K961228 · KARL STORZ Endoscopy-America, Inc. · HRX · Oct 10, 1996 · Orthopedic
Device Facts
Record ID
K961228
Device Name
KARL STORZ MAGNIFYING ARTHROSOCPES
Applicant
KARL STORZ Endoscopy-America, Inc.
Product Code
HRX · Orthopedic
Decision Date
Oct 10, 1996
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.1100
Device Class
Class 2
Intended Use
The KSEA magnifying arthroscopes and accessories are intended for use by qualified surgeons during arthroscopic procedures of the small and large joints. Specific arthroscope models are intended for arthroscopic procedures of the shoulder and knee; arthroscopic procedures of the elbow, ankle, wrist and jaw; and arthroscopic procedures for the shoulder, knee and illumination and visualization of the hip joint to diagnose disease and for the removal of loose bodies in the hip joint”.
Device Story
Manually operated, reusable rigid arthroscope; features integrated ring for image magnification adjustment. Used by surgeons in clinical/OR settings for joint visualization. Provides optical access to surgical sites; aids diagnosis and loose body removal. Stainless steel construction. No electronic or automated processing.
Indicated for qualified surgeons performing arthroscopic procedures in small and large joints, including shoulder, knee, elbow, ankle, wrist, and jaw, for disease diagnosis and removal of loose bodies in the hip joint.
Regulatory Classification
Identification
An arthroscope is an electrically powered endoscope intended to make visible the interior of a joint. The arthroscope and accessories also is intended to perform surgery within a joint.
Related Devices
K023783 — SOHNIKS · Sohniks Endoscopy, Inc. · Feb 7, 2003
K960805 — ARTHOSCOPE · United States Surgical, A Division of Tyco Healthc · Apr 10, 1996
K963524 — KSEA LARGE JOINT ARTHROSCOPY SET · Karl Storz Endoscopy · Nov 14, 1996
K030096 — VIDEO ARTHROSCOPE, MODELS AR-3050-30, AR-3050T-30, AR-3050-70, AR-3051-30, AR-3052-30, AR3030AN, AR-3030AS, AR3030AW · Arthrex, Inc. · Mar 18, 2003
Submission Summary (Full Text)
{0}
STORZ
Karl Storz Endoscopy
Karl Storz
Endoscopy-America, Inc.
600 Corporate Pointe
Culver City, California 90230-7600
Phone 310 558 1500
Toll Free 800 421 0837
Fax 310 410 5527
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS
*K961778*
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of the Safe Medical Devices Act (SMDA) of 1990 and 21 CFR 807.92. All data included in this document are accurate and complete to the best of KSEA’s knowledge.
**Applicant:**
Karl Storz Endoscopy - America, Inc.
600 Corporate Pointe
Culver City, CA 90230
(310) 558-1500
**OCT 10 1996**
**Contact:**
Marika Anderson
Senior Regulatory Affairs Specialist
**Device Identification:**
Common Name
Arthroscope
Trade Name
Karl Storz Magnifying Arthroscope
**Indication:** The KSEA magnifying arthroscopes and accessories are intended for use by qualified surgeons during arthroscopic procedures of the small and large joints. Specific arthroscope models are intended for arthroscopic procedures of the shoulder and knee; arthroscopic procedures of the elbow, ankle, wrist and jaw; and arthroscopic procedures for the shoulder, knee and illumination and visualization of the hip joint to diagnose disease and for the removal of loose bodies in the hip joint”.
**Device Description:** The KSEA magnifying arthroscopes are manually operated, reusable surgical devices consisting of a rigid arthroscope with a ring for adjusting the magnification of the image. The arthroscopes are long enough to gain access to the surgical site. The body contact materials are surgical grade stainless steel.
**Substantial Equivalence:** The KSEA magnifying arthroscopes and accessories are substantially equivalent to the predicate devices since the basic features, design and intended uses are the same. The minor differences in design and dimensions between the KSEA magnifying arthroscopes and the predicate devices raise no new issues of safety and effectiveness, as these design differences have no effect on the performance, function or intended use of these devices.
Signed:
*Marika Anderson*
Senior Regulatory Affairs Specialist
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.