FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
EAG
Cephalometer
2
Product Code
EAH
Cone, Radiographic, Lead-Lined
1
Product Code
EAP
Unit, X-Ray, Intraoral
2
Product Code
EHB
Collimator, X-Ray
1
Product Code
EHD
Unit, X-Ray, Extraoral With Timer
2
Product Code
MUH
System, X-Ray, Extraoral Source, Digital
2
Product Code
EAM
Screen, Intensifying, Radiographic
1
Product Code
EGT
Controller, Temperature, Radiographic
2
Product Code
EGW
Dryer, Film, Radiographic
2
Product Code
EGY
Processor, Radiographic-Film, Automatic, Dental
2
Product Code
HBK
Chair, Pneumoencephalographic
2
Product Code
ITX
Transducer, Ultrasonic, Diagnostic
2
Product Code
ITY
Assembly, Tube Housing, X-Ray, Diagnostic
1
Product Code
IWN
Cassette, Measurement, Ardran-Crooks
1
Product Code
IWY
Holder, Head, Radiographic
1
Product Code
IWZ
Film, Radiographic
1
Product Code
IXA
Cassette, Radiographic Film
2
Product Code
IXC
Illuminator, Radiographic-Film
1
Product Code
IXD
Source, Calibration, Sealed, Nuclear
1
Product Code
IXF
Test-Pattern, Radiographic
1
Product Code
IXG
Phantom, Anthropomorphic, Radiographic
1
Product Code
IXH
Camera, Focal Spot, Radiographic
1
Product Code
IXJ
Grid, Radiographic
1
Product Code
IXK
System, Imaging, X-Ray, Electrostatic
2
Product Code
IXL
Device, Spot-Film
2
Product Code
IXO
Synchronizer, Ecg / Respirator, Radiographic
1
Product Code
IXQ
Table, Radiographic, Stationary Top
2
Product Code
IXR
Table, Radiographic, Tilting
2
Product Code
IXW
Processor, Radiographic-Film, Automatic
2
Product Code
IXX
Processor, Cine Film
2
Product Code
IXY
Holder, Radiographic Cassette, Wall-Mounted
1
Product Code
IYB
Tube Mount, X-Ray, Diagnostic
1
Product Code
IYN
System, Imaging, Pulsed Doppler, Ultrasonic
2
Product Code
IYO
System, Imaging, Pulsed Echo, Ultrasonic
2
Product Code
IYP
Phantom, Anthropomorphic, Nuclear
1
Product Code
IYQ
Phantom, Flood Source, Nuclear
1
Product Code
IYT
System, Rebreathing, Radionuclide
2
Product Code
IYW
Scanner, Rectilinear, Nuclear
1
Product Code
IYX
Camera, Scintillation (Gamma)
1
Product Code
IYY
Synchronizer, Electrocardiograph, Nuclear
1
Product Code
IYZ
Bed, Scanning, Nuclear
1
Product Code
IZC
Camera, Positron
1
Product Code
IZD
Probe, Uptake, Nuclear
1
Product Code
IZF
System, X-Ray, Tomographic
2
Product Code
IZG
System, X-Ray, Photofluorographic
2
Product Code
IZH
System, X-Ray, Mammographic
2
Product Code
IZI
System, X-Ray, Angiographic
2
Product Code
IZJ
Camera, X-Ray, Fluorographic, Cine Or Spot
2
Product Code
IZL
System, X-Ray, Mobile
2
Product Code
IZO
Generator, High-Voltage, X-Ray, Diagnostic
1
Product Code
IZP
Programmer, Changer, Film/Cassette, Radiographic
2
Product Code
IZS
Aperture, Radiographic
2
Product Code
IZT
Cone, Radiographic
2
Product Code
IZW
Collimator, Automatic, Radiographic
2
Product Code
IZX
Collimator, Manual, Radiographic
2
Product Code
IZZ
Table, Radiographic, Non-Tilting, Powered
2
Product Code
JAA
System, X-Ray, Fluoroscopic, Image-Intensified
2
Product Code
JAB
System, X-Ray, Fluoroscopic, Non-Image-Intensified
2
Product Code
JAC
System, X-Ray, Film Marking, Radiographic
1
Product Code
JAF
Monitor, Ultrasonic, Nonfetal
2
Product Code
JAG
Illuminator, Radiographic-Film, Explosion-Proof
1
Product Code
JAK
System, X-Ray, Tomography, Computed
2
Product Code
JAM
Scanner, Whole Body, Nuclear
1
Product Code
JAN
Counter, Whole Body, Nuclear
1
Product Code
JAO
Scanner, Fluorescent
2
Product Code
JAR
Phantom, Test-Pattern, Radionuclide
1
Product Code
JWM
System, Tomographic, Nuclear
2
Product Code
KGI
Densitometer, Bone
2
Product Code
KPR
System, X-Ray, Stationary
2
Product Code
KPS
System, Tomography, Computed, Emission
2
Product Code
KPT
Calibrator, Dose, Radionuclide
2
Product Code
KPW
Device, Beam Limiting, X-Ray, Diagnostic
2
Product Code
KPX
Changer, Radiographic Film/Cassette
2
Product Code
KXH
Cradle, Patient, Radiologic
1
Product Code
KXJ
Table, Radiologic
2
Product Code
LEK
Transilluminator (Diaphanoscope)
3
Product Code
LHO
Instrument, Quality-Assurance, Radiologic
1
Product Code
LLZ
System, Image Processing, Radiological
2
Product Code
K
25
3784
3DICOM MD Cloud
2
Cleared 510(K)
K
25
3639
View
2
Cleared 510(K)
K
25
3008
maiLink
2
Cleared 510(K)
K
25
1883
MIM – LesionID Pro
2
Cleared 510(K)
K
25
1880
Archy Dental Imaging
2
Cleared 510(K)
K
25
3495
syngo.MR Applications (VB80)
2
Cleared 510(K)
K
25
1410
VXvue
2
Cleared 510(K)
K
25
1532
Acorn 3D Software (AC-SEG-4009); Acorn 3DP Model (AC-101-XX)
2
Cleared 510(K)
K
25
2547
TheraSphere 360™ Y-90 Management Platform
2
Cleared 510(K)
K
25
1030
Sirona Advanced Imaging Suite
2
Cleared 510(K)
K
25
2476
Viewer (5.4); Elements Viewer; Mixed Reality Viewer; Smart Layout; Elements Viewer Smart Layout
2
Cleared 510(K)
K
25
2199
AGFA HealthCare Enterprise Imaging
2
Cleared 510(K)
K
25
1363
ProKnow DS
2
Cleared 510(K)
K
25
0039
HPACS
2
Cleared 510(K)
K
25
1215
Philips IntelliSpace Cardiovascular
2
Cleared 510(K)
K
25
0045
uWS-Angio Pro
2
Cleared 510(K)
K
25
0040
uWS-Angio
2
Cleared 510(K)
K
24
2314
Minimally Invasive Prostate Surgery Navigation System(Model:AmaKris SR1-A-2)
2
Cleared 510(K)
K
25
2608
AI-Rad Companion Prostate MR
2
Cleared 510(K)
K
25
1168
Image Suite
2
Cleared 510(K)
K
25
0290
SurgiTwin
2
Cleared 510(K)
K
25
2526
Rapid DeltaFuse
2
Cleared 510(K)
K
24
3680
Neurovascular Insight V1.0
2
Cleared 510(K)
K
23
2456
RW-1
2
Cleared 510(K)
K
25
0664
Navigo Workstation 2.3 (FPRMC00039)
2
Cleared 510(K)
K
25
1038
Digital Radiographic Imaging Acquisition Software - DR (RiasDR)
2
Cleared 510(K)
K
24
4016
iPETcertum (v1.0)
2
Cleared 510(K)
K
25
0716
IMAGE ONE
2
Cleared 510(K)
K
24
3681
Neuro Insight V1.0
2
Cleared 510(K)
K
25
0686
GyriCalc (Version 1.0.0)
2
Cleared 510(K)
K
25
0181
AV Viewer
2
Cleared 510(K)
K
25
0120
GECHO
2
Cleared 510(K)
K
25
1863
CustomSurg OrthoPlanner
2
Cleared 510(K)
K
24
3666
uOmniscan
2
Cleared 510(K)
K
24
4012
Mosaic (V1.0.1)
2
Cleared 510(K)
K
25
0800
UroNav 4
2
Cleared 510(K)
K
24
3703
TechLive
2
Cleared 510(K)
K
25
1109
SMARTDent
2
Cleared 510(K)
K
24
3632
uWS-Angio Basic
2
Cleared 510(K)
K
24
3069
LUMYS (V1)
2
Cleared 510(K)
K
24
3697
MySpine WebPlanner
2
Cleared 510(K)
K
24
3651
VersaViewer
2
Cleared 510(K)
K
24
2647
MySegmenter (v2.0.0)
2
Cleared 510(K)
K
25
0301
Merge Universal Viewer (MUV)
2
Cleared 510(K)
K
24
2552
Horos Mobile
2
Cleared 510(K)
K
24
3292
brAIn™ Shoulder Positioning
2
Cleared 510(K)
K
24
2161
Radlink GPS Pro Imaging
2
Cleared 510(K)
K
24
1975
SERV MEDICAL CDSS
2
Cleared 510(K)
K
24
1765
PLANET Onco Dose (3.2)
2
Cleared 510(K)
K
24
1546
aiCockpit AI Viewer
2
Cleared 510(K)
K
25
0348
JLK-AILink
2
Cleared 510(K)
K
24
2838
QuickRad
2
Cleared 510(K)
K
24
2240
CaRi-Plaque
2
Cleared 510(K)
K
24
1425
AspenView
2
Cleared 510(K)
K
24
3333
rTOP
2
Cleared 510(K)
K
24
1694
ZeTTA PACS
2
Cleared 510(K)
K
24
1819
CephNinja
2
Cleared 510(K)
K
24
2205
SpectoMed (v1.0)
2
Cleared 510(K)
K
24
1808
ApolloHipX (THR.SS.0001)
2
Cleared 510(K)
K
24
2123
Brainomix 360 e-CTA
2
Cleared 510(K)
K
24
1350
Clarify DL
2
Cleared 510(K)
K
24
2599
aprevo® Digital Planning
2
Cleared 510(K)
K
24
2362
Lightning Viewer
2
Cleared 510(K)
K
24
1989
Cercare Medical Neurosuite (CMN) Capillary Function with Virtual Expert
2
Cleared 510(K)
K
24
0926
PeekMed web
2
Cleared 510(K)
K
24
3447
Rapid Surgical Plan (RSP-SW-001)
2
Cleared 510(K)
K
24
2810
RadUnity (Version 1.0.0)
2
Cleared 510(K)
K
24
1495
Jazz Classic
2
Cleared 510(K)
K
24
2329
CT Collaboration Live
2
Cleared 510(K)
K
24
2062
1CMR Pro
2
Cleared 510(K)
K
24
1981
Change Healthcare Stratus Imaging PACS
2
Cleared 510(K)
K
24
2709
JLK-PWI
2
Cleared 510(K)
K
24
1223
eRAD PACS
2
Cleared 510(K)
K
24
2512
ROCC Console
2
Cleared 510(K)
K
24
3012
MIM – Symphony HDR Fusion
2
Cleared 510(K)
K
24
3209
nordicMEDiVA
2
Cleared 510(K)
K
24
2556
JLK-CTP
2
Cleared 510(K)
K
24
0385
VINT
2
Cleared 510(K)
K
24
1569
syngo Application Software
2
Cleared 510(K)
K
24
0243
EConsole2
2
Cleared 510(K)
K
24
1524
Elucid PlaqueIQ
2
Cleared 510(K)
K
23
3998
TRAQinform IQ
2
Cleared 510(K)
K
24
1302
SonoSync
2
Cleared 510(K)
K
24
0290
AiMIFY (1.x)
2
Cleared 510(K)
K
24
1094
Bullsai
2
Cleared 510(K)
K
24
0724
SynthVISION 1.0.0
2
Cleared 510(K)
K
23
3761
Orthopaedic Surgery Planning Software (AIJOINT)
2
Cleared 510(K)
K
24
1114
EzDent-i / E2 / Prora View / Smart M Viewer (v3.5)
2
Cleared 510(K)
K
24
1879
vRad Viewer
2
Cleared 510(K)
K
24
1121
MICSI-RMT
2
Cleared 510(K)
K
24
0705
Vitrea Software Package, VSTP-002A V2.0
2
Cleared 510(K)
K
24
1300
ViewPoint 6
2
Cleared 510(K)
K
23
3908
cNeuro cDAT
2
Cleared 510(K)
K
24
1608
nordicMEDiVA
2
Cleared 510(K)
K
23
3331
MediOMx
2
Cleared 510(K)
K
24
0281
Bone Suppression Software
2
Cleared 510(K)
K
22
3427
Mimics Enlight CMF
2
Cleared 510(K)
K
24
0294
Syngo Carbon Enterprise Access (VA40A)
2
Cleared 510(K)
K
23
2759
Viewer (5.4); Elements Viewer; Mixed Reality Viewer; Smart Layout; Elements Viewer Smart Layout
2
Cleared 510(K)
K
23
3620
MIM - Centiloid Scaling
2
Cleared 510(K)
K
23
2862
MIM – Monte Carlo Dosimetry
2
Cleared 510(K)
K
23
2976
VUZE System
2
Cleared 510(K)
K
23
2514
MIM – Dose Analysis
2
Cleared 510(K)
K
23
3699
SubtleREFORMAT (1.x)
2
Cleared 510(K)
K
24
0839
OpenRad Cloud
2
Cleared 510(K)
K
24
0822
Image Management V15
2
Cleared 510(K)
K
23
3582
Rapid
2
Cleared 510(K)
K
23
2641
Neorad Pacs (Neorad Pacs)
2
Cleared 510(K)
K
23
2891
CARPL (CARPL)
2
Cleared 510(K)
K
24
0620
Cube Navigator
2
Cleared 510(K)
K
23
3660
nCommand Lite System
2
Cleared 510(K)
K
23
3599
X-Clever (ASHK100G)
2
Cleared 510(K)
K
23
3930
MRCP+ version 2 (MRCP+ v2)
2
Cleared 510(K)
K
23
3572
Autofuse
2
Cleared 510(K)
K
23
3217
Mimics Cardiac Planner
2
Cleared 510(K)
K
23
1662
Aid-U
2
Cleared 510(K)
K
23
2339
Augmented Reality Application
2
Cleared 510(K)
K
23
2007
CAAS MR Solutions
2
Cleared 510(K)
K
23
1396
CEPHX- Cephalometric Analysis Software
2
Cleared 510(K)
K
23
3714
BreView
2
Cleared 510(K)
K
23
1607
Axial3D Cloud Segmentation Service
2
Cleared 510(K)
K
23
3226
FlexView Diagnostic (v1.1.20)
2
Cleared 510(K)
K
23
2589
Horos MD™
2
Cleared 510(K)
K
23
2744
syngo Virtual Cockpit (VB10A)
2
Cleared 510(K)
K
23
3176
uOmnispace.MI
2
Cleared 510(K)
K
23
0955
syngo Application Software
2
Cleared 510(K)
K
23
1570
StrokeViewer Perfusion
2
Cleared 510(K)
K
23
3634
TeleScan
2
Cleared 510(K)
K
23
1898
DTX Studio Clinic (4.0)
2
Cleared 510(K)
K
23
2661
Myocardial Strain Software Application
2
Cleared 510(K)
K
23
1498
TraumaCad Neo
2
Cleared 510(K)
K
23
0856
BrainSpec Core™ Software
2
Cleared 510(K)
K
23
0854
SwiftMR
2
Cleared 510(K)
K
23
2086
spineEOS
2
Cleared 510(K)
K
22
3909
R2GATE Lite TM
2
Cleared 510(K)
K
23
1225
EConsole1
2
Cleared 510(K)
K
23
0249
Ikshana
2
Cleared 510(K)
K
23
1642
Veuron-Brain-pAb3
2
Cleared 510(K)
K
23
0252
OFIX MIS App
2
Cleared 510(K)
K
22
3659
Jazz
2
Cleared 510(K)
K
23
1385
Rology Teleradiology Platform (v.1.22.1103)
2
Cleared 510(K)
K
23
2189
OrionXR
2
Cleared 510(K)
K
23
1353
AccuCTP Pro
2
Cleared 510(K)
K
22
0034
NEUROShield
2
Cleared 510(K)
K
23
1047
UniSyn Molecular Imaging (6-3-1)
2
Cleared 510(K)
K
23
1656
Brainomix 360 e-MRI
2
Cleared 510(K)
K
22
3180
AIRAscore
2
Cleared 510(K)
K
23
1503
CUPTIMIZE™ Advanced
2
Cleared 510(K)
K
22
3660
SaintView
2
Cleared 510(K)
K
23
2100
Efai Pacs Picture Archiving and Communication System Pro
2
Cleared 510(K)
K
23
0540
Patient Specific Planning Solution™ 3D Bone Models
2
Cleared 510(K)
K
22
3322
Argus Cognitive ReVISION Software
2
Cleared 510(K)
K
22
2683
Fibroid Mapping Reviewer Application (FMRA)
2
Cleared 510(K)
K
23
1041
JiveX (Model Number / Release: 5.4)
2
Cleared 510(K)
K
23
0016
Cercare Medical Neurosuite
2
Cleared 510(K)
K
22
3290
CommandEP Data Manager PC (DPC02), CommandEP HMD (HMD02)
2
Cleared 510(K)
K
23
1351
Chondral Quant
2
Cleared 510(K)
K
22
3125
XR90 (XR90-SYS)
2
Cleared 510(K)
K
21
3253
Pixyl.Neuro
2
Cleared 510(K)
K
22
3048
Medisystem Pacs
2
Cleared 510(K)
K
22
3091
CT Perfusion V1.0
2
Cleared 510(K)
K
23
1360
Ambra PACS
2
Cleared 510(K)
K
22
3532
Olea S.I.A. Neurovascular V1.0
2
Cleared 510(K)
K
22
3555
Brainomix 360 e-CTP
2
Cleared 510(K)
K
22
3841
KBA3D
2
Cleared 510(K)
K
22
2359
Quicktome Software Suite
2
Cleared 510(K)
K
23
0044
Pre-Sure
2
Cleared 510(K)
K
22
2035
Avatar Medical Software V1
2
Cleared 510(K)
K
23
1162
ROSA Hip System
2
Cleared 510(K)
K
23
0803
ADAS 3D
2
Cleared 510(K)
K
21
2758
Autoplaque
2
Cleared 510(K)
K
22
2854
iTFlow
2
Cleared 510(K)
K
22
3623
SubtleMR (2.3.x)
2
Cleared 510(K)
K
22
2987
Akunah REFLECT
2
Cleared 510(K)
K
22
0437
Neurophet AQUA
2
Cleared 510(K)
K
23
0119
3D Anatomic Model
2
Cleared 510(K)
K
22
1870
CarnaLife Holo
2
Cleared 510(K)
K
23
0552
MR DWI/FLAIR Measurement V1.0
2
Cleared 510(K)
K
23
0906
Konicaminolta DI-X1
2
Cleared 510(K)
K
23
0468
EzDent Web
2
Cleared 510(K)
K
23
0772
Quantib Prostate
2
Cleared 510(K)
K
23
0393
UniCam Evo Software
2
Cleared 510(K)
K
23
0264
Ezra Flash
2
Cleared 510(K)
K
22
2781
Augmento
2
Cleared 510(K)
K
23
0575
Limbus Contour
2
Cleared 510(K)
K
21
3660
RadAlly
2
Cleared 510(K)
K
21
1059
CereFlow™ V1.2
2
Cleared 510(K)
K
22
1984
InterView XP; InterView FUSION
2
Cleared 510(K)
K
23
0561
Syngo Carbon Space VA30A
2
Cleared 510(K)
K
22
3490
FlightPlan for Embolization
2
Cleared 510(K)
K
23
0294
CoverScan (CoverScan v1.1)
2
Cleared 510(K)
K
22
2975
Advantis Platform
2
Cleared 510(K)
K
22
1680
Xeleris V Processing and Review System
2
Cleared 510(K)
K
22
2757
Clarus Viewer
2
Cleared 510(K)
K
21
3891
RealNow
2
Cleared 510(K)
K
22
3820
EzDent-i / E2 / Prora View/ Smart M Viewer
2
Cleared 510(K)
K
23
0196
syngo.via View&GO VA40A
2
Cleared 510(K)
K
22
3425
MD.ai Viewer
2
Cleared 510(K)
K
23
0012
Atomica Planner
2
Cleared 510(K)
K
22
1725
Advanced MyHip Planner
2
Cleared 510(K)
K
22
1627
PerfusionGo Plus
2
Cleared 510(K)
K
22
2593
TruPlan Computed Tomography (CT) Imaging Software
2
Cleared 510(K)
K
22
3800
MIM – Additional Tracers
2
Cleared 510(K)
K
22
0649
Elucis
2
Cleared 510(K)
K
22
3502
MR Diffusion Perfusion Mismatch V1.0
2
Cleared 510(K)
K
22
3363
MAMMOVISTA B.smart (VB70)
2
Cleared 510(K)
K
22
2458
AIBOLIT 3D+
2
Cleared 510(K)
K
22
3336
Vitrea Software Package, VSTP-002A
2
Cleared 510(K)
K
22
2577
TECHFIT Diagnostic Models
2
Cleared 510(K)
K
21
3263
OnyxCeph
2
Cleared 510(K)
K
22
2767
PeekMed web (v1)
2
Cleared 510(K)
K
22
2195
aprevo® Digital Workflow
2
Cleared 510(K)
K
22
1796
Cyware 4H and Cysart 4H
2
Cleared 510(K)
K
22
3071
Xenoview VDP
2
Cleared 510(K)
K
22
2320
MedDream
2
Cleared 510(K)
K
22
0630
TorchTM Software
2
Cleared 510(K)
K
21
3215
VSI HoloMedicine
2
Cleared 510(K)
K
22
3152
Vision 2, EVARVision, TrackVision 2, HeartVision 2
2
Cleared 510(K)
K
22
2054
Denti.AI Auto-Chart
2
Cleared 510(K)
K
22
1499
Minimally Invasive Prostate Surgery Navigation System
2
Cleared 510(K)
K
22
0663
AccuCTP
2
Cleared 510(K)
K
22
2476
OmegaAI Image Viewer
2
Cleared 510(K)
K
22
1677
Synapse 3D Base Tools v6.6
2
Cleared 510(K)
K
22
1478
Dolphin Blue Imaging
2
Cleared 510(K)
K
22
2470
3Dicom MD
2
Cleared 510(K)
K
21
3128
IntraOp VSP Software Device
2
Cleared 510(K)
K
22
2662
Vitrea CT Cardiac Analysis
2
Cleared 510(K)
K
22
1501
syngo.via View&GO
2
Cleared 510(K)
K
22
0758
e-Ortho Shoulder Software v1.1
2
Cleared 510(K)
K
22
2069
Ez3D-i/E3
2
Cleared 510(K)
K
21
3520
AXIR-CX
2
Cleared 510(K)
K
22
0903
WebCeph
2
Cleared 510(K)
K
22
0433
syngo Application Software (VE21)
2
Cleared 510(K)
K
22
2145
EzDent-i / E2 / Prora View/ Smart M Viewer
2
Cleared 510(K)
K
22
0349
TeraRecon Neuro
2
Cleared 510(K)
K
22
2072
Dolphin Imaging 12.0
2
Cleared 510(K)
K
22
1405
Neurophet SCALE PET
2
Cleared 510(K)
K
22
0733
OptiVu ROSA MxR
2
Cleared 510(K)
K
22
0624
AI4CMR v1.0
2
Cleared 510(K)
K
21
3922
FX SPS
2
Cleared 510(K)
K
22
0039
AutoSeg
2
Cleared 510(K)
K
22
1426
Functional MR V1.0
2
Cleared 510(K)
K
22
1511
Axial3D Cloud Segmentation Service
2
Cleared 510(K)
K
21
3665
Syngo Carbon Space VA20A
2
Cleared 510(K)
K
22
1463
ElucidVivo A.3
2
Cleared 510(K)
K
21
3684
SurgiCase Viewer
2
Cleared 510(K)
K
22
1065
MediLab
2
Cleared 510(K)
K
22
0205
3D Anatomic Models
2
Cleared 510(K)
K
22
1270
EchoNavigator R4.0
2
Cleared 510(K)
K
22
0416
SwiftMR
2
Cleared 510(K)
K
22
1000
ON3D
2
Cleared 510(K)
K
22
0832
syngo Dynamics (Version VA40E)
2
Cleared 510(K)
K
21
2565
CoverScan v1
2
Cleared 510(K)
K
21
2376
Caas Qardia
2
Cleared 510(K)
K
22
1106
Quantib Prostate
2
Cleared 510(K)
K
22
0727
inHEART MODELS
2
Cleared 510(K)
K
21
3975
KEOPS Balance Analyzer 3D
2
Cleared 510(K)
K
21
1966
Segment 3DPrint
2
Cleared 510(K)
K
21
3302
exoplan
2
Cleared 510(K)
K
22
0684
Oryx Cloud Imaging
2
Cleared 510(K)
K
22
0590
aPROMISE X
2
Cleared 510(K)
K
21
1713
AngioCloud Service
2
Cleared 510(K)
K
21
2981
MirrorMe3D Modeling System
2
Cleared 510(K)
K
22
0779
XD
2
Cleared 510(K)
K
22
0767
TeleScan
2
Cleared 510(K)
K
20
3783
ClariPulmo
2
Cleared 510(K)
K
21
3562
DTX Studio Clinic 3.0
2
Cleared 510(K)
K
21
2040
RI.HIP MODELER
2
Cleared 510(K)
K
21
2720
nordicDSC
2
Cleared 510(K)
K
22
0003
EzOrtho v1.3
2
Cleared 510(K)
K
21
3165
Rapid
2
Cleared 510(K)
K
21
3801
Veuron-Brain-pAb2
2
Cleared 510(K)
K
21
3737
Quantib ND
2
Cleared 510(K)
K
21
2005
UNiD Spine Analyzer
2
Cleared 510(K)
K
21
1443
AIBOLIT 3D+
2
Cleared 510(K)
K
21
0830
VUZE System
2
Cleared 510(K)
K
21
1156
CONVIVO In Vivo Pathology Suite
2
Cleared 510(K)
K
21
3140
Claritas iPET
2
Cleared 510(K)
K
21
0931
Libby IAAA v1.0
2
Cleared 510(K)
K
21
2420
Brainlab Elements, Brainlab Elements Contouring, Brainlab Elements Fibertracking, Brainlab Elements Image Fusion, Brainlab Elements Image Fusion Angio
2
Cleared 510(K)
K
21
1114
Will3D
2
Cleared 510(K)
K
21
1039
BIT-Motion
2
Cleared 510(K)
K
21
2137
X-Clever
2
Cleared 510(K)
K
20
3743
EXA
2
Cleared 510(K)
K
21
0916
PVmed Contouring Software
2
Cleared 510(K)
K
21
0241
ImplaStation
2
Cleared 510(K)
K
21
1432
Myomics Q
2
Cleared 510(K)
K
21
2984
MiPACS HTML5 Web Viewer
2
Cleared 510(K)
K
21
2621
MAMMOVISTA B.smart
2
Cleared 510(K)
K
21
1876
Intellijoint VIEW
2
Cleared 510(K)
K
21
2887
RTapp
2
Cleared 510(K)
K
21
0344
inVisionOS
2
Cleared 510(K)
K
21
2550
Hura CTP v1.0
2
Cleared 510(K)
K
21
1356
GIQuant
2
Cleared 510(K)
K
21
2896
Visible Patient Suite
2
Cleared 510(K)
K
21
3326
VisionX 3.0
2
Cleared 510(K)
K
21
1987
ATEC Alignment App
2
Cleared 510(K)
K
21
0807
FlightPlan for Liver
2
Cleared 510(K)
K
21
2470
iRAD
2
Cleared 510(K)
K
21
2528
Change Healthcare Cardiology
2
Cleared 510(K)
K
21
0999
SwiftMR
2
Cleared 510(K)
K
20
2808
Brainance MD
2
Cleared 510(K)
K
21
1429
NAVIPLAN - CT Planning Software for Total Hip Replacement
2
Cleared 510(K)
K
21
1795
EzDent-i/ E2/ Prora View/ Smart M Viewer
2
Cleared 510(K)
K
21
0726
ImmersiveTouch
2
Cleared 510(K)
K
21
1700
EzDent Web
2
Cleared 510(K)
K
21
2777
Collaboration Live
2
Cleared 510(K)
K
21
2321
JiveX (Model Number / Release: 5.3)
2
Cleared 510(K)
K
21
2685
KONICAMINOLTA DI-X1
2
Cleared 510(K)
K
21
1257
EFAI PACS Picture Archiving and Communication System
2
Cleared 510(K)
K
20
2056
Kinepict Medical Imaging Tool 4.0
2
Cleared 510(K)
K
21
2421
ADAS 3D
2
Cleared 510(K)
K
20
3696
RBknee
2
Cleared 510(K)
K
21
1793
EzOrtho
2
Cleared 510(K)
K
21
1791
Ez3D-i/E3
2
Cleared 510(K)
K
21
0998
ROSA Hip System
2
Cleared 510(K)
K
20
1573
Brain Perfusion (BP) application
2
Cleared 510(K)
K
21
2230
TruSPECT Radiological Image Processing Station
2
Cleared 510(K)
K
21
1863
eVolve PACS
2
Cleared 510(K)
K
21
2175
DynaCAD
2
Cleared 510(K)
K
21
2074
ClariCT.AI
2
Cleared 510(K)
K
21
1655
aPROMISE
2
Cleared 510(K)
K
21
1279
Volpara Imaging Software
2
Cleared 510(K)
K
21
1386
MySpine WebPlanner & MyBalance
2
Cleared 510(K)
K
20
3765
ZIRKONZAHN.Implant-Planner, ZIRKONZAHN.Implant-Planner Practice, CAD/CAM STL Converter, CAD/CAM Z-Tray
2
Cleared 510(K)
K
21
1480
NubeX
2
Cleared 510(K)
K
20
1835
PRE-SURE
2
Cleared 510(K)
K
21
0653
ONE Planner Hip
2
Cleared 510(K)
K
21
1656
3D Echo v1.1
2
Cleared 510(K)
K
20
2718
Qmenta Care Platform Family
2
Cleared 510(K)
K
20
0704
ZedView
2
Cleared 510(K)
K
21
1312
Universal Viewer
2
Cleared 510(K)
K
21
0257
Xoran Workstation, Model 10050
2
Cleared 510(K)
K
21
0187
Overjet Dental Assist
2
Cleared 510(K)
K
20
2793
Cercare Medical Neurosuite
2
Cleared 510(K)
K
21
0072
HOLOSCOPE-i
2
Cleared 510(K)
K
21
0066
ImagePilot
2
Cleared 510(K)
K
21
0682
SOTA Cloud Imaging
2
Cleared 510(K)
K
20
2521
PtoleMedic System
2
Cleared 510(K)
K
20
2084
DeepLook PRECISE
2
Cleared 510(K)
K
21
0850
ADAS 3D
2
Cleared 510(K)
K
20
3195
Simpleware ScanIP Medical
2
Cleared 510(K)
K
21
0071
SIS System (Version 5.1.0)
2
Cleared 510(K)
K
20
3518
Quicktome
2
Cleared 510(K)
K
20
3651
Cuptimize
2
Cleared 510(K)
K
20
3182
SubtleMR
2
Cleared 510(K)
K
20
2990
NinesMeasure
2
Cleared 510(K)
K
20
2212
TruPlan
2
Cleared 510(K)
K
20
0589
MyPAO Planning Report
2
Cleared 510(K)
K
21
0136
PhantomMSK Hip
2
Cleared 510(K)
K
20
3312
Vitrea Software Package, VSTP-001A
2
Cleared 510(K)
K
20
3103
Synapse 3D, Synapse 3D Base Tools v6.1
2
Cleared 510(K)
K
20
3290
Bonelogic
2
Cleared 510(K)
K
20
3582
QUIBIM Precision Prostate (qp-Prostate)
2
Cleared 510(K)
K
20
3104
IBM iConnect Access
2
Cleared 510(K)
K
20
3677
ViewPoint 6
2
Cleared 510(K)
K
20
3142
Veuron-Brain-pAb
2
Cleared 510(K)
K
20
2847
AccuBrain
2
Cleared 510(K)
K
20
2414
BrainInsight
2
Cleared 510(K)
K
20
2229
AI Metrics
2
Cleared 510(K)
K
20
1250
SQuEEZ Software
2
Cleared 510(K)
K
20
3249
Nucleus.io
2
Cleared 510(K)
K
20
2487
HealthJOINT
2
Cleared 510(K)
K
20
0572
Planmeca Romexis
2
Cleared 510(K)
K
20
3156
DTX Studio Clinic
2
Cleared 510(K)
K
20
2805
Optimized Positioning System (OPS) Insight
2
Cleared 510(K)
K
19
3287
CorInsights MRI
2
Cleared 510(K)
K
20
3287
DBSWIN, VISTAEASY
2
Cleared 510(K)
K
19
3306
PROView
2
Cleared 510(K)
K
20
0750
Neuro.Al Algorithm
2
Cleared 510(K)
K
20
0350
MyHip Planner & Verifier
2
Cleared 510(K)
K
20
3058
CloudVue
2
Cleared 510(K)
K
20
2519
OrthoNext Platform System
2
Cleared 510(K)
K
20
2948
EzOrtho
2
Cleared 510(K)
K
20
1710
A View LCS
2
Cleared 510(K)
K
20
2501
Quantib Prostate
2
Cleared 510(K)
K
20
0810
IPS CaseDesigner
2
Cleared 510(K)
K
20
2292
UDE
2
Cleared 510(K)
K
20
2280
Cleerly Labs v2.0
2
Cleared 510(K)
K
20
1928
e-Ortho Shoulder Software
2
Cleared 510(K)
K
19
2051
THINQ
2
Cleared 510(K)
K
20
1103
Xeleris V Processing and Review Systems
2
Cleared 510(K)
K
20
0603
AAA Model
2
Cleared 510(K)
K
20
0852
EchoPAC Software Only, EchoPAC Plug-In
2
Cleared 510(K)
K
19
2890
SentEP
2
Cleared 510(K)
K
20
1369
AVA (Augmented Vascular Analysis)
2
Cleared 510(K)
K
20
1665
Collaboration Live
2
Cleared 510(K)
K
20
2297
Aline Ablation Intelligence
2
Cleared 510(K)
K
20
2256
3Shape Implant Studio
2
Cleared 510(K)
K
20
1948
AcroDTI Visualizer
2
Cleared 510(K)
K
20
2335
Ambra ProViewer
2
Cleared 510(K)
K
20
0973
Synapse 3D Cardiac Tools
2
Cleared 510(K)
K
20
0714
AVIEW
2
Cleared 510(K)
K
20
2116
EzDent-i/ E2/ Prora View/ Smart M Viewer
2
Cleared 510(K)
K
20
1352
3D Auto LAA
2
Cleared 510(K)
K
20
1632
TOMTEC-ARENA
2
Cleared 510(K)
K
20
1232
Limbus Contour
2
Cleared 510(K)
K
20
0822
Braid
2
Cleared 510(K)
K
20
1465
SuRgical Planner (SRP) BrainStorm
2
Cleared 510(K)
K
20
1365
True 3D Viewer
2
Cleared 510(K)
K
19
3294
AI-Rad Companion Engine
2
Cleared 510(K)
K
20
1296
i-Rapha Solution
2
Cleared 510(K)
K
20
1477
syngo.via View&GO
2
Cleared 510(K)
K
19
3042
Optimized Positioning System (OPS) ReView
2
Cleared 510(K)
K
19
3290
AI-Rad Companion Brain MR
2
Cleared 510(K)
K
20
0899
Quantib AI Node
2
Cleared 510(K)
K
19
2630
uWS-MI
2
Cleared 510(K)
K
20
1202
MI View&GO
2
Cleared 510(K)
K
19
2692
Brainomix 360 e-CTA
2
Cleared 510(K)
K
20
0274
CariCloud
2
Cleared 510(K)
K
20
1062
syngo Ultrasound Apps Suite (sUSAS)
2
Cleared 510(K)
K
20
0546
ZeeroMED View
2
Cleared 510(K)
K
20
0315
Ziostation2
2
Cleared 510(K)
K
19
3220
AVIEW LCS
2
Cleared 510(K)
K
19
2656
Optimized Positioning System (OPS) Insight
2
Cleared 510(K)
K
19
3523
ArthrexVIP Web Portal
2
Cleared 510(K)
K
19
2475
NemoFAB
2
Cleared 510(K)
K
20
0703
JiveX
2
Cleared 510(K)
K
19
3369
Xelis Dental 2.0
2
Cleared 510(K)
K
20
0078
VARO Plan
2
Cleared 510(K)
K
20
0713
EchoNavigator
2
Cleared 510(K)
K
19
2176
IntelePACS
2
Cleared 510(K)
K
19
0767
AnatomicAligner
2
Cleared 510(K)
K
19
2888
EzOrtho
2
Cleared 510(K)
K
19
0993
Kinepict Medical Imaging Tool version v2.2
2
Cleared 510(K)
K
19
2962
icobrain-ctp
2
Cleared 510(K)
K
20
0178
Ez3D-i /E3
2
Cleared 510(K)
K
19
2973
densitas densityai
2
Cleared 510(K)
K
20
0179
Collaboration Live
2
Cleared 510(K)
K
20
0132
Ashvins
2
Cleared 510(K)
K
19
2923
Vitrea Software Package
2
Cleared 510(K)
K
19
2372
ASCEND Image Viewer
2
Cleared 510(K)
K
19
3498
Infinitt RT PACS
2
Cleared 510(K)
K
19
2165
Acteon Imaging Suite
2
Cleared 510(K)
K
19
2462
syngo.MR Applications
2
Cleared 510(K)
K
19
3261
FlightPlan for Embolization
2
Cleared 510(K)
K
19
1014
Elements Viewer
2
Cleared 510(K)
K
19
2098
EzMobile
2
Cleared 510(K)
K
19
1125
ADAS 3D
2
Cleared 510(K)
K
19
2917
ViewPoint 6
2
Cleared 510(K)
K
19
2912
AutoMIStar
2
Cleared 510(K)
K
19
3403
UroNav System
2
Cleared 510(K)
K
19
3149
True 3D Viewer Software
2
Cleared 510(K)
K
19
2040
AVIEW Modeler
2
Cleared 510(K)
K
18
3676
DentiqAir
2
Cleared 510(K)
K
19
2531
QyScore Software
2
Cleared 510(K)
K
19
2130
Icobrain
2
Cleared 510(K)
K
19
2571
NemoScan
2
Cleared 510(K)
K
19
2279
PhantomMSK Trauma
2
Cleared 510(K)
K
19
2348
SICAT Implant V2.0
2
Cleared 510(K)
K
19
2038
Emprint Visualization Application
2
Cleared 510(K)
K
19
2508
Medsynapse Ris Pacs & Medsynapse VNA
2
Cleared 510(K)
K
19
1278
RSI-MRI+
2
Cleared 510(K)
K
19
1959
QuantX Breast MRI Biopsy Guidance Plugin
2
Cleared 510(K)
K
19
1026
MEDIP PRO
2
Cleared 510(K)
K
19
2109
KOALA
2
Cleared 510(K)
K
19
0868
Cleerly Labs
2
Cleared 510(K)
K
19
2743
VisionX 2.4
2
Cleared 510(K)
K
18
3412
mediCAD Web
2
Cleared 510(K)
K
19
1544
Synapse 3D Blood Flow Analysis
2
Cleared 510(K)
K
19
2455
Merge PACS
2
Cleared 510(K)
K
19
1216
Voxel Dosimetry™ v1.0
2
Cleared 510(K)
K
19
0162
SmartCeph
2
Cleared 510(K)
K
19
1493
Ventripoint Medical System Plus (VMS+) 3.0
2
Cleared 510(K)
K
19
2200
DynaCAD
2
Cleared 510(K)
K
19
1610
RTapp
2
Cleared 510(K)
K
19
2435
NuVasive NuvaLine
2
Cleared 510(K)
K
19
1530
StoneChecker
2
Cleared 510(K)
K
19
2276
Merge Cardio
2
Cleared 510(K)
K
19
1688
SubtleMR
2
Cleared 510(K)
K
19
2304
SIS Software Version 3.6.0
2
Cleared 510(K)
K
19
0780
syngo Application Software
2
Cleared 510(K)
K
18
3489
D2P
2
Cleared 510(K)
K
18
3544
Efficient Care 3D Planning
2
Cleared 510(K)
K
18
3458
exoplan 2.3
2
Cleared 510(K)
K
19
1262
aBSI
2
Cleared 510(K)
K
18
3193
MREplus+ Software
2
Cleared 510(K)
K
19
1309
syngo.via MI Workflows VB40A, Scenium
2
Cleared 510(K)
K
19
1585
iNtuition-Structural Heart Module
2
Cleared 510(K)
K
19
0694
Unifi Workspace v1.0.0
2
Cleared 510(K)
K
18
2904
syngo.MR Applications
2
Cleared 510(K)
K
19
0096
R2GATE
2
Cleared 510(K)
K
18
3170
uWS-CT
2
Cleared 510(K)
K
19
0913
QLAB Advanced Quantification Software 13
2
Cleared 510(K)
K
18
3460
ClariCT.AI
2
Cleared 510(K)
K
19
0874
Materialise Mimics Enlight
2
Cleared 510(K)
K
19
1188
ASHK100G
2
Cleared 510(K)
K
19
1040
syngo.via (Version VB40A)
2
Cleared 510(K)
K
19
0764
SurgicalAR
2
Cleared 510(K)
K
19
0866
XmaruView V1 (Xmaru Chiroview, Xmaru Podview)
2
Cleared 510(K)
K
19
0042
Brainlab Elements Image Fusion Angio
2
Cleared 510(K)
K
18
3248
Synapse Enterprise Viewer Version 1.0
2
Cleared 510(K)
K
19
0791
Ez3D-i/E3
2
Cleared 510(K)
K
18
3593
Lung Vision System
2
Cleared 510(K)
K
19
0420
NDOHD High Definition Imaging System (NDOHD)
2
Cleared 510(K)
K
18
2572
InstaRISPACS / InstaZFP / InstaMobi v5.0
2
Cleared 510(K)
K
19
0629
DBSWIN and VISTAEASY Imaging Software
2
Cleared 510(K)
K
18
3210
Thoracic VCAR with GSI Pulmonary Perfusion
2
Cleared 510(K)
K
18
3105
Mimics Medical
2
Cleared 510(K)
K
19
0232
Synapse PACS
2
Cleared 510(K)
K
18
3164
uWS-MR
2
Cleared 510(K)
K
19
0379
MIM on Linux
2
Cleared 510(K)
K
18
3019
SIS Software version 3.3.0
2
Cleared 510(K)
K
18
2537
RADMAX Digital Imaging Software
2
Cleared 510(K)
K
18
2966
PLANET Onco Dose
2
Cleared 510(K)
K
18
1859
Visualase Thermal Therapy System
2
Cleared 510(K)
K
18
3478
ClearON Mobile
2
Cleared 510(K)
K
19
0087
EzDent-i / E2 / Prora View
2
Cleared 510(K)
K
18
2643
IRIS 1.0 System
2
Cleared 510(K)
K
18
2332
PhantomMSK
2
Cleared 510(K)
K
19
0074
Presero 3D Scanning System
2
Cleared 510(K)
K
18
3272
AI Rad Companion (Engine)
2
Cleared 510(K)
K
18
3133
MRCP+ v1.0
2
Cleared 510(K)
K
18
2855
ProKnow DS
2
Cleared 510(K)
K
18
0867
AmCAD-UO
2
Cleared 510(K)
K
18
2564
Quantib ND
2
Cleared 510(K)
K
18
2130
iSchemaView RAPID
2
Cleared 510(K)
K
18
3012
vascuCAP
2
Cleared 510(K)
K
18
2750
4D View
2
Cleared 510(K)
K
17
3041
3DIEMME RealGUIDE
2
Cleared 510(K)
K
18
2624
MIM - MRT Dosimetry
2
Cleared 510(K)
K
18
2601
Vitrea Software Package, VSTP-001A
2
Cleared 510(K)
K
18
2419
Centricity Universal Viewer
2
Cleared 510(K)
K
18
2359
HipCheck
2
Cleared 510(K)
K
18
2926
IntelliSpace Radiology
2
Cleared 510(K)
K
18
2016
Simplicit90Y
2
Cleared 510(K)
K
18
1825
CAAS MR Solutions
2
Cleared 510(K)
K
17
3083
IMPLANTER DENTAL PLANNING SOFTWARE
2
Cleared 510(K)
K
18
2815
XVWeb 3D
2
Cleared 510(K)
K
18
3038
Corin Optimized Positioning System (OPS) Plan
2
Cleared 510(K)
K
18
3013
Vitrea Software Package, VSTP-001A
2
Cleared 510(K)
K
18
2431
Konicaminolta DI-X1
2
Cleared 510(K)
K
17
3744
ProFuse CAD
2
Cleared 510(K)
K
18
1247
Vitrea CT Brain Perfusion
2
Cleared 510(K)
K
17
2999
uWS-MR
2
Cleared 510(K)
K
17
3001
uWS-CT
2
Cleared 510(K)
K
18
1939
icobrain
2
Cleared 510(K)
K
17
1199
AVIEW
2
Cleared 510(K)
K
17
3965
Implant Planning Software
2
Cleared 510(K)
K
18
2464
PeekMed
2
Cleared 510(K)
K
18
1964
JiveX
2
Cleared 510(K)
K
18
2561
UroNav (Version 3.0)
2
Cleared 510(K)
K
18
2034
Arterys MICA
2
Cleared 510(K)
K
18
1460
OnePacs System
2
Cleared 510(K)
K
18
1892
Ziostation2
2
Cleared 510(K)
K
18
2290
IBM iConnect Access
2
Cleared 510(K)
K
18
1773
Synapse 3D Optional Tools
2
Cleared 510(K)
K
18
0916
iNtuition-T1 Mapping and T2/T2* Mapping
2
Cleared 510(K)
K
18
2310
Volpara Imaging Software
2
Cleared 510(K)
K
18
1926
InVivo Web Viewer
2
Cleared 510(K)
K
17
2418
OpenSight
2
Cleared 510(K)
K
18
2230
Multi Modality Viewer
2
Cleared 510(K)
K
18
2208
syngo.via View&GO (Version VA10A)
2
Cleared 510(K)
K
17
0702
mediCAD 4.0
2
Cleared 510(K)
K
18
0006
AmCAD-UT Detection 2.2
2
Cleared 510(K)
K
18
1185
Change Healthcare Enterprise Viewer
2
Cleared 510(K)
K
18
0522
IGTFusion
2
Cleared 510(K)
K
18
1318
ONIS-PACS
2
Cleared 510(K)
K
18
1962
CubeVue
2
Cleared 510(K)
K
17
1435
VirtuOst Vertebral Fracture Assessment
2
Cleared 510(K)
K
17
1977
miPlatform medical imaging suite v3.0 (miPlatform v3.0), miPlatform ZFP Viewer
2
Cleared 510(K)
K
17
3444
Quantitative Total Extensible Imaging (QTxI)
2
Cleared 510(K)
K
18
0629
DentiqGuide
2
Cleared 510(K)
K
17
3274
Ceevra Reveal 2.0
2
Cleared 510(K)
K
17
3574
DenSeeMammo
2
Cleared 510(K)
K
18
0815
MIM - SPECTRA Quant
2
Cleared 510(K)
K
17
2346
sterEOS Workstation
2
Cleared 510(K)
K
18
1290
Fusion Bx 2.0
2
Cleared 510(K)
K
17
3780
EchoMD Automated Ejection Fraction Software
2
Cleared 510(K)
K
18
1264
QLAB Advanced Quantification Software
2
Cleared 510(K)
K
18
1177
Interventional Workspot
2
Cleared 510(K)
K
18
1080
McKesson Cardiology
2
Cleared 510(K)
K
18
0883
5D Viewer
2
Cleared 510(K)
K
18
0641
Invenia ABUS Viewer
2
Cleared 510(K)
K
17
3390
hipEOS
2
Cleared 510(K)
K
18
0563
syngo.plaza
2
Cleared 510(K)
K
17
2768
ZOOM
2
Cleared 510(K)
K
18
0161
Viz CTP
2
Cleared 510(K)
K
18
0336
syngo.MR Applications
2
Cleared 510(K)
K
17
2477
iSchemaView RAPID
2
Cleared 510(K)
K
18
0549
ZED Link
2
Cleared 510(K)
K
18
0125
PowerLook Density Assessment Software
2
Cleared 510(K)
K
17
3897
syngo.via MI Workflows
2
Cleared 510(K)
K
17
2998
uWS-MI
2
Cleared 510(K)
K
17
1847
Corin Optimized Positioning System (OPS™) Plan
2
Cleared 510(K)
K
17
3597
Scenium VE20 Software
2
Cleared 510(K)
K
17
2239
SIMPLANT 18
2
Cleared 510(K)
K
18
0323
Vitrea Software Package; VSTP-001A
2
Cleared 510(K)
K
17
3241
MED-TAB
2
Cleared 510(K)
K
18
0192
Emprint Ablation Visualization Application
2
Cleared 510(K)
K
17
3619
Mimics inPrint
2
Cleared 510(K)
K
17
2168
WillCeph
2
Cleared 510(K)
K
18
0129
Imbio Segmentation Editing Tool software
2
Cleared 510(K)
K
17
3611
syngo Application Software
2
Cleared 510(K)
K
18
0262
SICAT Endo
2
Cleared 510(K)
K
18
0394
BrightMatter Plan 1.6.0
2
Cleared 510(K)
K
17
3939
Quantib Brain
2
Cleared 510(K)
K
18
0326
icobrain
2
Cleared 510(K)
K
17
3605
iQMR
2
Cleared 510(K)
K
17
3312
ProBx Software
2
Cleared 510(K)
K
17
3145
CereMetrix Silver
2
Cleared 510(K)
K
17
3863
Ez3D-i /E3
2
Cleared 510(K)
K
17
0540
DM-Density
2
Cleared 510(K)
K
17
3636
Velocity
2
Cleared 510(K)
K
17
0793
SuRgical Planner (SRP)
2
Cleared 510(K)
K
18
0091
UNiD Spine Analyzer
2
Cleared 510(K)
K
16
2727
SENYINT Remote Consultation System
2
Cleared 510(K)
K
17
2832
Insight BD
2
Cleared 510(K)
K
17
2490
eUnity
2
Cleared 510(K)
K
17
3512
MFI-Cardiac
2
Cleared 510(K)
K
17
3088
Vitrea Software Toshiba Package VSTP-001A
2
Cleared 510(K)
K
17
3542
Arterys Oncology DL
2
Cleared 510(K)
K
17
3622
CS Imaging
2
Cleared 510(K)
K
17
3054
Navigo Workstation Version 2.0
2
Cleared 510(K)
K
17
3588
Illumeo System
2
Cleared 510(K)
K
17
2224
DTX Studio diagnose
2
Cleared 510(K)
K
17
1328
cNeuro cMRI
2
Cleared 510(K)
K
17
3456
ViewPoint 6
2
Cleared 510(K)
K
17
3420
Radiomics App v1.0
2
Cleared 510(K)
K
17
3467
Advanced Diffusion Analysis (ADA) application
2
Cleared 510(K)
K
17
3475
Merge PACS
2
Cleared 510(K)
K
17
2218
MIM – Y90 Dosimetry
2
Cleared 510(K)
K
17
3378
syngo®.via protoNeo (Version VA20)
2
Cleared 510(K)
K
17
3329
jFit Surgical Planner
2
Cleared 510(K)
K
17
1385
Planmeca Romexis
2
Cleared 510(K)
K
17
3247
Surgical Planning Software version 1.1
2
Cleared 510(K)
K
17
2803
Infinitt PACS 7.0
2
Cleared 510(K)
K
17
3094
OrthoVision
2
Cleared 510(K)
K
17
1709
BR-FHUS Viewer 1.0
2
Cleared 510(K)
K
16
3623
Quantra
2
Cleared 510(K)
K
17
3101
Curve Image 2.0 PACS
2
Cleared 510(K)
K
17
1068
OrthoView 7.2
2
Cleared 510(K)
K
17
2855
Vitrea Advanced Visualization, Version 7.6
2
Cleared 510(K)
K
17
1463
ASPIRE Bellus II
2
Cleared 510(K)
K
17
0816
Elements Image Fusion, Elements Cranial Distortion Correction, Elements Spine Curvature Correction, Elements TRAM
2
Cleared 510(K)
K
17
2513
3D Echo
2
Cleared 510(K)
K
17
0981
NeuroQuant
2
Cleared 510(K)
K
17
2327
VMA™ System version 3.0
2
Cleared 510(K)
K
17
2364
EzDent-i / E2 / Prora View
2
Cleared 510(K)
K
17
1617
OKI Surgical Planning Software
2
Cleared 510(K)
K
17
1356
Clarity Reveal
2
Cleared 510(K)
K
17
1754
NovaPACS
2
Cleared 510(K)
K
16
3048
Smart Stitching Software System, Image Processing, Radiological
2
Cleared 510(K)
K
17
0841
BiopSee, Mobile US
2
Cleared 510(K)
K
16
3232
Vitrea View
2
Cleared 510(K)
K
17
1544
Arterys Viewer
2
Cleared 510(K)
K
17
0729
Examion X-AQS
2
Cleared 510(K)
K
17
1115
3D Endo Software
2
Cleared 510(K)
K
17
0434
Enterprise Imaging XERO Viewer 8.1
2
Cleared 510(K)
K
16
3668
SUITESTENSA
2
Cleared 510(K)
K
17
0847
EchoPAC Software Only, EchoPAC Plug-in
2
Cleared 510(K)
K
17
0747
syngo Application Software
2
Cleared 510(K)
K
17
1222
Vitrea Software Toshiba Package; VSTP-001A
2
Cleared 510(K)
K
17
0250
SmartTarget
2
Cleared 510(K)
K
17
1053
syngo Dynamics Version VA30
2
Cleared 510(K)
K
17
1314
QLAB Advanced Quantification Software
2
Cleared 510(K)
K
16
2574
AmCAD-US
2
Cleared 510(K)
K
17
0172
UNiD Spine Analyzer
2
Cleared 510(K)
K
16
3071
vascuCAP
2
Cleared 510(K)
K
17
0195
QuantX
2
Cleared 510(K)
K
16
1601
Dynamika
2
Cleared 510(K)
K
17
0419
SurgiCase Viewer
2
Cleared 510(K)
K
16
3622
Lung Vision
2
Cleared 510(K)
K
16
3250
Longitudinal Brain Imaging (LoBI) application
2
Cleared 510(K)
K
17
0180
Will3D
2
Cleared 510(K)
K
17
1130
Nucleus Image Management System
2
Cleared 510(K)
K
16
3119
NaviSuite SSI Edition
2
Cleared 510(K)
K
16
2647
NuVasive NuvaLine Mobile App
2
Cleared 510(K)
K
17
0952
syngo.CT View&GO
2
Cleared 510(K)
K
17
0069
AmCAD-UV
2
Cleared 510(K)
K
16
2799
Cliniview
2
Cleared 510(K)
K
17
0580
Carestream Vue PACS
2
Cleared 510(K)
K
16
2287
Synapse 3D Perfusion Analysis
2
Cleared 510(K)
K
16
3076
Segment CMR
2
Cleared 510(K)
K
16
1341
LIFESYS PACS
2
Cleared 510(K)
K
16
2559
Move Forward 3D Motion Simulation Service
2
Cleared 510(K)
K
16
3290
INFINITT ULite
2
Cleared 510(K)
K
16
3405
360KS Implant Positioning System
2
Cleared 510(K)
K
16
2868
Exam Vue PACS
2
Cleared 510(K)
K
17
0451
FDX Console (DR-ID300CL) Software
2
Cleared 510(K)
K
17
0167
True 3D Viewer Software
2
Cleared 510(K)
K
16
2484
Lung Nodule Assessment and Comparison Option (LNA)
2
Cleared 510(K)
K
16
3285
syngo Application Software
2
Cleared 510(K)
K
16
2830
SIS Software
2
Cleared 510(K)
K
16
3294
syngo.MR General, syngo.MR Cardiology, syngo.MR Neurology
2
Cleared 510(K)
K
16
0934
UC-CARE NaviGo Workstation
2
Cleared 510(K)
K
16
3122
NobelClinician, DTX Studio implant
2
Cleared 510(K)
K
16
3324
nordicBrainEx
2
Cleared 510(K)
K
16
2285
EBM iDO Viewer 1.2.1
2
Cleared 510(K)
K
16
3574
Multi Modality Viewer
2
Cleared 510(K)
K
16
3533
EzDent-i; E2; ProraView
2
Cleared 510(K)
K
16
1841
D2P
2
Cleared 510(K)
K
16
3013
Quantib Brain 1.2
2
Cleared 510(K)
K
16
3253
Arterys Cardio DL
2
Cleared 510(K)
K
16
1270
CephSimulation
2
Cleared 510(K)
K
16
3421
syngo.via MI Workflows
2
Cleared 510(K)
K
16
1959
ClearView cCAD
2
Cleared 510(K)
K
16
3539
Ez3D-i / E3
2
Cleared 510(K)
K
16
2955
Multi-Modality Tumor Tracking (MMTT) application
2
Cleared 510(K)
K
16
0852
Zia
2
Cleared 510(K)
K
16
2376
CAAS MR 4D Flow
2
Cleared 510(K)
K
16
1322
CT CoPilot
2
Cleared 510(K)
K
15
2009
DENSEEMAMMO v1.0
2
Cleared 510(K)
K
16
3158
MEDSYNAPSE Zero Footprint Viewer
2
Cleared 510(K)
K
16
2743
ViewPoint 6
2
Cleared 510(K)
K
16
2541
syngo Application Software
2
Cleared 510(K)
K
16
1515
eUnity
2
Cleared 510(K)
K
16
1634
IPS CaseDesigner
2
Cleared 510(K)
K
16
2513
Arterys Software v2.0
2
Cleared 510(K)
K
16
2145
vRad PACS with Mammography
2
Cleared 510(K)
K
16
2474
Artemis
2
Cleared 510(K)
K
16
2025
IntelliSpace Portal Platform
2
Cleared 510(K)
K
16
2011
MedDream
2
Cleared 510(K)
K
16
0371
NovaPACS
2
Cleared 510(K)
K
16
1109
iSR'obot MRI-US Fusion
2
Cleared 510(K)
K
16
0666
Dentiq3D
2
Cleared 510(K)
K
16
1828
kneeEOS
2
Cleared 510(K)
K
16
2339
Scenium
2
Cleared 510(K)
K
16
2112
CAAS MRV
2
Cleared 510(K)
K
16
1625
PixelShine
2
Cleared 510(K)
K
16
2008
JiveX
2
Cleared 510(K)
K
16
2141
Restore PACS
2
Cleared 510(K)
K
15
3705
PROcedure Rehearsal Studio
2
Cleared 510(K)
K
16
1130
ResolutionMD
2
Cleared 510(K)
K
16
1518
PACS CORE/ENCORE
2
Cleared 510(K)
K
15
2949
WebPAX
2
Cleared 510(K)
K
16
1955
5D Viewer
2
Cleared 510(K)
K
16
1148
icobrain
2
Cleared 510(K)
K
16
1113
QXLink
2
Cleared 510(K)
K
16
0284
JointPoint
2
Cleared 510(K)
K
16
0937
Senolris
2
Cleared 510(K)
K
16
1382
LVivo Software Application
2
Cleared 510(K)
K
16
1118
SIMPLANT Online Case Review and SIMPLANT Editor
2
Cleared 510(K)
K
16
1419
Multi Modality Viewer
2
Cleared 510(K)
K
16
1685
syngo®.via protoNeo (Version VA10A)
2
Cleared 510(K)
K
16
1479
hipEOS
2
Cleared 510(K)
K
16
0584
Surgical Navigation Advanced Platform (SNAP)
2
Cleared 510(K)
K
16
1559
Kuvia3D
2
Cleared 510(K)
K
16
1061
IMPAX Volume Viewing 4.0
2
Cleared 510(K)
K
16
1444
DBSWIN and VistaEasy Imaging Software
2
Cleared 510(K)
K
16
0334
Advanced Medical Imaging Software Suite (KSWVWR)
2
Cleared 510(K)
K
15
3351
Quantib Brain 1
2
Cleared 510(K)
K
16
1188
HEPATIQ 1.1
2
Cleared 510(K)
K
16
1246
Ez3D-i / E3
2
Cleared 510(K)
K
15
3736
3mensio Workstation
2
Cleared 510(K)
K
16
1117
EzDent-i / E2 / Prora View
2
Cleared 510(K)
K
15
1913
MIM-Thin Client (mobile)
2
Cleared 510(K)
K
16
0914
sterEOS Workstation
2
Cleared 510(K)
K
15
3653
DICOM Viewer
2
Cleared 510(K)
K
16
0376
EndoSize
2
Cleared 510(K)
K
16
0579
Xmaru View V1 and Xmaru PACS, Medical Image Processing Software
2
Cleared 510(K)
K
16
0407
spineEOS
2
Cleared 510(K)
K
15
3284
Synaptive ImageDrive Pro
2
Cleared 510(K)
K
15
2716
EV Insite System
2
Cleared 510(K)
K
16
0150
Vitrea CT Colon Analysis
2
Cleared 510(K)
K
15
3355
Xeleris 4.0 Processing and Review Workstation
2
Cleared 510(K)
K
15
3612
ArthrexVIP Web Portal
2
Cleared 510(K)
K
16
0426
syngo.via MI Workflows
2
Cleared 510(K)
K
15
3346
syngo Application Software VD11
2
Cleared 510(K)
K
15
2602
Olea Sphere V3.0
2
Cleared 510(K)
K
16
0317
syngo.via MI Workflows
2
Cleared 510(K)
K
15
3091
IMPLANT 3D
2
Cleared 510(K)
K
15
1737
MedicVOD System
2
Cleared 510(K)
K
15
2034
FS-PACS
2
Cleared 510(K)
K
16
0315
I4 (Integrated Intelligent Imaging Informatics) system
2
Cleared 510(K)
K
14
3290
DBSWIN and VistaEasy Imaging Software
2
Cleared 510(K)
K
15
3593
CliniscanSM MRI
2
Cleared 510(K)
K
16
0001
TraumaCad Mobile Release 2.0
2
Cleared 510(K)
K
15
3103
CARESTREAM Vue PACS
2
Cleared 510(K)
K
16
0108
Synapse PACS
2
Cleared 510(K)
K
15
3166
Fusion Bx
2
Cleared 510(K)
K
15
2977
DG PACS
2
Cleared 510(K)
K
15
2352
Stereo 3D option for Vision Applications
2
Cleared 510(K)
K
15
3289
HEALTHMYNE
2
Cleared 510(K)
K
15
1075
BR-ABVS Viewer 1.0
2
Cleared 510(K)
K
15
1152
ImplantMax Software
2
Cleared 510(K)
K
15
3427
Volpara Imaging Software
2
Cleared 510(K)
K
15
2746
Ez3D Plus
2
Cleared 510(K)
K
15
2172
Econsole1
2
Cleared 510(K)
K
15
2078
Implant Studio 2015
2
Cleared 510(K)
K
15
2822
VidiStar HeartView
2
Cleared 510(K)
K
15
3022
Philips IntelliSpace Cardiovascular
2
Cleared 510(K)
K
15
3073
UroNav (Version 2.0)
2
Cleared 510(K)
K
15
2661
HICAT Air
2
Cleared 510(K)
K
15
1212
Ziostation2
2
Cleared 510(K)
K
15
2028
Volpara Imaging Software
2
Cleared 510(K)
K
15
1988
Visible Patient Suite
2
Cleared 510(K)
K
15
1941
DEXIS Webview
2
Cleared 510(K)
K
15
1501
OrthoVis Web Portal
2
Cleared 510(K)
K
15
1774
CARESTREAM Vue Motion
2
Cleared 510(K)
K
14
3586
FACT Medical Imaging Sysytem
2
Cleared 510(K)
K
15
1957
BOX DICOM Viewer
2
Cleared 510(K)
K
15
2186
HealthMyne PACS
2
Cleared 510(K)
K
15
1837
CS 3D Imaging
2
Cleared 510(K)
K
15
1371
Corporate Dental Imaging (CDI) Application
2
Cleared 510(K)
K
15
1859
Synapse Cardiovascular
2
Cleared 510(K)
K
15
1850
McKesson Cardiology
2
Cleared 510(K)
K
15
1353
syngo.MR Neurology, syngo.MR Oncology
2
Cleared 510(K)
K
15
1687
QuantorView
2
Cleared 510(K)
K
15
1568
Arthrex OrthoVis Preoperative Plan
2
Cleared 510(K)
K
15
1808
3D/5D Viewer
2
Cleared 510(K)
K
14
3368
GenIQ
2
Cleared 510(K)
K
15
1854
3MP (X213C3P0E, X213G3P0E) and 2MP (X213C2P0E, X213G2P0E) LCD Display
2
Cleared 510(K)
K
14
3176
UltraLinq
2
Cleared 510(K)
K
15
1091
Vitrea Software Toshiba Package, VSTP-001A
2
Cleared 510(K)
K
15
0313
Ablation Confirmation
2
Cleared 510(K)
K
15
1438
Dentrix Ascend Imaging
2
Cleared 510(K)
K
14
2750
JiveX
2
Cleared 510(K)
K
15
1192
syngo.via MI Workflows
2
Cleared 510(K)
K
15
0415
NilRead
2
Cleared 510(K)
K
15
0761
Ez3D-i/E3
2
Cleared 510(K)
K
15
0976
Collage
2
Cleared 510(K)
K
15
1115
MR Core Software
2
Cleared 510(K)
K
14
3397
ICIS View
2
Cleared 510(K)
K
15
0707
IntelePACS
2
Cleared 510(K)
K
15
0420
Centricity Universal Viewer
2
Cleared 510(K)
K
15
0069
Fine Structure Analysis(fineSA)
2
Cleared 510(K)
K
14
2648
SPINEDESIGN Spine Surgery Planning (Software Application)
2
Cleared 510(K)
K
14
2196
Visage Ease Pro
2
Cleared 510(K)
K
15
0843
syngo®.via (version VB10A)
2
Cleared 510(K)
K
14
2779
SCANIP; SCANIP: MEDICAL EDITION; SCANIP: MED
2
Cleared 510(K)
K
14
2647
mint Lesion
2
Cleared 510(K)
K
15
0738
VitreaView
2
Cleared 510(K)
K
15
0747
EzDent-i /E2/Prora View
2
Cleared 510(K)
K
15
0192
Scenium
2
Cleared 510(K)
K
14
3361
Mammo Workstation
2
Cleared 510(K)
K
15
0193
Customer Remote Console (CRC)
2
Cleared 510(K)
K
14
2337
Blackford Analysis Registration Product Family
2
Cleared 510(K)
K
14
3318
DR Systems Zero Download 3D Viewer (Z3D)
2
Cleared 510(K)
K
14
1536
VIEWING CLIENT MOBILE
2
Cleared 510(K)
K
15
0258
Vitrea, Version 7.0 Medical Image Processing Software
2
Cleared 510(K)
K
14
2923
TraumaCad Mobile Release 1.0
2
Cleared 510(K)
K
15
0085
GE EchoPAC
2
Cleared 510(K)
K
14
3319
Syngo X-workplace SW VD10
2
Cleared 510(K)
K
15
0122
TOMTEC-ARENA TTA2
2
Cleared 510(K)
K
14
3044
CAAS A-Valve
2
Cleared 510(K)
K
14
0828
NEUROREADER MEDICAL IMAGE PROCESSING SOFTWARE
2
Cleared 510(K)
K
14
2107
ECHO TRUE 3D VIEWER
2
Cleared 510(K)
K
14
1561
VM PACS WITH VM MEDICAL WORKSTATION
2
Cleared 510(K)
K
14
2850
McKesson Radiology Mammography Plus
2
Cleared 510(K)
K
14
2316
IMPAX Agility
2
Cleared 510(K)
K
14
0587
MR-CT VVA
2
Cleared 510(K)
K
14
2514
UniWeb 8.0
2
Cleared 510(K)
K
14
2891
HEPATIQ
2
Cleared 510(K)
K
14
2944
ArthroPlan Digital Templating Software
2
Cleared 510(K)
K
14
2919
EXA
2
Cleared 510(K)
K
14
0860
ImmersiveTouch3 and MicrovisTouch
2
Cleared 510(K)
K
14
0797
IPACS MEDICAL IMAGE MANAGEMENT SYSTEM
2
Cleared 510(K)
K
14
3254
eSie Apps Suite
2
Cleared 510(K)
K
14
2671
ONEFIT HIP PLANNER
2
Cleared 510(K)
K
14
3079
Endovascular Stent Planning Software
2
Cleared 510(K)
K
14
2521
Synapse 3D Liver and Kidney Analysis
2
Cleared 510(K)
K
14
1881
RAPIDRESULTS
2
Cleared 510(K)
K
14
1745
IQQA-BODYIMAGING SOFTWARE
2
Cleared 510(K)
K
14
1570
IMPLANT STUDIO
2
Cleared 510(K)
K
13
2853
NOVAPACS
2
Cleared 510(K)
K
14
2037
QUANTRA
2
Cleared 510(K)
K
14
1669
SURGIMAP
2
Cleared 510(K)
K
14
1607
DENTAL IMAGING SOFTWARE
2
Cleared 510(K)
K
14
0399
EBM IDO VIEWER
2
Cleared 510(K)
K
14
2048
EMPRINT PROCEDURE PLANNING APPLICATION
2
Cleared 510(K)
K
14
1137
STEREOS WORKSTATION
2
Cleared 510(K)
K
14
1514
SYNAPSE 3D TENSOR ANALYSIS
2
Cleared 510(K)
K
14
1364
CLIMB MAMMOGRAPHY VIEWER SOFTWARE
2
Cleared 510(K)
K
14
1451
VixWin Platinum
2
Cleared 510(K)
K
14
1480
CVI42
2
Cleared 510(K)
K
13
1348
ORTOMED
2
Cleared 510(K)
K
14
1302
VITREA CT MULTI-CHAMBER CARDIAC FUNCTIONAL ANALYSIS (CFA)
2
Cleared 510(K)
K
14
1061
REMOTEYE VIEWER
2
Cleared 510(K)
K
14
1475
ENDOSIZE
2
Cleared 510(K)
K
14
0897
SYNGO.MR NEUROLOGY, SYNGO.MMR GENERAL
2
Cleared 510(K)
K
14
1554
ESIE APPS SUITE
2
Cleared 510(K)
K
14
0869
DCAS I
2
Cleared 510(K)
K
14
1556
AVREO INTERWORKS SYSTEM
2
Cleared 510(K)
K
14
0909
MCKESSON RADIOLOGY
2
Cleared 510(K)
K
14
0819
SURGICAL NAVIGATION ADVANCED PLATFORM
2
Cleared 510(K)
K
14
1329
RADSPA
2
Cleared 510(K)
K
14
1199
QUENTRY DOSE REVIEW
2
Cleared 510(K)
K
14
0713
PLANMECA ROMEXIS
2
Cleared 510(K)
K
14
0960
PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
2
Cleared 510(K)
K
13
3098
SENYINT PACS
2
Cleared 510(K)
K
14
0434
MEDICAD CLASSIC
2
Cleared 510(K)
K
14
0337
BRIGHTMATTER PLANNING SOFTWARE
2
Cleared 510(K)
K
14
0139
CLEARVIEWHD
2
Cleared 510(K)
K
13
2684
MEDWS SOFTWARE (VARIANTS MEDVIEW, MEDDIAG, MEDMAMMO)
2
Cleared 510(K)
K
14
0395
VITREA IMAGE DENOISING SOFTWARE
2
Cleared 510(K)
K
14
0445
DEXIS SOFTWARE: DEXIS IMAGING SUITE, DEXIS MAC
2
Cleared 510(K)
K
14
0808
Q-STATION
2
Cleared 510(K)
K
13
3521
AZE PHOENIX SOFTWARE
2
Cleared 510(K)
K
13
3910
NORDICBRAINEX
2
Cleared 510(K)
K
14
0271
TABLET VIEWER SOFTWARE FOR IMAGE SUITE
2
Cleared 510(K)
K
13
3984
CORONIS 5MP
2
Cleared 510(K)
K
13
3508
RESOLUTIONMD MOBILE
2
Cleared 510(K)
K
13
3663
NIO COLOR 2MP
2
Cleared 510(K)
K
13
3401
SYNO MR NEUROLOGY, SYNGO MR ONCOLOGY, SYNGO. MR BREVIS, SYNGO MMR GENERAL
2
Cleared 510(K)
K
14
0093
TABLE
2
Cleared 510(K)
K
13
3135
IMPAX VOLUME VIEWING 3.0
2
Cleared 510(K)
K
13
3966
MODEL-BASED RSA SOFTWARE
2
Cleared 510(K)
K
13
3022
ZEDVIEW
2
Cleared 510(K)
K
13
3937
HEARTSCAN SOFTWARE
2
Cleared 510(K)
K
13
3654
SCENIUM
2
Cleared 510(K)
K
13
3609
THE DOME S6C
2
Cleared 510(K)
K
13
2763
ADVANCED VIEWER
2
Cleared 510(K)
K
14
0033
TARGET3D FUSION
2
Cleared 510(K)
K
13
3385
LUNGPOINT ATV PLANNING AND NAVIGATION SOFTWARE
2
Cleared 510(K)
K
13
3644
SYNGO.VIA MI WORKFLOWS
2
Cleared 510(K)
K
13
3320
SICAT FUNCTION
2
Cleared 510(K)
K
14
0214
30.0 INCH COLOR LCD MONITOR CCL650I2 (CL30650, MD302C6)
2
Cleared 510(K)
K
14
0103
3MP GRAYSCAKE LCD DISPLAY
2
Cleared 510(K)
K
14
0108
3MP COLOR LCD DISPLAY
2
Cleared 510(K)
K
13
3708
MD302C4 29.8 DIAGNOSTIC IMAGING LCD MONITOR
2
Cleared 510(K)
K
13
2824
CARESTREAM VUE PACS VERSION 11.4 CARESTREAM VUE MOTION APPLICATION
2
Cleared 510(K)
K
13
4002
6MP COLOR LCD MONITOR, RADIFORCE RX650
2
Cleared 510(K)
K
13
3730
CO PILOT/REGIUS UNITEA
2
Cleared 510(K)
K
13
2770
DOME S10
2
Cleared 510(K)
K
13
3030
DYNACAD/PROSTATE INTERVENTIONAL (DYNALOC/PROSTATE)
2
Cleared 510(K)
K
13
2499
ICRCO CLARITY VIEWER
2
Cleared 510(K)
K
13
3875
THE KINEGRAPH VMA (VERTEBRAL MOTION ANALYZER) SOFTWARE VERSION 2.2, THE MOTION NORMALIZER PATIENT HANDLING AND DATA
2
Cleared 510(K)
K
13
3686
21.3 INCH (54 CM) INCH MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS35i2 (ML21035)
2
Cleared 510(K)
K
13
0998
SYNGO.VIA WEB VIEWER
2
Cleared 510(K)
K
13
2095
OLEA SPHERE
2
Cleared 510(K)
K
13
1447
INTUITION - TDA, TVA, PARAMETRIC MAPPING
2
Cleared 510(K)
K
13
3367
ORTHOVIS PREOPERATIVE PLAN
2
Cleared 510(K)
K
13
2342
XVWEB
2
Cleared 510(K)
K
13
3511
21.3 INCH(54 CM) MONOCHROME LCD MONITOR MS25I2(ML21025)
2
Cleared 510(K)
K
13
2963
FUSIONSYNC, CHIMAERA FUSIONSYNC
2
Cleared 510(K)
K
13
2773
SIDEXIS 4
2
Cleared 510(K)
K
13
2532
SYNGO.PLAZA VB10A
2
Cleared 510(K)
K
13
3181
21.3 INCH (54 CM) COLOR LCD MONITOR CCL258I2 (CL21258)
2
Cleared 510(K)
K
13
3185
21.3 INCH (54 CM) COLOR LCD MONITOR CCL358I2 (CL21358)
2
Cleared 510(K)
K
13
2742
M-VU BREAST DENSITY
2
Cleared 510(K)
K
13
1390
JUSHA-M52C MEDICAL DISPLAY
2
Cleared 510(K)
K
13
3357
CHARRUAPACS SYSTEM
2
Cleared 510(K)
K
13
2544
TOMTEC-ARENA 1.0, TOMTEC-ARENA 3D ECHO, CARDIO-ARENA
2
Cleared 510(K)
K
13
2799
CLARISO PACS
2
Cleared 510(K)
K
13
2586
PAXERAPACS
2
Cleared 510(K)
K
13
2316
MULTIVIEW
2
Cleared 510(K)
K
13
2188
MAMMOGRAPHY VIEWER SMV658
2
Cleared 510(K)
K
13
2636
DYONICS PLAN HIP IMPINGEMENT PLANNING SYSTEM
2
Cleared 510(K)
K
12
1447
ISCHEMA VIEW RAPID
2
Cleared 510(K)
K
12
2536
AMCAD-UT DETECTION MODEL 2.0
2
Cleared 510(K)
K
13
1873
NDOHD HIGH DEFINITION IMAGING SYSTEM (NDOHD)
2
Cleared 510(K)
K
13
1685
GE ECHOPAC
2
Cleared 510(K)
K
13
1977
CENTRICITY UNIVERSAL VIEWER ZERO FOOTPRINT CLIENT
2
Cleared 510(K)
K
13
2302
QXLINK
2
Cleared 510(K)
K
13
1389
JUSHA-C31 MEDICAL DISPLAY
2
Cleared 510(K)
K
12
3944
KOSTEC MEDICAL GRADE LDC MONITORS
2
Cleared 510(K)
K
13
2610
5MP GRAYSCALE LCD DISPLAY
2
Cleared 510(K)
K
13
2587
MD242C2 24 DIAGNOSTIC IMAGING LCD MONITOR
2
Cleared 510(K)
K
13
1594
EZDENTI-I; E2; PRORA VIEW
2
Cleared 510(K)
K
13
1616
EZ3D-I, E3
2
Cleared 510(K)
K
13
0374
OMNI-VUE 2 SYSTEM
2
Cleared 510(K)
K
13
0242
MAVEN PRO
2
Cleared 510(K)
K
13
1391
JUSHA-M32 MEDICAL DISPLAY
2
Cleared 510(K)
K
13
1158
CORVIEW
2
Cleared 510(K)
K
13
0749
SYNGO.MR GENERAL; SYNGO.MR CARDIOLOGY; SYNGO.MR VASCULAR
2
Cleared 510(K)
K
13
1570
ORTHOVISION
2
Cleared 510(K)
K
13
0779
LVIVO EF SYSTEM
2
Cleared 510(K)
K
13
2165
QLAB QUANTIFICATION SOFTWARE
2
Cleared 510(K)
K
13
0743
THE KINEGRAPH VMA (VERTEBRAL MOTION ANALYZER) SOFTWARE VERSION 2.0; THE MOTION NORMALIZER PATIENT HANDLING AND DATA COLL
2
Cleared 510(K)
K
13
1448
3D PROSTATE SUITE 3DTRUS PROSTATE MAPPING, MRI/3DTRUS FUSION OPTION, SECOND LOOK 3DTRUS FUSION OPTION
2
Cleared 510(K)
K
13
1498
IQQA-LIVER MULTIMODALITY SOFTWARE
2
Cleared 510(K)
K
13
2062
ESIE APPS SUITE
2
Cleared 510(K)
K
13
1822
ULTRAEXTEND USWS-900A V2.1 AND V3.1
2
Cleared 510(K)
K
13
1137
21.3 INCH MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS55I2 (ML21055, MD211G5)
2
Cleared 510(K)
K
13
1424
MIPLATFORM MEDICAL IMAGING SUITE
2
Cleared 510(K)
K
13
1090
2MP COLOR LCD MONITOR, RADIFORCE MX215
2
Cleared 510(K)
K
13
0724
CODIAGNOSTIX IMPLANT PLANNING SOFTWARE
2
Cleared 510(K)
K
13
0542
SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS
2
Cleared 510(K)
K
13
1392
ETIAM PACS COMPONENTS
2
Cleared 510(K)
K
13
1295
NIO COLOR 3MP LED
2
Cleared 510(K)
K
13
0278
MR PERMEABILITY
2
Cleared 510(K)
K
13
1246
CORONIS 3MP
2
Cleared 510(K)
K
13
1299
ANYTHINK PACS WORKSTATION
2
Cleared 510(K)
K
12
3306
NORDIC TUMOREX
2
Cleared 510(K)
K
12
4051
THE VAULT SYSTEM
2
Cleared 510(K)
K
13
1118
4D VIEW
2
Cleared 510(K)
K
12
3082
MOBILECT VIEWER
2
Cleared 510(K)
K
13
0159
QLAB QUANTIFICATION SOFTWARE HEART MODEL
2
Cleared 510(K)
K
13
0624
CONI
2
Cleared 510(K)
K
13
0770
MD211C3 21.3 DIAGNOSTIC IMAGING LCD MONITOR
2
Cleared 510(K)
K
13
0772
MD211C2 21.3 DIAGNOSTIC IMAGING LCD MONITOR
2
Cleared 510(K)
K
13
0929
ZMED VP4000
2
Cleared 510(K)
K
13
0884
XELERIS 3.1 PROCESSING AND REVIEW WORKSTATION
2
Cleared 510(K)
K
13
0383
SYNAPSE 3D CARDIAC TOOLS
2
Cleared 510(K)
K
13
0069
INNOVA EPVISION 2.0, INNOVA EPVISION 2.0
2
Cleared 510(K)
K
12
1916
INTUITION
2
Cleared 510(K)
K
13
0336
5MP MONOCHROME LCD MONITOR, RADIFORCE GX540
2
Cleared 510(K)
K
12
3976
NOBELCLINICIAN
2
Cleared 510(K)
K
13
0393
MIRADA RTX
2
Cleared 510(K)
K
13
0228
SUITEHEART
2
Cleared 510(K)
K
12
3186
RESOLUTIONMD MOBILE 3.1 MODEL RMD-MOB-31
2
Cleared 510(K)
K
13
0395
STEREOS WORKSTATION
2
Cleared 510(K)
K
12
3426
MEDICVOD, MEDICAST, MEDISHOW, MEDISEARCH, CENTRAL STORAGE SYSTEM - CSS
2
Cleared 510(K)
K
12
2578
VITREA CT TRANSCATHETER AORTIC VALVE REPLACMENT (TAVR) PLANNING
2
Cleared 510(K)
K
12
3650
ARIX RAD ACQUISITION CONSOLE
2
Cleared 510(K)
K
12
3575
MAMMOWORKSTATION
2
Cleared 510(K)
K
12
0851
COMMUNIFY PACS VIEWER
2
Cleared 510(K)
K
13
0103
CORONIS FUSION 6MP
2
Cleared 510(K)
K
13
0070
4MP COLOR LCD MONITOR, RADIFORCE RX440
2
Cleared 510(K)
K
12
3023
SURGERY REHEARSAL PLATFORM
2
Cleared 510(K)
K
12
3970
CAAS INTRAVASCULAR
2
Cleared 510(K)
K
12
3519
INVIVO DENTAL
2
Cleared 510(K)
K
12
3420
SYNGO, BREAST CARE
2
Cleared 510(K)
K
12
4048
IMAGEQUBE
2
Cleared 510(K)
K
12
3901
TRACTUS TISSUEMAPPER REVIEWER APPLICATION
2
Cleared 510(K)
K
12
3894
GE ECHOPAC
2
Cleared 510(K)
K
12
3269
PROCEDURE REHEARSAL STUDIO
2
Cleared 510(K)
K
12
3566
SYNAPSE 3D COLON ANALYSIS
2
Cleared 510(K)
K
12
3577
SYNGO.VIA MI WORKFLOWS
2
Cleared 510(K)
K
12
3920
SYNGO.VIA
2
Cleared 510(K)
K
12
1762
CARDIAC VX
2
Cleared 510(K)
K
12
3922
SYNGO DYNAMICS
2
Cleared 510(K)
K
12
3302
IB CLINIC
2
Cleared 510(K)
K
12
1296
INTERVENTIONAL WORKSPOT
2
Cleared 510(K)
K
12
3526
CLEARREAD +CONFIRM
2
Cleared 510(K)
K
12
3528
SCENIUM
2
Cleared 510(K)
K
12
3530
MAMMOGRAPHY PRIOR ENHANCEMENT (MPE)
2
Cleared 510(K)
K
12
0995
ERAD PACS/ERAD RIS/PACS/ERAD EPVLITE VIEWER SOFTWARE PRODUCT
2
Cleared 510(K)
K
12
2429
VESSEL ANALYSIS AND AUTOPLAQUE FOR ORS VISUAL
2
Cleared 510(K)
K
12
3375
SYNGO.VIA
2
Cleared 510(K)
K
12
3174
CENTRICITY PACS-IW WITH UNIVERSAL VIEWER
2
Cleared 510(K)
K
11
3344
STEREOS WORKSTATION
2
Cleared 510(K)
K
12
1213
VITREAADVANCED
2
Cleared 510(K)
K
12
1200
FLIGHTPLAN FOR LIVER
2
Cleared 510(K)
K
12
1781
ECHONAVIGATOR RELEASE 1
2
Cleared 510(K)
K
12
2289
IMAGE-COM 5.0
2
Cleared 510(K)
K
12
2523
CARESTREAM VUE PACS
2
Cleared 510(K)
K
12
1076
ULTRAEXTEND FX, ULTRASOUND WORKSTATION PACKAGE
2
Cleared 510(K)
K
12
2843
MD211G3 21.3 DIAGNOSTIC IMAGING LCD MONITOR
2
Cleared 510(K)
K
12
2022
ATHEROEDGE
2
Cleared 510(K)
K
11
1142
ECHOSOFT(TM)
2
Cleared 510(K)
K
12
0288
ORTHOCAD SOFTWARE OPTION
2
Cleared 510(K)
K
12
2427
CS ORTHODONTIC IMAGING SOFTWARE CS OMS IMAGING SOFTWARE
2
Cleared 510(K)
K
12
2260
AYCAN MOBILE
2
Cleared 510(K)
K
12
2164
MR VESSELLQ XPRESS
2
Cleared 510(K)
K
12
2136
VITREAVIEW
2
Cleared 510(K)
K
12
2329
BIOJET
2
Cleared 510(K)
K
12
2205
EXINI
2
Cleared 510(K)
K
12
0451
8MP COLOR LCD MONITOR, REDIFORCE RX840
2
Cleared 510(K)
K
12
0734
MICROSOFT AMALGA UIS IMAGE PROCESSING MODULE
2
Cleared 510(K)
K
12
1292
DYNAPBV BODY SOFTWARE
2
Cleared 510(K)
K
12
1075
NERVEVISION SOFTWARE SYSTEMS
2
Cleared 510(K)
K
12
1788
NIO 5MP
2
Cleared 510(K)
K
12
1517
VERSAVUE ENTERPRISE SUITE
2
Cleared 510(K)
K
11
3562
3MP COLOR LCD MONITOR, RADIFORCE RX340
2
Cleared 510(K)
K
11
3620
MYRIAN 1.11
2
Cleared 510(K)
K
12
1449
DIRECTPATH
2
Cleared 510(K)
K
12
0305
THINKINGNET, THINKINGPACS/RIS - PROPRIETARY NAME FRO THINKINGNET, THINKINGARCHIVE (OR NUPAX) - THE MANAGEMENT AND ARCHIV
2
Cleared 510(K)
K
12
0733
SIMPLANT GO
2
Cleared 510(K)
K
12
0636
SYNAPSE 3D CARDIAC TOOLS
2
Cleared 510(K)
K
12
0514
CARDIOPACS
2
Cleared 510(K)
K
12
1459
SYNGO.MR NEUROLOGY
2
Cleared 510(K)
K
12
0472
QUANTRA
2
Cleared 510(K)
K
11
3456
READY VIEW
2
Cleared 510(K)
K
12
0648
SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS
2
Cleared 510(K)
K
12
1074
SCENIUM 2.0
2
Cleared 510(K)
K
12
1387
CENTRICITY PACS-IW
2
Cleared 510(K)
K
12
0679
SYNAPSE 3D NODULE ANALYSIS
2
Cleared 510(K)
K
12
1466
GUIDEMIA
2
Cleared 510(K)
K
12
1023
SPECTRUM V.0
2
Cleared 510(K)
K
11
3739
SIMPLANT IMMEDIATE SMILE DENTAL CARE SYSTEM
2
Cleared 510(K)
K
12
1223
QLAB WITH FHN AND VPQ PLUG-IN
2
Cleared 510(K)
K
12
0637
SYNAPSE 3D BRAIN PERFUSION
2
Cleared 510(K)
K
11
3599
SURGICASE CONNECT
2
Cleared 510(K)
K
12
0207
VISIA
2
Cleared 510(K)
K
11
3240
3.7 MP COLOR LCD MONITOR, RADIFORCE MX270W
2
Cleared 510(K)
K
12
0718
INSTAPACS/INSTARISPACS
2
Cleared 510(K)
K
12
0407
2MP MONOCHROME LCD MONITOR, RADIFORCE GX240
2
Cleared 510(K)
K
12
0196
OLEA SPHERE
2
Cleared 510(K)
K
12
0076
RESOLUTIONMD WEB
2
Cleared 510(K)
K
12
0367
3MENSIO WORKSTATION
2
Cleared 510(K)
K
12
0315
SYNGO.MR SPECTRO ENGINE, SYNGO.MR SPECTRO SVS, SYNGO.MR SPECTRO CSI, SYNGO.MR SPECTRO EXTENSION
2
Cleared 510(K)
K
12
0161
ALPHAPOINT IMAGING SOFTWARE
2
Cleared 510(K)
K
12
0135
2D CARDIAC PERFORMANCE ANALYSIS MR 1.0
2
Cleared 510(K)
K
12
0709
THE DOME GX4MP COLOR NONITOR
2
Cleared 510(K)
K
12
0361
SYNAPSE 3D BASE TOOLS
2
Cleared 510(K)
K
12
0187
MULTI-MODALITY IMAGE FUSION
2
Cleared 510(K)
K
12
0221
GE ECHOPAC
2
Cleared 510(K)
K
12
0484
VISIA ONCOLOGY
2
Cleared 510(K)
K
12
0115
ORTHOSIZE
2
Cleared 510(K)
K
12
0525
QLAB QUANTIFICATION SOFTWARE
2
Cleared 510(K)
K
11
3082
SONOVISION
2
Cleared 510(K)
K
11
3784
3MP MONOCHROME LCD MONITOR, RADIFORCE GX340
2
Cleared 510(K)
K
11
3844
RADIFORCE RX240
2
Cleared 510(K)
K
11
2807
X-RAY VVA
2
Cleared 510(K)
K
11
2679
SIMPLANT NAVIGATOR PERSONALIZED DENTAL CARE SYSTEM
2
Cleared 510(K)
K
11
3701
VISIA NEURO
2
Cleared 510(K)
K
11
3442
3DI
2
Cleared 510(K)
K
11
3419
CS IMAGING
2
Cleared 510(K)
K
11
1758
CADENS (TM) COLON
2
Cleared 510(K)
K
11
3076
CAAS A-VALVE
2
Cleared 510(K)
K
11
2720
MCKESSON HORIZON CARDIOLOGY
2
Cleared 510(K)
K
11
1385
DELL ULTRASHARP U3011 W/QUBYX PERFECTLUM BUNDLE
2
Cleared 510(K)
K
11
2251
SWISSMEDA DENTAL PLANNING SYSTEM
2
Cleared 510(K)
K
11
2008
TOUCHPACS SUITE
2
Cleared 510(K)
K
11
1861
SYNGO.MR ONCO, SYNGO.MR 3D LESION SEGMENTATION, SYNGO.MR ONCO ENGINE
2
Cleared 510(K)
K
11
1776
DELTAVIEW MODEL 2.1
2
Cleared 510(K)
K
11
2387
PROCEDURE REHEARSAL STUDIO(TM)
2
Cleared 510(K)
K
11
3443
21.3 INCH (54 CM) MONOCHROME LCD MONITOR MS23I2 (ML21023)
2
Cleared 510(K)
K
11
3244
SYNAPSE MPR FUSION
2
Cleared 510(K)
K
11
2109
THE KINEGRAPH VMA SOFTWARE, THE MOTION NORMALIZER PATIENT HANDLING AND DATA COLLECTION DEVICE
2
Cleared 510(K)
K
11
3136
21.3INCH (54CM)COLOR LCD MONITOR CCL256I2(CL21256)
2
Cleared 510(K)
K
10
3554
METRON-CP/MD
2
Cleared 510(K)
K
11
3226
8MP COLOR LCD MONITOR,RADIFORCE RX840
2
Cleared 510(K)
K
11
3541
CLEARSTART SVM SYSTEM
2
Cleared 510(K)
K
11
3543
ONDEMAND3D
2
Cleared 510(K)
K
11
2480
VIEW 1 IMAGING
2
Cleared 510(K)
K
11
3404
DENTAL 3D PLANNING SOFTWARE
2
Cleared 510(K)
K
11
2930
MOBILE MIM
2
Cleared 510(K)
K
11
2570
CENTRICITY CARDIO IMAGING
2
Cleared 510(K)
K
11
2354
5MP MONOCHROME LCD MONITOR, RADIFORCE GX530
2
Cleared 510(K)
K
11
3029
SYNGO VIA MI WORKFLOWS
2
Cleared 510(K)
K
11
2531
VITREA CT MYOCARDIAL ANALYSIS
2
Cleared 510(K)
K
11
1642
ONCO TRAC MODEL 1, 2, 4
2
Cleared 510(K)
K
11
0596
MW100 (MAMMOGRAPHY) LCD MONITOR SYSTEM
2
Cleared 510(K)
K
11
2145
MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS33I2
2
Cleared 510(K)
K
11
1161
PERFSCAPE V2.0
2
Cleared 510(K)
K
11
0765
FXA (TM)
2
Cleared 510(K)
K
10
0784
UC-CARE NAVIGO SYTEM
2
Cleared 510(K)
K
11
2604
21.3 INCH (54 CM) COLOR LCD MONITOR CCL356I2 (CL21356)
2
Cleared 510(K)
K
11
2466
4MP COLOR LCD MONITOR, RADIFORCERX430
2
Cleared 510(K)
K
11
2974
PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
2
Cleared 510(K)
K
11
0919
CARESTREAM PACS
2
Cleared 510(K)
K
11
2439
SYNAPSE WORKSTATION SOFTWARE VERSION 3.3.0
2
Cleared 510(K)
K
11
1990
CORONIS 5MP
2
Cleared 510(K)
K
11
2051
LUNGPOINT PLANNING AND VIRTUAL BRONCHOSCOPIC NAVIGATION (VBN) SOFTWARE
2
Cleared 510(K)
K
11
2530
3DI INCLUDING CSCORE
2
Cleared 510(K)
K
11
2096
IMAGELINK
2
Cleared 510(K)
K
11
1019
SURGIMAP (TM) SPINE
2
Cleared 510(K)
K
11
1641
SURGICASE ORTHOGNATHIC SOFTWARE WIZARD
2
Cleared 510(K)
K
11
1496
21.3 INCH (54CM) MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR
2
Cleared 510(K)
K
11
1989
CORONIS FUSION 4MP DL
2
Cleared 510(K)
K
11
1833
VIRTUE
2
Cleared 510(K)
K
11
1731
MOLECULAR BREAST IMAGING SOFTWARE
2
Cleared 510(K)
K
11
1694
ASTRA
2
Cleared 510(K)
K
11
0033
FEEL-DRCS
2
Cleared 510(K)
K
10
1898
R4 ACERT ULTRASOUND REPORTING SYSTEM
2
Cleared 510(K)
K
11
1660
XELIS CARDIAC
2
Cleared 510(K)
K
11
1346
RESOLUTIONMD MOBILE MODEL RMB-MOB-2X
2
Cleared 510(K)
K
11
1613
XELIS FUSION
2
Cleared 510(K)
K
10
3308
AIDA HD CONNECT WITH SMARTSCREEN / BLU-RAY DRIVE / SMARTSCREEN WITH BLU-RAY DRIVE
2
Cleared 510(K)
K
10
3181
ZENIS, PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
2
Cleared 510(K)
K
11
1373
CT42 CARDIAC COMPUTED TOMOGRAPHY (CT) SOFTWARE
2
Cleared 510(K)
K
11
1991
NIO COLOR 2MP
2
Cleared 510(K)
K
10
2078
RADIOLOGICAL IMAGE PROCESSING SYSTEM
2
Cleared 510(K)
K
11
1945
IMPAX NEXT GENERATION
2
Cleared 510(K)
K
11
1319
IBIS EXPLORER AND MARKUP SOFTWARE
2
Cleared 510(K)
K
11
1245
HEARTNAVIGATOR RELEASE 1
2
Cleared 510(K)
K
11
1892
VITREAVIEW SOFTWARE 6.1
2
Cleared 510(K)
K
11
1804
INTELLISPACE PACS 4.X
2
Cleared 510(K)
K
11
1222
MRI-Q SYSTEM
2
Cleared 510(K)
K
10
3130
XELIS 3D
2
Cleared 510(K)
K
11
0797
COMMUNIFY PACS VIEWER
2
Cleared 510(K)
K
11
0300
SIMPLANT 2011
2
Cleared 510(K)
K
11
0886
CLIO/CLIOSOFT
2
Cleared 510(K)
K
11
1638
IMPAX VOLUME VIEWING
2
Cleared 510(K)
K
11
0414
QLAB 8.1 QUANTIFICATION SOFTWARE
2
Cleared 510(K)
K
11
1237
MD301C4 29.8 DIAGNOSTIC IMAGING LCD MONITOR, L309TY
2
Cleared 510(K)
K
10
3724
10 MP GRAYSCALE FLAT PANEL DISPLAY (GX 1030)
2
Cleared 510(K)
K
11
0447
ECHOINSIGHT
2
Cleared 510(K)
K
11
1336
EBW NM 2.0
2
Cleared 510(K)
K
10
2534
AZE VIRTUALPLACE-MR FLOW ANALYSIS SOFTWARE
2
Cleared 510(K)
K
11
1052
SYNGO NEURO PBV-IR
2
Cleared 510(K)
K
10
3723
SICAT IMPLANT V1.2
2
Cleared 510(K)
K
11
1079
SYNGO.VIA WEB VIEWER
2
Cleared 510(K)
K
11
0430
DOLPHIN IMAGING
2
Cleared 510(K)
K
11
1164
EUNITY
2
Cleared 510(K)
K
11
1102
RADIOVISION
2
Cleared 510(K)
K
11
0875
CENTRICITY PACS
2
Cleared 510(K)
K
11
0573
READY VIEW
2
Cleared 510(K)
K
11
0834
AW VOLUMESHARE 5 WITH ANGIOVIZ OPTION
2
Cleared 510(K)
K
11
1024
JETPACK 2.0
2
Cleared 510(K)
K
11
0139
CURVE IMAGE
2
Cleared 510(K)
K
11
0844
SYMBIA.NET
2
Cleared 510(K)
K
10
3565
MEDVOXEL HEARTPRO SOFTWARE APPLICATION
2
Cleared 510(K)
K
11
0667
IMAGE-ARENA AND IMAGE-ARENA APPLICATIONS
2
Cleared 510(K)
K
11
0595
4D SONO-SCAN 1.0
2
Cleared 510(K)
K
11
0186
SYNAPSE 3D LIVER ANALYSIS
2
Cleared 510(K)
K
11
0494
SYNGO MBF
2
Cleared 510(K)
K
11
0332
CLEARCANVAS RIS / PACS
2
Cleared 510(K)
K
10
3546
AYCAN WORKSTATION OSIRIX PRO
2
Cleared 510(K)
K
11
0108
MODALIXX
2
Cleared 510(K)
K
10
3720
SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS
2
Cleared 510(K)
K
11
0511
E4D COMPASS
2
Cleared 510(K)
K
10
3480
THORACIC VCAR
2
Cleared 510(K)
K
10
3792
BARCO MAMMO TOMOSYNTHESIS
2
Cleared 510(K)
K
10
3687
SYNAPSE 3D CEREBRAL ANALYSIS
2
Cleared 510(K)
K
10
3458
VIEWPOINT 6
2
Cleared 510(K)
K
10
3679
AXIS PACS, HMS PACS
2
Cleared 510(K)
K
10
3576
MIM 5.2 (BRACHY)
2
Cleared 510(K)
K
10
3761
VISUALIZE: VASCULAR
2
Cleared 510(K)
K
10
3785
MOBILE MIM
2
Cleared 510(K)
K
10
1842
ACIES
2
Cleared 510(K)
K
10
1398
STEREOS WORKSTATION
2
Cleared 510(K)
K
10
3385
SECURVIEW DX DIAGNOSTIC WORKSTATION
2
Cleared 510(K)
K
11
0071
COR ANALYZER
2
Cleared 510(K)
K
10
3465
SYNAPSE 3D CARDIAC TOOLS
2
Cleared 510(K)
K
11
0077
NEUCOLONCARE
2
Cleared 510(K)
K
11
0040
OMNIVISION
2
Cleared 510(K)
K
10
3815
Q-STATION
2
Cleared 510(K)
K
10
3182
TRIANA, PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
2
Cleared 510(K)
K
10
3475
SPINEANALYER MODEL SAPOC
2
Cleared 510(K)
K
10
0372
SAFECT MODEL VER 1.0
2
Cleared 510(K)
K
10
0837
PACENTRIC CONNECT, TRAVELER AND WEB
2
Cleared 510(K)
K
10
2849
ACCULMAING
2
Cleared 510(K)
K
09
2728
20.1 INCH (51 CM) COLOR LCD MONITOR CCL208 (CDL2013A)
2
Cleared 510(K)
K
10
1654
IMPROVIS IMAGING SYSTEM
2
Cleared 510(K)
K
10
1707
FULACCESS MODEL 1.0
2
Cleared 510(K)
K
10
2435
BEYONDIMAGE WORKSTATION
2
Cleared 510(K)
K
10
2000
IMAGYS
2
Cleared 510(K)
K
10
2556
VOLPARA, VERSION 1.3
2
Cleared 510(K)
K
10
1166
4D-VIEW 9.1 (4D VIEW PC SOFTWARE) MODEL: H48651SZ
2
Cleared 510(K)
K
10
2150
SYNGO DYNAMICS, VERSION 9.0
2
Cleared 510(K)
K
10
1324
GE ECHOPAC MODEL BT10
2
Cleared 510(K)
K
10
2687
MIRADA RT
2
Cleared 510(K)
K
10
2684
XELIS DENTAL
2
Cleared 510(K)
K
10
1311
EP NAVIGATOR R3
2
Cleared 510(K)
K
10
1697
ENSITE VERISMO SEGMENTATION TOOL V.2.0
2
Cleared 510(K)
K
10
0793
UROSTATION 3D PROSTATE SUITE
2
Cleared 510(K)
K
10
1342
OSIRIX MD
2
Cleared 510(K)
K
09
3269
PROCEDURE REHEARSAL STUDIO
2
Cleared 510(K)
K
10
2148
CURIEPACS (DICOM PACS SOFTWARE)
2
Cleared 510(K)
K
10
1749
SYNGO TRUED SOFTWARE
2
Cleared 510(K)
K
09
0947
21.3 (54 CM) MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR, MODEL MS3112 (MDL2128A)
2
Cleared 510(K)
K
10
1666
SYNGO. PLAZA VA20A
2
Cleared 510(K)
K
10
1279
CORRIDOR4DM V2010 MODEL: V2010
2
Cleared 510(K)
K
10
1662
SYNAPSE 3D BASIC TOOLS
2
Cleared 510(K)
K
09
2328
MED-SEG, MODEL BTMS 1000
2
Cleared 510(K)
K
10
1796
PACSMATE MMD-5201M MONITOR
2
Cleared 510(K)
K
10
1228
MIRADA XD
2
Cleared 510(K)
K
09
3197
CORONIS FUSION 10MP, MODEL MDCG-10130
2
Cleared 510(K)
K
09
2915
CEDARA WEBACCESS, MODEL: 2.4
2
Cleared 510(K)
K
10
0619
SYMBIA.NET, SYMBIA.NET SELECT MODEL 10520828, 10520827
2
Cleared 510(K)
K
10
0292
CAAS QVA 3D, CAAS QCA 3D
2
Cleared 510(K)
K
09
4064
ILUMA VISION MODEL VERSION 2.2
2
Cleared 510(K)
K
10
0881
SYNAPSE OBLIQUUS MIP/MPR/FUSION
2
Cleared 510(K)
K
10
0335
ORS VISUAL
2
Cleared 510(K)
K
10
0236
STAIR SYSTEMS PACS & DICOM VIEWER
2
Cleared 510(K)
K
09
3603
STORM-BASE 2.0
2
Cleared 510(K)
K
09
2363
SOFTVIEW, MODEL 2.01
2
Cleared 510(K)
K
09
1631
ACCESSNET, ACCESSMED, ACCESSRAD, MEDVIEW
2
Cleared 510(K)
K
09
2427
SPINAL GUIDES PACS (PACS MEDICAL IMAGING DISPLAY WORKSTATION)
2
Cleared 510(K)
K
10
0094
CARESTREAM IMAGE SUITE
2
Cleared 510(K)
K
09
3480
CUATTRO UNOMD
2
Cleared 510(K)
K
09
0050
STEREOS WORKSTATION
2
Cleared 510(K)
K
09
3612
SYNGO.PLAZA
2
Cleared 510(K)
K
09
2613
COLOR LCD MONITOR, MODEL RADIFORCE RS210
2
Cleared 510(K)
K
09
2842
ECHOPLAQUE
2
Cleared 510(K)
K
09
3621
SYNGO.PET&CT ONCOLOGY
2
Cleared 510(K)
K
09
3444
EXAPACS
2
Cleared 510(K)
K
09
3703
3DI
2
Cleared 510(K)
K
09
3982
XELERIS 3 PROCESSING AND REVIEW WORKSTATION
2
Cleared 510(K)
K
09
3355
PCR ELEVA 1.2
2
Cleared 510(K)
K
09
3090
GALILEOS IMPLANT, VERSION 1.7
2
Cleared 510(K)
K
09
3672
AEGIS NAVIGATION ANDA EGIS PELVIC APPLICATION
2
Cleared 510(K)
K
09
3117
DIGITAL LIGHTBOX
2
Cleared 510(K)
K
09
1364
DICOMPACS, MODEL 5.2, DICOMPACS DX-R, MODEL 1.4
2
Cleared 510(K)
K
09
2125
PRESIDIO PACS
2
Cleared 510(K)
K
09
3247
MEDSYNAPSE PACS SOFTWARE
2
Cleared 510(K)
K
09
2639
INNOVA VISION, MODEL S18751VN, INNOVA TRACKVISION, MODEL S18751VT, INNOVA EPVISION, MODEL S18751EP
2
Cleared 510(K)
K
09
3423
LUNGPOINT PROCEDURE PLANNING
2
Cleared 510(K)
K
09
2741
COLOR LCD MONITOR, MODEL RADIFORCE MX241W
2
Cleared 510(K)
K
09
2954
CADSTREAM VERSION 5
2
Cleared 510(K)
K
09
3234
INTEGRATED REGISTRATION
2
Cleared 510(K)
K
09
2581
MITS DICOM GATEWAY AND IMAGE MANAGER
2
Cleared 510(K)
K
09
2949
IMAGEGRID RADIOLOGY VIEWER SYSTEM
2
Cleared 510(K)
K
09
2204
PMD VIEWER
2
Cleared 510(K)
K
09
2067
ABVS WORKPLACE
2
Cleared 510(K)
K
09
2134
STAT PACS PICTURE ARCHIVING & COMMUNICATION SYSTEM (PACS)
2
Cleared 510(K)
K
09
2519
SYNGO.X
2
Cleared 510(K)
K
09
2102
NORDICBRAINEX SOFTWARE, VERSION 1.0
2
Cleared 510(K)
K
09
2235
BEYONDIMAGE WORKSTATION
2
Cleared 510(K)
K
09
2081
QXLINK
2
Cleared 510(K)
K
09
1274
CORONIS 5MP HD, MODEL MDMG 5121
2
Cleared 510(K)
K
09
1687
PACSMATE, MODEL MMD-4300C/MMD-4300CX
2
Cleared 510(K)
K
08
3658
PACS PLUS 5TH EDITION
2
Cleared 510(K)
K
09
1262
MR CARDIAC FUNCTION ANALYSIS
2
Cleared 510(K)
K
09
1001
MYRIAN 1.4
2
Cleared 510(K)
K
09
0668
VISION TOOLS
2
Cleared 510(K)
K
08
3520
INTELEPACS, MODEL VERSION 3.X.X
2
Cleared 510(K)
K
09
1032
CERNER PROVISION WORKSTATION (VERSION 2.5)
2
Cleared 510(K)
K
09
0431
DEXIS SOFTWARE
2
Cleared 510(K)
K
09
0546
MODIFICATION TO NORDICICE SOFTWARE
2
Cleared 510(K)
K
09
1498
VITREA ENDOVASCULAR STENT PLANNING SOFTWARE
2
Cleared 510(K)
K
09
1368
R2 DIGITALNOW HD(DIGITALNOW HD)
2
Cleared 510(K)
K
09
0461
IMAGE-ARENA 4.0 AND IA APPLICATIONS 2D CARDIAC PERFORMANCE ANALYSIS 1.0
2
Cleared 510(K)
K
09
0155
CAAS MR FLOW 1.0
2
Cleared 510(K)
K
09
1373
SYNGO TRUED
2
Cleared 510(K)
K
08
3327
SYNGOCIRCULATION DYNAMICPET, VERSION 1.0
2
Cleared 510(K)
K
09
1286
SYNGO US WORKPLACE
2
Cleared 510(K)
K
09
0833
SEGMENT
2
Cleared 510(K)
K
09
1172
NIO 2MP (MDNG-2121)
2
Cleared 510(K)
K
09
1160
LUNGPOINT VIRTUAL BRONCHOSCOPIC NAVIGATION VBN SYSTEM
2
Cleared 510(K)
K
09
0607
BLUE SKY BIO PLAN, VERSION .38
2
Cleared 510(K)
K
09
0603
BARCO 5MP MAMMO, MODEL MDMG-5221
2
Cleared 510(K)
K
09
0732
NIO COLOR 3MP AND MDNC-3121
2
Cleared 510(K)
K
09
0218
MD213MC 21.3 DIAGNOSTIC IMAGING LCD MONITOR MODEL, L218TJ
2
Cleared 510(K)
K
09
0215
MD213MG 21.3 DIAGNOSTIC IMAGING LCD MONITOR - L218TL
2
Cleared 510(K)
K
08
3910
VIDISTAR PACS & DICOM VIEWER SOFTWARE SERVER SOFTWARE SYSTEM, HEART VIEW, STANDALONE VIEWER
2
Cleared 510(K)
K
09
0223
ICAD BREAST INTERVENTIONAL PLANNING SOFTWARE, MODEL D70024
2
Cleared 510(K)
K
08
3446
CARDIAC FUNCTION ANALYSIS, CALCIUM SCORING
2
Cleared 510(K)
K
09
0649
VRAD PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM SOFTWARE
2
Cleared 510(K)
K
08
1168
BRIT PACS SYSTEMS
2
Cleared 510(K)
K
09
0481
DEMASQ IMAGING SPFTWARE DEVICE
2
Cleared 510(K)
K
09
0552
UROCARE
2
Cleared 510(K)
K
09
0095
LUNGPOINT VIRTUAL BRONCHOSCOPIC NAVIGATION VBN SYSTEM
2
Cleared 510(K)
K
09
0295
BODYVIZ, MODEL 100
2
Cleared 510(K)
K
08
3182
DATACOM DC PACS
2
Cleared 510(K)
K
08
3691
BONEVUE
2
Cleared 510(K)
K
08
2623
VISIX IMAGING
2
Cleared 510(K)
K
08
2693
RESOLUTIONMD, RELEASE 2.1
2
Cleared 510(K)
K
08
3491
NEUROSCAPE
2
Cleared 510(K)
K
08
3740
MAMMODIAGNOST VU
2
Cleared 510(K)
K
09
0119
SICAT IMPLANT
2
Cleared 510(K)
K
08
1556
CADSTREAM, VERSION 5.0
2
Cleared 510(K)
K
09
0045
COLOR LCD MONITOR, RADIFORCE RX320
2
Cleared 510(K)
K
08
3618
PACS SCAN
2
Cleared 510(K)
K
08
3916
LCD3090WQXI OR MD304MC 29.8 INCH DIAGNOSTIC IMAGING LCD MONITOR, MODEL L307TD
2
Cleared 510(K)
K
08
3149
ARTERIAL HEALTH PACKAGE (AHP) SOFTWARE
2
Cleared 510(K)
K
08
3907
MD212MC 21.3 DIAGNOSTIC IMAGING LCD MONITOR-L217TG
2
Cleared 510(K)
K
08
3332
MD21M 21.3 DIAGNOSTIC IMAGING LCD MONITOR, MODEL L218TK
2
Cleared 510(K)
K
08
2808
IMAGESVR PACS
2
Cleared 510(K)
K
08
2526
CARDIO VUE QUANTITATIVE ANALYSIS (CVQ)
2
Cleared 510(K)
K
08
3673
CARESTREAM PACS, MODEL CARESTREAM PACS VII
2
Cleared 510(K)
K
08
3348
IMAGE-ARENA APPLICATIONS
2
Cleared 510(K)
K
08
3084
CT BRAIN PERFUSION FOR ZIOSTATION
2
Cleared 510(K)
K
08
3555
PICTURE ARCHIVING AND COMMUNICATION SYSTEM (PACS), PETAVISION
2
Cleared 510(K)
K
08
2269
VISAGE PACS, VERSION 6.0/CS 3.1
2
Cleared 510(K)
K
08
2607
MRI-PLAQUE VIEW, VERSION 1.1.2003
2
Cleared 510(K)
K
08
2441
NORDICICE SOFTWARE
2
Cleared 510(K)
K
08
2990
INFINITT XELIS
2
Cleared 510(K)
K
08
2628
CMR42 CARDIAC MRI IMAGING SYSTEM, 2.1.23
2
Cleared 510(K)
K
08
2240
SNTRYPACS
2
Cleared 510(K)
K
08
3018
CENTRICITY PACS WEB DIAGNOSTIC
2
Cleared 510(K)
K
08
2430
SYNGO IMAGING XS
2
Cleared 510(K)
K
08
2706
INFINITT CARDIOLOGY PACS
2
Cleared 510(K)
K
08
2493
MEDICAL DISPLAY, MD205MG-1
2
Cleared 510(K)
K
08
2135
SHOWCASE
2
Cleared 510(K)
K
08
2336
XR-EXPRESS
2
Cleared 510(K)
K
08
2684
4D VIEWER RADIOLOGY, MODEL USWP-100A
2
Cleared 510(K)
K
08
2663
COLOR LCD MONITOR
2
Cleared 510(K)
K
08
2510
IMAGE-ARENA APPLICATIONS, MODEL IMAGE-ARENA VA PLATFORM 1.0, 4D LV-ANALYSIS 2.5, 4D LV-ANALYSIS MR 1.0
2
Cleared 510(K)
K
08
1987
UNISYN IMAGE FUSION, VERSION 1.0
2
Cleared 510(K)
K
08
1985
AW SERVER
2
Cleared 510(K)
K
08
2596
ULTRAEXTEND USWS-900A
2
Cleared 510(K)
K
08
2228
PLANISIGHT LINASYS
2
Cleared 510(K)
K
08
1948
RAYPAX SYSTEM
2
Cleared 510(K)
K
08
1792
SPY ANALYSIS TOOLKIT, MODEL SA9000
2
Cleared 510(K)
K
08
2386
INREACH PLANNING LAPTOP
2
Cleared 510(K)
K
08
2483
QUANTRA
2
Cleared 510(K)
K
08
1945
21.3-INCH (54CM) MONOCHROME LCD MONITOR MS21I2 (MDL2127A)
2
Cleared 510(K)
K
08
1656
VISUALASE THERMAL THERAPY SYSTEM
2
Cleared 510(K)
K
08
2496
PACSMATE MMD-3213M MONITOR
2
Cleared 510(K)
K
08
2144
AMICAS PACS, VERSION 6.0
2
Cleared 510(K)
K
08
1357
5MP GRAYSCALE FLAT PANEL DISPLAY, MODEL, 6GF6201-5C$2# (WHERE $ = A-Z AND # = 0-9)
2
Cleared 510(K)
K
08
0196
Z3D CONTRAST ACUITY
2
Cleared 510(K)
K
08
2341
DSA 2000EX
2
Cleared 510(K)
K
08
0529
STEREOS WORKSTATION
2
Cleared 510(K)
K
08
1215
VOLUMINA
2
Cleared 510(K)
K
08
2318
CENTRICITY PACS IW
2
Cleared 510(K)
K
08
1672
C-INSIGHT
2
Cleared 510(K)
K
08
1752
EDGE PACS
2
Cleared 510(K)
K
08
2041
FIATLUX VISUALIZE
2
Cleared 510(K)
K
08
1630
MAMMO WORKSTATION
2
Cleared 510(K)
K
08
1976
IMPAX MA3000 DIAGNOSTIC PACS WORKSTATION
2
Cleared 510(K)
K
08
1512
STEALTHVIZ ADVANCED PLANNING APPLICATION WITH STEALTHDTI PACKAGE
2
Cleared 510(K)
K
08
1402
SIMPLANT ORTHO ; VISTADENT 3D
2
Cleared 510(K)
K
08
0905
QUANTUM/ CANON CXDI INTEGRATION SYSTEM, MODEL QG-DIG-CXDI
2
Cleared 510(K)
K
08
1843
ULTRASOUND DATA ANALYSIS SYSTEM, MODEL DAS-RS1
2
Cleared 510(K)
K
08
1734
SYNGO IMAGING (VERSION V31)
2
Cleared 510(K)
K
08
1076
VELOCITYAIS, VELOCITY AI, VELOCITYVX, VELOCITYRT, V-RESPONSE
2
Cleared 510(K)
K
08
1262
DC NEURO
2
Cleared 510(K)
K
08
1469
SECTRA WORKSTATION, IDS7 VERSION 11.3, IDS5 VERSION 11.1 P2
2
Cleared 510(K)
K
08
1304
ALZ WEB PACS, VERSION 1.0
2
Cleared 510(K)
K
08
1242
21.3 INCH (53CM) MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS51I2, (MDL2123A)
2
Cleared 510(K)
K
08
1308
FUJIFILM FCR VIEW, MODEL CR-VW674
2
Cleared 510(K)
K
08
1056
21.3 (54CM) 3M COLOR LCD MONITOR CCL354I2 (CDL2126A)
2
Cleared 510(K)
K
08
1055
21.3 (54CM) 2M COLOR LCD MONITOR CCL254I2 (CDL2125A)
2
Cleared 510(K)
K
08
0951
19-INCH (48CM) 1.3M COLOR LCD MONITOR CDL1909A
2
Cleared 510(K)
K
08
0952
15-INCH (38 CM) COLOR LCD MONITOR CDL1576A
2
Cleared 510(K)
K
08
1347
ILUMA VISION
2
Cleared 510(K)
K
07
2258
BI-RADS COMPANION
2
Cleared 510(K)
K
08
1109
CORONIS 5MP MAMMO SL, MODEL MDMG 6121
2
Cleared 510(K)
K
08
1093
3-D IMAGING WORKSTATION
2
Cleared 510(K)
K
08
0890
SMARTSPOT PRIMAX
2
Cleared 510(K)
K
08
1018
SYNGO DYNAMICS VERSION 7.0
2
Cleared 510(K)
K
07
3358
LUMIMED SERIES 5MP DIGITAL FLAT PANEL DISPLAY SYSTEM, MODEL MM50/MM50A
2
Cleared 510(K)
K
08
0351
DEXELA DEX TOP MAMMOGRAPHY WORKSTATION, MODEL MAMWKVI
2
Cleared 510(K)
K
07
2728
SYNGO MULTIMODALITY WORKPLACE
2
Cleared 510(K)
K
08
0961
NM APPLICATION SUITE
2
Cleared 510(K)
K
08
0608
DIGITAL LIGHTBOX
2
Cleared 510(K)
K
07
3449
SURGICASE
2
Cleared 510(K)
K
08
0770
IMAGENMD WITH IMAGENQ
2
Cleared 510(K)
K
08
0325
IGROK
2
Cleared 510(K)
K
07
3468
MIMICS
2
Cleared 510(K)
K
08
0457
COLOR LCD MONITOR, MODEL RADIFORCE RX211
2
Cleared 510(K)
K
07
3714
TRAUMACAD VERSION 2.0
2
Cleared 510(K)
K
07
3176
KANTERON DICOM STATION (KDS), MODEL 3.0
2
Cleared 510(K)
K
07
3526
AMICAS VISION SERIES PACS, MODEL 5.5
2
Cleared 510(K)
K
08
0422
5 MEGAPIXEL MONOCHROME LCD MONITOR, MODEL RADIFORCE GS520
2
Cleared 510(K)
K
07
3062
OMNI-VUE SYSTEM
2
Cleared 510(K)
K
07
3418
SYNGO IMAGING CCF VA10A
2
Cleared 510(K)
K
08
0333
IMAGEGRID
2
Cleared 510(K)
K
08
0290
XVIEWNET
2
Cleared 510(K)
K
08
0334
INSTARAD
2
Cleared 510(K)
K
08
0320
PRIMEVUE 21 3MP COLOR DISPLAY, MODEL AC-QX21-A9300
2
Cleared 510(K)
K
07
3704
I-DIXEL
2
Cleared 510(K)
K
07
2821
VITREA 4DCT
2
Cleared 510(K)
K
07
3194
CMRTOOLS AND PLUG-INS VENTRICULAR TOOLS & THALASSAEMIA TOOLS
2
Cleared 510(K)
K
07
3007
CORONIS FUSION 6MP DL, MODEL: MDCC 6130 DL
2
Cleared 510(K)
K
07
1794
15M MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MDL2123A (MS51I2)
2
Cleared 510(K)
K
07
2653
3VISEON/SURGERY
2
Cleared 510(K)
K
07
2875
NIO 5MP DISPLAY, MODEL E5620
2
Cleared 510(K)
K
07
3292
MM/MMA/COLOR SERIES DIGITAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
08
0013
REGISTRATION AND FUSION
2
Cleared 510(K)
K
07
3169
SCIMAGE PICOMENTERPRISE
2
Cleared 510(K)
K
07
3306
XORANCONNECT
2
Cleared 510(K)
K
07
3448
MEDICAL DISPLAY, MD205MG
2
Cleared 510(K)
K
07
3259
XIDF-100A/B1 IMAGE PROCESSOR
2
Cleared 510(K)
K
07
3340
COLOR LCD MONITOR, FLEXSCAN MX300W
2
Cleared 510(K)
K
07
3205
NIO 5MP, MODEL MDNG-5121
2
Cleared 510(K)
K
07
3272
WORKSTATIONONE BREAST IMAGING WORKSTATION
2
Cleared 510(K)
K
07
2637
DIVO
2
Cleared 510(K)
K
07
3271
ORTHOGON
2
Cleared 510(K)
K
07
2986
INTEGRADWEB PACS SYSTEM
2
Cleared 510(K)
K
07
2952
GE ECHOPAC
2
Cleared 510(K)
K
07
2960
CDP 5000, MEDIA AND DISTRIBUTION CENTER, DIAGNET
2
Cleared 510(K)
K
07
2972
MEDSTREAMING MEDICAL OFFICE SOFTWARE
2
Cleared 510(K)
K
07
2532
TRUEPIX LCD MEDICAL DISPLAY MONITOR, MODELS TX-5M, TX-3M, TX-2M
2
Cleared 510(K)
K
07
2665
SUNIRAY 5.2
2
Cleared 510(K)
K
07
1964
MIM 4.1 (SEASTAR)
2
Cleared 510(K)
K
07
2242
COR ANALYZER II, MODEL V1.7
2
Cleared 510(K)
K
07
1584
OASIS RELEASE 1.0
2
Cleared 510(K)
K
07
2205
VISAGE PACS/CS, RELEASE VERSION 5.0
2
Cleared 510(K)
K
07
1492
FIRSTVIEW
2
Cleared 510(K)
K
07
1894
XEBRA DICOM IMAGE BROWSER
2
Cleared 510(K)
K
07
2065
20.8-INCH (53CM) COLOR LCD MONITOR CDL2119A (CCL352I2)
2
Cleared 510(K)
K
07
2066
1.3M MONOCHROME LCD MONITOR MDL1908A
2
Cleared 510(K)
K
07
1636
CODIAGNOSTIX (R) 5.72
2
Cleared 510(K)
K
06
3066
AXIS-V MONOCHROME 5 MP DISPLAY
2
Cleared 510(K)
K
07
1972
ORTHOPEDIC SOFTWARE FOR IMPAX WORKSTATIONS
2
Cleared 510(K)
K
07
1950
SYNGO TRUED
2
Cleared 510(K)
K
07
1602
IMAGIC V2.0
2
Cleared 510(K)
K
07
1166
UNIWEB, VERSION 5.0
2
Cleared 510(K)
K
07
1599
EASYGUIDE
2
Cleared 510(K)
K
07
1436
REGIUS UNITEA
2
Cleared 510(K)
K
06
2878
EZPACS, VERSION 3.0
2
Cleared 510(K)
K
07
1297
IMPAX SE SIGMACOM CLIENT (PACS WORKSTATION)
2
Cleared 510(K)
K
07
1232
IMAGE-ARENA APPLICATIONS AND RESEARCH-ARENA APPLICATIONS
2
Cleared 510(K)
K
07
1241
LMS-LIVER
2
Cleared 510(K)
K
07
1086
RESOLUTIONMD CARDIAC PRODUCT FAMILY, MODEL: RELEASE 1.0
2
Cleared 510(K)
K
07
1362
VITAL CONNECT 4.1
2
Cleared 510(K)
K
07
1331
VITREA VERSION 4.0
2
Cleared 510(K)
K
06
3269
5MP MEDICAL MONOCHROME REFERENCE DISPLAY, MODEL MDM2010-5NC
2
Cleared 510(K)
K
07
1114
SYNGO IMAGING (VERSION V30)
2
Cleared 510(K)
K
07
1054
RADIODEXTER, DEXTROSCOPE, DEXTROBEAM, MODELS 1.0, MK10, MK3 & MK4
2
Cleared 510(K)
K
07
0831
VOXAR 3D ENTERPRISE WITH COLONMETRIX AND PET/CT PERFUSION
2
Cleared 510(K)
K
07
0868
LMS-LUNG/TRACK
2
Cleared 510(K)
K
07
1000
MYRIAN
2
Cleared 510(K)
K
07
0755
INTERWORKS
2
Cleared 510(K)
K
07
0726
NIO COLOR 3MP AND MDNC 3120
2
Cleared 510(K)
K
07
0713
IMPLANT LOCATION SOFTWARE-T
2
Cleared 510(K)
K
06
3391
SAPHENEIA CLARITY
2
Cleared 510(K)
K
07
0618
DICOMPACS, MODEL 5
2
Cleared 510(K)
K
07
0606
VISIO+CD VIEWER# KPSCDVE01
2
Cleared 510(K)
K
07
0954
PATIENTGALLERY IMAGING SOFTWARE
2
Cleared 510(K)
K
07
0397
DGSCOPE, RELEASE 1.0
2
Cleared 510(K)
K
07
0683
MIRAGE CEDARS OPTION
2
Cleared 510(K)
K
07
0803
INVIVODENTAL
2
Cleared 510(K)
K
07
0796
CHILI PACS
2
Cleared 510(K)
K
07
0792
QLAB QUANTIFICATION
2
Cleared 510(K)
K
07
0394
CERNER PROVISION WORKSTATION
2
Cleared 510(K)
K
07
0205
ZIOSTATION
2
Cleared 510(K)
K
06
2621
NIO 5MP-21 AND MDNG-5121 CB
2
Cleared 510(K)
K
07
0464
ONDEMAND3D
2
Cleared 510(K)
K
07
0370
21.3 INCH (54CM) MONOCHROME LCD MONITOR MDL2122A
2
Cleared 510(K)
K
07
0226
CARDIOCT
2
Cleared 510(K)
K
07
0089
SYNTERMED LIVE
2
Cleared 510(K)
K
07
0248
VELOCITYAIS
2
Cleared 510(K)
K
07
0322
SYNGO DYNAMICS, VERSION 6.0
2
Cleared 510(K)
K
07
0131
RADIFORCE GX220 AND GS220 MONOCHROME LCD MONITORS
2
Cleared 510(K)
K
07
0244
AEGIS
2
Cleared 510(K)
K
07
0122
MONOCHROME LCD MONITOR, MODEL RADIFORCE GX320
2
Cleared 510(K)
K
06
3730
DEXTROSCOPE, MODEL MK10; DEXTROBEAM, MODEL MK3, MK4; RADIODEXTER, MODEL 1.0
2
Cleared 510(K)
K
06
3846
EIGEN DSA 2000
2
Cleared 510(K)
K
07
0080
INTELEPACS
2
Cleared 510(K)
K
06
3294
TOPACS
2
Cleared 510(K)
K
06
3548
COR ANALYZER 1, VERSION 1.4
2
Cleared 510(K)
K
06
3439
MEDICAL IMAGE MANAGEMENT DEVICES FOR VISION TOOLS
2
Cleared 510(K)
K
06
3539
NORDIC IMAGE CONTROL AND EVALUATION (NICE) SOFTWARE, VERSION 2.1
2
Cleared 510(K)
K
06
3826
SYNGO MI APPLICATIONS 2007A
2
Cleared 510(K)
K
06
3781
PHILIPS XD-S DIRECT RADIOGRAPHY WORKSTATION/PACKAGE
2
Cleared 510(K)
K
06
3470
AYCAN WORKSTATION OSIRIX
2
Cleared 510(K)
K
06
2905
NIO FUSION 4MP; MDNC 4130
2
Cleared 510(K)
K
06
3628
CENTRICITY RADIOLOGY RA600, CARDIOLOGY CA1000 AND DIGITAL HARDCOPY
2
Cleared 510(K)
K
06
3579
2MP MEDICAL COLOR REFERENCE DISPLAY, MODEL MDC2130-2HC
2
Cleared 510(K)
K
06
3505
VISUALASE ENVISION SOFTWARE SYSTEM
2
Cleared 510(K)
K
06
3392
IMCO-STAT
2
Cleared 510(K)
K
06
3337
OPAL-RAD
2
Cleared 510(K)
K
06
3253
RCHIVE PACS
2
Cleared 510(K)
K
06
3221
MEDWEB ADVANCED 3D WEB PACS
2
Cleared 510(K)
K
06
3200
20.1-INCH (51CM) COLOR LCD MONITOR CDL2010A (CCL204)
2
Cleared 510(K)
K
06
3153
NOVAPACS
2
Cleared 510(K)
K
06
3199
21.3-INCH (54CM) COLOR LCD MONITOR CDL2120A (CCL252I2)
2
Cleared 510(K)
K
06
3197
21.3 INCH (54CM) MONOCHROME LCD MONITOR MDL2118A (ME355I2)
2
Cleared 510(K)
K
06
3198
21.3-INCH (54CM) MONOCHROME LCD MONITOR MDL2121A (ME253I2)
2
Cleared 510(K)
K
06
3188
DEL-IMS
2
Cleared 510(K)
K
06
3344
CAAS QCA 3D
2
Cleared 510(K)
K
06
3327
ORTHOVIEW
2
Cleared 510(K)
K
06
2985
IVUS ENHANCER
2
Cleared 510(K)
K
06
2237
CADI, VERSION 4
2
Cleared 510(K)
K
06
2131
NIO 5MP-M-21 (NIO 5MP MAMMO); MDNG-5121 BB
2
Cleared 510(K)
K
06
3289
2MP MEDICAL MONOCHROME REFERENCE DISPLAY, MODEL MDM2130-2NC
2
Cleared 510(K)
K
06
1696
IQQA-LIVER SOFTWARE
2
Cleared 510(K)
K
06
3267
ISITE PACS, V 4. X
2
Cleared 510(K)
K
06
3266
3MP MEDICAL MONOCHROME REFERENCE DISPLAY, MODEL MDM2130-3NC
2
Cleared 510(K)
K
06
3120
COLOR LCD MONITOR, RADIFORCE, MODEL RX210
2
Cleared 510(K)
K
06
3093
SECTRA WORKSTATION, VERSION 11.1
2
Cleared 510(K)
K
06
2757
XERON PACS
2
Cleared 510(K)
K
06
3031
PRISM VIEW, MODEL
2
Cleared 510(K)
K
06
3006
GE LOGIQ WORKS
2
Cleared 510(K)
K
06
2743
UNISIGHT MAMMOGRAPHY VIEWER, MODEL 4.0
2
Cleared 510(K)
K
06
2598
IMT.LAB SOFTWARE
2
Cleared 510(K)
K
06
3107
3DNET SUITE
2
Cleared 510(K)
K
06
2490
VISAGE PACS/CS, RELEASE VERSION 4.1
2
Cleared 510(K)
K
06
2477
AMICAS VISION SERIES PACS, MODEL 4.3
2
Cleared 510(K)
K
06
0836
VISTADENT OC - VERSION 4
2
Cleared 510(K)
K
06
3037
CENTARISONE RIS/PACS
2
Cleared 510(K)
K
06
2054
5 MEGAPIXEL MONOCHROME LCD MONITOR, RADIFORCE GS510
2
Cleared 510(K)
K
06
2031
CHASE CARDIAC ANALYSIS SYSTEM
2
Cleared 510(K)
K
06
2163
MIMVIEWER
2
Cleared 510(K)
K
06
2164
RESOLUTIONMD, VERSION 1.3
2
Cleared 510(K)
K
06
2650
EP NAVIGATOR SOFTWARE
2
Cleared 510(K)
K
06
2488
IQ-SYSTEM PACS SYSTEM
2
Cleared 510(K)
K
06
1972
CONNECT IMAGING PACS
2
Cleared 510(K)
K
06
1532
GENTLE COLON (REVISION 2.0)
2
Cleared 510(K)
K
06
2229
CTC WORKSTATION, MODEL 2200
2
Cleared 510(K)
K
06
2062
VOYAGER PACS SYSTEM
2
Cleared 510(K)
K
06
2059
AIE REGION OF INTEREST IMAGE ENHANCEMENT
2
Cleared 510(K)
K
06
1995
XCELERA
2
Cleared 510(K)
K
06
1961
ART LAB SOFTWARE
2
Cleared 510(K)
K
06
1924
CORONIS 3MP AND MDCG 3120-CB
2
Cleared 510(K)
K
06
1927
CORONIS COLOR 3MP AND MDCC 3120-DL
2
Cleared 510(K)
K
06
1928
CORONIS COLOR 2MP AND MDCC 2121
2
Cleared 510(K)
K
06
2328
VITREAACCESS, VERSION 1.0
2
Cleared 510(K)
K
06
1920
NOVAPACS, NOVAVIEW, NOVACARDIO, NOVAQC AND NOVAER
2
Cleared 510(K)
K
06
2107
SECURVIEW DX DIAGNOSTIC WORKSTATION, MODELS SV-0001, SV-0002 AND SV-0003
2
Cleared 510(K)
K
06
1926
CORONIS 2MP AND MDCG 2121 - CB
2
Cleared 510(K)
K
06
2154
VITAL CONNECT 4.0
2
Cleared 510(K)
K
06
1855
NEUROQUANT
2
Cleared 510(K)
K
06
2053
MONOCHROME LCD MONITOR, RADIFORCE, GS320
2
Cleared 510(K)
K
06
1964
SYNGO MULTIMODALITY WORKPLACE
2
Cleared 510(K)
K
06
1947
21.3 INCH MONOCHROME LCD MONITOR
2
Cleared 510(K)
K
06
1421
ERAD PACS
2
Cleared 510(K)
K
06
1447
5M MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MDL2116A (ME551I2)
2
Cleared 510(K)
K
06
1418
QUANTIVA
2
Cleared 510(K)
K
06
1672
SYNAPSE MIP/MPR IMAGE VISUALIZATION SOFTWARE OBLIQUUS
2
Cleared 510(K)
K
06
1671
SYNGO TRUED, MODEL VC10A
2
Cleared 510(K)
K
06
1624
VITREA, VERSION 3.9
2
Cleared 510(K)
K
06
1472
GALILEOS IMPLANT, V 1.0
2
Cleared 510(K)
K
06
1160
M-VU CAD STATION
2
Cleared 510(K)
K
06
1061
20.1-INCH (51CM) COLOR LCD MONITOR CDL2009A (CCL204)
2
Cleared 510(K)
K
06
1035
TIGERVIEW PROFESSIONAL
2
Cleared 510(K)
K
06
1396
QLAB QUANTIFICATION SOFTWARE
2
Cleared 510(K)
K
06
1372
CENTRICITY AW SUITE OPTION
2
Cleared 510(K)
K
06
1326
VOXAR 3D ENTERPRISE WITH CARDIAMETRIX
2
Cleared 510(K)
K
06
1303
MEDICAL DISPLAY, MODELS MDM 1900-1NG AND MDM 1900-1NR
2
Cleared 510(K)
K
06
1305
MEDICAL DISPLAY, MDC1900-1LG (1LR)
2
Cleared 510(K)
K
06
0950
3MATIC
2
Cleared 510(K)
K
06
0816
MIM 4.0 (NEURO
2
Cleared 510(K)
K
06
1214
AQUARIUSAPS SERVER
2
Cleared 510(K)
K
06
1126
ACCUREX
2
Cleared 510(K)
K
06
1029
JETSTREAM WORKSPACE
2
Cleared 510(K)
K
06
0961
15-INCH (38CM) COLOR LCD MONITOR CDL1566A
2
Cleared 510(K)
K
06
1018
PLANAR DOME EX LINE MODEL DOME E2C
2
Cleared 510(K)
K
06
0992
SYNGO US WORKPLACE
2
Cleared 510(K)
K
06
0845
MONOCHROME LCD MONITOR, RADIFORCE MODEL GS310
2
Cleared 510(K)
K
06
0941
CAAS MRV VERSION 3.0
2
Cleared 510(K)
K
06
0840
SVIEW
2
Cleared 510(K)
K
05
2424
MAXILIM
2
Cleared 510(K)
K
06
0505
VOXAR 3D ENTERPRISE, MODEL 6.1
2
Cleared 510(K)
K
06
0451
M-VU VIEWER STATION
2
Cleared 510(K)
K
06
0267
VIRTUAL IMPLANT PLACEMENT (VIP) DENTAL IMPLANT SURGERY PLANNING SOFTWARE
2
Cleared 510(K)
K
06
0263
IQPACS
2
Cleared 510(K)
K
06
0453
AZE VIRTUALPLACE
2
Cleared 510(K)
K
06
0378
VITREA2 VERSION 3.8.1
2
Cleared 510(K)
K
06
0035
MDXNET
2
Cleared 510(K)
K
05
3039
CLINTON ELECTRONICS SERIES II DIGITAL GRAYSCALE MONITORS, MODELS DL2000, DL3000, DL2000 OF AND DL3000 OF
2
Cleared 510(K)
K
05
3183
JIVE X SOFTWARE
2
Cleared 510(K)
K
06
0210
MEDIPORT
2
Cleared 510(K)
K
05
3592
SIMPLANT DR. JAMES
2
Cleared 510(K)
K
06
0055
KODAK PACS
2
Cleared 510(K)
K
05
3301
CEDARA I-RESPONSE CEDARA PET/CT
2
Cleared 510(K)
K
06
0136
PLANAR DOME EX SERIES DIGITAL FLAT-PANEL DISPLAY SYSTEM, MODEL E4C COLOR
2
Cleared 510(K)
K
05
3455
ENCOMPASS.NET
2
Cleared 510(K)
K
05
3347
KODAK CARESTREAM PACS
2
Cleared 510(K)
K
05
2988
CAAS
2
Cleared 510(K)
K
05
2942
21.3INCH MONOCHROME LCD MONITOR
2
Cleared 510(K)
K
05
3458
WEB1000
2
Cleared 510(K)
K
05
2467
BRAIN VIEWRX VIEWER, VERSION 1.0
2
Cleared 510(K)
K
05
2120
LUMIMED MONOCHROME LCD MONITOR, MODELS MM 20, MM 30 AND MM50
2
Cleared 510(K)
K
05
2632
VITREA2 VERSION 3.8 MEDICAL IMAGE PROCESSING SOFTWARE
2
Cleared 510(K)
K
05
3162
DEXTROSCOPE & DEXTROBEAM
2
Cleared 510(K)
K
05
3281
EVMS (ENTERPRISE VISUAL MEDICAL SYSTEM SOFTWARE)
2
Cleared 510(K)
K
05
3133
SYNGO DYNAMICS, VERSION 5.0
2
Cleared 510(K)
K
05
2963
MEDIQ VERSION 1.0
2
Cleared 510(K)
K
05
3155
VIMPLANT
2
Cleared 510(K)
K
05
3010
VISTADENT AT COMPLETE, MODEL 3.1
2
Cleared 510(K)
K
05
3043
ENCOMPASS SOFTWARE PACKAGE
2
Cleared 510(K)
K
05
2618
IMAGECAST PACS
2
Cleared 510(K)
K
05
2958
COLOR NIO 2MP, E-2320 C
2
Cleared 510(K)
K
05
2537
CATELLA DIAGNOSTIC WORKSTATION, VERSION 4.0
2
Cleared 510(K)
K
05
2995
ADVANTAGE WORKSTATION 4.3.
2
Cleared 510(K)
K
05
2545
INFINITT G3 PACS
2
Cleared 510(K)
K
05
2775
SYNGO MULTIMODALITY WORKPLACE (SYNGO MM WP)
2
Cleared 510(K)
K
05
2379
MIM 3.5 (CIRCA)
2
Cleared 510(K)
K
05
2895
FOURSIGHT VIEWTOOL IMAGE VIEWER
2
Cleared 510(K)
K
05
2284
REFORMAT GATEWAY
2
Cleared 510(K)
K
05
2312
WIDE 5MP (MAMMO) LCD MONITOR SYSTEM
2
Cleared 510(K)
K
05
2358
ETIAM STAR PACS COMPONENTS
2
Cleared 510(K)
K
05
2529
E-2320 PA S
2
Cleared 510(K)
K
05
2352
COLOR CORONIS 2MP-21 AND MFCD 2321
2
Cleared 510(K)
K
05
2478
MFCD 1219, MFCD 1219 TS
2
Cleared 510(K)
K
05
2461
SYNGO IMAGING VERSION V20A
2
Cleared 510(K)
K
05
2199
21.3-INCH(54 CM) MONOCHROME LCD MONITOR MDL2115A (ME353I), (DV3MM-HB), (ME353IM)
2
Cleared 510(K)
K
05
2460
POWERSERVER, POWERREADER, GATEWAY AND POWERCACHE
2
Cleared 510(K)
K
05
2411
HIPAX MEDICAL IMAGING SOFTWARE
2
Cleared 510(K)
K
05
2276
NIO 2MP-20 AND E-2620 S
2
Cleared 510(K)
K
05
2429
CORONIS 3MP-21 AND MFGD 3621
2
Cleared 510(K)
K
05
2403
CORONIS 2MP-21 AND MFGD 2621
2
Cleared 510(K)
K
05
2344
COLOR LCD MONITOR, MODEL RADIOFORCE R31 & R31-C
2
Cleared 510(K)
K
05
2337
MONOCHROME LCD MONITOR, MODEL RADIFORCE G33
2
Cleared 510(K)
K
05
2159
AIDA COMPACT II SYSTEM
2
Cleared 510(K)
K
05
1853
CARDIOSTREAM SONOAIM
2
Cleared 510(K)
K
05
1901
NIO 3MP-21
2
Cleared 510(K)
K
05
1840
ENSITE VERISMO SOFTWARE
2
Cleared 510(K)
K
05
1809
EASYVIZ, EASYVIZ SYSTEM, EASYVIZ PACS SYSTEM, EASYVIZ IMAGE AND DATA MANAGEMENT SYSTEM
2
Cleared 510(K)
K
05
1813
ULTRAPACS
2
Cleared 510(K)
K
05
1902
NIO 2MP-21
2
Cleared 510(K)
K
05
1586
VIEWSEND MEDICAL SYSTEM
2
Cleared 510(K)
K
05
1715
STARPACS DENTAL
2
Cleared 510(K)
K
05
1649
VERICIS CARDIOVASCULAR IMAGE AND INFORMATION SYSTEM, MODEL 4.0
2
Cleared 510(K)
K
05
1639
AS-OBGYN INFORMATION SYSTEM; AS-EMR SYSTEM
2
Cleared 510(K)
K
05
1743
R2 BREAST IMAGING WORKSTATION
2
Cleared 510(K)
K
05
0862
3TP WORKSPACE
2
Cleared 510(K)
K
05
1523
REGIUS CONSOLE CS-2000 AND REGIUS CONSOLE CS-3000, MEDICAL IMAGE PROCESSING WORKSTATION
2
Cleared 510(K)
K
05
1528
MEVIS LIVERANALYSER/LIVERVIEWER SOFTWARE
2
Cleared 510(K)
K
05
1673
XELERIS 2 PROCESSING AND REVIEW WORKSTATION
2
Cleared 510(K)
K
05
1745
ECHOSYSTEM
2
Cleared 510(K)
K
05
1403
19-INCH (48CM) COLOR LCD MONITOR CDL1904A
2
Cleared 510(K)
K
05
1553
FUJI SYNAPSE WORKSTATION SOFTWARE
2
Cleared 510(K)
K
05
1392
BTI-SCAN, VERSION 4.0
2
Cleared 510(K)
K
05
1521
REGIUS RS-1000, MEDICAL IMAGE PROCESSING WORKSTATION
2
Cleared 510(K)
K
05
1037
IMAGEQUBE PACS
2
Cleared 510(K)
K
05
1331
19-INCH (48 CM) COLOR LCD MONITOR CDL1902A
2
Cleared 510(K)
K
05
1325
WEBPAX, MODEL 200
2
Cleared 510(K)
K
05
1315
MODIFICATION TO: SECTRA IDS5 WORKSTATION
2
Cleared 510(K)
K
05
1127
KIKA IMAGING LAB VIEWER, MODEL 2.0.1.0
2
Cleared 510(K)
K
05
1201
E1 MEDICAL FLAT PANEL DISPLAY SYSTEM AND MFGD 1218 MEDICAL FLAT PANEL DISPLAY
2
Cleared 510(K)
K
05
0993
MMS VIDEO OPTION
2
Cleared 510(K)
K
05
0846
B-CAD SYSTEM, VERSION 1.0
2
Cleared 510(K)
K
05
0943
GE VIEWPOINT
2
Cleared 510(K)
K
05
1081
ESSENPACS
2
Cleared 510(K)
K
05
0736
IMORGON ULTRASOUND PACS SOLUTIONS
2
Cleared 510(K)
K
05
0619
20.8-INCH (53CM) COLOR LCD MONITOR, MODELS CDL2112A, CCL350I & DV3MC-HB
2
Cleared 510(K)
K
05
0617
21.3-INCH (54CM) MONOCHROME LCD MONITOR, MODELS MDL2109A, ME251I & DV2MM-HB
2
Cleared 510(K)
K
05
0751
IMPAX ORTHOPAEDIC WORKSTATION, MODEL IMPAX ES 5.X
2
Cleared 510(K)
K
05
0744
KAVO ERGOCOM/ERGOCAM
2
Cleared 510(K)
K
05
0703
QBRAIN
2
Cleared 510(K)
K
05
0616
21.3-INCH (54CM) COLOR LCD MONITOR, MODELS CDL2113A, CCL250I & DV2MC-HB
2
Cleared 510(K)
K
05
0485
20.8-INCH(53CM) MONOCHROME LCD MONITOR MDL2110A (ME351I), (DV3MM-HB)
2
Cleared 510(K)
K
05
0376
PROWIN
2
Cleared 510(K)
K
05
0667
R2 FAMILY OF IMAGE DISPLAY UNITS WITH R2 UNIFORM DISPLAY SOFTWARE
2
Cleared 510(K)
K
05
0341
IMPLANT LOCATION SOFTWARE, MODEL 0.1.0
2
Cleared 510(K)
K
05
0298
IPACS PRISM-5.0
2
Cleared 510(K)
K
05
0196
SECTRA IDS5 WORKSTATION
2
Cleared 510(K)
K
05
0228
AGFA HEARTLAB CARDIOVASCULAR
2
Cleared 510(K)
K
05
0033
LUCION
2
Cleared 510(K)
K
04
2755
MONOCHROME LCD MONITOR, RADIFORCE G51
2
Cleared 510(K)
K
04
3122
SMD 21500 OR DSB-2103-D-5MP-5M PIXEL GRAYSCALE FLAT PANEL DISPLAY
2
Cleared 510(K)
K
04
3483
RADIN, MODEL V 3.0
2
Cleared 510(K)
K
04
3430
20.8-INCH (53 CM) COLOR LCD MONITOR, MODELS CDL2114A AND DV3MC-HB
2
Cleared 510(K)
K
04
3415
CENTRICITY PACS SYSTEM
2
Cleared 510(K)
K
04
3194
VOXAR 3D PRODUCT FAMILY
2
Cleared 510(K)
K
04
3216
CADSTREAM VERSION 4.0
2
Cleared 510(K)
K
04
2868
MAMMOREPORT SOFTCOPY WORKSTATION
2
Cleared 510(K)
K
04
3360
IMT.LAB
2
Cleared 510(K)
K
04
3146
HORIZON MEDICAL IMAGING
2
Cleared 510(K)
K
04
2221
CORONIS 5MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
04
1078
SURGPLAN AND PANPLAN
2
Cleared 510(K)
K
04
3412
MODIFICATION TO: VIEWSTATION
2
Cleared 510(K)
K
04
3350
MISTAR, MODEL V3.2
2
Cleared 510(K)
K
04
3333
VITREA2, VERSION 3.7 MEDICAL IMAGE PROCESSING SYSTEM
2
Cleared 510(K)
K
04
3134
METRX WORKSTATION
2
Cleared 510(K)
K
04
2995
X-LEONARDO
2
Cleared 510(K)
K
04
2353
AXIS I (1MP), II (2MP), III (3MP), AND V (5MP) MONOCHROME DISPLAYS
2
Cleared 510(K)
K
04
2942
MGP 15 DICOM THEATER
2
Cleared 510(K)
K
04
2662
NIO 5MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
04
3097
3VISEON
2
Cleared 510(K)
K
04
2697
SECOND LOOK VIEWER
2
Cleared 510(K)
K
04
2661
NIO 3MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
04
2660
NIO 2MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
04
2816
TRAUMACAD 1.2
2
Cleared 510(K)
K
04
2700
IMAGE MEDICAL ACQUISITION STATION (IMAS)
2
Cleared 510(K)
K
04
2867
PHILIPS ORTHOPAEDIC APPLICATIONS
2
Cleared 510(K)
K
04
2832
SIENET COSMOS (VERSION V15A)
2
Cleared 510(K)
K
04
2212
IMPLANTMASTER
2
Cleared 510(K)
K
04
2383
RSA-CMS
2
Cleared 510(K)
K
04
2781
IPACS CARDIO
2
Cleared 510(K)
K
04
2634
WIDE 1MP LCD MONITOR SYSTEM
2
Cleared 510(K)
K
04
2692
CLARITY FUSION
2
Cleared 510(K)
K
04
2647
EXAM-PACS
2
Cleared 510(K)
K
04
2525
CENTRICITY RADIOLOGY RA600/CENTRICITY CARDIOLOGY CA1000/CENTRICITY DIGITAL HARDCOPY WORKSTATION
2
Cleared 510(K)
K
04
2507
UBIPACS
2
Cleared 510(K)
K
04
2334
ALLURA 3D-CA, RELEASE 1
2
Cleared 510(K)
K
04
2203
LEONARDO SYNGO CARDIOLOGY WORKSTATION
2
Cleared 510(K)
K
04
2042
ULTRASOUND CAPTURE SYSTEM
2
Cleared 510(K)
K
04
2311
PACSPARTNER
2
Cleared 510(K)
K
04
2313
INTEGRADWEB MPR/MIP
2
Cleared 510(K)
K
04
2292
ISITE PACS
2
Cleared 510(K)
K
04
2008
ULTRAVISUAL
2
Cleared 510(K)
K
04
1508
BARCOVIEW CORONIS 5MP HD MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
04
1935
DR SYSTEMS PACS, RELEASE 6.1
2
Cleared 510(K)
K
04
1782
SEEMOR 5.0 IMAGE DISPLAY PROGRAM
2
Cleared 510(K)
K
04
1555
SECURVIEW DX SOFTCOPY WORKSTATION
2
Cleared 510(K)
K
04
1990
FUJI MEDICAL CR CONSOLE, MODEL FLASH IIP
2
Cleared 510(K)
K
04
1484
UNDECIDED
2
Cleared 510(K)
K
04
0686
M'ATH STD
2
Cleared 510(K)
K
04
1682
CAAS MRV
2
Cleared 510(K)
K
04
1326
MEDCOMMONS OPEN RADIOLOGY GATEWAY
2
Cleared 510(K)
K
04
1162
ORTHO-CMS
2
Cleared 510(K)
K
04
0931
PATXFER RT
2
Cleared 510(K)
K
04
0896
MODIFICATION TO ENCOMPASS
2
Cleared 510(K)
K
04
1761
RAPIDIACOLON
2
Cleared 510(K)
K
04
1737
5M MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR ME511L (MDL2105A)
2
Cleared 510(K)
K
04
1029
KINETDX
2
Cleared 510(K)
K
04
0970
LEONARDO
2
Cleared 510(K)
K
04
1597
MONOCHROME LCD MONITOR, MODEL RADIFORCE G22
2
Cleared 510(K)
K
04
1581
COMPACS, VERSION 1.0
2
Cleared 510(K)
K
04
1500
STARPACS ORTHOPEDICS SYSTEM
2
Cleared 510(K)
K
04
0310
NOVA FAMILY OF MEDICAL RADIOLOGY DISPLAYS
2
Cleared 510(K)
K
04
0443
DOME CX DIGITAL FLAT-PANEL DISPLAY SYSTEM, MODEL C5I
2
Cleared 510(K)
K
04
0697
21.3-INCH (54CM) COLOR LCD MONITOR CCL212 (CDL2107A)
2
Cleared 510(K)
K
04
1366
IPACS ORTHO
2
Cleared 510(K)
K
04
0746
MRA-CMS
2
Cleared 510(K)
K
04
0695
21,3-INCH (54CM) MONOCHROME LCD MONITOR ME213L (MDL2108A)
2
Cleared 510(K)
K
03
3859
BARCOVIEW MGD 521M DIGITAL MAMMOGRAPHY DISPLAY
2
Cleared 510(K)
K
04
1270
CT COLONOGRAPHY II
2
Cleared 510(K)
K
04
0555
IMPAX CLIENT EMBRACE
2
Cleared 510(K)
K
03
3849
SIMPLANT SYSTEM
2
Cleared 510(K)
K
04
0982
COLOR LCD MONITOR, MODEL RADIFORCE R12
2
Cleared 510(K)
K
04
0344
IMPAX OT3000 ORTHOPEDIC WORKSTATION
2
Cleared 510(K)
K
03
3912
CRADLE PACS
2
Cleared 510(K)
K
04
0376
SECTRA IDS5 RADIOLOGY WORKSTATION; SECTRA MPR PACKAGE; SECTRA 3D PACKAGE
2
Cleared 510(K)
K
04
0365
COLOR CORONIS 2MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
04
0546
IMAGE-ARENA AND RESEARCH-ARENA APPLICATIONS
2
Cleared 510(K)
K
04
0852
PREVIEW TREATMENT PLANNING SOFTWARE
2
Cleared 510(K)
K
04
0468
CEDARA I-SOFTVIEW AND CEDARA I-READMAMMO
2
Cleared 510(K)
K
03
3153
DICOM THEATER
2
Cleared 510(K)
K
03
1661
5M MEDICAL FLAT PANEL DISPLAY, ME511L
2
Cleared 510(K)
K
03
3006
MIVD 1218 18 INCH GREYSCALE LCD DISPLAY MODULE
2
Cleared 510(K)
K
04
0876
ICONNECTION, VERSION 3.2.0.0 MEDICAL IMAGE PROCESSING SOFTWARE
2
Cleared 510(K)
K
04
0126
VIATRONIX V3D COLON, REVISION 1.3
2
Cleared 510(K)
K
03
3104
MGD 2621P MEDICAL GREYSCALE DISPLAY
2
Cleared 510(K)
K
03
3005
MFGD 1318 18 INCH 1 MEGAPIXEL GREYSCALE LCD DISPLAY
2
Cleared 510(K)
K
03
3103
MGD 2621L MEDICAL GREYSCALE DISPLAY
2
Cleared 510(K)
K
03
3004
MFGD 2320 20 INCH 2 MEGAPIXEL GREYSCALE LCD DISPLAY
2
Cleared 510(K)
K
04
0158
MFCD 2320
2
Cleared 510(K)
K
04
0195
CALYSTO IMAGE IV-IMAGE AND INFORMATION MANAGEMENT SYSTEM
2
Cleared 510(K)
K
04
0399
QONTRAST
2
Cleared 510(K)
K
04
0041
NIO 3MP MEDICAL GRAYSCALE DISPLAY SYSTEM
2
Cleared 510(K)
K
04
0040
NIO 5MP MEDICAL GRAYSCALE DISPLAY SYSTEM
2
Cleared 510(K)
K
04
0050
INSTATRAK SYSTEM WITH MULTIPLE DATASET NAVIGATION, MODEL IT3500
2
Cleared 510(K)
K
04
0039
NIO 2MP MEDICAL GRAYSCALE DISPLAY SYSTEM
2
Cleared 510(K)
K
03
3955
RTIST
2
Cleared 510(K)
K
03
3920
CAAS II RVA
2
Cleared 510(K)
K
04
0486
MEDIPACS
2
Cleared 510(K)
K
03
4059
SECTRA ANGIOGRAPHY PACKAGE AND SECTRA CARDIOLOGY PACKAGE
2
Cleared 510(K)
K
03
2555
3M COLOR MEDICAL FLAT PANEL DISPLAY, CCL316
2
Cleared 510(K)
K
04
0305
VITREA2 VERSION 3.5
2
Cleared 510(K)
K
03
3466
COLOR LCD DISPLAY, MODEL RADIFORCE R22
2
Cleared 510(K)
K
04
0254
INTEGRIS 3D-RA, RELEASE 4.2
2
Cleared 510(K)
K
04
0227
QLAB QUANTIFICATION SOFTWARE
2
Cleared 510(K)
K
04
0142
ENSPHERE TEMPO JETSTREAM WORKSPACE CARDIOLOGY MODULE
2
Cleared 510(K)
K
03
3825
ORTHOPACS
2
Cleared 510(K)
K
03
2531
CHASE CARDIAC ANALYSIS SYSTEM
2
Cleared 510(K)
K
04
0028
CA-1500
2
Cleared 510(K)
K
03
3712
MODIFICATION TO SECTRA IDS5 RADIOLOGY WORKSTATION - VERSION 10.1
2
Cleared 510(K)
K
03
3831
SIENET COSMOS
2
Cleared 510(K)
K
03
3624
PACS SOFTWARE SOLUTION 2003
2
Cleared 510(K)
K
03
3400
SENO ADVANTAGE
2
Cleared 510(K)
K
03
1132
CONSULTIVA CASE INPUT STATION, MODEL CIS-1
2
Cleared 510(K)
K
03
3013
MDIFICATION TO MEDIPRIME
2
Cleared 510(K)
K
03
3361
VIATRONIX V3D VASCULAR, REVISION 1.0
2
Cleared 510(K)
K
03
3093
ECHOCONNEX COMMUNICATOR
2
Cleared 510(K)
K
03
1473
RATIONAL IMAGING PACS
2
Cleared 510(K)
K
03
3088
SECTRA IDS5 RADIOLOGY WORKSTATION VERSION 10.1
2
Cleared 510(K)
K
03
2748
VITREA2, VERSION 3.4 MEDICAL IMAGE PROCESSING SOFTWARE
2
Cleared 510(K)
K
03
2546
HOLOGIC DR IMAGEPRO
2
Cleared 510(K)
K
03
2533
INTELEPACS
2
Cleared 510(K)
K
03
2186
AUTOALIGN
2
Cleared 510(K)
K
03
2924
RADIODEXTER VERSION 1.0, DEXTROSCOPE, MODEL MK10 AND DEXTROBEAM, MODEL MK3
2
Cleared 510(K)
K
03
2960
WIDE 2MP TFT LCD MONITOR SYSTEM IF 1902A
2
Cleared 510(K)
K
03
2324
ECHOENCODER
2
Cleared 510(K)
K
03
1590
SECTRA ORTHOPEDIC PACKAGE
2
Cleared 510(K)
K
03
1567
3D INVIVO BY CSIST
2
Cleared 510(K)
K
03
2176
RATTAN IMACS BY RATTAN INFORMATION CORPORATION
2
Cleared 510(K)
K
03
2157
TELEMIS-MEDICAL SOLUTION
2
Cleared 510(K)
K
03
2760
APAX PACS SYSTEM
2
Cleared 510(K)
K
03
2638
DOME CX DIGITAL FLAT-PANEL DISPLAY SYSTEM MODEL, C3 COLOR AND C3 GRAY
2
Cleared 510(K)
K
03
2020
51CM(20.1INCH) TFT MONOCHROME LCD MONITOR, MU5111BW
2
Cleared 510(K)
K
03
2026
LCD MONITOR, RADIFORCE G11, G31, G51
2
Cleared 510(K)
K
03
2483
VIATRONIX V3D EXPLORER, REVISION 1.2
2
Cleared 510(K)
K
03
2401
ORTHOVIEW
2
Cleared 510(K)
K
03
1836
PHILIPS FRESCO RELEASE 1
2
Cleared 510(K)
K
03
1816
DVNET MDV-PACS
2
Cleared 510(K)
K
03
1562
RAMSOFT PACS, MODEL 3.0
2
Cleared 510(K)
K
03
1778
PRACTICEBUILDER 1-2-3
2
Cleared 510(K)
K
03
1779
CADSTREAM
2
Cleared 510(K)
K
03
2202
DOME CX DIGITAL FLAT-PANEL DISPLAY SYSTEM, MODELS C2 AND C5I
2
Cleared 510(K)
K
03
1704
FILMLESS CLINIC
2
Cleared 510(K)
K
03
2174
WIDE 3MP GRAYSCALE TFT LCD MONITOR IF2103A
2
Cleared 510(K)
K
03
1638
CARDIO VASCULAR INFORMATION ENHANCED WORKSTATION
2
Cleared 510(K)
K
03
2096
PHILIPS VIEWFORUM 2003
2
Cleared 510(K)
K
03
1929
5MP TFT LCD MONITOR SYSTEM IF2105A BY WIDE CORPORATION
2
Cleared 510(K)
K
03
1372
PERSONAL DIGITAL WORKSTATION (PDW); FILM DIGITIZING CAMERA AND DIGITAL WORKSTATION
2
Cleared 510(K)
K
03
1886
SONOVIEW PRO BY MEDISON CO., LTD.
2
Cleared 510(K)
K
03
1311
INTEGRADWEB BY DYNAMIC IMAGING, INC.
2
Cleared 510(K)
K
03
1248
CONSULTIVA REPORT STATION, MODEL RS-1
2
Cleared 510(K)
K
03
0781
KODAK DIRECTVIEW PACS/IMAGE MANAGEMENT SYSTEM, KODAK DIRECTVIEW WORKFLOW MANAGER,KODAK DIRECTVIEW CX/DX, KODAK DIRECTVIB
2
Cleared 510(K)
K
03
0751
IPACS PRISM
2
Cleared 510(K)
K
03
0728
FYRELINK VL
2
Cleared 510(K)
K
03
0347
20.1 MONOCHROME LCD MONITOR, RADIFORCE G20
2
Cleared 510(K)
K
03
0272
FLAT PANEL DISPLAY, ME183L
2
Cleared 510(K)
K
03
0276
FLAT PANEL DISPLAYS, CDL SERIES
2
Cleared 510(K)
K
03
0274
MEDICAL FLAT PANEL DISPLAY, ME315L
2
Cleared 510(K)
K
03
1013
INFINTT CO., LTD. STARPACS SYSTEM
2
Cleared 510(K)
K
03
0982
SYNGO COLONOGRAPHY SOFTWARE PACKAGE
2
Cleared 510(K)
K
03
0457
REX, VERSION 3.0
2
Cleared 510(K)
K
03
0635
THE OBSIDIAN PACS SYSTEM
2
Cleared 510(K)
K
03
0363
ORG@NIZER, MODEL VERSION 3.0
2
Cleared 510(K)
K
02
4358
20.1 MONOCHROME LCD MONITOR, RADIFORCE G21
2
Cleared 510(K)
K
03
0242
FYRELINK
2
Cleared 510(K)
K
02
4159
STRYKERWARE SYSTEM
2
Cleared 510(K)
K
03
0223
SONOCALC
2
Cleared 510(K)
K
02
2877
OBSERVER ULTRASOUND REPORTING AND IMAGING SYSTEM
2
Cleared 510(K)
K
02
4103
IVUS PLUS
2
Cleared 510(K)
K
02
4028
SHARP VIEW IMAGE ENHANCEMENT SYSTEM
2
Cleared 510(K)
K
02
3533
BARCO MEDIS 5MP2 AURA
2
Cleared 510(K)
K
02
4137
JUPITER PROCESSING AND REVIEW WORKSTATION
2
Cleared 510(K)
K
02
3460
PACSPLUS
2
Cleared 510(K)
K
02
3476
UNIPACS WORKSTATION
2
Cleared 510(K)
K
02
3467
HCP DICOM NET
2
Cleared 510(K)
K
02
3394
UNISIGHT SYSTEM WITH UNIGATE
2
Cleared 510(K)
K
02
3877
Q LAB QUANTIFICATION SOFTWARE WITH STRAIN RATE QUANTIFICATION PLUG-IN
2
Cleared 510(K)
K
02
3340
CORONIS 1MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
02
3339
IMAGETILE
2
Cleared 510(K)
K
02
3341
CORNIS 5MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
02
3322
CORONIS 2MP MEDICAL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
02
3246
AMALGA PACS
2
Cleared 510(K)
K
02
3936
MODIFICATION TO MEDIPRIME
2
Cleared 510(K)
K
02
3137
PHILIPS EASYVISION WORKSTATION RELEASE 6
2
Cleared 510(K)
K
02
2773
BARCO MEDIS 2MP1NT MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
02
3772
KINETDX PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
2
Cleared 510(K)
K
02
2970
AMICAS LIGHT BEAM WORKSTATION, MODEL 1.0
2
Cleared 510(K)
K
02
3003
IMAGECHECKER-CT WORKSTATION
2
Cleared 510(K)
K
02
3557
CENTRICITY PACS PLUS
2
Cleared 510(K)
K
02
3440
PHILIPS DIGITAL IMAGING OPTION RELEASE 1
2
Cleared 510(K)
K
02
2938
VIZDEXTER VERSION 2.0; DEXTROSCOPE MK8; DEXTROBEAM MK3
2
Cleared 510(K)
K
02
2788
PHILIPS HARMONY RELEASE 1
2
Cleared 510(K)
K
02
3190
E.CAM COMPUTER / E.SOFT WORKSTATION
2
Cleared 510(K)
K
02
2881
CEDARA I-SOFTVIEW
2
Cleared 510(K)
K
02
2824
ECHO-VIEW 5.X, EASY-VIEW 2.X, OMNI VIEW 2.X, CARDIO-VIEW 1.X, LV ANALYSIS 1.X & SURGICAL VIEW 1.X
2
Cleared 510(K)
K
02
3100
ACCUSKETCH CARDIAC QUANTITATIVE SYSTEM W/ ADVANCED ANALYSIS COMPONENTS
2
Cleared 510(K)
K
02
2940
IN-VISION VIEW WITH MEASUREMENTS MODULE, MODEL 1.0
2
Cleared 510(K)
K
02
2710
SMARTPACS
2
Cleared 510(K)
K
02
2692
VOXELPLUS PACS
2
Cleared 510(K)
K
02
2585
KIMAX QMA
2
Cleared 510(K)
K
02
2896
CSV12 SOFTWARE VIEWER
2
Cleared 510(K)
K
02
2292
IMPAX DIAGNOSTIC DISPLAY STATION,IMPAX CLINICAL REVIEW STATION,IMPAX FOR CARDIOLOGY CLINICAL REVIEW SATATION,IMPAX ORTHO
2
Cleared 510(K)
K
02
2789
VIATRONIX V3D EXPLORER
2
Cleared 510(K)
K
02
1913
CALSCOR SOFTWARE
2
Cleared 510(K)
K
02
1738
FLAT PANEL DISPLAYS, ME SERIES & CCL SERIES
2
Cleared 510(K)
K
02
1934
MODIFICATION TO MEDSTATION
2
Cleared 510(K)
K
02
1583
PATXFER
2
Cleared 510(K)
K
02
2428
QUANTITATIVE BLOOD POOL SPECT (QBS)
2
Cleared 510(K)
K
02
2310
ADVANTAGE WINDOWS X-RAY/MR FUSION
2
Cleared 510(K)
K
02
1236
SURGERY AND ACCESSORIES
2
Cleared 510(K)
K
02
2109
EIZO, MODEL FC-2091
2
Cleared 510(K)
K
02
1191
AUTOALIGN
2
Cleared 510(K)
K
02
0073
MEDICAL ADMINISTRATOR
2
Cleared 510(K)
K
02
1966
Q LAB SOFTWARE
2
Cleared 510(K)
K
02
1314
SCEPTRE-VS
2
Cleared 510(K)
K
02
1099
REX, VERSION 1.0
2
Cleared 510(K)
K
02
1072
FILMSAVER, NT VERSION 5.03
2
Cleared 510(K)
K
02
1669
PHYSICIAN'S DESKTOP REVIEW
2
Cleared 510(K)
K
02
0449
CARDIONOW CARDIOLOGY WIDE AREA ARCHIVE AND RETRIEVAL SYSTEM
2
Cleared 510(K)
K
02
0546
FUSION 7D
2
Cleared 510(K)
K
02
0995
EFILM WORKSTATION WITH MODULES
2
Cleared 510(K)
K
02
0058
MEDICAL LE
2
Cleared 510(K)
K
02
0059
MFCD 118I
2
Cleared 510(K)
K
02
0061
IMAGEDESK
2
Cleared 510(K)
K
02
0658
VIATRONIX V3D COLON
2
Cleared 510(K)
K
02
0483
ADVANTAGE WORKSTATION 4.1
2
Cleared 510(K)
K
01
2439
DENTALEYE 2 DENTAL IMAGE MANAGEMENT SYSTEM
2
Cleared 510(K)
K
01
3994
MODIFICATION TO VIEWSEND MEDICAL
2
Cleared 510(K)
K
02
0140
VOXAR'S CALCIUM SCORING PRODUCT
2
Cleared 510(K)
K
01
3922
CORONIS 3MP MEDICL FLAT PANEL DISPLAY SYSTEM
2
Cleared 510(K)
K
01
3841
3DFIS, MODEL IES-FL-101
2
Cleared 510(K)
K
01
3574
ACCENT
2
Cleared 510(K)
K
01
4058
ENTEGRA PE PERSONAL DIGITAL ASSISTANT
2
Cleared 510(K)
K
01
3419
NICOLET ELECTROMAGNETIC NAVIGATION SYSTEM
2
Cleared 510(K)
K
01
2327
CSIST DICOM GATEWAY/IMAGE MANAGER
2
Cleared 510(K)
K
01
3878
CYBERMED, INC., V-WORKS
2
Cleared 510(K)
K
01
3098
KIMAX REMOTE VIEWING STATION
2
Cleared 510(K)
K
01
3630
ISITE RADIOLOGY
2
Cleared 510(K)
K
01
2844
MAROSIS PACS
2
Cleared 510(K)
K
01
1196
IQUANTIFY, VERSION 1.0
2
Cleared 510(K)
K
01
2779
ICONNECTION 3D
2
Cleared 510(K)
K
01
2563
DEEP GRAY
2
Cleared 510(K)
K
01
2475
CAAS II QVA
2
Cleared 510(K)
K
01
2290
RAPIDIA
2
Cleared 510(K)
K
01
2093
AETMED IMAGE PROCESSING SOFTWARE
2
Cleared 510(K)
K
01
2086
AQUARIUSNET SERVER
2
Cleared 510(K)
K
01
1694
VIEWSTATION
2
Cleared 510(K)
K
01
2155
KODAK RADIATION ONCOLOGY SOFTWARE/ FOR ACR SYSTEMS
2
Cleared 510(K)
K
01
2211
EFILM WORKSTATION
2
Cleared 510(K)
K
01
2099
MONOCHROME PERFECTLY FLAT PANEL DISPLAYS, ME SERIES
2
Cleared 510(K)
K
01
1582
QCU ANALYTICAL SOFTWARE PACKAGE
2
Cleared 510(K)
K
01
2097
VORTEX
2
Cleared 510(K)
K
01
2072
VOXAR VC, MODEL 1.0
2
Cleared 510(K)
K
01
1173
TELEPAX
2
Cleared 510(K)
K
01
0938
SYNGO MULTIMODALITY WORKSTATION
2
Cleared 510(K)
K
00
2911
XSCAN32 TELERADIOLOGY SOFTWARE
2
Cleared 510(K)
K
01
0763
GOODNET
2
Cleared 510(K)
K
01
1142
AQUARIUS WORKSTATION
2
Cleared 510(K)
K
01
0726
MODIFICATION TO MIRAGE
2
Cleared 510(K)
K
01
0259
MEDIFACE PACS
2
Cleared 510(K)
K
01
0271
THINKINGNET
2
Cleared 510(K)
K
01
0571
ADC QS/IPD WORKSTATION
2
Cleared 510(K)
K
01
0058
IMAGE IV DICOM IMAGE ARCHIVAL PACS NETWORK
2
Cleared 510(K)
K
00
2789
MEDEVIEW SYSTEM
2
Cleared 510(K)
K
00
3746
3D-DOCTOR
2
Cleared 510(K)
K
00
3762
ALI 3D TOOL MODULE FOR MEDICAL IMAGES
2
Cleared 510(K)
K
01
0336
ADVANTAGE WINDOWS CT/PET FUSION
2
Cleared 510(K)
K
00
3607
ONYX-RAD TELEMEDICINE PACS
2
Cleared 510(K)
K
00
3510
INSTATRAK SYSTEM WITH FLUOROCAT, MODEL IT3500
2
Cleared 510(K)
K
00
3437
ODYSSEY LX, MODEL 211320
2
Cleared 510(K)
K
00
3688
VIEW READING STATION
2
Cleared 510(K)
K
00
3459
PHILIPS EASY VISION FAMILY WORKSTATION OPTION MR QUANTITATIVE FLOW
2
Cleared 510(K)
K
00
3484
NETRA WORKSTATION AND NETRAMD SOFTWARE
2
Cleared 510(K)
K
00
2942
PHILIPS EASY VISION FAMILY WORKSTATION OPTION CARDIRAC SCORING
2
Cleared 510(K)
K
00
1550
EBT ULTRAFAST CT SCANNER SYSTEM; C-100, C-150, C-150LXP OR C-150XP SCANNER SYSTEMS; ELECTRON BEAM SCANNER SYSTEM; ELECTR
2
Cleared 510(K)
K
00
2894
MEDIPRIME
2
Cleared 510(K)
K
00
2782
HERMES HD AQ ACQUISITION STATION AND HERMES WORKSTATION
2
Cleared 510(K)
K
00
1947
T.I.M.S., VERSION 2.00
2
Cleared 510(K)
K
00
2780
VIATRONIX VISUALIZATION SYSTEM (VVS)
2
Cleared 510(K)
K
00
2724
NUMALINK
2
Cleared 510(K)
K
00
2597
CN ACQUISITION STATION
2
Cleared 510(K)
K
00
2590
CEDARA CARDIOLOGY VIEWER, CARDIOLOGY ARCHIVE VIEWER, CARDIOLOGY CD VIEWER
2
Cleared 510(K)
K
00
2424
3D ANGIOGRAPHIC IMAGING SYSTEM, MODEL XIDF-100A
2
Cleared 510(K)
K
00
2519
VITREA 2, VERSION 2.1
2
Cleared 510(K)
K
00
2936
MODIFICATION TO IDS5 IMAGE DISPLAY SYSTEM
2
Cleared 510(K)
K
00
2144
MEDLINK DIAGNOSTIC OFFLINE WORKSTATION
2
Cleared 510(K)
K
00
2039
ECAT PET SCANNER, MODELS ECAT EXACT AND ECAT EXACT HR+ AND ECAT ART
2
Cleared 510(K)
K
00
2100
XIMX SYSTEM
2
Cleared 510(K)
K
00
1753
MEDIS 5MP2 DUAL-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1748
MEDIS 5MP2 QUAD-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1750
MEDIS 5MP1H QUAD-HEAD MEDICIAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1752
MEDIS 55MP1H SINGLE-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1754
MEDIS 5MP1H DUAL-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1751
MEDIS 2MP2 QUAD-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1747
MEDIS 2MP2 DUAL-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
00
1596
LIFERX
2
Cleared 510(K)
K
00
1012
DIGITAL INTEGRATION SYSTEM, DIS2000
2
Cleared 510(K)
K
00
0770
PROVIEW MEDICAL IMAGE DISPLAY MODULE
2
Cleared 510(K)
K
00
0630
MODELS PRIAM (FAMILY OF DEVICES) DIGITAL IMAGING SYSTEM
2
Cleared 510(K)
K
00
1140
IDS5 IMAGE DISPLAY SYSTEM
2
Cleared 510(K)
K
00
0395
EINSTEIN PROCESSING AND REVIEW WORKSTATION
2
Cleared 510(K)
K
00
0380
FOTOMASTER
2
Cleared 510(K)
K
00
0557
MEDVIZER PACS, MODEL RELEASE 2000
2
Cleared 510(K)
K
00
0443
REMOTE FETAL MEDICINE ULTRASOUND SYSTEM
2
Cleared 510(K)
K
00
0448
PACSSTATION
2
Cleared 510(K)
K
00
0474
VIEW NT
2
Cleared 510(K)
K
00
0293
BARCO MGD 221 2 MEGAPIXEL DIAGNOSTIC DISPLAY
2
Cleared 510(K)
K
00
0292
BARCO MWD 321 PLUS MEDICAL WORKSTATION DISPLAY
2
Cleared 510(K)
K
00
0294
MFCD 120
2
Cleared 510(K)
K
00
0291
MFCD 118
2
Cleared 510(K)
K
00
0014
BARCOMED 5MP1H
2
Cleared 510(K)
K
00
0016
BARCOMED 5MP2
2
Cleared 510(K)
K
99
4270
INSTATRAK 3000 SYSTEM WITH FLUOROTRAK MODULE, MODEL IT3000
2
Cleared 510(K)
K
99
3946
PEGASYS ULTRA
2
Cleared 510(K)
K
99
4228
REMOTEIMAGE SYSTEM
2
Cleared 510(K)
K
99
4054
ISSA PHAROS
2
Cleared 510(K)
K
00
0015
BARCOMED 2MP2
2
Cleared 510(K)
K
99
4210
INTURIS SUITE
2
Cleared 510(K)
K
99
3750
PROSOLV ECHOVIEWER, PROSOLV ECHOVIEWER SE, PROSOLV ECHOANALYZER, PROSOLV ECHOSERV, PROSOLV ECHO
2
Cleared 510(K)
K
99
3802
SHARPVIEW IMAGE ENHANCEMENT SYSTEM
2
Cleared 510(K)
K
99
3338
INTEGRATED DIGITAL MEDICAL RECORD (IDMR)
2
Cleared 510(K)
K
99
3283
OSCAR NET/CD, MODEL M1.82 600 . O/A/B/C
2
Cleared 510(K)
K
99
3761
CARDIOVASCULAR MEASUREMENT SYSTEM - VIEW
2
Cleared 510(K)
K
99
3227
PHILIPS INTURIS DICOM RECORDER
2
Cleared 510(K)
K
99
3532
DDS, DS3000, RS3000, CS5000, OT3000, IS3000, RS5000, CD3000, US3000, (AMONGST OTHER NAMES)
2
Cleared 510(K)
K
99
3530
SYSTEM 2100
2
Cleared 510(K)
K
99
2925
AX WORKSTATION DR-VIEWER SOFTWARE OPTION
2
Cleared 510(K)
K
99
2886
POWERVIEW ULTRASOUND WORKSTATION, UIDM-400A
2
Cleared 510(K)
K
99
2654
PLUG 'N VIEW 3D, VERSION 1.0
2
Cleared 510(K)
K
99
2666
VIDEO PLUS SYSTEM, SERIES 95000
2
Cleared 510(K)
K
99
2354
SNT IMAGE ANALYSIS SYSTEM
2
Cleared 510(K)
K
99
2575
CARDIOVASCULAR WORKSTATION, MODEL CWS 5000/CWS 3000
2
Cleared 510(K)
K
99
0241
ACCUIMAGE, ACCUVIEW DIAGNOSTIC IMAGING, WORKSTATION W/ACCUSCORE, ACCUANALYZE, ACCUSCOPE, ACCUSHADE, ACCUVRT, AND ACCUMIP
2
Cleared 510(K)
K
99
2306
SAMSUNG RAYPAX DISPLAY WORKSTATION
2
Cleared 510(K)
K
99
2112
SAMSUNG RAYPAX FILM DIGITIZER
2
Cleared 510(K)
K
99
2073
AX WORKSTATION
2
Cleared 510(K)
K
99
2259
ECHOCARDIOGRAPHY SYSTEM SERIES 95000
2
Cleared 510(K)
K
99
1738
DIGITAL VIDEO RECORDING SYSTEM
2
Cleared 510(K)
K
99
1629
GE VIEW APPLICATIONS (CONSISTING OF GE VIEWING STATION AND GE EXTENDED VIEWING STATION) VERSION 1.2C
2
Cleared 510(K)
K
99
1468
IMMERGE IMAGE CORRELATION
2
Cleared 510(K)
K
99
1626
WEBRAD COMPUTED RADIOGRAPHY QUALITY ASSURANCE WORKSTATION
2
Cleared 510(K)
K
99
1257
FUJI WAVELET COMPRESSION OR FFCOMP IRREVERSIBLE COMPRESSION
2
Cleared 510(K)
K
99
1643
IDS4 V3.2 IMAGE DISPLAY SYSTEM
2
Cleared 510(K)
K
99
1578
SMARTSPOT 2000
2
Cleared 510(K)
K
99
0455
PHILIPS EASY VISION FAMILY WORKSTATION LEGS OPTION
2
Cleared 510(K)
K
99
0442
ADVANCED DIAGNOSTIC VIEWER (AOX), MODEL VITRED 1.3
2
Cleared 510(K)
K
99
0919
STRAIGHT ASPIRATOR, 90 DEGREE ASPIRATOR,45 DEGREE ASPIRATOR,7 FRENCH ASPIRATOR,EXTENDED STRAIGHT ASPIRATOR,13.9 CM STRAG
2
Cleared 510(K)
K
99
0759
VIEW COM
2
Cleared 510(K)
K
99
0052
TEL-ECHO SYSTEM
2
Cleared 510(K)
K
98
4215
WELCH ALLYN FRONT-LINE DOC
2
Cleared 510(K)
K
98
3815
PACSCACHE
2
Cleared 510(K)
K
98
3529
INSTATRAK 3000
2
Cleared 510(K)
K
98
2535
INSIGHT DIAGNOSTIC IMAGING WORKSTATION
2
Cleared 510(K)
K
98
3401
FRAMEWAVE WEB
2
Cleared 510(K)
K
98
3392
DATA RAY CORPORATION DR11021 MEDICAL IMAGING MONITOR
2
Cleared 510(K)
K
98
3256
ADVANTAGE WINDOWS (AW) FUSION
2
Cleared 510(K)
K
98
3821
PHILIPS INTURIS CARDIO IMAGE VIEWING PACKAGE
2
Cleared 510(K)
K
98
4023
MAXVIEW DIAGNOSTIC WORKSTATION
2
Cleared 510(K)
K
98
2976
ULTRASOUND WORKSTATION, UIWS-300A
2
Cleared 510(K)
K
98
3111
XRAY VISION
2
Cleared 510(K)
K
98
2994
SKULL BASE INSTATRAK SYSTEM
2
Cleared 510(K)
K
98
2769
MITRA IMAGING INC. EXHIBIT
2
Cleared 510(K)
K
98
2862
RADWORKS MEDICAL IMAGING SOFTWARE WITH QUALITY CONTROL MODULE
2
Cleared 510(K)
K
98
2820
BARCO MEDIS 5MP 5 MEGAPIXEL MEDICAL DIAGNOSTIC DISPLAY SYSTEM
2
Cleared 510(K)
K
98
2690
BARCO MEDICAL DISPLAY CONFORMITY AND CONSISTENCY SOFTWARE
2
Cleared 510(K)
K
98
2563
ULTRAPRO MODEL 98
2
Cleared 510(K)
K
98
2422
EAGLESOFT CHAIRSIDE
2
Cleared 510(K)
K
98
3088
INSTACINE D-2000
2
Cleared 510(K)
K
98
2146
PICTOOLS MEDICAL TOOL KIT MODEL 1.0
2
Cleared 510(K)
K
98
2120
DIGITAL IMAGING SYSTEM, MODELS DIGITREX-1000 AND DIGITREX-2000 (DIGITREX-X000 FAMILY)
2
Cleared 510(K)
K
98
1998
PEDIATRIC INSTATRAK SYSTEM
2
Cleared 510(K)
K
98
0648
PRO VISION
2
Cleared 510(K)
K
98
1217
PLATINUM READING, REVIEW & ANALYSIS WORKSTATION
2
Cleared 510(K)
K
98
0234
THE NETWORK SYSTEM
2
Cleared 510(K)
K
98
0970
IIRAD DIRECTRAY OPERATOR CONSOLE
2
Cleared 510(K)
K
98
0168
COMPUTED RADIOGRAPHY QUALITY ASSURANCE SOFTWARE
2
Cleared 510(K)
K
98
0118
KODAK DIGITAL SCIENCE ONCOLOGY IMAGE MANAGER
2
Cleared 510(K)
K
97
4755
DYNA VUE 3-D IMAGING PRODUCT
2
Cleared 510(K)
K
97
4504
EPS
2
Cleared 510(K)
K
98
0060
ECHOLINK
2
Cleared 510(K)
K
97
4474
PEGASYS INTOUCH
2
Cleared 510(K)
K
97
1965
PHILIPS EASYVISION
2
Cleared 510(K)
K
97
4134
X-SIGHT DIGITAL IMAGING SYSTEM
2
Cleared 510(K)
K
97
4207
PHILIPS EASYVISION WORKSTATION
2
Cleared 510(K)
K
97
4086
KODAK DIGITAL SCIENCE CARDIAC VIEWER
2
Cleared 510(K)
K
97
3983
PHILLIPS EASY VISION FAMILY WORKSTATION OPTION ENDO 3D
2
Cleared 510(K)
K
97
3835
PHILIPS EASYVISION WORKSTATION
2
Cleared 510(K)
K
97
3653
SEEMOR - DISPLAY & PROCESSING PROGRAM EXECUTING ON PERSONAL COMPUTER SYSTEM
2
Cleared 510(K)
K
97
3148
MACOM
2
Cleared 510(K)
K
97
2215
MEDIMAGE
2
Cleared 510(K)
K
97
3065
REALVIEW TELEMEDICINE SYSTEM
2
Cleared 510(K)
K
97
3010
REALTIME 3D DIAGNOSTIC WORKSTATION
2
Cleared 510(K)
K
97
3081
DIGITIZER DIRECTOR: IMAGE COMPRESSION MODULE (HO4059-REV 2.0)
2
Cleared 510(K)
K
97
2933
VOX/BASE FOR WINDOWS
2
Cleared 510(K)
K
97
2886
MIRAGE
2
Cleared 510(K)
K
97
2520
OPTIVIEW
2
Cleared 510(K)
K
97
2256
FCR FUJI COMPUTED RADIOGRAPHY DMS CRT IMAGE CONSOLE HI-C654 (FOR NETWORKS)
2
Cleared 510(K)
K
97
2103
PHILIPS EASYVISION
2
Cleared 510(K)
K
97
1973
KODAK DIGITAL SCIENCE PRO-MEDICAL THERMAL PRINTER
2
Cleared 510(K)
K
97
1776
ECHOVACS
2
Cleared 510(K)
K
96
5179
INSIGHT DIAGNOSTIC IMAGING WORKSTATION NIT-DU0-ZOO
2
Cleared 510(K)
K
97
1368
IDS4 IMAGE DISPLAY SYSTEM SERIES
2
Cleared 510(K)
K
97
1714
NDC DENTAL SYSTEM, VERSION 1.5 X-RAY AND VIDEO
2
Cleared 510(K)
K
97
1290
STRATASYS FDM MEDMODELER SYSTEM
2
Cleared 510(K)
K
97
0964
MAESTRO DIGITAL IMAGE AND PATIENT RECORD STORAGE SYSTEM
2
Cleared 510(K)
K
97
0813
DIMS (DIGITAL IMAGING AND MEDICAL SYSTEM) CL1-5110/5111
2
Cleared 510(K)
K
97
0623
IMMERGE IMAGE CORRELATION
2
Cleared 510(K)
K
97
0617
CT-MODELLER SYSTEM
2
Cleared 510(K)
K
97
0451
DOWNSCAN 120
2
Cleared 510(K)
K
97
0534
PICTURE ARCHIVING & COMMUNICATIONS DEVICE
2
Cleared 510(K)
K
97
0450
UPSCAN 120
2
Cleared 510(K)
K
97
0349
FUJI MEDICAL LASER IMAGER MF PRINT SERVER MF-PS667
2
Cleared 510(K)
K
97
0402
DOCTORS REVIEW SYSTEM
2
Cleared 510(K)
K
96
2010
EPI-SCOPE OPTION FOR Q SERIES CT SYSTEMS
2
Cleared 510(K)
K
96
4327
IPU RX-2
2
Cleared 510(K)
K
96
2153
DIGITAL IMAGE ANALYSIS SYSTEM
2
Cleared 510(K)
K
96
3980
PHILIPS EASYVISION
2
Cleared 510(K)
K
96
4124
PHILIPS COMPUTED RADIOGRAPHY
2
Cleared 510(K)
K
96
3859
QLVA PLUS
2
Cleared 510(K)
K
96
3697
ADVANCED DIAGNOSTIC VIEWER (ADV)
2
Cleared 510(K)
K
96
3610
AKI COMPACS DATA COMPRESION MODULE FOR DIAGNOSTIC IMAGES
2
Cleared 510(K)
K
96
1740
KODAK DIGITAL SCIENCE MEDICAL PRINTER INTERFACE UNIT
2
Cleared 510(K)
K
96
1739
KODAK DIGITAL SCIENCE MEDICAL MODALITY ACQUISITION UNIT
2
Cleared 510(K)
K
96
3037
PATRIOT
2
Cleared 510(K)
K
96
2589
AURORA DIAGNOSTIC WORKSTATION
2
Cleared 510(K)
K
96
2260
REAL-TIME VIDEO CONTRAST ENHANCER
2
Cleared 510(K)
K
96
1983
TRS 2000 TELERADIOLOGY SYSTEM
2
Cleared 510(K)
K
96
1871
FLOUROSPOT T.O.P.
2
Cleared 510(K)
K
96
1637
PICKER MR WORKSTATIONS (VISTAR,MONTAGE AND ONCALL)
2
Cleared 510(K)
K
96
1403
LIFE IMAGING SYSTEMS LIS 6000 A
2
Cleared 510(K)
K
96
0265
ADVANTAGE WINDOWS WITH FUNCTOOL OPTION
2
Cleared 510(K)
K
96
1307
SMART SPOT
2
Cleared 510(K)
K
95
3911
PHILIPS EASYVISION
2
Cleared 510(K)
K
95
5457
DIGISCAN 2 PLUS
2
Cleared 510(K)
K
95
5092
ACCURAD IMAGE MANAGEMENT SYSTEM, AUTORAD, REGUSTRATION STATION, ARCHIVE SERVER, PRINT SPOOLER, ANALOG & DIGITAL ACQUIRE
2
Cleared 510(K)
K
96
0946
ECHONET
2
Cleared 510(K)
K
96
0665
ECHO-COM FOR MS-WINDOWS VERSION 2.0
2
Cleared 510(K)
K
96
0613
GE ADVANTAGE WINDOWS REVIEW WORKSTATION
2
Cleared 510(K)
K
96
0071
IMAGEFUSION
2
Cleared 510(K)
K
96
0330
INSTATRAK
2
Cleared 510(K)
K
96
0043
KODAK CARDIOLOGY DIGITAL ARCHIVE & REVIEW SYSTEM
2
Cleared 510(K)
K
95
4159
DIGITAL IMAGING SYSTEM
2
Cleared 510(K)
K
95
3616
PREVIEW SURGERY PLANNING SOFTWARE
2
Cleared 510(K)
K
95
4678
PRO VISION
2
Cleared 510(K)
K
95
4589
CLARK TUT IMAGE PROCESSING SYSTEM
2
Cleared 510(K)
K
95
5185
GE ADVANTAGE DICOM CR REPROCESSING STATION
2
Cleared 510(K)
K
95
4860
ECHONET
2
Cleared 510(K)
K
94
4612
ACUSTAR I ADVANCED SURGICAL NAVIGATION SYSTEM
2
Cleared 510(K)
K
95
4222
VIDEO ENHANCEMENT UNIT
2
Cleared 510(K)
K
95
4211
CRISPICS
2
Cleared 510(K)
K
95
3259
VOXELVIEW
2
Cleared 510(K)
K
95
4668
HP ECHO IMAGE MANAGEMENT SYSTEM
2
Cleared 510(K)
K
95
3095
PHILIPS EASYVISION
2
Cleared 510(K)
K
95
1262
OPERATING ARM SYSTEM (OAS)
2
Cleared 510(K)
K
95
4055
HDX DIGITAL IMAGING SYSTEM
2
Cleared 510(K)
K
95
2862
FUJI COMPUTED RADIOGRAPHY SYSTEM FCR9501ES.FCR
2
Cleared 510(K)
K
95
2778
CHESHIRE
2
Cleared 510(K)
K
95
2313
VARIS IMAGES, INCLUDING XIMATRON DIGITAL IMAGING OPTION
2
Cleared 510(K)
K
95
3164
ALALYSIS PACKAGE FOR DENTAL APPLICATIONS FOR XPEED, XPRESS, XVISION
2
Cleared 510(K)
K
94
5807
HOMEVUE WOUND MONITORING SYSTEM
2
Cleared 510(K)
K
94
5188
CEMAX VIPSTATION AND/OR SOFTWARE
2
Cleared 510(K)
K
94
1566
COMPUSPEAK
2
Cleared 510(K)
K
94
5582
WITT BIOMEDICAL IMAGE III
2
Cleared 510(K)
K
94
2504
INSTASPOT
2
Cleared 510(K)
K
94
5428
SCRIBE(TM) DIAGNOSTIC IMAGING WORKSTATION
2
Cleared 510(K)
K
94
6117
MEDICAL IMAGE MANAGEMENT SYSTEM (MIM)
2
Cleared 510(K)
K
94
5389
IVR MASTER
2
Cleared 510(K)
K
92
5963
IMAGE TRANSPORT SERIES II
2
Cleared 510(K)
K
94
5388
DFS-700
2
Cleared 510(K)
K
93
4572
UNITONE
2
Cleared 510(K)
K
94
0664
PAPER FILM
2
Cleared 510(K)
K
94
1093
SMARTPACS FILMLESS READING AND IMAGE DISTRIBUTION SYSTEM AND CONSULTATION STATION
2
Cleared 510(K)
K
93
6179
WINRAD TELERADIOLOGY SYSTEM
2
Cleared 510(K)
K
94
1933
ISG MEDICAL IMAGING FAMILY OF WORKSTATIONS (MIFW)
2
Cleared 510(K)
K
91
1783
ALLEGRO VIEWING WAND
2
Cleared 510(K)
K
93
2564
RADSTAT
2
Cleared 510(K)
K
93
5694
SIENET DIAGNOSTIC REPORTING CONSOLE VA02 UPGRADE
2
Cleared 510(K)
K
93
2371
CEMAX CLINICALVIEW(TM) STATION AND/OR SOFTWARE
2
Cleared 510(K)
K
93
2372
CEMAX VIPSTATION(TM) AND/OR SOFTWARE
2
Cleared 510(K)
K
93
3209
VISIONTOOL
2
Cleared 510(K)
K
93
1376
GAMMACON IMAGE TRANSLATION SYSTEM
2
Cleared 510(K)
K
92
5664
SERIES V-SCAN RADIOGRAPHIC FILM SCANNER
2
Cleared 510(K)
K
93
0527
DENTAL LINK
2
Cleared 510(K)
K
92
0851
MACVIEW
2
Cleared 510(K)
K
92
4630
SURGICAD(TM) VIEW(TM)
2
Cleared 510(K)
K
92
4366
PERSONAL DISPLAY SYSTEM
2
Cleared 510(K)
K
92
5793
TELESHARE 910
2
Cleared 510(K)
K
92
2267
PHOTOPHONE(R) MULTI VIEW(TM)
2
Cleared 510(K)
K
92
5465
TELERADIOLOGY DEVICE & COMPONENT OF PACS COMPONENT
2
Cleared 510(K)
K
92
4310
PRESTILIX 1694 D IMAGE INTENSIFIED FLUOROSCCOPIC
2
Cleared 510(K)
K
92
3042
DU PONT LINX HD-25 LASR IMAGER
2
Cleared 510(K)
K
92
3913
NOISE REDUCTION UNIT W/ LAST IMAGE HOLD
2
Cleared 510(K)
K
92
0319
SIENET IMAGE DISPLAY WORKSTATIONS, IMAGE ACQUISITI
2
Cleared 510(K)
K
92
3270
KODAK EKTASCAN IMAGELINK QUALITY CONTROL WORKSTATI
2
Cleared 510(K)
K
92
1484
MEDVISION
2
Cleared 510(K)
K
92
2310
VORTECH'S PERSONAL DISPLAY SYSTEM
2
Cleared 510(K)
K
91
5342
UD 2000 VIDEO OPTION
2
Cleared 510(K)
K
92
0950
PHILIPS EASYVISION
2
Cleared 510(K)
K
92
0309
SIENET DIAGNOSTIC REPORTING CONSOLE
2
Cleared 510(K)
K
91
4366
MEDRAD PATHFINDER HR ROADMAPPING SYSTEM
2
Cleared 510(K)
K
91
5305
OPTION U1 FOR THE DPS-PLUS SYSTEM
2
Cleared 510(K)
K
91
5542
QCA PLUS
2
Cleared 510(K)
K
91
5237
PHILIPS PCR-ACE SYSTEM
2
Cleared 510(K)
K
91
3755
STATVIEW
2
Cleared 510(K)
K
91
3264
HYDRAVIEW 1000 DIGITAL IMAGE PROCESS/STOR DEVICE
2
Cleared 510(K)
K
91
3754
CARDIO 500
2
Cleared 510(K)
K
91
2829
CARDIOTRACE CARDIAC EVALUATION SYSTEMS
2
Cleared 510(K)
K
91
1752
ICON TELERADIOLOGY SYSTEM
2
Cleared 510(K)
K
90
4519
AGFA DIAGNOSTIC CENTER (ADC)
2
Cleared 510(K)
K
91
0437
FUJI COMPUTED RADIOGRAPHY SYSTEM FCR 7501
2
Cleared 510(K)
K
90
5132
SHIMADZU IMAGE PROCESSOR DFS-500
2
Cleared 510(K)
K
90
5801
CEMAX SPARCSTATION IMAGING SOFTWARE AND WORKSTATIO
2
Cleared 510(K)
K
90
5222
CEDARS-SINAI QUANTITATIVE TI-201 ANALYSIS CTQ 2.0
2
Cleared 510(K)
K
90
2428
INTEGRATED DIAGNOSTIC SYSTEM W/ADD'L OPTIONS
2
Cleared 510(K)
K
90
4590
KODAK EKTASCAN LASER PRINTER, MODEL 100 XLP
2
Cleared 510(K)
K
90
1422
SCIVIEW SYSTEM, MODEL SC1250 AND PIXIE IMAGING SOF
2
Cleared 510(K)
K
90
2648
PINNACLE IMAGE PROCESSING SYSTEM
2
Cleared 510(K)
K
90
3196
IMAGE INTENSIFIED FLUOROSCOPIC X-RAY SYSTEM
2
Cleared 510(K)
K
90
1679
RESUBMITTED ISG 3DMV WORKSTATION
2
Cleared 510(K)
K
90
0851
DIGITAL IMAGE ENHANCEMENT SYSTEM
2
Cleared 510(K)
K
90
0697
CEDARS-SINAI QUANTITATIVE THALLIUM-201 ANALYSIS
2
Cleared 510(K)
K
90
1158
LITEBOX DIAGNOSTIC REVIEW WORKSTATION
2
Cleared 510(K)
K
89
7000
IMAGEMASTER-101(TM)
2
Cleared 510(K)
K
90
0586
MEDRAD FLUOROVISION HR 2000, HIGH RESOLUTION IMAGE
2
Cleared 510(K)
K
89
6050
FUJI COMPUTED RADIOGRAPHY SYSTEM FCR AC-1 (FCR)
2
Cleared 510(K)
K
89
2711
QUANTIM 2000I DIGITAL IMAGE ANALYSIS SYSTEM
2
Cleared 510(K)
K
89
4402
HIPGRAPHICS SYSTEM ONE W/ORTHOTOOL
2
Cleared 510(K)
K
89
5320
FLUOROVISION HR 2000 HIGH RESOLUTION IMAGE ENHANCE
2
Cleared 510(K)
K
89
2397
MODIFIED CEDARS-SINAI QUANTI THALLIUM-201 ANALYSIS
2
Cleared 510(K)
K
89
1692
MIP MR
2
Cleared 510(K)
K
89
1689
MIPRON/UMIPRON
2
Cleared 510(K)
K
89
1695
VIEW 1000
2
Cleared 510(K)
K
89
2712
MIP/CT IMAGE PROCESSING WORKSTATION
2
Cleared 510(K)
K
89
3585
14 COLOR VIDEO DISPLAY 211-260-010
2
Cleared 510(K)
K
89
3521
IMLOGIX 1000 IMAGE DISPLAY SYSTEM
2
Cleared 510(K)
K
89
2869
ANGIOTEC ZX DIGITAL IMAGE PROCESSOR
2
Cleared 510(K)
K
88
4621
DIGISCAN
2
Cleared 510(K)
K
89
0397
REDI-VU MODEL RV-386
2
Cleared 510(K)
K
88
4995
SIEMENS PACS/1-B (OPTICAL DISK OPTION)
2
Cleared 510(K)
K
88
5318
DIGITRON 3, LV ANALYSIS PROTCOL
2
Cleared 510(K)
K
88
2933
DACA-100
2
Cleared 510(K)
K
88
3476
VOXEL FLINGER(TM) 3-D IMAGING SYSTEM
2
Cleared 510(K)
K
88
3604
MEDRAD IMAGE MANAGEMENT SYSTEM (MIMS)
2
Cleared 510(K)
K
88
2271
CTQ - CEDARS-SINAI QUANTITATIVE THALLIUM-201 ANALY
2
Cleared 510(K)
K
88
1481
DIGITRON STENOSIS PROTOCOL
2
Cleared 510(K)
K
88
1993
PXI (PERSONAL X-RAY IMAGER) 512
2
Cleared 510(K)
K
88
2205
VIEWPOINT
2
Cleared 510(K)
K
88
1017
DPS-33,000 WITH CENTOR OPTION
2
Cleared 510(K)
K
88
0169
CEMAX 5000 MULTIDIMENSIONAL IMAGING WORKSTATION
2
Cleared 510(K)
K
87
4865
DAMON D.E.T.E.C.T IMAGE ENHANCER
2
Cleared 510(K)
K
87
3646
DIGIVIEWER
2
Cleared 510(K)
K
87
2455
DPS-4100 PLUS DIGITAL RADIOGRAPHY SYSTEM
2
Cleared 510(K)
K
87
0821
POLYTRON MODELS 1001, 1002 AND 1004
2
Cleared 510(K)
K
86
4854
VIEW(TM) IMAGE PROCESSING AND VIEWING STATION
2
Cleared 510(K)
K
86
4519
PHILIPS COMPUTED RADIOGRAPHY SYSTEM (PCR)
2
Cleared 510(K)
K
86
4739
KODAK EKTASCAN IMAGE TRANSMISSION SYSTEM P1
2
Cleared 510(K)
K
86
4927
KODAK EKTASCAN IMAGE TRANS SYS T1/R1 SOFTWARE,1.10
2
Cleared 510(K)
K
86
3132
DIGITAL FLUORICON CARDIAC/VASCULAR QUANTITATIVE
2
Cleared 510(K)
K
86
2294
THE IMAGE/R
2
Cleared 510(K)
K
86
1514
VNA OPTICAL CORRELATOR
2
Cleared 510(K)
K
86
2309
PC-DISPLAY
2
Cleared 510(K)
K
86
1852
CSI/MPR OR CSI/MPR PLUS
2
Cleared 510(K)
K
86
1429
DIGITRON 3V,3VA,3VAC,3 HIGH RESOLUTION UPGRADE
2
Cleared 510(K)
K
86
1279
FLUORO PLUS
2
Cleared 510(K)
K
85
4810
FC-1000 FLUOROSCOPIC IMAGING COMPUTER
2
Cleared 510(K)
K
85
5002
KODAK EKTASCAN IMAGE TRANSMISSION SYSTEM
2
Cleared 510(K)
K
85
2284
DIGIRAD SYSTEM 1 AND THE REUSUABLE IMAGE MEDIA
2
Cleared 510(K)
K
85
0080
DIGITAL IMAGE PROCESSOR FP-2C
2
Cleared 510(K)
K
84
3708
ADAC DPS-4070 DIGITAL RADIOGRAPHY SYS
2
Cleared 510(K)
K
84
4298
ADAC MODEL DPS-3300M DIGITAL PROCESSING SYSTEM
2
Cleared 510(K)
K
84
4037
DIGITAL FLUOROGRAPHIC IMAGING SYSTEM DIGIFORMER
2
Cleared 510(K)
K
84
4317
DMI CONSOLE
2
Cleared 510(K)
K
84
4783
DPS-3300 MICRO NUCLEAR MEDICINE IMAGING COMPUTER
2
Cleared 510(K)
K
84
4784
DPS-33000 NUCLEAR MEDICINE IMAGING COMPUTER
2
Cleared 510(K)
K
83
2895
VISION TWO, ONE/10 ONE/20 &24
2
Cleared 510(K)
LMA
Digitizer, Image, Radiological
2
Product Code
LMB
Device, Digital Image Storage, Radiological
1
Product Code
LMC
Camera, Multi Format, Radiological
2
Product Code
LMD
System, Digital Image Communications, Radiological
1
Product Code
LNH
System, Nuclear Magnetic Resonance Imaging
2
Product Code
LNI
System, Nuclear Magnetic Resonance Spectroscopic
2
Product Code
LQA
Media, Reusable Image
1
Product Code
MOS
Coil, Magnetic Resonance, Specialty
2
Product Code
MQB
Solid State X-Ray Imager (Flat Panel/Digital Imager)
2
Product Code
MUA
Bone Sonometer
2
Product Code
MUE
Full Field Digital, System, X-Ray, Mammographic
2
Product Code
MUI
Media, Coupling, Ultrasound
2
Product Code
MWP
Cabinet, X-Ray System
2
Product Code
MYN
Analyzer, Medical Image
2
Product Code
NCS
System, Imaging, Holography, Acoustic
2
Product Code
NWE
Colon Computed Tomography System, Computer Aided Detection
2
Product Code
OAS
X-Ray, Tomography, Computed, Dental
2
Product Code
OEB
Lung Computed Tomography System, Computer-Aided Detection
2
Product Code
OII
Arthrogram Tray
2
Product Code
OIJ
Biopsy Needle Guide Kit
2
Product Code
OIK
Radiology Dental Tray
2
Product Code
OIL
Discography Kit
2
Product Code
OIM
Mri Disposable Kit
2
Product Code
OIO
Radiographic Contrast Tray
2
Product Code
OIP
Radiology-Diagnostic Kit
2
Product Code
OMJ
Chest X-Ray Computer Aided Detection
2
Product Code
OQQ
Diagnostic Ultrasonic Transducer, Robotic
2
Product Code
OUO
Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
2
Product Code
OWB
Interventional Fluoroscopic X-Ray System
2
Product Code
OXO
Image-Intensified Fluoroscopic X-Ray System, Mobile
2
Product Code
PCS
Liver Iron Concentration Imaging Companion Diagnostic For Deferasirox
2
Product Code
PGY
Display, Diagnostic Radiology
2
Product Code
POK
Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer
2
Product Code
QAS
Radiological Computer-Assisted Triage And Notification Software
2
Product Code
QBS
Radiological Computer Assisted Detection/Diagnosis Software For Fracture
2
Product Code
QDQ
Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For Cancer
2
Product Code
QFM
Radiological Computer-Assisted Prioritization Software For Lesions
2
Product Code
QHA
X-Ray Angiographic Imaging Based Coronary Vascular Simulation Software Device
2
Product Code
QHX
Fluoroscopic X-Ray Image Intensifier
1
Product Code
QHY
Solid State Fluoroscopic X-Ray Imager
2
Product Code
QIH
Automated Radiological Image Processing Software
2
Product Code
QJU
Image Acquisition And/Or Optimization Guided By Artificial Intelligence
2
Product Code
QKB
Radiological Image Processing Software For Radiation Therapy
2
Product Code
RCC
C-Arm Fluoroscopic X-Ray System
2
Product Code
QTZ
Radiological Image Processing Software For Ablation Therapy Planning And Evaluation
2
Product Code
QXL
Cabinet, Emission Computed Tomography System
2
Product Code
SFV
X-Ray, Computed Tomography, Cone-Beam
2
Product Code
Subpart C—Obstetrical and Gynecological Monitoring Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Subpart G—Miscellaneous Devices
CFR Sub-Part
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 3 April 2026 at 11:13 pm
RA
/
subpart-b—diagnostic-devices
/
LLZ
/
K042292
View Source
ISITE PACS
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K042292
510(k) Type
Traditional
Applicant
Stentor, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
9/8/2004
Days to Decision
15 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
Miscellaneous
Subpart B—Diagnostic Devices
EAG
Cephalometer
EAH
Cone, Radiographic, Lead-Lined
EAP
Unit, X-Ray, Intraoral
EHB
Collimator, X-Ray
EHD
Unit, X-Ray, Extraoral With Timer
MUH
System, X-Ray, Extraoral Source, Digital
EAM
Screen, Intensifying, Radiographic
EGT
Controller, Temperature, Radiographic
EGW
Dryer, Film, Radiographic
EGY
Processor, Radiographic-Film, Automatic, Dental
HBK
Chair, Pneumoencephalographic
ITX
Transducer, Ultrasonic, Diagnostic
ITY
Assembly, Tube Housing, X-Ray, Diagnostic
IWN
Cassette, Measurement, Ardran-Crooks
IWY
Holder, Head, Radiographic
IWZ
Film, Radiographic
IXA
Cassette, Radiographic Film
IXC
Illuminator, Radiographic-Film
IXD
Source, Calibration, Sealed, Nuclear
IXF
Test-Pattern, Radiographic
IXG
Phantom, Anthropomorphic, Radiographic
IXH
Camera, Focal Spot, Radiographic
IXJ
Grid, Radiographic
IXK
System, Imaging, X-Ray, Electrostatic
IXL
Device, Spot-Film
IXO
Synchronizer, Ecg / Respirator, Radiographic
IXQ
Table, Radiographic, Stationary Top
IXR
Table, Radiographic, Tilting
IXW
Processor, Radiographic-Film, Automatic
IXX
Processor, Cine Film
IXY
Holder, Radiographic Cassette, Wall-Mounted
IYB
Tube Mount, X-Ray, Diagnostic
IYN
System, Imaging, Pulsed Doppler, Ultrasonic
IYO
System, Imaging, Pulsed Echo, Ultrasonic
IYP
Phantom, Anthropomorphic, Nuclear
IYQ
Phantom, Flood Source, Nuclear
IYT
System, Rebreathing, Radionuclide
IYW
Scanner, Rectilinear, Nuclear
IYX
Camera, Scintillation (Gamma)
IYY
Synchronizer, Electrocardiograph, Nuclear
IYZ
Bed, Scanning, Nuclear
IZC
Camera, Positron
IZD
Probe, Uptake, Nuclear
IZF
System, X-Ray, Tomographic
IZG
System, X-Ray, Photofluorographic
IZH
System, X-Ray, Mammographic
IZI
System, X-Ray, Angiographic
IZJ
Camera, X-Ray, Fluorographic, Cine Or Spot
IZL
System, X-Ray, Mobile
IZO
Generator, High-Voltage, X-Ray, Diagnostic
IZP
Programmer, Changer, Film/Cassette, Radiographic
IZS
Aperture, Radiographic
IZT
Cone, Radiographic
IZW
Collimator, Automatic, Radiographic
IZX
Collimator, Manual, Radiographic
IZZ
Table, Radiographic, Non-Tilting, Powered
JAA
System, X-Ray, Fluoroscopic, Image-Intensified
JAB
System, X-Ray, Fluoroscopic, Non-Image-Intensified
JAC
System, X-Ray, Film Marking, Radiographic
JAF
Monitor, Ultrasonic, Nonfetal
JAG
Illuminator, Radiographic-Film, Explosion-Proof
JAK
System, X-Ray, Tomography, Computed
JAM
Scanner, Whole Body, Nuclear
JAN
Counter, Whole Body, Nuclear
JAO
Scanner, Fluorescent
JAR
Phantom, Test-Pattern, Radionuclide
JWM
System, Tomographic, Nuclear
KGI
Densitometer, Bone
KPR
System, X-Ray, Stationary
KPS
System, Tomography, Computed, Emission
KPT
Calibrator, Dose, Radionuclide
KPW
Device, Beam Limiting, X-Ray, Diagnostic
KPX
Changer, Radiographic Film/Cassette
KXH
Cradle, Patient, Radiologic
KXJ
Table, Radiologic
LEK
Transilluminator (Diaphanoscope)
LHO
Instrument, Quality-Assurance, Radiologic
LLZ
System, Image Processing, Radiological
K
25
3784
3DICOM MD Cloud
K
25
3639
View
K
25
3008
maiLink
K
25
1883
MIM – LesionID Pro
K
25
1880
Archy Dental Imaging
K
25
3495
syngo.MR Applications (VB80)
K
25
1410
VXvue
K
25
1532
Acorn 3D Software (AC-SEG-4009); Acorn 3DP Model (AC-101-XX)
K
25
2547
TheraSphere 360™ Y-90 Management Platform
K
25
1030
Sirona Advanced Imaging Suite
K
25
2476
Viewer (5.4); Elements Viewer; Mixed Reality Viewer; Smart Layout; Elements Viewer Smart Layout
K
25
2199
AGFA HealthCare Enterprise Imaging
K
25
1363
ProKnow DS
K
25
0039
HPACS
K
25
1215
Philips IntelliSpace Cardiovascular
K
25
0045
uWS-Angio Pro
K
25
0040
uWS-Angio
K
24
2314
Minimally Invasive Prostate Surgery Navigation System(Model:AmaKris SR1-A-2)
K
25
2608
AI-Rad Companion Prostate MR
K
25
1168
Image Suite
K
25
0290
SurgiTwin
K
25
2526
Rapid DeltaFuse
K
24
3680
Neurovascular Insight V1.0
K
23
2456
RW-1
K
25
0664
Navigo Workstation 2.3 (FPRMC00039)
K
25
1038
Digital Radiographic Imaging Acquisition Software - DR (RiasDR)
K
24
4016
iPETcertum (v1.0)
K
25
0716
IMAGE ONE
K
24
3681
Neuro Insight V1.0
K
25
0686
GyriCalc (Version 1.0.0)
K
25
0181
AV Viewer
K
25
0120
GECHO
K
25
1863
CustomSurg OrthoPlanner
K
24
3666
uOmniscan
K
24
4012
Mosaic (V1.0.1)
K
25
0800
UroNav 4
K
24
3703
TechLive
K
25
1109
SMARTDent
K
24
3632
uWS-Angio Basic
K
24
3069
LUMYS (V1)
K
24
3697
MySpine WebPlanner
K
24
3651
VersaViewer
K
24
2647
MySegmenter (v2.0.0)
K
25
0301
Merge Universal Viewer (MUV)
K
24
2552
Horos Mobile
K
24
3292
brAIn™ Shoulder Positioning
K
24
2161
Radlink GPS Pro Imaging
K
24
1975
SERV MEDICAL CDSS
K
24
1765
PLANET Onco Dose (3.2)
K
24
1546
aiCockpit AI Viewer
K
25
0348
JLK-AILink
K
24
2838
QuickRad
K
24
2240
CaRi-Plaque
K
24
1425
AspenView
K
24
3333
rTOP
K
24
1694
ZeTTA PACS
K
24
1819
CephNinja
K
24
2205
SpectoMed (v1.0)
K
24
1808
ApolloHipX (THR.SS.0001)
K
24
2123
Brainomix 360 e-CTA
K
24
1350
Clarify DL
K
24
2599
aprevo® Digital Planning
K
24
2362
Lightning Viewer
K
24
1989
Cercare Medical Neurosuite (CMN) Capillary Function with Virtual Expert
K
24
0926
PeekMed web
K
24
3447
Rapid Surgical Plan (RSP-SW-001)
K
24
2810
RadUnity (Version 1.0.0)
K
24
1495
Jazz Classic
K
24
2329
CT Collaboration Live
K
24
2062
1CMR Pro
K
24
1981
Change Healthcare Stratus Imaging PACS
K
24
2709
JLK-PWI
K
24
1223
eRAD PACS
K
24
2512
ROCC Console
K
24
3012
MIM – Symphony HDR Fusion
K
24
3209
nordicMEDiVA
K
24
2556
JLK-CTP
K
24
0385
VINT
K
24
1569
syngo Application Software
K
24
0243
EConsole2
K
24
1524
Elucid PlaqueIQ
K
23
3998
TRAQinform IQ
K
24
1302
SonoSync
K
24
0290
AiMIFY (1.x)
K
24
1094
Bullsai
K
24
0724
SynthVISION 1.0.0
K
23
3761
Orthopaedic Surgery Planning Software (AIJOINT)
K
24
1114
EzDent-i / E2 / Prora View / Smart M Viewer (v3.5)
K
24
1879
vRad Viewer
K
24
1121
MICSI-RMT
K
24
0705
Vitrea Software Package, VSTP-002A V2.0
K
24
1300
ViewPoint 6
K
23
3908
cNeuro cDAT
K
24
1608
nordicMEDiVA
K
23
3331
MediOMx
K
24
0281
Bone Suppression Software
K
22
3427
Mimics Enlight CMF
K
24
0294
Syngo Carbon Enterprise Access (VA40A)
K
23
2759
Viewer (5.4); Elements Viewer; Mixed Reality Viewer; Smart Layout; Elements Viewer Smart Layout
K
23
3620
MIM - Centiloid Scaling
K
23
2862
MIM – Monte Carlo Dosimetry
K
23
2976
VUZE System
K
23
2514
MIM – Dose Analysis
K
23
3699
SubtleREFORMAT (1.x)
K
24
0839
OpenRad Cloud
K
24
0822
Image Management V15
K
23
3582
Rapid
K
23
2641
Neorad Pacs (Neorad Pacs)
K
23
2891
CARPL (CARPL)
K
24
0620
Cube Navigator
K
23
3660
nCommand Lite System
K
23
3599
X-Clever (ASHK100G)
K
23
3930
MRCP+ version 2 (MRCP+ v2)
K
23
3572
Autofuse
K
23
3217
Mimics Cardiac Planner
K
23
1662
Aid-U
K
23
2339
Augmented Reality Application
K
23
2007
CAAS MR Solutions
K
23
1396
CEPHX- Cephalometric Analysis Software
K
23
3714
BreView
K
23
1607
Axial3D Cloud Segmentation Service
K
23
3226
FlexView Diagnostic (v1.1.20)
K
23
2589
Horos MD™
K
23
2744
syngo Virtual Cockpit (VB10A)
K
23
3176
uOmnispace.MI
K
23
0955
syngo Application Software
K
23
1570
StrokeViewer Perfusion
K
23
3634
TeleScan
K
23
1898
DTX Studio Clinic (4.0)
K
23
2661
Myocardial Strain Software Application
K
23
1498
TraumaCad Neo
K
23
0856
BrainSpec Core™ Software
K
23
0854
SwiftMR
K
23
2086
spineEOS
K
22
3909
R2GATE Lite TM
K
23
1225
EConsole1
K
23
0249
Ikshana
K
23
1642
Veuron-Brain-pAb3
K
23
0252
OFIX MIS App
K
22
3659
Jazz
K
23
1385
Rology Teleradiology Platform (v.1.22.1103)
K
23
2189
OrionXR
K
23
1353
AccuCTP Pro
K
22
0034
NEUROShield
K
23
1047
UniSyn Molecular Imaging (6-3-1)
K
23
1656
Brainomix 360 e-MRI
K
22
3180
AIRAscore
K
23
1503
CUPTIMIZE™ Advanced
K
22
3660
SaintView
K
23
2100
Efai Pacs Picture Archiving and Communication System Pro
K
23
0540
Patient Specific Planning Solution™ 3D Bone Models
K
22
3322
Argus Cognitive ReVISION Software
K
22
2683
Fibroid Mapping Reviewer Application (FMRA)
K
23
1041
JiveX (Model Number / Release: 5.4)
K
23
0016
Cercare Medical Neurosuite
K
22
3290
CommandEP Data Manager PC (DPC02), CommandEP HMD (HMD02)
K
23
1351
Chondral Quant
K
22
3125
XR90 (XR90-SYS)
K
21
3253
Pixyl.Neuro
K
22
3048
Medisystem Pacs
K
22
3091
CT Perfusion V1.0
K
23
1360
Ambra PACS
K
22
3532
Olea S.I.A. Neurovascular V1.0
K
22
3555
Brainomix 360 e-CTP
K
22
3841
KBA3D
K
22
2359
Quicktome Software Suite
K
23
0044
Pre-Sure
K
22
2035
Avatar Medical Software V1
K
23
1162
ROSA Hip System
K
23
0803
ADAS 3D
K
21
2758
Autoplaque
K
22
2854
iTFlow
K
22
3623
SubtleMR (2.3.x)
K
22
2987
Akunah REFLECT
K
22
0437
Neurophet AQUA
K
23
0119
3D Anatomic Model
K
22
1870
CarnaLife Holo
K
23
0552
MR DWI/FLAIR Measurement V1.0
K
23
0906
Konicaminolta DI-X1
K
23
0468
EzDent Web
K
23
0772
Quantib Prostate
K
23
0393
UniCam Evo Software
K
23
0264
Ezra Flash
K
22
2781
Augmento
K
23
0575
Limbus Contour
K
21
3660
RadAlly
K
21
1059
CereFlow™ V1.2
K
22
1984
InterView XP; InterView FUSION
K
23
0561
Syngo Carbon Space VA30A
K
22
3490
FlightPlan for Embolization
K
23
0294
CoverScan (CoverScan v1.1)
K
22
2975
Advantis Platform
K
22
1680
Xeleris V Processing and Review System
K
22
2757
Clarus Viewer
K
21
3891
RealNow
K
22
3820
EzDent-i / E2 / Prora View/ Smart M Viewer
K
23
0196
syngo.via View&GO VA40A
K
22
3425
MD.ai Viewer
K
23
0012
Atomica Planner
K
22
1725
Advanced MyHip Planner
K
22
1627
PerfusionGo Plus
K
22
2593
TruPlan Computed Tomography (CT) Imaging Software
K
22
3800
MIM – Additional Tracers
K
22
0649
Elucis
K
22
3502
MR Diffusion Perfusion Mismatch V1.0
K
22
3363
MAMMOVISTA B.smart (VB70)
K
22
2458
AIBOLIT 3D+
K
22
3336
Vitrea Software Package, VSTP-002A
K
22
2577
TECHFIT Diagnostic Models
K
21
3263
OnyxCeph
K
22
2767
PeekMed web (v1)
K
22
2195
aprevo® Digital Workflow
K
22
1796
Cyware 4H and Cysart 4H
K
22
3071
Xenoview VDP
K
22
2320
MedDream
K
22
0630
TorchTM Software
K
21
3215
VSI HoloMedicine
K
22
3152
Vision 2, EVARVision, TrackVision 2, HeartVision 2
K
22
2054
Denti.AI Auto-Chart
K
22
1499
Minimally Invasive Prostate Surgery Navigation System
K
22
0663
AccuCTP
K
22
2476
OmegaAI Image Viewer
K
22
1677
Synapse 3D Base Tools v6.6
K
22
1478
Dolphin Blue Imaging
K
22
2470
3Dicom MD
K
21
3128
IntraOp VSP Software Device
K
22
2662
Vitrea CT Cardiac Analysis
K
22
1501
syngo.via View&GO
K
22
0758
e-Ortho Shoulder Software v1.1
K
22
2069
Ez3D-i/E3
K
21
3520
AXIR-CX
K
22
0903
WebCeph
K
22
0433
syngo Application Software (VE21)
K
22
2145
EzDent-i / E2 / Prora View/ Smart M Viewer
K
22
0349
TeraRecon Neuro
K
22
2072
Dolphin Imaging 12.0
K
22
1405
Neurophet SCALE PET
K
22
0733
OptiVu ROSA MxR
K
22
0624
AI4CMR v1.0
K
21
3922
FX SPS
K
22
0039
AutoSeg
K
22
1426
Functional MR V1.0
K
22
1511
Axial3D Cloud Segmentation Service
K
21
3665
Syngo Carbon Space VA20A
K
22
1463
ElucidVivo A.3
K
21
3684
SurgiCase Viewer
K
22
1065
MediLab
K
22
0205
3D Anatomic Models
K
22
1270
EchoNavigator R4.0
K
22
0416
SwiftMR
K
22
1000
ON3D
K
22
0832
syngo Dynamics (Version VA40E)
K
21
2565
CoverScan v1
K
21
2376
Caas Qardia
K
22
1106
Quantib Prostate
K
22
0727
inHEART MODELS
K
21
3975
KEOPS Balance Analyzer 3D
K
21
1966
Segment 3DPrint
K
21
3302
exoplan
K
22
0684
Oryx Cloud Imaging
K
22
0590
aPROMISE X
K
21
1713
AngioCloud Service
K
21
2981
MirrorMe3D Modeling System
K
22
0779
XD
K
22
0767
TeleScan
K
20
3783
ClariPulmo
K
21
3562
DTX Studio Clinic 3.0
K
21
2040
RI.HIP MODELER
K
21
2720
nordicDSC
K
22
0003
EzOrtho v1.3
K
21
3165
Rapid
K
21
3801
Veuron-Brain-pAb2
K
21
3737
Quantib ND
K
21
2005
UNiD Spine Analyzer
K
21
1443
AIBOLIT 3D+
K
21
0830
VUZE System
K
21
1156
CONVIVO In Vivo Pathology Suite
K
21
3140
Claritas iPET
K
21
0931
Libby IAAA v1.0
K
21
2420
Brainlab Elements, Brainlab Elements Contouring, Brainlab Elements Fibertracking, Brainlab Elements Image Fusion, Brainlab Elements Image Fusion Angio
K
21
1114
Will3D
K
21
1039
BIT-Motion
K
21
2137
X-Clever
K
20
3743
EXA
K
21
0916
PVmed Contouring Software
K
21
0241
ImplaStation
K
21
1432
Myomics Q
K
21
2984
MiPACS HTML5 Web Viewer
K
21
2621
MAMMOVISTA B.smart
K
21
1876
Intellijoint VIEW
K
21
2887
RTapp
K
21
0344
inVisionOS
K
21
2550
Hura CTP v1.0
K
21
1356
GIQuant
K
21
2896
Visible Patient Suite
K
21
3326
VisionX 3.0
K
21
1987
ATEC Alignment App
K
21
0807
FlightPlan for Liver
K
21
2470
iRAD
K
21
2528
Change Healthcare Cardiology
K
21
0999
SwiftMR
K
20
2808
Brainance MD
K
21
1429
NAVIPLAN - CT Planning Software for Total Hip Replacement
K
21
1795
EzDent-i/ E2/ Prora View/ Smart M Viewer
K
21
0726
ImmersiveTouch
K
21
1700
EzDent Web
K
21
2777
Collaboration Live
K
21
2321
JiveX (Model Number / Release: 5.3)
K
21
2685
KONICAMINOLTA DI-X1
K
21
1257
EFAI PACS Picture Archiving and Communication System
K
20
2056
Kinepict Medical Imaging Tool 4.0
K
21
2421
ADAS 3D
K
20
3696
RBknee
K
21
1793
EzOrtho
K
21
1791
Ez3D-i/E3
K
21
0998
ROSA Hip System
K
20
1573
Brain Perfusion (BP) application
K
21
2230
TruSPECT Radiological Image Processing Station
K
21
1863
eVolve PACS
K
21
2175
DynaCAD
K
21
2074
ClariCT.AI
K
21
1655
aPROMISE
K
21
1279
Volpara Imaging Software
K
21
1386
MySpine WebPlanner & MyBalance
K
20
3765
ZIRKONZAHN.Implant-Planner, ZIRKONZAHN.Implant-Planner Practice, CAD/CAM STL Converter, CAD/CAM Z-Tray
K
21
1480
NubeX
K
20
1835
PRE-SURE
K
21
0653
ONE Planner Hip
K
21
1656
3D Echo v1.1
K
20
2718
Qmenta Care Platform Family
K
20
0704
ZedView
K
21
1312
Universal Viewer
K
21
0257
Xoran Workstation, Model 10050
K
21
0187
Overjet Dental Assist
K
20
2793
Cercare Medical Neurosuite
K
21
0072
HOLOSCOPE-i
K
21
0066
ImagePilot
K
21
0682
SOTA Cloud Imaging
K
20
2521
PtoleMedic System
K
20
2084
DeepLook PRECISE
K
21
0850
ADAS 3D
K
20
3195
Simpleware ScanIP Medical
K
21
0071
SIS System (Version 5.1.0)
K
20
3518
Quicktome
K
20
3651
Cuptimize
K
20
3182
SubtleMR
K
20
2990
NinesMeasure
K
20
2212
TruPlan
K
20
0589
MyPAO Planning Report
K
21
0136
PhantomMSK Hip
K
20
3312
Vitrea Software Package, VSTP-001A
K
20
3103
Synapse 3D, Synapse 3D Base Tools v6.1
K
20
3290
Bonelogic
K
20
3582
QUIBIM Precision Prostate (qp-Prostate)
K
20
3104
IBM iConnect Access
K
20
3677
ViewPoint 6
K
20
3142
Veuron-Brain-pAb
K
20
2847
AccuBrain
K
20
2414
BrainInsight
K
20
2229
AI Metrics
K
20
1250
SQuEEZ Software
K
20
3249
Nucleus.io
K
20
2487
HealthJOINT
K
20
0572
Planmeca Romexis
K
20
3156
DTX Studio Clinic
K
20
2805
Optimized Positioning System (OPS) Insight
K
19
3287
CorInsights MRI
K
20
3287
DBSWIN, VISTAEASY
K
19
3306
PROView
K
20
0750
Neuro.Al Algorithm
K
20
0350
MyHip Planner & Verifier
K
20
3058
CloudVue
K
20
2519
OrthoNext Platform System
K
20
2948
EzOrtho
K
20
1710
A View LCS
K
20
2501
Quantib Prostate
K
20
0810
IPS CaseDesigner
K
20
2292
UDE
K
20
2280
Cleerly Labs v2.0
K
20
1928
e-Ortho Shoulder Software
K
19
2051
THINQ
K
20
1103
Xeleris V Processing and Review Systems
K
20
0603
AAA Model
K
20
0852
EchoPAC Software Only, EchoPAC Plug-In
K
19
2890
SentEP
K
20
1369
AVA (Augmented Vascular Analysis)
K
20
1665
Collaboration Live
K
20
2297
Aline Ablation Intelligence
K
20
2256
3Shape Implant Studio
K
20
1948
AcroDTI Visualizer
K
20
2335
Ambra ProViewer
K
20
0973
Synapse 3D Cardiac Tools
K
20
0714
AVIEW
K
20
2116
EzDent-i/ E2/ Prora View/ Smart M Viewer
K
20
1352
3D Auto LAA
K
20
1632
TOMTEC-ARENA
K
20
1232
Limbus Contour
K
20
0822
Braid
K
20
1465
SuRgical Planner (SRP) BrainStorm
K
20
1365
True 3D Viewer
K
19
3294
AI-Rad Companion Engine
K
20
1296
i-Rapha Solution
K
20
1477
syngo.via View&GO
K
19
3042
Optimized Positioning System (OPS) ReView
K
19
3290
AI-Rad Companion Brain MR
K
20
0899
Quantib AI Node
K
19
2630
uWS-MI
K
20
1202
MI View&GO
K
19
2692
Brainomix 360 e-CTA
K
20
0274
CariCloud
K
20
1062
syngo Ultrasound Apps Suite (sUSAS)
K
20
0546
ZeeroMED View
K
20
0315
Ziostation2
K
19
3220
AVIEW LCS
K
19
2656
Optimized Positioning System (OPS) Insight
K
19
3523
ArthrexVIP Web Portal
K
19
2475
NemoFAB
K
20
0703
JiveX
K
19
3369
Xelis Dental 2.0
K
20
0078
VARO Plan
K
20
0713
EchoNavigator
K
19
2176
IntelePACS
K
19
0767
AnatomicAligner
K
19
2888
EzOrtho
K
19
0993
Kinepict Medical Imaging Tool version v2.2
K
19
2962
icobrain-ctp
K
20
0178
Ez3D-i /E3
K
19
2973
densitas densityai
K
20
0179
Collaboration Live
K
20
0132
Ashvins
K
19
2923
Vitrea Software Package
K
19
2372
ASCEND Image Viewer
K
19
3498
Infinitt RT PACS
K
19
2165
Acteon Imaging Suite
K
19
2462
syngo.MR Applications
K
19
3261
FlightPlan for Embolization
K
19
1014
Elements Viewer
K
19
2098
EzMobile
K
19
1125
ADAS 3D
K
19
2917
ViewPoint 6
K
19
2912
AutoMIStar
K
19
3403
UroNav System
K
19
3149
True 3D Viewer Software
K
19
2040
AVIEW Modeler
K
18
3676
DentiqAir
K
19
2531
QyScore Software
K
19
2130
Icobrain
K
19
2571
NemoScan
K
19
2279
PhantomMSK Trauma
K
19
2348
SICAT Implant V2.0
K
19
2038
Emprint Visualization Application
K
19
2508
Medsynapse Ris Pacs & Medsynapse VNA
K
19
1278
RSI-MRI+
K
19
1959
QuantX Breast MRI Biopsy Guidance Plugin
K
19
1026
MEDIP PRO
K
19
2109
KOALA
K
19
0868
Cleerly Labs
K
19
2743
VisionX 2.4
K
18
3412
mediCAD Web
K
19
1544
Synapse 3D Blood Flow Analysis
K
19
2455
Merge PACS
K
19
1216
Voxel Dosimetry™ v1.0
K
19
0162
SmartCeph
K
19
1493
Ventripoint Medical System Plus (VMS+) 3.0
K
19
2200
DynaCAD
K
19
1610
RTapp
K
19
2435
NuVasive NuvaLine
K
19
1530
StoneChecker
K
19
2276
Merge Cardio
K
19
1688
SubtleMR
K
19
2304
SIS Software Version 3.6.0
K
19
0780
syngo Application Software
K
18
3489
D2P
K
18
3544
Efficient Care 3D Planning
K
18
3458
exoplan 2.3
K
19
1262
aBSI
K
18
3193
MREplus+ Software
K
19
1309
syngo.via MI Workflows VB40A, Scenium
K
19
1585
iNtuition-Structural Heart Module
K
19
0694
Unifi Workspace v1.0.0
K
18
2904
syngo.MR Applications
K
19
0096
R2GATE
K
18
3170
uWS-CT
K
19
0913
QLAB Advanced Quantification Software 13
K
18
3460
ClariCT.AI
K
19
0874
Materialise Mimics Enlight
K
19
1188
ASHK100G
K
19
1040
syngo.via (Version VB40A)
K
19
0764
SurgicalAR
K
19
0866
XmaruView V1 (Xmaru Chiroview, Xmaru Podview)
K
19
0042
Brainlab Elements Image Fusion Angio
K
18
3248
Synapse Enterprise Viewer Version 1.0
K
19
0791
Ez3D-i/E3
K
18
3593
Lung Vision System
K
19
0420
NDOHD High Definition Imaging System (NDOHD)
K
18
2572
InstaRISPACS / InstaZFP / InstaMobi v5.0
K
19
0629
DBSWIN and VISTAEASY Imaging Software
K
18
3210
Thoracic VCAR with GSI Pulmonary Perfusion
K
18
3105
Mimics Medical
K
19
0232
Synapse PACS
K
18
3164
uWS-MR
K
19
0379
MIM on Linux
K
18
3019
SIS Software version 3.3.0
K
18
2537
RADMAX Digital Imaging Software
K
18
2966
PLANET Onco Dose
K
18
1859
Visualase Thermal Therapy System
K
18
3478
ClearON Mobile
K
19
0087
EzDent-i / E2 / Prora View
K
18
2643
IRIS 1.0 System
K
18
2332
PhantomMSK
K
19
0074
Presero 3D Scanning System
K
18
3272
AI Rad Companion (Engine)
K
18
3133
MRCP+ v1.0
K
18
2855
ProKnow DS
K
18
0867
AmCAD-UO
K
18
2564
Quantib ND
K
18
2130
iSchemaView RAPID
K
18
3012
vascuCAP
K
18
2750
4D View
K
17
3041
3DIEMME RealGUIDE
K
18
2624
MIM - MRT Dosimetry
K
18
2601
Vitrea Software Package, VSTP-001A
K
18
2419
Centricity Universal Viewer
K
18
2359
HipCheck
K
18
2926
IntelliSpace Radiology
K
18
2016
Simplicit90Y
K
18
1825
CAAS MR Solutions
K
17
3083
IMPLANTER DENTAL PLANNING SOFTWARE
K
18
2815
XVWeb 3D
K
18
3038
Corin Optimized Positioning System (OPS) Plan
K
18
3013
Vitrea Software Package, VSTP-001A
K
18
2431
Konicaminolta DI-X1
K
17
3744
ProFuse CAD
K
18
1247
Vitrea CT Brain Perfusion
K
17
2999
uWS-MR
K
17
3001
uWS-CT
K
18
1939
icobrain
K
17
1199
AVIEW
K
17
3965
Implant Planning Software
K
18
2464
PeekMed
K
18
1964
JiveX
K
18
2561
UroNav (Version 3.0)
K
18
2034
Arterys MICA
K
18
1460
OnePacs System
K
18
1892
Ziostation2
K
18
2290
IBM iConnect Access
K
18
1773
Synapse 3D Optional Tools
K
18
0916
iNtuition-T1 Mapping and T2/T2* Mapping
K
18
2310
Volpara Imaging Software
K
18
1926
InVivo Web Viewer
K
17
2418
OpenSight
K
18
2230
Multi Modality Viewer
K
18
2208
syngo.via View&GO (Version VA10A)
K
17
0702
mediCAD 4.0
K
18
0006
AmCAD-UT Detection 2.2
K
18
1185
Change Healthcare Enterprise Viewer
K
18
0522
IGTFusion
K
18
1318
ONIS-PACS
K
18
1962
CubeVue
K
17
1435
VirtuOst Vertebral Fracture Assessment
K
17
1977
miPlatform medical imaging suite v3.0 (miPlatform v3.0), miPlatform ZFP Viewer
K
17
3444
Quantitative Total Extensible Imaging (QTxI)
K
18
0629
DentiqGuide
K
17
3274
Ceevra Reveal 2.0
K
17
3574
DenSeeMammo
K
18
0815
MIM - SPECTRA Quant
K
17
2346
sterEOS Workstation
K
18
1290
Fusion Bx 2.0
K
17
3780
EchoMD Automated Ejection Fraction Software
K
18
1264
QLAB Advanced Quantification Software
K
18
1177
Interventional Workspot
K
18
1080
McKesson Cardiology
K
18
0883
5D Viewer
K
18
0641
Invenia ABUS Viewer
K
17
3390
hipEOS
K
18
0563
syngo.plaza
K
17
2768
ZOOM
K
18
0161
Viz CTP
K
18
0336
syngo.MR Applications
K
17
2477
iSchemaView RAPID
K
18
0549
ZED Link
K
18
0125
PowerLook Density Assessment Software
K
17
3897
syngo.via MI Workflows
K
17
2998
uWS-MI
K
17
1847
Corin Optimized Positioning System (OPS™) Plan
K
17
3597
Scenium VE20 Software
K
17
2239
SIMPLANT 18
K
18
0323
Vitrea Software Package; VSTP-001A
K
17
3241
MED-TAB
K
18
0192
Emprint Ablation Visualization Application
K
17
3619
Mimics inPrint
K
17
2168
WillCeph
K
18
0129
Imbio Segmentation Editing Tool software
K
17
3611
syngo Application Software
K
18
0262
SICAT Endo
K
18
0394
BrightMatter Plan 1.6.0
K
17
3939
Quantib Brain
K
18
0326
icobrain
K
17
3605
iQMR
K
17
3312
ProBx Software
K
17
3145
CereMetrix Silver
K
17
3863
Ez3D-i /E3
K
17
0540
DM-Density
K
17
3636
Velocity
K
17
0793
SuRgical Planner (SRP)
K
18
0091
UNiD Spine Analyzer
K
16
2727
SENYINT Remote Consultation System
K
17
2832
Insight BD
K
17
2490
eUnity
K
17
3512
MFI-Cardiac
K
17
3088
Vitrea Software Toshiba Package VSTP-001A
K
17
3542
Arterys Oncology DL
K
17
3622
CS Imaging
K
17
3054
Navigo Workstation Version 2.0
K
17
3588
Illumeo System
K
17
2224
DTX Studio diagnose
K
17
1328
cNeuro cMRI
K
17
3456
ViewPoint 6
K
17
3420
Radiomics App v1.0
K
17
3467
Advanced Diffusion Analysis (ADA) application
K
17
3475
Merge PACS
K
17
2218
MIM – Y90 Dosimetry
K
17
3378
syngo®.via protoNeo (Version VA20)
K
17
3329
jFit Surgical Planner
K
17
1385
Planmeca Romexis
K
17
3247
Surgical Planning Software version 1.1
K
17
2803
Infinitt PACS 7.0
K
17
3094
OrthoVision
K
17
1709
BR-FHUS Viewer 1.0
K
16
3623
Quantra
K
17
3101
Curve Image 2.0 PACS
K
17
1068
OrthoView 7.2
K
17
2855
Vitrea Advanced Visualization, Version 7.6
K
17
1463
ASPIRE Bellus II
K
17
0816
Elements Image Fusion, Elements Cranial Distortion Correction, Elements Spine Curvature Correction, Elements TRAM
K
17
2513
3D Echo
K
17
0981
NeuroQuant
K
17
2327
VMA™ System version 3.0
K
17
2364
EzDent-i / E2 / Prora View
K
17
1617
OKI Surgical Planning Software
K
17
1356
Clarity Reveal
K
17
1754
NovaPACS
K
16
3048
Smart Stitching Software System, Image Processing, Radiological
K
17
0841
BiopSee, Mobile US
K
16
3232
Vitrea View
K
17
1544
Arterys Viewer
K
17
0729
Examion X-AQS
K
17
1115
3D Endo Software
K
17
0434
Enterprise Imaging XERO Viewer 8.1
K
16
3668
SUITESTENSA
K
17
0847
EchoPAC Software Only, EchoPAC Plug-in
K
17
0747
syngo Application Software
K
17
1222
Vitrea Software Toshiba Package; VSTP-001A
K
17
0250
SmartTarget
K
17
1053
syngo Dynamics Version VA30
K
17
1314
QLAB Advanced Quantification Software
K
16
2574
AmCAD-US
K
17
0172
UNiD Spine Analyzer
K
16
3071
vascuCAP
K
17
0195
QuantX
K
16
1601
Dynamika
K
17
0419
SurgiCase Viewer
K
16
3622
Lung Vision
K
16
3250
Longitudinal Brain Imaging (LoBI) application
K
17
0180
Will3D
K
17
1130
Nucleus Image Management System
K
16
3119
NaviSuite SSI Edition
K
16
2647
NuVasive NuvaLine Mobile App
K
17
0952
syngo.CT View&GO
K
17
0069
AmCAD-UV
K
16
2799
Cliniview
K
17
0580
Carestream Vue PACS
K
16
2287
Synapse 3D Perfusion Analysis
K
16
3076
Segment CMR
K
16
1341
LIFESYS PACS
K
16
2559
Move Forward 3D Motion Simulation Service
K
16
3290
INFINITT ULite
K
16
3405
360KS Implant Positioning System
K
16
2868
Exam Vue PACS
K
17
0451
FDX Console (DR-ID300CL) Software
K
17
0167
True 3D Viewer Software
K
16
2484
Lung Nodule Assessment and Comparison Option (LNA)
K
16
3285
syngo Application Software
K
16
2830
SIS Software
K
16
3294
syngo.MR General, syngo.MR Cardiology, syngo.MR Neurology
K
16
0934
UC-CARE NaviGo Workstation
K
16
3122
NobelClinician, DTX Studio implant
K
16
3324
nordicBrainEx
K
16
2285
EBM iDO Viewer 1.2.1
K
16
3574
Multi Modality Viewer
K
16
3533
EzDent-i; E2; ProraView
K
16
1841
D2P
K
16
3013
Quantib Brain 1.2
K
16
3253
Arterys Cardio DL
K
16
1270
CephSimulation
K
16
3421
syngo.via MI Workflows
K
16
1959
ClearView cCAD
K
16
3539
Ez3D-i / E3
K
16
2955
Multi-Modality Tumor Tracking (MMTT) application
K
16
0852
Zia
K
16
2376
CAAS MR 4D Flow
K
16
1322
CT CoPilot
K
15
2009
DENSEEMAMMO v1.0
K
16
3158
MEDSYNAPSE Zero Footprint Viewer
K
16
2743
ViewPoint 6
K
16
2541
syngo Application Software
K
16
1515
eUnity
K
16
1634
IPS CaseDesigner
K
16
2513
Arterys Software v2.0
K
16
2145
vRad PACS with Mammography
K
16
2474
Artemis
K
16
2025
IntelliSpace Portal Platform
K
16
2011
MedDream
K
16
0371
NovaPACS
K
16
1109
iSR'obot MRI-US Fusion
K
16
0666
Dentiq3D
K
16
1828
kneeEOS
K
16
2339
Scenium
K
16
2112
CAAS MRV
K
16
1625
PixelShine
K
16
2008
JiveX
K
16
2141
Restore PACS
K
15
3705
PROcedure Rehearsal Studio
K
16
1130
ResolutionMD
K
16
1518
PACS CORE/ENCORE
K
15
2949
WebPAX
K
16
1955
5D Viewer
K
16
1148
icobrain
K
16
1113
QXLink
K
16
0284
JointPoint
K
16
0937
Senolris
K
16
1382
LVivo Software Application
K
16
1118
SIMPLANT Online Case Review and SIMPLANT Editor
K
16
1419
Multi Modality Viewer
K
16
1685
syngo®.via protoNeo (Version VA10A)
K
16
1479
hipEOS
K
16
0584
Surgical Navigation Advanced Platform (SNAP)
K
16
1559
Kuvia3D
K
16
1061
IMPAX Volume Viewing 4.0
K
16
1444
DBSWIN and VistaEasy Imaging Software
K
16
0334
Advanced Medical Imaging Software Suite (KSWVWR)
K
15
3351
Quantib Brain 1
K
16
1188
HEPATIQ 1.1
K
16
1246
Ez3D-i / E3
K
15
3736
3mensio Workstation
K
16
1117
EzDent-i / E2 / Prora View
K
15
1913
MIM-Thin Client (mobile)
K
16
0914
sterEOS Workstation
K
15
3653
DICOM Viewer
K
16
0376
EndoSize
K
16
0579
Xmaru View V1 and Xmaru PACS, Medical Image Processing Software
K
16
0407
spineEOS
K
15
3284
Synaptive ImageDrive Pro
K
15
2716
EV Insite System
K
16
0150
Vitrea CT Colon Analysis
K
15
3355
Xeleris 4.0 Processing and Review Workstation
K
15
3612
ArthrexVIP Web Portal
K
16
0426
syngo.via MI Workflows
K
15
3346
syngo Application Software VD11
K
15
2602
Olea Sphere V3.0
K
16
0317
syngo.via MI Workflows
K
15
3091
IMPLANT 3D
K
15
1737
MedicVOD System
K
15
2034
FS-PACS
K
16
0315
I4 (Integrated Intelligent Imaging Informatics) system
K
14
3290
DBSWIN and VistaEasy Imaging Software
K
15
3593
CliniscanSM MRI
K
16
0001
TraumaCad Mobile Release 2.0
K
15
3103
CARESTREAM Vue PACS
K
16
0108
Synapse PACS
K
15
3166
Fusion Bx
K
15
2977
DG PACS
K
15
2352
Stereo 3D option for Vision Applications
K
15
3289
HEALTHMYNE
K
15
1075
BR-ABVS Viewer 1.0
K
15
1152
ImplantMax Software
K
15
3427
Volpara Imaging Software
K
15
2746
Ez3D Plus
K
15
2172
Econsole1
K
15
2078
Implant Studio 2015
K
15
2822
VidiStar HeartView
K
15
3022
Philips IntelliSpace Cardiovascular
K
15
3073
UroNav (Version 2.0)
K
15
2661
HICAT Air
K
15
1212
Ziostation2
K
15
2028
Volpara Imaging Software
K
15
1988
Visible Patient Suite
K
15
1941
DEXIS Webview
K
15
1501
OrthoVis Web Portal
K
15
1774
CARESTREAM Vue Motion
K
14
3586
FACT Medical Imaging Sysytem
K
15
1957
BOX DICOM Viewer
K
15
2186
HealthMyne PACS
K
15
1837
CS 3D Imaging
K
15
1371
Corporate Dental Imaging (CDI) Application
K
15
1859
Synapse Cardiovascular
K
15
1850
McKesson Cardiology
K
15
1353
syngo.MR Neurology, syngo.MR Oncology
K
15
1687
QuantorView
K
15
1568
Arthrex OrthoVis Preoperative Plan
K
15
1808
3D/5D Viewer
K
14
3368
GenIQ
K
15
1854
3MP (X213C3P0E, X213G3P0E) and 2MP (X213C2P0E, X213G2P0E) LCD Display
K
14
3176
UltraLinq
K
15
1091
Vitrea Software Toshiba Package, VSTP-001A
K
15
0313
Ablation Confirmation
K
15
1438
Dentrix Ascend Imaging
K
14
2750
JiveX
K
15
1192
syngo.via MI Workflows
K
15
0415
NilRead
K
15
0761
Ez3D-i/E3
K
15
0976
Collage
K
15
1115
MR Core Software
K
14
3397
ICIS View
K
15
0707
IntelePACS
K
15
0420
Centricity Universal Viewer
K
15
0069
Fine Structure Analysis(fineSA)
K
14
2648
SPINEDESIGN Spine Surgery Planning (Software Application)
K
14
2196
Visage Ease Pro
K
15
0843
syngo®.via (version VB10A)
K
14
2779
SCANIP; SCANIP: MEDICAL EDITION; SCANIP: MED
K
14
2647
mint Lesion
K
15
0738
VitreaView
K
15
0747
EzDent-i /E2/Prora View
K
15
0192
Scenium
K
14
3361
Mammo Workstation
K
15
0193
Customer Remote Console (CRC)
K
14
2337
Blackford Analysis Registration Product Family
K
14
3318
DR Systems Zero Download 3D Viewer (Z3D)
K
14
1536
VIEWING CLIENT MOBILE
K
15
0258
Vitrea, Version 7.0 Medical Image Processing Software
K
14
2923
TraumaCad Mobile Release 1.0
K
15
0085
GE EchoPAC
K
14
3319
Syngo X-workplace SW VD10
K
15
0122
TOMTEC-ARENA TTA2
K
14
3044
CAAS A-Valve
K
14
0828
NEUROREADER MEDICAL IMAGE PROCESSING SOFTWARE
K
14
2107
ECHO TRUE 3D VIEWER
K
14
1561
VM PACS WITH VM MEDICAL WORKSTATION
K
14
2850
McKesson Radiology Mammography Plus
K
14
2316
IMPAX Agility
K
14
0587
MR-CT VVA
K
14
2514
UniWeb 8.0
K
14
2891
HEPATIQ
K
14
2944
ArthroPlan Digital Templating Software
K
14
2919
EXA
K
14
0860
ImmersiveTouch3 and MicrovisTouch
K
14
0797
IPACS MEDICAL IMAGE MANAGEMENT SYSTEM
K
14
3254
eSie Apps Suite
K
14
2671
ONEFIT HIP PLANNER
K
14
3079
Endovascular Stent Planning Software
K
14
2521
Synapse 3D Liver and Kidney Analysis
K
14
1881
RAPIDRESULTS
K
14
1745
IQQA-BODYIMAGING SOFTWARE
K
14
1570
IMPLANT STUDIO
K
13
2853
NOVAPACS
K
14
2037
QUANTRA
K
14
1669
SURGIMAP
K
14
1607
DENTAL IMAGING SOFTWARE
K
14
0399
EBM IDO VIEWER
K
14
2048
EMPRINT PROCEDURE PLANNING APPLICATION
K
14
1137
STEREOS WORKSTATION
K
14
1514
SYNAPSE 3D TENSOR ANALYSIS
K
14
1364
CLIMB MAMMOGRAPHY VIEWER SOFTWARE
K
14
1451
VixWin Platinum
K
14
1480
CVI42
K
13
1348
ORTOMED
K
14
1302
VITREA CT MULTI-CHAMBER CARDIAC FUNCTIONAL ANALYSIS (CFA)
K
14
1061
REMOTEYE VIEWER
K
14
1475
ENDOSIZE
K
14
0897
SYNGO.MR NEUROLOGY, SYNGO.MMR GENERAL
K
14
1554
ESIE APPS SUITE
K
14
0869
DCAS I
K
14
1556
AVREO INTERWORKS SYSTEM
K
14
0909
MCKESSON RADIOLOGY
K
14
0819
SURGICAL NAVIGATION ADVANCED PLATFORM
K
14
1329
RADSPA
K
14
1199
QUENTRY DOSE REVIEW
K
14
0713
PLANMECA ROMEXIS
K
14
0960
PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
K
13
3098
SENYINT PACS
K
14
0434
MEDICAD CLASSIC
K
14
0337
BRIGHTMATTER PLANNING SOFTWARE
K
14
0139
CLEARVIEWHD
K
13
2684
MEDWS SOFTWARE (VARIANTS MEDVIEW, MEDDIAG, MEDMAMMO)
K
14
0395
VITREA IMAGE DENOISING SOFTWARE
K
14
0445
DEXIS SOFTWARE: DEXIS IMAGING SUITE, DEXIS MAC
K
14
0808
Q-STATION
K
13
3521
AZE PHOENIX SOFTWARE
K
13
3910
NORDICBRAINEX
K
14
0271
TABLET VIEWER SOFTWARE FOR IMAGE SUITE
K
13
3984
CORONIS 5MP
K
13
3508
RESOLUTIONMD MOBILE
K
13
3663
NIO COLOR 2MP
K
13
3401
SYNO MR NEUROLOGY, SYNGO MR ONCOLOGY, SYNGO. MR BREVIS, SYNGO MMR GENERAL
K
14
0093
TABLE
K
13
3135
IMPAX VOLUME VIEWING 3.0
K
13
3966
MODEL-BASED RSA SOFTWARE
K
13
3022
ZEDVIEW
K
13
3937
HEARTSCAN SOFTWARE
K
13
3654
SCENIUM
K
13
3609
THE DOME S6C
K
13
2763
ADVANCED VIEWER
K
14
0033
TARGET3D FUSION
K
13
3385
LUNGPOINT ATV PLANNING AND NAVIGATION SOFTWARE
K
13
3644
SYNGO.VIA MI WORKFLOWS
K
13
3320
SICAT FUNCTION
K
14
0214
30.0 INCH COLOR LCD MONITOR CCL650I2 (CL30650, MD302C6)
K
14
0103
3MP GRAYSCAKE LCD DISPLAY
K
14
0108
3MP COLOR LCD DISPLAY
K
13
3708
MD302C4 29.8 DIAGNOSTIC IMAGING LCD MONITOR
K
13
2824
CARESTREAM VUE PACS VERSION 11.4 CARESTREAM VUE MOTION APPLICATION
K
13
4002
6MP COLOR LCD MONITOR, RADIFORCE RX650
K
13
3730
CO PILOT/REGIUS UNITEA
K
13
2770
DOME S10
K
13
3030
DYNACAD/PROSTATE INTERVENTIONAL (DYNALOC/PROSTATE)
K
13
2499
ICRCO CLARITY VIEWER
K
13
3875
THE KINEGRAPH VMA (VERTEBRAL MOTION ANALYZER) SOFTWARE VERSION 2.2, THE MOTION NORMALIZER PATIENT HANDLING AND DATA
K
13
3686
21.3 INCH (54 CM) INCH MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS35i2 (ML21035)
K
13
0998
SYNGO.VIA WEB VIEWER
K
13
2095
OLEA SPHERE
K
13
1447
INTUITION - TDA, TVA, PARAMETRIC MAPPING
K
13
3367
ORTHOVIS PREOPERATIVE PLAN
K
13
2342
XVWEB
K
13
3511
21.3 INCH(54 CM) MONOCHROME LCD MONITOR MS25I2(ML21025)
K
13
2963
FUSIONSYNC, CHIMAERA FUSIONSYNC
K
13
2773
SIDEXIS 4
K
13
2532
SYNGO.PLAZA VB10A
K
13
3181
21.3 INCH (54 CM) COLOR LCD MONITOR CCL258I2 (CL21258)
K
13
3185
21.3 INCH (54 CM) COLOR LCD MONITOR CCL358I2 (CL21358)
K
13
2742
M-VU BREAST DENSITY
K
13
1390
JUSHA-M52C MEDICAL DISPLAY
K
13
3357
CHARRUAPACS SYSTEM
K
13
2544
TOMTEC-ARENA 1.0, TOMTEC-ARENA 3D ECHO, CARDIO-ARENA
K
13
2799
CLARISO PACS
K
13
2586
PAXERAPACS
K
13
2316
MULTIVIEW
K
13
2188
MAMMOGRAPHY VIEWER SMV658
K
13
2636
DYONICS PLAN HIP IMPINGEMENT PLANNING SYSTEM
K
12
1447
ISCHEMA VIEW RAPID
K
12
2536
AMCAD-UT DETECTION MODEL 2.0
K
13
1873
NDOHD HIGH DEFINITION IMAGING SYSTEM (NDOHD)
K
13
1685
GE ECHOPAC
K
13
1977
CENTRICITY UNIVERSAL VIEWER ZERO FOOTPRINT CLIENT
K
13
2302
QXLINK
K
13
1389
JUSHA-C31 MEDICAL DISPLAY
K
12
3944
KOSTEC MEDICAL GRADE LDC MONITORS
K
13
2610
5MP GRAYSCALE LCD DISPLAY
K
13
2587
MD242C2 24 DIAGNOSTIC IMAGING LCD MONITOR
K
13
1594
EZDENTI-I; E2; PRORA VIEW
K
13
1616
EZ3D-I, E3
K
13
0374
OMNI-VUE 2 SYSTEM
K
13
0242
MAVEN PRO
K
13
1391
JUSHA-M32 MEDICAL DISPLAY
K
13
1158
CORVIEW
K
13
0749
SYNGO.MR GENERAL; SYNGO.MR CARDIOLOGY; SYNGO.MR VASCULAR
K
13
1570
ORTHOVISION
K
13
0779
LVIVO EF SYSTEM
K
13
2165
QLAB QUANTIFICATION SOFTWARE
K
13
0743
THE KINEGRAPH VMA (VERTEBRAL MOTION ANALYZER) SOFTWARE VERSION 2.0; THE MOTION NORMALIZER PATIENT HANDLING AND DATA COLL
K
13
1448
3D PROSTATE SUITE 3DTRUS PROSTATE MAPPING, MRI/3DTRUS FUSION OPTION, SECOND LOOK 3DTRUS FUSION OPTION
K
13
1498
IQQA-LIVER MULTIMODALITY SOFTWARE
K
13
2062
ESIE APPS SUITE
K
13
1822
ULTRAEXTEND USWS-900A V2.1 AND V3.1
K
13
1137
21.3 INCH MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS55I2 (ML21055, MD211G5)
K
13
1424
MIPLATFORM MEDICAL IMAGING SUITE
K
13
1090
2MP COLOR LCD MONITOR, RADIFORCE MX215
K
13
0724
CODIAGNOSTIX IMPLANT PLANNING SOFTWARE
K
13
0542
SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS
K
13
1392
ETIAM PACS COMPONENTS
K
13
1295
NIO COLOR 3MP LED
K
13
0278
MR PERMEABILITY
K
13
1246
CORONIS 3MP
K
13
1299
ANYTHINK PACS WORKSTATION
K
12
3306
NORDIC TUMOREX
K
12
4051
THE VAULT SYSTEM
K
13
1118
4D VIEW
K
12
3082
MOBILECT VIEWER
K
13
0159
QLAB QUANTIFICATION SOFTWARE HEART MODEL
K
13
0624
CONI
K
13
0770
MD211C3 21.3 DIAGNOSTIC IMAGING LCD MONITOR
K
13
0772
MD211C2 21.3 DIAGNOSTIC IMAGING LCD MONITOR
K
13
0929
ZMED VP4000
K
13
0884
XELERIS 3.1 PROCESSING AND REVIEW WORKSTATION
K
13
0383
SYNAPSE 3D CARDIAC TOOLS
K
13
0069
INNOVA EPVISION 2.0, INNOVA EPVISION 2.0
K
12
1916
INTUITION
K
13
0336
5MP MONOCHROME LCD MONITOR, RADIFORCE GX540
K
12
3976
NOBELCLINICIAN
K
13
0393
MIRADA RTX
K
13
0228
SUITEHEART
K
12
3186
RESOLUTIONMD MOBILE 3.1 MODEL RMD-MOB-31
K
13
0395
STEREOS WORKSTATION
K
12
3426
MEDICVOD, MEDICAST, MEDISHOW, MEDISEARCH, CENTRAL STORAGE SYSTEM - CSS
K
12
2578
VITREA CT TRANSCATHETER AORTIC VALVE REPLACMENT (TAVR) PLANNING
K
12
3650
ARIX RAD ACQUISITION CONSOLE
K
12
3575
MAMMOWORKSTATION
K
12
0851
COMMUNIFY PACS VIEWER
K
13
0103
CORONIS FUSION 6MP
K
13
0070
4MP COLOR LCD MONITOR, RADIFORCE RX440
K
12
3023
SURGERY REHEARSAL PLATFORM
K
12
3970
CAAS INTRAVASCULAR
K
12
3519
INVIVO DENTAL
K
12
3420
SYNGO, BREAST CARE
K
12
4048
IMAGEQUBE
K
12
3901
TRACTUS TISSUEMAPPER REVIEWER APPLICATION
K
12
3894
GE ECHOPAC
K
12
3269
PROCEDURE REHEARSAL STUDIO
K
12
3566
SYNAPSE 3D COLON ANALYSIS
K
12
3577
SYNGO.VIA MI WORKFLOWS
K
12
3920
SYNGO.VIA
K
12
1762
CARDIAC VX
K
12
3922
SYNGO DYNAMICS
K
12
3302
IB CLINIC
K
12
1296
INTERVENTIONAL WORKSPOT
K
12
3526
CLEARREAD +CONFIRM
K
12
3528
SCENIUM
K
12
3530
MAMMOGRAPHY PRIOR ENHANCEMENT (MPE)
K
12
0995
ERAD PACS/ERAD RIS/PACS/ERAD EPVLITE VIEWER SOFTWARE PRODUCT
K
12
2429
VESSEL ANALYSIS AND AUTOPLAQUE FOR ORS VISUAL
K
12
3375
SYNGO.VIA
K
12
3174
CENTRICITY PACS-IW WITH UNIVERSAL VIEWER
K
11
3344
STEREOS WORKSTATION
K
12
1213
VITREAADVANCED
K
12
1200
FLIGHTPLAN FOR LIVER
K
12
1781
ECHONAVIGATOR RELEASE 1
K
12
2289
IMAGE-COM 5.0
K
12
2523
CARESTREAM VUE PACS
K
12
1076
ULTRAEXTEND FX, ULTRASOUND WORKSTATION PACKAGE
K
12
2843
MD211G3 21.3 DIAGNOSTIC IMAGING LCD MONITOR
K
12
2022
ATHEROEDGE
K
11
1142
ECHOSOFT(TM)
K
12
0288
ORTHOCAD SOFTWARE OPTION
K
12
2427
CS ORTHODONTIC IMAGING SOFTWARE CS OMS IMAGING SOFTWARE
K
12
2260
AYCAN MOBILE
K
12
2164
MR VESSELLQ XPRESS
K
12
2136
VITREAVIEW
K
12
2329
BIOJET
K
12
2205
EXINI
K
12
0451
8MP COLOR LCD MONITOR, REDIFORCE RX840
K
12
0734
MICROSOFT AMALGA UIS IMAGE PROCESSING MODULE
K
12
1292
DYNAPBV BODY SOFTWARE
K
12
1075
NERVEVISION SOFTWARE SYSTEMS
K
12
1788
NIO 5MP
K
12
1517
VERSAVUE ENTERPRISE SUITE
K
11
3562
3MP COLOR LCD MONITOR, RADIFORCE RX340
K
11
3620
MYRIAN 1.11
K
12
1449
DIRECTPATH
K
12
0305
THINKINGNET, THINKINGPACS/RIS - PROPRIETARY NAME FRO THINKINGNET, THINKINGARCHIVE (OR NUPAX) - THE MANAGEMENT AND ARCHIV
K
12
0733
SIMPLANT GO
K
12
0636
SYNAPSE 3D CARDIAC TOOLS
K
12
0514
CARDIOPACS
K
12
1459
SYNGO.MR NEUROLOGY
K
12
0472
QUANTRA
K
11
3456
READY VIEW
K
12
0648
SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS
K
12
1074
SCENIUM 2.0
K
12
1387
CENTRICITY PACS-IW
K
12
0679
SYNAPSE 3D NODULE ANALYSIS
K
12
1466
GUIDEMIA
K
12
1023
SPECTRUM V.0
K
11
3739
SIMPLANT IMMEDIATE SMILE DENTAL CARE SYSTEM
K
12
1223
QLAB WITH FHN AND VPQ PLUG-IN
K
12
0637
SYNAPSE 3D BRAIN PERFUSION
K
11
3599
SURGICASE CONNECT
K
12
0207
VISIA
K
11
3240
3.7 MP COLOR LCD MONITOR, RADIFORCE MX270W
K
12
0718
INSTAPACS/INSTARISPACS
K
12
0407
2MP MONOCHROME LCD MONITOR, RADIFORCE GX240
K
12
0196
OLEA SPHERE
K
12
0076
RESOLUTIONMD WEB
K
12
0367
3MENSIO WORKSTATION
K
12
0315
SYNGO.MR SPECTRO ENGINE, SYNGO.MR SPECTRO SVS, SYNGO.MR SPECTRO CSI, SYNGO.MR SPECTRO EXTENSION
K
12
0161
ALPHAPOINT IMAGING SOFTWARE
K
12
0135
2D CARDIAC PERFORMANCE ANALYSIS MR 1.0
K
12
0709
THE DOME GX4MP COLOR NONITOR
K
12
0361
SYNAPSE 3D BASE TOOLS
K
12
0187
MULTI-MODALITY IMAGE FUSION
K
12
0221
GE ECHOPAC
K
12
0484
VISIA ONCOLOGY
K
12
0115
ORTHOSIZE
K
12
0525
QLAB QUANTIFICATION SOFTWARE
K
11
3082
SONOVISION
K
11
3784
3MP MONOCHROME LCD MONITOR, RADIFORCE GX340
K
11
3844
RADIFORCE RX240
K
11
2807
X-RAY VVA
K
11
2679
SIMPLANT NAVIGATOR PERSONALIZED DENTAL CARE SYSTEM
K
11
3701
VISIA NEURO
K
11
3442
3DI
K
11
3419
CS IMAGING
K
11
1758
CADENS (TM) COLON
K
11
3076
CAAS A-VALVE
K
11
2720
MCKESSON HORIZON CARDIOLOGY
K
11
1385
DELL ULTRASHARP U3011 W/QUBYX PERFECTLUM BUNDLE
K
11
2251
SWISSMEDA DENTAL PLANNING SYSTEM
K
11
2008
TOUCHPACS SUITE
K
11
1861
SYNGO.MR ONCO, SYNGO.MR 3D LESION SEGMENTATION, SYNGO.MR ONCO ENGINE
K
11
1776
DELTAVIEW MODEL 2.1
K
11
2387
PROCEDURE REHEARSAL STUDIO(TM)
K
11
3443
21.3 INCH (54 CM) MONOCHROME LCD MONITOR MS23I2 (ML21023)
K
11
3244
SYNAPSE MPR FUSION
K
11
2109
THE KINEGRAPH VMA SOFTWARE, THE MOTION NORMALIZER PATIENT HANDLING AND DATA COLLECTION DEVICE
K
11
3136
21.3INCH (54CM)COLOR LCD MONITOR CCL256I2(CL21256)
K
10
3554
METRON-CP/MD
K
11
3226
8MP COLOR LCD MONITOR,RADIFORCE RX840
K
11
3541
CLEARSTART SVM SYSTEM
K
11
3543
ONDEMAND3D
K
11
2480
VIEW 1 IMAGING
K
11
3404
DENTAL 3D PLANNING SOFTWARE
K
11
2930
MOBILE MIM
K
11
2570
CENTRICITY CARDIO IMAGING
K
11
2354
5MP MONOCHROME LCD MONITOR, RADIFORCE GX530
K
11
3029
SYNGO VIA MI WORKFLOWS
K
11
2531
VITREA CT MYOCARDIAL ANALYSIS
K
11
1642
ONCO TRAC MODEL 1, 2, 4
K
11
0596
MW100 (MAMMOGRAPHY) LCD MONITOR SYSTEM
K
11
2145
MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS33I2
K
11
1161
PERFSCAPE V2.0
K
11
0765
FXA (TM)
K
10
0784
UC-CARE NAVIGO SYTEM
K
11
2604
21.3 INCH (54 CM) COLOR LCD MONITOR CCL356I2 (CL21356)
K
11
2466
4MP COLOR LCD MONITOR, RADIFORCERX430
K
11
2974
PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
K
11
0919
CARESTREAM PACS
K
11
2439
SYNAPSE WORKSTATION SOFTWARE VERSION 3.3.0
K
11
1990
CORONIS 5MP
K
11
2051
LUNGPOINT PLANNING AND VIRTUAL BRONCHOSCOPIC NAVIGATION (VBN) SOFTWARE
K
11
2530
3DI INCLUDING CSCORE
K
11
2096
IMAGELINK
K
11
1019
SURGIMAP (TM) SPINE
K
11
1641
SURGICASE ORTHOGNATHIC SOFTWARE WIZARD
K
11
1496
21.3 INCH (54CM) MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR
K
11
1989
CORONIS FUSION 4MP DL
K
11
1833
VIRTUE
K
11
1731
MOLECULAR BREAST IMAGING SOFTWARE
K
11
1694
ASTRA
K
11
0033
FEEL-DRCS
K
10
1898
R4 ACERT ULTRASOUND REPORTING SYSTEM
K
11
1660
XELIS CARDIAC
K
11
1346
RESOLUTIONMD MOBILE MODEL RMB-MOB-2X
K
11
1613
XELIS FUSION
K
10
3308
AIDA HD CONNECT WITH SMARTSCREEN / BLU-RAY DRIVE / SMARTSCREEN WITH BLU-RAY DRIVE
K
10
3181
ZENIS, PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
K
11
1373
CT42 CARDIAC COMPUTED TOMOGRAPHY (CT) SOFTWARE
K
11
1991
NIO COLOR 2MP
K
10
2078
RADIOLOGICAL IMAGE PROCESSING SYSTEM
K
11
1945
IMPAX NEXT GENERATION
K
11
1319
IBIS EXPLORER AND MARKUP SOFTWARE
K
11
1245
HEARTNAVIGATOR RELEASE 1
K
11
1892
VITREAVIEW SOFTWARE 6.1
K
11
1804
INTELLISPACE PACS 4.X
K
11
1222
MRI-Q SYSTEM
K
10
3130
XELIS 3D
K
11
0797
COMMUNIFY PACS VIEWER
K
11
0300
SIMPLANT 2011
K
11
0886
CLIO/CLIOSOFT
K
11
1638
IMPAX VOLUME VIEWING
K
11
0414
QLAB 8.1 QUANTIFICATION SOFTWARE
K
11
1237
MD301C4 29.8 DIAGNOSTIC IMAGING LCD MONITOR, L309TY
K
10
3724
10 MP GRAYSCALE FLAT PANEL DISPLAY (GX 1030)
K
11
0447
ECHOINSIGHT
K
11
1336
EBW NM 2.0
K
10
2534
AZE VIRTUALPLACE-MR FLOW ANALYSIS SOFTWARE
K
11
1052
SYNGO NEURO PBV-IR
K
10
3723
SICAT IMPLANT V1.2
K
11
1079
SYNGO.VIA WEB VIEWER
K
11
0430
DOLPHIN IMAGING
K
11
1164
EUNITY
K
11
1102
RADIOVISION
K
11
0875
CENTRICITY PACS
K
11
0573
READY VIEW
K
11
0834
AW VOLUMESHARE 5 WITH ANGIOVIZ OPTION
K
11
1024
JETPACK 2.0
K
11
0139
CURVE IMAGE
K
11
0844
SYMBIA.NET
K
10
3565
MEDVOXEL HEARTPRO SOFTWARE APPLICATION
K
11
0667
IMAGE-ARENA AND IMAGE-ARENA APPLICATIONS
K
11
0595
4D SONO-SCAN 1.0
K
11
0186
SYNAPSE 3D LIVER ANALYSIS
K
11
0494
SYNGO MBF
K
11
0332
CLEARCANVAS RIS / PACS
K
10
3546
AYCAN WORKSTATION OSIRIX PRO
K
11
0108
MODALIXX
K
10
3720
SYNAPSE 3D LUNG AND ABDOMEN ANALYSIS
K
11
0511
E4D COMPASS
K
10
3480
THORACIC VCAR
K
10
3792
BARCO MAMMO TOMOSYNTHESIS
K
10
3687
SYNAPSE 3D CEREBRAL ANALYSIS
K
10
3458
VIEWPOINT 6
K
10
3679
AXIS PACS, HMS PACS
K
10
3576
MIM 5.2 (BRACHY)
K
10
3761
VISUALIZE: VASCULAR
K
10
3785
MOBILE MIM
K
10
1842
ACIES
K
10
1398
STEREOS WORKSTATION
K
10
3385
SECURVIEW DX DIAGNOSTIC WORKSTATION
K
11
0071
COR ANALYZER
K
10
3465
SYNAPSE 3D CARDIAC TOOLS
K
11
0077
NEUCOLONCARE
K
11
0040
OMNIVISION
K
10
3815
Q-STATION
K
10
3182
TRIANA, PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
K
10
3475
SPINEANALYER MODEL SAPOC
K
10
0372
SAFECT MODEL VER 1.0
K
10
0837
PACENTRIC CONNECT, TRAVELER AND WEB
K
10
2849
ACCULMAING
K
09
2728
20.1 INCH (51 CM) COLOR LCD MONITOR CCL208 (CDL2013A)
K
10
1654
IMPROVIS IMAGING SYSTEM
K
10
1707
FULACCESS MODEL 1.0
K
10
2435
BEYONDIMAGE WORKSTATION
K
10
2000
IMAGYS
K
10
2556
VOLPARA, VERSION 1.3
K
10
1166
4D-VIEW 9.1 (4D VIEW PC SOFTWARE) MODEL: H48651SZ
K
10
2150
SYNGO DYNAMICS, VERSION 9.0
K
10
1324
GE ECHOPAC MODEL BT10
K
10
2687
MIRADA RT
K
10
2684
XELIS DENTAL
K
10
1311
EP NAVIGATOR R3
K
10
1697
ENSITE VERISMO SEGMENTATION TOOL V.2.0
K
10
0793
UROSTATION 3D PROSTATE SUITE
K
10
1342
OSIRIX MD
K
09
3269
PROCEDURE REHEARSAL STUDIO
K
10
2148
CURIEPACS (DICOM PACS SOFTWARE)
K
10
1749
SYNGO TRUED SOFTWARE
K
09
0947
21.3 (54 CM) MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR, MODEL MS3112 (MDL2128A)
K
10
1666
SYNGO. PLAZA VA20A
K
10
1279
CORRIDOR4DM V2010 MODEL: V2010
K
10
1662
SYNAPSE 3D BASIC TOOLS
K
09
2328
MED-SEG, MODEL BTMS 1000
K
10
1796
PACSMATE MMD-5201M MONITOR
K
10
1228
MIRADA XD
K
09
3197
CORONIS FUSION 10MP, MODEL MDCG-10130
K
09
2915
CEDARA WEBACCESS, MODEL: 2.4
K
10
0619
SYMBIA.NET, SYMBIA.NET SELECT MODEL 10520828, 10520827
K
10
0292
CAAS QVA 3D, CAAS QCA 3D
K
09
4064
ILUMA VISION MODEL VERSION 2.2
K
10
0881
SYNAPSE OBLIQUUS MIP/MPR/FUSION
K
10
0335
ORS VISUAL
K
10
0236
STAIR SYSTEMS PACS & DICOM VIEWER
K
09
3603
STORM-BASE 2.0
K
09
2363
SOFTVIEW, MODEL 2.01
K
09
1631
ACCESSNET, ACCESSMED, ACCESSRAD, MEDVIEW
K
09
2427
SPINAL GUIDES PACS (PACS MEDICAL IMAGING DISPLAY WORKSTATION)
K
10
0094
CARESTREAM IMAGE SUITE
K
09
3480
CUATTRO UNOMD
K
09
0050
STEREOS WORKSTATION
K
09
3612
SYNGO.PLAZA
K
09
2613
COLOR LCD MONITOR, MODEL RADIFORCE RS210
K
09
2842
ECHOPLAQUE
K
09
3621
SYNGO.PET&CT ONCOLOGY
K
09
3444
EXAPACS
K
09
3703
3DI
K
09
3982
XELERIS 3 PROCESSING AND REVIEW WORKSTATION
K
09
3355
PCR ELEVA 1.2
K
09
3090
GALILEOS IMPLANT, VERSION 1.7
K
09
3672
AEGIS NAVIGATION ANDA EGIS PELVIC APPLICATION
K
09
3117
DIGITAL LIGHTBOX
K
09
1364
DICOMPACS, MODEL 5.2, DICOMPACS DX-R, MODEL 1.4
K
09
2125
PRESIDIO PACS
K
09
3247
MEDSYNAPSE PACS SOFTWARE
K
09
2639
INNOVA VISION, MODEL S18751VN, INNOVA TRACKVISION, MODEL S18751VT, INNOVA EPVISION, MODEL S18751EP
K
09
3423
LUNGPOINT PROCEDURE PLANNING
K
09
2741
COLOR LCD MONITOR, MODEL RADIFORCE MX241W
K
09
2954
CADSTREAM VERSION 5
K
09
3234
INTEGRATED REGISTRATION
K
09
2581
MITS DICOM GATEWAY AND IMAGE MANAGER
K
09
2949
IMAGEGRID RADIOLOGY VIEWER SYSTEM
K
09
2204
PMD VIEWER
K
09
2067
ABVS WORKPLACE
K
09
2134
STAT PACS PICTURE ARCHIVING & COMMUNICATION SYSTEM (PACS)
K
09
2519
SYNGO.X
K
09
2102
NORDICBRAINEX SOFTWARE, VERSION 1.0
K
09
2235
BEYONDIMAGE WORKSTATION
K
09
2081
QXLINK
K
09
1274
CORONIS 5MP HD, MODEL MDMG 5121
K
09
1687
PACSMATE, MODEL MMD-4300C/MMD-4300CX
K
08
3658
PACS PLUS 5TH EDITION
K
09
1262
MR CARDIAC FUNCTION ANALYSIS
K
09
1001
MYRIAN 1.4
K
09
0668
VISION TOOLS
K
08
3520
INTELEPACS, MODEL VERSION 3.X.X
K
09
1032
CERNER PROVISION WORKSTATION (VERSION 2.5)
K
09
0431
DEXIS SOFTWARE
K
09
0546
MODIFICATION TO NORDICICE SOFTWARE
K
09
1498
VITREA ENDOVASCULAR STENT PLANNING SOFTWARE
K
09
1368
R2 DIGITALNOW HD(DIGITALNOW HD)
K
09
0461
IMAGE-ARENA 4.0 AND IA APPLICATIONS 2D CARDIAC PERFORMANCE ANALYSIS 1.0
K
09
0155
CAAS MR FLOW 1.0
K
09
1373
SYNGO TRUED
K
08
3327
SYNGOCIRCULATION DYNAMICPET, VERSION 1.0
K
09
1286
SYNGO US WORKPLACE
K
09
0833
SEGMENT
K
09
1172
NIO 2MP (MDNG-2121)
K
09
1160
LUNGPOINT VIRTUAL BRONCHOSCOPIC NAVIGATION VBN SYSTEM
K
09
0607
BLUE SKY BIO PLAN, VERSION .38
K
09
0603
BARCO 5MP MAMMO, MODEL MDMG-5221
K
09
0732
NIO COLOR 3MP AND MDNC-3121
K
09
0218
MD213MC 21.3 DIAGNOSTIC IMAGING LCD MONITOR MODEL, L218TJ
K
09
0215
MD213MG 21.3 DIAGNOSTIC IMAGING LCD MONITOR - L218TL
K
08
3910
VIDISTAR PACS & DICOM VIEWER SOFTWARE SERVER SOFTWARE SYSTEM, HEART VIEW, STANDALONE VIEWER
K
09
0223
ICAD BREAST INTERVENTIONAL PLANNING SOFTWARE, MODEL D70024
K
08
3446
CARDIAC FUNCTION ANALYSIS, CALCIUM SCORING
K
09
0649
VRAD PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM SOFTWARE
K
08
1168
BRIT PACS SYSTEMS
K
09
0481
DEMASQ IMAGING SPFTWARE DEVICE
K
09
0552
UROCARE
K
09
0095
LUNGPOINT VIRTUAL BRONCHOSCOPIC NAVIGATION VBN SYSTEM
K
09
0295
BODYVIZ, MODEL 100
K
08
3182
DATACOM DC PACS
K
08
3691
BONEVUE
K
08
2623
VISIX IMAGING
K
08
2693
RESOLUTIONMD, RELEASE 2.1
K
08
3491
NEUROSCAPE
K
08
3740
MAMMODIAGNOST VU
K
09
0119
SICAT IMPLANT
K
08
1556
CADSTREAM, VERSION 5.0
K
09
0045
COLOR LCD MONITOR, RADIFORCE RX320
K
08
3618
PACS SCAN
K
08
3916
LCD3090WQXI OR MD304MC 29.8 INCH DIAGNOSTIC IMAGING LCD MONITOR, MODEL L307TD
K
08
3149
ARTERIAL HEALTH PACKAGE (AHP) SOFTWARE
K
08
3907
MD212MC 21.3 DIAGNOSTIC IMAGING LCD MONITOR-L217TG
K
08
3332
MD21M 21.3 DIAGNOSTIC IMAGING LCD MONITOR, MODEL L218TK
K
08
2808
IMAGESVR PACS
K
08
2526
CARDIO VUE QUANTITATIVE ANALYSIS (CVQ)
K
08
3673
CARESTREAM PACS, MODEL CARESTREAM PACS VII
K
08
3348
IMAGE-ARENA APPLICATIONS
K
08
3084
CT BRAIN PERFUSION FOR ZIOSTATION
K
08
3555
PICTURE ARCHIVING AND COMMUNICATION SYSTEM (PACS), PETAVISION
K
08
2269
VISAGE PACS, VERSION 6.0/CS 3.1
K
08
2607
MRI-PLAQUE VIEW, VERSION 1.1.2003
K
08
2441
NORDICICE SOFTWARE
K
08
2990
INFINITT XELIS
K
08
2628
CMR42 CARDIAC MRI IMAGING SYSTEM, 2.1.23
K
08
2240
SNTRYPACS
K
08
3018
CENTRICITY PACS WEB DIAGNOSTIC
K
08
2430
SYNGO IMAGING XS
K
08
2706
INFINITT CARDIOLOGY PACS
K
08
2493
MEDICAL DISPLAY, MD205MG-1
K
08
2135
SHOWCASE
K
08
2336
XR-EXPRESS
K
08
2684
4D VIEWER RADIOLOGY, MODEL USWP-100A
K
08
2663
COLOR LCD MONITOR
K
08
2510
IMAGE-ARENA APPLICATIONS, MODEL IMAGE-ARENA VA PLATFORM 1.0, 4D LV-ANALYSIS 2.5, 4D LV-ANALYSIS MR 1.0
K
08
1987
UNISYN IMAGE FUSION, VERSION 1.0
K
08
1985
AW SERVER
K
08
2596
ULTRAEXTEND USWS-900A
K
08
2228
PLANISIGHT LINASYS
K
08
1948
RAYPAX SYSTEM
K
08
1792
SPY ANALYSIS TOOLKIT, MODEL SA9000
K
08
2386
INREACH PLANNING LAPTOP
K
08
2483
QUANTRA
K
08
1945
21.3-INCH (54CM) MONOCHROME LCD MONITOR MS21I2 (MDL2127A)
K
08
1656
VISUALASE THERMAL THERAPY SYSTEM
K
08
2496
PACSMATE MMD-3213M MONITOR
K
08
2144
AMICAS PACS, VERSION 6.0
K
08
1357
5MP GRAYSCALE FLAT PANEL DISPLAY, MODEL, 6GF6201-5C$2# (WHERE $ = A-Z AND # = 0-9)
K
08
0196
Z3D CONTRAST ACUITY
K
08
2341
DSA 2000EX
K
08
0529
STEREOS WORKSTATION
K
08
1215
VOLUMINA
K
08
2318
CENTRICITY PACS IW
K
08
1672
C-INSIGHT
K
08
1752
EDGE PACS
K
08
2041
FIATLUX VISUALIZE
K
08
1630
MAMMO WORKSTATION
K
08
1976
IMPAX MA3000 DIAGNOSTIC PACS WORKSTATION
K
08
1512
STEALTHVIZ ADVANCED PLANNING APPLICATION WITH STEALTHDTI PACKAGE
K
08
1402
SIMPLANT ORTHO ; VISTADENT 3D
K
08
0905
QUANTUM/ CANON CXDI INTEGRATION SYSTEM, MODEL QG-DIG-CXDI
K
08
1843
ULTRASOUND DATA ANALYSIS SYSTEM, MODEL DAS-RS1
K
08
1734
SYNGO IMAGING (VERSION V31)
K
08
1076
VELOCITYAIS, VELOCITY AI, VELOCITYVX, VELOCITYRT, V-RESPONSE
K
08
1262
DC NEURO
K
08
1469
SECTRA WORKSTATION, IDS7 VERSION 11.3, IDS5 VERSION 11.1 P2
K
08
1304
ALZ WEB PACS, VERSION 1.0
K
08
1242
21.3 INCH (53CM) MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MS51I2, (MDL2123A)
K
08
1308
FUJIFILM FCR VIEW, MODEL CR-VW674
K
08
1056
21.3 (54CM) 3M COLOR LCD MONITOR CCL354I2 (CDL2126A)
K
08
1055
21.3 (54CM) 2M COLOR LCD MONITOR CCL254I2 (CDL2125A)
K
08
0951
19-INCH (48CM) 1.3M COLOR LCD MONITOR CDL1909A
K
08
0952
15-INCH (38 CM) COLOR LCD MONITOR CDL1576A
K
08
1347
ILUMA VISION
K
07
2258
BI-RADS COMPANION
K
08
1109
CORONIS 5MP MAMMO SL, MODEL MDMG 6121
K
08
1093
3-D IMAGING WORKSTATION
K
08
0890
SMARTSPOT PRIMAX
K
08
1018
SYNGO DYNAMICS VERSION 7.0
K
07
3358
LUMIMED SERIES 5MP DIGITAL FLAT PANEL DISPLAY SYSTEM, MODEL MM50/MM50A
K
08
0351
DEXELA DEX TOP MAMMOGRAPHY WORKSTATION, MODEL MAMWKVI
K
07
2728
SYNGO MULTIMODALITY WORKPLACE
K
08
0961
NM APPLICATION SUITE
K
08
0608
DIGITAL LIGHTBOX
K
07
3449
SURGICASE
K
08
0770
IMAGENMD WITH IMAGENQ
K
08
0325
IGROK
K
07
3468
MIMICS
K
08
0457
COLOR LCD MONITOR, MODEL RADIFORCE RX211
K
07
3714
TRAUMACAD VERSION 2.0
K
07
3176
KANTERON DICOM STATION (KDS), MODEL 3.0
K
07
3526
AMICAS VISION SERIES PACS, MODEL 5.5
K
08
0422
5 MEGAPIXEL MONOCHROME LCD MONITOR, MODEL RADIFORCE GS520
K
07
3062
OMNI-VUE SYSTEM
K
07
3418
SYNGO IMAGING CCF VA10A
K
08
0333
IMAGEGRID
K
08
0290
XVIEWNET
K
08
0334
INSTARAD
K
08
0320
PRIMEVUE 21 3MP COLOR DISPLAY, MODEL AC-QX21-A9300
K
07
3704
I-DIXEL
K
07
2821
VITREA 4DCT
K
07
3194
CMRTOOLS AND PLUG-INS VENTRICULAR TOOLS & THALASSAEMIA TOOLS
K
07
3007
CORONIS FUSION 6MP DL, MODEL: MDCC 6130 DL
K
07
1794
15M MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MDL2123A (MS51I2)
K
07
2653
3VISEON/SURGERY
K
07
2875
NIO 5MP DISPLAY, MODEL E5620
K
07
3292
MM/MMA/COLOR SERIES DIGITAL FLAT PANEL DISPLAY SYSTEM
K
08
0013
REGISTRATION AND FUSION
K
07
3169
SCIMAGE PICOMENTERPRISE
K
07
3306
XORANCONNECT
K
07
3448
MEDICAL DISPLAY, MD205MG
K
07
3259
XIDF-100A/B1 IMAGE PROCESSOR
K
07
3340
COLOR LCD MONITOR, FLEXSCAN MX300W
K
07
3205
NIO 5MP, MODEL MDNG-5121
K
07
3272
WORKSTATIONONE BREAST IMAGING WORKSTATION
K
07
2637
DIVO
K
07
3271
ORTHOGON
K
07
2986
INTEGRADWEB PACS SYSTEM
K
07
2952
GE ECHOPAC
K
07
2960
CDP 5000, MEDIA AND DISTRIBUTION CENTER, DIAGNET
K
07
2972
MEDSTREAMING MEDICAL OFFICE SOFTWARE
K
07
2532
TRUEPIX LCD MEDICAL DISPLAY MONITOR, MODELS TX-5M, TX-3M, TX-2M
K
07
2665
SUNIRAY 5.2
K
07
1964
MIM 4.1 (SEASTAR)
K
07
2242
COR ANALYZER II, MODEL V1.7
K
07
1584
OASIS RELEASE 1.0
K
07
2205
VISAGE PACS/CS, RELEASE VERSION 5.0
K
07
1492
FIRSTVIEW
K
07
1894
XEBRA DICOM IMAGE BROWSER
K
07
2065
20.8-INCH (53CM) COLOR LCD MONITOR CDL2119A (CCL352I2)
K
07
2066
1.3M MONOCHROME LCD MONITOR MDL1908A
K
07
1636
CODIAGNOSTIX (R) 5.72
K
06
3066
AXIS-V MONOCHROME 5 MP DISPLAY
K
07
1972
ORTHOPEDIC SOFTWARE FOR IMPAX WORKSTATIONS
K
07
1950
SYNGO TRUED
K
07
1602
IMAGIC V2.0
K
07
1166
UNIWEB, VERSION 5.0
K
07
1599
EASYGUIDE
K
07
1436
REGIUS UNITEA
K
06
2878
EZPACS, VERSION 3.0
K
07
1297
IMPAX SE SIGMACOM CLIENT (PACS WORKSTATION)
K
07
1232
IMAGE-ARENA APPLICATIONS AND RESEARCH-ARENA APPLICATIONS
K
07
1241
LMS-LIVER
K
07
1086
RESOLUTIONMD CARDIAC PRODUCT FAMILY, MODEL: RELEASE 1.0
K
07
1362
VITAL CONNECT 4.1
K
07
1331
VITREA VERSION 4.0
K
06
3269
5MP MEDICAL MONOCHROME REFERENCE DISPLAY, MODEL MDM2010-5NC
K
07
1114
SYNGO IMAGING (VERSION V30)
K
07
1054
RADIODEXTER, DEXTROSCOPE, DEXTROBEAM, MODELS 1.0, MK10, MK3 & MK4
K
07
0831
VOXAR 3D ENTERPRISE WITH COLONMETRIX AND PET/CT PERFUSION
K
07
0868
LMS-LUNG/TRACK
K
07
1000
MYRIAN
K
07
0755
INTERWORKS
K
07
0726
NIO COLOR 3MP AND MDNC 3120
K
07
0713
IMPLANT LOCATION SOFTWARE-T
K
06
3391
SAPHENEIA CLARITY
K
07
0618
DICOMPACS, MODEL 5
K
07
0606
VISIO+CD VIEWER# KPSCDVE01
K
07
0954
PATIENTGALLERY IMAGING SOFTWARE
K
07
0397
DGSCOPE, RELEASE 1.0
K
07
0683
MIRAGE CEDARS OPTION
K
07
0803
INVIVODENTAL
K
07
0796
CHILI PACS
K
07
0792
QLAB QUANTIFICATION
K
07
0394
CERNER PROVISION WORKSTATION
K
07
0205
ZIOSTATION
K
06
2621
NIO 5MP-21 AND MDNG-5121 CB
K
07
0464
ONDEMAND3D
K
07
0370
21.3 INCH (54CM) MONOCHROME LCD MONITOR MDL2122A
K
07
0226
CARDIOCT
K
07
0089
SYNTERMED LIVE
K
07
0248
VELOCITYAIS
K
07
0322
SYNGO DYNAMICS, VERSION 6.0
K
07
0131
RADIFORCE GX220 AND GS220 MONOCHROME LCD MONITORS
K
07
0244
AEGIS
K
07
0122
MONOCHROME LCD MONITOR, MODEL RADIFORCE GX320
K
06
3730
DEXTROSCOPE, MODEL MK10; DEXTROBEAM, MODEL MK3, MK4; RADIODEXTER, MODEL 1.0
K
06
3846
EIGEN DSA 2000
K
07
0080
INTELEPACS
K
06
3294
TOPACS
K
06
3548
COR ANALYZER 1, VERSION 1.4
K
06
3439
MEDICAL IMAGE MANAGEMENT DEVICES FOR VISION TOOLS
K
06
3539
NORDIC IMAGE CONTROL AND EVALUATION (NICE) SOFTWARE, VERSION 2.1
K
06
3826
SYNGO MI APPLICATIONS 2007A
K
06
3781
PHILIPS XD-S DIRECT RADIOGRAPHY WORKSTATION/PACKAGE
K
06
3470
AYCAN WORKSTATION OSIRIX
K
06
2905
NIO FUSION 4MP; MDNC 4130
K
06
3628
CENTRICITY RADIOLOGY RA600, CARDIOLOGY CA1000 AND DIGITAL HARDCOPY
K
06
3579
2MP MEDICAL COLOR REFERENCE DISPLAY, MODEL MDC2130-2HC
K
06
3505
VISUALASE ENVISION SOFTWARE SYSTEM
K
06
3392
IMCO-STAT
K
06
3337
OPAL-RAD
K
06
3253
RCHIVE PACS
K
06
3221
MEDWEB ADVANCED 3D WEB PACS
K
06
3200
20.1-INCH (51CM) COLOR LCD MONITOR CDL2010A (CCL204)
K
06
3153
NOVAPACS
K
06
3199
21.3-INCH (54CM) COLOR LCD MONITOR CDL2120A (CCL252I2)
K
06
3197
21.3 INCH (54CM) MONOCHROME LCD MONITOR MDL2118A (ME355I2)
K
06
3198
21.3-INCH (54CM) MONOCHROME LCD MONITOR MDL2121A (ME253I2)
K
06
3188
DEL-IMS
K
06
3344
CAAS QCA 3D
K
06
3327
ORTHOVIEW
K
06
2985
IVUS ENHANCER
K
06
2237
CADI, VERSION 4
K
06
2131
NIO 5MP-M-21 (NIO 5MP MAMMO); MDNG-5121 BB
K
06
3289
2MP MEDICAL MONOCHROME REFERENCE DISPLAY, MODEL MDM2130-2NC
K
06
1696
IQQA-LIVER SOFTWARE
K
06
3267
ISITE PACS, V 4. X
K
06
3266
3MP MEDICAL MONOCHROME REFERENCE DISPLAY, MODEL MDM2130-3NC
K
06
3120
COLOR LCD MONITOR, RADIFORCE, MODEL RX210
K
06
3093
SECTRA WORKSTATION, VERSION 11.1
K
06
2757
XERON PACS
K
06
3031
PRISM VIEW, MODEL
K
06
3006
GE LOGIQ WORKS
K
06
2743
UNISIGHT MAMMOGRAPHY VIEWER, MODEL 4.0
K
06
2598
IMT.LAB SOFTWARE
K
06
3107
3DNET SUITE
K
06
2490
VISAGE PACS/CS, RELEASE VERSION 4.1
K
06
2477
AMICAS VISION SERIES PACS, MODEL 4.3
K
06
0836
VISTADENT OC - VERSION 4
K
06
3037
CENTARISONE RIS/PACS
K
06
2054
5 MEGAPIXEL MONOCHROME LCD MONITOR, RADIFORCE GS510
K
06
2031
CHASE CARDIAC ANALYSIS SYSTEM
K
06
2163
MIMVIEWER
K
06
2164
RESOLUTIONMD, VERSION 1.3
K
06
2650
EP NAVIGATOR SOFTWARE
K
06
2488
IQ-SYSTEM PACS SYSTEM
K
06
1972
CONNECT IMAGING PACS
K
06
1532
GENTLE COLON (REVISION 2.0)
K
06
2229
CTC WORKSTATION, MODEL 2200
K
06
2062
VOYAGER PACS SYSTEM
K
06
2059
AIE REGION OF INTEREST IMAGE ENHANCEMENT
K
06
1995
XCELERA
K
06
1961
ART LAB SOFTWARE
K
06
1924
CORONIS 3MP AND MDCG 3120-CB
K
06
1927
CORONIS COLOR 3MP AND MDCC 3120-DL
K
06
1928
CORONIS COLOR 2MP AND MDCC 2121
K
06
2328
VITREAACCESS, VERSION 1.0
K
06
1920
NOVAPACS, NOVAVIEW, NOVACARDIO, NOVAQC AND NOVAER
K
06
2107
SECURVIEW DX DIAGNOSTIC WORKSTATION, MODELS SV-0001, SV-0002 AND SV-0003
K
06
1926
CORONIS 2MP AND MDCG 2121 - CB
K
06
2154
VITAL CONNECT 4.0
K
06
1855
NEUROQUANT
K
06
2053
MONOCHROME LCD MONITOR, RADIFORCE, GS320
K
06
1964
SYNGO MULTIMODALITY WORKPLACE
K
06
1947
21.3 INCH MONOCHROME LCD MONITOR
K
06
1421
ERAD PACS
K
06
1447
5M MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR MDL2116A (ME551I2)
K
06
1418
QUANTIVA
K
06
1672
SYNAPSE MIP/MPR IMAGE VISUALIZATION SOFTWARE OBLIQUUS
K
06
1671
SYNGO TRUED, MODEL VC10A
K
06
1624
VITREA, VERSION 3.9
K
06
1472
GALILEOS IMPLANT, V 1.0
K
06
1160
M-VU CAD STATION
K
06
1061
20.1-INCH (51CM) COLOR LCD MONITOR CDL2009A (CCL204)
K
06
1035
TIGERVIEW PROFESSIONAL
K
06
1396
QLAB QUANTIFICATION SOFTWARE
K
06
1372
CENTRICITY AW SUITE OPTION
K
06
1326
VOXAR 3D ENTERPRISE WITH CARDIAMETRIX
K
06
1303
MEDICAL DISPLAY, MODELS MDM 1900-1NG AND MDM 1900-1NR
K
06
1305
MEDICAL DISPLAY, MDC1900-1LG (1LR)
K
06
0950
3MATIC
K
06
0816
MIM 4.0 (NEURO
K
06
1214
AQUARIUSAPS SERVER
K
06
1126
ACCUREX
K
06
1029
JETSTREAM WORKSPACE
K
06
0961
15-INCH (38CM) COLOR LCD MONITOR CDL1566A
K
06
1018
PLANAR DOME EX LINE MODEL DOME E2C
K
06
0992
SYNGO US WORKPLACE
K
06
0845
MONOCHROME LCD MONITOR, RADIFORCE MODEL GS310
K
06
0941
CAAS MRV VERSION 3.0
K
06
0840
SVIEW
K
05
2424
MAXILIM
K
06
0505
VOXAR 3D ENTERPRISE, MODEL 6.1
K
06
0451
M-VU VIEWER STATION
K
06
0267
VIRTUAL IMPLANT PLACEMENT (VIP) DENTAL IMPLANT SURGERY PLANNING SOFTWARE
K
06
0263
IQPACS
K
06
0453
AZE VIRTUALPLACE
K
06
0378
VITREA2 VERSION 3.8.1
K
06
0035
MDXNET
K
05
3039
CLINTON ELECTRONICS SERIES II DIGITAL GRAYSCALE MONITORS, MODELS DL2000, DL3000, DL2000 OF AND DL3000 OF
K
05
3183
JIVE X SOFTWARE
K
06
0210
MEDIPORT
K
05
3592
SIMPLANT DR. JAMES
K
06
0055
KODAK PACS
K
05
3301
CEDARA I-RESPONSE CEDARA PET/CT
K
06
0136
PLANAR DOME EX SERIES DIGITAL FLAT-PANEL DISPLAY SYSTEM, MODEL E4C COLOR
K
05
3455
ENCOMPASS.NET
K
05
3347
KODAK CARESTREAM PACS
K
05
2988
CAAS
K
05
2942
21.3INCH MONOCHROME LCD MONITOR
K
05
3458
WEB1000
K
05
2467
BRAIN VIEWRX VIEWER, VERSION 1.0
K
05
2120
LUMIMED MONOCHROME LCD MONITOR, MODELS MM 20, MM 30 AND MM50
K
05
2632
VITREA2 VERSION 3.8 MEDICAL IMAGE PROCESSING SOFTWARE
K
05
3162
DEXTROSCOPE & DEXTROBEAM
K
05
3281
EVMS (ENTERPRISE VISUAL MEDICAL SYSTEM SOFTWARE)
K
05
3133
SYNGO DYNAMICS, VERSION 5.0
K
05
2963
MEDIQ VERSION 1.0
K
05
3155
VIMPLANT
K
05
3010
VISTADENT AT COMPLETE, MODEL 3.1
K
05
3043
ENCOMPASS SOFTWARE PACKAGE
K
05
2618
IMAGECAST PACS
K
05
2958
COLOR NIO 2MP, E-2320 C
K
05
2537
CATELLA DIAGNOSTIC WORKSTATION, VERSION 4.0
K
05
2995
ADVANTAGE WORKSTATION 4.3.
K
05
2545
INFINITT G3 PACS
K
05
2775
SYNGO MULTIMODALITY WORKPLACE (SYNGO MM WP)
K
05
2379
MIM 3.5 (CIRCA)
K
05
2895
FOURSIGHT VIEWTOOL IMAGE VIEWER
K
05
2284
REFORMAT GATEWAY
K
05
2312
WIDE 5MP (MAMMO) LCD MONITOR SYSTEM
K
05
2358
ETIAM STAR PACS COMPONENTS
K
05
2529
E-2320 PA S
K
05
2352
COLOR CORONIS 2MP-21 AND MFCD 2321
K
05
2478
MFCD 1219, MFCD 1219 TS
K
05
2461
SYNGO IMAGING VERSION V20A
K
05
2199
21.3-INCH(54 CM) MONOCHROME LCD MONITOR MDL2115A (ME353I), (DV3MM-HB), (ME353IM)
K
05
2460
POWERSERVER, POWERREADER, GATEWAY AND POWERCACHE
K
05
2411
HIPAX MEDICAL IMAGING SOFTWARE
K
05
2276
NIO 2MP-20 AND E-2620 S
K
05
2429
CORONIS 3MP-21 AND MFGD 3621
K
05
2403
CORONIS 2MP-21 AND MFGD 2621
K
05
2344
COLOR LCD MONITOR, MODEL RADIOFORCE R31 & R31-C
K
05
2337
MONOCHROME LCD MONITOR, MODEL RADIFORCE G33
K
05
2159
AIDA COMPACT II SYSTEM
K
05
1853
CARDIOSTREAM SONOAIM
K
05
1901
NIO 3MP-21
K
05
1840
ENSITE VERISMO SOFTWARE
K
05
1809
EASYVIZ, EASYVIZ SYSTEM, EASYVIZ PACS SYSTEM, EASYVIZ IMAGE AND DATA MANAGEMENT SYSTEM
K
05
1813
ULTRAPACS
K
05
1902
NIO 2MP-21
K
05
1586
VIEWSEND MEDICAL SYSTEM
K
05
1715
STARPACS DENTAL
K
05
1649
VERICIS CARDIOVASCULAR IMAGE AND INFORMATION SYSTEM, MODEL 4.0
K
05
1639
AS-OBGYN INFORMATION SYSTEM; AS-EMR SYSTEM
K
05
1743
R2 BREAST IMAGING WORKSTATION
K
05
0862
3TP WORKSPACE
K
05
1523
REGIUS CONSOLE CS-2000 AND REGIUS CONSOLE CS-3000, MEDICAL IMAGE PROCESSING WORKSTATION
K
05
1528
MEVIS LIVERANALYSER/LIVERVIEWER SOFTWARE
K
05
1673
XELERIS 2 PROCESSING AND REVIEW WORKSTATION
K
05
1745
ECHOSYSTEM
K
05
1403
19-INCH (48CM) COLOR LCD MONITOR CDL1904A
K
05
1553
FUJI SYNAPSE WORKSTATION SOFTWARE
K
05
1392
BTI-SCAN, VERSION 4.0
K
05
1521
REGIUS RS-1000, MEDICAL IMAGE PROCESSING WORKSTATION
K
05
1037
IMAGEQUBE PACS
K
05
1331
19-INCH (48 CM) COLOR LCD MONITOR CDL1902A
K
05
1325
WEBPAX, MODEL 200
K
05
1315
MODIFICATION TO: SECTRA IDS5 WORKSTATION
K
05
1127
KIKA IMAGING LAB VIEWER, MODEL 2.0.1.0
K
05
1201
E1 MEDICAL FLAT PANEL DISPLAY SYSTEM AND MFGD 1218 MEDICAL FLAT PANEL DISPLAY
K
05
0993
MMS VIDEO OPTION
K
05
0846
B-CAD SYSTEM, VERSION 1.0
K
05
0943
GE VIEWPOINT
K
05
1081
ESSENPACS
K
05
0736
IMORGON ULTRASOUND PACS SOLUTIONS
K
05
0619
20.8-INCH (53CM) COLOR LCD MONITOR, MODELS CDL2112A, CCL350I & DV3MC-HB
K
05
0617
21.3-INCH (54CM) MONOCHROME LCD MONITOR, MODELS MDL2109A, ME251I & DV2MM-HB
K
05
0751
IMPAX ORTHOPAEDIC WORKSTATION, MODEL IMPAX ES 5.X
K
05
0744
KAVO ERGOCOM/ERGOCAM
K
05
0703
QBRAIN
K
05
0616
21.3-INCH (54CM) COLOR LCD MONITOR, MODELS CDL2113A, CCL250I & DV2MC-HB
K
05
0485
20.8-INCH(53CM) MONOCHROME LCD MONITOR MDL2110A (ME351I), (DV3MM-HB)
K
05
0376
PROWIN
K
05
0667
R2 FAMILY OF IMAGE DISPLAY UNITS WITH R2 UNIFORM DISPLAY SOFTWARE
K
05
0341
IMPLANT LOCATION SOFTWARE, MODEL 0.1.0
K
05
0298
IPACS PRISM-5.0
K
05
0196
SECTRA IDS5 WORKSTATION
K
05
0228
AGFA HEARTLAB CARDIOVASCULAR
K
05
0033
LUCION
K
04
2755
MONOCHROME LCD MONITOR, RADIFORCE G51
K
04
3122
SMD 21500 OR DSB-2103-D-5MP-5M PIXEL GRAYSCALE FLAT PANEL DISPLAY
K
04
3483
RADIN, MODEL V 3.0
K
04
3430
20.8-INCH (53 CM) COLOR LCD MONITOR, MODELS CDL2114A AND DV3MC-HB
K
04
3415
CENTRICITY PACS SYSTEM
K
04
3194
VOXAR 3D PRODUCT FAMILY
K
04
3216
CADSTREAM VERSION 4.0
K
04
2868
MAMMOREPORT SOFTCOPY WORKSTATION
K
04
3360
IMT.LAB
K
04
3146
HORIZON MEDICAL IMAGING
K
04
2221
CORONIS 5MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
04
1078
SURGPLAN AND PANPLAN
K
04
3412
MODIFICATION TO: VIEWSTATION
K
04
3350
MISTAR, MODEL V3.2
K
04
3333
VITREA2, VERSION 3.7 MEDICAL IMAGE PROCESSING SYSTEM
K
04
3134
METRX WORKSTATION
K
04
2995
X-LEONARDO
K
04
2353
AXIS I (1MP), II (2MP), III (3MP), AND V (5MP) MONOCHROME DISPLAYS
K
04
2942
MGP 15 DICOM THEATER
K
04
2662
NIO 5MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
04
3097
3VISEON
K
04
2697
SECOND LOOK VIEWER
K
04
2661
NIO 3MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
04
2660
NIO 2MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
04
2816
TRAUMACAD 1.2
K
04
2700
IMAGE MEDICAL ACQUISITION STATION (IMAS)
K
04
2867
PHILIPS ORTHOPAEDIC APPLICATIONS
K
04
2832
SIENET COSMOS (VERSION V15A)
K
04
2212
IMPLANTMASTER
K
04
2383
RSA-CMS
K
04
2781
IPACS CARDIO
K
04
2634
WIDE 1MP LCD MONITOR SYSTEM
K
04
2692
CLARITY FUSION
K
04
2647
EXAM-PACS
K
04
2525
CENTRICITY RADIOLOGY RA600/CENTRICITY CARDIOLOGY CA1000/CENTRICITY DIGITAL HARDCOPY WORKSTATION
K
04
2507
UBIPACS
K
04
2334
ALLURA 3D-CA, RELEASE 1
K
04
2203
LEONARDO SYNGO CARDIOLOGY WORKSTATION
K
04
2042
ULTRASOUND CAPTURE SYSTEM
K
04
2311
PACSPARTNER
K
04
2313
INTEGRADWEB MPR/MIP
K
04
2292
ISITE PACS
K
04
2008
ULTRAVISUAL
K
04
1508
BARCOVIEW CORONIS 5MP HD MEDICAL FLAT PANEL DISPLAY SYSTEM
K
04
1935
DR SYSTEMS PACS, RELEASE 6.1
K
04
1782
SEEMOR 5.0 IMAGE DISPLAY PROGRAM
K
04
1555
SECURVIEW DX SOFTCOPY WORKSTATION
K
04
1990
FUJI MEDICAL CR CONSOLE, MODEL FLASH IIP
K
04
1484
UNDECIDED
K
04
0686
M'ATH STD
K
04
1682
CAAS MRV
K
04
1326
MEDCOMMONS OPEN RADIOLOGY GATEWAY
K
04
1162
ORTHO-CMS
K
04
0931
PATXFER RT
K
04
0896
MODIFICATION TO ENCOMPASS
K
04
1761
RAPIDIACOLON
K
04
1737
5M MONOCHROME DIGITAL MAMMOGRAPHY LCD MONITOR ME511L (MDL2105A)
K
04
1029
KINETDX
K
04
0970
LEONARDO
K
04
1597
MONOCHROME LCD MONITOR, MODEL RADIFORCE G22
K
04
1581
COMPACS, VERSION 1.0
K
04
1500
STARPACS ORTHOPEDICS SYSTEM
K
04
0310
NOVA FAMILY OF MEDICAL RADIOLOGY DISPLAYS
K
04
0443
DOME CX DIGITAL FLAT-PANEL DISPLAY SYSTEM, MODEL C5I
K
04
0697
21.3-INCH (54CM) COLOR LCD MONITOR CCL212 (CDL2107A)
K
04
1366
IPACS ORTHO
K
04
0746
MRA-CMS
K
04
0695
21,3-INCH (54CM) MONOCHROME LCD MONITOR ME213L (MDL2108A)
K
03
3859
BARCOVIEW MGD 521M DIGITAL MAMMOGRAPHY DISPLAY
K
04
1270
CT COLONOGRAPHY II
K
04
0555
IMPAX CLIENT EMBRACE
K
03
3849
SIMPLANT SYSTEM
K
04
0982
COLOR LCD MONITOR, MODEL RADIFORCE R12
K
04
0344
IMPAX OT3000 ORTHOPEDIC WORKSTATION
K
03
3912
CRADLE PACS
K
04
0376
SECTRA IDS5 RADIOLOGY WORKSTATION; SECTRA MPR PACKAGE; SECTRA 3D PACKAGE
K
04
0365
COLOR CORONIS 2MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
04
0546
IMAGE-ARENA AND RESEARCH-ARENA APPLICATIONS
K
04
0852
PREVIEW TREATMENT PLANNING SOFTWARE
K
04
0468
CEDARA I-SOFTVIEW AND CEDARA I-READMAMMO
K
03
3153
DICOM THEATER
K
03
1661
5M MEDICAL FLAT PANEL DISPLAY, ME511L
K
03
3006
MIVD 1218 18 INCH GREYSCALE LCD DISPLAY MODULE
K
04
0876
ICONNECTION, VERSION 3.2.0.0 MEDICAL IMAGE PROCESSING SOFTWARE
K
04
0126
VIATRONIX V3D COLON, REVISION 1.3
K
03
3104
MGD 2621P MEDICAL GREYSCALE DISPLAY
K
03
3005
MFGD 1318 18 INCH 1 MEGAPIXEL GREYSCALE LCD DISPLAY
K
03
3103
MGD 2621L MEDICAL GREYSCALE DISPLAY
K
03
3004
MFGD 2320 20 INCH 2 MEGAPIXEL GREYSCALE LCD DISPLAY
K
04
0158
MFCD 2320
K
04
0195
CALYSTO IMAGE IV-IMAGE AND INFORMATION MANAGEMENT SYSTEM
K
04
0399
QONTRAST
K
04
0041
NIO 3MP MEDICAL GRAYSCALE DISPLAY SYSTEM
K
04
0040
NIO 5MP MEDICAL GRAYSCALE DISPLAY SYSTEM
K
04
0050
INSTATRAK SYSTEM WITH MULTIPLE DATASET NAVIGATION, MODEL IT3500
K
04
0039
NIO 2MP MEDICAL GRAYSCALE DISPLAY SYSTEM
K
03
3955
RTIST
K
03
3920
CAAS II RVA
K
04
0486
MEDIPACS
K
03
4059
SECTRA ANGIOGRAPHY PACKAGE AND SECTRA CARDIOLOGY PACKAGE
K
03
2555
3M COLOR MEDICAL FLAT PANEL DISPLAY, CCL316
K
04
0305
VITREA2 VERSION 3.5
K
03
3466
COLOR LCD DISPLAY, MODEL RADIFORCE R22
K
04
0254
INTEGRIS 3D-RA, RELEASE 4.2
K
04
0227
QLAB QUANTIFICATION SOFTWARE
K
04
0142
ENSPHERE TEMPO JETSTREAM WORKSPACE CARDIOLOGY MODULE
K
03
3825
ORTHOPACS
K
03
2531
CHASE CARDIAC ANALYSIS SYSTEM
K
04
0028
CA-1500
K
03
3712
MODIFICATION TO SECTRA IDS5 RADIOLOGY WORKSTATION - VERSION 10.1
K
03
3831
SIENET COSMOS
K
03
3624
PACS SOFTWARE SOLUTION 2003
K
03
3400
SENO ADVANTAGE
K
03
1132
CONSULTIVA CASE INPUT STATION, MODEL CIS-1
K
03
3013
MDIFICATION TO MEDIPRIME
K
03
3361
VIATRONIX V3D VASCULAR, REVISION 1.0
K
03
3093
ECHOCONNEX COMMUNICATOR
K
03
1473
RATIONAL IMAGING PACS
K
03
3088
SECTRA IDS5 RADIOLOGY WORKSTATION VERSION 10.1
K
03
2748
VITREA2, VERSION 3.4 MEDICAL IMAGE PROCESSING SOFTWARE
K
03
2546
HOLOGIC DR IMAGEPRO
K
03
2533
INTELEPACS
K
03
2186
AUTOALIGN
K
03
2924
RADIODEXTER VERSION 1.0, DEXTROSCOPE, MODEL MK10 AND DEXTROBEAM, MODEL MK3
K
03
2960
WIDE 2MP TFT LCD MONITOR SYSTEM IF 1902A
K
03
2324
ECHOENCODER
K
03
1590
SECTRA ORTHOPEDIC PACKAGE
K
03
1567
3D INVIVO BY CSIST
K
03
2176
RATTAN IMACS BY RATTAN INFORMATION CORPORATION
K
03
2157
TELEMIS-MEDICAL SOLUTION
K
03
2760
APAX PACS SYSTEM
K
03
2638
DOME CX DIGITAL FLAT-PANEL DISPLAY SYSTEM MODEL, C3 COLOR AND C3 GRAY
K
03
2020
51CM(20.1INCH) TFT MONOCHROME LCD MONITOR, MU5111BW
K
03
2026
LCD MONITOR, RADIFORCE G11, G31, G51
K
03
2483
VIATRONIX V3D EXPLORER, REVISION 1.2
K
03
2401
ORTHOVIEW
K
03
1836
PHILIPS FRESCO RELEASE 1
K
03
1816
DVNET MDV-PACS
K
03
1562
RAMSOFT PACS, MODEL 3.0
K
03
1778
PRACTICEBUILDER 1-2-3
K
03
1779
CADSTREAM
K
03
2202
DOME CX DIGITAL FLAT-PANEL DISPLAY SYSTEM, MODELS C2 AND C5I
K
03
1704
FILMLESS CLINIC
K
03
2174
WIDE 3MP GRAYSCALE TFT LCD MONITOR IF2103A
K
03
1638
CARDIO VASCULAR INFORMATION ENHANCED WORKSTATION
K
03
2096
PHILIPS VIEWFORUM 2003
K
03
1929
5MP TFT LCD MONITOR SYSTEM IF2105A BY WIDE CORPORATION
K
03
1372
PERSONAL DIGITAL WORKSTATION (PDW); FILM DIGITIZING CAMERA AND DIGITAL WORKSTATION
K
03
1886
SONOVIEW PRO BY MEDISON CO., LTD.
K
03
1311
INTEGRADWEB BY DYNAMIC IMAGING, INC.
K
03
1248
CONSULTIVA REPORT STATION, MODEL RS-1
K
03
0781
KODAK DIRECTVIEW PACS/IMAGE MANAGEMENT SYSTEM, KODAK DIRECTVIEW WORKFLOW MANAGER,KODAK DIRECTVIEW CX/DX, KODAK DIRECTVIB
K
03
0751
IPACS PRISM
K
03
0728
FYRELINK VL
K
03
0347
20.1 MONOCHROME LCD MONITOR, RADIFORCE G20
K
03
0272
FLAT PANEL DISPLAY, ME183L
K
03
0276
FLAT PANEL DISPLAYS, CDL SERIES
K
03
0274
MEDICAL FLAT PANEL DISPLAY, ME315L
K
03
1013
INFINTT CO., LTD. STARPACS SYSTEM
K
03
0982
SYNGO COLONOGRAPHY SOFTWARE PACKAGE
K
03
0457
REX, VERSION 3.0
K
03
0635
THE OBSIDIAN PACS SYSTEM
K
03
0363
ORG@NIZER, MODEL VERSION 3.0
K
02
4358
20.1 MONOCHROME LCD MONITOR, RADIFORCE G21
K
03
0242
FYRELINK
K
02
4159
STRYKERWARE SYSTEM
K
03
0223
SONOCALC
K
02
2877
OBSERVER ULTRASOUND REPORTING AND IMAGING SYSTEM
K
02
4103
IVUS PLUS
K
02
4028
SHARP VIEW IMAGE ENHANCEMENT SYSTEM
K
02
3533
BARCO MEDIS 5MP2 AURA
K
02
4137
JUPITER PROCESSING AND REVIEW WORKSTATION
K
02
3460
PACSPLUS
K
02
3476
UNIPACS WORKSTATION
K
02
3467
HCP DICOM NET
K
02
3394
UNISIGHT SYSTEM WITH UNIGATE
K
02
3877
Q LAB QUANTIFICATION SOFTWARE WITH STRAIN RATE QUANTIFICATION PLUG-IN
K
02
3340
CORONIS 1MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
02
3339
IMAGETILE
K
02
3341
CORNIS 5MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
02
3322
CORONIS 2MP MEDICAL FLAT PANEL DISPLAY SYSTEM
K
02
3246
AMALGA PACS
K
02
3936
MODIFICATION TO MEDIPRIME
K
02
3137
PHILIPS EASYVISION WORKSTATION RELEASE 6
K
02
2773
BARCO MEDIS 2MP1NT MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
02
3772
KINETDX PICTURE ARCHIVING AND COMMUNICATIONS SYSTEM
K
02
2970
AMICAS LIGHT BEAM WORKSTATION, MODEL 1.0
K
02
3003
IMAGECHECKER-CT WORKSTATION
K
02
3557
CENTRICITY PACS PLUS
K
02
3440
PHILIPS DIGITAL IMAGING OPTION RELEASE 1
K
02
2938
VIZDEXTER VERSION 2.0; DEXTROSCOPE MK8; DEXTROBEAM MK3
K
02
2788
PHILIPS HARMONY RELEASE 1
K
02
3190
E.CAM COMPUTER / E.SOFT WORKSTATION
K
02
2881
CEDARA I-SOFTVIEW
K
02
2824
ECHO-VIEW 5.X, EASY-VIEW 2.X, OMNI VIEW 2.X, CARDIO-VIEW 1.X, LV ANALYSIS 1.X & SURGICAL VIEW 1.X
K
02
3100
ACCUSKETCH CARDIAC QUANTITATIVE SYSTEM W/ ADVANCED ANALYSIS COMPONENTS
K
02
2940
IN-VISION VIEW WITH MEASUREMENTS MODULE, MODEL 1.0
K
02
2710
SMARTPACS
K
02
2692
VOXELPLUS PACS
K
02
2585
KIMAX QMA
K
02
2896
CSV12 SOFTWARE VIEWER
K
02
2292
IMPAX DIAGNOSTIC DISPLAY STATION,IMPAX CLINICAL REVIEW STATION,IMPAX FOR CARDIOLOGY CLINICAL REVIEW SATATION,IMPAX ORTHO
K
02
2789
VIATRONIX V3D EXPLORER
K
02
1913
CALSCOR SOFTWARE
K
02
1738
FLAT PANEL DISPLAYS, ME SERIES & CCL SERIES
K
02
1934
MODIFICATION TO MEDSTATION
K
02
1583
PATXFER
K
02
2428
QUANTITATIVE BLOOD POOL SPECT (QBS)
K
02
2310
ADVANTAGE WINDOWS X-RAY/MR FUSION
K
02
1236
SURGERY AND ACCESSORIES
K
02
2109
EIZO, MODEL FC-2091
K
02
1191
AUTOALIGN
K
02
0073
MEDICAL ADMINISTRATOR
K
02
1966
Q LAB SOFTWARE
K
02
1314
SCEPTRE-VS
K
02
1099
REX, VERSION 1.0
K
02
1072
FILMSAVER, NT VERSION 5.03
K
02
1669
PHYSICIAN'S DESKTOP REVIEW
K
02
0449
CARDIONOW CARDIOLOGY WIDE AREA ARCHIVE AND RETRIEVAL SYSTEM
K
02
0546
FUSION 7D
K
02
0995
EFILM WORKSTATION WITH MODULES
K
02
0058
MEDICAL LE
K
02
0059
MFCD 118I
K
02
0061
IMAGEDESK
K
02
0658
VIATRONIX V3D COLON
K
02
0483
ADVANTAGE WORKSTATION 4.1
K
01
2439
DENTALEYE 2 DENTAL IMAGE MANAGEMENT SYSTEM
K
01
3994
MODIFICATION TO VIEWSEND MEDICAL
K
02
0140
VOXAR'S CALCIUM SCORING PRODUCT
K
01
3922
CORONIS 3MP MEDICL FLAT PANEL DISPLAY SYSTEM
K
01
3841
3DFIS, MODEL IES-FL-101
K
01
3574
ACCENT
K
01
4058
ENTEGRA PE PERSONAL DIGITAL ASSISTANT
K
01
3419
NICOLET ELECTROMAGNETIC NAVIGATION SYSTEM
K
01
2327
CSIST DICOM GATEWAY/IMAGE MANAGER
K
01
3878
CYBERMED, INC., V-WORKS
K
01
3098
KIMAX REMOTE VIEWING STATION
K
01
3630
ISITE RADIOLOGY
K
01
2844
MAROSIS PACS
K
01
1196
IQUANTIFY, VERSION 1.0
K
01
2779
ICONNECTION 3D
K
01
2563
DEEP GRAY
K
01
2475
CAAS II QVA
K
01
2290
RAPIDIA
K
01
2093
AETMED IMAGE PROCESSING SOFTWARE
K
01
2086
AQUARIUSNET SERVER
K
01
1694
VIEWSTATION
K
01
2155
KODAK RADIATION ONCOLOGY SOFTWARE/ FOR ACR SYSTEMS
K
01
2211
EFILM WORKSTATION
K
01
2099
MONOCHROME PERFECTLY FLAT PANEL DISPLAYS, ME SERIES
K
01
1582
QCU ANALYTICAL SOFTWARE PACKAGE
K
01
2097
VORTEX
K
01
2072
VOXAR VC, MODEL 1.0
K
01
1173
TELEPAX
K
01
0938
SYNGO MULTIMODALITY WORKSTATION
K
00
2911
XSCAN32 TELERADIOLOGY SOFTWARE
K
01
0763
GOODNET
K
01
1142
AQUARIUS WORKSTATION
K
01
0726
MODIFICATION TO MIRAGE
K
01
0259
MEDIFACE PACS
K
01
0271
THINKINGNET
K
01
0571
ADC QS/IPD WORKSTATION
K
01
0058
IMAGE IV DICOM IMAGE ARCHIVAL PACS NETWORK
K
00
2789
MEDEVIEW SYSTEM
K
00
3746
3D-DOCTOR
K
00
3762
ALI 3D TOOL MODULE FOR MEDICAL IMAGES
K
01
0336
ADVANTAGE WINDOWS CT/PET FUSION
K
00
3607
ONYX-RAD TELEMEDICINE PACS
K
00
3510
INSTATRAK SYSTEM WITH FLUOROCAT, MODEL IT3500
K
00
3437
ODYSSEY LX, MODEL 211320
K
00
3688
VIEW READING STATION
K
00
3459
PHILIPS EASY VISION FAMILY WORKSTATION OPTION MR QUANTITATIVE FLOW
K
00
3484
NETRA WORKSTATION AND NETRAMD SOFTWARE
K
00
2942
PHILIPS EASY VISION FAMILY WORKSTATION OPTION CARDIRAC SCORING
K
00
1550
EBT ULTRAFAST CT SCANNER SYSTEM; C-100, C-150, C-150LXP OR C-150XP SCANNER SYSTEMS; ELECTRON BEAM SCANNER SYSTEM; ELECTR
K
00
2894
MEDIPRIME
K
00
2782
HERMES HD AQ ACQUISITION STATION AND HERMES WORKSTATION
K
00
1947
T.I.M.S., VERSION 2.00
K
00
2780
VIATRONIX VISUALIZATION SYSTEM (VVS)
K
00
2724
NUMALINK
K
00
2597
CN ACQUISITION STATION
K
00
2590
CEDARA CARDIOLOGY VIEWER, CARDIOLOGY ARCHIVE VIEWER, CARDIOLOGY CD VIEWER
K
00
2424
3D ANGIOGRAPHIC IMAGING SYSTEM, MODEL XIDF-100A
K
00
2519
VITREA 2, VERSION 2.1
K
00
2936
MODIFICATION TO IDS5 IMAGE DISPLAY SYSTEM
K
00
2144
MEDLINK DIAGNOSTIC OFFLINE WORKSTATION
K
00
2039
ECAT PET SCANNER, MODELS ECAT EXACT AND ECAT EXACT HR+ AND ECAT ART
K
00
2100
XIMX SYSTEM
K
00
1753
MEDIS 5MP2 DUAL-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1748
MEDIS 5MP2 QUAD-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1750
MEDIS 5MP1H QUAD-HEAD MEDICIAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1752
MEDIS 55MP1H SINGLE-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1754
MEDIS 5MP1H DUAL-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1751
MEDIS 2MP2 QUAD-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1747
MEDIS 2MP2 DUAL-HEAD MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
00
1596
LIFERX
K
00
1012
DIGITAL INTEGRATION SYSTEM, DIS2000
K
00
0770
PROVIEW MEDICAL IMAGE DISPLAY MODULE
K
00
0630
MODELS PRIAM (FAMILY OF DEVICES) DIGITAL IMAGING SYSTEM
K
00
1140
IDS5 IMAGE DISPLAY SYSTEM
K
00
0395
EINSTEIN PROCESSING AND REVIEW WORKSTATION
K
00
0380
FOTOMASTER
K
00
0557
MEDVIZER PACS, MODEL RELEASE 2000
K
00
0443
REMOTE FETAL MEDICINE ULTRASOUND SYSTEM
K
00
0448
PACSSTATION
K
00
0474
VIEW NT
K
00
0293
BARCO MGD 221 2 MEGAPIXEL DIAGNOSTIC DISPLAY
K
00
0292
BARCO MWD 321 PLUS MEDICAL WORKSTATION DISPLAY
K
00
0294
MFCD 120
K
00
0291
MFCD 118
K
00
0014
BARCOMED 5MP1H
K
00
0016
BARCOMED 5MP2
K
99
4270
INSTATRAK 3000 SYSTEM WITH FLUOROTRAK MODULE, MODEL IT3000
K
99
3946
PEGASYS ULTRA
K
99
4228
REMOTEIMAGE SYSTEM
K
99
4054
ISSA PHAROS
K
00
0015
BARCOMED 2MP2
K
99
4210
INTURIS SUITE
K
99
3750
PROSOLV ECHOVIEWER, PROSOLV ECHOVIEWER SE, PROSOLV ECHOANALYZER, PROSOLV ECHOSERV, PROSOLV ECHO
K
99
3802
SHARPVIEW IMAGE ENHANCEMENT SYSTEM
K
99
3338
INTEGRATED DIGITAL MEDICAL RECORD (IDMR)
K
99
3283
OSCAR NET/CD, MODEL M1.82 600 . O/A/B/C
K
99
3761
CARDIOVASCULAR MEASUREMENT SYSTEM - VIEW
K
99
3227
PHILIPS INTURIS DICOM RECORDER
K
99
3532
DDS, DS3000, RS3000, CS5000, OT3000, IS3000, RS5000, CD3000, US3000, (AMONGST OTHER NAMES)
K
99
3530
SYSTEM 2100
K
99
2925
AX WORKSTATION DR-VIEWER SOFTWARE OPTION
K
99
2886
POWERVIEW ULTRASOUND WORKSTATION, UIDM-400A
K
99
2654
PLUG 'N VIEW 3D, VERSION 1.0
K
99
2666
VIDEO PLUS SYSTEM, SERIES 95000
K
99
2354
SNT IMAGE ANALYSIS SYSTEM
K
99
2575
CARDIOVASCULAR WORKSTATION, MODEL CWS 5000/CWS 3000
K
99
0241
ACCUIMAGE, ACCUVIEW DIAGNOSTIC IMAGING, WORKSTATION W/ACCUSCORE, ACCUANALYZE, ACCUSCOPE, ACCUSHADE, ACCUVRT, AND ACCUMIP
K
99
2306
SAMSUNG RAYPAX DISPLAY WORKSTATION
K
99
2112
SAMSUNG RAYPAX FILM DIGITIZER
K
99
2073
AX WORKSTATION
K
99
2259
ECHOCARDIOGRAPHY SYSTEM SERIES 95000
K
99
1738
DIGITAL VIDEO RECORDING SYSTEM
K
99
1629
GE VIEW APPLICATIONS (CONSISTING OF GE VIEWING STATION AND GE EXTENDED VIEWING STATION) VERSION 1.2C
K
99
1468
IMMERGE IMAGE CORRELATION
K
99
1626
WEBRAD COMPUTED RADIOGRAPHY QUALITY ASSURANCE WORKSTATION
K
99
1257
FUJI WAVELET COMPRESSION OR FFCOMP IRREVERSIBLE COMPRESSION
K
99
1643
IDS4 V3.2 IMAGE DISPLAY SYSTEM
K
99
1578
SMARTSPOT 2000
K
99
0455
PHILIPS EASY VISION FAMILY WORKSTATION LEGS OPTION
K
99
0442
ADVANCED DIAGNOSTIC VIEWER (AOX), MODEL VITRED 1.3
K
99
0919
STRAIGHT ASPIRATOR, 90 DEGREE ASPIRATOR,45 DEGREE ASPIRATOR,7 FRENCH ASPIRATOR,EXTENDED STRAIGHT ASPIRATOR,13.9 CM STRAG
K
99
0759
VIEW COM
K
99
0052
TEL-ECHO SYSTEM
K
98
4215
WELCH ALLYN FRONT-LINE DOC
K
98
3815
PACSCACHE
K
98
3529
INSTATRAK 3000
K
98
2535
INSIGHT DIAGNOSTIC IMAGING WORKSTATION
K
98
3401
FRAMEWAVE WEB
K
98
3392
DATA RAY CORPORATION DR11021 MEDICAL IMAGING MONITOR
K
98
3256
ADVANTAGE WINDOWS (AW) FUSION
K
98
3821
PHILIPS INTURIS CARDIO IMAGE VIEWING PACKAGE
K
98
4023
MAXVIEW DIAGNOSTIC WORKSTATION
K
98
2976
ULTRASOUND WORKSTATION, UIWS-300A
K
98
3111
XRAY VISION
K
98
2994
SKULL BASE INSTATRAK SYSTEM
K
98
2769
MITRA IMAGING INC. EXHIBIT
K
98
2862
RADWORKS MEDICAL IMAGING SOFTWARE WITH QUALITY CONTROL MODULE
K
98
2820
BARCO MEDIS 5MP 5 MEGAPIXEL MEDICAL DIAGNOSTIC DISPLAY SYSTEM
K
98
2690
BARCO MEDICAL DISPLAY CONFORMITY AND CONSISTENCY SOFTWARE
K
98
2563
ULTRAPRO MODEL 98
K
98
2422
EAGLESOFT CHAIRSIDE
K
98
3088
INSTACINE D-2000
K
98
2146
PICTOOLS MEDICAL TOOL KIT MODEL 1.0
K
98
2120
DIGITAL IMAGING SYSTEM, MODELS DIGITREX-1000 AND DIGITREX-2000 (DIGITREX-X000 FAMILY)
K
98
1998
PEDIATRIC INSTATRAK SYSTEM
K
98
0648
PRO VISION
K
98
1217
PLATINUM READING, REVIEW & ANALYSIS WORKSTATION
K
98
0234
THE NETWORK SYSTEM
K
98
0970
IIRAD DIRECTRAY OPERATOR CONSOLE
K
98
0168
COMPUTED RADIOGRAPHY QUALITY ASSURANCE SOFTWARE
K
98
0118
KODAK DIGITAL SCIENCE ONCOLOGY IMAGE MANAGER
K
97
4755
DYNA VUE 3-D IMAGING PRODUCT
K
97
4504
EPS
K
98
0060
ECHOLINK
K
97
4474
PEGASYS INTOUCH
K
97
1965
PHILIPS EASYVISION
K
97
4134
X-SIGHT DIGITAL IMAGING SYSTEM
K
97
4207
PHILIPS EASYVISION WORKSTATION
K
97
4086
KODAK DIGITAL SCIENCE CARDIAC VIEWER
K
97
3983
PHILLIPS EASY VISION FAMILY WORKSTATION OPTION ENDO 3D
K
97
3835
PHILIPS EASYVISION WORKSTATION
K
97
3653
SEEMOR - DISPLAY & PROCESSING PROGRAM EXECUTING ON PERSONAL COMPUTER SYSTEM
K
97
3148
MACOM
K
97
2215
MEDIMAGE
K
97
3065
REALVIEW TELEMEDICINE SYSTEM
K
97
3010
REALTIME 3D DIAGNOSTIC WORKSTATION
K
97
3081
DIGITIZER DIRECTOR: IMAGE COMPRESSION MODULE (HO4059-REV 2.0)
K
97
2933
VOX/BASE FOR WINDOWS
K
97
2886
MIRAGE
K
97
2520
OPTIVIEW
K
97
2256
FCR FUJI COMPUTED RADIOGRAPHY DMS CRT IMAGE CONSOLE HI-C654 (FOR NETWORKS)
K
97
2103
PHILIPS EASYVISION
K
97
1973
KODAK DIGITAL SCIENCE PRO-MEDICAL THERMAL PRINTER
K
97
1776
ECHOVACS
K
96
5179
INSIGHT DIAGNOSTIC IMAGING WORKSTATION NIT-DU0-ZOO
K
97
1368
IDS4 IMAGE DISPLAY SYSTEM SERIES
K
97
1714
NDC DENTAL SYSTEM, VERSION 1.5 X-RAY AND VIDEO
K
97
1290
STRATASYS FDM MEDMODELER SYSTEM
K
97
0964
MAESTRO DIGITAL IMAGE AND PATIENT RECORD STORAGE SYSTEM
K
97
0813
DIMS (DIGITAL IMAGING AND MEDICAL SYSTEM) CL1-5110/5111
K
97
0623
IMMERGE IMAGE CORRELATION
K
97
0617
CT-MODELLER SYSTEM
K
97
0451
DOWNSCAN 120
K
97
0534
PICTURE ARCHIVING & COMMUNICATIONS DEVICE
K
97
0450
UPSCAN 120
K
97
0349
FUJI MEDICAL LASER IMAGER MF PRINT SERVER MF-PS667
K
97
0402
DOCTORS REVIEW SYSTEM
K
96
2010
EPI-SCOPE OPTION FOR Q SERIES CT SYSTEMS
K
96
4327
IPU RX-2
K
96
2153
DIGITAL IMAGE ANALYSIS SYSTEM
K
96
3980
PHILIPS EASYVISION
K
96
4124
PHILIPS COMPUTED RADIOGRAPHY
K
96
3859
QLVA PLUS
K
96
3697
ADVANCED DIAGNOSTIC VIEWER (ADV)
K
96
3610
AKI COMPACS DATA COMPRESION MODULE FOR DIAGNOSTIC IMAGES
K
96
1740
KODAK DIGITAL SCIENCE MEDICAL PRINTER INTERFACE UNIT
K
96
1739
KODAK DIGITAL SCIENCE MEDICAL MODALITY ACQUISITION UNIT
K
96
3037
PATRIOT
K
96
2589
AURORA DIAGNOSTIC WORKSTATION
K
96
2260
REAL-TIME VIDEO CONTRAST ENHANCER
K
96
1983
TRS 2000 TELERADIOLOGY SYSTEM
K
96
1871
FLOUROSPOT T.O.P.
K
96
1637
PICKER MR WORKSTATIONS (VISTAR,MONTAGE AND ONCALL)
K
96
1403
LIFE IMAGING SYSTEMS LIS 6000 A
K
96
0265
ADVANTAGE WINDOWS WITH FUNCTOOL OPTION
K
96
1307
SMART SPOT
K
95
3911
PHILIPS EASYVISION
K
95
5457
DIGISCAN 2 PLUS
K
95
5092
ACCURAD IMAGE MANAGEMENT SYSTEM, AUTORAD, REGUSTRATION STATION, ARCHIVE SERVER, PRINT SPOOLER, ANALOG & DIGITAL ACQUIRE
K
96
0946
ECHONET
K
96
0665
ECHO-COM FOR MS-WINDOWS VERSION 2.0
K
96
0613
GE ADVANTAGE WINDOWS REVIEW WORKSTATION
K
96
0071
IMAGEFUSION
K
96
0330
INSTATRAK
K
96
0043
KODAK CARDIOLOGY DIGITAL ARCHIVE & REVIEW SYSTEM
K
95
4159
DIGITAL IMAGING SYSTEM
K
95
3616
PREVIEW SURGERY PLANNING SOFTWARE
K
95
4678
PRO VISION
K
95
4589
CLARK TUT IMAGE PROCESSING SYSTEM
K
95
5185
GE ADVANTAGE DICOM CR REPROCESSING STATION
K
95
4860
ECHONET
K
94
4612
ACUSTAR I ADVANCED SURGICAL NAVIGATION SYSTEM
K
95
4222
VIDEO ENHANCEMENT UNIT
K
95
4211
CRISPICS
K
95
3259
VOXELVIEW
K
95
4668
HP ECHO IMAGE MANAGEMENT SYSTEM
K
95
3095
PHILIPS EASYVISION
K
95
1262
OPERATING ARM SYSTEM (OAS)
K
95
4055
HDX DIGITAL IMAGING SYSTEM
K
95
2862
FUJI COMPUTED RADIOGRAPHY SYSTEM FCR9501ES.FCR
K
95
2778
CHESHIRE
K
95
2313
VARIS IMAGES, INCLUDING XIMATRON DIGITAL IMAGING OPTION
K
95
3164
ALALYSIS PACKAGE FOR DENTAL APPLICATIONS FOR XPEED, XPRESS, XVISION
K
94
5807
HOMEVUE WOUND MONITORING SYSTEM
K
94
5188
CEMAX VIPSTATION AND/OR SOFTWARE
K
94
1566
COMPUSPEAK
K
94
5582
WITT BIOMEDICAL IMAGE III
K
94
2504
INSTASPOT
K
94
5428
SCRIBE(TM) DIAGNOSTIC IMAGING WORKSTATION
K
94
6117
MEDICAL IMAGE MANAGEMENT SYSTEM (MIM)
K
94
5389
IVR MASTER
K
92
5963
IMAGE TRANSPORT SERIES II
K
94
5388
DFS-700
K
93
4572
UNITONE
K
94
0664
PAPER FILM
K
94
1093
SMARTPACS FILMLESS READING AND IMAGE DISTRIBUTION SYSTEM AND CONSULTATION STATION
K
93
6179
WINRAD TELERADIOLOGY SYSTEM
K
94
1933
ISG MEDICAL IMAGING FAMILY OF WORKSTATIONS (MIFW)
K
91
1783
ALLEGRO VIEWING WAND
K
93
2564
RADSTAT
K
93
5694
SIENET DIAGNOSTIC REPORTING CONSOLE VA02 UPGRADE
K
93
2371
CEMAX CLINICALVIEW(TM) STATION AND/OR SOFTWARE
K
93
2372
CEMAX VIPSTATION(TM) AND/OR SOFTWARE
K
93
3209
VISIONTOOL
K
93
1376
GAMMACON IMAGE TRANSLATION SYSTEM
K
92
5664
SERIES V-SCAN RADIOGRAPHIC FILM SCANNER
K
93
0527
DENTAL LINK
K
92
0851
MACVIEW
K
92
4630
SURGICAD(TM) VIEW(TM)
K
92
4366
PERSONAL DISPLAY SYSTEM
K
92
5793
TELESHARE 910
K
92
2267
PHOTOPHONE(R) MULTI VIEW(TM)
K
92
5465
TELERADIOLOGY DEVICE & COMPONENT OF PACS COMPONENT
K
92
4310
PRESTILIX 1694 D IMAGE INTENSIFIED FLUOROSCCOPIC
K
92
3042
DU PONT LINX HD-25 LASR IMAGER
K
92
3913
NOISE REDUCTION UNIT W/ LAST IMAGE HOLD
K
92
0319
SIENET IMAGE DISPLAY WORKSTATIONS, IMAGE ACQUISITI
K
92
3270
KODAK EKTASCAN IMAGELINK QUALITY CONTROL WORKSTATI
K
92
1484
MEDVISION
K
92
2310
VORTECH'S PERSONAL DISPLAY SYSTEM
K
91
5342
UD 2000 VIDEO OPTION
K
92
0950
PHILIPS EASYVISION
K
92
0309
SIENET DIAGNOSTIC REPORTING CONSOLE
K
91
4366
MEDRAD PATHFINDER HR ROADMAPPING SYSTEM
K
91
5305
OPTION U1 FOR THE DPS-PLUS SYSTEM
K
91
5542
QCA PLUS
K
91
5237
PHILIPS PCR-ACE SYSTEM
K
91
3755
STATVIEW
K
91
3264
HYDRAVIEW 1000 DIGITAL IMAGE PROCESS/STOR DEVICE
K
91
3754
CARDIO 500
K
91
2829
CARDIOTRACE CARDIAC EVALUATION SYSTEMS
K
91
1752
ICON TELERADIOLOGY SYSTEM
K
90
4519
AGFA DIAGNOSTIC CENTER (ADC)
K
91
0437
FUJI COMPUTED RADIOGRAPHY SYSTEM FCR 7501
K
90
5132
SHIMADZU IMAGE PROCESSOR DFS-500
K
90
5801
CEMAX SPARCSTATION IMAGING SOFTWARE AND WORKSTATIO
K
90
5222
CEDARS-SINAI QUANTITATIVE TI-201 ANALYSIS CTQ 2.0
K
90
2428
INTEGRATED DIAGNOSTIC SYSTEM W/ADD'L OPTIONS
K
90
4590
KODAK EKTASCAN LASER PRINTER, MODEL 100 XLP
K
90
1422
SCIVIEW SYSTEM, MODEL SC1250 AND PIXIE IMAGING SOF
K
90
2648
PINNACLE IMAGE PROCESSING SYSTEM
K
90
3196
IMAGE INTENSIFIED FLUOROSCOPIC X-RAY SYSTEM
K
90
1679
RESUBMITTED ISG 3DMV WORKSTATION
K
90
0851
DIGITAL IMAGE ENHANCEMENT SYSTEM
K
90
0697
CEDARS-SINAI QUANTITATIVE THALLIUM-201 ANALYSIS
K
90
1158
LITEBOX DIAGNOSTIC REVIEW WORKSTATION
K
89
7000
IMAGEMASTER-101(TM)
K
90
0586
MEDRAD FLUOROVISION HR 2000, HIGH RESOLUTION IMAGE
K
89
6050
FUJI COMPUTED RADIOGRAPHY SYSTEM FCR AC-1 (FCR)
K
89
2711
QUANTIM 2000I DIGITAL IMAGE ANALYSIS SYSTEM
K
89
4402
HIPGRAPHICS SYSTEM ONE W/ORTHOTOOL
K
89
5320
FLUOROVISION HR 2000 HIGH RESOLUTION IMAGE ENHANCE
K
89
2397
MODIFIED CEDARS-SINAI QUANTI THALLIUM-201 ANALYSIS
K
89
1692
MIP MR
K
89
1689
MIPRON/UMIPRON
K
89
1695
VIEW 1000
K
89
2712
MIP/CT IMAGE PROCESSING WORKSTATION
K
89
3585
14 COLOR VIDEO DISPLAY 211-260-010
K
89
3521
IMLOGIX 1000 IMAGE DISPLAY SYSTEM
K
89
2869
ANGIOTEC ZX DIGITAL IMAGE PROCESSOR
K
88
4621
DIGISCAN
K
89
0397
REDI-VU MODEL RV-386
K
88
4995
SIEMENS PACS/1-B (OPTICAL DISK OPTION)
K
88
5318
DIGITRON 3, LV ANALYSIS PROTCOL
K
88
2933
DACA-100
K
88
3476
VOXEL FLINGER(TM) 3-D IMAGING SYSTEM
K
88
3604
MEDRAD IMAGE MANAGEMENT SYSTEM (MIMS)
K
88
2271
CTQ - CEDARS-SINAI QUANTITATIVE THALLIUM-201 ANALY
K
88
1481
DIGITRON STENOSIS PROTOCOL
K
88
1993
PXI (PERSONAL X-RAY IMAGER) 512
K
88
2205
VIEWPOINT
K
88
1017
DPS-33,000 WITH CENTOR OPTION
K
88
0169
CEMAX 5000 MULTIDIMENSIONAL IMAGING WORKSTATION
K
87
4865
DAMON D.E.T.E.C.T IMAGE ENHANCER
K
87
3646
DIGIVIEWER
K
87
2455
DPS-4100 PLUS DIGITAL RADIOGRAPHY SYSTEM
K
87
0821
POLYTRON MODELS 1001, 1002 AND 1004
K
86
4854
VIEW(TM) IMAGE PROCESSING AND VIEWING STATION
K
86
4519
PHILIPS COMPUTED RADIOGRAPHY SYSTEM (PCR)
K
86
4739
KODAK EKTASCAN IMAGE TRANSMISSION SYSTEM P1
K
86
4927
KODAK EKTASCAN IMAGE TRANS SYS T1/R1 SOFTWARE,1.10
K
86
3132
DIGITAL FLUORICON CARDIAC/VASCULAR QUANTITATIVE
K
86
2294
THE IMAGE/R
K
86
1514
VNA OPTICAL CORRELATOR
K
86
2309
PC-DISPLAY
K
86
1852
CSI/MPR OR CSI/MPR PLUS
K
86
1429
DIGITRON 3V,3VA,3VAC,3 HIGH RESOLUTION UPGRADE
K
86
1279
FLUORO PLUS
K
85
4810
FC-1000 FLUOROSCOPIC IMAGING COMPUTER
K
85
5002
KODAK EKTASCAN IMAGE TRANSMISSION SYSTEM
K
85
2284
DIGIRAD SYSTEM 1 AND THE REUSUABLE IMAGE MEDIA
K
85
0080
DIGITAL IMAGE PROCESSOR FP-2C
K
84
3708
ADAC DPS-4070 DIGITAL RADIOGRAPHY SYS
K
84
4298
ADAC MODEL DPS-3300M DIGITAL PROCESSING SYSTEM
K
84
4037
DIGITAL FLUOROGRAPHIC IMAGING SYSTEM DIGIFORMER
K
84
4317
DMI CONSOLE
K
84
4783
DPS-3300 MICRO NUCLEAR MEDICINE IMAGING COMPUTER
K
84
4784
DPS-33000 NUCLEAR MEDICINE IMAGING COMPUTER
K
83
2895
VISION TWO, ONE/10 ONE/20 &24
LMA
Digitizer, Image, Radiological
LMB
Device, Digital Image Storage, Radiological
LMC
Camera, Multi Format, Radiological
LMD
System, Digital Image Communications, Radiological
LNH
System, Nuclear Magnetic Resonance Imaging
LNI
System, Nuclear Magnetic Resonance Spectroscopic
LQA
Media, Reusable Image
MOS
Coil, Magnetic Resonance, Specialty
MQB
Solid State X-Ray Imager (Flat Panel/Digital Imager)
MUA
Bone Sonometer
MUE
Full Field Digital, System, X-Ray, Mammographic
MUI
Media, Coupling, Ultrasound
MWP
Cabinet, X-Ray System
MYN
Analyzer, Medical Image
NCS
System, Imaging, Holography, Acoustic
NWE
Colon Computed Tomography System, Computer Aided Detection
OAS
X-Ray, Tomography, Computed, Dental
OEB
Lung Computed Tomography System, Computer-Aided Detection
OII
Arthrogram Tray
OIJ
Biopsy Needle Guide Kit
OIK
Radiology Dental Tray
OIL
Discography Kit
OIM
Mri Disposable Kit
OIO
Radiographic Contrast Tray
OIP
Radiology-Diagnostic Kit
OMJ
Chest X-Ray Computer Aided Detection
OQQ
Diagnostic Ultrasonic Transducer, Robotic
OUO
Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
OWB
Interventional Fluoroscopic X-Ray System
OXO
Image-Intensified Fluoroscopic X-Ray System, Mobile
PCS
Liver Iron Concentration Imaging Companion Diagnostic For Deferasirox
PGY
Display, Diagnostic Radiology
POK
Computer-Assisted Diagnostic Software For Lesions Suspicious For Cancer
QAS
Radiological Computer-Assisted Triage And Notification Software
QBS
Radiological Computer Assisted Detection/Diagnosis Software For Fracture
QDQ
Radiological Computer Assisted Detection/Diagnosis Software For Lesions Suspicious For Cancer
QFM
Radiological Computer-Assisted Prioritization Software For Lesions
QHA
X-Ray Angiographic Imaging Based Coronary Vascular Simulation Software Device
QHX
Fluoroscopic X-Ray Image Intensifier
QHY
Solid State Fluoroscopic X-Ray Imager
QIH
Automated Radiological Image Processing Software
QJU
Image Acquisition And/Or Optimization Guided By Artificial Intelligence
QKB
Radiological Image Processing Software For Radiation Therapy
RCC
C-Arm Fluoroscopic X-Ray System
QTZ
Radiological Image Processing Software For Ablation Therapy Planning And Evaluation
QXL
Cabinet, Emission Computed Tomography System
SFV
X-Ray, Computed Tomography, Cone-Beam
Subpart C—Obstetrical and Gynecological Monitoring Devices
Subpart F—Therapeutic Devices
Subpart G—Miscellaneous Devices
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
RA
/
subpart-b—diagnostic-devices
/
LLZ
/
K042292
View Source
ISITE PACS
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K042292
510(k) Type
Traditional
Applicant
Stentor, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
9/8/2004
Days to Decision
15 days
Submission Type
Summary