Subpart B—Physical Medicine Diagnostic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
MOC
Cushion, Flotation, Therapeutic
2
Product Code
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
2
Product Code
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
2
Product Code
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
2
Product Code
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
2
Product Code
BXB
Exerciser, Powered
1
Product Code
EGJ
Device, Iontophoresis, Other Uses
2
Product Code
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
IKW
Utensil, Homemaking
1
Product Code
IKX
Aid, Transfer
1
Product Code
IKZ
Bed, Patient Rotation, Powered
2
Product Code
ILC
Utensil, Eating
1
Product Code
ILD
Adaptor, Dressing
1
Product Code
ILJ
Bath, Hydro-Massage
2
Product Code
ILK
Transport, Patient, Powered
2
Product Code
ILM
Bath, Sitz, Powered
2
Product Code
ILO
Pack, Hot Or Cold, Water Circulating
2
Product Code
ILS
Adaptor, Hygiene
1
Product Code
ILT
Adaptor, Recreational
1
Product Code
ILW
Adaptor, Grooming
1
Product Code
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
2
Product Code
ILY
Lamp, Infrared, Therapeutic Heating
2
Product Code
ILZ
Accessories, Traction
1
Product Code
IMA
Pack, Heat, Moist
1
Product Code
IMB
Cabinet, Moist Steam
2
Product Code
IMC
Bath, Paraffin
2
Product Code
IMD
Pack, Hot Or Cold, Disposable
1
Product Code
IME
Pack, Hot Or Cold, Reusable
1
Product Code
IMF
Unit, Chilling
1
Product Code
INX
Bed, Air Fluidized
2
Product Code
INY
Bed, Patient Rotation, Manual
1
Product Code
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
IOB
Lamp, Infrared, Non Heating
2
Product Code
IOD
Components, Exercise
1
Product Code
IOE
Bars, Parallel, Exercise
1
Product Code
IOG
Treadmill, Mechanical
1
Product Code
IOL
Treadmill, Powered
1
Product Code
ION
Exerciser, Non-Measuring
1
Product Code
IOQ
Bed, Flotation Therapy, Powered
2
Product Code
IPF
Stimulator, Muscle, Powered
2
Product Code
IRN
Device, Warning, Overload, External Limb, Powered
2
Product Code
IRO
Vibrator, Therapeutic
1
Product Code
IRP
Massager, Powered Inflatable Tube
2
Product Code
K
25
1662
Air Compression Therapy Device (ST-504); Air Compression Therapy Device (ST-505); Air Compression Therapy Device (ST-506); Air Compression Therapy Device (ST-507)
2
Cleared 510(K)
K
25
1531
AIR COMPRESSION BOOTS 1018195,1018196
2
Cleared 510(K)
K
25
3150
Cryon-X Cold Compression
2
Cleared 510(K)
K
25
1905
Normatec Elite Hip
2
Cleared 510(K)
K
25
1623
Air Compression Therapy Device (K1002/K1006/K1007/K1008/K1061)
2
Cleared 510(K)
K
25
0244
Compression Therapy Device (LGT-2210DS)
2
Cleared 510(K)
K
24
2615
Intermittent pressure compression system (Compression Pump PT1005A; Leg Compression Cuffs; L-1001S, L-1001L, L-1001XL, L-1001XXL, L-1001XXXL)
2
Cleared 510(K)
K
24
2754
ZT Clinic (MG675A); ZT Cube (ZC3) (MG465A); Z-ONE (MG455A)
2
Cleared 510(K)
K
25
0046
Air Compression Leg Massager (UM605, UM606, UM607, UM608,UM609,UM610, UM611, UM617)
2
Cleared 510(K)
K
24
2140
Air Compression Leg Massager (K-705)
2
Cleared 510(K)
K
24
3206
Air compression massager (ACM-PLUS-A1, ACM-PLUS-A2, ACM-PLUS-A3, ACM-PLUS-A4, ACM-PLUS-A5, ACM-PLUS-A6)
2
Cleared 510(K)
K
24
3572
Game Ready system (550500-04); Game Ready Control Unit (550550-04); Game Ready Full Leg Boot Wrap - Medium (590923-04); Game Ready Full Leg Boot Wrap - Large (590922-04); Game Ready C-T Spine Wrap (590502-04); Game Ready Half Leg Boot (590906-04); Game Ready Back Wrap (590500-04); Game Ready Hand/Wrist Wrap (590811-04); Game Ready Flexed Elbow Wrap (590903-04); Game Ready Straight Elbow Wrap (590200-04); Game Ready Shoulder Wrap, Medium, Right (590422-04); Game Ready Shoulder Wrap, La
2
Cleared 510(K)
K
24
3791
Air Pressure Therapy System
2
Cleared 510(K)
K
24
3177
SACS PRO
2
Cleared 510(K)
K
23
2965
Leg Massager (Models:RP-ALM070H, RP-ALM071H)
2
Cleared 510(K)
K
24
3320
Air Pressure Therapy System (VU-IPC04B)
2
Cleared 510(K)
K
24
2940
Xrecovery (XR-001)
2
Cleared 510(K)
K
24
1446
Air Compression Massager (ACM-A1, ACM-A2, ACM-A3, ACM-A4)
2
Cleared 510(K)
K
24
0373
Air compression Leg Massager (MM0520, MM0521, MM0522)
2
Cleared 510(K)
K
24
1256
JetBoots PRO Plus
2
Cleared 510(K)
K
24
0981
Air compression leg massager
2
Cleared 510(K)
K
23
3238
Air Pressure Therapy System (Model:VU-IPC4M)
2
Cleared 510(K)
K
24
0986
Cold Compression
2
Cleared 510(K)
K
24
0122
Normatec Elite
2
Cleared 510(K)
K
23
0524
Cold Compression Wrap Pro
2
Cleared 510(K)
K
22
3729
FLOWpresso
2
Cleared 510(K)
K
23
3536
Air Compression Recovery System
2
Cleared 510(K)
K
22
3541
Cold/Hot Compression
2
Cleared 510(K)
K
23
0500
Air Compression Therapy Recovery System (model: MF-AWI, MF-AWI.LED.A-801, MF-AWI.LED.B-801, MF-AWI.OLED.A-601, MF-AWI.LED.A-601, MF-AWI.LED.B-601, MF-AWI.OLED.A-401, MF-AWI.LED.A-401, MF-AWI.LED.B-401)
2
Cleared 510(K)
K
23
1912
Therm-X
2
Cleared 510(K)
K
23
1437
LF900
2
Cleared 510(K)
K
23
0385
Ballancer Platinum (1222)
2
Cleared 510(K)
K
22
2991
Air Compression Leg Massager (model: EMK-701)
2
Cleared 510(K)
K
22
3464
Leg and Foot Air Wave Pressure Therapy Device
2
Cleared 510(K)
K
22
2136
Cryo-Thermo Compression Device (FGK002)
2
Cleared 510(K)
K
22
2924
Leg Massager RF-ALM070
2
Cleared 510(K)
K
22
2949
Air Compression Leg Massager (Model: LY-670D)
2
Cleared 510(K)
K
22
1862
YY-A02-B Overlapped Compression Therapy
2
Cleared 510(K)
K
22
2669
Cryopush Cold Compression Device
2
Cleared 510(K)
K
22
3164
Aquilo Sports CCT1500 System
2
Cleared 510(K)
K
22
2206
Air Compression Leg Massager (Models: S9036C, S9036B and S9036A)
2
Cleared 510(K)
K
20
1730
Powered Inflatable Tube Massager - SLIM UP DRAIN
2
Cleared 510(K)
K
22
1666
Normatec Go
2
Cleared 510(K)
K
21
3745
Air Compression Therapy Device, model: ST-502
2
Cleared 510(K)
K
21
1850
Air Compression Leg Massager (model: FE-7204B)
2
Cleared 510(K)
K
22
0217
Normatec 3
2
Cleared 510(K)
K
21
2935
Air Pressure Foot Massager
2
Cleared 510(K)
K
21
3533
Sequential Circulators SC-1004-DL, SC-1008-DL, SC-2004-DL, SC-2008-DL, SC-4004-DL, SC-4008-DL
2
Cleared 510(K)
K
21
2713
Air compression leg massager HY-1117A
2
Cleared 510(K)
K
21
2169
Air compression therapy system FO3002
2
Cleared 510(K)
K
21
3000
Air Compression Massager (Model LF-FT003)
2
Cleared 510(K)
K
21
1745
RecoveryAir PRO
2
Cleared 510(K)
K
21
1283
Compressible Limb and Circulation Therapy System, Model POWER-Q2300
2
Cleared 510(K)
K
21
2491
Air Relax Pro Model AR-4.0
2
Cleared 510(K)
K
20
2395
SP-1000, SP-2000
2
Cleared 510(K)
K
21
0913
V12 PRO
2
Cleared 510(K)
K
20
3498
LX9max
2
Cleared 510(K)
K
20
3019
LF900
2
Cleared 510(K)
K
20
1935
Air Pressure Therapy System
2
Cleared 510(K)
K
21
0281
Fist Assist Devices Model FA-1
2
Cleared 510(K)
K
21
1460
Air Relax Plus Model AR-3.0
2
Cleared 510(K)
K
21
0967
Air Pressure Therapy System: VU-IPC06
2
Cleared 510(K)
K
20
1982
Air compression therapy system FO-3001; Air compression therapy system FO-3008
2
Cleared 510(K)
K
20
0660
Compressible Limb and Circulation Therapy System
2
Cleared 510(K)
K
20
2693
NeoWave Pain Relief and Recovery System, Model# T16-2020
2
Cleared 510(K)
K
19
1441
Air Relax, Compressible Limb Sleeve System (Model: AR-1.0, AR-2.0)
2
Cleared 510(K)
K
21
0240
Air Compression Therapy Device, model HW6007
2
Cleared 510(K)
K
19
3079
ICE COMPRESSION FIRST, DUO, & MOOVE Systems
2
Cleared 510(K)
K
20
3552
Rapid Reboot
2
Cleared 510(K)
K
20
1694
Air Compression Therapy Device
2
Cleared 510(K)
K
20
2044
Powerpress Recovery Unit
2
Cleared 510(K)
K
20
1645
Massage Compression Boots
2
Cleared 510(K)
K
20
0351
PlasmaFlight
2
Cleared 510(K)
K
19
2466
Air Compression Therapy System
2
Cleared 510(K)
K
19
3354
Air Compression Therapy Device
2
Cleared 510(K)
K
19
2358
Pressure Therapy System PT1003
2
Cleared 510(K)
K
19
3550
Therm-X
2
Cleared 510(K)
K
19
2607
LiteWalk
2
Cleared 510(K)
K
19
2114
Game Ready GRPro 2.1 System
2
Cleared 510(K)
K
19
1862
Compression Therapy Device Model LGT-2200SP
2
Cleared 510(K)
K
19
2252
ProPerformance Recovery System
2
Cleared 510(K)
K
17
3158
Air Relax
2
Cleared 510(K)
K
19
0493
Recovery Pump, 737R (RPX)
2
Cleared 510(K)
K
19
0854
Therm-X
2
Cleared 510(K)
K
19
0015
Ballancer Gold, 1212
2
Cleared 510(K)
K
18
3702
Polar Care Wave
2
Cleared 510(K)
K
18
1409
Pressure Therapy System PT1003
2
Cleared 510(K)
K
18
3169
Pulse 2.0, Pulse Pro 2.0
2
Cleared 510(K)
K
18
2668
Rapid Reboot Compression Therapy System
2
Cleared 510(K)
K
18
1149
Therm-X Pro, Therm-X AT, Therm-X Pro Athlete
2
Cleared 510(K)
K
17
1685
Med4 Elite
2
Cleared 510(K)
K
16
1907
Pressure Therapy System
2
Cleared 510(K)
K
16
3280
RP Lite 760R
2
Cleared 510(K)
K
16
0178
Lympha-Flow(LF1200)
2
Cleared 510(K)
K
16
0608
NormaTec Pulse and NormaTec Pulse Pro
2
Cleared 510(K)
K
15
0269
Ballancer 505 System, Model 1201-AC
2
Cleared 510(K)
K
15
0033
Air Compressible Limb Therapy System
2
Cleared 510(K)
K
14
3197
Nice1
2
Cleared 510(K)
K
14
0519
RECOVERY PUMP 737R
2
Cleared 510(K)
K
13
3483
PORTABLE THERAPEUTIX SQUID ACTIVE COLD COMPRESSION DEVICE AND COLD PACK FOR OTC USE
2
Cleared 510(K)
K
13
0385
COMPRESSIBLE LIMB SLEEVE SYSTEM
2
Cleared 510(K)
K
12
2112
2004-OC MASSAGE SYSTEM, 2008-OC MASSAGE SYSTEM
2
Cleared 510(K)
K
12
3829
PORTABLE THERAPEUTIX SQUID ACTIVE COLD COMPRESSION DEVICE AND COLD PACK
2
Cleared 510(K)
K
12
2154
POWERPLAY MUSCLE MASSAGER
2
Cleared 510(K)
K
12
0166
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM
2
Cleared 510(K)
K
11
3275
COMPRESSIBLE LIMB THERAPY SYSTEM
2
Cleared 510(K)
K
11
2441
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM
2
Cleared 510(K)
K
11
2890
NORMATEC MVP
2
Cleared 510(K)
K
11
2479
DSJ MASSAGER
2
Cleared 510(K)
K
10
2320
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM MODEL LX7(V7)
2
Cleared 510(K)
K
10
2319
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM MODEL WIC-2008
2
Cleared 510(K)
K
10
0656
COMPRESSIBLE LIMB THERAPY SYSTEM MODEL WHF-324 (POWER-Q1000 PLUS)
2
Cleared 510(K)
K
09
2435
VERSEO AIR PRESSURE MASSAGER
2
Cleared 510(K)
K
08
0134
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM, MODEL WHF-314 (POWER-Q1000)
2
Cleared 510(K)
K
07
1596
POTABLE AIR MASSAGER PUTIFINO, MODEL AM-7
2
Cleared 510(K)
K
07
2620
GAME READY CLASSIC SYSTEM, MODEL 550550
2
Cleared 510(K)
K
07
1050
GAME READY PROFESSIONAL THERAPY SYSTEM, MODEL 550100, GAME READY PRE-PROGRAMMED PROFESSIONAL THERAPY SYSTEM
2
Cleared 510(K)
K
04
0905
WELLNESS/JOLIVETE
2
Cleared 510(K)
K
03
2505
AIR PRESS MASSAGER
2
Cleared 510(K)
K
03
0437
RELAXOR PERFECT TOUCH AIR MASSAGING SYSTEM
2
Cleared 510(K)
K
01
3061
BIOTOUCH MASSAGE THERAPY SYSTEM
2
Cleared 510(K)
K
00
3909
PROACT 1
2
Cleared 510(K)
K
00
0655
PPCID- PNEUMATIC PERIPHERAL CIRCULATION IMPROVEMENT (FOOTREST) DEVICE
2
Cleared 510(K)
K
99
4057
SLENDAIR 4000 COMPRESSION SYSTEM
2
Cleared 510(K)
K
99
1921
INTERMITTENT COMPRESSION BOOT FOR OTC
2
Cleared 510(K)
K
97
4395
ATLANT'S
2
Cleared 510(K)
K
96
4957
INTERMITTENT COMPRESSOR SYSTEM
2
Cleared 510(K)
K
96
1426
BIO BOOST
2
Cleared 510(K)
K
95
3516
MEDCOMP MC 5 GRADIENT SEQUENTIAL PUMP
2
Cleared 510(K)
K
95
1769
CRYOPRESS
2
Cleared 510(K)
K
91
5637
TALLEY TM500 SEQUENTIAL MULTICOM COMPRESSION SYST.
2
Cleared 510(K)
K
91
5638
TALLEY TM200 INTERMTTENT COMPRESSION UNIT
2
Cleared 510(K)
K
91
5092
TALLEY TM300 SEQUENTIAL MULTICOM COMPRESSION SYST
2
Cleared 510(K)
K
91
4774
MULTIPULSE SEQUENTIAL COMPRESSION UNIT
2
Cleared 510(K)
K
91
4142
HEMO-PULSE 2000
2
Cleared 510(K)
K
91
2004
SHEPARD CRYOPRESS/CAMP MULTI-TEMP SPORT PUMPS
2
Cleared 510(K)
K
90
1022
POWERED INFLATABLE TUBE MASSAGER, SPORT-MED
2
Cleared 510(K)
K
89
3950
VENTIPRESS 24 AND 14 PRESSURE VENTILATOR
2
Cleared 510(K)
K
87
4688
FLOWTRON AC200/2
2
Cleared 510(K)
K
86
0632
EBI HAND MASSAGING PUMP (HMP)
2
Cleared 510(K)
K
85
2264
EBI FOOT MASSAGING PUMP
2
Cleared 510(K)
K
83
4507
HYDROPULSE(GROSSAN);INFLAT TUBE MASS
2
Cleared 510(K)
K
83
2920
INTERMITTENT COMPRESSION PUMPS
2
Cleared 510(K)
K
82
1920
I.C.E. BOX
2
Cleared 510(K)
K
78
1964
COMPRESSION DEVICES, LIMB
2
Cleared 510(K)
K
78
0710
AIR MASSAGE SYSTEM
2
Cleared 510(K)
IRQ
Unit, Heating, Powered
1
Product Code
IRR
Bars, Parallel, Powered
1
Product Code
IRS
Head Halter, Traction
1
Product Code
IRT
Pad, Heating, Powered
2
Product Code
ISA
Massager, Therapeutic, Electric
1
Product Code
ISD
Exerciser, Measuring
2
Product Code
ITH
Equipment, Traction, Powered
2
Product Code
JFA
Exerciser, Finger, Powered
1
Product Code
JFB
Table, Physical Therapy, Multi Function
2
Product Code
KNL
Board, Scooter, Prone
1
Product Code
KNM
Device, Pressure Applying
1
Product Code
KTB
Device, Iontophoresis, Specific Uses
2
Product Code
KTC
Bath, Sitz, Nonpowered
1
Product Code
LBG
Device, Fluidized Therapy, Dry Heat
2
Product Code
LSB
Unit, Fluidotherapy
2
Product Code
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
LXJ
Interactive Rehabilitation Exercise Devices
2
Product Code
LYG
Massager, Therapeutic, Manual
1
Product Code
MPO
Infant Heel Warmer (Chemical Heat Pack)
1
Product Code
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
2
Product Code
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
2
Product Code
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
2
Product Code
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
2
Product Code
OMW
Adhesive Backed Thermal Skin Patches
1
Product Code
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
2
Product Code
PCD
Powered Stairway Chair Lift
2
Product Code
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
2
Product Code
PHW
Cold Pack And Vibrating Massager
1
Product Code
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
1
Product Code
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
2
Product Code
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
2
Product Code
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
2
Product Code
QTC
Adult Portable Bed Rails For Medical Purposes
1
Product Code
SGT
Electromagnetic Stimulator For Healthy Muscle Stimulation
2
Product Code
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
IRP
/
K192466
View Source
Air Compression Therapy System
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K192466
510(k) Type
Traditional
Applicant
Shenzhen Lifotronic Technology Co., Ltd.
Country
China
FDA Decision
Substantially Equivalent
Decision Date
6/22/2020
Days to Decision
287 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
Subpart D—Physical Medicine Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
MOC
Cushion, Flotation, Therapeutic
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
BXB
Exerciser, Powered
EGJ
Device, Iontophoresis, Other Uses
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
IKW
Utensil, Homemaking
IKX
Aid, Transfer
IKZ
Bed, Patient Rotation, Powered
ILC
Utensil, Eating
ILD
Adaptor, Dressing
ILJ
Bath, Hydro-Massage
ILK
Transport, Patient, Powered
ILM
Bath, Sitz, Powered
ILO
Pack, Hot Or Cold, Water Circulating
ILS
Adaptor, Hygiene
ILT
Adaptor, Recreational
ILW
Adaptor, Grooming
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
ILY
Lamp, Infrared, Therapeutic Heating
ILZ
Accessories, Traction
IMA
Pack, Heat, Moist
IMB
Cabinet, Moist Steam
IMC
Bath, Paraffin
IMD
Pack, Hot Or Cold, Disposable
IME
Pack, Hot Or Cold, Reusable
IMF
Unit, Chilling
INX
Bed, Air Fluidized
INY
Bed, Patient Rotation, Manual
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
IOB
Lamp, Infrared, Non Heating
IOD
Components, Exercise
IOE
Bars, Parallel, Exercise
IOG
Treadmill, Mechanical
IOL
Treadmill, Powered
ION
Exerciser, Non-Measuring
IOQ
Bed, Flotation Therapy, Powered
IPF
Stimulator, Muscle, Powered
IRN
Device, Warning, Overload, External Limb, Powered
IRO
Vibrator, Therapeutic
IRP
Massager, Powered Inflatable Tube
K
25
1662
Air Compression Therapy Device (ST-504); Air Compression Therapy Device (ST-505); Air Compression Therapy Device (ST-506); Air Compression Therapy Device (ST-507)
K
25
1531
AIR COMPRESSION BOOTS 1018195,1018196
K
25
3150
Cryon-X Cold Compression
K
25
1905
Normatec Elite Hip
K
25
1623
Air Compression Therapy Device (K1002/K1006/K1007/K1008/K1061)
K
25
0244
Compression Therapy Device (LGT-2210DS)
K
24
2615
Intermittent pressure compression system (Compression Pump PT1005A; Leg Compression Cuffs; L-1001S, L-1001L, L-1001XL, L-1001XXL, L-1001XXXL)
K
24
2754
ZT Clinic (MG675A); ZT Cube (ZC3) (MG465A); Z-ONE (MG455A)
K
25
0046
Air Compression Leg Massager (UM605, UM606, UM607, UM608,UM609,UM610, UM611, UM617)
K
24
2140
Air Compression Leg Massager (K-705)
K
24
3206
Air compression massager (ACM-PLUS-A1, ACM-PLUS-A2, ACM-PLUS-A3, ACM-PLUS-A4, ACM-PLUS-A5, ACM-PLUS-A6)
K
24
3572
Game Ready system (550500-04); Game Ready Control Unit (550550-04); Game Ready Full Leg Boot Wrap - Medium (590923-04); Game Ready Full Leg Boot Wrap - Large (590922-04); Game Ready C-T Spine Wrap (590502-04); Game Ready Half Leg Boot (590906-04); Game Ready Back Wrap (590500-04); Game Ready Hand/Wrist Wrap (590811-04); Game Ready Flexed Elbow Wrap (590903-04); Game Ready Straight Elbow Wrap (590200-04); Game Ready Shoulder Wrap, Medium, Right (590422-04); Game Ready Shoulder Wrap, La
K
24
3791
Air Pressure Therapy System
K
24
3177
SACS PRO
K
23
2965
Leg Massager (Models:RP-ALM070H, RP-ALM071H)
K
24
3320
Air Pressure Therapy System (VU-IPC04B)
K
24
2940
Xrecovery (XR-001)
K
24
1446
Air Compression Massager (ACM-A1, ACM-A2, ACM-A3, ACM-A4)
K
24
0373
Air compression Leg Massager (MM0520, MM0521, MM0522)
K
24
1256
JetBoots PRO Plus
K
24
0981
Air compression leg massager
K
23
3238
Air Pressure Therapy System (Model:VU-IPC4M)
K
24
0986
Cold Compression
K
24
0122
Normatec Elite
K
23
0524
Cold Compression Wrap Pro
K
22
3729
FLOWpresso
K
23
3536
Air Compression Recovery System
K
22
3541
Cold/Hot Compression
K
23
0500
Air Compression Therapy Recovery System (model: MF-AWI, MF-AWI.LED.A-801, MF-AWI.LED.B-801, MF-AWI.OLED.A-601, MF-AWI.LED.A-601, MF-AWI.LED.B-601, MF-AWI.OLED.A-401, MF-AWI.LED.A-401, MF-AWI.LED.B-401)
K
23
1912
Therm-X
K
23
1437
LF900
K
23
0385
Ballancer Platinum (1222)
K
22
2991
Air Compression Leg Massager (model: EMK-701)
K
22
3464
Leg and Foot Air Wave Pressure Therapy Device
K
22
2136
Cryo-Thermo Compression Device (FGK002)
K
22
2924
Leg Massager RF-ALM070
K
22
2949
Air Compression Leg Massager (Model: LY-670D)
K
22
1862
YY-A02-B Overlapped Compression Therapy
K
22
2669
Cryopush Cold Compression Device
K
22
3164
Aquilo Sports CCT1500 System
K
22
2206
Air Compression Leg Massager (Models: S9036C, S9036B and S9036A)
K
20
1730
Powered Inflatable Tube Massager - SLIM UP DRAIN
K
22
1666
Normatec Go
K
21
3745
Air Compression Therapy Device, model: ST-502
K
21
1850
Air Compression Leg Massager (model: FE-7204B)
K
22
0217
Normatec 3
K
21
2935
Air Pressure Foot Massager
K
21
3533
Sequential Circulators SC-1004-DL, SC-1008-DL, SC-2004-DL, SC-2008-DL, SC-4004-DL, SC-4008-DL
K
21
2713
Air compression leg massager HY-1117A
K
21
2169
Air compression therapy system FO3002
K
21
3000
Air Compression Massager (Model LF-FT003)
K
21
1745
RecoveryAir PRO
K
21
1283
Compressible Limb and Circulation Therapy System, Model POWER-Q2300
K
21
2491
Air Relax Pro Model AR-4.0
K
20
2395
SP-1000, SP-2000
K
21
0913
V12 PRO
K
20
3498
LX9max
K
20
3019
LF900
K
20
1935
Air Pressure Therapy System
K
21
0281
Fist Assist Devices Model FA-1
K
21
1460
Air Relax Plus Model AR-3.0
K
21
0967
Air Pressure Therapy System: VU-IPC06
K
20
1982
Air compression therapy system FO-3001; Air compression therapy system FO-3008
K
20
0660
Compressible Limb and Circulation Therapy System
K
20
2693
NeoWave Pain Relief and Recovery System, Model# T16-2020
K
19
1441
Air Relax, Compressible Limb Sleeve System (Model: AR-1.0, AR-2.0)
K
21
0240
Air Compression Therapy Device, model HW6007
K
19
3079
ICE COMPRESSION FIRST, DUO, & MOOVE Systems
K
20
3552
Rapid Reboot
K
20
1694
Air Compression Therapy Device
K
20
2044
Powerpress Recovery Unit
K
20
1645
Massage Compression Boots
K
20
0351
PlasmaFlight
K
19
2466
Air Compression Therapy System
K
19
3354
Air Compression Therapy Device
K
19
2358
Pressure Therapy System PT1003
K
19
3550
Therm-X
K
19
2607
LiteWalk
K
19
2114
Game Ready GRPro 2.1 System
K
19
1862
Compression Therapy Device Model LGT-2200SP
K
19
2252
ProPerformance Recovery System
K
17
3158
Air Relax
K
19
0493
Recovery Pump, 737R (RPX)
K
19
0854
Therm-X
K
19
0015
Ballancer Gold, 1212
K
18
3702
Polar Care Wave
K
18
1409
Pressure Therapy System PT1003
K
18
3169
Pulse 2.0, Pulse Pro 2.0
K
18
2668
Rapid Reboot Compression Therapy System
K
18
1149
Therm-X Pro, Therm-X AT, Therm-X Pro Athlete
K
17
1685
Med4 Elite
K
16
1907
Pressure Therapy System
K
16
3280
RP Lite 760R
K
16
0178
Lympha-Flow(LF1200)
K
16
0608
NormaTec Pulse and NormaTec Pulse Pro
K
15
0269
Ballancer 505 System, Model 1201-AC
K
15
0033
Air Compressible Limb Therapy System
K
14
3197
Nice1
K
14
0519
RECOVERY PUMP 737R
K
13
3483
PORTABLE THERAPEUTIX SQUID ACTIVE COLD COMPRESSION DEVICE AND COLD PACK FOR OTC USE
K
13
0385
COMPRESSIBLE LIMB SLEEVE SYSTEM
K
12
2112
2004-OC MASSAGE SYSTEM, 2008-OC MASSAGE SYSTEM
K
12
3829
PORTABLE THERAPEUTIX SQUID ACTIVE COLD COMPRESSION DEVICE AND COLD PACK
K
12
2154
POWERPLAY MUSCLE MASSAGER
K
12
0166
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM
K
11
3275
COMPRESSIBLE LIMB THERAPY SYSTEM
K
11
2441
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM
K
11
2890
NORMATEC MVP
K
11
2479
DSJ MASSAGER
K
10
2320
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM MODEL LX7(V7)
K
10
2319
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM MODEL WIC-2008
K
10
0656
COMPRESSIBLE LIMB THERAPY SYSTEM MODEL WHF-324 (POWER-Q1000 PLUS)
K
09
2435
VERSEO AIR PRESSURE MASSAGER
K
08
0134
COMPRESSIBLE LIMB AND CIRCULATION THERAPY SYSTEM, MODEL WHF-314 (POWER-Q1000)
K
07
1596
POTABLE AIR MASSAGER PUTIFINO, MODEL AM-7
K
07
2620
GAME READY CLASSIC SYSTEM, MODEL 550550
K
07
1050
GAME READY PROFESSIONAL THERAPY SYSTEM, MODEL 550100, GAME READY PRE-PROGRAMMED PROFESSIONAL THERAPY SYSTEM
K
04
0905
WELLNESS/JOLIVETE
K
03
2505
AIR PRESS MASSAGER
K
03
0437
RELAXOR PERFECT TOUCH AIR MASSAGING SYSTEM
K
01
3061
BIOTOUCH MASSAGE THERAPY SYSTEM
K
00
3909
PROACT 1
K
00
0655
PPCID- PNEUMATIC PERIPHERAL CIRCULATION IMPROVEMENT (FOOTREST) DEVICE
K
99
4057
SLENDAIR 4000 COMPRESSION SYSTEM
K
99
1921
INTERMITTENT COMPRESSION BOOT FOR OTC
K
97
4395
ATLANT'S
K
96
4957
INTERMITTENT COMPRESSOR SYSTEM
K
96
1426
BIO BOOST
K
95
3516
MEDCOMP MC 5 GRADIENT SEQUENTIAL PUMP
K
95
1769
CRYOPRESS
K
91
5637
TALLEY TM500 SEQUENTIAL MULTICOM COMPRESSION SYST.
K
91
5638
TALLEY TM200 INTERMTTENT COMPRESSION UNIT
K
91
5092
TALLEY TM300 SEQUENTIAL MULTICOM COMPRESSION SYST
K
91
4774
MULTIPULSE SEQUENTIAL COMPRESSION UNIT
K
91
4142
HEMO-PULSE 2000
K
91
2004
SHEPARD CRYOPRESS/CAMP MULTI-TEMP SPORT PUMPS
K
90
1022
POWERED INFLATABLE TUBE MASSAGER, SPORT-MED
K
89
3950
VENTIPRESS 24 AND 14 PRESSURE VENTILATOR
K
87
4688
FLOWTRON AC200/2
K
86
0632
EBI HAND MASSAGING PUMP (HMP)
K
85
2264
EBI FOOT MASSAGING PUMP
K
83
4507
HYDROPULSE(GROSSAN);INFLAT TUBE MASS
K
83
2920
INTERMITTENT COMPRESSION PUMPS
K
82
1920
I.C.E. BOX
K
78
1964
COMPRESSION DEVICES, LIMB
K
78
0710
AIR MASSAGE SYSTEM
IRQ
Unit, Heating, Powered
IRR
Bars, Parallel, Powered
IRS
Head Halter, Traction
IRT
Pad, Heating, Powered
ISA
Massager, Therapeutic, Electric
ISD
Exerciser, Measuring
ITH
Equipment, Traction, Powered
JFA
Exerciser, Finger, Powered
JFB
Table, Physical Therapy, Multi Function
KNL
Board, Scooter, Prone
KNM
Device, Pressure Applying
KTB
Device, Iontophoresis, Specific Uses
KTC
Bath, Sitz, Nonpowered
LBG
Device, Fluidized Therapy, Dry Heat
LSB
Unit, Fluidotherapy
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
LXJ
Interactive Rehabilitation Exercise Devices
LYG
Massager, Therapeutic, Manual
MPO
Infant Heel Warmer (Chemical Heat Pack)
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
OMW
Adhesive Backed Thermal Skin Patches
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
PCD
Powered Stairway Chair Lift
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
PHW
Cold Pack And Vibrating Massager
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
QTC
Adult Portable Bed Rails For Medical Purposes
SGT
Electromagnetic Stimulator For Healthy Muscle Stimulation
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
IRP
/
K192466
View Source
Air Compression Therapy System
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K192466
510(k) Type
Traditional
Applicant
Shenzhen Lifotronic Technology Co., Ltd.
Country
China
FDA Decision
Substantially Equivalent
Decision Date
6/22/2020
Days to Decision
287 days
Submission Type