BYS
Oxygenator, Long Term Support Greater Than 6 Hours
2
Product Code
DRY
Monitor, Blood-Gas, On-Line, Cardiopulmonary Bypass
2
Product Code
DTL
Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
2
Product Code
DTM
Filter, Blood, Cardiopulmonary Bypass, Arterial Line
2
Product Code
DTN
Reservoir, Blood, Cardiopulmonary Bypass
2
Product Code
DTP
Defoamer, Cardiopulmonary Bypass
2
Product Code
DTQ
Console, Heart-Lung Machine, Cardiopulmonary Bypass
2
Product Code
DTR
Heat-Exchanger, Cardiopulmonary Bypass
2
Product Code
DTS
Sucker, Cardiotomy Return, Cardiopulmonary Bypass
2
Product Code
DTW
Monitor And/Or Control, Level Sensing, Cardiopulmonary Bypass
2
Product Code
DTX
Gas Control Unit, Cardiopulmonary Bypass
2
Product Code
DTY
Sensor, Blood-Gas, In-Line, Cardiopulmonary Bypass
2
Product Code
DTZ
Oxygenator, Cardiopulmonary Bypass
2
Product Code
DWA
Control, Pump Speed, Cardiopulmonary Bypass
2
Product Code
DWB
Pump, Blood, Cardiopulmonary Bypass, Roller Type
2
Product Code
DWC
Controller, Temperature, Cardiopulmonary Bypass
2
Product Code
DWD
Suction Control, Intracardiac, Cardiopulmonary Bypass
2
Product Code
DWE
Tubing, Pump, Cardiopulmonary Bypass
2
Product Code
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
2
Product Code
DWP
Dilator, Vessel, Surgical
2
Product Code
DWQ
Stripper, Vein, External
2
Product Code
DWS
Instruments, Surgical, Cardiovascular
1
Product Code
DWX
Stripper, Artery, Intraluminal
2
Product Code
DWZ
Device, Biopsy, Endomyocardial
2
Product Code
DXC
Clamp, Vascular
2
Product Code
DXS
Gauge, Pressure, Coronary, Cardiopulmonary Bypass
2
Product Code
JOD
Filter, Blood, Cardiotomy Suction Line, Cardiopulmonary Bypass
2
Product Code
JOR
Generator, Pulsatile Flow, Cardiopulmonary Bypass
3
Product Code
KFM
Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type
2
Product Code
K
25
1762
Quantum Perfusion Centrifugal Blood Pump CP20NG with Integrated Sensors (CP20V-NG)
2
Cleared 510(K)
K
25
0326
Quantum Perfusion Centrifugal Blood Pump CP22NG with Integrated Sensors (CP22V-NG)
2
Cleared 510(K)
K
23
3091
Quantum Perfusion Centrifugal Blood Pump CP37 with Integrated Sensors (CP37V-VT); Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors (CP22V-VT)
2
Cleared 510(K)
K
23
2132
LifeSPARC System
2
Cleared 510(K)
K
22
0842
Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors, Quantum Perfusion Centrifugal Blood Pump CP20 with Integrated Sensors
2
Cleared 510(K)
K
20
0091
Capiox iCP Centrifugal Pump
2
Cleared 510(K)
K
20
1320
Quantum PureFlow Centrifugal Blood Pump CP22 with Integrated Sensor
2
Cleared 510(K)
K
19
3663
FloPump 57mL Centrifugal Pump
2
Cleared 510(K)
K
20
2169
Quantum PureFlow Centrifugal Blood Pump CP37, Quantum PureFlow Centrifugal Blood Pump CP22
2
Cleared 510(K)
K
20
1068
Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortiva BioActive Surface
2
Cleared 510(K)
K
19
2850
Quantum PureFlow Centrifugal Blood Pump CP37, Quantum PureFlow Centrifugal Blood Pump CP22
2
Cleared 510(K)
K
19
1077
Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortive BioActive Surface, Medtronic External Drive Motor
2
Cleared 510(K)
K
19
0650
Revolution Centrifugal Blood Pump
2
Cleared 510(K)
K
18
3623
LifeSPARC Pump, LifeSPARC Controller
2
Cleared 510(K)
K
17
0029
FloPump 32mL, Sterile, FloPump 32mL, Non-Sterile
2
Cleared 510(K)
K
13
2712
AFFINITY CP CENTRIFUGAL BLOOD PUMP WITH OR WITHOUT COATING, AFFINITY CP ADAPTER
2
Cleared 510(K)
K
13
3265
QUADROX-IR ADULT AND SMALL ADULT
2
Cleared 510(K)
K
11
2229
SARN CENTRIFUGAL PUMP
2
Cleared 510(K)
K
11
0493
TANDEMHEART PUMP
2
Cleared 510(K)
K
11
1972
AFFINITY CP CENTRIFUGAL PUMP, RESTING HEART SYS.,MYOTHERM CARDIOPLEGIA DELIV.,AFFINITY HOLLOW FIBER OXYGENATOR,AAF
2
Cleared 510(K)
K
11
1658
AFFINITY CP CENTRIFUGAL BLLOD PUMP WITH CARMEDA BIOACTIVE SURFACE
2
Cleared 510(K)
K
11
1657
AFFINITY CP CENTRIFUGAL BLOOD PUMP WITH BALANCE BIOSURFACE
2
Cleared 510(K)
K
11
1384
LIFEBRIDGE
2
Cleared 510(K)
K
11
0845
IMPELLA CONTROLLER WITH FLOW CONTROL
2
Cleared 510(K)
K
10
3357
LIFEBRIDGE
2
Cleared 510(K)
K
09
3801
IMPELLA CONTROLLER
2
Cleared 510(K)
K
10
0631
AFFIITY CP CENTRIFUGAL BLOOD PUMP
2
Cleared 510(K)
K
09
0515
ROTAFLOW CENTRIFUGAL PUMP WITH SOFTLINE COATING, MODEL BO-RF-32 (USA)
2
Cleared 510(K)
K
09
0051
LEVITRONIX PEDIMAG BLOOD PUMP, MODEL 201-90052
2
Cleared 510(K)
K
08
3794
MECC SET WITH BIOLINE COATING
2
Cleared 510(K)
K
08
3111
IMPELLA 5.0 CATHETER FAMILY
2
Cleared 510(K)
K
08
2321
TERUMO ROCSAFE HYBRID PERFUSION SYSTEM
2
Cleared 510(K)
K
08
0470
ROTA FLOW CENTRIFUGAL PUMP WITH BIOLINE COATING, MODELS BE-RF-32, BEQ-RF-32
2
Cleared 510(K)
K
07
3631
ORQIS EXTRACORPOREAL BLOOD PUMPING SYSTEM, MODEL BPS-100
2
Cleared 510(K)
K
06
3723
IMPELLA RECOVER LP 2.5 PERCUTANEOUS CARDIAC SUPPORT SYSTEM
2
Cleared 510(K)
K
08
0774
CAPIOX SP PUMP (WITH OR WITHOUT X-COATING)
2
Cleared 510(K)
K
06
1072
ROTAFLOW CENTRIFUGAL PUMP WITH SAFELINE COATING, MODEL BSQ-RF-32
2
Cleared 510(K)
K
05
1209
LEVITRONIX CENTRIMAG BACK-UP CONSOLE
2
Cleared 510(K)
K
05
0890
ECC.O SYSTEM
2
Cleared 510(K)
K
05
0109
TRILLIUM BIOPUMP PLUS, MODEL BPX80T
2
Cleared 510(K)
K
03
3270
NOVOSCI READY SYSTEM, MODEL RS-200
2
Cleared 510(K)
K
03
2040
IDEAL MIMESYS SYSTEM WITH INTEGRATED VENOUS AIR REMOVAL, CENTRIFUGAL BLOOD PUMP, PUMP BRACKET, ADULT MEMBRANE OXYGENATOR
2
Cleared 510(K)
K
03
1300
IBC FLOPUMP WITH GBS COATING
2
Cleared 510(K)
K
03
0154
IDEAL: SYSTEM WITH INTEGRATED VENOUS AIR REMOVAL, CENTRIFUGAL BLOOD PUMP, PUMP BRACKET, ADULT MEMBRANE OXYGENATOR
2
Cleared 510(K)
K
02
0271
LEVITRONIX CENTRIMAG EXTRACORPOREAL BLOOD PUMPING SYSTEM, MODEL L-100
2
Cleared 510(K)
K
03
0462
COBE REVOLUTION CENTRIFUGAL BLOOD PUMP WITH PC, MODEL 050300700
2
Cleared 510(K)
K
02
3132
JOSTRA MECC SYSTEM
2
Cleared 510(K)
K
02
0529
LARGE CENTRIFUGAL BLOOD PUMP, MODEL CP-2
2
Cleared 510(K)
K
01
2325
CARDIOVENTION CORX SYSTEM, MODEL FG 0001
2
Cleared 510(K)
K
02
0998
SARNS CENTRIFUGAL PUMP WITH XCOATING, MODEL 164275X
2
Cleared 510(K)
K
01
1835
COBE REVOLUTION
2
Cleared 510(K)
K
01
3393
HEPARIN COATED MINIATURE CENTRIFUGAL BYPASS PUMP SYSTEM;MODEL #CP-1H
2
Cleared 510(K)
K
01
2209
CAPIOX SP PUMP WITH X-COATING PRODUCT CODE: CXSP45X
2
Cleared 510(K)
K
99
1783
AB-180 XC SYSTEM, MODEL AB-180XC
2
Cleared 510(K)
K
99
1864
ROTAFLOW CENTRIFUGAL PUMP SYSTEM
2
Cleared 510(K)
K
99
2592
A-MINIATURE CENTRIFUGAL BLOOD PUMP SYSTEM, MODEL CPB 2000
2
Cleared 510(K)
K
98
3272
IBC FLOPUMP, MODEL 6000
2
Cleared 510(K)
K
97
3011
BPX80 BIO-PUMP (BPX80)
2
Cleared 510(K)
K
97
2740
HIMEX CENTRIFLOW CENTRIFUGAL PERFUSION PUMP SYSTEM (CFK01)
2
Cleared 510(K)
K
96
2981
CAPIOX SP PUMP HEAD
2
Cleared 510(K)
K
95
2879
SARNS CENTRIFUGAL PUMP WITH DURAFLO II TREATMENT
2
Cleared 510(K)
K
94
3861
CAPIOX SP PUMP HEAD
2
Cleared 510(K)
K
93
3014
LIFESTREAM CENTRIFUGEL PUMP INTERFACE #210PI
2
Cleared 510(K)
K
91
5547
SARNS 8000 DELPHIN II CENTRI PUMP MOD W/INTEGR BAT
2
Cleared 510(K)
K
91
5363
SARNS 7850 CENTRIFUGAL PUMP (MODIFIED)
2
Cleared 510(K)
K
92
1550
LIFESTREAM CENTRIFUGAL PUMP SYSTEM MODEL 2100CP
2
Cleared 510(K)
K
91
3176
DELPHIN II CENTRIFUGAL SYSTEM
2
Cleared 510(K)
K
91
2604
SJM/CAD ISOFLOW(TM) CENTRIFUGAL PUMP 2100CP, MODIF
2
Cleared 510(K)
K
90
3925
ARIES MELDICAL MODEL 2100HC HANK CRANK
2
Cleared 510(K)
K
90
2404
SARNS DELPHIN CENTRIFUGAL SYSTEM W/DIRECTION. FLOW
2
Cleared 510(K)
K
90
2198
SARNS DELPHIN BASE ADAPTER WITH BATTERY
2
Cleared 510(K)
K
90
0601
SARNS DELPHIN BASE ADAPTER WITH MINI-BATTERY
2
Cleared 510(K)
K
89
4255
ST.JUDE MEDICAL PULSE 2100 CENTRIFUGAL PUMP
2
Cleared 510(K)
K
88
4659
SARNS 9000 WITH CENTRIFUGAL PUMP OPTION
2
Cleared 510(K)
K
88
2129
SYMBION CENTRIFUGAL BLOOD PUMP MODEL I
2
Cleared 510(K)
K
88
2758
CENTRIFUGAL PUMP SYSTEM LX/DX VERSION
2
Cleared 510(K)
K
85
4975
ELECATH PULSATILE PERFUSION PUMP
2
Cleared 510(K)
K
85
2807
BIO MEDICUS BIO PUMP MODEL BP-50
2
Cleared 510(K)
K
85
2698
BIO MEDICUS BIO PUMP MODEL BP-80
2
Cleared 510(K)
K
85
1855
BIO MEDICUS BIO PUMP MODEL BP-90
2
Cleared 510(K)
K
85
1613
CENTRIMED SYSTEM 1 W/SYSTEM 1 ADAPTER
2
Cleared 510(K)
K
84
2007
CENTRIMED SYSTEM 1
2
Cleared 510(K)
K
78
0953
MODEL 1861 BLOOD PUMP
2
Cleared 510(K)
K
77
0937
PUMP, BYPASS, PULSATILE, AVCO
2
Cleared 510(K)
KRI
Accessory Equipment, Cardiopulmonary Bypass
1
Product Code
KRJ
Filter, Prebypass, Cardiopulmonary Bypass
2
Product Code
KRL
Detector, Bubble, Cardiopulmonary Bypass
2
Product Code
LXN
Probe, Test, Heart-Valve
1
Product Code
MCW
Catheter, Peripheral, Atherectomy
2
Product Code
MFY
Endothelial Cell Harvesting Kit
2
Product Code
MGZ
Valvulotome
2
Product Code
MJJ
Cpb Check Valve, Retrograde Flow, In-Line
2
Product Code
MJN
Catheter, Intravascular Occluding, Temporary
2
Product Code
MNJ
Valve, Pressure Relief, Cardiopulmonary Bypass
2
Product Code
MWS
Stabilizer, Heart
1
Product Code
NCP
Cannula, Arterial, Cardiopulmonary Bypass (Cpb), Embolism Protection
2
Product Code
NLJ
Stripper, Vein, External, Reprocessed
2
Product Code
NMF
Clamp, Vascular, Reprocessed
2
Product Code
NQG
Stabilizer, Heart, Non-Compression, Reprocessed
1
Product Code
OET
Cardioplegia Solution Administration Kit
2
Product Code
OEU
Cardiopulmonary Bypass Catheter Kit
2
Product Code
OFA
Cardiovascular Surgical Instruments Tray
1
Product Code
OFG
Ct Biopsy Tray
2
Product Code
PNQ
Apical Closure Device
2
Product Code
PYX
Temporary Non-Roller Type Right Heart Support Blood Pump
3
Product Code
PTN
Reservoir, Blood, Cardiopulmonary Bypass, Exempt
2
Product Code
PZS
Dual Lumen Ecmo Cannula
2
Product Code
QJZ
Extracorporeal System For Long-Term Respiratory / Cardiopulmonary Failure
2
Product Code
QNR
Blood Pump For Ecmo, Long-Term (> 6 Hours) Use
2
Product Code
QOH
Extracorporeal System For Carbon Dioxide Removal
2
Product Code
QHW
Single Lumen Ecmo Cannula
2
Product Code
QTF
Reprocessed Atherectomy Catheter
2
Product Code
QWF
Tubing, Long Term Support Greater Than 6 Hours
2
Product Code
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Cardiovascular Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 17 April 2026 at 11:17 pm
CV
/
subpart-e—cardiovascular-surgical-devices
/
KFM
/
K013393
View Source
HEPARIN COATED MINIATURE CENTRIFUGAL BYPASS PUMP SYSTEM;MODEL #CP-1H
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K013393
510(k) Type
Special
Applicant
A-Med Systems, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
11/9/2001
Days to Decision
25 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
Subpart B—Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart D—Cardiovascular Prosthetic Devices
Subpart E—Cardiovascular Surgical Devices
BYS
Oxygenator, Long Term Support Greater Than 6 Hours
DRY
Monitor, Blood-Gas, On-Line, Cardiopulmonary Bypass
DTL
Adaptor, Stopcock, Manifold, Fitting, Cardiopulmonary Bypass
DTM
Filter, Blood, Cardiopulmonary Bypass, Arterial Line
DTN
Reservoir, Blood, Cardiopulmonary Bypass
DTP
Defoamer, Cardiopulmonary Bypass
DTQ
Console, Heart-Lung Machine, Cardiopulmonary Bypass
DTR
Heat-Exchanger, Cardiopulmonary Bypass
DTS
Sucker, Cardiotomy Return, Cardiopulmonary Bypass
DTW
Monitor And/Or Control, Level Sensing, Cardiopulmonary Bypass
DTX
Gas Control Unit, Cardiopulmonary Bypass
DTY
Sensor, Blood-Gas, In-Line, Cardiopulmonary Bypass
DTZ
Oxygenator, Cardiopulmonary Bypass
DWA
Control, Pump Speed, Cardiopulmonary Bypass
DWB
Pump, Blood, Cardiopulmonary Bypass, Roller Type
DWC
Controller, Temperature, Cardiopulmonary Bypass
DWD
Suction Control, Intracardiac, Cardiopulmonary Bypass
DWE
Tubing, Pump, Cardiopulmonary Bypass
DWF
Catheter, Cannula And Tubing, Vascular, Cardiopulmonary Bypass
DWP
Dilator, Vessel, Surgical
DWQ
Stripper, Vein, External
DWS
Instruments, Surgical, Cardiovascular
DWX
Stripper, Artery, Intraluminal
DWZ
Device, Biopsy, Endomyocardial
DXC
Clamp, Vascular
DXS
Gauge, Pressure, Coronary, Cardiopulmonary Bypass
JOD
Filter, Blood, Cardiotomy Suction Line, Cardiopulmonary Bypass
JOR
Generator, Pulsatile Flow, Cardiopulmonary Bypass
KFM
Pump, Blood, Cardiopulmonary Bypass, Non-Roller Type
K
25
1762
Quantum Perfusion Centrifugal Blood Pump CP20NG with Integrated Sensors (CP20V-NG)
K
25
0326
Quantum Perfusion Centrifugal Blood Pump CP22NG with Integrated Sensors (CP22V-NG)
K
23
3091
Quantum Perfusion Centrifugal Blood Pump CP37 with Integrated Sensors (CP37V-VT); Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors (CP22V-VT)
K
23
2132
LifeSPARC System
K
22
0842
Quantum Perfusion Centrifugal Blood Pump CP22 with Integrated Sensors, Quantum Perfusion Centrifugal Blood Pump CP20 with Integrated Sensors
K
20
0091
Capiox iCP Centrifugal Pump
K
20
1320
Quantum PureFlow Centrifugal Blood Pump CP22 with Integrated Sensor
K
19
3663
FloPump 57mL Centrifugal Pump
K
20
2169
Quantum PureFlow Centrifugal Blood Pump CP37, Quantum PureFlow Centrifugal Blood Pump CP22
K
20
1068
Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortiva BioActive Surface
K
19
2850
Quantum PureFlow Centrifugal Blood Pump CP37, Quantum PureFlow Centrifugal Blood Pump CP22
K
19
1077
Affinity CP Centrifugal Blood Pump, Affinity CP Centrifugal Blood Pump with Balance Biosurface, Affinity CP Centrifugal Blood Pump with Cortive BioActive Surface, Medtronic External Drive Motor
K
19
0650
Revolution Centrifugal Blood Pump
K
18
3623
LifeSPARC Pump, LifeSPARC Controller
K
17
0029
FloPump 32mL, Sterile, FloPump 32mL, Non-Sterile
K
13
2712
AFFINITY CP CENTRIFUGAL BLOOD PUMP WITH OR WITHOUT COATING, AFFINITY CP ADAPTER
K
13
3265
QUADROX-IR ADULT AND SMALL ADULT
K
11
2229
SARN CENTRIFUGAL PUMP
K
11
0493
TANDEMHEART PUMP
K
11
1972
AFFINITY CP CENTRIFUGAL PUMP, RESTING HEART SYS.,MYOTHERM CARDIOPLEGIA DELIV.,AFFINITY HOLLOW FIBER OXYGENATOR,AAF
K
11
1658
AFFINITY CP CENTRIFUGAL BLLOD PUMP WITH CARMEDA BIOACTIVE SURFACE
K
11
1657
AFFINITY CP CENTRIFUGAL BLOOD PUMP WITH BALANCE BIOSURFACE
K
11
1384
LIFEBRIDGE
K
11
0845
IMPELLA CONTROLLER WITH FLOW CONTROL
K
10
3357
LIFEBRIDGE
K
09
3801
IMPELLA CONTROLLER
K
10
0631
AFFIITY CP CENTRIFUGAL BLOOD PUMP
K
09
0515
ROTAFLOW CENTRIFUGAL PUMP WITH SOFTLINE COATING, MODEL BO-RF-32 (USA)
K
09
0051
LEVITRONIX PEDIMAG BLOOD PUMP, MODEL 201-90052
K
08
3794
MECC SET WITH BIOLINE COATING
K
08
3111
IMPELLA 5.0 CATHETER FAMILY
K
08
2321
TERUMO ROCSAFE HYBRID PERFUSION SYSTEM
K
08
0470
ROTA FLOW CENTRIFUGAL PUMP WITH BIOLINE COATING, MODELS BE-RF-32, BEQ-RF-32
K
07
3631
ORQIS EXTRACORPOREAL BLOOD PUMPING SYSTEM, MODEL BPS-100
K
06
3723
IMPELLA RECOVER LP 2.5 PERCUTANEOUS CARDIAC SUPPORT SYSTEM
K
08
0774
CAPIOX SP PUMP (WITH OR WITHOUT X-COATING)
K
06
1072
ROTAFLOW CENTRIFUGAL PUMP WITH SAFELINE COATING, MODEL BSQ-RF-32
K
05
1209
LEVITRONIX CENTRIMAG BACK-UP CONSOLE
K
05
0890
ECC.O SYSTEM
K
05
0109
TRILLIUM BIOPUMP PLUS, MODEL BPX80T
K
03
3270
NOVOSCI READY SYSTEM, MODEL RS-200
K
03
2040
IDEAL MIMESYS SYSTEM WITH INTEGRATED VENOUS AIR REMOVAL, CENTRIFUGAL BLOOD PUMP, PUMP BRACKET, ADULT MEMBRANE OXYGENATOR
K
03
1300
IBC FLOPUMP WITH GBS COATING
K
03
0154
IDEAL: SYSTEM WITH INTEGRATED VENOUS AIR REMOVAL, CENTRIFUGAL BLOOD PUMP, PUMP BRACKET, ADULT MEMBRANE OXYGENATOR
K
02
0271
LEVITRONIX CENTRIMAG EXTRACORPOREAL BLOOD PUMPING SYSTEM, MODEL L-100
K
03
0462
COBE REVOLUTION CENTRIFUGAL BLOOD PUMP WITH PC, MODEL 050300700
K
02
3132
JOSTRA MECC SYSTEM
K
02
0529
LARGE CENTRIFUGAL BLOOD PUMP, MODEL CP-2
K
01
2325
CARDIOVENTION CORX SYSTEM, MODEL FG 0001
K
02
0998
SARNS CENTRIFUGAL PUMP WITH XCOATING, MODEL 164275X
K
01
1835
COBE REVOLUTION
K
01
3393
HEPARIN COATED MINIATURE CENTRIFUGAL BYPASS PUMP SYSTEM;MODEL #CP-1H
K
01
2209
CAPIOX SP PUMP WITH X-COATING PRODUCT CODE: CXSP45X
K
99
1783
AB-180 XC SYSTEM, MODEL AB-180XC
K
99
1864
ROTAFLOW CENTRIFUGAL PUMP SYSTEM
K
99
2592
A-MINIATURE CENTRIFUGAL BLOOD PUMP SYSTEM, MODEL CPB 2000
K
98
3272
IBC FLOPUMP, MODEL 6000
K
97
3011
BPX80 BIO-PUMP (BPX80)
K
97
2740
HIMEX CENTRIFLOW CENTRIFUGAL PERFUSION PUMP SYSTEM (CFK01)
K
96
2981
CAPIOX SP PUMP HEAD
K
95
2879
SARNS CENTRIFUGAL PUMP WITH DURAFLO II TREATMENT
K
94
3861
CAPIOX SP PUMP HEAD
K
93
3014
LIFESTREAM CENTRIFUGEL PUMP INTERFACE #210PI
K
91
5547
SARNS 8000 DELPHIN II CENTRI PUMP MOD W/INTEGR BAT
K
91
5363
SARNS 7850 CENTRIFUGAL PUMP (MODIFIED)
K
92
1550
LIFESTREAM CENTRIFUGAL PUMP SYSTEM MODEL 2100CP
K
91
3176
DELPHIN II CENTRIFUGAL SYSTEM
K
91
2604
SJM/CAD ISOFLOW(TM) CENTRIFUGAL PUMP 2100CP, MODIF
K
90
3925
ARIES MELDICAL MODEL 2100HC HANK CRANK
K
90
2404
SARNS DELPHIN CENTRIFUGAL SYSTEM W/DIRECTION. FLOW
K
90
2198
SARNS DELPHIN BASE ADAPTER WITH BATTERY
K
90
0601
SARNS DELPHIN BASE ADAPTER WITH MINI-BATTERY
K
89
4255
ST.JUDE MEDICAL PULSE 2100 CENTRIFUGAL PUMP
K
88
4659
SARNS 9000 WITH CENTRIFUGAL PUMP OPTION
K
88
2129
SYMBION CENTRIFUGAL BLOOD PUMP MODEL I
K
88
2758
CENTRIFUGAL PUMP SYSTEM LX/DX VERSION
K
85
4975
ELECATH PULSATILE PERFUSION PUMP
K
85
2807
BIO MEDICUS BIO PUMP MODEL BP-50
K
85
2698
BIO MEDICUS BIO PUMP MODEL BP-80
K
85
1855
BIO MEDICUS BIO PUMP MODEL BP-90
K
85
1613
CENTRIMED SYSTEM 1 W/SYSTEM 1 ADAPTER
K
84
2007
CENTRIMED SYSTEM 1
K
78
0953
MODEL 1861 BLOOD PUMP
K
77
0937
PUMP, BYPASS, PULSATILE, AVCO
KRI
Accessory Equipment, Cardiopulmonary Bypass
KRJ
Filter, Prebypass, Cardiopulmonary Bypass
KRL
Detector, Bubble, Cardiopulmonary Bypass
LXN
Probe, Test, Heart-Valve
MCW
Catheter, Peripheral, Atherectomy
MFY
Endothelial Cell Harvesting Kit
MGZ
Valvulotome
MJJ
Cpb Check Valve, Retrograde Flow, In-Line
MJN
Catheter, Intravascular Occluding, Temporary
MNJ
Valve, Pressure Relief, Cardiopulmonary Bypass
MWS
Stabilizer, Heart
NCP
Cannula, Arterial, Cardiopulmonary Bypass (Cpb), Embolism Protection
NLJ
Stripper, Vein, External, Reprocessed
NMF
Clamp, Vascular, Reprocessed
NQG
Stabilizer, Heart, Non-Compression, Reprocessed
OET
Cardioplegia Solution Administration Kit
OEU
Cardiopulmonary Bypass Catheter Kit
OFA
Cardiovascular Surgical Instruments Tray
OFG
Ct Biopsy Tray
PNQ
Apical Closure Device
PYX
Temporary Non-Roller Type Right Heart Support Blood Pump
PTN
Reservoir, Blood, Cardiopulmonary Bypass, Exempt
PZS
Dual Lumen Ecmo Cannula
QJZ
Extracorporeal System For Long-Term Respiratory / Cardiopulmonary Failure
QNR
Blood Pump For Ecmo, Long-Term (> 6 Hours) Use
QOH
Extracorporeal System For Carbon Dioxide Removal
QHW
Single Lumen Ecmo Cannula
QTF
Reprocessed Atherectomy Catheter
QWF
Tubing, Long Term Support Greater Than 6 Hours
Subpart E—Surgical Devices
Subpart F—Cardiovascular Therapeutic Devices
Subpart F—Therapeutic Devices
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
CV
/
subpart-e—cardiovascular-surgical-devices
/
KFM
/
K013393
View Source
HEPARIN COATED MINIATURE CENTRIFUGAL BYPASS PUMP SYSTEM;MODEL #CP-1H
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K013393
510(k) Type
Special
Applicant
A-Med Systems, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
11/9/2001
Days to Decision
25 days
Submission Type
Summary