04
3001
MX POLYAXIAL PEDICLE SCREW
K
04
2640
UNI-THREAD SPINAL SYSTEM
K
04
2964
MX MONOAXIAL PEDICLE SCREW
K
04
0747
ALADYN RIGID SPINE PLATE
K
03
3512
PROCYON SPINAL SYSTEM
K
04
0442
PROTEX STABILIZATION SYSTEM
K
03
4056
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
03
3546
NUVASIVE SPINAL SYSTEM
K
04
0072
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
03
2604
GII SPINAL FIXATION SYSTEM
K
03
3322
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
03
2855
STRYKER SPINE MAPS SYSTEM
K
03
1265
SHIRAZ-JAVA SPINAL FIXATION SYSTEM
K
03
1585
U&I, OPTIMA, SPINAL SYSTEM
K
03
1423
EBI P148 SPINAL FIXATION SYSTEM
K
02
3378
ORIA CLARIS
K
03
0581
BLACKSTONE SPINAL FIXATION SYSTEM LATERAL OFFSET (SYSTEM MODIFICATION)
K
03
1290
MODIFICATION TO EASYS TRANSVERSE CONNECTION
K
03
0383
MODIFICATION TO MOSS MIAMI SPINAL SYSTEM POLYAXIAL SCREWS
K
02
3994
ORIA SPINAL CLIP SYSTEM, TYPES BD AND BJ
K
02
4348
MONARCH SPINE SYSTEM
K
02
0085
SINTEA BIOTECH POSTERIOR LUMBAR SYSTEM, MODEL PLS 00.T5.X
K
02
3438
MODIFICATION TO MONARCH SPINE SYSTEM
K
02
3204
MODIFICATION TO EBI OMEGA21 SPINAL FIXATION SYSTEM
K
02
1623
UCR SPINAL SYSTEM, 5.5MM, 8.0MM SCREWS & INSTRUMENTS
K
02
1881
ENDIUS TITLE SPINAL FIXATION SYSTEM
K
02
0356
ALPHA MIRAGE TOP TIGHTENING SPINAL SYSTEM
K
02
0247
COLORADO 2 SPINAL SYSTEM
K
02
1335
MONARCH SPINE SYSTEM
K
02
1880
CROSSOVER CROSS CONNECTOR (MOSS MIAMI SPINE SYSTEM)
K
02
1879
CROSSOVER CROSS CONNECTOR (ISOLA SPINAL SYSTEM)
K
01
3962
EQUATION FIXATION SYSTEM
K
02
0699
TSRH SPINAL SYSTEM
K
02
1148
MONARCH SPINE SYSTEM COMMERCIALLY PURE TITANIUM SPINAL ROD
K
02
0681
EBI OMEGA21 SPINAL FIXATION SYSTEM
K
02
0674
BLACKSTONE SPINAL FIXATION SYSTEM 4.5MM MULTI-AXIAL SCREW
K
01
4302
UNIVERSAL MULTIAXIS (UNIMAX) PEDICLE SCREW SYSTEM
K
02
0196
MODIFICATION TO SILHOUETTE SPINAL FIXATION SYSTEM
K
02
0293
OSTEONICS SPINAL SYSTEM
K
01
3887
BACFIX SPINAL FIXATION SYSTEM
K
02
0245
MODIFICATION TO ISOBAR SPINAL SYSTEM
K
01
4229
MODIFICATION TO OPUS SPINAL SYSTEM
K
01
4137
MODIFICATION TO EBI OMEGA 21 SYSTEM
K
01
4076
MODIFICATION TO TSRH SPINAL SYSTEM
K
01
3688
MODIFICATION TO XIA SPINAL SYSTEM
K
01
3444
ISOBAR SPINAL SYSTEM
K
01
3295
TIMX SPINAL SYSTEMS
K
01
3294
MONARCH SPINAL SYSTEMS
K
01
3296
MOSS MIAMI SPINAL SYSTEMS
K
01
2971
ISOLA SPINAL SYSTEMS
K
01
2273
SPIRAL RADIUS 90-D SST SYSTEM
K
01
2027
MODIFICATION TO XIA SPINE SYSTEM
K
00
3733
SCS CLOSED SCREW
K
01
1182
MODIFIED MOSS MIAMI 4.35MM DIAMETER POLYAXIAL SCREWS
K
01
0369
CLARIS PLATE SYSTEM
K
01
0845
MODIFICATION TO OSTEONICS SPINAL SYSTEM
K
01
0742
MOSS MIAMI 5.5MM TITANIUM PIN NUT
K
01
0720
TSRH SPINAL SYSTEM
K
00
3463
SOCON SPINAL SYSTEM
K
01
0776
TRINITY POLYAXIAL SCREW, MEHDIAN SPINAL ROD (6MM), MODEL 159.XXX SERIES CATALOGUE NUMBERS
K
01
0535
TRIFIX SPINAL FIXATION SYSTEM
K
01
0249
CD HORIZON SPINAL SYSTEM
K
00
3764
MODIFICATION TO EBI SPINELINK SYSTEM
K
00
0641
CD HORIZON SPINAL SYSTEM
K
00
3490
OPUS ROD FIXATION SYSTEM
K
00
3384
VERSALINK TITANIUM ROD-TO-ROD COUPLERS
K
00
1044
ACME SPINE SYSTEM - SERIES 6000, 7000, MONOAXIAL AND POLYAXIAL SCREW SYSTEM
K
00
1668
GLOBAL SPINAL FIXATION SYSTEM
K
00
2399
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
00
1255
CD HORIZON SPINAL SYSTEM
K
00
1066
CD HORIZON ECLIPSE
K
00
1627
TRIFIX SPINAL FIXATION SYSTEM
K
00
1319
XIA SPINE SYSTEM HOOKS
K
00
1024
PASS SPINAL SYSTEM
K
99
1031
COLORADO II SPINAL SYSTEM
K
99
3503
HAIDER-UCR SPINAL SYSTEM
K
99
4288
5.0MM SPINAL SCREWS
K
98
4360
COLORADO II SPINAL SYSTEM
K
00
0476
MODIFICATION TO CD SPINAL SYSTEM
K
00
0453
MODIFICATION TO CD SPINAL SYSTEM
K
99
4217
BLACKSTONE SPINAL FIXATION SYSTEM
K
00
0094
MODIFICATION TO CD HORIZON SPINAL SYSTEM
K
99
2739
CLICK'X
K
00
0020
MODIFICATION TO ISOBAR SPINAL SYSTEM
K
99
3810
CD HORIZON SPINAL SYSTEM
K
99
3551
SOCON SPINAL SYSTEM
K
99
3926
OMNIAXIAL CONNECTOR
K
99
3808
SYNERGY INTEGRAL SCREWS, MODEL NUMBERS 2161,2162,2163,2164,2165,2166,2167,2168,2169,2210,2211,2212,2215,2216,2217,2220
K
99
1036
DANEK PLATE AND SCREW SYSTEM
K
99
1055
OSTEONICS SPINAL SYSTEM- ROD/ PLATE SYSTEM
K
99
1552
SYNTHES PEDIATRIC ROD SYSTEM
K
99
1528
MODIFICATION TO TENOR SPINAL SYSTEM-ROD/BOLT CONNECTOR
K
99
0721
ISOLOCK SPINAL SYSTEM
K
99
1460
MODIFICATION TO ZPLATE-ATL ANTERIOR FIXATION SYSTEM
K
99
1364
MODIFICATION TO TENOR SPINAL SYSTEM-PLATES
K
99
0657
TRIFIX PEDICLE SPINAL SCREW ASSEMBLY
K
99
0118
ISOBAR SPINAL SYSTEM
K
98
4302
OSTEONICS SPINAL SYSTEM CYLINDRICAL BONE SCREWS
K
98
3152
OSTEONICS SPINAL SYSTEM 5.5MM & 10.0MM BONE SCREWS
K
98
0761
SYNTHES SPINE PEDIATRIC ROD SYSTEM
K
98
1714
TIMX LOW BACK SYSTEM TITANIUM MX ROD BASED LOW BACK SYSTEM
K
98
1113
PEDIATRIC PRC
K
98
0862
TITANIUM SPINAL ROD SYSTEM
K
98
0852
GII SPINAL FIXATION SYSTEM
K
98
1274
ACROMED TIMX PLATE BASED LOW BACK SYSTEM
K
98
0496
WRIGHT MEDICAL TECHNOLOGY ROD-TO-ROD COUPLER
K
98
0447
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM
K
97
3687
SPINAL CONCEPTS, INC., BACFIX TI SPINAL FIXATION SYSTEM
K
97
4749
SYNERGY CLOSED VARIABLE LOCKING SCREW (VLS), PART OF THE CROSS MEDICAL-SYNERGY ANTERIOR AND POSTERIOR SPINAL SYSTEMS
K
97
4734
AURORA TITANIUM SPINAL ROD SYSTEM
K
97
3836
SYNERGY 6.35MM SS ROD WITH SCREWS FOR ANTERIOR USE, PART OF THE CROSS MEDICAL-SYNERGY ANTERIOR SPINAL SYSTEM
K
97
3425
THE MEHDIAN LUMBO-SACRAL PEDICLE SCREW SYSTEM
K
97
4213
AURORA TITANIUM SPINAL ROD SYSTEM
K
97
3683
OMEGA 21 SYSTEM
K
97
2568
DEPUY MOTECH MOSS-MIAMI SPINAL SYSTEM
K
97
1970
EBI SPINELINK SYSTEM
K
97
0285
AESUCLAP SOCON SPINAL SYSTEM
K
97
0950
EASY ROD
K
96
5102
ACROMED PEDICLE SCREW
K
96
4533
EBI SPINELINK SYSTEM
K
96
5046
ISOLA TWISTER CONNECTOR
K
96
3045
SYNTHES (U.S.A.) UNIVERSAL SACRAL SYSTEM
K
96
4544
OSTEONICS SPINAL SYSTEM - VARIABLE OFFSET CONNECTOR ASSEMBLY
K
96
4304
OSTEONICS SPINAL SYSTEM-TOPLOADING TRANSVERSE CONNECTOR ASSEMBLY
K
95
0099
SYNERGY(TM) TI POSTERIOR SPINAL SYSTEM
K
96
3357
MODIFICATION TO THE SYNTHES (USA) UNIVERSAL SPINAL HOOK, ROD, AND AND SACRAL SCREW FIXATION SYSTEM IN 316L STAINLESS STE
K
96
4007
ACROMED CABLE/WIRE PEDICLE SCREW
K
96
2608
SYNTHES (U.S.A.) UNIVERSAL SPINAL PARALLEL CONNECTOR
K
96
2645
ISOLA TWISTER CONNECTOR
K
96
2784
ULTIUM SPINAL PLATING SYSTEM
K
96
2757
J.B.S. SPINE SYSTEM WITH PEDICLE SCREWS - ADDITIONAL COMPONENTS - SCREWS, LINKING PLATES, HOOKS AND ROD CLAMP
K
96
1572
VERSALOK SCREW ASSEMBLY (PROPOSED NAME)
K
96
0107
DDS SPINAL SYSTEM
K
96
0451
WEBB-MORLEY SPINE SYSTEM
K
95
3881
SPINE SYSTEM SACRAL PLATE
K
95
3915
MOSS MIAMI SPINAL SYSTEM (ANTERIOR USE)
K
95
0717
AUGMENT-T POSTERIOR SPINAL SYSTEM
K
94
3827
SPINE FIXATION
K
95
0999
KSF POSTERIOR SPINGAL FIXATOR FOR SEVERE SPONDYLOLISTHESIS
K
95
2236
ISOLA SYSTEM
K
95
2298
SPINAL PEDICLE SCREW, FIXATION, APPLIANCE
K
95
1266
AMSET R-F SYSTEM
K
95
3779
SADDLE WITH ANCHOR, STAINLESS STEEL VARIFIX SYSTEM
K
95
3778
SADDLE WITH ANCHOR, TITANIUM VARIFIX SYSTEM
K
95
3635
TITANIUM DYNA-LOK SPINAL SYSTEM
K
95
3416
BRYAN POSTERIOR SPINAL FIXATOR (BPSF)
K
95
3369
STAINLESS STEEL VARIFIX SYSTEM 5.0MM DIAMETER ANCHOR SCREW
K
95
1725
OSTEONICS SPINAL SYSTEM
K
95
0865
ROGOZINSKI SPINAL ROD SYSTEM ROD-TO-BOLT (UNIVERSAL) CONNECTOR FOR USE WITH THE SIMMONS PLATING SYSTEM BOLT
K
95
0596
GDLH POSTERIOR SPINAL SYSTEM
K
95
0955
PARAGON POSTERIOR SPINAL SYSTEM
K
95
1657
VSP (VARIABLE SCREW PLACEMENT) SPINAL FIXATION SYSTEM, PEDICLE SCREW(S), SPINE PLATE(S), WASHER(S) & NUT(S)
K
95
1626
SYNTHES (U.S.A.) UNIVERSAL SPINAL HOOK, ROD AND PEDICLE/SACRAL SCREW FIXATION SYSTEM
K
95
1794
SYNTHES (USA) UNIV. SCREW FIXATION SYSTEM (TITANIUM)
K
93
6307
DYNA-LOK ANTERIOR PLATING SYSTEM
K
95
1116
ACROMED PEDICLE SCREW
K
95
0074
WRIGHT-LOC(TM) SPINAL FIXATION SYSTEM
K
94
6348
TITANIUM TSRH(R) SPINAL SYSTEM (SCREWS)
K
95
1308
5.8MM DIAMETER ANCHOR SCREW
K
95
1172
TITANIUM LOW PROFILE CROSS BAR
K
95
0695
DEPUY MOTECH MOSS SPINAL SYSTEM - PEDICLE FIXATION
K
94
0631
CROSS MEDICAL - SYNERGY(TM) SPINE SYSTEM
K
95
0697
DEPUY MOTECH MOSS MIAMI SPINAL SYSTEM - PEDICLE FIXATION
K
94
4737
ISOLA SPINE SYSTEM
K
93
0353
SIMMONS PLATING SYSTEM BOLT AND SCREW
K
93
0298
ROGOZINSKI SPINAL ROD SYSTEM SCREW
K
94
4756
ISOLA OPEN AND CLOSED SCREWS
K
94
4736
VSP (VARIABLE SCREW PLACEMENT)
K
94
5064
SELBY INSTRUMENTATION
K
94
3775
SELBY INSTRUMENTATION
K
94
2387
SELBY INSTRUMENTATION
K
93
2029
TSRH SPINAL SCREWS
MNI
Orthosis, Spinal Pedicle Fixation
MNU
Staple, Absorbable
MQP
Spinal Vertebral Body Replacement Device
MQV
Filler, Bone Void, Calcium Compound
MRY
Appliances And Accessories, Fixation, Bone, Absorbable Single/Multiple Component
NDD
Cerclage, Fixation, Metallic
NDE
Rod, Fixation, Intramedullary And Accessories, Metallic And Non-Collapsible
NDF
Plate, Fixation, Bone, Non-Spinal, Metallic
NDG
Washer, Bolt, Nut, Non-Spinal, Metallic
NDJ
Screw, Fixation, Bone, Non-Spinal, Metallic
NDK
System, External Fixator (With Metallic Invasive Components)
NDL
Pin, Fixation, Smooth, Metallic
NDM
Pin, Fixation, Threaded, Metallic
NDN
Cement, Bone, Vertebroplasty
NJA
Accessory, System, External Fixator, Containing Antimicrobial Agent
NJD
Prosthesis, Knee, Femorotibial, Unicompartmental/Unicondylar, Uncemented, Porous-Coated, Metal/Polymer
NKB
Thoracolumbosacral Pedicle Screw System
NKG
Posterior Cervical Screw System
NOV
Anchor, Suture, Bone Fixation, Metallic
NPJ
Prosthesis, Knee Patellofemorotibial, Partial, Semi-Constrained, Cemented, Polymer/Metal/Polymer
NQP
Posterior Metal/Polymer Spinal System, Fusion
NQW
Orthosis, Spine, Plate, Laminoplasty, Metal
NUD
Vertebroplasty Compound, Calcium Based
NVC
Bone, Heterograft
NWN
Laparoscopic Bone Anchor Urethropexy Instrument Kit
OBL
Cement, Bone, Pre-Formed, Modular, Polymeric, Vertebroplasty
OBM
Cement, Bone, Vertebroplasty, Pre-Formed, Modular
OBT
Plate, Bone, Growth Control, Pediatric, Epiphysiodesis
OCG
Prosthesis, Hip, Pelvifemoral Resurfacing, Metal/Polymer, Uncemented
ODP
Intervertebral Fusion Device With Bone Graft, Cervical
OIS
Calcium Salt Bone Void Filler, Drillable, Non-Screw Augmentation
OIY
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Cemented, Polymer + Additive/Metal/Polymer + Additive
OJB
Resorbable Spinal Intervertebral Body Fixation Orthosis - Plate
OJM
Resorbable Spinal Intervertebral Body Fixation Orthosis - Mesh
OOG
Knee Arthroplasty Implantation System
OOL
Electronic Depth Gauge
OQB
Intervertebral Body Graft Containment Device
OQG
Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
OQH
Hip, Semi-Constrained, Cemented, Metal/Polymer + Additive, Cemented
OQI
Hip, Semi-Constrained, Cemented, Metal/Ceramic/Polymer + Additive, Porous Uncemented
OSH
Pedicle Screw Spinal System, Adolescent Idiopathic Scoliosis
OSN
Software For Diagnosis/Treatment
OUR
Sacroiliac Joint Fixation
OVD
Intervertebral Fusion Device With Integrated Fixation, Lumbar
OVE
Intervertebral Fusion Device With Integrated Fixation, Cervical
OVZ
Pin, Fixation, Resorbable, Hard Tissue
OWI
Bone Fixation Cerclage, Sublaminar
OYK
Ankle Arthroplasty Implantation System
OZI
Internal Hinged Elbow Fixator
PAO
Prosthesis, Shoulder, Semi-Constrained, Metal/Polymer + Additive, Cemented
PBF
Orthopaedic Surgical Planning And Instrument Guides
PBI
Prosthesis, Hip, Constrained, Cemented Or Uncemented, Metal/Polymer, + Additive
PEK
Spinous Process Plate
PHM
Intervertebral Fusion Device With Bone Graft, Thoracic
PHQ
Anterior Staple As Supplemental Fixation For Fusion
PHX
Shoulder Prosthesis, Reverse Configuration
PKC
Prosthesis, Total Anatomic Shoulder, Uncemented Metaphyseal Humeral Stem With No Diaphyseal Incursion, Semi-Constrained
PLF
Bone Wedge
PLR
Spinal Vertebral Body Replacement Device - Cervical
PLW
Acetabular Cup Orientation System
PML
Bone Cement, Posterior Screw Augmentation
PPQ
Transtibial Anterior Cruciate Ligament Kit
QHQ
Total Shoulder Arthroplasty System
PQC
Pedicle Screw Placement Guide
QAC
Screw Sleeve Bone Fixation Device
QAD
Rod, Fixation, Intramedullary And Accessories, In-Vivo Cured, Light-Activated
QFP
Intraoperative Orthopedic Strain Sensor
QHE
Shoulder Arthroplasty Implantation System
QNI
Resorbable Implant For Anterior Cruciate Ligament (Acl) Repair
QPP
Implantable Post-Surgical Kinematic Measurement Knee Device
QPQ
Shoulder Spacer For Massive Irreparable Rotator Cuff Tear, Resorbable, Inflatable, Non-Fixed
JDJ
Mesh, Surgical, Acetabular, Hip, Prosthesis
JDK
Prosthesis, Hip, Cement Restrictor
LZN
Cement Obturator
OLC
Scaffold, Partial Medial Meniscal Defects Extending Into The Red/White Zone, Resorbable Bovine Collagen
QSD
Posterior Cervical Screw Placement Guide
QSR
Sacroiliac Screw Placement Guide
QVI
Screw Sleeve Bone Fixation Device, Spine
QUW
Mesh, Surgical, Non-Resorbable, Orthopedics, Reinforcement Of Ligament
QWJ
Mesh, Surgical, Polymeric, Resorbable, Orthopedics, Reinforcement Of Ligament
SAI
Ankle Fusion Cage
SCY
Sacroiliac Joint Guidewire Placement Device
Subpart E—Neurological Surgical Devices
Subpart E—Surgical Devices
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OR
/
subpart-d—prosthetic-devices
/
MNH
/
K061813
View Source
MANTIS SPINAL SYSTEM
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K061813
510(k) Type
Traditional
Applicant
Stryker Spine
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
9/19/2006
Days to Decision
84 days
Submission Type
Summary