LPH · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented

Orthopedic · 21 CFR 888.3358 · Class 2

Overview

Product CodeLPH
Device NameProsthesis, Hip, Semi-Constrained, Metal/Polymer, Porous Uncemented
Regulation21 CFR 888.3358
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.

Classification Rationale

Class II.

Recent Cleared Devices (20 of 565)

Showing 20 most recent of 565 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K261453G7® Acetabular SystemZimmer BiometSep 23, 2026SESE
K253630Mpact 3D Metal FoamMedacta International S.A.Aug 28, 2026SESE
K254043TRIVANCE™ Hip StemGlobus Medical, Inc.Aug 4, 2026SESE
K261624Omnifit® 20° Series I Insert;Omnifit® Crossfire® 10° Series II Insert; Constrained Acetabular Insert; Trident® Crossfire® 0° Polyethylene Insert; Trident ® Crossfire ® 10° Polyethylene Insert;System 12 Crossfire® 10° Insert; Trident® 0° Constrained Acetabular Insert; Trident® Constrained Acetabular Liner;Trident® All Poly Constrained Acetabular Insert; Crossfire® Eccentric Insert 10°; Artisan® Bone Plug;UHR® Universal Head Bipolar ComponentHowmedica Osteonics Corp., Dba Stryker OrthopaedicsJul 10, 2026SESE
K243192iNSitu Lateralized Acetabular Liners, iNSitu Femoral Stems with Plasma Sprayed CPTi CoatingNextstep Arthopedix, LLCJun 5, 2026SESE
K251270Taperloc® Complete Hip StemBiomet, Inc.May 19, 2026SESE
K252623G7® Revision Acetabular SystemZimmer, Inc.Feb 4, 2026SESE
K251043Mpact 3D Metal Implants Extension – DMLS TechnologyMedacta International S.A.Jan 28, 2026SESE
K252067Velora Acetabular SystemRestor3D, Inc.Dec 5, 2025SESE
K252846TaperSet™ Hip SystemShalby Advanced Technologies, Inc. Dba Consensus OrthopedicsNov 20, 2025SESE
K251833EMPOWR Acetabular® Liner ExtensionEncore Medical L.P.Nov 12, 2025SESE
K251718ArTT Augments and Buttresses and Bone ScrewsLima Corporate S.P.A.Aug 29, 2025SESE
K250989Stryker and Serf hip devicesHowmedica Osteonics Corp (Dba Stryker Orthopaedics)Jul 25, 2025SESE
K243456ONVOY™ Acetabular SystemGlobus Medical, Inc.Jun 6, 2025SESE
K242744Trinity EVO Acetabular ShellCorin U.S.A. LimitedJun 5, 2025SESE
K242232Mpact 3D Metal Augments IIMedacta International S.A.Apr 23, 2025SESE
K242045Initia T3 Acetabular Hemispherical Shell SystemKyocera Medical Technologies, Inc.Apr 10, 2025SESE
K243784Stryker Orthopaedics Hip Devices Labeling UpdateHowmedica Osteonics Corp., Dba Stryker OrthopaedicsFeb 6, 2025SESE
K243977EMPHASYS Acetabular SystemDepuy Ireland UCJan 22, 2025SESE
K241059Pantheon Proximal Femur Reconstruction (PFR) SystemAdler Ortho S.P.AJan 13, 2025SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...