PZL · Extracorporeal Shock Wave Device For Treatment Of Diabetic Foot Ulcers

General, Plastic Surgery · 21 CFR 878.4685 · Class 2

Overview

Product CodePZL
Device NameExtracorporeal Shock Wave Device For Treatment Of Diabetic Foot Ulcers
Regulation21 CFR 878.4685
Device ClassClass 2
Review PanelGeneral, Plastic Surgery

Identification

An extracorporeal shock wave device for treatment of chronic wounds is a prescription device that focuses acoustic shock waves onto the dermal tissue. The shock waves are generated inside the device and transferred to the body using an acoustic interface.

Classification Rationale

Class II (special controls). The special controls for this device are:

Special Controls

*Classification.* Class II (special controls). The special controls for this device are:(1) Non-clinical performance testing must be conducted to demonstrate that the system produces anticipated and reproducible acoustic pressure shock waves. (2) The patient-contacting components of the device must be demonstrated to be biocompatible. (3) Performance data must demonstrate that the reusable components of the device can be reprocessed for subsequent use. (4) Performance data must be provided to demonstrate the electromagnetic compatibility and electrical safety of the device. (5) Software verification, validation, and hazard analysis must be performed. (6) Performance data must support the use life of the system by demonstrating continued system functionality over the labeled use life. (7) Physician labeling must include: (i) Information on how the device operates and the typical course of treatment; (ii) A detailed summary of the device's technical parameters; (iii) Validated methods and instructions for reprocessing of any reusable components; and (iv) Instructions for preventing hearing loss by use of hearing protection. (8) Patient labeling must include: (i) Relevant contraindications, warnings, precautions, adverse effects, and complications; (ii) Information on how the device operates and the typical course of treatment; (iii) The probable risks and benefits associated with the use of the device; (iv) Post-procedure care instructions; and (v) Alternative treatments.

Recent Cleared Devices (8 of 8)

RecordDevice NameApplicantDecision DateDecision
K243279DOLORCLAST Focused Shock WavesE.M.S Electro Medical Systems S.AAug 13, 2025SESE
K250779CS-Pro MEDCurative Sound TherapeuticsJul 2, 2025SESE
K233937OW100SSoftwave/Trt, LLCJul 9, 2024SESE
K231710OW100SSoftwave/Trt, LLCSep 1, 2023SESE
K202112Storz Medical Duolith SD1 T-Top & Tower System with C-Actor Sepia HandpieceStorz Medical AGFeb 21, 2021SESE
K200926OrthoGold 100Tissue Regeneration Technologies, LLCAug 28, 2020SESE
K191961OrthoGoldTissue Regeneration TechnologiesNov 26, 2019SESE
DEN160037dermaPACE SystemSanuwave, Inc.Dec 28, 2017DENG

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...