PSY · Whole Slide Imaging System

Pathology · 21 CFR 864.3700 · Class 2

Overview

Product CodePSY
Device NameWhole Slide Imaging System
Regulation21 CFR 864.3700
Device ClassClass 2
Review PanelPathology

Identification

The whole slide imaging system is an automated digital slide creation, viewing, and management system intended as an aid to the pathologist to review and interpret digital images of surgical pathology slides. The system generates digital images that would otherwise be appropriate for manual visualization by conventional light microscopy.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

A whole slide imaging system must comply with the following special controls: (1) Premarket notification submissions must include the following information: (i) The indications for use must specify the tissue specimen that is intended to be used with the whole slide imaging system and the components of the system. (ii) A detailed description of the device and bench testing results at the component level, including for the following, as appropriate: (A) Slide feeder; (B) Light source; (C) Imaging optics: (D)Mechanical scanner movement; (E) Digital imaging sensor; (F) Image processing software; (G)Image composition techniques; (H)Image file formats; (I) Image review manipulation software; (J) Computer environment; (K)Display system. (iii)Detailed bench testing and results at the system level, including for the following, as appropriate: (A)Color reproducibility; (B) Spatial resolution; (C) Focusing test; (D) Whole slide tissue coverage; (E) Stitching error: (F) Turnaround time. (iv) Detailed information demonstrating the performance characteristics of the device, including, as appropriate: (A)Precision to evaluate intra-system and inter-system precision using a comprehensive set of clinical specimens with defined, clinically relevant histologic features from various organ systems and diseases. Multiple whole slide imaging systems, multiple sites, and multiple readers must be included. (B) Reproducibility data to evaluate inter-site variability using a comprehensive set of clinical specimens with defined, clinically relevant histologic features from various organ systems and diseases. Multiple whole slide imaging systems, multiple sites, and multiple readers must be included. (C) Data from a clinical study to demonstrate that viewing, reviewing, and diagnosing digital images of surgical pathology slides prepared from tissue slides using the whole slide imaging system is non-inferior to using an optical microscope. The study should evaluate the difference in major discordance rates between manual digital (MD) and manual optical (MO) modalities when compared to the reference (e.g., main sign-out diagnosis). (D) A detailed human factors engineering process must be used to evaluate the whole slide imaging system user interface(s). (2) Labeling compliant with 21 CFR 809.10(b) must include the following: The intended use statement must include the information described in paragraph (i) (1)(i) of this section, as applicable, and a statement that reads, "It is the responsibility of a qualified pathologist to employ appropriate procedures and safeguards to assure the validity of the interpretation of images obtained using this device." (ii) A description of the technical studies and the summary of results, including those that relate to paragraph (1)(ii) and (1)(iii) of this section, as appropriate. (iii) A description of the performance studies and the summary of results, including those that relate to paragraph (1)(iv) of this section, as appropriate. (iv) A limiting statement that specifies that pathologists should exercise professional judgment in each clinical situation and examine the glass slides by conventional microscopy if there is doubt about the ability to accurately render an interpretation using this device alone.

*Classification.* Class II (special controls). The special controls for this device are:(1) Premarket notification submissions must include the following information: (i) The indications for use must specify the tissue specimen that is intended to be used with the whole slide imaging system and the components of the system. (ii) A detailed description of the device and bench testing results at the component level, including for the following, as appropriate: (A) Slide feeder; (B) Light source; (C) Imaging optics; (D) Mechanical scanner movement; (E) Digital imaging sensor; (F) Image processing software; (G) Image composition techniques; (H) Image file formats; (I) Image review manipulation software; (J) Computer environment; and (K) Display system. (iii) Detailed bench testing and results at the system level, including for the following, as appropriate: (A) Color reproducibility; (B) Spatial resolution; (C) Focusing test; (D) Whole slide tissue coverage; (E) Stitching error; and (F) Turnaround time. (iv) Detailed information demonstrating the performance characteristics of the device, including, as appropriate: (A) Precision to evaluate intra-system and inter-system precision using a comprehensive set of clinical specimens with defined, clinically relevant histologic features from various organ systems and diseases. Multiple whole slide imaging systems, multiple sites, and multiple readers must be included. (B) Reproducibility data to evaluate inter-site variability using a comprehensive set of clinical specimens with defined, clinically relevant histologic features from various organ systems and diseases. Multiple whole slide imaging systems, multiple sites, and multiple readers must be included. (C) Data from a clinical study to demonstrate that viewing, reviewing, and diagnosing digital images of surgical pathology slides prepared from tissue slides using the whole slide imaging system is non-inferior to using an optical microscope. The study should evaluate the difference in major discordance rates between manual digital (MD) and manual optical (MO) modalities when compared to the reference ( *e.g.,* main sign-out diagnosis).(D) A detailed human factor engineering process must be used to evaluate the whole slide imaging system user interface(s). (2) Labeling compliant with 21 CFR 809.10(b) must include the following: (i) The intended use statement must include the information described in paragraph (b)(1)(i) of this section, as applicable, and a statement that reads, “It is the responsibility of a qualified pathologist to employ appropriate procedures and safeguards to assure the validity of the interpretation of images obtained using this device.” (ii) A description of the technical studies and the summary of results, including those that relate to paragraphs (b)(1)(ii) and (iii) of this section, as appropriate. (iii) A description of the performance studies and the summary of results, including those that relate to paragraph (b)(1)(iv) of this section, as appropriate. (iv) A limiting statement that specifies that pathologists should exercise professional judgment in each clinical situation and examine the glass slides by conventional microscopy if there is doubt about the ability to accurately render an interpretation using this device alone.

Recent Cleared Devices (20 of 23)

Showing 20 most recent of 23 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253554Aperio GT 450 DX; Aperio GT 180 DXLeica Biosystems Imaging, Inc.Aug 7, 2026SESE
K260964NanoZoomer S540MD Slide Scanner SystemHamamatsu Photonics K.K.Jul 22, 2026SESE
K251952VirasightVirasoft CorporationJul 17, 2026SESE
K253606NanoZoomer S20MD Slide scanner system; NanoZoomer S360MD Slide scanner systemHamamatsu Photonics K.K.Jul 15, 2026SESE
K243871Philips IntelliSite Pathology Solution 5.1Philips Medical Systems Nederland B.V.Mar 6, 2025SESE
K241717E1000 Dx Digital Pathology SolutionShandon Diagnostics LimitedFeb 28, 2025SESE
K242783Roche Digital Pathology DxVentana Medical Systems, Inc.Dec 17, 2024SESE
K242848Philips IntelliSite Pathology Solution 5.1Philips Medical Systems Nederland B.V.Dec 10, 2024SESE
K241871Philips IntelliSite Pathology SolutionPhilips Medical Systems Nederland B.V.Dec 2, 2024SESE
K233204Philips IntelliSite Pathology Solution 5.1Philips Medical Systems Nederland B.V.Jun 24, 2024SESE
K232879Roche Digital Pathology Dx (VENTANA DP 200)Ventana Medical Systems, Inc.Jun 14, 2024SESE
K232833HALO AP DxIndica Labs, Inc.May 7, 2024SESE
K232208Sectra Digital Pathology Module (Version 3.3)Sectra ABApr 16, 2024SESE
K232202Aperio GT 450 DXLeica Biosystems Imaging, Inc.Apr 16, 2024SESE
K230839Concentriq DxProscia, Inc.Feb 8, 2024SESE
K233027NanoZoomer S360MD Slide scanner systemHamamatsu Photonics K.K.Dec 22, 2023SESE
K213883NanoZoomer S360MD Slide scanner systemHamamatsu Photonics K.K.Sep 27, 2022SESE
K203845Philips IntelliSite Pathology SolutionPhilips Medical Systems Nederland B.V.Sep 17, 2021SESE
K203364MDPC-8127Barco N.V.Apr 15, 2021SESE
K192259Philips IntelliSite Pathology SolutionPhilips Electronics Nederland B.V.Sep 20, 2019SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...