LOX · Catheters, Transluminal Coronary Angioplasty, Percutaneous
Cardiovascular · 21 CFR 870.5100 · Class 2
Overview
| Product Code | LOX |
|---|---|
| Device Name | Catheters, Transluminal Coronary Angioplasty, Percutaneous |
| Regulation | 21 CFR 870.5100 |
| Device Class | Class 2 |
| Review Panel | Cardiovascular |
Identification
Standard PTCA Catheter: A PTCA catheter is a device that operates on the principle of hydraulic pressurization applied through an inflatable balloon attached to the distal end. A PTCA balloon catheter has a single or double lumen shaft. The catheter features a balloon of appropriate compliance for the clinical application, constructed from a polymer. The balloon is designed to uniformly expand to a specified diameter and length at a specific pressure as labeled, with well characterized rates of inflation and deflation and a defined burst pressure. The device generally features a type of radiographic marker to facilitate fluoroscopic visualization of the balloon during use. A PTCA catheter is intended for balloon dilatation of a hemodynamically significant coronary artery or bypass graft stenosis in patients evidencing coronary ischemia for the purpose of improving myocardial perfusion. A PTCA catheter may also be intended for the treatment of acute myocardial infarction; treatment of in-stent restenosis (ISR) and/or post-deployment stent expansion. Cutting/scoring PTCA Catheter: A cutting/scoring PTCA catheter is a balloon-tipped catheter with cutting/scoring elements attached, which is used in those circumstances where a high pressure balloon resistant lesion is encountered. A cutting/scoring PTCA catheter is intended for the treatment of hemodynamically significant coronary artery stenosis for the purpose of improving myocardial perfusion. A cutting/scoring PTCA catheter may also be indicated for use in complex type C lesions or for the treatment of in-stent restenosis.
Classification Rationale
Standard PTCA Catheter: Class II (special controls). The special control for this device is “Class II Special Controls Guidance Document for Certain Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheters.” See § 870.1(e) for the availability of this guidance document. Cutting/scoring PTCA Catheter: Class III (premarket approval). As of May 28, 1976, an approval under section 515 of the act is required before this device may be commercially distributed. See § 870.3.
Special Controls
*Classification.* Class II (special controls). The special control for this device is “Class II Special Controls Guidance Document for Certain Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheters.” See § 870.1(e) for the availability of this guidance document.(b) *Cutting/scoring PTCA Catheter* —(1)*Identification.* A cutting/scoring PTCA catheter is a balloon-tipped catheter with cutting/scoring elements attached, which is used in those circumstances where a high pressure balloon resistant lesion is encountered. A cutting/scoring PTCA catheter is intended for the treatment of hemodynamically significant coronary artery stenosis for the purpose of improving myocardial perfusion. A cutting/scoring PTCA catheter may also be indicated for use in complex type C lesions or for the treatment of in-stent restenosis.(2) *Classification.* Class III (premarket approval). As of May 28, 1976, an approval under section 515 of the act is required before this device may be commercially distributed. See § 870.3.
Recent Cleared Devices (20 of 108)
Showing 20 most recent of 108 cleared devices.
| Record | Device Name | Applicant | Decision Date | Decision |
|---|---|---|---|---|
| K252116 | Firefighter™ Pro PTCA Balloon Catheter | Shanghai MicroPort Medical (Group) Co., Ltd. | Apr 7, 2026 | SESE |
| K254022 | FLASH Flex™ Aorto-Ostial Angioplasty System | Verge Medical, Inc. | Apr 2, 2026 | SESE |
| K252295 | Ryurei | Terumo Corporation | Mar 27, 2026 | SESE |
| K251970 | Sprinter Legend Rapid Exchange Balloon Dilatation Catheter | Medtronic, Ireland | Jan 17, 2026 | SESE |
| K242969 | Pantera Pro; Pantera LEO | Biotronik, Inc. | Oct 25, 2024 | SESE |
| K233499 | Sapphire NC ULTRA Coronary Dilatation Catheter | OrbusNeich Medical (Shenzhen) Co., Ltd. | Aug 16, 2024 | SESE |
| K233505 | Sapphire ULTRA Coronary Dilatation Catheter | OrbusNeich Medical (Shenzhen) Co., Ltd. | Aug 15, 2024 | SESE |
| K233729 | Ringer perfusion balloon catheter, 2.00 x 20mm (5881); Ringer perfusion balloon catheter, 2.50 x 20mm (5882); Ringer perfusion balloon catheter, 2.50 x 30mm (5883); Ringer perfusion balloon catheter, 3.00 x 20mm (5884); Ringer perfusion balloon catheter, 3.00 x 30mm (5885); Ringer perfusion balloon catheter, 3.50 x 20mm (5886); Ringer perfusion balloon catheter, 3.50 x 30mm (5887); Ringer perfusion balloon catheter, 4.00 x 20mm (5888); Ringer perfusion balloon catheter, 4.00 x 30mm (58 | Vascular Solutions, LLC | May 31, 2024 | SESE |
| K223189 | Firefighter™ NC Pro PTCA Balloon Catheter | Shanghai MicroPort Medical (Group) Co., Ltd. | Jul 21, 2023 | SESE |
| K230374 | Coronary Dilatation Balloon Catheter (VesPenetrator®), Coronary Dilatation Balloon Catheter (VesTraveler®), Coronary Dilatation Balloon Catheter (VexPander®) | Dongguan TT Medical, Inc. | Jun 29, 2023 | SESE |
| K230705 | POT PTCA Balloon Dilatation Catheter | Brosmed Medical Co., Ltd. | Apr 11, 2023 | SESE |
| K223022 | SC HONKYTONK PTCA Balloon Dilatation Catheter | Sino Medical Sciences Technology, Inc. | Feb 15, 2023 | SESE |
| K222538 | NC ROCKSTAR Non-Compliant PTCA Balloon Dilatation Catheter | Sino Medical Sciences Technology, Inc. | Dec 21, 2022 | SESE |
| K220634 | NC TREK NEO Coronary Dilatation Catheter | Abbott Vascular | Jun 30, 2022 | SESE |
| K220629 | Emerge Monorail PTCA Dilatation Catheter | Boston Scientific | Mar 24, 2022 | SESE |
| K212393 | OPN NC PTCA Dilatation Catheter | Sis Medical AG | Mar 14, 2022 | SESE |
| K211349 | Selebrek PTCA Balloon Dilatation Catheter | Kossel Medtech (Suzhou) Co., Ltd. | Jan 7, 2022 | SESE |
| K211807 | Sapphire NC 24 | OrbusNeich Medical (Shenzhen) Co., Ltd. | Oct 14, 2021 | SESE |
| K210012 | Tamarin Blue PTCA RX Dilatation Catheter | Natec Medical , Ltd. | Jul 9, 2021 | SESE |
| K211393 | Selethru(TM) NC PTCA Balloon Dilatation Catheter | Kossel Medtech (Suzhou) Co., Ltd. | Jul 2, 2021 | SESE |
Top Applicants
- Abbott Vascular — 6 clearances
- Boston Scientific Corp — 6 clearances
- Boston Scientific Corporation — 6 clearances
- Ostial Corporation — 5 clearances
- Advanced Cardiovascular Systems, Inc. — 4 clearances