Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation

Page Type
Product Code
Definition
Used for muscle stimulation for rehabilitation. Device repeatedly contracts muscles by passing pulsed electrical current through cutaneous electrodes contacting the affected body area. Indicated for use as an adjunctive therapy in rehabilitation for medical purposes such as relaxation of muscle spasm, prevention or retardation of disuse atrophy, increasing local blood circulation, muscle re-education, maintaining or increasing range of motion, and immediate post-surgical stimulation of calf muscles to prevent venous thrombosis.
Physical State
Electrical stimulation unit with leads and cutaneous electrodes
Technical Method
Stimulation of muscles using electrical current applied to electrodes on a patient's skin
Target Area
Electrodes are placed on the skin overlying the muscle or motor nerve to be stimulated
Regulation Medical Specialty
Physical Medicine
Review Panel
Physical Medicine
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
890.5850
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Third Party Eligible

CFR § 890.5850 Powered muscle stimulator

§ 890.5850 Powered muscle stimulator.

(a) Identification. A powered muscle stimulator is an electrically powered device intended for medical purposes that repeatedly contracts muscles by passing electrical currents through electrodes contacting the affected body area.

(b) Classification. Class II (performance standards).

Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation

Page Type
Product Code
Definition
Used for muscle stimulation for rehabilitation. Device repeatedly contracts muscles by passing pulsed electrical current through cutaneous electrodes contacting the affected body area. Indicated for use as an adjunctive therapy in rehabilitation for medical purposes such as relaxation of muscle spasm, prevention or retardation of disuse atrophy, increasing local blood circulation, muscle re-education, maintaining or increasing range of motion, and immediate post-surgical stimulation of calf muscles to prevent venous thrombosis.
Physical State
Electrical stimulation unit with leads and cutaneous electrodes
Technical Method
Stimulation of muscles using electrical current applied to electrodes on a patient's skin
Target Area
Electrodes are placed on the skin overlying the muscle or motor nerve to be stimulated
Regulation Medical Specialty
Physical Medicine
Review Panel
Physical Medicine
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
890.5850
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Third Party Eligible

CFR § 890.5850 Powered muscle stimulator

§ 890.5850 Powered muscle stimulator.

(a) Identification. A powered muscle stimulator is an electrically powered device intended for medical purposes that repeatedly contracts muscles by passing electrical currents through electrodes contacting the affected body area.

(b) Classification. Class II (performance standards).