Injection Data Capture Device

Page Type
Product Code
Definition
An injection data capture device is an electrically-powered/electromechanical accessory that interfaces with reusable or disposable injection devices for the purposes of interpreting, recording and displaying and/or transmitting injection data to a connected application or software.
Physical State
An injection data capture device may consist of an attachable add-on device that a user attaches to the injection device or could be manufactured directly into the injection device. The device may be single or multi-component and includes electromechanical hardware and software to allow for the detection, transmission and/or display of injection data.
Technical Method
Injection data capture devices are operated manually or automatically to detect injections and record injection data. This can include the ability to detect the amount of dose dialed/administered, detect day/time of dose, or other injection data (e.g., detect prime/no-prime events). This data can be displayed on the injection data capture device directly and/or transmitted to a connected software or mobile application via wired or wireless methods.
Target Area
Injection data capture devices do not have a target area but are instead intended to interface with injection devices.
Regulation Medical Specialty
General Hospital
Review Panel
General Hospital
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
880.5860
GMP Exempt?
No
Summary Malfunction Reporting
Ineligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 880.5860 Piston syringe

§ 880.5860 Piston syringe.

(a) Identification. A piston syringe is a device intended for medical purposes that consists of a calibrated hollow barrel and a movable plunger. At one end of the barrel there is a male connector (nozzle) for fitting the female connector (hub) of a hypodermic single lumen needle. The device is used to inject fluids into, or withdraw fluids from, the body.

(b) Classification. Class II (performance standards).

Injection Data Capture Device

Page Type
Product Code
Definition
An injection data capture device is an electrically-powered/electromechanical accessory that interfaces with reusable or disposable injection devices for the purposes of interpreting, recording and displaying and/or transmitting injection data to a connected application or software.
Physical State
An injection data capture device may consist of an attachable add-on device that a user attaches to the injection device or could be manufactured directly into the injection device. The device may be single or multi-component and includes electromechanical hardware and software to allow for the detection, transmission and/or display of injection data.
Technical Method
Injection data capture devices are operated manually or automatically to detect injections and record injection data. This can include the ability to detect the amount of dose dialed/administered, detect day/time of dose, or other injection data (e.g., detect prime/no-prime events). This data can be displayed on the injection data capture device directly and/or transmitted to a connected software or mobile application via wired or wireless methods.
Target Area
Injection data capture devices do not have a target area but are instead intended to interface with injection devices.
Regulation Medical Specialty
General Hospital
Review Panel
General Hospital
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
880.5860
GMP Exempt?
No
Summary Malfunction Reporting
Ineligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 880.5860 Piston syringe

§ 880.5860 Piston syringe.

(a) Identification. A piston syringe is a device intended for medical purposes that consists of a calibrated hollow barrel and a movable plunger. At one end of the barrel there is a male connector (nozzle) for fitting the female connector (hub) of a hypodermic single lumen needle. The device is used to inject fluids into, or withdraw fluids from, the body.

(b) Classification. Class II (performance standards).