FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
MOC
Cushion, Flotation, Therapeutic
2
Product Code
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
2
Product Code
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
2
Product Code
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
2
Product Code
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
2
Product Code
BXB
Exerciser, Powered
1
Product Code
EGJ
Device, Iontophoresis, Other Uses
2
Product Code
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
IKW
Utensil, Homemaking
1
Product Code
IKX
Aid, Transfer
1
Product Code
IKZ
Bed, Patient Rotation, Powered
2
Product Code
ILC
Utensil, Eating
1
Product Code
ILD
Adaptor, Dressing
1
Product Code
ILJ
Bath, Hydro-Massage
2
Product Code
ILK
Transport, Patient, Powered
2
Product Code
ILM
Bath, Sitz, Powered
2
Product Code
ILO
Pack, Hot Or Cold, Water Circulating
2
Product Code
ILS
Adaptor, Hygiene
1
Product Code
ILT
Adaptor, Recreational
1
Product Code
ILW
Adaptor, Grooming
1
Product Code
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
2
Product Code
ILY
Lamp, Infrared, Therapeutic Heating
2
Product Code
ILZ
Accessories, Traction
1
Product Code
IMA
Pack, Heat, Moist
1
Product Code
K
15
0139
Rachel's Remedy
1
Cleared 510(K)
K
95
0701
WAHL SPORTS RELIEF HOT/COLD MASSAGER ROLLER
1
Cleared 510(K)
K
84
1698
HEAT PACK
1
Cleared 510(K)
K
83
2803
STEAM PAK MOIST HEAT
1
Cleared 510(K)
K
82
3622
INSULATED THERMOELASTOMER MITT
1
Cleared 510(K)
K
80
3177
MOIST HEAT PACK
1
Cleared 510(K)
K
79
1653
REUSABLE MOIST HEAT PACK
1
Cleared 510(K)
K
79
0904
STAO-HOTPACK
1
Cleared 510(K)
IMB
Cabinet, Moist Steam
2
Product Code
IMC
Bath, Paraffin
2
Product Code
IMD
Pack, Hot Or Cold, Disposable
1
Product Code
IME
Pack, Hot Or Cold, Reusable
1
Product Code
IMF
Unit, Chilling
1
Product Code
INX
Bed, Air Fluidized
2
Product Code
INY
Bed, Patient Rotation, Manual
1
Product Code
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
IOB
Lamp, Infrared, Non Heating
2
Product Code
IOD
Components, Exercise
1
Product Code
IOE
Bars, Parallel, Exercise
1
Product Code
IOG
Treadmill, Mechanical
1
Product Code
IOL
Treadmill, Powered
1
Product Code
ION
Exerciser, Non-Measuring
1
Product Code
IOQ
Bed, Flotation Therapy, Powered
2
Product Code
IPF
Stimulator, Muscle, Powered
2
Product Code
IRN
Device, Warning, Overload, External Limb, Powered
2
Product Code
IRO
Vibrator, Therapeutic
1
Product Code
IRP
Massager, Powered Inflatable Tube
2
Product Code
IRQ
Unit, Heating, Powered
1
Product Code
IRR
Bars, Parallel, Powered
1
Product Code
IRS
Head Halter, Traction
1
Product Code
IRT
Pad, Heating, Powered
2
Product Code
ISA
Massager, Therapeutic, Electric
1
Product Code
ISD
Exerciser, Measuring
2
Product Code
ITH
Equipment, Traction, Powered
2
Product Code
JFA
Exerciser, Finger, Powered
1
Product Code
JFB
Table, Physical Therapy, Multi Function
2
Product Code
KNL
Board, Scooter, Prone
1
Product Code
KNM
Device, Pressure Applying
1
Product Code
KTB
Device, Iontophoresis, Specific Uses
2
Product Code
KTC
Bath, Sitz, Nonpowered
1
Product Code
LBG
Device, Fluidized Therapy, Dry Heat
2
Product Code
LSB
Unit, Fluidotherapy
2
Product Code
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
LXJ
Interactive Rehabilitation Exercise Devices
2
Product Code
LYG
Massager, Therapeutic, Manual
1
Product Code
MPO
Infant Heel Warmer (Chemical Heat Pack)
1
Product Code
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
2
Product Code
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
2
Product Code
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
2
Product Code
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
2
Product Code
OMW
Adhesive Backed Thermal Skin Patches
1
Product Code
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
2
Product Code
PCD
Powered Stairway Chair Lift
2
Product Code
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
2
Product Code
PHW
Cold Pack And Vibrating Massager
1
Product Code
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
1
Product Code
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
2
Product Code
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
2
Product Code
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
2
Product Code
QTC
Adult Portable Bed Rails For Medical Purposes
1
Product Code
SGT
Electromagnetic Stimulator For Healthy Muscle Stimulation
2
Product Code
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
IMA
/
K790904
View Source
STAO-HOTPACK
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
Loading...
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
Subpart D—Physical Medicine Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
MOC
Cushion, Flotation, Therapeutic
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
BXB
Exerciser, Powered
EGJ
Device, Iontophoresis, Other Uses
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
IKW
Utensil, Homemaking
IKX
Aid, Transfer
IKZ
Bed, Patient Rotation, Powered
ILC
Utensil, Eating
ILD
Adaptor, Dressing
ILJ
Bath, Hydro-Massage
ILK
Transport, Patient, Powered
ILM
Bath, Sitz, Powered
ILO
Pack, Hot Or Cold, Water Circulating
ILS
Adaptor, Hygiene
ILT
Adaptor, Recreational
ILW
Adaptor, Grooming
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
ILY
Lamp, Infrared, Therapeutic Heating
ILZ
Accessories, Traction
IMA
Pack, Heat, Moist
K
15
0139
Rachel's Remedy
K
95
0701
WAHL SPORTS RELIEF HOT/COLD MASSAGER ROLLER
K
84
1698
HEAT PACK
K
83
2803
STEAM PAK MOIST HEAT
K
82
3622
INSULATED THERMOELASTOMER MITT
K
80
3177
MOIST HEAT PACK
K
79
1653
REUSABLE MOIST HEAT PACK
K
79
0904
STAO-HOTPACK
IMB
Cabinet, Moist Steam
IMC
Bath, Paraffin
IMD
Pack, Hot Or Cold, Disposable
IME
Pack, Hot Or Cold, Reusable
IMF
Unit, Chilling
INX
Bed, Air Fluidized
INY
Bed, Patient Rotation, Manual
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
IOB
Lamp, Infrared, Non Heating
IOD
Components, Exercise
IOE
Bars, Parallel, Exercise
IOG
Treadmill, Mechanical
IOL
Treadmill, Powered
ION
Exerciser, Non-Measuring
IOQ
Bed, Flotation Therapy, Powered
IPF
Stimulator, Muscle, Powered
IRN
Device, Warning, Overload, External Limb, Powered
IRO
Vibrator, Therapeutic
IRP
Massager, Powered Inflatable Tube
IRQ
Unit, Heating, Powered
IRR
Bars, Parallel, Powered
IRS
Head Halter, Traction
IRT
Pad, Heating, Powered
ISA
Massager, Therapeutic, Electric
ISD
Exerciser, Measuring
ITH
Equipment, Traction, Powered
JFA
Exerciser, Finger, Powered
JFB
Table, Physical Therapy, Multi Function
KNL
Board, Scooter, Prone
KNM
Device, Pressure Applying
KTB
Device, Iontophoresis, Specific Uses
KTC
Bath, Sitz, Nonpowered
LBG
Device, Fluidized Therapy, Dry Heat
LSB
Unit, Fluidotherapy
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
LXJ
Interactive Rehabilitation Exercise Devices
LYG
Massager, Therapeutic, Manual
MPO
Infant Heel Warmer (Chemical Heat Pack)
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
OMW
Adhesive Backed Thermal Skin Patches
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
PCD
Powered Stairway Chair Lift
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
PHW
Cold Pack And Vibrating Massager
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
QTC
Adult Portable Bed Rails For Medical Purposes
SGT
Electromagnetic Stimulator For Healthy Muscle Stimulation
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
IMA
/
K790904
View Source
STAO-HOTPACK
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
Loading...