FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart B—Physical Medicine Diagnostic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
DZS
Capsule, Dental, Amalgam
1
Product Code
DYH
Adhesive, Bracket And Tooth Conditioner, Resin
2
Product Code
DZE
Implant, Endosseous, Root-Form
2
Product Code
EBC
Sealant, Pit And Fissure, And Conditioner
2
Product Code
EBD
Coating, Filling Material, Resin
2
Product Code
EBE
Coating, Denture Hydrophilic, Resin
2
Product Code
EBF
Material, Tooth Shade, Resin
2
Product Code
EBG
Crown And Bridge, Temporary, Resin
2
Product Code
EBH
Material, Impression Tray, Resin
1
Product Code
EBI
Resin, Denture, Relining, Repairing, Rebasing
2
Product Code
EBL
Pin, Retentive And Splinting, And Accessory Instruments
1
Product Code
EBO
Denture Repair Kit
2
Product Code
EBP
Reliner, Denture, Over The Counter
2
Product Code
EFD
Amalgamator, Dental, Ac-Powered
1
Product Code
EFT
Cleanser, Denture, Over The Counter
1
Product Code
EGG
Attachment, Precision, All
1
Product Code
EHE
Dispenser, Mercury And/Or Alloy
1
Product Code
EHO
Bar, Preformed
1
Product Code
EHP
Clasp, Preformed
1
Product Code
EHQ
Cusp, Preformed
1
Product Code
EHR
Pad, Denture, Over The Counter
2
Product Code
EHS
Cushion, Denture, Over The Counter
2
Product Code
EIT
Applicator, Rapid Wax, Dental
2
Product Code
EJH
Alloy, Metal, Base
2
Product Code
EJJ
Alloy, Amalgam
2
Product Code
EJK
Liner, Cavity, Calcium Hydroxide
2
Product Code
EJL
Bur, Dental
1
Product Code
EJP
Articulators
1
Product Code
EJS
Alloy, Other Noble Metal
2
Product Code
EJT
Alloy, Gold-Based Noble Metal
2
Product Code
EJW
Clasp, Wire
1
Product Code
EJX
Anchor, Preformed
1
Product Code
EKL
Point, Silver, Endodontic
1
Product Code
EKM
Gutta-Percha
1
Product Code
EKN
Point, Paper, Endodontic
1
Product Code
EKO
Denture Preformed (Partially Prefabricated Denture)
2
Product Code
ELE
Implant, Subperiosteal
2
Product Code
ELJ
Teeth, Artificial, Posterior With Metal Insert
1
Product Code
ELK
Teeth, Artificial, Backing And Facing
1
Product Code
ELL
Teeth, Porcelain
2
Product Code
ELM
Denture, Plastic, Teeth
2
Product Code
ELN
Teeth, Preformed Gold Denture
1
Product Code
ELO
Cusp, Gold And Stainless Steel
1
Product Code
ELR
Post, Root Canal
1
Product Code
ELS
Splint, Endodontic Stabilizing
2
Product Code
ELW
Material, Impression
2
Product Code
K
25
3501
Hydro Print Premium Fast Set - 454g (1lb) (052037); Hydro Print Premium Regular Set - 454g (1lb) (052327); Chroma Print Premium Fast Set - 454g (1lb) (052457); Chroma Print Premium Regular Set - 454g (1lb) (051460); Perfil Pro - 454g (1lb) (056213); Perfil Pro+ - 454g (1lb) (056121); Perfil Pro Chroma - 454g (1lb) (056122); Hydro Print Premium Fast Set - Multi Pack (056205); Hydro Print Premium Regular Set - Multi Pack (056208); Hydro Print Premium Fast Set - 9,07Kg (20lb) (056204);
2
Cleared 510(K)
K
25
0969
JET BITE; JET BLUE BITE FAST; JET BLUE BITE SUPERFAST
2
Cleared 510(K)
K
24
1924
Elastic Impression Material
2
Cleared 510(K)
K
24
2360
Speedex Light Body; Speedex Medium; Speedex Putty; Speedex Putty Soft; Speedex Universal Activator
2
Cleared 510(K)
K
23
3954
Chemi-SiL (HB, MB, LB, LBS); Chemi-SiL Bite-Blu
2
Cleared 510(K)
K
22
3892
DentMix VPS Impression Material
2
Cleared 510(K)
K
21
3175
No Stress Impress
2
Cleared 510(K)
K
21
4086
Bright Impress-Light, Bright Impress-Medium, Bright Impress-Heavy, Bright Impress-Bite, Bright Impress-Putty
2
Cleared 510(K)
K
22
2741
DENU Light Body(Regular, Fast), DENU Heavy Body(Regular, Fast), DENU Putty Set(Regular, Fast)
2
Cleared 510(K)
K
21
3244
Accusil Dental Impression Materials (Accusil Light Body Regular and Fast Set, Accusil Heavy Body Regular and Fast Set, Accusil Monophase Regular and Fast Set, Accusil Putty Regular and Fast Set, Accusil Bite Registration)
2
Cleared 510(K)
K
22
1668
Dental Impression Material
2
Cleared 510(K)
K
21
3890
IMICRYL Impression Materials
2
Cleared 510(K)
K
22
0257
Permadyne
2
Cleared 510(K)
K
22
0097
PRESIDENT The Original
2
Cleared 510(K)
K
21
1489
Dental Impression Material
2
Cleared 510(K)
K
20
3824
VPS Impression Material
2
Cleared 510(K)
K
21
0041
HySil Plus Impression Materials
2
Cleared 510(K)
K
20
1483
Impression Material
2
Cleared 510(K)
K
20
1684
A-Silicone for Bite Registration
2
Cleared 510(K)
K
20
1184
Lascod Impression Materials
2
Cleared 510(K)
K
19
2941
HySil Super Fast Impression Materials
2
Cleared 510(K)
K
19
0571
StoneBite and StoneBite scan
2
Cleared 510(K)
K
19
1034
VPS Impression Material
2
Cleared 510(K)
K
18
1604
Sildent Fast Light Body, Sildent Fast Heavy Body, Sildent Bite
2
Cleared 510(K)
K
18
1236
HySil Impression Materials
2
Cleared 510(K)
K
18
1011
AIM2
2
Cleared 510(K)
K
18
0565
PEAK NS033CF, PEAK NS017CF
2
Cleared 510(K)
K
17
1562
Dynax clear, Dynax putty, Dynax heavy body, Dynax light, Dynax mono
2
Cleared 510(K)
K
17
3318
Rapid HB, Rapid LB, Rapid MB
2
Cleared 510(K)
K
17
0812
HygePLUS Alginate Impression Material
2
Cleared 510(K)
K
17
0736
HySil Impression Materials
2
Cleared 510(K)
K
15
2615
Vonflex S
2
Cleared 510(K)
K
16
1774
i-Sil
2
Cleared 510(K)
K
16
0097
Image Fast Set, Image Regular Set
2
Cleared 510(K)
K
16
0441
Identic and KromaFaze Alginate Dental Impression Materials
2
Cleared 510(K)
K
15
2826
NoCord
2
Cleared 510(K)
K
15
2766
CharmFlex
2
Cleared 510(K)
K
15
2861
Aquasil Ultra + Smart Wetting Impression Material
2
Cleared 510(K)
K
15
2518
Vonflex S Putty
2
Cleared 510(K)
K
15
2349
Star+ VPS Scannable Impression Material
2
Cleared 510(K)
K
15
1535
Cavex Cream Alginate
2
Cleared 510(K)
K
15
2180
PEAK
2
Cleared 510(K)
K
15
1262
Hyflex Heavy, Hyflex Mono, Hyflex Light
2
Cleared 510(K)
K
15
1150
Elements
2
Cleared 510(K)
K
14
3575
Accu-Dent XD Tray, Accu-Dent XD Syringe
2
Cleared 510(K)
K
14
3382
DentiAnn Smart Sil
2
Cleared 510(K)
K
14
1092
MARK3
2
Cleared 510(K)
K
14
0966
VONFLEX S BITE
2
Cleared 510(K)
K
13
2869
SILDENT
2
Cleared 510(K)
K
14
0602
FLASH PENTA MB QUICK, FLASH MB QUICK
2
Cleared 510(K)
K
13
3071
ELASTIC IMPRESSION MATERIAL
2
Cleared 510(K)
K
14
0074
HYGEDENT ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
13
4008
MD-FLEX HEAVY BODY
2
Cleared 510(K)
K
13
3527
SUFLEX PUTTY, SUFLEX HEAVY, SUFLEX MONO, SUFLEX LIGHT
2
Cleared 510(K)
K
13
3436
FLASH AR; FLASH AR QUICK
2
Cleared 510(K)
K
13
3400
FLASH BITE
2
Cleared 510(K)
K
13
2599
SMILEBOND SYSTEM
2
Cleared 510(K)
K
13
1510
POLYDIMETHYLSILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
13
0920
CORRECT PLUS 1
2
Cleared 510(K)
K
13
1404
FLASH AR PENTA / FLASH AR PENTA QUICK
2
Cleared 510(K)
K
13
0869
TAKE 1 ADVANCE
2
Cleared 510(K)
K
13
0647
XANTASIL DYNAMIX FAST SET CARTRIDGE -2 X 380ML; XANTASIL FAST SET CARTRIDGE -6 X 50ML
2
Cleared 510(K)
K
12
1824
ALGINOR ALGINELLE TYPE 1 AND 2 MILLENIUM KROMOPAN 1 AND 2
2
Cleared 510(K)
K
12
0914
FLEXITIME FAST & SCAN LIGHT FLOW
2
Cleared 510(K)
K
11
3574
FLEXITIME MONOPHASE PRO SCAN
2
Cleared 510(K)
K
12
0013
TEMPSPAN CLEAR MATRIX
2
Cleared 510(K)
K
12
0521
GC BLUE SILICONE
2
Cleared 510(K)
K
12
0438
FLASH (DIFFERENT MATERIALS)
2
Cleared 510(K)
K
11
3406
AQUASIL ULTRA SMART WETTING IMPRESSION MATERIAL
2
Cleared 510(K)
K
11
3279
IDENTIUM HEAVY, IDENTIUM MEDIUM, IDENTIUM SCAN HEAVY, IDENTIUM SCAN MEDIUM, IDENTIUM SCAN LIGHT
2
Cleared 510(K)
K
11
3263
ARGES IMAGING CONTRAST SPRAY
2
Cleared 510(K)
K
11
0871
FIT CHECKER ADVANCED
2
Cleared 510(K)
K
11
0092
TAKE 1 ADVANCED RIGID TRAY
2
Cleared 510(K)
K
11
0378
IMPRESSION COMPOUND
2
Cleared 510(K)
K
10
3586
IOS FASTSCAN SPRAY
2
Cleared 510(K)
K
11
0050
FIT TEST C&B
2
Cleared 510(K)
K
10
3346
DELIKIT PUTTY, DELIKIT HEAVY BODY, DELIKIT LIGHT BODY
2
Cleared 510(K)
K
10
2836
BONASIL A+ IMPRESSION MATERIALS
2
Cleared 510(K)
K
10
2770
FLEXTIME FAST & SCAN PUTTY, FLEXTIME FAST & SCAN LIGHT FLOW, FLEXTIME FAST & SCAN MEDIUM FLOW
2
Cleared 510(K)
K
10
2739
HYDROCOLOR 5
2
Cleared 510(K)
K
10
3164
VONFLEX HEAVY, VINFLEX LIGHT
2
Cleared 510(K)
K
10
1617
FLEXITIME XTREME 2 HEAVY TRAY CARTRIDGE REFILL, FEXITIME XTREME 2 LIGHT TRAY CARTRIDGE REFILL
2
Cleared 510(K)
K
09
2176
TAKE 1 ADVANCED RIGID TRAY
2
Cleared 510(K)
K
09
1613
TAKE 1
2
Cleared 510(K)
K
09
2867
IDENTIUM HEAVY, MEDIUM, MEDIUM SOFT, LIGHT
2
Cleared 510(K)
K
09
2319
STAR VPS, MODEL 80014-01, FIRST QUATER, MODEL 90649, FIRST HALF, MODEL 89387
2
Cleared 510(K)
K
09
1494
FLEXITIME FLOW
2
Cleared 510(K)
K
09
1267
VONFLEX PUTTY
2
Cleared 510(K)
K
08
3739
HYDRORISE AND HYDROSYSTEM
2
Cleared 510(K)
K
08
3701
PANASIL INITIAL CONTACT AND PANASIL TRAY
2
Cleared 510(K)
K
08
2591
FLEXITIME BITE
2
Cleared 510(K)
K
08
2560
PANASIL IMPRESSION MATERIALS, INCLUDING PUTTY, BINETICS, TRAY, MONOPHASE AND CONTACT
2
Cleared 510(K)
K
08
2157
KETTOSIL AND SILGINAT
2
Cleared 510(K)
K
08
1017
TEMPLATE AND COUNTER-FIT
2
Cleared 510(K)
K
08
1084
COLORISE RIGID
2
Cleared 510(K)
K
08
1120
FUTAR (FUTAR, FUTAR D, FUTAR D FAST, FUTAR D SLOW, FUTAR SCAN BITE REGISTRATION MATERIALS
2
Cleared 510(K)
K
08
0338
CUTTERSIL ACTIVATOR UNIVERSAL PLUS
2
Cleared 510(K)
K
08
0882
CEREC OPTI SPRAY
2
Cleared 510(K)
K
08
0514
PECD-01 AND PECD QUICK-01
2
Cleared 510(K)
K
08
0130
OCCLUFAST CAD
2
Cleared 510(K)
K
07
3475
SYSTEM PLUS
2
Cleared 510(K)
K
07
3005
ELITE GLASS
2
Cleared 510(K)
K
07
2577
BISICO IMPRESSION SILICONES & ALGINATES
2
Cleared 510(K)
K
07
2622
STANDOUT 2
2
Cleared 510(K)
K
07
2245
EMULATE ADVANCED
2
Cleared 510(K)
K
07
1192
BLUGOO HD
2
Cleared 510(K)
K
07
0677
COLORISE
2
Cleared 510(K)
K
07
0700
FREEALGIN
2
Cleared 510(K)
K
06
2400
IMPRESSIX, COLORCHANGE ALGINATE
2
Cleared 510(K)
K
06
0891
VIRTUAL
2
Cleared 510(K)
K
06
1267
SIMULATE, COLOR CHANGE ALGINATE
2
Cleared 510(K)
K
06
1427
PRE-IMPRESSION CONDITIONING SOLUTION
2
Cleared 510(K)
K
05
3619
COLORBITE
2
Cleared 510(K)
K
05
3427
FRESH, DENTAL IMPRESSION MATERIAL
2
Cleared 510(K)
K
05
1933
EXPASYL POWER APPLICATOR
2
Cleared 510(K)
K
05
2455
IMPRESSIX
2
Cleared 510(K)
K
05
3014
POLY SILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
05
3018
POLY SILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
05
2409
SILGIMIX ALGINATE REPLACEMENT IMPRESSION MATERIAL
2
Cleared 510(K)
K
05
2090
SPLASH! IMPRESSION MATERIAL DEVICE
2
Cleared 510(K)
K
05
1797
FUTURE WASH/YPS
2
Cleared 510(K)
K
05
0417
ELITE IMPLANT
2
Cleared 510(K)
K
05
1424
HYDROGUM 5
2
Cleared 510(K)
K
05
1535
MODIFICATION TO:REGISTRADO X-TRA
2
Cleared 510(K)
K
05
1243
JET BLUE BITE
2
Cleared 510(K)
K
05
1207
CAVEX ORTHOTRACE
2
Cleared 510(K)
K
05
0604
KERR VPS IMPRESSION MATERIAL
2
Cleared 510(K)
K
04
3493
FUSION PUTTY TYPE
2
Cleared 510(K)
K
04
3054
GENIE MAGIC MIX ULTRA HYDROPHILIC IMPRESSION MATERIAL
2
Cleared 510(K)
K
05
0013
RETRACTOFOAM
2
Cleared 510(K)
K
04
3471
FUSION FAST
2
Cleared 510(K)
K
04
3118
HYDROGUM SOFT
2
Cleared 510(K)
K
04
2878
FLEXITIME XTREME
2
Cleared 510(K)
K
04
3131
TORPICALGIN
2
Cleared 510(K)
K
04
2860
CORRECT DENTAL IMPRESSION MATERIAL
2
Cleared 510(K)
K
04
1398
GC FUSION
2
Cleared 510(K)
K
04
1229
MULTIPLE (ADDITION SILICONE IMPRESSION MATERIAL)
2
Cleared 510(K)
K
04
1028
CROWN DELTA HYDROPHILIC IMPRESSION MATERIAL
2
Cleared 510(K)
K
04
0053
PRECISION VPS IMPRESSION MATERIAL
2
Cleared 510(K)
K
03
2708
PLASTALGIN AND PLASTALGIN ORTHO
2
Cleared 510(K)
K
03
2289
FIT CHECKER II
2
Cleared 510(K)
K
03
1439
ALGINATE IMPRESSION MATERIAL III (FAST & REGULAR)
2
Cleared 510(K)
K
03
2116
TULIP COLORSWITCH
2
Cleared 510(K)
K
03
2001
POLY Q (GARANT L, PENTA M, PENTA H)
2
Cleared 510(K)
K
03
1484
STAND OUT
2
Cleared 510(K)
K
03
0776
MEGA BITE REGISTRATION - DENTAL BITE REGISTRATION MATERIAL
2
Cleared 510(K)
K
03
0414
GENIE ULTRA HYDROPHILIC IMPRESSION MATERIAL
2
Cleared 510(K)
K
03
0318
P2 POLYETHER
2
Cleared 510(K)
K
02
3751
EXAJET
2
Cleared 510(K)
K
02
4041
ZETAPLUS SOFT
2
Cleared 510(K)
K
02
4034
OCCLUFAST ROCK
2
Cleared 510(K)
K
02
3466
TULIP ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
02
2653
ELITE MONOPHASE
2
Cleared 510(K)
K
02
2430
ISO FUNCTIONAL
2
Cleared 510(K)
K
02
2066
REGISTRADO X-TRA
2
Cleared 510(K)
K
02
1416
AQUASIL ULTRA MONOPHASE/HEAVY/LV SMART WETTING IMPRESSION MATERIAL
2
Cleared 510(K)
K
02
1413
AQUASIL ULTRA RIGID SMART WETTING IMPRESSION MATERIAL
2
Cleared 510(K)
K
02
1410
AQUASIL ULTRA XLV SMART WETTING IMPRESSION MATERIAL
2
Cleared 510(K)
K
02
0242
EMULATE FAST SET AND EMULATE REGULAR SET
2
Cleared 510(K)
K
01
3859
RHODIA BITE REGISTRATION MATERIAL
2
Cleared 510(K)
K
01
2767
S & C HYDRO VINYL POLYSILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
01
2517
CEREC3 VITABLOCKS
2
Cleared 510(K)
K
01
3336
XANTALGIN CRONO
2
Cleared 510(K)
K
01
3237
STATUSBLUE
2
Cleared 510(K)
K
01
3236
LUXABITE
2
Cleared 510(K)
K
01
3140
RHODIA HYDROPHILIC DENTAL IMPRESSION MATERIAL
2
Cleared 510(K)
K
01
3129
RHODIA DENTAL PUTTY IMPRESSION MATERIAL
2
Cleared 510(K)
K
01
2405
EXTRUDE MODIFIED
2
Cleared 510(K)
K
01
1785
NOVEL PRINT CYAN ALGINATES
2
Cleared 510(K)
K
01
1452
CAVEX STABISIL
2
Cleared 510(K)
K
01
1419
CAVEX COLORCHANGE
2
Cleared 510(K)
K
01
1450
SILICONE IMPRESSION MATERIAL
2
Cleared 510(K)
K
01
0994
TAKE ONE BITE MODIFIED
2
Cleared 510(K)
K
01
0926
R-SI-LINE METAL-BITE
2
Cleared 510(K)
K
00
3808
TAKE 1
2
Cleared 510(K)
K
00
3650
PERMLASTIC 3
2
Cleared 510(K)
K
00
3930
FLEXTIME MAGNUM 360
2
Cleared 510(K)
K
00
3426
ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
00
1655
PERMLASTIC 2
2
Cleared 510(K)
K
00
1414
KWIKKMODEL
2
Cleared 510(K)
K
00
1876
TAKE 1 BITE
2
Cleared 510(K)
K
00
1218
CORRECT PLUS
2
Cleared 510(K)
K
00
0686
KROM-ALGINATE AND ALGINATE PLUS
2
Cleared 510(K)
K
99
4027
ACTIVATOR PASTE
2
Cleared 510(K)
K
00
0878
HONIGUM
2
Cleared 510(K)
K
00
0629
FLEXTIME
2
Cleared 510(K)
K
00
0595
DIMENSION PENTA L
2
Cleared 510(K)
K
00
0591
DIMENSION PENTA H, DIMENSION PENTA H QUICK
2
Cleared 510(K)
K
00
0588
DIMENSION GARANT L, DIMENSION GARANT L QUICK
2
Cleared 510(K)
K
99
4172
CEREC 3
2
Cleared 510(K)
K
99
4192
IMPREGUM PENTA M MONOSOFT
2
Cleared 510(K)
K
99
4193
IMPREGUM PENTA DUOSOFT
2
Cleared 510(K)
K
99
4190
IMPREGUM GARANT L DUOSOFT
2
Cleared 510(K)
K
99
4077
AROMA FINE (NORMAL AND FAST SET)
2
Cleared 510(K)
K
99
2001
TRAY-LINK
2
Cleared 510(K)
K
99
2895
IMPREGUM F
2
Cleared 510(K)
K
99
2897
IMPREGUM PENTA
2
Cleared 510(K)
K
99
1631
FASTRAY LC
2
Cleared 510(K)
K
99
1489
ALGINATE IMPRESSION MATERIAL I (FAST & REGULAR SET)
2
Cleared 510(K)
K
99
1490
ALGINATE IMPRESSION MATERIAL II (FAST & REGULAR SET)
2
Cleared 510(K)
K
99
1008
DIMENSION BITE
2
Cleared 510(K)
K
99
1425
XANTOPREN COMFORT
2
Cleared 510(K)
K
99
1221
VESTOGUM
2
Cleared 510(K)
K
98
3106
1ST IMPRESSION
2
Cleared 510(K)
K
98
2917
B-SYSTEM SILICONE
2
Cleared 510(K)
K
98
1970
ALGETRAL, CAVEX CHROMATIC, CA 37 SUPERIOR PINK, CA 37 FAST SET, CAVEX RAINBOW, CAVEX IMPRESSIONAL NORMAL SETTING, CAVEXI
2
Cleared 510(K)
K
98
1325
3M M.G. MATERIAL
2
Cleared 510(K)
K
98
0968
LONE STAR IMPRESSION SYSTEMS
2
Cleared 510(K)
K
98
1091
NEOCOLLOID, ORTHOPRINT
2
Cleared 510(K)
K
98
0963
HONIGUM AUTOMIX IMPRESSION MATERIAL (FOIL BAGS) AND HONIGUM QUICK IMPRESSION MATERIAL (CARTRIDGES)
2
Cleared 510(K)
K
98
0965
SPECTRA FORM CHROMATIC ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
97
4894
KROMATICA COLOR CHANGING ALGINATE
2
Cleared 510(K)
K
97
4704
HYDROGUM
2
Cleared 510(K)
K
97
4231
POSITION PENTA, POSITION PENTA QUICK
2
Cleared 510(K)
K
97
3781
AQUASIL EASY MIX PUTTY IMPRESSION MATERIAL
2
Cleared 510(K)
K
97
3782
AQUASIL XLV SMART WETTING IMPRESSION MATERIAL
2
Cleared 510(K)
K
97
3694
PROVIL NOVO
2
Cleared 510(K)
K
97
3343
HYDROFLEX
2
Cleared 510(K)
K
97
2871
GENESIS
2
Cleared 510(K)
K
97
0129
TULIP
2
Cleared 510(K)
K
97
2276
CEREC 2 CROWN SOFTWARE
2
Cleared 510(K)
K
97
2239
ELITE H-D VINYL POLYSILOXANE IMPRESSION MATERIALS .PUTTY SOFT/NORMAL SETTING /PUTTY SOFT/FAST SETTING
2
Cleared 510(K)
K
97
2027
ELITE H-D HYDROPHILIC VINYL POLYSILOXANE IMPRESSION MATERIALS (LIGHT BODY/NORMAL,LIGHT BODY/FAST SETTING,REGULAR BODY,)
2
Cleared 510(K)
K
97
1155
MEMOREG
2
Cleared 510(K)
K
97
0656
HYDROFLEX
2
Cleared 510(K)
K
96
5083
SUPER-DENT ALGINATE,NORMAL SET, FAST SET,SUPER DELUXE DUSTLESS ALGINATE, NORMAL SET, DELUXE DUTLESS ALGINATE, FAST SET
2
Cleared 510(K)
K
97
0594
KALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
97
0433
AQUASIL RIGID SMART WETTING IMPRESSION MATERIAL
2
Cleared 510(K)
K
96
5165
CUTTERSIL COMFORT HARDENER
2
Cleared 510(K)
K
96
5163
CUTTERSIL COMFORT
2
Cleared 510(K)
K
96
4692
PERFECTIM
2
Cleared 510(K)
K
96
4177
KROMALGIN IMPRESSION MATERIAL
2
Cleared 510(K)
K
96
4323
CHROMOPRINT CHROMATIC ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
96
3609
PHASE PLUS
2
Cleared 510(K)
K
96
3766
3M PROPLUS SYSTEM
2
Cleared 510(K)
K
96
3205
ALGINMAX, ORTHOCHROME
2
Cleared 510(K)
K
96
2680
HYUNJAE DENTAL IMPRESSION MATERIALS
2
Cleared 510(K)
K
96
2741
TRI-PHASIX CHROMATIC ALGINATE
2
Cleared 510(K)
K
95
2614
JELTRATE PLUS ANTIMICROBIAL IMPR. MATERIAL
2
Cleared 510(K)
K
95
4281
PANASIL IMPRESSION MATERIAL
2
Cleared 510(K)
K
96
1201
BOSWORTH IMPRESSION MATERIAL II
2
Cleared 510(K)
K
96
0547
DIMENSION PENTA/DIMENSION GARANT L/POLYVINYL SILOXANE ADHESIVE
2
Cleared 510(K)
K
95
5932
EXAFLEX IMPRESSION MATERIAL (MODIFICATION)
2
Cleared 510(K)
K
95
5892
HYDROCOLLOID TRAY MATERIALS, MED. TO HIGH VISCOSITY/WASH MATERIALS, LOW VISCOSITY
2
Cleared 510(K)
K
96
0063
BOSWORTH IMPRESSION MATERIAL I
2
Cleared 510(K)
K
95
5465
DEGUPRINT
2
Cleared 510(K)
K
95
5406
SCAN WHITE 12 ML
2
Cleared 510(K)
K
95
4192
IMPREGUM PENTA
2
Cleared 510(K)
K
95
4180
MICROGLISS
2
Cleared 510(K)
K
95
4662
THERMALASTIC/TRIPOLYVINALENE
2
Cleared 510(K)
K
93
5892
INDURENT GEL
2
Cleared 510(K)
K
95
4223
AMERICAN DENTAL PRODUCTS ALGINATE FLAVORING
2
Cleared 510(K)
K
95
2728
RETRAC
2
Cleared 510(K)
K
95
2930
DENTRAY II PLUS TRAY ADHESIVE
2
Cleared 510(K)
K
93
5890
ZETAPLUS (PUTTY)
2
Cleared 510(K)
K
95
2422
ELASTIC IMPRESSION CREAM
2
Cleared 510(K)
K
93
5898
HYDROGUM
2
Cleared 510(K)
K
95
3374
PERMADYNE GARANT 2:1
2
Cleared 510(K)
K
95
2693
RAMITEC PENTA
2
Cleared 510(K)
K
95
3027
PERMADYNE PENTA (HIGH & LOW VISCOSITY)
2
Cleared 510(K)
K
95
0299
CEREC 2
2
Cleared 510(K)
K
95
1237
ALGI-BAND
2
Cleared 510(K)
K
95
1075
S & C VINYL POLYSILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
94
5142
POLYSIL (VINYL POLYSILOXAN IMPRESSION MATERIAL)
2
Cleared 510(K)
K
94
3388
GC SURFLEX F
2
Cleared 510(K)
K
93
5896
THIXOFLEX
2
Cleared 510(K)
K
94
3574
CAPTURE IMPRESSION MATERIAL
2
Cleared 510(K)
K
93
5888
ELITE FAST LIGHT BODY
2
Cleared 510(K)
K
93
5885
ELITE FAST PUTTY SOFT
2
Cleared 510(K)
K
93
5886
ELITE LIGHT BODY
2
Cleared 510(K)
K
93
5887
ELITE REGULAR BODY
2
Cleared 510(K)
K
93
5889
OCCLUFAST
2
Cleared 510(K)
K
93
5884
ELITE PUTTY SOFT
2
Cleared 510(K)
K
93
1242
ELITE PUTTY HARD
2
Cleared 510(K)
K
94
3475
ULTRA HYDROPHILIC ALGINAE
2
Cleared 510(K)
K
94
2219
ALGIDENCO AND ALGIPRINT IMPRESSION MATERIALS
2
Cleared 510(K)
K
94
2666
ORTHALGENAT IMPRESSION MATERIAL
2
Cleared 510(K)
K
94
0860
CHROMACLONE COLOR CHANGING ALGINATE IMPRESS MATERIALS
2
Cleared 510(K)
K
94
0685
PRETREATMENT SOLUTION
2
Cleared 510(K)
K
93
5151
HYDROCOLLOID HEATING UNIT
2
Cleared 510(K)
K
94
0402
SUPERGEL/SUPPRESSED DUST
2
Cleared 510(K)
K
94
0379
EXTRUDE
2
Cleared 510(K)
K
94
0120
ALPHA-DENT
2
Cleared 510(K)
K
93
6070
TREND SET 2 PLUS
2
Cleared 510(K)
K
92
5746
REPLICA
2
Cleared 510(K)
K
93
0248
VINYL POLYSILOXANE 2 COMPONENT VULCANIZING SYSTEM
2
Cleared 510(K)
K
93
3206
EXA BITE REGISTRATION MATERIAL
2
Cleared 510(K)
K
92
1571
1ST IMPRESSION
2
Cleared 510(K)
K
93
2459
FAST SET VINYLPOLYSILOXANE BITE REG. MATERIAL
2
Cleared 510(K)
K
92
6033
VINYL POLYSILOXANE IMPRESSION SYSTEM AND RE'CORD
2
Cleared 510(K)
K
92
5370
TRIANGULAR JAW MICROLARYNGEAL FORCEPS
2
Cleared 510(K)
K
92
3202
Q3 (LIGHT AND UNIVERSAL) IMPRESSION MATERIAL
2
Cleared 510(K)
K
91
4178
CORRECTED-V.P.S.
2
Cleared 510(K)
K
91
4437
CORRECT-S.I.M.
2
Cleared 510(K)
K
89
5901
VITA CEREC SET AND VITA CEREC BLOCS
2
Cleared 510(K)
K
91
2001
CONVERTRAY, MODIFICATION
2
Cleared 510(K)
K
91
3583
CONVERSIL FL AND CONVERSIL P
2
Cleared 510(K)
K
91
3537
MEMOSIL C.D.
2
Cleared 510(K)
K
91
2485
COLTENE PRESIDENT JET LIGHT/REG BODY HYDROPHILIC
2
Cleared 510(K)
K
91
0360
CUTTERSIL FUNCTION ACTIVATOR
2
Cleared 510(K)
K
91
0189
PERFOURM PUTTY SOFT
2
Cleared 510(K)
K
91
0166
CUTTERSIL XL
2
Cleared 510(K)
K
91
0165
CUTTERSIL MUCOSA
2
Cleared 510(K)
K
90
5032
MOUSSE, POLYVINYL SILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
90
4927
HENNSON INTERNATIONAL DENTAL CAD/CAM SYSTEM
2
Cleared 510(K)
K
90
4482
STAT.BR TM
2
Cleared 510(K)
K
90
3292
ACCUFLEX/ACCUMIX VINYL POLY IMPRESSION MATERIALS
2
Cleared 510(K)
K
90
1866
DEGUFLEX (R) CS LIGHT
2
Cleared 510(K)
K
90
1867
DEGUFLEX (R) CS PUTTY
2
Cleared 510(K)
K
90
1865
DEGUFLEX MONOPHASE
2
Cleared 510(K)
K
90
1681
FORMASIL(R)A POLYVINYL SILOXANE LINE
2
Cleared 510(K)
K
89
6468
EOS BLUEPHASE-P AND REDPHASE-P IMPRESSION MATERIAL
2
Cleared 510(K)
K
89
6786
ZONAREX FINAL IMPRESSION COMPOUND
2
Cleared 510(K)
K
89
6785
ZONAREX FINAL IMPRESSION COMPOUND, OPERATORY HEAT/
2
Cleared 510(K)
K
89
6539
PERMADYNE GARANT LOW VISCOSITY
2
Cleared 510(K)
K
89
4282
FIRST IMPRESSION TM
2
Cleared 510(K)
K
89
2412
POLYETHER-RETARDER
2
Cleared 510(K)
K
89
2839
PALGARAPID
2
Cleared 510(K)
K
89
4281
FIRST IMPRESSION WITH CHLORHEXIDINE
2
Cleared 510(K)
K
89
0449
PERMAGUM PUTTY SOFT & PERMAGUM GARRANT
2
Cleared 510(K)
K
89
2935
RESOUND IMPRESSION MATERIAL
2
Cleared 510(K)
K
88
4166
DICOR CERAMIC INLAY - NEW TECHNIC
2
Cleared 510(K)
K
88
3842
DENTAL ALGINATE IMPRESSION MATERIAL W/ANTI. ADDI.
2
Cleared 510(K)
K
88
4381
PALGAFLEX AND PALGAFLEX-QUICK
2
Cleared 510(K)
K
88
2800
COLTENE PRESIDENT JET REGULAR BODY
2
Cleared 510(K)
K
88
2690
IMPRINT VINYL POLYSILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
88
1091
OMNISIL, VINYL POLYSILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
87
2745
VINYL POLYSILOXANE IMPRESSION SYSTEM
2
Cleared 510(K)
K
87
1409
VINYL POLYSILOXANE IMPRESSION SYSTEM
2
Cleared 510(K)
K
87
0011
CONTRASYL IMPRESSION MATERIAL
2
Cleared 510(K)
K
87
0047
COLTENE RAPID
2
Cleared 510(K)
K
86
3288
HYDROPHILIC REPROSIL
2
Cleared 510(K)
K
86
2879
NEW LIGHT-CURING IMPRESSION MATERIAL
2
Cleared 510(K)
K
86
0855
SHUR GEL 4
2
Cleared 510(K)
K
85
3089
SUPER ALGIN, ALGINAMINE, EMPRESS DUSTFREE
2
Cleared 510(K)
K
86
0911
AUSTENAL HYCO ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
86
0532
KERR POL-E-LASTIC DENTAL IMPRESSION MATERIAL
2
Cleared 510(K)
K
86
0146
POLYJEL N.F. (NEW FORMULA)
2
Cleared 510(K)
K
85
4106
BAYSILEX
2
Cleared 510(K)
K
85
3529
IMPREGUM-F
2
Cleared 510(K)
K
85
5111
DISPOSABLE PLASTIC DENT IMPRESSION TRAYS 9 STYLES
2
Cleared 510(K)
K
85
5112
DISPOSABLE 3IN CHECK BITE IMPRESSION TRAYS
2
Cleared 510(K)
K
85
4855
PROOF ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
84
4446
BISICO SL(PUTTY) BISICO S2(REGULAR) S3 HEAVY ETC.
2
Cleared 510(K)
K
85
1388
SEPTOSIL SILICONE FOR PRECISION IMPRESSION
2
Cleared 510(K)
K
85
1469
76 ELW BITE CHECKER SILICONE
2
Cleared 510(K)
K
84
2877
ABSOLUTE VINYL POLYSILOXANE IMPRESS
2
Cleared 510(K)
K
85
0036
COLTENE PRECISE
2
Cleared 510(K)
K
84
4329
SURFLEX F
2
Cleared 510(K)
K
84
2324
PERFOURM
2
Cleared 510(K)
K
84
3145
TWO COMPONENT RTV VINYL SILICONE MATER
2
Cleared 510(K)
K
84
1490
POLYSULFIDE CUSTOM TRAY MATERIAL
2
Cleared 510(K)
K
83
0044
ODONTIC CENTRIC(BITE) REGIST. PASTE
2
Cleared 510(K)
K
83
0083
SHUR GEL
2
Cleared 510(K)
K
82
1221
DENTAL IMPRESSION MATERIAL
2
Cleared 510(K)
K
82
0489
ULTRAFINE TRAY ADHESIVE
2
Cleared 510(K)
K
82
0216
ULTRA-WET
2
Cleared 510(K)
K
82
0183
SYBRON/KERR MIRROR 3
2
Cleared 510(K)
K
82
0061
REVERSIBLE HYDROCOLLOID IMPRESSION MAT
2
Cleared 510(K)
K
81
2679
G-C FIT-CHECKER IMPRESSION MATERIAL
2
Cleared 510(K)
K
81
2406
EXAFLEX IMPRESSION MATERIAL
2
Cleared 510(K)
K
81
1867
SR-ALGICAP
2
Cleared 510(K)
K
81
1767
COLTENE PRESIDENT IMPRESSION MATERIALS
2
Cleared 510(K)
K
81
1667
COLTENE PRESSURE SPOT INDICATOR
2
Cleared 510(K)
K
81
1666
COLTENE COLTEX/COLTOFLAX
2
Cleared 510(K)
K
81
1020
REVERSIBLE HYDROCOLLOID IMPRESSION
2
Cleared 510(K)
K
81
0839
SPOTAR
2
Cleared 510(K)
K
81
0825
POLYVINYL SILICONE IMPRESSION MATERIAL
2
Cleared 510(K)
K
81
0523
SR-IVOSEAL
2
Cleared 510(K)
K
80
2990
ALGINATE/SILICONE CROWN & BRIDGE MATER
2
Cleared 510(K)
K
80
2882
HYDROCOLLOID COMPATIBLE CREAM ALGINATE
2
Cleared 510(K)
K
80
2362
ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
80
2189
DENTLOID
2
Cleared 510(K)
K
80
1587
ASH BLUEPRINT ALGINATE IMPRESSION MATER.
2
Cleared 510(K)
K
80
1380
CROWN DELTA SILICONE IMPRESSION MATERIAL
2
Cleared 510(K)
K
80
0393
POLY SULFIDE IMPRESSION PASTE W/CATALYST
2
Cleared 510(K)
K
80
0548
SUPERSIL
2
Cleared 510(K)
K
80
0485
VINYL POLYSILOXANE IMPRESSION MATERIAL
2
Cleared 510(K)
K
80
0031
PERMADYNE POLYETHER RUBBER IMPRESSION
2
Cleared 510(K)
K
79
2363
SILAGUM
2
Cleared 510(K)
K
79
0595
DENTAL ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
79
0592
IMPRESSION MATERIAL, RUBBER
2
Cleared 510(K)
K
78
2139
ZYLOX
2
Cleared 510(K)
K
78
1689
REFLECT IMPRESSION MATERIAL
2
Cleared 510(K)
K
78
1151
REPROSIL
2
Cleared 510(K)
K
78
1083
DENTAL SILICONE IMPRESSION MATERIAL
2
Cleared 510(K)
K
78
0778
RTV SILICONE HAND KNEADABLE PUTTY
2
Cleared 510(K)
K
78
0164
RTV DENTAL SILICONE
2
Cleared 510(K)
K
77
1938
ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
77
1853
PERMAGUM ADHESIVE
2
Cleared 510(K)
K
77
1627
PERMAGUM
2
Cleared 510(K)
K
77
1248
SILICONE IMPRESSION MATEOIAL
2
Cleared 510(K)
K
76
0981
ALGINATE IMPRESSION MATERIAL
2
Cleared 510(K)
K
76
0753
CUTTER JEL-ALGINATE IMPRESSION MAT.
2
Cleared 510(K)
K
76
0755
CUTTER SIL-SILICONE IMPRESSION MAT
2
Cleared 510(K)
K
76
0752
CUTTER FLEX-SILICONE IMPRESSION MAT.
2
Cleared 510(K)
K
76
0238
IMPRESSION MATERIAL, TRIFLEX SILICONE
2
Cleared 510(K)
K
76
0240
IMPRESSION MATERIAL, TRIFLEX SILICONE
2
Cleared 510(K)
K
76
0231
IMPRESSION MATERIAL, DENTAL SILICON RTV
2
Cleared 510(K)
K
76
0225
PUTTY, ACCOE
2
Cleared 510(K)
K
76
0226
PASTE, ACCOE IMPRESSION
2
Cleared 510(K)
ELY
Mercury
2
Product Code
ELZ
Crown, Preformed
1
Product Code
EMA
Cement, Dental
2
Product Code
EMB
Zinc Oxide Eugenol
1
Product Code
JER
Cleaner, Denture, Mechanical
1
Product Code
KCR
Facebow
1
Product Code
KCS
Pantograph
1
Product Code
KIF
Resin, Root Canal Filling
2
Product Code
KLE
Agent, Tooth Bonding, Resin
2
Product Code
KOL
Adhesive, Denture, Carboxymethylcellulose Sodium (32%) And Ethylene-Oxide Homopolymer
1
Product Code
KOM
Adhesive, Denture, Acacia And Karaya With Sodium Borate
1
Product Code
KON
Adhesive, Denture, Polyacrylamide Polymer (Modified Cationic)
3
Product Code
KOO
Adhesive, Denture, Polyvinyl Methylether Maleic Acid Calcium-Sodium Double Salt
1
Product Code
KOP
Adhesive, Denture, Karaya
1
Product Code
KOQ
Adhesive, Denture, Carboxymethylcellulose Sodium (40-100&)
1
Product Code
KOR
Adhesive, Denture, Karaya With Sodium Borate
3
Product Code
KOS
Adhesive, Denture, Carboxymethylcellulose Sodium And Cationic Polyacrylamide Polymer
3
Product Code
KOT
Carboxymethylcellulose Sodium Or Polyvinyl Methylether Maleic Acid Calcium-Sodium
1
Product Code
KXR
Applicator, Resin
1
Product Code
KXW
Adhesive, Denture, Carboxymethylcellulose Sodium (49%) And Ethylene-Oxide Homopolymer
1
Product Code
KXX
Adhesive, Denture, Karaya And Ethylene-Oxide Homopolymer
1
Product Code
KXY
Polyvinyl Methylether Maleic Anhydride &/Or Acid Copolymer & Carboxymethylce
3
Product Code
KZN
Scanner, Color
2
Product Code
KZO
Ink, Arch Tracing
1
Product Code
KZP
Solution, Cement Dissolving
2
Product Code
LBH
Varnish, Cavity
2
Product Code
LPK
Bone Grafting Material, For Dental Bone Repair
2
Product Code
LYC
Bone Grafting Material, Synthetic
2
Product Code
LZD
Joint, Temporomandibular, Implant
3
Product Code
MMT
Resin, Root Canal Filling Containing Chloroform
3
Product Code
MMU
Adhesive, Denture, Acacia And Karaya With Sodium Borate > 12% By Weight
3
Product Code
MPI
Glenoid Fossa Prosthesis
3
Product Code
MPJ
Interarticular Disc Prosthesis (Interpositional Implant)
3
Product Code
MPL
Mandibular Condyle Prosthesis
3
Product Code
MZW
Dental Cement W/Out Zinc-Oxide Eugenol As An Ulcer Covering For Pain Relief
2
Product Code
NDP
Accessories, Implant, Dental, Endosseous
1
Product Code
NFE
Materials, Polytetrafluoroethylene Vitreous Carbon, For Maxillofacial Alveolar Ridge Augmentation
2
Product Code
NHA
Abutment, Implant, Dental, Endosseous
2
Product Code
NKJ
Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
1
Product Code
NME
Bur, Diamond Coated, Reprocessed
1
Product Code
NOF
System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
2
Product Code
NPK
Barrier, Synthetic, Intraoral
2
Product Code
NPL
Barrier, Animal Source, Intraoral
2
Product Code
NPM
Bone Grafting Material, Animal Source
2
Product Code
NPZ
Bone Grafting Material, Dental, With Biologic Component
3
Product Code
NQA
Biologic Material, Dental
3
Product Code
NRQ
Blade-Form Endosseous Dental Implant
2
Product Code
NUN
Bone Grafting Material, Human Source
2
Product Code
NUX
Cleanser, Denture, Prescription
1
Product Code
NYD
Endodontic Kit
2
Product Code
OAT
Implant, Endosseous, Orthodontic
2
Product Code
NYE
Fixture Mount Kit
1
Product Code
OFW
Restorative Instrument And Component Tray
2
Product Code
OFY
Dental Implant Surgical Tray
1
Product Code
OIV
Dental Amalgam
2
Product Code
PHR
Diammine Silver Fluoride Dental Hypersensitivity Varnish
2
Product Code
PME
External Cleaning Solution
2
Product Code
PNP
Dental Abutment Design Software For Dental Laboratory
2
Product Code
POW
Crown And Bridge, Long-Term Temporary, Resin
2
Product Code
PZY
Additively Manufactured, Preformed, Resin Denture Tooth
2
Product Code
QJK
Intraoral Camera
2
Product Code
QRQ
Non-Irrigation Endosseous Dental Implant Drill Bits
1
Product Code
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Subpart G—General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
Subpart G—Miscellaneous Devices
CFR Sub-Part
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
DE
/
subpart-d—prosthetic-devices
/
ELW
/
K012767
View Source
S & C HYDRO VINYL POLYSILOXANE IMPRESSION MATERIAL
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K012767
510(k) Type
Traditional
Applicant
S & C Polymer GmbH
Country
Germany
FDA Decision
Substantially Equivalent
Decision Date
11/1/2001
Days to Decision
76 days
Submission Type
Statement
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Miscellaneous
Subpart B—Diagnostic Devices
Subpart B—Physical Medicine Diagnostic Devices
Subpart D—Physical Medicine Prosthetic Devices
Subpart D—Prosthetic Devices
DZS
Capsule, Dental, Amalgam
DYH
Adhesive, Bracket And Tooth Conditioner, Resin
DZE
Implant, Endosseous, Root-Form
EBC
Sealant, Pit And Fissure, And Conditioner
EBD
Coating, Filling Material, Resin
EBE
Coating, Denture Hydrophilic, Resin
EBF
Material, Tooth Shade, Resin
EBG
Crown And Bridge, Temporary, Resin
EBH
Material, Impression Tray, Resin
EBI
Resin, Denture, Relining, Repairing, Rebasing
EBL
Pin, Retentive And Splinting, And Accessory Instruments
EBO
Denture Repair Kit
EBP
Reliner, Denture, Over The Counter
EFD
Amalgamator, Dental, Ac-Powered
EFT
Cleanser, Denture, Over The Counter
EGG
Attachment, Precision, All
EHE
Dispenser, Mercury And/Or Alloy
EHO
Bar, Preformed
EHP
Clasp, Preformed
EHQ
Cusp, Preformed
EHR
Pad, Denture, Over The Counter
EHS
Cushion, Denture, Over The Counter
EIT
Applicator, Rapid Wax, Dental
EJH
Alloy, Metal, Base
EJJ
Alloy, Amalgam
EJK
Liner, Cavity, Calcium Hydroxide
EJL
Bur, Dental
EJP
Articulators
EJS
Alloy, Other Noble Metal
EJT
Alloy, Gold-Based Noble Metal
EJW
Clasp, Wire
EJX
Anchor, Preformed
EKL
Point, Silver, Endodontic
EKM
Gutta-Percha
EKN
Point, Paper, Endodontic
EKO
Denture Preformed (Partially Prefabricated Denture)
ELE
Implant, Subperiosteal
ELJ
Teeth, Artificial, Posterior With Metal Insert
ELK
Teeth, Artificial, Backing And Facing
ELL
Teeth, Porcelain
ELM
Denture, Plastic, Teeth
ELN
Teeth, Preformed Gold Denture
ELO
Cusp, Gold And Stainless Steel
ELR
Post, Root Canal
ELS
Splint, Endodontic Stabilizing
ELW
Material, Impression
K
25
3501
Hydro Print Premium Fast Set - 454g (1lb) (052037); Hydro Print Premium Regular Set - 454g (1lb) (052327); Chroma Print Premium Fast Set - 454g (1lb) (052457); Chroma Print Premium Regular Set - 454g (1lb) (051460); Perfil Pro - 454g (1lb) (056213); Perfil Pro+ - 454g (1lb) (056121); Perfil Pro Chroma - 454g (1lb) (056122); Hydro Print Premium Fast Set - Multi Pack (056205); Hydro Print Premium Regular Set - Multi Pack (056208); Hydro Print Premium Fast Set - 9,07Kg (20lb) (056204);
K
25
0969
JET BITE; JET BLUE BITE FAST; JET BLUE BITE SUPERFAST
K
24
1924
Elastic Impression Material
K
24
2360
Speedex Light Body; Speedex Medium; Speedex Putty; Speedex Putty Soft; Speedex Universal Activator
K
23
3954
Chemi-SiL (HB, MB, LB, LBS); Chemi-SiL Bite-Blu
K
22
3892
DentMix VPS Impression Material
K
21
3175
No Stress Impress
K
21
4086
Bright Impress-Light, Bright Impress-Medium, Bright Impress-Heavy, Bright Impress-Bite, Bright Impress-Putty
K
22
2741
DENU Light Body(Regular, Fast), DENU Heavy Body(Regular, Fast), DENU Putty Set(Regular, Fast)
K
21
3244
Accusil Dental Impression Materials (Accusil Light Body Regular and Fast Set, Accusil Heavy Body Regular and Fast Set, Accusil Monophase Regular and Fast Set, Accusil Putty Regular and Fast Set, Accusil Bite Registration)
K
22
1668
Dental Impression Material
K
21
3890
IMICRYL Impression Materials
K
22
0257
Permadyne
K
22
0097
PRESIDENT The Original
K
21
1489
Dental Impression Material
K
20
3824
VPS Impression Material
K
21
0041
HySil Plus Impression Materials
K
20
1483
Impression Material
K
20
1684
A-Silicone for Bite Registration
K
20
1184
Lascod Impression Materials
K
19
2941
HySil Super Fast Impression Materials
K
19
0571
StoneBite and StoneBite scan
K
19
1034
VPS Impression Material
K
18
1604
Sildent Fast Light Body, Sildent Fast Heavy Body, Sildent Bite
K
18
1236
HySil Impression Materials
K
18
1011
AIM2
K
18
0565
PEAK NS033CF, PEAK NS017CF
K
17
1562
Dynax clear, Dynax putty, Dynax heavy body, Dynax light, Dynax mono
K
17
3318
Rapid HB, Rapid LB, Rapid MB
K
17
0812
HygePLUS Alginate Impression Material
K
17
0736
HySil Impression Materials
K
15
2615
Vonflex S
K
16
1774
i-Sil
K
16
0097
Image Fast Set, Image Regular Set
K
16
0441
Identic and KromaFaze Alginate Dental Impression Materials
K
15
2826
NoCord
K
15
2766
CharmFlex
K
15
2861
Aquasil Ultra + Smart Wetting Impression Material
K
15
2518
Vonflex S Putty
K
15
2349
Star+ VPS Scannable Impression Material
K
15
1535
Cavex Cream Alginate
K
15
2180
PEAK
K
15
1262
Hyflex Heavy, Hyflex Mono, Hyflex Light
K
15
1150
Elements
K
14
3575
Accu-Dent XD Tray, Accu-Dent XD Syringe
K
14
3382
DentiAnn Smart Sil
K
14
1092
MARK3
K
14
0966
VONFLEX S BITE
K
13
2869
SILDENT
K
14
0602
FLASH PENTA MB QUICK, FLASH MB QUICK
K
13
3071
ELASTIC IMPRESSION MATERIAL
K
14
0074
HYGEDENT ALGINATE IMPRESSION MATERIAL
K
13
4008
MD-FLEX HEAVY BODY
K
13
3527
SUFLEX PUTTY, SUFLEX HEAVY, SUFLEX MONO, SUFLEX LIGHT
K
13
3436
FLASH AR; FLASH AR QUICK
K
13
3400
FLASH BITE
K
13
2599
SMILEBOND SYSTEM
K
13
1510
POLYDIMETHYLSILOXANE IMPRESSION MATERIAL
K
13
0920
CORRECT PLUS 1
K
13
1404
FLASH AR PENTA / FLASH AR PENTA QUICK
K
13
0869
TAKE 1 ADVANCE
K
13
0647
XANTASIL DYNAMIX FAST SET CARTRIDGE -2 X 380ML; XANTASIL FAST SET CARTRIDGE -6 X 50ML
K
12
1824
ALGINOR ALGINELLE TYPE 1 AND 2 MILLENIUM KROMOPAN 1 AND 2
K
12
0914
FLEXITIME FAST & SCAN LIGHT FLOW
K
11
3574
FLEXITIME MONOPHASE PRO SCAN
K
12
0013
TEMPSPAN CLEAR MATRIX
K
12
0521
GC BLUE SILICONE
K
12
0438
FLASH (DIFFERENT MATERIALS)
K
11
3406
AQUASIL ULTRA SMART WETTING IMPRESSION MATERIAL
K
11
3279
IDENTIUM HEAVY, IDENTIUM MEDIUM, IDENTIUM SCAN HEAVY, IDENTIUM SCAN MEDIUM, IDENTIUM SCAN LIGHT
K
11
3263
ARGES IMAGING CONTRAST SPRAY
K
11
0871
FIT CHECKER ADVANCED
K
11
0092
TAKE 1 ADVANCED RIGID TRAY
K
11
0378
IMPRESSION COMPOUND
K
10
3586
IOS FASTSCAN SPRAY
K
11
0050
FIT TEST C&B
K
10
3346
DELIKIT PUTTY, DELIKIT HEAVY BODY, DELIKIT LIGHT BODY
K
10
2836
BONASIL A+ IMPRESSION MATERIALS
K
10
2770
FLEXTIME FAST & SCAN PUTTY, FLEXTIME FAST & SCAN LIGHT FLOW, FLEXTIME FAST & SCAN MEDIUM FLOW
K
10
2739
HYDROCOLOR 5
K
10
3164
VONFLEX HEAVY, VINFLEX LIGHT
K
10
1617
FLEXITIME XTREME 2 HEAVY TRAY CARTRIDGE REFILL, FEXITIME XTREME 2 LIGHT TRAY CARTRIDGE REFILL
K
09
2176
TAKE 1 ADVANCED RIGID TRAY
K
09
1613
TAKE 1
K
09
2867
IDENTIUM HEAVY, MEDIUM, MEDIUM SOFT, LIGHT
K
09
2319
STAR VPS, MODEL 80014-01, FIRST QUATER, MODEL 90649, FIRST HALF, MODEL 89387
K
09
1494
FLEXITIME FLOW
K
09
1267
VONFLEX PUTTY
K
08
3739
HYDRORISE AND HYDROSYSTEM
K
08
3701
PANASIL INITIAL CONTACT AND PANASIL TRAY
K
08
2591
FLEXITIME BITE
K
08
2560
PANASIL IMPRESSION MATERIALS, INCLUDING PUTTY, BINETICS, TRAY, MONOPHASE AND CONTACT
K
08
2157
KETTOSIL AND SILGINAT
K
08
1017
TEMPLATE AND COUNTER-FIT
K
08
1084
COLORISE RIGID
K
08
1120
FUTAR (FUTAR, FUTAR D, FUTAR D FAST, FUTAR D SLOW, FUTAR SCAN BITE REGISTRATION MATERIALS
K
08
0338
CUTTERSIL ACTIVATOR UNIVERSAL PLUS
K
08
0882
CEREC OPTI SPRAY
K
08
0514
PECD-01 AND PECD QUICK-01
K
08
0130
OCCLUFAST CAD
K
07
3475
SYSTEM PLUS
K
07
3005
ELITE GLASS
K
07
2577
BISICO IMPRESSION SILICONES & ALGINATES
K
07
2622
STANDOUT 2
K
07
2245
EMULATE ADVANCED
K
07
1192
BLUGOO HD
K
07
0677
COLORISE
K
07
0700
FREEALGIN
K
06
2400
IMPRESSIX, COLORCHANGE ALGINATE
K
06
0891
VIRTUAL
K
06
1267
SIMULATE, COLOR CHANGE ALGINATE
K
06
1427
PRE-IMPRESSION CONDITIONING SOLUTION
K
05
3619
COLORBITE
K
05
3427
FRESH, DENTAL IMPRESSION MATERIAL
K
05
1933
EXPASYL POWER APPLICATOR
K
05
2455
IMPRESSIX
K
05
3014
POLY SILOXANE IMPRESSION MATERIAL
K
05
3018
POLY SILOXANE IMPRESSION MATERIAL
K
05
2409
SILGIMIX ALGINATE REPLACEMENT IMPRESSION MATERIAL
K
05
2090
SPLASH! IMPRESSION MATERIAL DEVICE
K
05
1797
FUTURE WASH/YPS
K
05
0417
ELITE IMPLANT
K
05
1424
HYDROGUM 5
K
05
1535
MODIFICATION TO:REGISTRADO X-TRA
K
05
1243
JET BLUE BITE
K
05
1207
CAVEX ORTHOTRACE
K
05
0604
KERR VPS IMPRESSION MATERIAL
K
04
3493
FUSION PUTTY TYPE
K
04
3054
GENIE MAGIC MIX ULTRA HYDROPHILIC IMPRESSION MATERIAL
K
05
0013
RETRACTOFOAM
K
04
3471
FUSION FAST
K
04
3118
HYDROGUM SOFT
K
04
2878
FLEXITIME XTREME
K
04
3131
TORPICALGIN
K
04
2860
CORRECT DENTAL IMPRESSION MATERIAL
K
04
1398
GC FUSION
K
04
1229
MULTIPLE (ADDITION SILICONE IMPRESSION MATERIAL)
K
04
1028
CROWN DELTA HYDROPHILIC IMPRESSION MATERIAL
K
04
0053
PRECISION VPS IMPRESSION MATERIAL
K
03
2708
PLASTALGIN AND PLASTALGIN ORTHO
K
03
2289
FIT CHECKER II
K
03
1439
ALGINATE IMPRESSION MATERIAL III (FAST & REGULAR)
K
03
2116
TULIP COLORSWITCH
K
03
2001
POLY Q (GARANT L, PENTA M, PENTA H)
K
03
1484
STAND OUT
K
03
0776
MEGA BITE REGISTRATION - DENTAL BITE REGISTRATION MATERIAL
K
03
0414
GENIE ULTRA HYDROPHILIC IMPRESSION MATERIAL
K
03
0318
P2 POLYETHER
K
02
3751
EXAJET
K
02
4041
ZETAPLUS SOFT
K
02
4034
OCCLUFAST ROCK
K
02
3466
TULIP ALGINATE IMPRESSION MATERIAL
K
02
2653
ELITE MONOPHASE
K
02
2430
ISO FUNCTIONAL
K
02
2066
REGISTRADO X-TRA
K
02
1416
AQUASIL ULTRA MONOPHASE/HEAVY/LV SMART WETTING IMPRESSION MATERIAL
K
02
1413
AQUASIL ULTRA RIGID SMART WETTING IMPRESSION MATERIAL
K
02
1410
AQUASIL ULTRA XLV SMART WETTING IMPRESSION MATERIAL
K
02
0242
EMULATE FAST SET AND EMULATE REGULAR SET
K
01
3859
RHODIA BITE REGISTRATION MATERIAL
K
01
2767
S & C HYDRO VINYL POLYSILOXANE IMPRESSION MATERIAL
K
01
2517
CEREC3 VITABLOCKS
K
01
3336
XANTALGIN CRONO
K
01
3237
STATUSBLUE
K
01
3236
LUXABITE
K
01
3140
RHODIA HYDROPHILIC DENTAL IMPRESSION MATERIAL
K
01
3129
RHODIA DENTAL PUTTY IMPRESSION MATERIAL
K
01
2405
EXTRUDE MODIFIED
K
01
1785
NOVEL PRINT CYAN ALGINATES
K
01
1452
CAVEX STABISIL
K
01
1419
CAVEX COLORCHANGE
K
01
1450
SILICONE IMPRESSION MATERIAL
K
01
0994
TAKE ONE BITE MODIFIED
K
01
0926
R-SI-LINE METAL-BITE
K
00
3808
TAKE 1
K
00
3650
PERMLASTIC 3
K
00
3930
FLEXTIME MAGNUM 360
K
00
3426
ALGINATE IMPRESSION MATERIAL
K
00
1655
PERMLASTIC 2
K
00
1414
KWIKKMODEL
K
00
1876
TAKE 1 BITE
K
00
1218
CORRECT PLUS
K
00
0686
KROM-ALGINATE AND ALGINATE PLUS
K
99
4027
ACTIVATOR PASTE
K
00
0878
HONIGUM
K
00
0629
FLEXTIME
K
00
0595
DIMENSION PENTA L
K
00
0591
DIMENSION PENTA H, DIMENSION PENTA H QUICK
K
00
0588
DIMENSION GARANT L, DIMENSION GARANT L QUICK
K
99
4172
CEREC 3
K
99
4192
IMPREGUM PENTA M MONOSOFT
K
99
4193
IMPREGUM PENTA DUOSOFT
K
99
4190
IMPREGUM GARANT L DUOSOFT
K
99
4077
AROMA FINE (NORMAL AND FAST SET)
K
99
2001
TRAY-LINK
K
99
2895
IMPREGUM F
K
99
2897
IMPREGUM PENTA
K
99
1631
FASTRAY LC
K
99
1489
ALGINATE IMPRESSION MATERIAL I (FAST & REGULAR SET)
K
99
1490
ALGINATE IMPRESSION MATERIAL II (FAST & REGULAR SET)
K
99
1008
DIMENSION BITE
K
99
1425
XANTOPREN COMFORT
K
99
1221
VESTOGUM
K
98
3106
1ST IMPRESSION
K
98
2917
B-SYSTEM SILICONE
K
98
1970
ALGETRAL, CAVEX CHROMATIC, CA 37 SUPERIOR PINK, CA 37 FAST SET, CAVEX RAINBOW, CAVEX IMPRESSIONAL NORMAL SETTING, CAVEXI
K
98
1325
3M M.G. MATERIAL
K
98
0968
LONE STAR IMPRESSION SYSTEMS
K
98
1091
NEOCOLLOID, ORTHOPRINT
K
98
0963
HONIGUM AUTOMIX IMPRESSION MATERIAL (FOIL BAGS) AND HONIGUM QUICK IMPRESSION MATERIAL (CARTRIDGES)
K
98
0965
SPECTRA FORM CHROMATIC ALGINATE IMPRESSION MATERIAL
K
97
4894
KROMATICA COLOR CHANGING ALGINATE
K
97
4704
HYDROGUM
K
97
4231
POSITION PENTA, POSITION PENTA QUICK
K
97
3781
AQUASIL EASY MIX PUTTY IMPRESSION MATERIAL
K
97
3782
AQUASIL XLV SMART WETTING IMPRESSION MATERIAL
K
97
3694
PROVIL NOVO
K
97
3343
HYDROFLEX
K
97
2871
GENESIS
K
97
0129
TULIP
K
97
2276
CEREC 2 CROWN SOFTWARE
K
97
2239
ELITE H-D VINYL POLYSILOXANE IMPRESSION MATERIALS .PUTTY SOFT/NORMAL SETTING /PUTTY SOFT/FAST SETTING
K
97
2027
ELITE H-D HYDROPHILIC VINYL POLYSILOXANE IMPRESSION MATERIALS (LIGHT BODY/NORMAL,LIGHT BODY/FAST SETTING,REGULAR BODY,)
K
97
1155
MEMOREG
K
97
0656
HYDROFLEX
K
96
5083
SUPER-DENT ALGINATE,NORMAL SET, FAST SET,SUPER DELUXE DUSTLESS ALGINATE, NORMAL SET, DELUXE DUTLESS ALGINATE, FAST SET
K
97
0594
KALGINATE IMPRESSION MATERIAL
K
97
0433
AQUASIL RIGID SMART WETTING IMPRESSION MATERIAL
K
96
5165
CUTTERSIL COMFORT HARDENER
K
96
5163
CUTTERSIL COMFORT
K
96
4692
PERFECTIM
K
96
4177
KROMALGIN IMPRESSION MATERIAL
K
96
4323
CHROMOPRINT CHROMATIC ALGINATE IMPRESSION MATERIAL
K
96
3609
PHASE PLUS
K
96
3766
3M PROPLUS SYSTEM
K
96
3205
ALGINMAX, ORTHOCHROME
K
96
2680
HYUNJAE DENTAL IMPRESSION MATERIALS
K
96
2741
TRI-PHASIX CHROMATIC ALGINATE
K
95
2614
JELTRATE PLUS ANTIMICROBIAL IMPR. MATERIAL
K
95
4281
PANASIL IMPRESSION MATERIAL
K
96
1201
BOSWORTH IMPRESSION MATERIAL II
K
96
0547
DIMENSION PENTA/DIMENSION GARANT L/POLYVINYL SILOXANE ADHESIVE
K
95
5932
EXAFLEX IMPRESSION MATERIAL (MODIFICATION)
K
95
5892
HYDROCOLLOID TRAY MATERIALS, MED. TO HIGH VISCOSITY/WASH MATERIALS, LOW VISCOSITY
K
96
0063
BOSWORTH IMPRESSION MATERIAL I
K
95
5465
DEGUPRINT
K
95
5406
SCAN WHITE 12 ML
K
95
4192
IMPREGUM PENTA
K
95
4180
MICROGLISS
K
95
4662
THERMALASTIC/TRIPOLYVINALENE
K
93
5892
INDURENT GEL
K
95
4223
AMERICAN DENTAL PRODUCTS ALGINATE FLAVORING
K
95
2728
RETRAC
K
95
2930
DENTRAY II PLUS TRAY ADHESIVE
K
93
5890
ZETAPLUS (PUTTY)
K
95
2422
ELASTIC IMPRESSION CREAM
K
93
5898
HYDROGUM
K
95
3374
PERMADYNE GARANT 2:1
K
95
2693
RAMITEC PENTA
K
95
3027
PERMADYNE PENTA (HIGH & LOW VISCOSITY)
K
95
0299
CEREC 2
K
95
1237
ALGI-BAND
K
95
1075
S & C VINYL POLYSILOXANE IMPRESSION MATERIAL
K
94
5142
POLYSIL (VINYL POLYSILOXAN IMPRESSION MATERIAL)
K
94
3388
GC SURFLEX F
K
93
5896
THIXOFLEX
K
94
3574
CAPTURE IMPRESSION MATERIAL
K
93
5888
ELITE FAST LIGHT BODY
K
93
5885
ELITE FAST PUTTY SOFT
K
93
5886
ELITE LIGHT BODY
K
93
5887
ELITE REGULAR BODY
K
93
5889
OCCLUFAST
K
93
5884
ELITE PUTTY SOFT
K
93
1242
ELITE PUTTY HARD
K
94
3475
ULTRA HYDROPHILIC ALGINAE
K
94
2219
ALGIDENCO AND ALGIPRINT IMPRESSION MATERIALS
K
94
2666
ORTHALGENAT IMPRESSION MATERIAL
K
94
0860
CHROMACLONE COLOR CHANGING ALGINATE IMPRESS MATERIALS
K
94
0685
PRETREATMENT SOLUTION
K
93
5151
HYDROCOLLOID HEATING UNIT
K
94
0402
SUPERGEL/SUPPRESSED DUST
K
94
0379
EXTRUDE
K
94
0120
ALPHA-DENT
K
93
6070
TREND SET 2 PLUS
K
92
5746
REPLICA
K
93
0248
VINYL POLYSILOXANE 2 COMPONENT VULCANIZING SYSTEM
K
93
3206
EXA BITE REGISTRATION MATERIAL
K
92
1571
1ST IMPRESSION
K
93
2459
FAST SET VINYLPOLYSILOXANE BITE REG. MATERIAL
K
92
6033
VINYL POLYSILOXANE IMPRESSION SYSTEM AND RE'CORD
K
92
5370
TRIANGULAR JAW MICROLARYNGEAL FORCEPS
K
92
3202
Q3 (LIGHT AND UNIVERSAL) IMPRESSION MATERIAL
K
91
4178
CORRECTED-V.P.S.
K
91
4437
CORRECT-S.I.M.
K
89
5901
VITA CEREC SET AND VITA CEREC BLOCS
K
91
2001
CONVERTRAY, MODIFICATION
K
91
3583
CONVERSIL FL AND CONVERSIL P
K
91
3537
MEMOSIL C.D.
K
91
2485
COLTENE PRESIDENT JET LIGHT/REG BODY HYDROPHILIC
K
91
0360
CUTTERSIL FUNCTION ACTIVATOR
K
91
0189
PERFOURM PUTTY SOFT
K
91
0166
CUTTERSIL XL
K
91
0165
CUTTERSIL MUCOSA
K
90
5032
MOUSSE, POLYVINYL SILOXANE IMPRESSION MATERIAL
K
90
4927
HENNSON INTERNATIONAL DENTAL CAD/CAM SYSTEM
K
90
4482
STAT.BR TM
K
90
3292
ACCUFLEX/ACCUMIX VINYL POLY IMPRESSION MATERIALS
K
90
1866
DEGUFLEX (R) CS LIGHT
K
90
1867
DEGUFLEX (R) CS PUTTY
K
90
1865
DEGUFLEX MONOPHASE
K
90
1681
FORMASIL(R)A POLYVINYL SILOXANE LINE
K
89
6468
EOS BLUEPHASE-P AND REDPHASE-P IMPRESSION MATERIAL
K
89
6786
ZONAREX FINAL IMPRESSION COMPOUND
K
89
6785
ZONAREX FINAL IMPRESSION COMPOUND, OPERATORY HEAT/
K
89
6539
PERMADYNE GARANT LOW VISCOSITY
K
89
4282
FIRST IMPRESSION TM
K
89
2412
POLYETHER-RETARDER
K
89
2839
PALGARAPID
K
89
4281
FIRST IMPRESSION WITH CHLORHEXIDINE
K
89
0449
PERMAGUM PUTTY SOFT & PERMAGUM GARRANT
K
89
2935
RESOUND IMPRESSION MATERIAL
K
88
4166
DICOR CERAMIC INLAY - NEW TECHNIC
K
88
3842
DENTAL ALGINATE IMPRESSION MATERIAL W/ANTI. ADDI.
K
88
4381
PALGAFLEX AND PALGAFLEX-QUICK
K
88
2800
COLTENE PRESIDENT JET REGULAR BODY
K
88
2690
IMPRINT VINYL POLYSILOXANE IMPRESSION MATERIAL
K
88
1091
OMNISIL, VINYL POLYSILOXANE IMPRESSION MATERIAL
K
87
2745
VINYL POLYSILOXANE IMPRESSION SYSTEM
K
87
1409
VINYL POLYSILOXANE IMPRESSION SYSTEM
K
87
0011
CONTRASYL IMPRESSION MATERIAL
K
87
0047
COLTENE RAPID
K
86
3288
HYDROPHILIC REPROSIL
K
86
2879
NEW LIGHT-CURING IMPRESSION MATERIAL
K
86
0855
SHUR GEL 4
K
85
3089
SUPER ALGIN, ALGINAMINE, EMPRESS DUSTFREE
K
86
0911
AUSTENAL HYCO ALGINATE IMPRESSION MATERIAL
K
86
0532
KERR POL-E-LASTIC DENTAL IMPRESSION MATERIAL
K
86
0146
POLYJEL N.F. (NEW FORMULA)
K
85
4106
BAYSILEX
K
85
3529
IMPREGUM-F
K
85
5111
DISPOSABLE PLASTIC DENT IMPRESSION TRAYS 9 STYLES
K
85
5112
DISPOSABLE 3IN CHECK BITE IMPRESSION TRAYS
K
85
4855
PROOF ALGINATE IMPRESSION MATERIAL
K
84
4446
BISICO SL(PUTTY) BISICO S2(REGULAR) S3 HEAVY ETC.
K
85
1388
SEPTOSIL SILICONE FOR PRECISION IMPRESSION
K
85
1469
76 ELW BITE CHECKER SILICONE
K
84
2877
ABSOLUTE VINYL POLYSILOXANE IMPRESS
K
85
0036
COLTENE PRECISE
K
84
4329
SURFLEX F
K
84
2324
PERFOURM
K
84
3145
TWO COMPONENT RTV VINYL SILICONE MATER
K
84
1490
POLYSULFIDE CUSTOM TRAY MATERIAL
K
83
0044
ODONTIC CENTRIC(BITE) REGIST. PASTE
K
83
0083
SHUR GEL
K
82
1221
DENTAL IMPRESSION MATERIAL
K
82
0489
ULTRAFINE TRAY ADHESIVE
K
82
0216
ULTRA-WET
K
82
0183
SYBRON/KERR MIRROR 3
K
82
0061
REVERSIBLE HYDROCOLLOID IMPRESSION MAT
K
81
2679
G-C FIT-CHECKER IMPRESSION MATERIAL
K
81
2406
EXAFLEX IMPRESSION MATERIAL
K
81
1867
SR-ALGICAP
K
81
1767
COLTENE PRESIDENT IMPRESSION MATERIALS
K
81
1667
COLTENE PRESSURE SPOT INDICATOR
K
81
1666
COLTENE COLTEX/COLTOFLAX
K
81
1020
REVERSIBLE HYDROCOLLOID IMPRESSION
K
81
0839
SPOTAR
K
81
0825
POLYVINYL SILICONE IMPRESSION MATERIAL
K
81
0523
SR-IVOSEAL
K
80
2990
ALGINATE/SILICONE CROWN & BRIDGE MATER
K
80
2882
HYDROCOLLOID COMPATIBLE CREAM ALGINATE
K
80
2362
ALGINATE IMPRESSION MATERIAL
K
80
2189
DENTLOID
K
80
1587
ASH BLUEPRINT ALGINATE IMPRESSION MATER.
K
80
1380
CROWN DELTA SILICONE IMPRESSION MATERIAL
K
80
0393
POLY SULFIDE IMPRESSION PASTE W/CATALYST
K
80
0548
SUPERSIL
K
80
0485
VINYL POLYSILOXANE IMPRESSION MATERIAL
K
80
0031
PERMADYNE POLYETHER RUBBER IMPRESSION
K
79
2363
SILAGUM
K
79
0595
DENTAL ALGINATE IMPRESSION MATERIAL
K
79
0592
IMPRESSION MATERIAL, RUBBER
K
78
2139
ZYLOX
K
78
1689
REFLECT IMPRESSION MATERIAL
K
78
1151
REPROSIL
K
78
1083
DENTAL SILICONE IMPRESSION MATERIAL
K
78
0778
RTV SILICONE HAND KNEADABLE PUTTY
K
78
0164
RTV DENTAL SILICONE
K
77
1938
ALGINATE IMPRESSION MATERIAL
K
77
1853
PERMAGUM ADHESIVE
K
77
1627
PERMAGUM
K
77
1248
SILICONE IMPRESSION MATEOIAL
K
76
0981
ALGINATE IMPRESSION MATERIAL
K
76
0753
CUTTER JEL-ALGINATE IMPRESSION MAT.
K
76
0755
CUTTER SIL-SILICONE IMPRESSION MAT
K
76
0752
CUTTER FLEX-SILICONE IMPRESSION MAT.
K
76
0238
IMPRESSION MATERIAL, TRIFLEX SILICONE
K
76
0240
IMPRESSION MATERIAL, TRIFLEX SILICONE
K
76
0231
IMPRESSION MATERIAL, DENTAL SILICON RTV
K
76
0225
PUTTY, ACCOE
K
76
0226
PASTE, ACCOE IMPRESSION
ELY
Mercury
ELZ
Crown, Preformed
EMA
Cement, Dental
EMB
Zinc Oxide Eugenol
JER
Cleaner, Denture, Mechanical
KCR
Facebow
KCS
Pantograph
KIF
Resin, Root Canal Filling
KLE
Agent, Tooth Bonding, Resin
KOL
Adhesive, Denture, Carboxymethylcellulose Sodium (32%) And Ethylene-Oxide Homopolymer
KOM
Adhesive, Denture, Acacia And Karaya With Sodium Borate
KON
Adhesive, Denture, Polyacrylamide Polymer (Modified Cationic)
KOO
Adhesive, Denture, Polyvinyl Methylether Maleic Acid Calcium-Sodium Double Salt
KOP
Adhesive, Denture, Karaya
KOQ
Adhesive, Denture, Carboxymethylcellulose Sodium (40-100&)
KOR
Adhesive, Denture, Karaya With Sodium Borate
KOS
Adhesive, Denture, Carboxymethylcellulose Sodium And Cationic Polyacrylamide Polymer
KOT
Carboxymethylcellulose Sodium Or Polyvinyl Methylether Maleic Acid Calcium-Sodium
KXR
Applicator, Resin
KXW
Adhesive, Denture, Carboxymethylcellulose Sodium (49%) And Ethylene-Oxide Homopolymer
KXX
Adhesive, Denture, Karaya And Ethylene-Oxide Homopolymer
KXY
Polyvinyl Methylether Maleic Anhydride &/Or Acid Copolymer & Carboxymethylce
KZN
Scanner, Color
KZO
Ink, Arch Tracing
KZP
Solution, Cement Dissolving
LBH
Varnish, Cavity
LPK
Bone Grafting Material, For Dental Bone Repair
LYC
Bone Grafting Material, Synthetic
LZD
Joint, Temporomandibular, Implant
MMT
Resin, Root Canal Filling Containing Chloroform
MMU
Adhesive, Denture, Acacia And Karaya With Sodium Borate > 12% By Weight
MPI
Glenoid Fossa Prosthesis
MPJ
Interarticular Disc Prosthesis (Interpositional Implant)
MPL
Mandibular Condyle Prosthesis
MZW
Dental Cement W/Out Zinc-Oxide Eugenol As An Ulcer Covering For Pain Relief
NDP
Accessories, Implant, Dental, Endosseous
NFE
Materials, Polytetrafluoroethylene Vitreous Carbon, For Maxillofacial Alveolar Ridge Augmentation
NHA
Abutment, Implant, Dental, Endosseous
NKJ
Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
NME
Bur, Diamond Coated, Reprocessed
NOF
System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
NPK
Barrier, Synthetic, Intraoral
NPL
Barrier, Animal Source, Intraoral
NPM
Bone Grafting Material, Animal Source
NPZ
Bone Grafting Material, Dental, With Biologic Component
NQA
Biologic Material, Dental
NRQ
Blade-Form Endosseous Dental Implant
NUN
Bone Grafting Material, Human Source
NUX
Cleanser, Denture, Prescription
NYD
Endodontic Kit
OAT
Implant, Endosseous, Orthodontic
NYE
Fixture Mount Kit
OFW
Restorative Instrument And Component Tray
OFY
Dental Implant Surgical Tray
OIV
Dental Amalgam
PHR
Diammine Silver Fluoride Dental Hypersensitivity Varnish
PME
External Cleaning Solution
PNP
Dental Abutment Design Software For Dental Laboratory
POW
Crown And Bridge, Long-Term Temporary, Resin
PZY
Additively Manufactured, Preformed, Resin Denture Tooth
QJK
Intraoral Camera
QRQ
Non-Irrigation Endosseous Dental Implant Drill Bits
Subpart E—Surgical Devices
Subpart F—Physical Medicine Therapeutic Devices
Subpart F—Therapeutic Devices
Subpart G—General Hospital and Personal Use Miscellaneous Devices
Subpart G—Miscellaneous Devices
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
DE
/
subpart-d—prosthetic-devices
/
ELW
/
K012767
View Source
S & C HYDRO VINYL POLYSILOXANE IMPRESSION MATERIAL
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K012767
510(k) Type
Traditional
Applicant
S & C Polymer GmbH
Country
Germany
FDA Decision
Substantially Equivalent
Decision Date
11/1/2001
Days to Decision
76 days
Submission Type
Statement