FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
MOC
Cushion, Flotation, Therapeutic
2
Product Code
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
2
Product Code
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
2
Product Code
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
2
Product Code
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
2
Product Code
BXB
Exerciser, Powered
1
Product Code
EGJ
Device, Iontophoresis, Other Uses
2
Product Code
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
IKW
Utensil, Homemaking
1
Product Code
IKX
Aid, Transfer
1
Product Code
IKZ
Bed, Patient Rotation, Powered
2
Product Code
ILC
Utensil, Eating
1
Product Code
ILD
Adaptor, Dressing
1
Product Code
ILJ
Bath, Hydro-Massage
2
Product Code
ILK
Transport, Patient, Powered
2
Product Code
ILM
Bath, Sitz, Powered
2
Product Code
ILO
Pack, Hot Or Cold, Water Circulating
2
Product Code
ILS
Adaptor, Hygiene
1
Product Code
ILT
Adaptor, Recreational
1
Product Code
ILW
Adaptor, Grooming
1
Product Code
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
2
Product Code
ILY
Lamp, Infrared, Therapeutic Heating
2
Product Code
ILZ
Accessories, Traction
1
Product Code
IMA
Pack, Heat, Moist
1
Product Code
IMB
Cabinet, Moist Steam
2
Product Code
IMC
Bath, Paraffin
2
Product Code
IMD
Pack, Hot Or Cold, Disposable
1
Product Code
IME
Pack, Hot Or Cold, Reusable
1
Product Code
IMF
Unit, Chilling
1
Product Code
INX
Bed, Air Fluidized
2
Product Code
INY
Bed, Patient Rotation, Manual
1
Product Code
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
IOB
Lamp, Infrared, Non Heating
2
Product Code
IOD
Components, Exercise
1
Product Code
IOE
Bars, Parallel, Exercise
1
Product Code
IOG
Treadmill, Mechanical
1
Product Code
IOL
Treadmill, Powered
1
Product Code
ION
Exerciser, Non-Measuring
1
Product Code
IOQ
Bed, Flotation Therapy, Powered
2
Product Code
IPF
Stimulator, Muscle, Powered
2
Product Code
IRN
Device, Warning, Overload, External Limb, Powered
2
Product Code
IRO
Vibrator, Therapeutic
1
Product Code
IRP
Massager, Powered Inflatable Tube
2
Product Code
IRQ
Unit, Heating, Powered
1
Product Code
IRR
Bars, Parallel, Powered
1
Product Code
IRS
Head Halter, Traction
1
Product Code
IRT
Pad, Heating, Powered
2
Product Code
ISA
Massager, Therapeutic, Electric
1
Product Code
ISD
Exerciser, Measuring
2
Product Code
ITH
Equipment, Traction, Powered
2
Product Code
JFA
Exerciser, Finger, Powered
1
Product Code
JFB
Table, Physical Therapy, Multi Function
2
Product Code
KNL
Board, Scooter, Prone
1
Product Code
KNM
Device, Pressure Applying
1
Product Code
KTB
Device, Iontophoresis, Specific Uses
2
Product Code
KTC
Bath, Sitz, Nonpowered
1
Product Code
LBG
Device, Fluidized Therapy, Dry Heat
2
Product Code
LSB
Unit, Fluidotherapy
2
Product Code
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
LXJ
Interactive Rehabilitation Exercise Devices
2
Product Code
LYG
Massager, Therapeutic, Manual
1
Product Code
MPO
Infant Heel Warmer (Chemical Heat Pack)
1
Product Code
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
2
Product Code
K
25
3408
CoolTone
2
Cleared 510(K)
K
25
2154
Portable Electro Stimulation Therapy Device (LGT-2320BE, LGT-2320ME, and LGT-2320SP)
2
Cleared 510(K)
K
25
3478
Motive™ Muscle Stimulator for Lower Back (OT01-1003)
2
Cleared 510(K)
K
25
1594
truFlex
2
Cleared 510(K)
K
25
1706
TENS and EMS Unit
2
Cleared 510(K)
K
25
1378
CoolTone
2
Cleared 510(K)
K
25
1746
Pure Impact
2
Cleared 510(K)
K
25
0759
3 in 1 TENS UNIT
2
Cleared 510(K)
K
24
2926
XBody Go USA, XBody Pro USA
2
Cleared 510(K)
K
25
0038
Muscle Stimulator Device (PZ-100)
2
Cleared 510(K)
K
24
3165
Limfa Therapy System (Limfa Therapy)
2
Cleared 510(K)
K
25
0146
SofWave System
2
Cleared 510(K)
K
24
3763
Wireless TENS & EMS Unit
2
Cleared 510(K)
K
24
1601
EMS (FlexPulse, MagnaCore, Magnetika)
2
Cleared 510(K)
K
24
3511
OTC TENS & EMS Unit
2
Cleared 510(K)
K
23
3770
Pepper EMS Training System
2
Cleared 510(K)
K
24
2787
Tens & Ems Device (TU1080)
2
Cleared 510(K)
K
23
2982
EMS Sculpt Machine
2
Cleared 510(K)
K
24
2186
Neo Sculptor (OF-NEO001)
2
Cleared 510(K)
K
24
1685
SofWave System
2
Cleared 510(K)
K
24
0347
PTG-05
2
Cleared 510(K)
K
23
0711
Pain Therapy Device(Model: P.T.S-X)
2
Cleared 510(K)
K
23
2181
Body Contouring Machine (Models: CS2, CS3, CS5, CS7, CS8, CS11, CS13)
2
Cleared 510(K)
K
23
2409
Electromagnetic Stimulation Systems
2
Cleared 510(K)
K
23
3070
Smart Muscle Training Wearables (Model:SM9027,SM9027,SM9566,SM9065N)
2
Cleared 510(K)
K
23
1789
Pain Therapy Device (Model: P.T.S-VI, P.T.S-VII)
2
Cleared 510(K)
K
22
2400
Coresculpt & Magsculpt
2
Cleared 510(K)
K
23
3035
Electronic Muscle Stimulator (Model MP01)
2
Cleared 510(K)
K
23
3492
EMS Neck Massager
2
Cleared 510(K)
K
23
3470
DEKA LILY
2
Cleared 510(K)
K
23
0024
HI-EMT MAGSHAPE
2
Cleared 510(K)
K
22
0938
Nova HD+
2
Cleared 510(K)
K
23
1318
Electromagnetic Stimulator Device(Model EM Contouring and Tesla Duet)
2
Cleared 510(K)
K
23
1136
Fitness Belt (Model: KLT-07)
2
Cleared 510(K)
K
23
1368
Bemer Therapy System Evo
2
Cleared 510(K)
K
23
0261
Gnesis EMS Plus
2
Cleared 510(K)
K
22
2875
Powered Muscle Stimulator (Model name:MagGraver F200)
2
Cleared 510(K)
K
22
2386
Visionbody
2
Cleared 510(K)
K
22
3797
Neuro20 Pro System
2
Cleared 510(K)
K
22
1200
XBody Go USA, XBody Pro USA
2
Cleared 510(K)
K
21
2866
truSculpt flex
2
Cleared 510(K)
K
21
3748
CoreLevee
2
Cleared 510(K)
K
22
1498
Miha Bodytec II
2
Cleared 510(K)
K
21
1298
WiEMSpro
2
Cleared 510(K)
K
21
2413
I-Motion
2
Cleared 510(K)
K
22
0601
CoolTone
2
Cleared 510(K)
K
21
0825
Revitive Medic Coach (Model Number 5575AQ)
2
Cleared 510(K)
K
21
1942
Heating Lumbar Therapy Cushion (Model: AST-622, AST-622B, AST-623, AST-623B)
2
Cleared 510(K)
K
21
2948
Pain Therapy Device(Model: DH-P.T.S-I, DH-P.T.S-II, DH-P.T.S-IIA, DH-P.T.S-IIB, DH-CP-I)
2
Cleared 510(K)
K
20
0545
Legend Pro DMA
2
Cleared 510(K)
K
20
2148
E-Fit Infinity System (EF-2090 Controller and EF-100 Unit)
2
Cleared 510(K)
K
20
2638
Pain Therapy Device
2
Cleared 510(K)
K
20
1257
MI.BO. ® MyoBoost EMS System (MB-1000, MB-600, MB-400)
2
Cleared 510(K)
K
20
1975
miha bodytec II
2
Cleared 510(K)
K
20
3513
SLENDERTONE Evolve Abs, Type 735
2
Cleared 510(K)
K
21
0174
BEMER Therapy Systems, BEMER Classic Set, BEMER Pro-Set
2
Cleared 510(K)
K
20
2653
Gymform Total ABS
2
Cleared 510(K)
K
20
0382
BTL-703-2
2
Cleared 510(K)
K
20
1239
NuEra Tight Family, EMS Model
2
Cleared 510(K)
K
20
1354
TENS & PMS
2
Cleared 510(K)
K
20
1653
Compex Sport Elite 3.0
2
Cleared 510(K)
K
20
1845
Portable Electro-Stimulation Therapy Device, Model: LGT-232(US)
2
Cleared 510(K)
K
18
2020
Portable Electro-Stimulation Therapy Device
2
Cleared 510(K)
K
19
1938
FitRelief TENS&EMS Wireless Device
2
Cleared 510(K)
K
20
1131
firefly T-2
2
Cleared 510(K)
K
19
2887
Revitive Medic Plus, Revitive Advanced 2
2
Cleared 510(K)
K
19
2039
Torc Body
2
Cleared 510(K)
K
19
0966
Katalyst Training System
2
Cleared 510(K)
K
19
2161
FastFit EMS System
2
Cleared 510(K)
K
19
2940
CoolTone
2
Cleared 510(K)
K
19
2264
HIVOX Spopad EMS SP-911, SP-921
2
Cleared 510(K)
K
19
1181
NXPRO Neuromuscular Electrical Stimulation Device
2
Cleared 510(K)
K
18
3103
EMS Belt (Model MC0485)
2
Cleared 510(K)
K
18
2794
BionicGym Powered Muscle Stimulator
2
Cleared 510(K)
K
19
0924
Revitive Medic Plus, Revitive Advanced 2
2
Cleared 510(K)
K
19
0456
BTL 799-2L
2
Cleared 510(K)
K
18
2963
emFieldPro
2
Cleared 510(K)
K
18
2519
Miha Bodytec II
2
Cleared 510(K)
K
18
1419
FLIX-EMS
2
Cleared 510(K)
K
19
0038
Xbody Newave USA
2
Cleared 510(K)
K
18
3454
Tyece OTC EMS System
2
Cleared 510(K)
K
18
2440
Body System
2
Cleared 510(K)
K
18
1955
WiEMSpro
2
Cleared 510(K)
K
18
0688
SLENDERTONE CoreFit Abs 8, Type 734
2
Cleared 510(K)
K
18
2106
BTL 799-2T
2
Cleared 510(K)
K
18
1728
Muscle Trainer
2
Cleared 510(K)
K
18
1199
Katalyst Mark 1 Muscle Stimulation System Model 2
2
Cleared 510(K)
K
18
0813
BTL 799-2
2
Cleared 510(K)
K
18
0279
Silk'n MODEL H5003 device
2
Cleared 510(K)
K
17
2876
PowerDot PD-01M
2
Cleared 510(K)
K
17
2241
Tyece OTC EMS System, Model EM35
2
Cleared 510(K)
K
17
1035
Katalyst Mark 1 Muscle Stimulation System
2
Cleared 510(K)
K
16
2744
Everyway OTC EMS, Model EV-805
2
Cleared 510(K)
K
17
1092
XiniWave II Model ECS322P
2
Cleared 510(K)
K
17
0918
Compex Sport Elite
2
Cleared 510(K)
K
17
0903
Compex Wireless USA
2
Cleared 510(K)
K
16
0323
FlowKeepers
2
Cleared 510(K)
K
15
1834
BEMER Classic Set, BEMER Pro-Set
2
Cleared 510(K)
K
16
3165
AM-100
2
Cleared 510(K)
K
15
2420
AK Body Toning Device
2
Cleared 510(K)
K
16
1974
SLENDERTONE® Connect Abs, Type 570
2
Cleared 510(K)
K
15
2480
Revitive Medic; Revitive MV; Revitive LV
2
Cleared 510(K)
K
15
1722
Slim UP ULTRA
2
Cleared 510(K)
K
15
1903
Slendertone connect Abs
2
Cleared 510(K)
K
15
0078
PowerDot(R) PD-01 Muscle Stimulator (with PowerDot(R) Mobile Application)
2
Cleared 510(K)
K
14
3737
EM25 - glute toning device
2
Cleared 510(K)
K
14
1919
VEINOPLUS SPORT NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
14
2055
GYMFORM ABS & CORE
2
Cleared 510(K)
K
14
3551
Compex Wireless USA
2
Cleared 510(K)
K
14
3207
Revitive IX (OTC)
2
Cleared 510(K)
K
14
3059
TAMTEC-HANA TENS / EMS (Sport Muscle Stimulator)
2
Cleared 510(K)
K
14
1921
HIVOX SPOPAD EMS
2
Cleared 510(K)
K
13
3225
E-FIT EF-1280 EMS MACHINE
2
Cleared 510(K)
K
13
3108
FIT BELT
2
Cleared 510(K)
K
13
3965
OTC EMS STIMULATOR
2
Cleared 510(K)
K
13
4001
FIREFLY
2
Cleared 510(K)
K
13
2179
ARASYS
2
Cleared 510(K)
K
13
0723
FDES106 MINI TENS&EMS DEVICE,FDES106 MULTI-FUNCTION MINI TENS&EMS DEVICE,FDES105 PAIN RELIEF PLASTER,FDES107 ABDOMINAL
2
Cleared 510(K)
K
12
2393
TG-BODY MI&BODY S-TRAINER
2
Cleared 510(K)
K
13
0074
GYMFORM ABS-A-ROUND
2
Cleared 510(K)
K
12
3075
BUTTOCK MUSCLE STIMULATOR MODEL WL-2413B; BUTTOCK MUSCLE STIMULATOR MODE WL-2413E
2
Cleared 510(K)
K
12
3158
ION MAGNUM GENIUS
2
Cleared 510(K)
K
13
1291
TORC BODY
2
Cleared 510(K)
K
12
1719
SM TENS & PMS
2
Cleared 510(K)
K
12
2414
AB COMMAND DUAL CHANNEL FITNESS BELT
2
Cleared 510(K)
K
11
1781
GYMFORM DUAL FLEX BELT MODEL WB-162
2
Cleared 510(K)
K
11
1476
CONTOUR TECHNOLOGY MUSCLE STIMULATOR
2
Cleared 510(K)
K
11
0057
MINI MASSEUSE
2
Cleared 510(K)
K
10
2933
GEM-TONE BODY TRAINING SYSTEM
2
Cleared 510(K)
K
10
2926
GEMORE MUSCLE CONDITIONER;
2
Cleared 510(K)
K
10
2786
WELL-LIFE OTC EMS SYSTEM
2
Cleared 510(K)
K
10
2295
X2ABS DUAL CHANNEL FITNESS BELT
2
Cleared 510(K)
K
09
3999
ARP POV SPORT
2
Cleared 510(K)
K
10
0556
SLENDERTONE FLEX MAX, MODEL 517 US
2
Cleared 510(K)
K
09
2476
SPORT-ELEC BODY CONTROL SYSTEM, MODEL 4M
2
Cleared 510(K)
K
10
0320
SLENDERTONE SYSTEM ULTRA MODEL E70/X70
2
Cleared 510(K)
K
09
2142
SPORT-ELEC BODY CONTROL SYSTEM BS
2
Cleared 510(K)
K
09
3368
BUTTERFLY TONER MODEL GYM070
2
Cleared 510(K)
K
09
1865
SPORT-ELEC BODY CONTROL SYSTEM
2
Cleared 510(K)
K
09
1833
GEM-STONE ABDOMINAL TRAINING SYSTEM; MODEL GEM-TONE 310PE/320PE/330PE/340PE/350PE.
2
Cleared 510(K)
K
08
1998
H-WAVE SPORT
2
Cleared 510(K)
K
08
3140
COMPEX SPORT PLUS
2
Cleared 510(K)
K
08
3164
SYSTEM-ARMS, MODELS 390, X60
2
Cleared 510(K)
K
08
1026
BODY CONTROL SYSTEM FAMILY, BODY CONTROL DUO AND CT5
2
Cleared 510(K)
K
07
1666
SLENDERTONE ENERVIVE, MODEL 561
2
Cleared 510(K)
K
07
2168
OTC ABDOMEN & THIGH SYSTEM, MODEL: WL-2410, WL-2411 AND WL-2412
2
Cleared 510(K)
K
07
2553
SYSTEM-ARMS, MODEL 390,E60
2
Cleared 510(K)
K
07
2294
SYSTEM-MINI, MODELS: 390, E30
2
Cleared 510(K)
K
06
1914
SPORT-ELEC, MODELS DUO CT5 SLIMNESS AND CT5 SLIMNESS
2
Cleared 510(K)
K
06
1632
GLOBUS PREMIUM MUSCLE STIMULATOR
2
Cleared 510(K)
K
07
0142
SLENDERTONE SYSTEM ABS, MODELS 390, E10, X10; SLENDERTONE SYSTEM SHORTS, MODELS 390, E20
2
Cleared 510(K)
K
06
2439
POWERTONE, MODEL PT-11
2
Cleared 510(K)
K
05
2969
SLENDERTONE GYMBODY, MODEL 512-01
2
Cleared 510(K)
K
03
1611
P4-FITNESS
2
Cleared 510(K)
K
03
0708
SLENDERTONE FLEX ABDOMINAL TRAINING SYSTEM, TYPE 515
2
Cleared 510(K)
K
02
2855
SLENDERTONE FLEX BOTTOM & THIGH TONING SYSTEM, TYPE 511
2
Cleared 510(K)
K
02
0429
AB BELT PRO
2
Cleared 510(K)
K
02
0427
AB BELT
2
Cleared 510(K)
K
01
1880
COMPEX SPORT
2
Cleared 510(K)
K
01
0335
SLENDERTONE FLEX, MODEL, 512
2
Cleared 510(K)
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
2
Product Code
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
2
Product Code
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
2
Product Code
OMW
Adhesive Backed Thermal Skin Patches
1
Product Code
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
2
Product Code
PCD
Powered Stairway Chair Lift
2
Product Code
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
2
Product Code
PHW
Cold Pack And Vibrating Massager
1
Product Code
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
1
Product Code
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
2
Product Code
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
2
Product Code
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
2
Product Code
QTC
Adult Portable Bed Rails For Medical Purposes
1
Product Code
SGT
Electromagnetic Stimulator For Healthy Muscle Stimulation
2
Product Code
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
NGX
/
K093999
View Source
ARP POV SPORT
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K093999
510(k) Type
Traditional
Applicant
Arp Manufacturing, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
8/10/2010
Days to Decision
225 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
Subpart D—Physical Medicine Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
MOC
Cushion, Flotation, Therapeutic
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
BXB
Exerciser, Powered
EGJ
Device, Iontophoresis, Other Uses
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
IKW
Utensil, Homemaking
IKX
Aid, Transfer
IKZ
Bed, Patient Rotation, Powered
ILC
Utensil, Eating
ILD
Adaptor, Dressing
ILJ
Bath, Hydro-Massage
ILK
Transport, Patient, Powered
ILM
Bath, Sitz, Powered
ILO
Pack, Hot Or Cold, Water Circulating
ILS
Adaptor, Hygiene
ILT
Adaptor, Recreational
ILW
Adaptor, Grooming
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
ILY
Lamp, Infrared, Therapeutic Heating
ILZ
Accessories, Traction
IMA
Pack, Heat, Moist
IMB
Cabinet, Moist Steam
IMC
Bath, Paraffin
IMD
Pack, Hot Or Cold, Disposable
IME
Pack, Hot Or Cold, Reusable
IMF
Unit, Chilling
INX
Bed, Air Fluidized
INY
Bed, Patient Rotation, Manual
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
IOB
Lamp, Infrared, Non Heating
IOD
Components, Exercise
IOE
Bars, Parallel, Exercise
IOG
Treadmill, Mechanical
IOL
Treadmill, Powered
ION
Exerciser, Non-Measuring
IOQ
Bed, Flotation Therapy, Powered
IPF
Stimulator, Muscle, Powered
IRN
Device, Warning, Overload, External Limb, Powered
IRO
Vibrator, Therapeutic
IRP
Massager, Powered Inflatable Tube
IRQ
Unit, Heating, Powered
IRR
Bars, Parallel, Powered
IRS
Head Halter, Traction
IRT
Pad, Heating, Powered
ISA
Massager, Therapeutic, Electric
ISD
Exerciser, Measuring
ITH
Equipment, Traction, Powered
JFA
Exerciser, Finger, Powered
JFB
Table, Physical Therapy, Multi Function
KNL
Board, Scooter, Prone
KNM
Device, Pressure Applying
KTB
Device, Iontophoresis, Specific Uses
KTC
Bath, Sitz, Nonpowered
LBG
Device, Fluidized Therapy, Dry Heat
LSB
Unit, Fluidotherapy
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
LXJ
Interactive Rehabilitation Exercise Devices
LYG
Massager, Therapeutic, Manual
MPO
Infant Heel Warmer (Chemical Heat Pack)
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
K
25
3408
CoolTone
K
25
2154
Portable Electro Stimulation Therapy Device (LGT-2320BE, LGT-2320ME, and LGT-2320SP)
K
25
3478
Motive™ Muscle Stimulator for Lower Back (OT01-1003)
K
25
1594
truFlex
K
25
1706
TENS and EMS Unit
K
25
1378
CoolTone
K
25
1746
Pure Impact
K
25
0759
3 in 1 TENS UNIT
K
24
2926
XBody Go USA, XBody Pro USA
K
25
0038
Muscle Stimulator Device (PZ-100)
K
24
3165
Limfa Therapy System (Limfa Therapy)
K
25
0146
SofWave System
K
24
3763
Wireless TENS & EMS Unit
K
24
1601
EMS (FlexPulse, MagnaCore, Magnetika)
K
24
3511
OTC TENS & EMS Unit
K
23
3770
Pepper EMS Training System
K
24
2787
Tens & Ems Device (TU1080)
K
23
2982
EMS Sculpt Machine
K
24
2186
Neo Sculptor (OF-NEO001)
K
24
1685
SofWave System
K
24
0347
PTG-05
K
23
0711
Pain Therapy Device(Model: P.T.S-X)
K
23
2181
Body Contouring Machine (Models: CS2, CS3, CS5, CS7, CS8, CS11, CS13)
K
23
2409
Electromagnetic Stimulation Systems
K
23
3070
Smart Muscle Training Wearables (Model:SM9027,SM9027,SM9566,SM9065N)
K
23
1789
Pain Therapy Device (Model: P.T.S-VI, P.T.S-VII)
K
22
2400
Coresculpt & Magsculpt
K
23
3035
Electronic Muscle Stimulator (Model MP01)
K
23
3492
EMS Neck Massager
K
23
3470
DEKA LILY
K
23
0024
HI-EMT MAGSHAPE
K
22
0938
Nova HD+
K
23
1318
Electromagnetic Stimulator Device(Model EM Contouring and Tesla Duet)
K
23
1136
Fitness Belt (Model: KLT-07)
K
23
1368
Bemer Therapy System Evo
K
23
0261
Gnesis EMS Plus
K
22
2875
Powered Muscle Stimulator (Model name:MagGraver F200)
K
22
2386
Visionbody
K
22
3797
Neuro20 Pro System
K
22
1200
XBody Go USA, XBody Pro USA
K
21
2866
truSculpt flex
K
21
3748
CoreLevee
K
22
1498
Miha Bodytec II
K
21
1298
WiEMSpro
K
21
2413
I-Motion
K
22
0601
CoolTone
K
21
0825
Revitive Medic Coach (Model Number 5575AQ)
K
21
1942
Heating Lumbar Therapy Cushion (Model: AST-622, AST-622B, AST-623, AST-623B)
K
21
2948
Pain Therapy Device(Model: DH-P.T.S-I, DH-P.T.S-II, DH-P.T.S-IIA, DH-P.T.S-IIB, DH-CP-I)
K
20
0545
Legend Pro DMA
K
20
2148
E-Fit Infinity System (EF-2090 Controller and EF-100 Unit)
K
20
2638
Pain Therapy Device
K
20
1257
MI.BO. ® MyoBoost EMS System (MB-1000, MB-600, MB-400)
K
20
1975
miha bodytec II
K
20
3513
SLENDERTONE Evolve Abs, Type 735
K
21
0174
BEMER Therapy Systems, BEMER Classic Set, BEMER Pro-Set
K
20
2653
Gymform Total ABS
K
20
0382
BTL-703-2
K
20
1239
NuEra Tight Family, EMS Model
K
20
1354
TENS & PMS
K
20
1653
Compex Sport Elite 3.0
K
20
1845
Portable Electro-Stimulation Therapy Device, Model: LGT-232(US)
K
18
2020
Portable Electro-Stimulation Therapy Device
K
19
1938
FitRelief TENS&EMS Wireless Device
K
20
1131
firefly T-2
K
19
2887
Revitive Medic Plus, Revitive Advanced 2
K
19
2039
Torc Body
K
19
0966
Katalyst Training System
K
19
2161
FastFit EMS System
K
19
2940
CoolTone
K
19
2264
HIVOX Spopad EMS SP-911, SP-921
K
19
1181
NXPRO Neuromuscular Electrical Stimulation Device
K
18
3103
EMS Belt (Model MC0485)
K
18
2794
BionicGym Powered Muscle Stimulator
K
19
0924
Revitive Medic Plus, Revitive Advanced 2
K
19
0456
BTL 799-2L
K
18
2963
emFieldPro
K
18
2519
Miha Bodytec II
K
18
1419
FLIX-EMS
K
19
0038
Xbody Newave USA
K
18
3454
Tyece OTC EMS System
K
18
2440
Body System
K
18
1955
WiEMSpro
K
18
0688
SLENDERTONE CoreFit Abs 8, Type 734
K
18
2106
BTL 799-2T
K
18
1728
Muscle Trainer
K
18
1199
Katalyst Mark 1 Muscle Stimulation System Model 2
K
18
0813
BTL 799-2
K
18
0279
Silk'n MODEL H5003 device
K
17
2876
PowerDot PD-01M
K
17
2241
Tyece OTC EMS System, Model EM35
K
17
1035
Katalyst Mark 1 Muscle Stimulation System
K
16
2744
Everyway OTC EMS, Model EV-805
K
17
1092
XiniWave II Model ECS322P
K
17
0918
Compex Sport Elite
K
17
0903
Compex Wireless USA
K
16
0323
FlowKeepers
K
15
1834
BEMER Classic Set, BEMER Pro-Set
K
16
3165
AM-100
K
15
2420
AK Body Toning Device
K
16
1974
SLENDERTONE® Connect Abs, Type 570
K
15
2480
Revitive Medic; Revitive MV; Revitive LV
K
15
1722
Slim UP ULTRA
K
15
1903
Slendertone connect Abs
K
15
0078
PowerDot(R) PD-01 Muscle Stimulator (with PowerDot(R) Mobile Application)
K
14
3737
EM25 - glute toning device
K
14
1919
VEINOPLUS SPORT NEUROMUSCULAR STIMULATOR
K
14
2055
GYMFORM ABS & CORE
K
14
3551
Compex Wireless USA
K
14
3207
Revitive IX (OTC)
K
14
3059
TAMTEC-HANA TENS / EMS (Sport Muscle Stimulator)
K
14
1921
HIVOX SPOPAD EMS
K
13
3225
E-FIT EF-1280 EMS MACHINE
K
13
3108
FIT BELT
K
13
3965
OTC EMS STIMULATOR
K
13
4001
FIREFLY
K
13
2179
ARASYS
K
13
0723
FDES106 MINI TENS&EMS DEVICE,FDES106 MULTI-FUNCTION MINI TENS&EMS DEVICE,FDES105 PAIN RELIEF PLASTER,FDES107 ABDOMINAL
K
12
2393
TG-BODY MI&BODY S-TRAINER
K
13
0074
GYMFORM ABS-A-ROUND
K
12
3075
BUTTOCK MUSCLE STIMULATOR MODEL WL-2413B; BUTTOCK MUSCLE STIMULATOR MODE WL-2413E
K
12
3158
ION MAGNUM GENIUS
K
13
1291
TORC BODY
K
12
1719
SM TENS & PMS
K
12
2414
AB COMMAND DUAL CHANNEL FITNESS BELT
K
11
1781
GYMFORM DUAL FLEX BELT MODEL WB-162
K
11
1476
CONTOUR TECHNOLOGY MUSCLE STIMULATOR
K
11
0057
MINI MASSEUSE
K
10
2933
GEM-TONE BODY TRAINING SYSTEM
K
10
2926
GEMORE MUSCLE CONDITIONER;
K
10
2786
WELL-LIFE OTC EMS SYSTEM
K
10
2295
X2ABS DUAL CHANNEL FITNESS BELT
K
09
3999
ARP POV SPORT
K
10
0556
SLENDERTONE FLEX MAX, MODEL 517 US
K
09
2476
SPORT-ELEC BODY CONTROL SYSTEM, MODEL 4M
K
10
0320
SLENDERTONE SYSTEM ULTRA MODEL E70/X70
K
09
2142
SPORT-ELEC BODY CONTROL SYSTEM BS
K
09
3368
BUTTERFLY TONER MODEL GYM070
K
09
1865
SPORT-ELEC BODY CONTROL SYSTEM
K
09
1833
GEM-STONE ABDOMINAL TRAINING SYSTEM; MODEL GEM-TONE 310PE/320PE/330PE/340PE/350PE.
K
08
1998
H-WAVE SPORT
K
08
3140
COMPEX SPORT PLUS
K
08
3164
SYSTEM-ARMS, MODELS 390, X60
K
08
1026
BODY CONTROL SYSTEM FAMILY, BODY CONTROL DUO AND CT5
K
07
1666
SLENDERTONE ENERVIVE, MODEL 561
K
07
2168
OTC ABDOMEN & THIGH SYSTEM, MODEL: WL-2410, WL-2411 AND WL-2412
K
07
2553
SYSTEM-ARMS, MODEL 390,E60
K
07
2294
SYSTEM-MINI, MODELS: 390, E30
K
06
1914
SPORT-ELEC, MODELS DUO CT5 SLIMNESS AND CT5 SLIMNESS
K
06
1632
GLOBUS PREMIUM MUSCLE STIMULATOR
K
07
0142
SLENDERTONE SYSTEM ABS, MODELS 390, E10, X10; SLENDERTONE SYSTEM SHORTS, MODELS 390, E20
K
06
2439
POWERTONE, MODEL PT-11
K
05
2969
SLENDERTONE GYMBODY, MODEL 512-01
K
03
1611
P4-FITNESS
K
03
0708
SLENDERTONE FLEX ABDOMINAL TRAINING SYSTEM, TYPE 515
K
02
2855
SLENDERTONE FLEX BOTTOM & THIGH TONING SYSTEM, TYPE 511
K
02
0429
AB BELT PRO
K
02
0427
AB BELT
K
01
1880
COMPEX SPORT
K
01
0335
SLENDERTONE FLEX, MODEL, 512
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
OMW
Adhesive Backed Thermal Skin Patches
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
PCD
Powered Stairway Chair Lift
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
PHW
Cold Pack And Vibrating Massager
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
QTC
Adult Portable Bed Rails For Medical Purposes
SGT
Electromagnetic Stimulator For Healthy Muscle Stimulation
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
NGX
/
K093999
View Source
ARP POV SPORT
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K093999
510(k) Type
Traditional
Applicant
Arp Manufacturing, Inc.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
8/10/2010
Days to Decision
225 days
Submission Type