LARGE CENTRIFUGAL BLOOD PUMP, MODEL CP-2

K020529 · A-Med Systems, Inc. · KFM · Aug 26, 2002 · Cardiovascular

Device Facts

Record IDK020529
Device NameLARGE CENTRIFUGAL BLOOD PUMP, MODEL CP-2
ApplicantA-Med Systems, Inc.
Product CodeKFM · Cardiovascular
Decision DateAug 26, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.4360
Device ClassClass 2
AttributesTherapeutic

Intended Use

The A-Med Large Centrifugal Blood Pump is indicated for pumping blood through the extracorporeal bypass circuit for extracorporeal circulatory support for periods appropriate to cardiopulmonary bypass (up to six hours). It is also indicated for use in extracorporeal circulatory support systems (for periods up to six hours) not requiring complete cardiopulmonary bypass (e.g., valvuloplasty, circulatory support during mitral valve operations, surgery of the vena cava or aorta, liver transplants, etc). The A-Med Large Centrifugal Blood Pump is indicated for use only with the A-Med Blood Pump Controller.

Device Story

A-Med Large Centrifugal Blood Pump is a sterile, disposable, non-pulsatile, non-roller pump. It uses an impeller to impart energy to blood via centrifugal forces. The pump is demand-responsive, automatically adjusting flow and pressure based on resistance and fluid return. It features a hermetically sealed drive cable and magnetic coupling. The device is used in clinical settings for extracorporeal circulatory support. It requires a separately available motor, ultrasonic flow sensor, and microcomputer-based control console. The healthcare provider operates the system to maintain blood circulation during surgical procedures. The device benefits patients by providing temporary circulatory support during cardiac or vascular surgeries.

Clinical Evidence

No clinical data provided. Substantial equivalence is based on design, material, and performance similarities to predicate devices.

Technological Characteristics

Sterile, disposable, non-pulsatile, non-roller centrifugal pump. Utilizes impeller for energy transfer. Features hermetically sealed drive cable and magnetic coupling. Designed for use with external motor, ultrasonic flow sensor, and microcomputer-based control console. Identical materials and design to predicates, with increased size and pressure capacity.

Indications for Use

Indicated for patients requiring extracorporeal circulatory support during cardiopulmonary bypass or procedures not requiring complete bypass (e.g., valvuloplasty, mitral valve surgery, vena cava/aorta surgery, liver transplants) for up to six hours. Must be used with A-Med Blood Pump Controller.

Regulatory Classification

Identification

A nonroller-type cardiopulmonary and circulatory bypass blood pump is a prescription device that uses a method other than revolving rollers to pump the blood through an extracorporeal circuit for periods lasting less than 6 hours for the purpose of providing either:(i) Full or partial cardiopulmonary bypass (i.e., circuit includes an oxygenator) during open surgical procedures on the heart or great vessels; or(ii) Temporary circulatory bypass for diversion of flow around a planned disruption of the circulatory pathway necessary for open surgical procedures on the aorta or vena cava.

Special Controls

*Classification* —Class II (special controls). The special controls for this device are:(i) Non-clinical performance testing must perform as intended over the intended duration of use and demonstrate the following: Operating parameters, dynamic blood damage, heat generation, air entrapment, mechanical integrity, and durability/reliability; (ii) The patient-contacting components of the device must be demonstrated to be biocompatible; (iii) Sterility and shelf life testing must demonstrate the sterility of patient-contacting components and the shelf life of these components; and (iv) Labeling must include information regarding the duration of use, and a detailed summary of the device- and procedure-related complications pertinent to use of the device. (b) *Nonroller-type temporary ventricular support blood pump* —(1)*Identification.* A nonroller-type temporary ventricular support blood pump is a prescription device that uses any method resulting in blood propulsion to provide the temporary ventricular assistance required for support of the systemic and/or pulmonary circulations during periods when there is ongoing or anticipated hemodynamic instability due to immediately reversible alterations in ventricular myocardial function resulting from mechanical or physiologic causes. Duration of use would be less than 6 hours.(2) *Classification.* Class III (premarket approval).(c) *Date premarket approval application (PMA) or notice of completion of product development protocol (PDP) is required.* A PMA or notice of completion of a PDP is required to be filed with FDA on or before September 8, 2015, for any nonroller-type temporary ventricular support blood pump that was in commercial distribution before May 28, 1976, or that has, on or before September 8, 2015, been found to be substantially equivalent to any nonroller-type temporary ventricular support blood pump that was in commercial distribution before May 28, 1976. Any other nonroller-type temporary ventricular support blood pump shall have an approved PMA or declared completed PDP in effect before being placed in commercial distribution.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K020529 p.113. " ## 510(k) SUMMARY OF SAFETY & EFFECTIVENESS AUG 2 6 2002 This 510(k) Summary details sufficient information to provide an understanding of the basis for a determination of substantial equivalence. For convenience, the summary is formatted pursuant to 21 CFR \$807.92. This section may be used, as presented, to provide a substantial equivalence summary to anyone requesting it from the Agency. #### 21 CFR §807.92 a (1) A-Med Systems, Inc 2491 Boatman Avenue West Sacramento, CA 95691-3817 (916) 375-7400 ext. 5316 Contact person: Cynthia G. Royster Date prepared: 13 February 2002 #### 21 CFR §807.92 a (2) | Trade name: | A-Med Large Centrifugal Blood Pump | |-------------|------------------------------------| |-------------|------------------------------------| | Common name: | Centrifugal Pump | |----------------------|-----------------------------------------------------------------| | Classification name: | "Non-roller type Cardiopulmonary Bypass Blood<br>Pumps"870.4360 | #### 21 CFR §807.92 a (3) Identification of predicate(s): Substantial equivalence for the A-Med Large Centrifugal Blood Pump is based on its similarities to the predicate devices, A-Med Miniature Centrifugal Blood Pump System (K992592) and Medtronic Bio-Medicus Centrifugal Blood Pump (K973011). The line extension A-Med Large Centrifugal Blood Pump is substantially equivalent to the predicates in intended use, material, design, performance and physical characteristics. The line extension included a larger motor to the existing larger housing to enable it to produce more pressure. #### 21 CFR §807.92 a (4) Device Description-parts and function/concept: The A-Med Large Centrifugal Blood Pump is a sterile, disposable, non-pulsatile, non-roller pump that utilizes an impeller to impart energy to the blood through centrifugal forces. The flow of the pump is "demand responsive" by {1}------------------------------------------------ K020529 p.2-13 automatically responding to the resistance against which it is pumping and to the amount of fluid returned to the large pump with the appropriate changes in flow and pressure. A drive cable and magnetic coupling are hermetically sealed components of the pump. A motor ultrasonic flow sensor and a microcomputer-based control console are available separately. #### 21 CFR 8807.92 a (5) Intended use and relationship to predicate(s): The A-Med Large Centrifugal Blood Pump is indicated for pumping blood through the extracorporeal bypass circuit for extracorporeal circulatory support for periods appropriate to cardiopulmonary bypass (up to six hours). It is also indicated for use in extracorporeal circulatory support systems (for periods up to six hours) not requiring complete cardiopulmonary bypass (e.g., valvuloplasty, circulatory support during mitral valve operations, surgery of the vena cava or aorta, liver transplants, etc). The A-Med Large Centrifugal Blood Pump is indicated for use only with the A-Med Blood Pump Controller. #### CFR 8807.92 a (6) Technological characteristics and relationship to predicate(s): The A-Med Large Centrifugal Blood Pump is identical in design, material, intended use and technological characteristics to the predicate devices. The difference is size and pressure only. #### 21 CFR §807.92 b This substantial equivalence is based on similarities to the predicate devices in terms of intended uses and technological characteristics. #### 21 CFR §807.92 c In accordance with the specifications of this subsection, this summary (two pages) is its own section, and has been clearly identified as such. {2}------------------------------------------------ # K020529 p 3 /3 ### Literature (cited) - 1. Driessen JJ. Dhaese H. Fransen G. Verrelst P. Rondelez L. Gevaert L. van Becelaere M, Schelstraete E. "Pulsatile Compared with Nonpulsatile Perfusion Using a Centrifugal pump for Cardiopulmonary Bypass during Coronary Artery Bypass Grafting. Effect on Systemic Haemodynamics. Oxygenation, and Inflammatory Response Parameters", Perfusion 10 No. 1: 3-12 1995. - 2. Glauber M, Szefner J, Senni M, Gamba A, Mamprin F, Fiocchi R, Somachini M, Ferrazzi P. "Reduction of Haemorrhagic Complications during Mechanically Assisted Circulation with the Use of a Multi-System Anticoagulation Protocol", Artificial Organs Vol. 18 No. 10: 649-55 Oct. 1995. - 3. Noon GP, Lafuente JA, Irwin S. " Acute and Temporary Ventricular Support with Bio-Medicus Centrifugal Pump", Ann Thorac Surg. Vol 68 2: 650-4.68 Aug 1999. - 4. Ricardo Grossi Dantas, Eduardo Tavares Costa. "Ultrasonic Pulsed Doppler Blood Flowmeter for Use in Extracorporeal Circulation," Artificial Organs Vol. 24 No.3: 198-201 March 2000. - 5. Takami Y, Makinoushi K, Nakazawa T, Benkowski R, Glueck J, Ohara Y, Nose Y . "Hemolytic characteristics of a Pivot Bearing Supported Gyro Centrifugal Pump (C1E3) Simulating Various Clinical Applications", Artif Organs Vol. 20 No.9: 1042-9 Sept. 1996. {3}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES · USA" around the perimeter. Inside the circle is an abstract symbol that resembles three stylized human profiles facing to the right, stacked on top of each other. **AUG 26 2002** Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 A-Med Systems, Inc. Ms. Cynthia G. Royster Director, Regulatory Affairs 2491 Boatman Avenue West Sacramento, CA 95691-3817 Re: K020529 Trade/Device Name: A-Med Large Centrifugal Blood Pump Regulation Number: 21 CFR 870.4360 Regulation Name: Nonroller-type cardiopulmonary bypass blood pump. Regulatory Class: Class III Product Code: KFM Dated: June 3, 2002 Received: June 21, 2002 Dear Ms. Royster: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set {4}------------------------------------------------ Page 2 - Ms. Cynthia G. Royster forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4586. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely vours. Elia Mallis Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ## Indication Statement Page 510(k) Number (if known): N/A K 020529 Device Name: A-Med Large Centrifugal Blood Pump #### Indications for Use The A-Med Large Centrifugal Blood Pump is indicated for pumping blood through the extracorporeal bypass circuit for extracorporeal circulatory support for periods appropriate to cardiopulmonary bypass (up to six hours). It is also indicated for use in extracorporeal circulatory support systems (for periods up to six hours) not requiring complete cardiopulmonary bypass (e.g., valvuloplasty, circulatory support during mitral valve operations, surgery of the vena cava or aorta, liver transplants, etc). The A-Med Large Centrifugal Blood Pump is indicated for use only with the A-Med Blood Pump Controller. (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use Use (Per 21 CFR 801.109) OR Over-The-Counter Optional Format 1- Elias Mollis Sign-Off Fratory Device imber. >10(; . CONFIDENTIAL 7of 101
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...