JGS · Electrode, Ion Specific, Sodium

Clinical Chemistry · 21 CFR 862.1665 · Class 2

Overview

Product CodeJGS
Device NameElectrode, Ion Specific, Sodium
Regulation21 CFR 862.1665
Device ClassClass 2
Review PanelClinical Chemistry
3rd-Party ReviewableYes

Identification

A sodium test system is a device intended to measure sodium in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of aldosteronism (excessive secretion of the hormone aldosterone), diabetes insipidus (chronic excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison's disease (caused by destruction of the adrenal glands), dehydration, inappropriate antidiuretic hormone secretion, or other diseases involving electrolyte imbalance.

Classification Rationale

Class II.

Recent Cleared Devices (20 of 162)

Showing 20 most recent of 162 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K252475ABL90 FLEX PLUS SystemRadiometer Medicals ApsMay 1, 2026SESE
K230275i-STAT CG8+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.Oct 27, 2023SESE
K222438A-LYTE® Integrated Multisensor (IMT Na K Cl)Siemens Healthcare Diagnostics, Inc.Jul 25, 2023SESE
K220977ISE Reagents, Glucose, CRP Latex, DxC 500 AU Clinical Chemistry AnalyzerBeckman Coulter Laboratory Systems (Suzhou) Co., Ltd.Jul 20, 2023SESE
K213486GLP systems TrackAbbott LaboratoriesMar 10, 2022SESE
K200403Stat Profile Prime Plus Analyzer SystemNova Biomedical CorporationApr 14, 2020SESE
K183688i-STAT CHEM8+ cartridge with the i-STAT 1 SystemAbbott Point of Care, Inc.Feb 7, 2020SESE
K191365Stat Profile Prime ES Comp Plus Analyzer SystemNova Biomedical CorporationJul 19, 2019SESE
K172232LIASYS 600 Electrolyte Measurement System, LIASYS 600 Creatinine reagent, LIASYS 600Ams DiagnosticsJun 12, 2019SESE
K183549GEM Premier ChemSTATInstrumentation Laboratory COFeb 16, 2019SESE
K180428Stat Profile Prime Plus Analyzer SystemNova Biomedical CorporationAug 15, 2018SESE
K181201Synermed ISE ReagentsInfrared Laboratory Systems, LLC (Dba Synermed)Jul 10, 2018SESE
K171476SelectaLyte Electrolyte Analyzer (Na+, K+, Cl-)Awareness Technology, Inc.Feb 27, 2018SESE
K161954Atellica Solution, Atellica A-LYTE Integrated Multisensor Na+/K+/CI-, Atellica CH Albumin BCP Reagent (Alb_p), Atellica IM Thyroid Stimulating Hormone TSH, Atellica CH Vancomycin (Vanc)Siemens Healthcare DiagnosticsMar 9, 2017SESE
K161837ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry AnalyzerBeckman Coulter, Inc.Dec 16, 2016SESE
K160225GEM Premier 5000 (Measured Parameters:Sodium, Potassium, Chloride, Ionized Calcium), GEM CVP 5 tBili, GEM System Evaluator, GEM Hematocrit EvaluatorInstrumentation Laboratory CODec 14, 2016SESE
K153357i-STAT Alinity System with i-STAT Sodium testAbbott Point of Care, Inc.Jul 8, 2016SESE
K160370BS-800M/ ABS800/BA-800M ISE KIT, BS-800M Chemistry Analyzer, BA-800M Chemistry Analyzer, ABS800 Chemistry AnalyzerShenzhen Mindray Bio-Medical Electronics Co., Ltd.Jun 9, 2016SESE
K151767Trinidad CH system, TD-LYTE Integrated Multisensor (Na, K, CI), TD-LYTE IMT Standard A, TD-LYTE IMT Standard B + Salt Bridge, Trinidad CH Albumin BCP reagent (Alb_P), Trinidad CH Albumin BCP CalibratorSiemens Healthcare Diagnostics, Inc.Dec 11, 2015SESE
K140373ISE INDIRECT NA, K, C1 FOR GEN 2Roche DiagnosticsMay 22, 2014SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.